RESUMO
INTRODUCTION: Despite advanced ablation strategies and major technological improvements, treatment of persistent atrial fibrillation (AF) remains challenging and the underlying pathophysiology is not fully understood. This study analyzed the multiple procedure outcome and safety of catheter ablation of spatiotemporal dispersions (DISPERS) detected by artificial intelligence (AI)-guided software in patients with long-standing persistent AF. METHODS AND RESULTS: The Volta VX1 software was used for 50 consecutive patients undergoing catheter ablation for persistent AF. First, high-density mapping (78% biatrial) with a multipolar mapping catheter was performed. In addition to pulmonary vein isolation (PVI), ablation of DISPERS was performed aiming at homogenizing, dissecting, isolating, or connecting DISPERS areas to nonconducting anatomical structures. Follow-up contained regular visits at our outpatient clinic at 1, 3, 6, and 12 months including 7-day Holter electrocardiograms. Patients were mainly suffering from long-standing persistent AF (mean AF duration 50.30 ± 54.28 months). Following PVI, ablation of left atrial and right atrial DISPERS areas led to AF cycle length prolongation (mean of 162.0 ± 16.6 to 202.2 ± 21.6 ms after) and AF termination to atrial tachycardia (AT) or sinus rhythm (SR) in 12 patients (24%). No stroke or pericardial effusion occurred; major groin complications (pseudoaneurysm n = 1, atrioventricular fistula n = 1) were detected in two patients. After a blanking period of 6 weeks, recurrence of any atrial arrhythmia was documented in 26 patients (52%). The majority of patients presented with organized AT (n = 15) while AF was present in n = 9 patients and AT/AF was observed in n = 2 patients. Twenty-two patients underwent reablation. During a mean follow-up of 363.14 ± 187.42 days and after an average of 1.46 ± 0.68 procedures, 82% of patients remained in stable SR. CONCLUSION: DISPERS-guided ablation using machine learning software (the Volta VX1 software) in addition to PVI in long-standing persistent AF ablation resulted in high long-term success rates regarding AF and AT elimination. Most arrhythmia recurrences were reentrant AT. After a total of 1.46 ± 0.68 procedures, freedom from AF/AT was 82%. Despite prolonged procedure times complication rates were low. Randomized studies are necessary to evaluate long-term efficacy of dispersion-guided ablation using AI.
Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Taquicardia Supraventricular , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Inteligência Artificial , Resultado do Tratamento , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , RecidivaRESUMO
INTRODUCTION: Pulmonary vein isolation (PVI) using radiofrequency ablation (RFA) is an established treatment strategy for atrial fibrillation (AF). To improve PVI efficacy and safety, high-power short-duration (HPSD) ablation and pulsed-field ablation (PFA) were recently introduced into clinical practice. This study aimed to determine the extent of myocardial injury and systemic inflammation following PFA, HPSD, and standard RFA using established biomarkers. METHODS: We included 179 patients with paroxysmal AF receiving first-time PVI with different ablation technologies: standard RFA (30-40 W/20-30 s, n = 52), power-controlled HPSD (70 W/5-7 s, n = 60), temperature-controlled HPSD (90 W/4 s, n = 32), and PFA (biphasic, bipolar waveform, n = 35). High-sensitivity cardiac troponin T (hs-cTnT), creatine kinase (CK), CK MB isoform (CK-MB), and white blood cell (WBC) count were determined before and after ablation. RESULTS: Baseline characteristics were well-balanced between groups (age 63.1 ± 10.3 years, 61.5% male). Postablation hs-cTnT release was significantly higher with PFA (1469.3 ± 495.0 ng/L), HPSD-70W (1322.3 ± 510.6 ng/L), and HPSD-90W (1441.2 ± 409.9 ng/L) than with standard RFA (1045.9 ± 369.7 ng/L; p < .001). CK and CK-MB release was increased with PFA by 3.4-fold and 5.8-fold, respectively, as compared to standard RFA (p < .001). PFA was associated with the lowest elevation in WBC (Δ1.5 ± 1.5 × 109 /L), as compared to standard RFA (Δ3.8 ± 2.5 × 109 /L, p < .001), HPSD-70W (Δ2.7 ± 1.7 × 109 /L, p = .037), and HPSD-90W (Δ3.6 ± 2.5 × 109 /L, p < .001). CONCLUSION: Among the four investigated ablation technologies, PFA was associated with the highest myocardial injury and the lowest inflammatory reaction.
Assuntos
Fibrilação Atrial , Ablação por Cateter , Traumatismos Cardíacos , Veias Pulmonares , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Feminino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Creatina Quinase Forma MB , Inflamação/diagnóstico , Veias Pulmonares/cirurgia , Troponina T , Ablação por Cateter/efeitos adversos , Resultado do Tratamento , RecidivaRESUMO
BACKGROUND: Lesion durability and transmurality are crucial for successful radiofrequency (RF) ablation. This study provides a model of real-time RF lesion visualization and insights into the role of underlying parameters, as local impedance (LI). METHODS: A force-sensing, LI-sensing catheter was used for lesion creation in an ex vivo model involving cross-sections of porcine cardiac preparations. During 60 s of RF application, one measurement per second was performed regarding lesion size and available ablation parameters. In total, 1847 measurements from n = 36 lesions were performed. Power (20-50 W) and contact force (1-5 g, 10-15 g, 20-25 g) were systematically alternated. RESULTS: Lesion formation was most prominent in the first seconds of RF application during which nonlinear lesion growth was observed (max. 1.08 mm/s for lesion depth and 2.71 mm/s for lesion diameter). Power levels determined the extent of lesion formation in the early phase. After 20 s, lesion size growth velocity approaches 0.1 mm/s at all power levels. LI changes were also highest in the first seconds (up to - 12 Ω/s) and decreased to less than - 0.1Ω/s after prolonged application. CONCLUSION: Lesion formation in irrigated RF ablation is a nonlinear process. Final lesion size resulting from an RF application is mainly influenced by high rates of lesion growth in the first seconds of ablation. LI seems to be a good surrogate for differentiating changes in lesion formation.
Assuntos
Ablação por Cateter , Suínos , Animais , Ablação por Cateter/métodos , Sistemas Computacionais , Impedância Elétrica , Técnicas In Vitro , Ablação por Radiofrequência/métodos , Cirurgia Assistida por Computador/métodosRESUMO
AIMS: This retrospective study sought to compare complication rates and efficacy of power-controlled very high-power short-duration (vHPSD) and conventional catheter ablation in a large cohort of patients with atrial fibrillation (AF). METHODS AND RESULTS: We analyzed 1115 consecutive patients with AF (38.7% paroxysmal, 61.3% persistent) who received first-time catheter ablation at our centre from 2015 to 2021. Circumferential pulmonary vein isolation ± additional substrate ablation using an irrigated-tip catheter was performed with vHPSD (70 W/5-7 s or 60 W/7-10 s) in 574 patients and with conventional power (30-35 W/15-30 s) in 541 patients. Baseline characteristics were well-balanced between groups (mean age 65.1 ± 11.2 years, 63.4% male). The 30-day incidence of cardiac tamponade [2/574 (0.35%) vs. 1/541 (0.18%), P = 0.598], pericardial effusion ≥ 10 mm [2/574 (0.35%) vs. 1/541 (0.18%), P = 0.598] and transient ischaemic attack [1/574 (0.17%) vs. 2/541 (0.37%), P = 0.529] was not significantly different between vHPSD and conventional ablation. No stroke, atrio-esophageal fistula, cardiac arrest or death occurred. Procedure (122.2 ± 46.8 min vs. 155.0 ± 50.5 min, P < 0.001), radiofrequency (22.4 ± 19.3 min vs. 52.9 ± 22.0 min, P < 0.001), and fluoroscopy (8.1 ± 7.2 vs. 9.2 ± 7.4, P = 0.016) duration were significantly shorter in the vHPSD group. At 12 months follow-up, freedom of any atrial arrhythmia was 44.1% vs. 34.2% (P = 0.010) in persistent AF and 78.1% vs. 70.2% in paroxysmal AF (P = 0.068). CONCLUSION: vHPSD ablation is as safe as conventional ablation and is associated with an improved long-term efficacy in persistent AF.
Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Feminino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Catéteres , Veias Pulmonares/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodosRESUMO
AIMS: Battery electric vehicle (BEV) sales and use are rapidly expanding. Battery electric vehicles, along with their charging stations, are a potential source of electromagnetic interference (EMI) for patients with cardiac implantable electronic devices (CIEDs). The new 'high-power' charging stations have the potential to create strong electromagnetic fields and induce EMI in CIEDs, and their safety has not been evaluated. METHODS AND RESULTS: A total of 130 CIED patients performed 561 charges of four BEVs and a test vehicle (350â kW charge capacity) using high-power charging stations under continuous 6-lead electrocardiogram monitoring. The charging cable was placed directly over the CIED, and devices were programmed to maximize the chance of EMI detection. Cardiac implantable electronic devices were re-interrogated after patients charged all BEVs and the test vehicle for evidence of EMI. There were no incidences of EMI, specifically no over-sensing, pacing inhibition, inappropriate tachycardia detection, mode switching, or spontaneous reprogramming. The risk of EMI on a patient-based analysis is 0/130 [95% confidence interval (CI) 0%-2%], and the risk of EMI on a charge-based analysis is 0/561 (95% CI 0%-0.6%). The effective magnetic field along the charging cable was 38.65â µT and at the charging station was 77.9â µT. CONCLUSIONS: The use of electric cars with high-power chargers by patients with cardiac devices appears to be safe with no evidence of clinically relevant EMI. Reasonable caution, by minimizing the time spent in close proximity with the charging cables, is still advised as the occurrence of very rare events cannot be excluded from our results.
Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Humanos , Campos Eletromagnéticos/efeitos adversos , Fontes de Energia Elétrica , CoraçãoRESUMO
BACKGROUND: The influence of power, duration and contact force (CF) on radiofrequency (RF) lesion formation is well known, whereas data on local impedance (LI) and electrode-tissue-coverage (ETC) is scarce. The objective was to investigate their effect on lesion formation in an ex vivo model. METHODS AND RESULTS: An ex vivo model was developed utilizing cross-sections of porcine heart preparations and a force-sensing, LI-measuring catheter. N = 72 lesion were created systematically varying ETC (minor/full), CF (1-5 g, 10-15 g, 20-25 g) and power (20 W, 30 W, 40 W, 50 W). In minor ETC, the distal tip of the catheter was in electric contact with the tissue, in full ETC the whole catheter tip was embedded within the tissue. Lesion size and all parameters were measured once per second (n = 3320). LI correlated strongly with lesion depth (r = -0.742 for ΔLI; r = 0.781 for %LI-drop). Lesions in full ETC were significantly wider and deeper compared to minor ETC (p < .001) and steam pops were more likely. Baseline LI, ΔLI, and %LI-drop were significantly higher in full ETC (p < .001). In lesions resulting in steam pops, baseline LI, and ΔLI were significantly higher. The influence of CF on lesion size was higher in minor ETC than in full ETC. CONCLUSIONS: ETC is a main determinant of lesion size and occurrence of steam pops. Baseline LI and LI-drop are useful surrogate parameters for real-time assessment of ETC and ΔLI correlates strongly with lesion size.
Assuntos
Ablação por Cateter , Vapor , Suínos , Animais , Impedância Elétrica , Ablação por Cateter/métodos , EletrodosRESUMO
AIMS: Bipolar radiofrequency ablation (B-RFA) has been reported as a bail-out strategy for the treatment of therapy refractory ventricular arrhythmias (VA). Currently, existing setups have not been standardized for B-RFA, while the impact of conventional B-RFA approaches on lesion formation remains unclear. METHODS AND RESULTS: (i) In a multicentre observational study, patients undergoing B-RFA for previously therapy-refractory VA using a dedicated B-RFA setup were retrospectively analysed. (ii) Additionally, in an ex vivo model lesion formation during B-RFA was evaluated using porcine hearts. In a total of 26 procedures (24 patients), acute success was achieved in all 14 ventricular tachycardia (VT) procedures and 7/12 procedures with premature ventricular contractions (PVC), with major complications occurring in 1 procedure (atrioventricular block). During a median follow-up of 211 days in 21 patients, 6/11 patients (VT) and 5/10 patients (PVC) remained arrhythmia-free. Lesion formation in the ex vivo model during energy titration from 30 to 50 W led to similar lesion volumes compared with initial high-power 50 W B-RFA. Lesion size significantly increased when combining sequential unipolar and B-RFA (1429 mm3 vs. titration 501 mm3 vs. B-RFA 50 W 423 mm3, P < 0.001), an approach used in overall 58% of procedures and more frequently applied in procedures without VA recurrence (92% vs. 36%, P = 0.009). Adipose tissue severely limited lesion formation during B-RFA. CONCLUSION: Using a dedicated device for B-RFA for therapy-refractory VA appears feasible and safe. While some patients need repeat ablation, success rates were encouraging. Sequential unipolar and B-RFA may be favourable for lesion formation.
Assuntos
Ablação por Cateter , Taquicardia Ventricular , Complexos Ventriculares Prematuros , Animais , Ablação por Cateter/métodos , Estudos Retrospectivos , Suínos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Resultado do Tratamento , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/cirurgiaRESUMO
BACKGROUND: In patients with persistent left superior vena cava (PLSVC) ablation procedures can be challenging. We sought to determine the feasibility and safety of left atrial ablations in patients with PLSVC, especially when PLSVC is unknown prior to the ablation procedure. METHODS AND RESULTS: In this retrospective analysis 15 adult patients (mean age 64.6 ± 14.5 years, 53.3% male) with PLSVC undergoing 27 ablation procedures for atrial fibrillation or left atrial flutter were included. In 5 (33.3%) patients PLSVC was only discovered during the procedure. Transseptal puncture (TSP) was declared "difficult" by the ablating physician in 13 of 27 (48.2%) procedures and was not successfully completed in the first attempt in two patients with known PLSVC. Once TSP was successfully completed, all relevant structures were reached both during mapping and ablation in all procedures independent of whether PLSVC was known prior to the procedure. One major complication (3.7%) occurred in 27 procedures in a patient with known PLSVC. In the patients with unknown PLSVC no complication occurred. CONCLUSION: In experienced hands, left atrial access and ablation in patients with PLSVC is feasible and safe, particularly with regard to patients in whom the PLSVC is unknown prior to the ablation procedure.
Assuntos
Fibrilação Atrial , Ablação por Cateter , Veia Cava Superior Esquerda Persistente , Adulto , Idoso , Ablação por Cateter/métodos , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Veia Cava Superior/cirurgiaRESUMO
Freshly harvested Boletus edulis mushrooms are subjected to rapid loss of quality due to the high moisture content and enzymatic activity. Drying time, quality characteristics, microstructural and thermal properties were studied in mushrooms ground to puree subjected to hot air drying (HAD), freeze drying (FD) and centrifugal vacuum drying (CVD). The influence of hot water blanching and UV-C pretreatments was additionally investigated. The rehydration ability of mushroom powders was improved by FD, especially without pretreatment or combined to UV-C exposure. The HAD and CVD, with no pretreatment or combined to UV-C, ensured good preservation of phenolics and antioxidant activity of dried mushrooms. The total difference in color of mushroom pigments extracted in acetone was lower in samples dried by CVD and higher in ones by FD. Blanching before HAD produced whiter product probably due to the reduced polyphenoloxidase activity. Scanning Electron Microscopy (SEM) analysis showed fewer physical changes in FD-samples. Heat-induced structural changes were noticed by Differential Scanning Calorimetry (DSC), Thermogravimetry (TG) and Derivative Thermogravimetry (DTG) analysis, in particular of biopolymers, confirmed by ATR-FTIR analysis. Based on our complex approach, the UV pretreatment of mushrooms could be a better alternative to water blanching. Centrifugal vacuum emerged as a new efficient drying method in terms of bioactive compounds, color and thermal stability, while FD led to better rehydration ability and microstructure.
Assuntos
Agaricales , Doenças Cardiovasculares , Antioxidantes/química , Basidiomycota , Dessecação/métodos , Liofilização , Vácuo , Água/químicaRESUMO
BACKGROUND: Steam pops are a rare complication associated with radiofrequency (RF) ablation and are hard to predict. The aim of this study was to assess the influence of coverage between the RF ablation electrode and cardiac tissue on steam pop incidence and lesion size. METHODS AND RESULTS: An ex vivo model using porcine cardiac preparations and contact force sensing catheters was designed to perform RF ablations at different coverage levels between the RF electrode and cardiac tissue. During coverage level I, only the distal part of the ablation electrode was in contact with tissue. During coverage level II half of the ablation electrode, and during coverage level III the entire ablation electrode was embedded in tissue. RF applications (n = 60) at different coverage levels I-III were systematically performed using the same standardized ablation protocol. Ablations during coverage level III resulted in a significantly higher rate of steam pops (100%) when compared to ablations during coverage level II (10%) and coverage level I (0%), log rank p < .001. Coverage level I ablations resulted in significantly smaller lesion depths, diameters, and impedance drops when compared to higher coverage level ablations, p < .001. In the controlled ex vivo model, there was no difference in applied contact force or energy between different coverage levels. CONCLUSIONS: The level of coverage between RF electrode, cardiac tissue, and the surrounding fluid significantly influenced the incidence of steam pops in an ex vivo setup. Larger coverage between RF electrode and tissue resulted in significantly larger lesion dimensions.
Assuntos
Ablação por Cateter , Ablação por Radiofrequência , Animais , Ablação por Cateter/efeitos adversos , Eletrodos , Desenho de Equipamento , Incidência , Vapor , SuínosRESUMO
Monocyte extravasation into the vessel wall is a key step in atherogenesis. It is still elusive how monocytes transmigrate through the endothelial cell (EC) monolayer at atherosclerosis predilection sites. Platelets tethered to ultra-large von Willebrand factor (ULVWF) multimers deposited on the luminal EC surface following CD40 ligand (CD154) stimulation may facilitate monocyte diapedesis. Human ECs grown in a parallel plate flow chamber for live-cell imaging or Transwell permeable supports for transmigration assay were exposed to fluid or orbital shear stress and CD154. Human isolated platelets and/or monocytes were superfused over or added on top of the EC monolayer. Plasma levels and activity of the ULVWF multimer-cleaving protease ADAMTS13 were compared between coronary artery disease (CAD) patients and controls and were verified by the bioassay. Two-photon intravital microscopy was performed to monitor CD154-dependent leukocyte recruitment in the cremaster microcirculation of ADAMTS13-deficient versus wild-type mice. CD154-induced ULVWF multimer-platelet string formation on the EC surface trapped monocytes and facilitated transmigration through the EC monolayer despite high shear stress. Two-photon intravital microscopy revealed CD154-induced ULVWF multimer-platelet string formation preferentially in venules, due to strong EC expression of CD40, causing prominent downstream leukocyte extravasation. Plasma ADAMTS13 abundance and activity were significantly reduced in CAD patients and strongly facilitated both ULVWF multimer-platelet string formation and monocyte trapping in vitro. Moderate ADAMTS13 deficiency in CAD patients augments CD154-mediated deposition of platelet-decorated ULVWF multimers on the luminal EC surface, reinforcing the trapping of circulating monocytes at atherosclerosis predilection sites and promoting their diapedesis.
Assuntos
Proteína ADAMTS13/metabolismo , Plaquetas/metabolismo , Antígenos CD40/metabolismo , Comunicação Celular/fisiologia , Células Endoteliais/metabolismo , Fator de von Willebrand/metabolismo , Adolescente , Adulto , Idoso , Animais , Aterosclerose/metabolismo , Células Cultivadas , Endotélio Vascular/metabolismo , Células Endoteliais da Veia Umbilical Humana , Humanos , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Knockout , Pessoa de Meia-Idade , Monócitos/metabolismo , Agregação Plaquetária/fisiologia , Estresse Mecânico , Adulto JovemRESUMO
AIMS: Pulmonary vein isolation (PVI) using radiofrequency ablation (RFA) in patients with paroxysmal atrial fibrillation (PAF) is effective but hampered by pulmonary vein reconnection due to insufficient ablation lesions. High-power delivery over a short period of time (HPSD) in RFA is stated to create more efficient lesions. The aim of this study was to compare intraprocedural safety and outcome of HPSD ablation to conventional power settings in patients undergoing PVI for PAF. METHODS AND RESULTS: We included 197 patients with PAF that were scheduled for PVI. An ablation protocol with 70 W and a duration cut-off of 7 s at the anterior left atrium (LA) and 5 s at the posterior LA (HPSD group; n = 97) was compared to a conventional power protocol with 30-40 W for 20-40 s (standard group; n = 100) in terms of periprocedural complications and a 1-year outcome. The HPSD group showed significantly less arrhythmia recurrence during 1-year follow-up with 83.1% of patients free from atrial fibrillation compared to 65.1% in the standard group (P < 0.013). No pericardial tamponade, periprocedural thromboembolic complications, or atrio-oesophageal fistula occurred in either group. Mean radiofrequency time (12.4 ± 3.4 min vs. 35.6 ± 12.1 min) and procedural time (89.5 ± 23.9 min vs. 111.15 ± 27.9 min) were significantly shorter in the HPSD group compared to the standard group (both P < 0.001). CONCLUSION: High-power short-duration ablation demonstrated a comparable safety profile to conventional ablation. High-power short-duration ablation using 70 W for 5-7 s leads to significantly less arrhythmia recurrences after 1 year. Radiofrequency and procedural time were significantly shortened.
Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Átrios do Coração , Humanos , Veias Pulmonares/cirurgia , Recidiva , Resultado do TratamentoRESUMO
AIMS: The aim of this retrospective cohort study was to assess the influence of early recurrence (ER) after pulmonary vein isolation (PVI) for paroxysmal atrial fibrillation (AF) on long-term outcomes and to identify clinical variables associated with ER. METHODS: We retrospectively collected clinical and procedural data from 1285 patients with paroxysmal AF who underwent PVI from 2011 to 2016. Kaplan-Meier, receiver operating characteristic (ROC) curve, logistic and Cox regression analyses were performed to analyze the influence of ER on long-term outcomes. RESULTS: ER was observed in 13% of patients. Kaplan-Meier analyses showed significantly different outcomes in 1285 patients with and without ER (49% vs 74%, log rank P < .01) and in 286 patients in the subgroup that underwent reablation (44% vs 79%, log rank P < .01). The hazard ratio (HR) of ER was 1.7 within 48 hours (5% of patients), 2.7 within 1 month (5%), 3.0 within 2 months (2%), and 6.4 within 3 months (1%) for late recurrence (LR), P < .01. ROC analysis (area under the curve [AUC] = 0.79) resulted in 70.3% sensitivity and 74.2% specificity for a 14-day blanking period, and 53.1% sensitivity and 85.5% specificity for a 30-day blanking period. Female patients (odds ratio [OR] 1.69, P < .01) and those with diabetes (OR 1.95, P = .01) were at higher risk for ER. CONCLUSIONS: ER is observed in a substantial number of patients with paroxysmal AF after PVI and has a continuous direct effect on LR according to the timing of ER. Randomized trials are required to assess the safety and effects of reablations in a shortened blanking period on long-term outcomes.
Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Estudos Retrospectivos , Fatores de Risco , Sensibilidade e EspecificidadeRESUMO
Introduction: Renal dysfunction is a recognized complication of obesity with an incompletely characterized pathophysiology. Improvement of glomerular filtration rate (GFR) after metabolic and bariatric surgery (MBS) has been reported across all classes of renal function. Inter-gender differences with regard to correlates of renal function have been described, but the influence of body composition is an understudied area. We aimed to explore determinants of renal function in obesity and to assess its variations after MBS, with a focus on body composition parameters in males and females, respectively. Materials methods: We conducted a retrospective study on 196 patients who underwent laparoscopic sleeve gastrectomy, evaluated preoperatively and 6 months after the intervention. Recorded data included clinical and biochemical assessment, as well as body composition estimation via dual-energy X-ray absorptiometry. Serum creatinine-based formulas were used for the estimation of GFR. Results: We included a total of 196 patients (80 males and 116 females), with a mean age of 41.43 ± 10.79. Median baseline body mass index was 42.6 (6.61) kg/m2 and 6 months excess weight loss (EWL) reached 71.43 ± 17.18%, in females, estimated GFR correlated negatively with visceral adipose tissue (VAT) mass (rho=-.368) and this correlation was stronger in females with type 2 diabetes mellitus. Moreover, women in the third VAT mass tertile were 5 times more likely to have reduced GFR compared to the first tertile. Renal function improved after MBS across all classes of filtration. In males, this improvement correlated with EWL (rho=.358) and lean mass variation (rho=-.412), while in females it correlated with VAT mass variation (rho=-.266). Conclusions: Our results are consistent with previous findings on the positive impact of MBS on renal function and suggest a more prominent impact of visceral adiposity on GFR in females.
Assuntos
Cirurgia Bariátrica , Taxa de Filtração Glomerular , Gordura Intra-Abdominal , Obesidade , Humanos , Feminino , Masculino , Adulto , Estudos Retrospectivos , Pessoa de Meia-Idade , Obesidade/complicações , Obesidade/cirurgia , Obesidade/fisiopatologia , Adiposidade , Fatores Sexuais , Composição Corporal , Índice de Massa Corporal , Obesidade Mórbida/cirurgia , Obesidade Mórbida/complicações , Obesidade Mórbida/fisiopatologia , Redução de Peso/fisiologia , Nefropatias/etiologia , Nefropatias/fisiopatologiaRESUMO
The question of optimal timing for catheter ablation of atrial fibrillation (AF) to achieve best outcomes remains a crucial clinical issue. As AF occurs less frequently in younger patients, data regarding Diagnosis-to-Ablation Time (DAT) is especially limited in patients under the age of 55 years with persistent AF. We therefore analyzed the temporal relationship between initial AF presentation and timing of catheter ablation in this cohort. We conducted a retrospective single-centre study of patients ≤ 55 years with persistent AF who underwent first-time catheter ablation at our center. The cohort was divided into patients that underwent catheter ablation after diagnosis of persistent AF within a DAT of ≤ 12 months and patients with a DAT of > 12 months. A total of 101 patients (median age 51 years; female n = 19 (18.8%)) with persistent AF were included. Ablation was performed within 12 months ("early DAT") in 51 patients and > 12 months ("late DAT") in 50 patients. Pulmonary vein isolation was performed using high-power short-duration (HPSD) radiofrequency ablation. Median DAT was 5 months (1-12 months) in the early ablation group and 36 months (13-240 months) in the late ablation group. The median follow-up was 11.3 months (0.03-37.1 months). The rate of any atrial arrhythmia recurrence after a 30-day blanking period was significantly lower in the early DAT group (13/51 patients; 25.5%) as compared to the late DAT group (26/50 patients; 52.0%) (log rank test; p = 0.003). Catheter ablation performed > 12 months after the initial AF diagnosis was an independent predictor for the occurrence of any atrial arrythmia (OR: 2.58; (95%-CI: 1.32-5.07). Early first-time catheter ablation (DAT ≤ 12 months) in patients ≤ 55 years with persistent AF is associated with a significantly lower rate of arrhythmia recurrence.
Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/cirurgia , Feminino , Masculino , Pessoa de Meia-Idade , Ablação por Cateter/métodos , Estudos Retrospectivos , Resultado do Tratamento , Adulto , Recidiva , Fatores de Tempo , Veias Pulmonares/cirurgiaRESUMO
BACKGROUND: Pulsed field ablation (PFA) has become increasingly important in the treatment of cardiac arrhythmias. In addition to single-shot devices mainly used for pulmonary vein isolation, focal PFA may provide a treatment option that increases the versatility of the technique. OBJECTIVE: The purpose of this study was to provide data on feasibility, safety, and long-term outcome of focal PFA for ablation of complex atrial tachycardia (AT). METHODS: All consecutive patients (n = 34) with complex AT treated at our department between 2022 and 2023 with a focal PFA system (CENTAURI™, Galvanize Therapeutics) were included. The majority of patients (32/34) previously had undergone at least 1 radiofrequency ablation. Established contact force-sensing catheters were used for PFA application in combination with a PFA generator. Pulsed electric field trains were conducted in a R-wave triggered manner. RESULTS: Acute procedural success was accomplished in all patients. PFA included creation of 51 linear lesions and (re)isolation of 12 pulmonary veins. Mean procedural duration was 102.7 ± 30.3 minutes, with left atrial dwell time of 75.0 ± 24.7 minutes. Mean fluoroscopy duration was 8.7 ± 5.3 minutes. No complications occurred. After mean follow-up of 340.9 ± 130.1 days, recurrence of any AT occurred in 15 patients (44.1%). During 9 reablations, 3 gaps in previously created linear lesions were detected; the majority of recurrences (n = 6) were not related to previous PFA lesion creation. CONCLUSION: Focal PFA of complex AT substrates was safe and efficient. Acute procedural success was 100%. After 1 year, the majority of patients were in sinus rhythm. A minority of recurrences was caused by insufficient PFA lesion creation.
RESUMO
BACKGROUND: Data regarding uninterrupted oral anticoagulation in patients with chronic kidney disease (CKD) during catheter ablation for left atrial arrhythmias is limited. This study aimed to evaluate the safety and efficacy of periprocedural uninterrupted direct oral anticoagulants (DOAC) compared with uninterrupted phenprocoumon in patients with CKD undergoing left atrial catheter ablation. METHODS AND RESULTS: We conducted a retrospective single-center study of patients who underwent left atrial catheter ablation between 2016 and 2019 with underlying chronic kidney disease (glomerular filtration rate (GFR) between 15 and 45 ml/min). The primary objective of this study was to investigate whether direct oral anticoagulant (DOAC) therapy or warfarin presents a superior safety profile in patients with chronic kidney disease (CKD) undergoing left atrial catheter ablation. We compared periprocedural complications (arteriovenous fistula, aneurysm, significant hematoma (> 5 cm)) and/or bleeding (drop in hemoglobin of >2 g/dl, pericardial effusion, retroperitoneal bleeding, other bleeding, stroke) between patients receiving either uninterrupted DOAC or warfarin therapy. Secondary analysis included patient baseline characteristics as well as procedural data. A total of 188 patients (female n = 108 (57%), mean age 75.3 ± 8.1 years, mean GFR 36.8 ± 6 ml/min) were included in this study. Underlying arrhythmias were atrial fibrillation (n = 104, 55.3%) and atypical atrial flutter (n = 84, 44.7%). Of these, n = 132 patients (70%) were under a DOAC medication, and n = 56 (30%) were under phenprocoumon. Major groin complications including pseudoaneurysm and/or AV fistula occurred in 8.9% of patients in the phenprocoumon group vs. 11.3% of patients in the DOAC group, which was not statistically significant (p = 0.62). Incidence of cardiac tamponade (2.3% vs. 0%; p = 0.55) and stroke (0% vs. 0%) were low in both DOAC and phenprocoumon groups with similar post-procedural drops in hemoglobin levels (1.1±1 g/dl vs 1.1±0.9 g/dl; p = 0.71). CONCLUSION: The type of anticoagulation had no significant influence on bleeding or thromboembolic events as well as groin complications in this retrospective study. Despite observing an increased rate of groin complications, the uninterrupted use of DOAC or phenprocoumon during left atrial catheter ablation in patients with CKD appears to be feasible and effective.
RESUMO
Currently, pulmonary vein isolation (PVI) is the gold standard in catheter ablation for atrial fibrillation (AF). However, PVI alone may be insufficient in the management of persistent AF, and complementary methods are being explored. One such method takes an anatomical approach-improving both its success rate and lesion durability may lead to improved treatment outcomes. An additional approach complementary to the anatomical one is also attracting attention, one that focuses on epicardial conduction. This involves ethanol ablation of the vein of Marshall (VOM) and can be very effective in blocking epicardial conduction related to Marshall structure; it is becoming incorporated into standard treatment. However, the pitfall of this "Marshall-PLAN", a method that combines an anatomical approach with ethanol infusion within the VOM (Et-VOM), is that Et-VOM and other line creations are not always successfully completed. This has led to cases of AF and/or atrial tachycardia (AT) recurrence even after completing this lesion set. Investigating effective adjunctive methods will enable us to complete the lesion set with the aim to lower the rates of recurrence of AF and/or AT in the future.
RESUMO
BACKGROUND: Pulsed field ablation (PFA) is increasingly used in clinical practice for the treatment of atrial fibrillation. While the susceptibility of erythrocytes to electroporation is well established, the effect of cardiac PFA technologies on hemolysis has remained underreported. The aim of this study was to investigate the incidence, severity, and clinical impact of PFA-induced hemolysis. METHODS: We included n=145 patients undergoing atrial fibrillation catheter ablation with a pentaspline PFA catheter (biphasic, bipolar pulses of 2 kV) and n=70 patients receiving radiofrequency ablation (40-90 W) at 4 high-volume European centers. The lesion set comprised pulmonary vein isolation for paroxysmal atrial fibrillation and pulmonary vein isolation±additional lesions for persistent atrial fibrillation. Hemolysis and renal function biomarkers were analyzed in blood samples at baseline, at the end of ablation, and 24 hours after the procedure. RESULTS: Baseline characteristics were well balanced between groups (overall mean 65.7±9.4 years; 69.3% men). The ablation procedures comprised a mean of 61.6±27.4 PFA deliveries and 26.3±15.0 minutes RF duration. Hemolysis was detected in 94.3% versus 6.8% of patients after PFA versus radiofrequency ablation (P<0.001): PFA was associated with significantly lower haptoglobin levels (0.5±0.4 versus 1.0±0.4 g/L), while free plasma hemoglobin (592.8±330.6 versus 147.8±183.0 mg/L), bilirubin (21.3±11.3 versus 14.8±8.8 µmol/L), and LDH (lactate dehydrogenase, 352.7±115.7 versus 253.2±56.5 U/L) were significantly higher after PFA compared with radiofrequency ablation (all P<0.001). Hemolysis correlated with the number of PFA deliveries (r=0.62 [95% CI, 0.33-0.80]; P<0.001), with the highest severity occurring ≥54 PFA deliveries. After PFA, hemoglobinuria occurred in 36.4%, while creatinine increase was higher in patients with baseline glomerular filtration rate <50 mL/min than with baseline glomerular filtration rate >50 mL/min (Δcrea, 27.0±103.1 versus -0.2±12.1 µmol/L; P=0.010). CONCLUSIONS: Intravascular hemolysis is a frequent finding after PFA and increases with the number of PFA deliveries. Until the clinical impact of PFA-associated hemolysis is fully elucidated, a careful titration of PFA deliveries during the ablation procedure is warranted.