Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Sensors (Basel) ; 23(20)2023 Oct 12.
Artigo em Inglês | MEDLINE | ID: mdl-37896509

RESUMO

BACKGROUND: With an increasing number of systems for quantifying lameness-related movement asymmetry, between-system comparisons under non-laboratory conditions are important for multi-centre or referral-level studies. This study compares an artificial intelligence video app to a validated inertial measurement unit (IMU) gait analysis system in a specific group of horses. METHODS: Twenty-two reining Quarter horses were equipped with nine body-mounted IMUs while being videoed with a smartphone app. Both systems quantified head and pelvic movement symmetry during in-hand trot (hard/soft ground) and on the lunge (left/right rein, soft ground). Proportional limits of agreement (pLoA) were established. RESULTS: Widths of pLoA were larger for head movement (29% to 50% in-hand; 22% to 38% on lunge) than for pelvic movement (13% to 24% in-hand; 14% to 24% on lunge). CONCLUSION: The between-system pLoAs exceed current "lameness thresholds" aimed at identifying the affected limb(s) in lame horses. They also exceed published limits of agreement for stride-matched data but are similar to repeatability values and "lameness thresholds" from "non-lame" horses. This is encouraging for multi-centre studies and referral-level veterinary practice. The narrower pLoA values for pelvic movement asymmetry are particularly encouraging, given the difficulty of grading hind limb lameness "by eye".


Assuntos
Inteligência Artificial , Coxeadura Animal , Cavalos , Animais , Coxeadura Animal/diagnóstico , Fenômenos Biomecânicos , Movimento , Marcha , Movimentos da Cabeça , Extremidade Superior , Membro Posterior
2.
Methods Protoc ; 7(1)2024 Feb 04.
Artigo em Inglês | MEDLINE | ID: mdl-38392689

RESUMO

The connection between imbalances in the human gut microbiota, known as dysbiosis, and various diseases has been well established. Current techniques for sampling the small intestine are both invasive for patients and costly for healthcare facilities. Most studies on human gut microbiome are conducted using faecal samples, which do not accurately represent the microbiome in the upper intestinal tract. A pilot clinical investigation, registered as NCT05477069 and sponsored by the Grenoble Alpes University Hospital, is currently underway to evaluate a novel ingestible medical device (MD) designed for collecting small intestinal liquids by Pelican Health. This study is interventional and monocentric, involving 15 healthy volunteers. The primary objective of the study is to establish the safety and the performance of the MD when used on healthy volunteers. Secondary objectives include assessing the device's performance and demonstrating the difference between the retrieved sample from the MD and the corresponding faecal sample. Multi-omics analysis will be performed, including metagenomics, metabolomics, and culturomics. We anticipate that the MD will prove to be safe without any reported adverse effects, and we collected samples suitable for the proposed omics analyses in order to demonstrate the functionality of the MD and the clinical potential of the intestinal content.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa