Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Korean J Orthod ; 54(5): 274-283, 2024 Sep 25.
Artigo em Inglês | MEDLINE | ID: mdl-39128860

RESUMO

Objective: To determine the correlation between dentoskeletal parameters related to craniofacial morphology and the upper airway (UA) volume. Methods: Cone-beam computed tomography images of 106 randomly selected orthodontic patients were analyzed using NemoFab Ortho software. The dentoskeletal variables assessed were anterior facial height (AFH), posterior facial height (PFH), PFH/AFH ratio, hyoid position, maxillary width (MW), and palatal depth. The UA volume (evaluation in anatomical regions and as a whole) was also assessed using the same software. We also evaluated potential differences in UA variables between age and sex groups. The correlation between the dentoskeletal parameters and UA volume was calculated using the Pearson correlation coefficient (R). Analysis of variance and Student's t test were performed to assess differences between age and sex for UA variables. Statistical analyses were performed using SPSS software (version 26 for Windows). Results: This study found that PFH, AFH, and MW were the dentoskeletal parameters most strongly correlated with UA volume. However, the ANB angle did not show any significant correlation with UA volume. Additionally, differences in UA volumes were observed between age groups. Sex differences were found in both the "8-12" and "≥ 16" age groups for oropharyngeal and pharyngeal volumes. Conclusions: In conclusion, our findings indicate a significant correlation between UA volume and dentoskeletal parameters, particularly those related to facial height and MW.

2.
Materials (Basel) ; 15(12)2022 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-35744359

RESUMO

Friction is an intensely studied feature in orthodontics, as the sliding mechanics approach remains one of the most utilized techniques in current practice, and the question of whether self-ligating brackets produce less friction than conventional brackets still stands. The objective of this study was to compare a self-ligating system with different closing mechanisms and a conventional system with different ligating mechanisms regarding their frictional properties. Laboratory measurements were performed using an advanced materials testing machine generating tensile strength and load at maximum Load values, which were statistically analyzed and compared. These two parameters have been associated with the frictional resistance generated at the archwire-bracket slot interface. Statistically significant results were obtained when comparing the active self-ligating brackets with the passive self-ligating (tensile strength mean 1.953, SD 0.4231; load at maximum moad mean 6.000, SD 1.3000) and conventional brackets (tensile strength mean 1.953, SD 0.4231; load at maximum load mean 6.000, SD 1.3000), as well as when comparing the passive self-ligating brackets with the conventional brackets (tensile strength mean 1.708, SD 0.8628; load at maximum load mean 5.254, SD 2.645). The active self-ligating brackets tended to produce more friction when compared to the passive self-ligating brackets but were similar to conventional brackets with stainless steel ligatures.

3.
Dent J (Basel) ; 10(10)2022 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-36286006

RESUMO

Adhesion remains a key element in dentistry, whether approached in prosthetics, odontology, or orthodontics. It is a continuously researched aspect, as improved materials and adhesive methods keep emerging in the market. No orthodontic treatment can be effective without the proper adhesion strength of the bonded elements on the teeth. The objective of this research, in the broad context of self-ligating versus conventional brackets, was to compare active and passive self-ligating systems with a conventional one by conducting an in vitro study on human-extracted premolars. Shear bond strength tests were executed by means of an advanced materials-testing machine that generated maximum load and tensile strength values. The data obtained underwent statistical analysis with a statistical threshold of p < 0.05. The results regarding the statistical significance were acquired when comparing the passive self-ligating system with the active self-ligating and conventional systems (load-at-maximum-load mean 204.9, SD 91.09, and p < 0.05). In this study, the passive self-ligating bracket system appears to present increased shear bond strength.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa