1.
J Physiol ; 599(22): 5121-5132, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34647325

RESUMO

Ventilation is inhomogeneous in the lungs across species. It has been hypothesized that ventilation inhomogeneity is largely determined by the design of the airway branching network. Because exchange of gases at the alveolar barrier is more efficient when gas concentrations are evenly distributed at subacinar length scales, it is assumed that a 'functional unit' of ventilation exists within the lung periphery, where gas concentration becomes uniform. On the other hand, because the morphology of pulmonary airways and alveoli, and the distribution of inhaled fluorescent particles show self-similar fractal properties over a wide range of length scales, it has been predicted that fractal dimension of ventilation approaches unity within an internally homogeneous functional unit of ventilation. However, the existence of such a functional unit has never been demonstrated experimentally due to lack of in situ gas concentration measurements of sufficient spatial resolution in the periphery of a complex bifurcating network. Here, using energy-subtractive synchrotron radiation tomography, we measured the distribution of an inert gas (Xe) in the in vivo rabbit lung during Xe wash-in breathing manoeuvres. The effects of convective flow rate, diffusion and cardiac motion were also assessed. Fractal analysis of resulting gas concentration and tissue density maps revealed that fractal dimension was always smaller for Xe than for tissue density, and that only for the gas, a length scale existed where fractal dimension approached unity. The length scale where this occurred was seen to correspond to that of a rabbit acinus, the terminal structure comprising only alveolated airways. KEY POINTS: Gas ventilation is inhomogeneous in the lung of many species. However, it is not known down to what length scales this inhomogeneity persists. It is generally assumed that ventilation becomes homogeneous at subacinar length scales, beyond the spatial resolution of commonly available imaging techniques, hence this has not been demonstrated experimentally. Here we measured the distribution of inhaled Xe gas in the rabbit lung using synchrotron radiation energy-subtractive imaging and used fractal analysis to show that ventilation becomes internally uniform within regions about the size of rabbit lung acini.


Assuntos
Fractais , Pulmão , Animais , Difusão , Pulmão/diagnóstico por imagem , Alvéolos Pulmonares , Coelhos , Respiração
2.
Crit Care Med ; 47(9): e774-e781, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31162202

RESUMO

OBJECTIVES: Airway closure is involved in adverse effects of mechanical ventilation under both general anesthesia and in acute respiratory distress syndrome patients. However, direct evidence and characterization of individual airway closure is lacking. Here, we studied the same individual peripheral airways in intact lungs of anesthetized and mechanically ventilated rabbits, at baseline and following lung injury, using high-resolution synchrotron phase-contrast CT. DESIGN: Laboratory animal investigation. SETTING: European synchrotron radiation facility. SUBJECTS: Six New-Zealand White rabbits. INTERVENTIONS: The animals were anesthetized, paralyzed, and mechanically ventilated in pressure-controlled mode (tidal volume, 6 mL/kg; respiratory rate, 40; FIO2, 0.6; inspiratory:expiratory, 1:2; and positive end-expiratory pressure, 3 cm H2O) at baseline. Imaging was performed with a 47.5 × 47.5 × 47.5 µm voxel size, at positive end-expiratory pressure 12, 9, 6, 3, and 0 cm H2O. The imaging sequence was repeated after lung injury induced by whole-lung lavage and injurious ventilation in four rabbits. Cross-sections of the same individual airways were measured. MEASUREMENTS AND MAIN RESULTS: The airways were measured at baseline (n = 48; radius, 1.7 to 0.21 mm) and after injury (n = 32). Closure was observed at 0 cm H2O in three of 48 airways (6.3%; radius, 0.35 ± 0.08 mm at positive end-expiratory pressure 12) at baseline and five of 32 (15.6%; radius, 0.28 ± 0.09 mm) airways after injury. Cross-section was significantly reduced at 3 and 0 cm H2O, after injury, with a significant relation between the relative change in cross-section and airway radius at 12 cm H2O in injured, but not in normal lung (R = 0.60; p < 0.001). CONCLUSIONS: Airway collapsibility increases in the injured lung with a significant dependence on airway caliber. We identify "compliant collapse" as the main mechanism of airway closure in initially patent airways, which can occur at more than one site in individual airways.


Assuntos
Obstrução das Vias Respiratórias/diagnóstico por imagem , Pulmão/diagnóstico por imagem , Pulmão/fisiopatologia , Respiração Artificial/efeitos adversos , Animais , Coelhos , Tomografia Computadorizada por Raios X
3.
Am J Respir Cell Mol Biol ; 57(4): 459-467, 2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-28535074

RESUMO

Despite the importance of dynamic changes in the regional distributions of gas and blood during the breathing cycle for lung function in the mechanically ventilated patient, no quantitative data on such cyclic changes are currently available. We used a novel gated synchrotron computed tomography imaging to quantitatively image regional lung gas volume (Vg), tissue density, and blood volume (Vb) in six anesthetized, paralyzed, and mechanically ventilated rabbits with normal lungs. Images were repeatedly collected during ventilation and steady-state inhalation of 50% xenon, or iodine infusion. Data were acquired in a dependent and nondependent image level, at zero end-expiratory pressure (ZEEP) and 9 cm H2O (positive end-expiratory pressure), and a tidal volume (Vt) of 6 ml/kg (Vt1) or 9 ml/kg (Vt2) at an Inspiratory:Expiratory ratio of 0.5 or 1.7 by applying an end-inspiratory pause. A video showing dynamic decreases in Vb during inspiration is presented. Vb decreased with positive end-expiratory pressure (P = 0.006; P = 0.036 versus Vt1-ZEEP and Vt2-ZEEP, respectively), and showed larger oscillations at the dependent image level, whereas a 45% increase in Vt did not have a significant effect. End-inspiratory Vb minima were reduced by an end-inspiratory pause (P = 0.042, P = 0.006 at nondependent and dependent levels, respectively). Normalized regional Vg:Vb ratio increased upon inspiration. Our data demonstrate, for the first time, within-tidal cyclic variations in regional pulmonary Vb. The quantitative matching of regional Vg and Vb improved upon inspiration under ZEEP. Further study is underway to determine whether these phenomena affect intratidal gas exchange.


Assuntos
Volume Sanguíneo , Interpretação de Imagem Assistida por Computador , Inalação , Pulmão , Respiração Artificial , Síncrotrons , Ventiladores Mecânicos , Animais , Feminino , Pulmão/irrigação sanguínea , Pulmão/diagnóstico por imagem , Pulmão/fisiopatologia , Masculino , Coelhos
4.
Crit Care Med ; 45(4): 687-694, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28107207

RESUMO

OBJECTIVES: Positive pressure ventilation exposes the lung to mechanical stresses that can exacerbate injury. The exact mechanism of this pathologic process remains elusive. The goal of this study was to describe recruitment/derecruitment at acinar length scales over short-time frames and test the hypothesis that mechanical interdependence between neighboring lung units determines the spatial and temporal distributions of recruitment/derecruitment, using a computational model. DESIGN: Experimental animal study. SETTING: International synchrotron radiation laboratory. SUBJECTS: Four anesthetized rabbits, ventilated in pressure controlled mode. INTERVENTIONS: The lung was consecutively imaged at ~ 1.5-minute intervals using phase-contrast synchrotron imaging, at positive end-expiratory pressures of 12, 9, 6, 3, and 0 cm H2O before and after lavage and mechanical ventilation induced injury. The extent and spatial distribution of recruitment/derecruitment was analyzed by subtracting subsequent images. In a realistic lung structure, we implemented a mechanistic model in which each unit has individual pressures and speeds of opening and closing. Derecruited and recruited lung fractions (Fderecruited, Frecruited) were computed based on the comparison of the aerated volumes at successive time points. MEASUREMENTS AND MAIN RESULTS: Alternative recruitment/derecruitment occurred in neighboring alveoli over short-time scales in all tested positive end-expiratory pressure levels and despite stable pressure controlled mode. The computational model reproduced this behavior only when parenchymal interdependence between neighboring acini was accounted for. Simulations closely mimicked the experimental magnitude of Fderecruited and Frecruited when mechanical interdependence was included, while its exclusion gave Frecruited values of zero at positive end-expiratory pressure greater than or equal to 3 cm H2O. CONCLUSIONS: These findings give further insight into the microscopic behavior of the injured lung and provide a means of testing protective-ventilation strategies to prevent recruitment/derecruitment and subsequent lung damage.


Assuntos
Lesão Pulmonar Aguda/etiologia , Lesão Pulmonar Aguda/fisiopatologia , Respiração com Pressão Positiva/efeitos adversos , Alvéolos Pulmonares/fisiopatologia , Lesão Pulmonar Aguda/diagnóstico por imagem , Animais , Simulação por Computador , Masculino , Pressão , Alvéolos Pulmonares/diagnóstico por imagem , Coelhos , Síncrotrons
6.
Eur J Anaesthesiol ; 33(10): 767-75, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27533710

RESUMO

BACKGROUND: It is not well understood how different ventilation modes affect the regional distribution of ventilation, particularly within the injured lung. OBJECTIVES: We compared respiratory mechanics, lung aeration and regional specific ventilation ((Equation is included in full-text article.)) distributions in healthy and surfactant-depleted rabbits ventilated with pressure-regulated volume control (PRVC) mode with a decelerating inspiratory flow or with volume control (VC) mode. DESIGN: Randomised experimental study. ANIMALS AND INTERVENTIONS: New Zealand white rabbits (n = 8) were anaesthetised, paralysed and mechanically ventilated either with VC or PRVC mode (tidal volume: 7 ml kg; rate: 40 min; positive end-expiratory pressure (PEEP): 3 cmH2O), at baseline and after lung injury induced by lung lavage. MAIN OUTCOME MEASURES: Airway resistance (Raw), respiratory tissue damping (G) and elastance (H) were measured by low-frequency forced oscillations. Synchrotron radiation computed tomography during stable xenon wash-in was used to measure regional lung aeration and specific ventilation and the relative fraction of nonaerated, trapped, normally, poorly and hyperinflated lung regions. RESULTS: Lung lavage significantly elevated peak inspiratory pressure (PIP) (P < 0.001). PIP was lower on PRVC compared with VC mode (-12.7 ±â€Š1.7%, P < 0.001). No significant differences in respiratory mechanics, regional ventilation distribution, strain or blood oxygenation could be detected between the two ventilation modes. CONCLUSION: A decelerating flow pattern (PRVC) resulted in equivalent regional ventilation distribution, respiratory mechanics and gas exchange, in both normal and mechanically heterogeneous lungs with, however, a significantly lower peak pressure. Our data suggest that the lower PIP on PRVC ventilation was because of the decelerating flow pattern rather than the ventilation distribution.


Assuntos
Lesão Pulmonar Aguda/fisiopatologia , Lesão Pulmonar Aguda/terapia , Pulmão/fisiologia , Respiração Artificial/métodos , Mecânica Respiratória/fisiologia , Volume de Ventilação Pulmonar/fisiologia , Animais , Masculino , Respiração com Pressão Positiva/métodos , Pressão , Coelhos , Distribuição Aleatória
7.
Anesthesiology ; 119(1): 89-100, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23559029

RESUMO

BACKGROUND: Ventilator-induced lung injury occurs due to exaggerated local stresses, repeated collapse, and opening of terminal air spaces in poorly aerated dependent lung, and increased stretch in nondependent lung. The aim of this study was to quantify the functional behavior of peripheral lung units in whole-lung lavage-induced surfactant depletion, and to assess the effect of positive end-expiratory pressure. METHODS: The authors used synchrotron imaging to measure lung aeration and regional specific ventilation at positive end-expiratory pressure of 3 and 9 cm H2O, before and after whole-lung lavage in rabbits. Respiratory mechanical parameters were measured, and helium-washout was used to assess end-expiratory lung volume. RESULTS: Atelectatic, poorly, normally aerated, hyperinflated, and trapped regions could be identified using the imaging technique used in this study. Surfactant depletion significantly increased atelectasis (6.3±3.3 [mean±SEM]% total lung area; P=0.04 vs. control) and poor aeration in dependent lung. Regional ventilation was distributed to poorly aerated regions with high (16.4±4.4%; P<0.001), normal (20.7±5.9%; P<0.001 vs. control), and low (5.7±1.2%; P<0.05 vs. control) specific ventilation. Significant redistribution of ventilation to normally aerated nondependent lung regions occurred (41.0±9.6%; P=0.03 vs. control). Increasing positive end-expiratory pressure level to 9 cm H2O significantly reduced poor aeration and recruited atelectasis, but ventilation redistribution persisted (39.2±9.5%; P<0.001 vs. control). CONCLUSIONS: Ventilation of poorly aerated dependent lung regions, which can promote the local concentration of mechanical stresses, was the predominant functional behavior in surfactant-depleted lung. Potential tidal recruitment of atelectatic lung regions involved a smaller fraction of the imaged lung. Significant ventilation redistribution to aerated lung regions places these at risk of increased stretch injury.


Assuntos
Respiração com Pressão Positiva , Surfactantes Pulmonares/metabolismo , Respiração Artificial , Mecânica Respiratória , Animais , Lavagem Broncoalveolar , Dióxido de Carbono/sangue , Processamento de Imagem Assistida por Computador , Pulmão/diagnóstico por imagem , Medidas de Volume Pulmonar , Masculino , Oxigênio/sangue , Atelectasia Pulmonar/fisiopatologia , Coelhos , Testes de Função Respiratória , Síncrotrons , Tomografia Computadorizada por Raios X
8.
J Appl Physiol (1985) ; 134(4): 995-1003, 2023 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-36927142

RESUMO

We analyzed the fractal dimension (Df) of lung gas and blood distribution imaged with synchrotron radiation K-edge subtraction (KES), in six anesthetized adult New Zealand White rabbits. KES imaging was performed in upright position during stable Xe gas (64% in O2) inhalation and iodine infusion (Iomeron, 350 mg/mL), respectively, at baseline and after induced bronchoconstriction by aerosolized methacholine (125 mg/mL, 90 s) and bronchodilator (salbutamol, 10 mg/mL, 90 s) inhalation, at two axial image levels. Lung Xe and iodine images were segmented, and maps of regional lung gas and blood fractions were computed. The Df of lung gas (DfXe) and blood (DfIodine) distribution was computed based on a log-log plot of variation coefficient as a function of region volume. DfXe decreased significantly during bronchoconstriction (P < 0.0001), and remained low after salbutamol. DfIodine depended on the axial image level (P < 0.0001), but did not change with bronchoconstriction. DfXe was significantly associated with arterial [Formula: see text] (R = 0.67, P = 0.002), and negatively associated with [Formula: see text] (R = -0.62, P = 0.006), respiratory resistance (R = -0.58, P = 0.011), and elastance (R = -0.55, P = 0.023). These data demonstrate the reduced Df of gas distribution during acute bronchoconstriction, and the association of this parameter with physiologically meaningful variables. This finding suggests a decreased complexity and space-filling properties of lung ventilation during bronchoconstriction, and could serve as a functional imaging biomarker in obstructive airway diseases.NEW & NOTEWORTHY Here, we used an energy-subtractive imaging technique to assess the fractal dimension (Df) of lung gas and blood distribution and the effect of acute bronchoconstriction. We found that Df of gas significantly decreases in bronchoconstriction. Conversely, Df of blood exhibits gravity-dependent changes only, and is not affected by acute bronchoconstriction. Our data show that the fractal dimension of lung gas detects the emergence of clustered rather than scattered loss of ventilatory units during bronchoconstriction.


Assuntos
Asma , Iodo , Animais , Coelhos , Broncoconstrição , Síncrotrons , Fractais , Ventilação Pulmonar/fisiologia , Pulmão , Albuterol/farmacologia , Iodo/farmacologia
9.
Cancer Biother Radiopharm ; 38(3): 184-191, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36269660

RESUMO

The authors review the results of 249 patients treated with boron neutron capture therapy (BNCT) at the Helsinki University Hospital, Helsinki, Finland, from May 1999 to January 2012 with neutrons obtained from a nuclear reactor source (FiR 1) and using l-boronophenylalanine-fructose (l-BPA-F) as the boron delivery agent. They also describe a new hospital BNCT facility that hosts a proton accelerator-based neutron source for BNCT. Most of the patients treated with nuclear reactor-derived neutrons had either inoperable, locally recurrent head and neck cancer or malignant glioma. In general, l-BPA-F-mediated BNCT was relatively well tolerated with adverse events usually similar to those of conventional radiotherapy. Twenty-eight (96.6%) out of the evaluable 29 patients with head and neck cancer and treated within a clinical trial either responded to BNCT or had tumor growth stabilization for at least 5 months, suggesting efficacy of BNCT in the treatment of this patient population. The new accelerator-based BNCT facility houses a nuBeam neutron source that consists of an electrostatic Cockcroft-Walton-type proton accelerator and a lithium target that converts the proton beam to neutrons. The proton beam energy is 2.6 MeV operating with a current of 30 mA. Treatment planning is based on Monte Carlo simulation and the RayStation treatment planning system. Patient positioning is performed with a 6-axis robotic image-guided system, and in-room imaging is done with a rail-mounted computed tomography scanner. Under normal circumstances, the personnel can enter the treatment room almost immediately after shutting down the proton beam, which improves the unit capacity. ClinicalTrials.gov ID: NCT00114790.


Assuntos
Terapia por Captura de Nêutron de Boro , Glioma , Neoplasias de Cabeça e Pescoço , Humanos , Finlândia , Prótons , Terapia por Captura de Nêutron de Boro/métodos , Glioma/tratamento farmacológico , Compostos de Boro/uso terapêutico , Neoplasias de Cabeça e Pescoço/tratamento farmacológico , Nêutrons , Reatores Nucleares
10.
Crit Care Med ; 39(7): 1731-8, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21494104

RESUMO

OBJECTIVE: To assess the effects of positive end-expiratory pressure on regional ventilation distribution in normal lung and after histamine-induced bronchoconstriction. DESIGN: Experimental study. SETTING: International research laboratory. SUBJECTS: Six healthy New Zealand rabbits weighing 2.5 ± 0.1 kg. INTERVENTIONS: Rabbits were anesthetized, tracheostomized, paralyzed, and mechanically ventilated. Synchrotron radiation computed tomography images of tissue density and specific ventilation were acquired using K-edge subtraction imaging with inhaled stable xenon gas in middle and caudal thoracic levels on 0 and 5 cm H(2)O positive end-expiratory pressure at baseline and twice after histamine inhalation. MEASUREMENTS AND MAIN RESULTS: At baseline, a positive end-expiratory pressure of 5 cm H(2)O significantly increased lung volume. Histamine inhalation caused patchy areas of decreased specific ventilation, including some areas with no ventilation. After histamine, positive end-expiratory pressure significantly increased the area of well-ventilated lung regions and decreased the heterogeneity of specific ventilation. This improvement went together with a significant but limited increase in the area of hyperinflated lung zones. CONCLUSIONS: The findings of this study suggest that in mechanically ventilated rabbit with severely heterogeneous bronchoconstriction, a positive end-expiratory pressure of 5 cm H(2)O significantly improves regional ventilation homogeneity through dilation of flow-limited airways and recruitment of closed airways.


Assuntos
Broncoconstrição/fisiologia , Pulmão/fisiopatologia , Respiração com Pressão Positiva , Ventilação Pulmonar/fisiologia , Animais , Broncoconstritores , Histamina , Pulmão/diagnóstico por imagem , Medidas de Volume Pulmonar , Masculino , Coelhos , Síncrotrons , Tomografia Computadorizada por Raios X/métodos