Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
J Proteome Res ; 23(4): 1443-1457, 2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38450643

RESUMO

We report the comparison of mass-spectral-based abundances of tryptic glycopeptides to fluorescence abundances of released labeled glycans and the effects of mass and charge state and in-source fragmentation on glycopeptide abundances. The primary glycoforms derived from Rituximab, NISTmAb, Evolocumab, and Infliximab were high-mannose and biantennary complex galactosylated and fucosylated N-glycans. Except for Evolocumab, in-source ions derived from the loss of HexNAc or HexNAc-Hex sugars are prominent for other therapeutic IgGs. After excluding in-source fragmentation of glycopeptide ions from the results, a linear correlation was observed between fluorescently labeled N-glycan and glycopeptide abundances over a dynamic range of 500. Different charge states of human IgG-derived glycopeptides containing a wider variety of abundant attached glycans were also investigated to examine the effects of the charge state on ion abundances. These revealed a linear dependence of glycopeptide abundance on the mass of the glycan with higher charge states favoring higher-mass glycans. Findings indicate that the mass spectrometry-based bottom-up approach can provide results as accurate as those of glycan release studies while revealing the origin of each attached glycan. These site-specific relative abundances are conveniently displayed and compared using previously described glycopeptide abundance distribution spectra "GADS" representations. Mass spectrometry data are available from the MAssIVE repository (MSV000093562).


Assuntos
Imunoglobulina G , Espectrometria de Massas em Tandem , Humanos , Glicosilação , Glicopeptídeos/análise , Polissacarídeos/química , Íons
2.
J Proteome Res ; 21(10): 2421-2434, 2022 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-36112477

RESUMO

We present a mass spectral library-based method for analyzing site-specific N-linked protein glycosylation. Its operation and utility are illustrated by applying it to both newly measured and available proteomics data of human milk glycoproteins. It generates two varieties of mass spectral libraries. One contains glycopeptide abundance distribution spectra (GADS). The other contains tandem mass spectra of the underlying glycopeptides. Both originate from identified glycopeptides in proteolytic digests of human milk and purified glycoproteins, which include tenascin, lactoferrin, and several antibodies. Analysis was also applied to digests of a NIST human milk standard reference material (SRM), leading to a GADS library of N-glycopeptides, enabling the direct comparison of glycopeptide distributions for individual proteins. Tandem spectra underlying each glycopeptide GADS peak are combined to create a second type of library that contains spectra of the underlying glycopeptide spectra. These were acquired by higher-energy (stepped) collision dissociation fragmentation followed by ion-trap fragmentation. Spectra are annotated using MS_Piano, recently reported annotation software. This data, with extensions of a widely used spectral library search and display software, provides accessible mass spectral libraries.


Assuntos
Proteínas do Leite , Leite Humano , Glicopeptídeos/análise , Glicoproteínas/metabolismo , Glicosilação , Humanos , Lactoferrina/metabolismo , Proteínas do Leite/metabolismo , Leite Humano/química , Tenascina/metabolismo
3.
J Proteome Res ; 20(9): 4475-4486, 2021 09 03.
Artigo em Inglês | MEDLINE | ID: mdl-34327998

RESUMO

A method for representing and comparing distributions of N-linked glycans located at specific sites on proteins is presented. The representation takes the form of a simple mass spectrum for a given peptide sequence, with each peak corresponding to a different glycopeptide. The mass (in place of m/z) of each peak is that of the glycan mass, and its abundance corresponds to its relative abundance in the electrospray MS1 spectrum. This provides a facile means of representing all identifiable glycopeptides arising from a single protein "sequon" on a specific sequence, thereby enabling the comparison and searching of these distributions as routinely done for mass spectra. Likewise, these reference glycopeptide abundance distribution spectra (GADS) can be stored in searchable libraries. A set of such libraries created from available data is provided along with an adapted version of the widely used NIST-MS library-search software. Since GADS contain only MS1 abundances and identifications, they are equally suitable for expressing collision-induced fragmentation and electron-transfer dissociation determinations of glycopeptide identity. Comparisons of GADS for N-glycosylated sites on several proteins, especially the SARS-CoV-2 spike protein, demonstrate the potential reproducibility of GADS and their utility for comparing site-specific distributions.


Assuntos
COVID-19 , Glicopeptídeos/metabolismo , Glicoproteínas , Glicosilação , Humanos , Polissacarídeos , Reprodutibilidade dos Testes , SARS-CoV-2 , Glicoproteína da Espícula de Coronavírus
4.
J Proteome Res ; 20(3): 1612-1629, 2021 03 05.
Artigo em Inglês | MEDLINE | ID: mdl-33555887

RESUMO

This work presents methods for identifying and then creating a mass spectral library for disulfide-linked peptides originating from the NISTmAb, a reference material of the humanized IgG1k monoclonal antibody (RM 8671). Analyses involved both partially reduced and non-reduced samples under neutral and weakly basic conditions followed by nanoflow liquid chromatography tandem mass spectrometry (LC-MS/MS). Spectra of peptides containing disulfide bonds are identified by both MS1 ion and MS2 fragment ion data in order to completely map all the disulfide linkages in the NISTmAb. This led to the detection of 383 distinct disulfide-linked peptide ions, arising from fully tryptic cleavage, missed cleavage, irregular cleavage, complex Met/Trp oxidation mixtures, and metal adducts. Fragmentation features of disulfide bonds under low-energy collision dissociation were examined. These include (1) peptide bond cleavage leaving disulfide bonds intact; (2) disulfide bond cleavage, often leading to extensive fragmentation; and (3) double cleavage products resulting from breakages of two peptide bonds or both peptide and disulfide bonds. Automated annotation of various complex MS/MS fragments enabled the identification of disulfide-linked peptides with high confidence. Peptides containing each of the nine native disulfide bonds were identified along with 86 additional disulfide linkages arising from disulfide bond shuffling. The presence of shuffled disulfides was nearly completely abrogated by refining digest conditions. A curated spectral library of 702 disulfide-linked peptide spectra was created from this analysis and is publicly available for free download. Since all IgG1 antibodies have the same constant regions, the resulting library can be used as a tool for facile identification of "hard-to-find" disulfide-bonded peptides. Moreover, we show that one may identify such peptides originating from IgG1 proteins in human serum, thereby serving as a means of monitoring the completeness of protein reduction in proteomics studies. Data are available via ProteomeXchange with identifier PXD023358.


Assuntos
Peptídeos , Espectrometria de Massas em Tandem , Sequência de Aminoácidos , Cromatografia Líquida , Dissulfetos , Humanos
5.
J Proteome Res ; 20(9): 4603-4609, 2021 Sep 03.
Artigo em Inglês | MEDLINE | ID: mdl-34264676

RESUMO

Annotating product ion peaks in tandem mass spectra is essential for evaluating spectral quality and validating peptide identification. This task is more complex for glycopeptides and is crucial for the confident determination of glycosylation sites in glycoproteins. MS_Piano (Mass Spectrum Peptide Annotation) software was developed for reliable annotation of peaks in collision induced dissociation (CID) tandem mass spectra of peptides or N-glycopeptides for given peptide sequences, charge states, and optional modifications. The program annotates each peak in high or low resolution spectra with possible product ion(s) and the mass difference between the measured and theoretical m/z values. Spectral quality is measured by two major parameters: the ratio between the sum of unannotated vs all peak intensities in the top 20 peaks, and the intensity of the highest unannotated peak. The product ions of peptides, glycans, and glycopeptides in spectra are labeled in different class-type colors to facilitate interpretation. MS_Piano assists validating peptide and N-glycopeptide identification from database and library searches and provides quality control and optimizes search reliability in custom developed peptide mass spectral libraries. The software is freely available in .exe and .dll formats for the Windows operating system.


Assuntos
Glicopeptídeos , Proteômica , Reprodutibilidade dos Testes , Software , Espectrometria de Massas em Tandem
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa