Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 429
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Lancet ; 396(10252): 669-683, 2020 09 05.
Artigo em Inglês | MEDLINE | ID: mdl-32593323

RESUMO

BACKGROUND: Randomised trial data assessing the safety and efficacy of the self-expanding intra-annular Portico transcatheter aortic valve system (Abbott Structural Heart, St Paul, MN, USA) compared with any commercially available valves are needed to compare performance among designs. METHODS: In this prospective, multicentre, non-inferiority, randomised controlled trial (the Portico Re-sheathable Transcatheter Aortic Valve System US Investigational Device Exemption trial [PORTICO IDE]), high and extreme risk patients with severe symptomatic aortic stenosis were recruited from 52 medical centres experienced in performing transcatheter aortic valve replacement in the USA and Australia. Patients were eligible if they were aged 21 years or older, in New York Heart Association functional class II or higher, and had severe native aortic stenosis. Eligible patients were randomly assigned (1:1) using permuted block randomisation (block sizes of 2 and 4) and stratified by clinical investigational site, surgical risk cohort, and vascular access method, to transcatheter aortic valve replacement with the first generation Portico valve and delivery system or a commercially available valve (either an intra-annular balloon-expandable Edwards-SAPIEN, SAPIEN XT, or SAPIEN 3 valve [Edwards LifeSciences, Irvine, CA, USA]; or a supra-annular self-expanding CoreValve, Evolut-R, or Evolut-PRO valve [Medtronic, Minneapolis, MN, USA]). Investigational site staff, implanting physician, and study participant were unmasked to treatment assignment. Core laboratories and clinical event assessors were masked to treatment allocation. The primary safety endpoint was a composite of all-cause mortality, disabling stroke, life-threatening bleeding requiring transfusion, acute kidney injury requiring dialysis, or major vascular complication at 30 days. The primary efficacy endpoint was all-cause mortality or disabling stroke at 1 year. Clinical outcomes and valve performance were assessed up to 2 years after the procedure. Primary analyses were by intention to treat and the Kaplan-Meier method to estimate event rates. The non-inferiority margin was 8·5% for primary safety and 8·0% for primary efficacy endpoints. This study is registered with ClinicalTrials.gov, NCT02000115, and is ongoing. FINDINGS: Between May 30 and Sept 12, 2014, and between Aug 21, 2015, and Oct 10, 2017, with recruitment paused for 11 months by the funder, we recruited 1034 patients, of whom 750 were eligible and randomly assigned to the Portico valve group (n=381) or commercially available valve group (n=369). Mean age was 83 years (SD 7) and 395 (52·7%) patients were female. For the primary safety endpoint at 30 days, the event rate was higher in the Portico valve group than in the commercial valve group (52 [13·8%] vs 35 [9·6%]; absolute difference 4·2, 95% CI -0·4 to 8·8 [upper confidence bound {UCB} 8·1%]; pnon-inferiority=0·034, psuperiority=0·071). At 1 year, the rates of the primary efficacy endpoint were similar between the groups (55 [14·8%] in the Portico group vs 48 [13·4%] in the commercial valve group; difference 1·5%, 95% CI -3·6 to 6·5 [UCB 5·7%]; pnon-inferiority=0·0058, psuperiority=0·50). At 2 years, rates of death (80 [22·3%] vs 70 [20·2%]; p=0·40) or disabling stroke (10 [3·1%] vs 16 [5·0%]; p=0·23) were similar between groups. INTERPRETATION: The Portico valve was associated with similar rates of death or disabling stroke at 2 years compared with commercial valves, but was associated with higher rates of the primary composite safety endpoint including death at 30 days. The first-generation Portico valve and delivery system did not offer advantages over other commercially available valves. FUNDING: Abbott.


Assuntos
Estenose da Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Mortalidade , Complicações Pós-Operatórias/epidemiologia , Desenho de Prótese , Acidente Vascular Cerebral/epidemiologia , Substituição da Valva Aórtica Transcateter , Injúria Renal Aguda/epidemiologia , Injúria Renal Aguda/terapia , Idoso , Idoso de 80 Anos ou mais , Austrália , Transfusão de Sangue , Causas de Morte , Feminino , Humanos , Masculino , Complicações Pós-Operatórias/terapia , Hemorragia Pós-Operatória/epidemiologia , Hemorragia Pós-Operatória/terapia , Diálise Renal , Índice de Gravidade de Doença , Resultado do Tratamento , Estados Unidos
2.
N Engl J Med ; 374(17): 1609-20, 2016 04 28.
Artigo em Inglês | MEDLINE | ID: mdl-27040324

RESUMO

BACKGROUND: Previous trials have shown that among high-risk patients with aortic stenosis, survival rates are similar with transcatheter aortic-valve replacement (TAVR) and surgical aortic-valve replacement. We evaluated the two procedures in a randomized trial involving intermediate-risk patients. METHODS: We randomly assigned 2032 intermediate-risk patients with severe aortic stenosis, at 57 centers, to undergo either TAVR or surgical replacement. The primary end point was death from any cause or disabling stroke at 2 years. The primary hypothesis was that TAVR would not be inferior to surgical replacement. Before randomization, patients were entered into one of two cohorts on the basis of clinical and imaging findings; 76.3% of the patients were included in the transfemoral-access cohort and 23.7% in the transthoracic-access cohort. RESULTS: The rate of death from any cause or disabling stroke was similar in the TAVR group and the surgery group (P=0.001 for noninferiority). At 2 years, the Kaplan-Meier event rates were 19.3% in the TAVR group and 21.1% in the surgery group (hazard ratio in the TAVR group, 0.89; 95% confidence interval [CI], 0.73 to 1.09; P=0.25). In the transfemoral-access cohort, TAVR resulted in a lower rate of death or disabling stroke than surgery (hazard ratio, 0.79; 95% CI, 0.62 to 1.00; P=0.05), whereas in the transthoracic-access cohort, outcomes were similar in the two groups. TAVR resulted in larger aortic-valve areas than did surgery and also resulted in lower rates of acute kidney injury, severe bleeding, and new-onset atrial fibrillation; surgery resulted in fewer major vascular complications and less paravalvular aortic regurgitation. CONCLUSIONS: In intermediate-risk patients, TAVR was similar to surgical aortic-valve replacement with respect to the primary end point of death or disabling stroke. (Funded by Edwards Lifesciences; PARTNER 2 ClinicalTrials.gov number, NCT01314313.).


Assuntos
Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Feminino , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Estimativa de Kaplan-Meier , Masculino , Análise Multivariada , Complicações Pós-Operatórias/mortalidade , Fatores de Risco , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/mortalidade , Ultrassonografia
3.
Catheter Cardiovasc Interv ; 93(4): 620-625, 2019 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-30280475

RESUMO

OBJECTIVES: To compare coronary revascularization appropriateness for non-acute coronary syndrome cases under the 2017 update vs the 2012 appropriate use criteria (AUC). BACKGROUND: In 2017, the 2012 AUC for coronary revascularization were updated. We examined how applying these new 2017 updates to our previous inappropriate cases would change their appropriateness. METHODS: We identified 50 cases of patients who underwent coronary revascularization for stable ischemic heart disease who were deemed inappropriate under the 2012 AUC. Two separate physicians reviewed the cases and applied a new AUC based on the 2017 AUC. Next, if there was a change, the reason was identified. RESULTS: Average age was 64, majority being male (29; 58%). Forty-two (84%) were asymptomatic upon presentation. Most cases (27, 54%) dealt with percutaneous coronary intervention (PCI) of the right coronary artery. After applying the 2017 AUC, 34 of the 50 inappropriate failures (68%) would be changed from "inappropriate" to "may be appropriate care." Of the 34 cases, 25 (73.5%) were changed due to the new AUC no longer expecting the patient to be on ≥2 anti-angina medications prior to PCI. Of the 34 cases, eight (23.5%) were changed due to the new AUC expanding the use of non-invasive modalities. CONCLUSIONS: Applying the 2017 AUC led to a statistically higher number of cases being deemed "may be appropriate." The most common cause for the change included the change in requirement for anti-angina regimen and the expanded role of non-invasive modalities.


Assuntos
Tomada de Decisão Clínica , Definição da Elegibilidade/normas , Fidelidade a Diretrizes/normas , Isquemia Miocárdica/terapia , Seleção de Pacientes , Intervenção Coronária Percutânea/normas , Guias de Prática Clínica como Assunto/normas , Padrões de Prática Médica/normas , Idoso , Técnicas de Apoio para a Decisão , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/diagnóstico por imagem , Intervenção Coronária Percutânea/efeitos adversos , Sistema de Registros , Estudos Retrospectivos , Medição de Risco , Fatores de Risco
4.
Catheter Cardiovasc Interv ; 93(4): 707-712, 2019 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-30280469

RESUMO

OBJECTIVES: The aim of this study was to determine the prognostic value of contractile reserve (CR) at baseline in patients with low-flow, low-gradient severe aortic stenosis (AS) undergoing transcatheter aortic valve replacement (TAVR). BACKGROUND: Patients with severe AS, left ventricular dysfunction, and low transaortic gradient are at high risk for mortality during surgical aortic valve replacement (SAVR). Furthermore, patients without CR have been shown to have perioperative mortality comparable to that of patients treated medically for severe AS. METHODS: We retrospectively analyzed patients who underwent TAVR with a diagnosis of low-gradient severe AS (mean transvalvular aortic gradient < 40 mmHg, LVEF < 50%, and AVA ≤ 1.0 cm2 or AVAi ≤ 0.6 cm2 ) and who had a pre-TAVR dobutamine stress echocardiogram (DSE). Patients were stratified by the presence or absence of CR, defined as an increase in stroke volume ≥ 20% during DSE. RESULTS: From 2008 to 2016, 61 patients with low-gradient severe AS underwent TAVR and had pre-TAVR DSE. CR was present in 31 patients (51%) and absent in 30 (49%). There was no significant difference between the two groups in baseline demographics, medical history, access site, or types of valves. All-cause mortality was similar in both groups at 30 days (13% with CR vs 10% without CR, P = 1.00) and 1 year (29% with CR vs 33% without CR, HR 1.20, 95% CI 0.49-2.96, P = 0.69). CONCLUSION: In patients with low-flow, low-gradient severe AS undergoing TAVR, the presence or absence of CR does not predict all-cause mortality at 30 days or 1 year.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Hemodinâmica , Contração Miocárdica , Substituição da Valva Aórtica Transcateter/mortalidade , Disfunção Ventricular Esquerda/fisiopatologia , Função Ventricular Esquerda , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Bases de Dados Factuais , Feminino , Humanos , Masculino , Recuperação de Função Fisiológica , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Volume Sistólico , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/mortalidade
5.
N Engl J Med ; 373(21): 2015-24, 2015 11 19.
Artigo em Inglês | MEDLINE | ID: mdl-26436963

RESUMO

BACKGROUND: A finding of reduced aortic-valve leaflet motion was noted on computed tomography (CT) in a patient who had a stroke after transcatheter aortic-valve replacement (TAVR) during an ongoing clinical trial. This finding raised a concern about possible subclinical leaflet thrombosis and prompted further investigation. METHODS: We analyzed data obtained from 55 patients in a clinical trial of TAVR and from two single-center registries that included 132 patients who were undergoing either TAVR or surgical aortic-valve bioprosthesis implantation. We obtained four-dimensional, volume-rendered CT scans along with data on anticoagulation and clinical outcomes (including strokes and transient ischemic attacks [TIAs]). RESULTS: Reduced leaflet motion was noted on CT in 22 of 55 patients (40%) in the clinical trial and in 17 of 132 patients (13%) in the two registries. Reduced leaflet motion was detected among patients with multiple bioprosthesis types, including transcatheter and surgical bioprostheses. Therapeutic anticoagulation with warfarin, as compared with dual antiplatelet therapy, was associated with a decreased incidence of reduced leaflet motion (0% and 55%, respectively, P=0.01 in the clinical trial; and 0% and 29%, respectively, P=0.04 in the pooled registries). In patients who were reevaluated with follow-up CT, restoration of leaflet motion was noted in all 11 patients who were receiving anticoagulation and in 1 of 10 patients who were not receiving anticoagulation (P<0.001). There was no significant difference in the incidence of stroke or TIA between patients with reduced leaflet motion and those with normal leaflet motion in the clinical trial (2 of 22 patients and 0 of 33 patients, respectively; P=0.16), although in the pooled registries, a significant difference was detected (3 of 17 patients and 1 of 115 patients, respectively; P=0.007). CONCLUSIONS: Reduced aortic-valve leaflet motion was shown in patients with bioprosthetic aortic valves. The condition resolved with therapeutic anticoagulation. The effect of this finding on clinical outcomes including stroke needs further investigation. (Funded by St. Jude Medical and Cedars-Sinai Heart Institute; Portico-IDE ClinicalTrials.gov number, NCT02000115; SAVORY registry, NCT02426307; and RESOLVE registry, NCT02318342.).


Assuntos
Anticoagulantes/uso terapêutico , Valva Aórtica/fisiopatologia , Bioprótese/efeitos adversos , Doenças das Valvas Cardíacas/etiologia , Próteses Valvulares Cardíacas/efeitos adversos , Trombose/etiologia , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Feminino , Tomografia Computadorizada Quadridimensional , Humanos , Ataque Isquêmico Transitório/etiologia , Masculino , Sistema de Registros , Acidente Vascular Cerebral/etiologia
6.
Am Heart J ; 200: 11-16, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29898837

RESUMO

BACKGROUND: The impact of frailty assessment on outcomes in patients undergoing transcatheter aortic valve replacement (TAVR) remains unclear. Our aim was to evaluate the individual effect of each frailty test and the utility of an additive frailty index score on short- and long-term survival following TAVR. METHODS: Retrospective analysis of consecutive TAVR patients for whom a complete set of frailty tests was obtained: algorithm defined grip strength and 5-m walking tests, body mass index <20 kg/m2, Katz activities of daily living ≤4/6, serum albumin <3.5 g/dL. Frailty status was defined as having 3 or more positive frailty tests. Included were 498 patients with a mean age of 82±8 years. RESULTS: Frailty status, observed in 266 (53%) patients, was associated with both 30-day and 1-year mortality (6% vs. 2%, P=.016; 20% vs. 9%, P<.001; within the respective frailty groups). As compared to 0-2 frailty criteria, a higher frailty index score was associated with increased risk of death at 1 year (OR 2.23; 95% CI 1.14-4.34; P=.019 and OR 3.30; 95% CI 1.36-8.00; P=.008 for 3 and 4-5 frailty criteria met, respectively). In Cox regression analysis, frailty status was correlated with 1-year mortality (HR=2.2; 95%CI 1.25-3.96; P=.007), and a higher frailty index was associated with increased mortality risk (HR=2.0; 95% CI 1.08-3.7; P=.027; and HR=3.07; 95% CI 1.4-6.7; P=.005; for any 3, and 4-5 frailty criteria, respectively). CONCLUSIONS: Frailty status and a higher frailty index score were associated with increased 1-year mortality risk following TAVR.


Assuntos
Fragilidade/diagnóstico , Avaliação Geriátrica/métodos , Medição de Risco/métodos , Substituição da Valva Aórtica Transcateter/mortalidade , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/cirurgia , Índice de Massa Corporal , Feminino , Força da Mão , Humanos , Masculino , Mortalidade , Cuidados Pré-Operatórios/métodos , Projetos de Pesquisa , Estudos Retrospectivos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/métodos , Estados Unidos/epidemiologia , Teste de Caminhada/métodos
7.
Am Heart J ; 184: 141-147, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-28224928

RESUMO

BACKGROUND: Right ventricular (RV) dysfunction was shown to be associated with adverse outcomes in a variety of cardiac patients and is considered a risk factor for adverse outcome according to the updated Valve Academic Research Consortium criteria. OBJECTIVE: Our goal was to assess the impact of RV function at baseline on 1-year mortality among patients with severe aortic stenosis (AS) undergoing transcatheter aortic valve replacement (TAVR). METHODS: All patients with severe AS treated with TAVR from May 2007 to March 2015 at our center were included in the present study, and baseline and procedural characteristics were recorded for each patient. The patients were categorized according to RV function at baseline as assessed by current guidelines, and a comparison of mortality rates up to 1 year was performed. RESULTS: Among 650 patients, 606 had adequate echocardiogram quality and 146 (24%) had RV dysfunction. There were significant differences between the 2 groups, as patients with RV dysfunction were younger (81±9 vs 84±7 years, P=.01) and were more likely to be male (65% vs 42%, P<.001). In addition, patients with RV dysfunction had higher rates of prior myocardial infarction (26% vs 16%, P=.02) and atrial fibrillation (51% vs 39%, P=.02). Echocardiographic parameters demonstrated higher rates of left ventricular ejection fraction <40% (40% vs 18%, P<.001), tricuspid regurgitation above moderate (16% vs 9%, P=.04), and higher pulmonary artery systolic pressure (50±17 vs 44±16 mm Hg, P<.001) among patients with severe AS and RV dysfunction compared with patients with normal RV function. Despite the unfavorable cardiac function, patients with severe AS undergoing TAVR have similar functional class (P=.22) and mortality rates at 1year (27% vs 23%, log-rank P=.45). CONCLUSIONS: Patients with severe AS and RV dysfunction have similar 1-year mortality and functional class after TAVR to patients with normal RV function. The presence of RV dysfunction does not correlate with outcome in patients with severe AS.


Assuntos
Estenose da Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter , Disfunção Ventricular Direita/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/complicações , Ecocardiografia , Feminino , Humanos , Masculino , Mortalidade , Prognóstico , Estudos Prospectivos , Volume Sistólico , Resultado do Tratamento , Insuficiência da Valva Tricúspide/complicações , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/fisiopatologia , Disfunção Ventricular Direita/complicações , Disfunção Ventricular Direita/diagnóstico por imagem , Função Ventricular Direita
8.
Catheter Cardiovasc Interv ; 90(4): 673-679, 2017 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-28296039

RESUMO

BACKGROUND: Residual aortic regurgitation (AR) following transcatheter aortic valve replacement (TAVR) is associated with adverse outcome. We sought to evaluate the efficacy and safety of second CoreValve (CV) implantation to treat residual AR following the initial CV deployment. METHODS AND RESULTS: TAVR patients treated with a second CV due to moderate and above residual AR were compared to single device implantation. Valvular function parameters were compared at baseline, post procedure, and 30 days. Among 172 CV TAVR patients, 11 required a second device (6%) due to significant residual AR. The main differences between the groups were higher rates of low ejection fraction in patients with 2 CV implanted and higher annular diameter (27 [29-25] vs. 25 [26-24] mm, P = 0.03), requiring a larger device. Although two patients in the two CV group had high initial implantation, low implantation was similar between the groups. A second CV achieved adequate reduction in residual AR in six patients (55%), while an additional four patients had moderate residual AR. Only one remained with moderate to severe AR after 30 days follow-up. There were no cases of peri-procedural stroke or mortality. CONCLUSIONS: Second implantation of self-expanding valve can successfully reduce residual significant AR following initial CV implantation and should be considered as therapeutic option for this population. © 2017 Wiley Periodicals, Inc.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Feminino , Hemodinâmica , Humanos , Masculino , Desenho de Prótese , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
9.
Catheter Cardiovasc Interv ; 89(4): 640-646, 2017 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-27860277

RESUMO

OBJECTIVE: Comparison of transradial versus transfemoral access for complex percutaneous coronary intervention (PCI) with regard to both complications and long-term outcomes. BACKGROUND: Radial access has been shown to confer superior results in patients undergoing PCI, especially in patients with acute coronary syndromes. However, radial access has limitations of sheath and device size, which may increase procedure time and result in inferior outcomes. METHODS: Patients undergoing PCI for complex lesions, defined as type C according the ACC/AHA classification system, were included in this study. Propensity matching was performed to adjust for differences in baseline characteristics. Transradial patients were then compared to transfemoral patients in regard to procedural, in-hospital, and 6-month outcomes. RESULTS: Among 2142 patients with 2591 lesions treated, 1876 had femoral access and 267 had radial access. Radial access patients were more likely to be male (75% vs. 66%, P = 0.003) and less likely to present with acute myocardial infarction (27% vs. 42%, P < 0.001). Procedural characteristics demonstrated lower use of heparin in the femoral group (17% vs. 73%, P < 0.001) with similarly low use of glycoprotein inhibitors (5.6% vs. 3.4%, P = 0.14). Patients in the femoral group had higher rates of transfusions (3.7% vs. 0%, P = 0.004) and vascular complications (1.7% vs. 0%, P = 0.03). Following propensity matching, there was no difference in mid-term outcomes between radial and femoral groups. CONCLUSIONS: In patients with complex coronary lesions undergoing PCI, the radial approach demonstrates similar mid-term outcomes as the femoral approach with a potentially lower rate of complications. © 2016 Wiley Periodicals, Inc.


Assuntos
Síndrome Coronariana Aguda/cirurgia , Cateterismo Periférico/métodos , Intervenção Coronária Percutânea/métodos , Complicações Pós-Operatórias/epidemiologia , Síndrome Coronariana Aguda/diagnóstico , Idoso , Causas de Morte/tendências , Angiografia Coronária , District of Columbia/epidemiologia , Eletrocardiografia , Feminino , Artéria Femoral , Seguimentos , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Prognóstico , Artéria Radial , Estudos Retrospectivos , Fatores de Tempo
10.
Lancet ; 385(9986): 2485-91, 2015 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-25788231

RESUMO

BACKGROUND: Based on the early results of the Placement of Aortic Transcatheter Valves (PARTNER) trial, transcatheter aortic valve replacement (TAVR) is an accepted treatment for patients with severe aortic stenosis who are not suitable for surgery. However, little information is available about the late clinical outcomes in such patients. METHODS: We did this randomised controlled trial at 21 experienced valve centres in Canada, Germany, and the USA. We enrolled patients with severe symptomatic inoperable aortic stenosis and randomly assigned (1:1) them to transfemoral TAVR or to standard treatment, which often included balloon aortic valvuloplasty. Patients and their treating physicians were not masked to treatment allocation. The randomisation was done centrally, and sites learned of the assignment only after a patient had been screened, consented, and entered into the database. The primary outcome of the trial was all-cause mortality at 1 year in the intention-to-treat population, here we present the prespecified findings after 5 years. This study is registered with ClinicalTrials.gov, number NCT00530894. FINDINGS: We screened 3015 patients, of whom 358 were enrolled (mean age 83 years, Society of Thoracic Surgeons Predicted Risk of Mortality 11·7%, 54% female). 179 were assigned to TAVR treatment and 179 were assigned to standard treatment. 20 patients crossed over from the standard treatment group and ten withdrew from study, leaving only six patients at 5 years, of whom five had aortic valve replacement treatment outside of the study. The risk of all-cause mortality at 5 years was 71·8% in the TAVR group versus 93·6% in the standard treatment group (hazard ratio 0·50, 95% CI 0·39-0·65; p<0·0001). At 5 years, 42 (86%) of 49 survivors in the TAVR group had New York Heart Association class 1 or 2 symptoms compared with three (60%) of five in the standard treatment group. Echocardiography after TAVR showed durable haemodynamic benefit (aortic valve area 1·52 cm(2) at 5 years, mean gradient 10·6 mm Hg at 5 years), with no evidence of structural valve deterioration. INTERPRETATION: TAVR is more beneficial than standard treatment for treatment of inoperable aortic stenosis. TAVR should be strongly considered for patients who are not surgical candidates for aortic valve replacement to improve their survival and functional status. Appropriate selection of patients will help to maximise the benefit of TAVR and reduce mortality from severe comorbidities. FUNDING: Edwards Lifesciences.


Assuntos
Estenose da Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/mortalidade , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/epidemiologia , Estenose da Valva Aórtica/fisiopatologia , Canadá , Causas de Morte , Comorbidade , Ecocardiografia , Feminino , Seguimentos , Alemanha , Hemodinâmica , Humanos , Estimativa de Kaplan-Meier , Masculino , Medição de Risco , Acidente Vascular Cerebral/epidemiologia , Taxa de Sobrevida , Resultado do Tratamento , Estados Unidos
11.
Am Heart J ; 172: 80-7, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26856219

RESUMO

BACKGROUND: Cerebrovascular accident (CVA) and transient ischemic attack (TIA) related to percutaneous coronary intervention (PCI) are relatively rare complications, but they are associated with high morbidity and mortality. Given the evolution of both CVA risk and PCI techniques over time, this study was conducted to evaluate trends in CVA and TIA associated with PCI and to identify variables associated with neurologic events. METHODS: Consecutive patients undergoing PCI at the Washington Hospital Center between January 2002 and June 2015 were included. Prespecified data were prospectively collected, including baseline and procedural characteristics, in-hospital outcomes, and 1-year mortality. The subjects who had a CVA or TIA during or immediately after PCI were compared with those without procedure-associated CVA or TIA. RESULTS: Overall, 25,626 patients were included in the study. The mean age was 65.0 ± 12.4 years, 16,949 (65.2%) were male, and 7,436 (28.6%) were African American. From 2002 to 2015, 110 neurologic events post-PCI were diagnosed (0.43%); this included 86 CVAs (0.34%) and 24 TIAs (0.09%). The annual rate of postprocedural neurologic events was 0.42% ± 0.12%. There were significant changes in baseline risk factors over time, with increasing age, incidence of insulin-dependent diabetes, and chronic kidney disease. Patients with neurologic events were more often African American (43.6% vs 28.6%, P < .001) with prior history of CVA (24.5% vs 7.8%, P < .001), chronic renal insufficiency (26.6% vs 15.2%, P < .001), and insulin-dependent diabetes (19.1% vs 12.4%, P = .03). Acute myocardial infarction (56% vs 30.4%, P < .001) and cardiogenic shock (20.2% vs 3%, P < .001) were also more common among patients with neurologic events post-PCI. After multivariable adjustment, use of an intraaortic balloon pump was strongly associated with neurologic events (odds ratio [OR] 4.9, 95% CI 2.7-8.8, P < .001), as was prior CVA (OR 2.4, 95% CI 1.4-4.4, P = .002) and African American race (OR 2.4, 95% CI 1.5-3.9, P < .001); there was a borderline association with the use of a thrombus extraction device (OR 1.7, 95% CI 0.9-3.2, P = .09). In-hospital mortality (20.0% vs 1.5%, P < .001) and 1-year mortality (45.0% vs 7.3%, P < .001) were also much higher in patients with neurologic events. CONCLUSION: Neurologic events post-PCI are associated with markedly worse in-hospital outcomes. The incidence of CVA and TIA post-PCI, however, remained stable over the last 12 years despite an increase in risk factors for CVA.


Assuntos
Previsões , Isquemia Miocárdica/cirurgia , Intervenção Coronária Percutânea/efeitos adversos , Sistema de Registros , Acidente Vascular Cerebral/epidemiologia , Idoso , District of Columbia/epidemiologia , Feminino , Seguimentos , Mortalidade Hospitalar/tendências , Humanos , Incidência , Masculino , Razão de Chances , Prognóstico , Estudos Retrospectivos , Fatores de Risco , Acidente Vascular Cerebral/etiologia , Fatores de Tempo
12.
Am Heart J ; 173: 118-25, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26920604

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is the current standard for nonoperable and high-risk surgical patients with aortic stenosis, including those of advanced age. However, the clinical profiles, procedural characteristics, and outcomes of nonagenarians undergoing TAVR have not been thoroughly reported. METHODS: A total of 654 patients (n = 107 >90 years old and n = 547 <90 years) with severe aortic stenosis undergoing TAVR were included in this analysis. Baseline characteristics, procedural variables, and in-hospital outcomes and complications at 30 days and 12 months were analyzed. RESULTS: Overall, of the patients included, 46% were high risk and 53% inoperable. Although nonagenarians had a higher Society of Thoracic Surgeons score of 9.2 ± 4 (12.1 ± 4 vs 8.6 ± 4, P < .001), other factors were considerably lower in this group: diabetes (22% vs 36%, P = .008), hyperlipidemia (65% vs 83%, P < .001), prior coronary artery bypass (13% vs 39%, P < .001), and mean body mass index (24.5 ± 5 vs 28.1 ± 7 kg/m(2), P < .001). The correlates for 1-year mortality in nonagenarians were as follows: ≥moderate aortic insufficiency post-TAVR (hazard ratio [HR] 5.07, 95% CI 1.17-22, P = .03), pacemaker implantation after TAVR (HR 6.87, 95% CI 2.32-20.3, P = .001), and peripheral vascular disease (HR 2.35, 95% CI 1.03-5.38, P = .042). Mortality at 30 days (12.1% vs 7.1%, P = .07) and at 1 year (25% vs 21%, P = .35) was similar between groups. CONCLUSION: Nonagenarians undergoing TAVR had a healthier clinical profile compared with younger patients. Age alone should not be a discriminatory factor when screening elderly patients with aortic stenosis because even the nonagenarians are doing well when compared with the younger elderly population. Transcatheter aortic valve replacement remains a viable option for the treatment of severe symptomatic aortic stenosis for the elderly regardless of their age.


Assuntos
Estenose da Valva Aórtica/mortalidade , Diagnóstico por Imagem/métodos , Medição de Risco , Substituição da Valva Aórtica Transcateter , Fatores Etários , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Angiografia Coronária , District of Columbia/epidemiologia , Ecocardiografia , Feminino , Seguimentos , Humanos , Masculino , Prognóstico , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Taxa de Sobrevida/tendências , Fatores de Tempo , Tomografia Computadorizada por Raios X
13.
Am Heart J ; 178: 19-27, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27502848

RESUMO

BACKGROUND: The prevalence of concomitant significant mitral regurgitation (MR) in patients with severe aortic stenosis (AS) undergoing transcatheter aortic valve replacement (TAVR) ranges from 2% to 33%. The impact of significant MR on post-TAVR outcomes remains controversial. METHODS: The data from a cohort of patients with symptomatic severe AS undergoing TAVR at out institution were retrospectively analyzed. The last transthoracic echocardiogram (TTE) before the index TAVR procedure was selected as the baseline assessment of the degree of MR. The total study cohort (N = 589) was divided into 2 groups: significant ≥moderate MR (n = 68) versus nonsignificant

Assuntos
Estenose da Valva Aórtica/cirurgia , Insuficiência da Valva Mitral/epidemiologia , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/epidemiologia , Estudos de Coortes , Comorbidade , Bases de Dados Factuais , Ecocardiografia , Feminino , Humanos , Masculino , Insuficiência da Valva Mitral/diagnóstico por imagem , Mortalidade , Prognóstico , Modelos de Riscos Proporcionais , Estudos Retrospectivos , Índice de Gravidade de Doença , Análise de Sobrevida , Resultado do Tratamento
14.
Catheter Cardiovasc Interv ; 87(1): 176-82, 2016 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-26257081

RESUMO

OBJECTIVES: We sought to identify if baseline characteristic differences in patients who receive a 23 mm vs. 26 mm valve impact clinical outcomes. BACKGROUND: Transcatheter aortic valve replacement (TAVR) is currently an approved therapy for patients with severe aortic stenosis who are considered inoperable or are at high risk. METHODS: We retrospectively examined baseline characteristics and outcomes of patients receiving a 23 mm (n = 132) vs. 26 mm valve (n = 81) via the transfemoral approach. RESULTS: Gender (P < 0.01), previous coronary artery bypass surgery (P < 0.01), history of atrial fibrillation (P = 0.04), and mean Society of Thoracic Surgeons (STS) score (P < 0.01) were significantly different between groups. There were no significant differences in the rates of minor/major vascular complications (2.2 vs. 3.7%, P = 0.68 and 13.0 vs. 12.3%, P = 0.89, respectively). Bleeding complications were also comparable (major bleed 2.3 vs. 1%, P >0.99, minor bleed 19.0 vs. 22.0%, P = 0.67 and life threatening bleed 7.0 vs. 5.0%, P = 0.77). In-hospital death (6.0 vs. 5.0%, P >0.99), 30-day all-cause death (7.6 vs. 6.2%, P = 0.69), and all-cause death at 1 year (17.4 vs. 25.9%, P = 0.13) were also similar between groups. Gender, valve size, previous coronary bypass surgery and atrial fibrillation were not independently associated with mortality; however, on multivariate analysis STS score was (HR 1.11; 95% CI 1.02-1.19; P = 0.01). CONCLUSION: Patients undergoing TAVR with 23 and 26 mm valves have similar clinical outcomes despite significant differences in baseline characteristics. © 2015 Wiley Periodicals, Inc.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/métodos , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/diagnóstico , Feminino , Seguimentos , Humanos , Masculino , Desenho de Prótese , Estudos Retrospectivos , Índice de Gravidade de Doença , Tomografia Computadorizada por Raios X , Resultado do Tratamento
15.
Catheter Cardiovasc Interv ; 88(4): 516-521, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26603135

RESUMO

BACKGROUND: The influence of age upon the use of drug-eluting stents (DES) in patients aged ≥ 65 years is uncertain. The aim of this study is to investigate the impact of age increase in patients aged ≥ 65 years in the use of DES in patients undergoing percutaneous coronary intervention (PCI). METHOD: The study cohort comprised 8,598 patients ≥ 65 years of age who underwent stent implantation from April 2003 to March 2014. We defined the first DES era as the period April 2003 to July 2008 and the second DES era as the period July 2008 to March 2014. Multivariable logistic regression was performed for both eras to assess the impact of age increase and analyze independent factors associated with DES implantation. RESULTS: In the first DES era cohort, the two groups of patients differed in their risk factor profile with lower rates of male sex, diabetes, smokers, and hypercholesterolemia in those aged ≥ 75 years. There were more Caucasian and less African-Americans in this age group. Furthermore, patients aged ≥ 75 years had lower left ventricular ejection fraction (LVEF) and baseline haematocrit concentration were more likely to present with an acute myocardial infarction (MI) than stable or unstable angina and had higher rates of a previous history for congestive heart failure (CHF), chronic renal insufficiency (CRI), and peripheral vascular disease (PVD). These differences were broadly similar for patients in the second DES era except for similarities in LVEF, presentation with unstable angina, and PVD, as well as a lower rate for previous PCI. DES use was reduced with increasing age in both the first (OR=0.78; 95% CI=0.69-0.89) and second DES era (OR=0.53; 95% CI=0.47-0.58). In both eras, DES use was less likely in current smokers, patients presenting with acute MI and cardiogenic shock, and those with a previous history of CHF. CONCLUSION: In patients aged ≥ 65 years, the use of DES decreased with increasing age. This observation was apparent in both the first and second DES era. © 2015 Wiley Periodicals, Inc.


Assuntos
Envelhecimento , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Doença da Artéria Coronariana/fisiopatologia , District of Columbia , Feminino , Humanos , Modelos Logísticos , Masculino , Análise Multivariada , Razão de Chances , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Desenho de Prótese , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
16.
Catheter Cardiovasc Interv ; 88(1): 118-24, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26715505

RESUMO

BACKGROUND: Conflicting results have been reported regarding impact of body mass index (BMI) on outcome of transcatheter aortic valve replacement (TAVR) patients. This study evaluates the impact of BMI on 1 year mortality in patients undergoing TAVR via the transfemoral (TF) access. METHODS: Aortic stenosis (AS) patients undergoing TAVR via a TF access between May 2007 and December 2014 were categorized to 4 groups by BMI: low (<20), normal (20-24.9), overweight (25-30), and obese (>30). Baseline parameters were compared, and multivariate Cox proportional hazard regression models were generated to assess outcome differences. RESULTS: Among 491 severe AS TAVR patients, 43 had low BMI, 148 had normal BMI, 162 were overweight, and 138 were obese. Obese patients were younger with lower Society of Thoracic Surgeons scores and higher rates of preserved ejection fraction and diabetes. There was a higher rate of women in the BMI extremes. Aortic valve area was higher among obese patients; however, the indexed area was inversely correlated with BMI. Vascular complications and transfusions were more common in the low-BMI group, while acute kidney injury was more common in obese patients. All-cause mortality at 1 year was higher in the low-BMI group (log-rank p = 0.003) with no significant difference among normal and above-normal BMI patients. In a multivariate model, BMI <20 kg/m(2) was an independent predictor of mortality (HR = 2.45, p = 0.01). CONCLUSIONS: BMI <20 kg/m(2) should be considered a frailty marker during the screening process of severe AS TAVR patients as it is associated with higher mortality, while obesity confers similar mortality risk as normal weight. © 2015 Wiley Periodicals, Inc.


Assuntos
Estenose da Valva Aórtica/terapia , Valva Aórtica , Índice de Massa Corporal , Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca , Obesidade/complicações , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/mortalidade , Cateterismo Periférico , Distribuição de Qui-Quadrado , District of Columbia , Feminino , Artéria Femoral , Idoso Fragilizado , Avaliação Geriátrica , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Estimativa de Kaplan-Meier , Masculino , Análise Multivariada , Obesidade/diagnóstico , Obesidade/mortalidade , Modelos de Riscos Proporcionais , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento
17.
Catheter Cardiovasc Interv ; 87(1): 154-62, 2016 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-26256280

RESUMO

OBJECTIVES: To assess technical performance learning curves of teams performing transfemoral transcatheter aortic valve replacement (TF-TAVR). BACKGROUND: TF-TAVR is a new procedure for treating severe aortic stenosis. The number of cases required for procedural efficiency is unknown. METHODS: In the PARTNER-I trial, 1,521 patients underwent TF-TAVR from 4/2007-2/2012. Learning curve analysis of technical performance metrics was performed using institution-specific patient sequence number, interval between procedures, and institutional trial entry date. Learning curve characteristics were assessed using semi-parametric and parametric mixed-effects models. RESULTS: As patient sequence number increased, average procedure time decreased from 154 to 85 minutes (P < 0.0001), and fluoroscopy time from 28 to 20 minutes (P < 0.0001). Procedure time plateaued at an average of 83 minutes (range 52-140). Procedure time plateau was dynamic during the course of the trial, averaging 25 cases (range 21-52) by its end. The later institutions enrolled in the trial, the shorter the initial procedure time. During the trial, percutaneous rather than surgical access increased from 7.9% to 69%. CONCLUSIONS: Technical performance learning curves exist for TF-TAVR; procedural efficiency increased with experience, with concomitant decreases in radiation and contrast media exposure. The number of cases needed to achieve efficiency decreased progressively, with optimal procedural performance reached after approximately 25 cases for late-entering institutions. Knowledge and experience accumulated by early TF-TAVR institutions were disseminated, shortening the learning curve of late-entering institutions. Technological advances resulting from learning during the trial moved the field from initial conservative surgical cut-down to percutaneous access for most patients. © 2015 Wiley Periodicals, Inc.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Educação de Pós-Graduação em Medicina/normas , Próteses Valvulares Cardíacas , Curva de Aprendizado , Substituição da Valva Aórtica Transcateter/educação , Idoso de 80 Anos ou mais , Feminino , Artéria Femoral , Humanos , Masculino , Índice de Gravidade de Doença , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/métodos
18.
Catheter Cardiovasc Interv ; 87(1): 165-75, 2016 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-26425793

RESUMO

OBJECTIVES: To identify number of cases needed to maximize device success and minimize adverse events after transfemoral transcatheter aortic valve replacement (TF-TAVR), and determine if adverse events were linked to the technical performance learning curve. BACKGROUND: TF-TAVR is a complex procedure with an incompletely characterized learning curve for clinical outcomes. METHODS: From 4/2007-2/2012, 1521 patients underwent TF-TAVR in the PARTNER-I trial. Outcomes learning curves were defined as number of cases needed to reach a plateau for device success, adverse events, and post-procedure length of stay. Institutional variation was accounted for by mixed-model non-linear techniques, which were also used to identify contribution of the procedure time learning curve to 30-day major adverse events and length of stay. RESULTS: Eighty percent device success was achieved after 22 cases; major vascular complications fell below 5% after 70 cases and major bleeding below 10% after 25 cases. It took an average of 28 cases to achieve a consistent low risk of 30-day major adverse events, but institutions entering in the middle of the trial achieved it after about 26. The most significant correlate of 30-day major adverse events and post-procedure length of stay was procedure time (P < 0.0001). However, this association was related to patient and unmeasured variables, not the procedure time learning curve (P = 0.6). CONCLUSIONS: By end of trial, a consistent low risk of adverse events was achieved after ∼26 cases. However, these improved results were due to change in patient risk profile; outcomes were not linked to the technical performance learning curve. © 2015 Wiley Periodicals, Inc.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Educação de Pós-Graduação em Medicina/métodos , Próteses Valvulares Cardíacas , Curva de Aprendizado , Substituição da Valva Aórtica Transcateter/educação , Idoso de 80 Anos ou mais , Feminino , Artéria Femoral , Humanos , Masculino , Estudos Retrospectivos , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
19.
Circulation ; 130(17): 1483-92, 2014 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-25205802

RESUMO

BACKGROUND: The long-term outcomes of transcatheter aortic valve replacement (TAVR) in inoperable patients with severe aortic stenosis remain unknown. METHODS AND RESULTS: In the Placement of Aortic Transcatheter Valves (PARTNER) study, 358 patients were randomly assigned to TAVR or standard therapy. We report the 3-year outcomes on these patients, and the pooled outcomes for all randomly assigned inoperable patients (n=449) in PARTNER, as well, including the randomized portion of the continued access study (n=91). The 3-year mortality rate in the TAVR and standard therapy groups was 54.1% and 80.9%, respectively (P<0.001; hazard ratio, 0.53; 95% confidence interval, 0.41-0.68; P<0.001). In survivors, there was significant improvement in New York Heart Association functional class sustained at 3 years. The cumulative incidence of strokes at 3-year follow-up was 15.7% in TAVR patients versus 5.5% in patients undergoing standard therapy (hazard ratio, 2.81; 95% confidence interval, 1.26-6.26; P=0.012); however, the composite of death or strokes was significantly lower after TAVR versus standard therapy (57.4% versus 80.9%, P<0.001; hazard ratio, 0.60; 95% confidence interval, 0.46-0.77; P<0.001). Echocardiography showed a sustained increase in aortic valve area and decrease in transvalvular gradient after TAVR. Analysis of the 449 pooled randomly assigned patients (TAVR, n=220; standard therapy, n=229) demonstrated significant improvement in all-cause mortality and functional status during early and 3-year follow-up. The results of the pooled cohort were similar to the results obtained from the pivotal PARTNER trial. CONCLUSIONS: TAVR resulted in better survival and functional status in inoperable patients with severe aortic stenosis with durable hemodynamic benefit on long-term follow-up. However, high residual mortality, even in successfully treated TAVR patients, highlights the need for more strategic patient selection. CLINICAL TRIAL REGISTRATION URL: http://www.clinicaltrials.gov. Unique identifier: NCT00530894.


Assuntos
Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/terapia , Substituição da Valva Aórtica Transcateter/mortalidade , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Insuficiência da Valva Aórtica/mortalidade , Insuficiência da Valva Aórtica/terapia , Cateterismo Cardíaco , Feminino , Seguimentos , Hemodinâmica , Hemorragia/etiologia , Hemorragia/mortalidade , Humanos , Estimativa de Kaplan-Meier , Masculino , Avaliação de Resultados em Cuidados de Saúde , Readmissão do Paciente/estatística & dados numéricos , Modelos de Riscos Proporcionais , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/mortalidade , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
20.
N Engl J Med ; 366(18): 1696-704, 2012 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-22443478

RESUMO

BACKGROUND: Transcatheter aortic-valve replacement (TAVR) is the recommended therapy for patients with severe aortic stenosis who are not suitable candidates for surgery. The outcomes beyond 1 year in such patients are not known. METHODS: We randomly assigned patients to transfemoral TAVR or to standard therapy (which often included balloon aortic valvuloplasty). Data on 2-year outcomes were analyzed. RESULTS: A total of 358 patients underwent randomization at 21 centers. The rates of death at 2 years were 43.3% in the TAVR group and 68.0% in the standard-therapy group (P<0.001), and the corresponding rates of cardiac death were 31.0% and 62.4% (P<0.001). The survival advantage associated with TAVR that was seen at 1 year remained significant among patients who survived beyond the first year (hazard ratio, 0.58; 95% confidence interval [CI], 0.36 to 0.92; P=0.02 with the use of the log-rank test). The rate of stroke was higher after TAVR than with standard therapy (13.8% vs. 5.5%, P=0.01), owing, in the first 30 days, to the occurrence of more ischemic events in the TAVR group (6.7% vs. 1.7%, P=0.02) and, beyond 30 days, to the occurrence of more hemorrhagic strokes in the TAVR group (2.2% vs. 0.6%, P=0.16). At 2 years, the rate of rehospitalization was 35.0% in the TAVR group and 72.5% in the standard-therapy group (P<0.001). TAVR, as compared with standard therapy, was also associated with improved functional status (P<0.001). The data suggest that the mortality benefit after TAVR may be limited to patients who do not have extensive coexisting conditions. Echocardiographic analysis showed a sustained increase in aortic-valve area and a decrease in aortic-valve gradient, with no worsening of paravalvular aortic regurgitation. CONCLUSIONS: Among appropriately selected patients with severe aortic stenosis who were not suitable candidates for surgery, TAVR reduced the rates of death and hospitalization, with a decrease in symptoms and an improvement in valve hemodynamics that were sustained at 2 years of follow-up. The presence of extensive coexisting conditions may attenuate the survival benefit of TAVR. (Funded by Edwards Lifesciences; ClinicalTrials.gov number, NCT00530894.).


Assuntos
Estenose da Valva Aórtica/terapia , Valva Aórtica/cirurgia , Cateterismo Cardíaco , Cateterismo , Implante de Prótese de Valva Cardíaca/métodos , Anticoagulantes/efeitos adversos , Anticoagulantes/uso terapêutico , Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/mortalidade , Cateterismo Cardíaco/efeitos adversos , Doenças Cardiovasculares/etiologia , Feminino , Seguimentos , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Hospitalização/estatística & dados numéricos , Humanos , Estimativa de Kaplan-Meier , Masculino , Inibidores da Agregação Plaquetária/efeitos adversos , Inibidores da Agregação Plaquetária/uso terapêutico , Falha de Prótese , Acidente Vascular Cerebral/etiologia , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa