Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Molecules ; 24(17)2019 Aug 26.
Artigo em Inglês | MEDLINE | ID: mdl-31455031

RESUMO

Poly- and cyclophosphazenes are excellent flame retardants but currently, are not used as textile finishing agents because water-soluble and permanent washing systems are missing. Here, we demonstrate for the first time, the successful usage of a water-soluble cyclotriphosphazene derivative for textile finishing for cotton, different cotton/polyester, and cotton/polyamide blend fabrics. A durable finish was achieved using a photoinduced grafting reaction. The flame retardant properties of the various fabrics were improved with a higher limiting oxygen index, a reduced heat release rate, and an exhibition of intumescent. Furthermore, the finished textiles passed several standardized flammability tests.


Assuntos
Retardadores de Chama/síntese química , Química Verde/métodos , Compostos Organofosforados/síntese química , Microscopia Eletrônica de Varredura , Compostos Organofosforados/química , Solubilidade , Têxteis , Termogravimetria
2.
Polymers (Basel) ; 12(5)2020 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-32466250

RESUMO

Phytic acid (PA), as a natural source of phosphorus, was immobilized on cotton (CO) in a layer-by-layer (LbL) approach with polyvinylamine (PVAm) as the oppositely charged electrolyte to create a partly bio-based flame-retardant finish. PVAm was employed as a synthetic nitrogen source with the highest density of amine groups of all polymers. Vertical flame tests revealed a flame-retardant behavior with no afterflame and afterglow time for a coating of 15 bilayers (BL) containing 2% phosphorus and 1.4% nitrogen. The coating achieved a molar P:N ratio of 3:5. Microscale combustion calorimetry (MCC) analyses affirmed the flame test findings by a decrease in peak heat release rate (pkHRR) by more than 60% relative to unfinished CO. Thermogravimetric analyses (TGA) and MCC measurements exhibited a shifted CO peak to lower temperatures indicating proceeding reactions to form an isolating char on the surface. Fourier transform infrared spectroscopy (FTIR) coupled online with a TGA system, allowed the identification of a decreased amount of acrolein, methanol, carbon monoxide and formaldehyde during sample pyrolysis and a higher amount of released water. Thereby the toxicity of released volatiles was reduced. Our results prove that PA enables a different reaction by catalyzing cellulosic dehydration, which results in the formation of a protective char on the surface of the burned fabric.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa