Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Telemed J E Health ; 22(10): 798-808, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-27285946

RESUMO

AIMS: Recently, a permanently implantable wireless system, designed to monitor and manage pulmonary artery (PA) pressures remotely, demonstrated significant reductions in heart failure (HF) hospitalizations in high-risk symptomatic patients, regardless of ejection fraction. The objectives of this study were to simulate the estimated clinical and economic impact in Germany of generalized use of this PA pressure monitoring system considering reductions of HF hospitalizations and the improvement in Quality of Life. MATERIALS AND METHODS: Based on the Prospective Health Technology Assessment approach, we simulated the potential of the widespread application of PA pressure monitoring on the German healthcare system for the period 2009-2021. RESULTS: This healthcare economic simulation formulated input assumptions based on results from the CHAMPION Trial, a multicenter, prospective, randomized controlled U.S. trial that demonstrated a 37% reduction of hospitalizations in persistently symptomatic previous HF patients. Based on these results, an estimated 114,800 hospitalizations would expected to be avoided. This effect would potentially save an estimated €522 million, an equivalent of $575 million, during the entire simulation period. CONCLUSION: This healthcare economic modeling of the PA pressure monitoring system's impact demonstrates substantial clinical and economic benefits in the German healthcare system.


Assuntos
Monitorização Ambulatorial da Pressão Arterial/métodos , Insuficiência Cardíaca/economia , Insuficiência Cardíaca/fisiopatologia , Artéria Pulmonar , Tecnologia de Sensoriamento Remoto/métodos , Telemedicina/métodos , Idoso , Idoso de 80 Anos ou mais , Monitorização Ambulatorial da Pressão Arterial/economia , Monitorização Ambulatorial da Pressão Arterial/instrumentação , Simulação por Computador , Feminino , Alemanha , Hospitalização/economia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Qualidade de Vida , Tecnologia de Sensoriamento Remoto/economia , Tecnologia de Sensoriamento Remoto/instrumentação , Telemedicina/economia , Telemedicina/instrumentação
2.
J Am Coll Cardiol ; 56(15): 1225-34, 2010 Oct 05.
Artigo em Inglês | MEDLINE | ID: mdl-20883929

RESUMO

OBJECTIVES: This study sought to determine the prognostic value of wall motion and perfusion assessment during high-dose dobutamine stress (DS) cardiac magnetic resonance imaging (MRI) in a large patient cohort. BACKGROUND: DS-MRI offers the possibility to integrate myocardial perfusion and wall motion analysis in a single examination for the detection of coronary artery disease (CAD). METHODS: A total of 1,493 consecutive patients with suspected or known CAD underwent DS-MRI, using a standard protocol in a 1.5-T magnetic resonance scanner. Wall motion and perfusion were assessed at baseline and during stress, and outcome data including cardiac death, nonfatal myocardial infarction ("hard events"), and "late" revascularization performed >90 days after the MR scans were collected during a 2 ± 1 year follow-up period. RESULTS: Fifty-three hard events, including 14 cardiac deaths and 39 nonfatal infarctions, occurred during the follow-up period, whereas 85 patients underwent "late" revascularization. Using multivariable regression analysis, an abnormal result for wall motion or perfusion during stress yielded the strongest independent prognostic value for both hard events and late revascularization, clearly surpassing that of clinical and baseline magnetic resonance parameters (for wall motion: adjusted hazard ratio [HR] of 5.9 [95% confidence interval (CI): 2.5 to 13.6] for hard events and of 3.1 [95% CI: 1.7 to 5.6] for late revascularization, and for perfusion: adjusted HR of 5.4 [95% CI: 2.3 to 12.9] for hard events and of 6.2 [95% CI: 3.3 to 11.3] for late revascularization, p < 0.001 for all). CONCLUSIONS: DS-MRI can accurately identify patients who are at increased risk for cardiac death and myocardial infarction, separating them from those with normal findings, who have very low risk for future cardiac events. (Prognostic Value of High Dose Dobutamine Stress Magnetic Resonance Imaging; NCT00837005).


Assuntos
Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/fisiopatologia , Dobutamina/administração & dosagem , Teste de Esforço/efeitos dos fármacos , Imagem de Perfusão do Miocárdio/métodos , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Relação Dose-Resposta a Droga , Teste de Esforço/métodos , Feminino , Seguimentos , Humanos , Angiografia por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/diagnóstico , Isquemia Miocárdica/fisiopatologia , Prognóstico , Estudos Prospectivos
3.
J Magn Reson Imaging ; 17(6): 694-702, 2003 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-12766899

RESUMO

PURPOSE: To compare intraindividually gadobenate dimeglumine (Gd-BOPTA) with gadopentetate dimeglumine (Gd-DTPA) for multi-station MR Angiography of the run-off vessels. MATERIALS AND METHODS: Twenty-one randomized healthy volunteers received either Gd-BOPTA or Gd-DTPA as a first injection and then the other agent as a second injection after a minimum interval of 6 days. Each agent was administered at a dose of 0.1 mmol/kg bodyweight followed by a 25-mL saline flush at a single constant flow rate of 0.8 mL/second. Images were acquired sequentially at the level of the pelvis, thigh, and calf using a fast three-dimensional (3D) gradient echo sequence. Source, subtracted source, maximum intensity projection (MIP), and subtracted MIP image sets from each examination were evaluated quantitatively and qualitatively on a segmental basis involving nine vascular segments. RESULTS: Significantly (P < 0.05) higher signal-to-noise and contrast-to-noise ratios were noted for Gd-BOPTA compared to Gd-DTPA, with the more pronounced differences evident in the more distal vessels. Qualitative assessmentrevealed no differences in the abdominal vasculature, a preference for Gd-BOPTA in the pelvic vasculature, and markedly better performance for Gd-BOPTA in the femoral and tibial vasculature. Summation of individual diagnostic quality scores for each segment revealed a significantly (P = 0.0001) better performance for Gd-BOPTA compared to Gd-DTPA. CONCLUSION: Greater vascular enhancement of the run-off vasculature is obtained after Gd-BOPTA, particularly in the smaller more distal vessels. Enhancement differences are not merely dose dependent, but may be due to different vascular enhancement characteristics of the agents.


Assuntos
Meios de Contraste/administração & dosagem , Gadolínio DTPA , Angiografia por Ressonância Magnética/métodos , Meglumina/análogos & derivados , Compostos Organometálicos , Adulto , Análise de Variância , Aorta Abdominal/anatomia & histologia , Método Duplo-Cego , Feminino , Artéria Femoral/anatomia & histologia , Gadolínio DTPA/efeitos adversos , Humanos , Aumento da Imagem , Perna (Membro)/irrigação sanguínea , Masculino , Meglumina/efeitos adversos , Compostos Organometálicos/efeitos adversos , Pelve/irrigação sanguínea , Artéria Poplítea/anatomia & histologia , Valores de Referência , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa