Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Microorganisms ; 12(7)2024 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-39065152

RESUMO

Culture-positive (CP) and culture-negative (CN) periprosthetic joint infections (PJI) remain a crucial area of research; however, current studies comparing these infections rely on unstandardized outcome reporting tools. Our study aimed to compare the outcomes of two-stage revision of CP and CN PJI using the standardized Musculoskeletal Infection Society (MSIS) outcome reporting tool. We retrospectively reviewed 138 patients who were diagnosed with PJI and indicated for two-stage revision total knee arthroplasty (rTKA). The majority of patients in both CP and CN cohorts achieved infection control without the need for reoperation (54.1% and 62.5%, respectively). There was a significant difference in the overall distribution of MSIS outcomes (p = 0.043), with a significantly greater rate of CN patients falling into Tier 1 (infection control without the use of suppressive antibiotics) (52.5% versus 29.6%, p = 0.011). There was also a significant difference in the distribution of septic versus aseptic reoperations after 2nd stage (p = 0.013), with more CP reoperations being septic and more CN reoperations being aseptic. The duration from first to second stage was significantly shorter in the CN cohort (p = 0.002). While overall infection control was similar between cohorts, these data suggest that the outcomes of two-stage rTKA are favorable in cases of CN PJI.

2.
Adv Orthop ; 2024: 4125965, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38264013

RESUMO

Introduction: Dual-mobility (DM) implants for total hip arthroplasty (THA) have gained popularity due to their potential to reduce hip instability and dislocation events that may lead to revision surgery. These implants consist of a femoral head articulated within a polyethylene liner, which articulates within an outer acetabular shell, creating a dual-bearing surface. Our study aimed to report our observations on the survivorship of a novel DM implant for primary total hip arthroplasty at two years. Methods: We conducted a retrospective, multicenter study to assess the clinical outcomes of patients undergoing a THA with a novel DM implant (OR3O acetabular system™, Smith & Nephew, Inc., Memphis, TN) from January 2020 to September 2021. Patient demographics, surgical information, and survivorship data were collected from medical records for patients with a minimum of two years of follow-up. Primary outcomes included overall implant survivorship at two years as well as aseptic survivorship, revision rates of the DM acetabular shell, and average time to revision. Patient-reported outcomes were collected in the form of HOOS JR. Results: A total of 250 hips in 245 patients had a minimum two-year follow-up. Primary osteoarthritis (80%) was the most common indication for index THA. The average aseptic survivorship of the DM acetabular components at two years for the cohort was 98.4% and survivorship of the acetabular implants overall was 97.6%. There were a total of four (1.6%) aseptic revisions of the DM acetabular component. Reasons for aseptic acetabular revision included one case of instability, one intraprosthetic dislocation, one periprosthetic acetabular fracture, and one malpositioned acetabular cup resulting in impingement. The mean time of follow-up was 893.9 days. Eighty-seven patients had preoperative and two-year HOOS JR available. HOOS JR improved by an average of 38.5 points. Conclusion: This novel DM acetabular implant demonstrates excellent survivorship at two years follow-up with low rates of instability and intraprosthetic dislocation and no episodes of metal-on-metal corrosion. Use of the DM implant demonstrated clinically relevant improvements in patient-reported outcomes at two years.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa