Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 201
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Surg Endosc ; 38(2): 999-1004, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38017159

RESUMO

BACKGROUND: The ability to ambulate is an important indicator for wellness and quality of life. A major health event, such as a surgery, can derail this ability, and return to preoperative walking ability is a marker for recovery. Self-reported walking measurements by patients are subject to bias, thus wearable technology such as activity monitors have risen in popularity. We evaluated postoperative ambulation using an accelerometer in outpatient general surgery procedures with the hypothesis that those patients with less postoperative ambulation were at risk for adverse outcomes. METHODS: A retrospective review of patients undergoing outpatient abdominal surgeries from November 2016 to July 2019 at a Veteran Affairs Medical Center. Patients wore an accelerometer preoperatively and postoperatively to measure their ambulation (steps/day). Outcome measures were 30-day readmissions and Emergency Department (ED) utilization. Postoperative ambulation was defined as daily percentages of their preoperative baseline. Patients without preoperative baseline data, > 3 missing days or any missing days prior to reaching baseline were excluded. RESULTS: One-hundred-six patients underwent outpatient abdominal surgery. Twenty-two patients were excluded. Patients stratified into adult (18-64 years, 44 patients, 52%) and geriatric (≥ 65 years, 40 patients, 48%) cohorts. Geriatric patients were less likely to meet their preoperative baseline by postoperative day 7, 35% vs 61%, p = 0.016. Adult patients who failed to meet their preoperative baseline in first postoperative week had higher ED utilization; 4 (24%) vs 1 (4%), p = 0.04. Geriatric patients who failed to meet their baseline trended toward increased ED utilization; 5 (19%) vs. 1 (7%), p = 0.31. CONCLUSION: Patients aged < 65 who fail to return to their preoperative daily step count within one week of outpatient abdominal surgery are 6× more likely to be seen in the ED. Postoperative ambulation may be able to predict ED utilization and recovery after outpatient surgery.


Assuntos
Procedimentos Cirúrgicos Ambulatórios , Qualidade de Vida , Adulto , Humanos , Idoso , Caminhada , Estudos Retrospectivos , Serviço Hospitalar de Emergência , Complicações Pós-Operatórias/etiologia
2.
J Surg Res ; 287: 186-192, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36940640

RESUMO

INTRODUCTION: Telehealth has been increasingly utilized with a renewed interest by surgical specialties given the COIVD-19 pandemic. Limited data exists evaluating the safety of routine postoperative telehealth follow-up in patients undergoing inguinal hernia repair, especially those who present urgent/emergently. Our study sought to evaluate the safety and efficacy of postoperative telehealth follow-up in veterans undergoing inguinal hernia repair. METHODS: Retrospective review of all Veterans who underwent inguinal hernia repair at a tertiary Veterans Affairs Medical Center over a 2-year period (9/2019-9/2021). Outcome measures included postoperative complications, emergency department (ED) utilization, 30-day readmission, and missed adverse events (ED utilization or readmission occurring after routine postoperative follow-up). Patients undergoing additional procedure(s) requiring intraoperative drains and/or nonabsorbable sutures were excluded. RESULTS: Of 338 patients who underwent qualifying procedures, 156 (50.6%) were followed-up by telehealth and 152 (49.4%) followed-up in-person. There were no differences in age, sex, BMI, race, urgency, laterality nor admission status. Patients with higher American Society of Anesthesiologists (ASA) classification [ASA class III 92 (60.5%) versus class II 48 (31.6%), P = 0.019] and open repair [93 (61.2%) versus 67 (42.9%), P = 0.003] were more likely to follow-up in-person. There was no difference in complications, [telehealth 13 (8.3%) versus 20 (13.2%), P = 0.17], ED visits, [telehealth 15 (10%) versus 18 (12%), P = 0.53], 30-day readmission [telehealth 3 (2%) versus 0 (0%), P = 0.09], nor missed adverse events [telehealth 6 (33.3%) versus 5 (27.8%), P = 0.72]. CONCLUSIONS: There were no differences in postoperative complications, ED utilization, 30-day readmission, or missed adverse events for those who followed-up in person versus telehealth after elective or urgent/emergent inguinal hernia repair. Veterans with a higher ASA class and who underwent open repair were more likely to be seen in person. Telehealth follow-up after inguinal hernia repair is safe and effective.


Assuntos
Hérnia Inguinal , Laparoscopia , Telemedicina , Veteranos , Humanos , Seguimentos , Hérnia Inguinal/cirurgia , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/cirurgia , Estudos Retrospectivos , Herniorrafia/efeitos adversos , Herniorrafia/métodos , Laparoscopia/métodos
3.
Surg Endosc ; 37(1): 580-586, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-35612638

RESUMO

INTRODUCTION: Stray energy from surgical energy instruments can cause unintended thermal injuries. There are no published data regarding electrosurgical generators and their influence on stray energy transfer during robotic surgery. There are two approved generators for the DaVinci Xi robotic platform: a constant-voltage regulating generator (cVRG) and a constant-power regulating generator (cPRG). The purpose of this study was to quantify and compare stray energy transfer in the robotic Xi platform using a cVRG versus a cPRG. METHODS: An ex vivo bovine model was used to simulate a standard multiport robotic surgery. The DaVinci Xi (Intuitive Surgical, Sunnyvale, CA) robotic platform was attached to a trainer box using robotic ports. A 5 s, open-air activation of the monopolar scissors was done with commonly used electrosurgical settings using a cPRG (ForceTriad, Covidien-Medtronic, Boulder, CO) or cVRG (ERBE VIO 300 dV 2.0, ERBE USA, Marietta, GA). Stray energy transfer was quantified as the change in tissue temperature (°C) nearest the tip of the assistance grasper (which was not in direct contact with the active monopolar scissors). RESULTS: Stray energy transfer occurred with both generators. Utilizing common, comparable settings for standard coagulation, significantly less stray energy was transferred with the cVRG versus cPRG (4.4 ± 1.6 °C vs. 41.1 ± 13.0 °C, p < 0.001). Similarly, less stray energy was transferred using cut modes with the cVRG compared to the cPRG (5.61 ± 1.79 °C vs. 33.9 ± 18.4 °C, p < 0.001). CONCLUSION: Stray energy transfer increases tissue temperatures more than 45C in the DaVinci Xi robotic platform. Low voltage modalities, such as cut or blend; as well as a cVRG generator, significantly reduces stray energy. Robotic surgeons can minimize the risk of stray energy injuries by using these low risk modes and/or generator.


Assuntos
Queimaduras , Procedimentos Cirúrgicos Robóticos , Robótica , Humanos , Animais , Bovinos , Eletrocirurgia
4.
Surg Endosc ; 37(11): 8771-8777, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37580577

RESUMO

BACKGROUND: Stray energy transfer from monopolar instruments during laparoscopic surgery is a recognized cause of potentially catastrophic complications. There are limited data on stray energy injuries in robotic surgery. We sought to characterize stray energy injury in the form of superficial burns to the skin surrounding laparoscopic and robotic trocar sites. Our hypothesis was that stray energy burns will occur at all laparoscopic and robotic port sites. METHODS: We conducted a prospective, randomized controlled trial of patients undergoing elective unilateral inguinal hernia repair at a VAMC over a 4-year period. Surgery was performed via transabdominal preperitoneal approach either laparoscopic-assisted (TAPP) or robotic-assisted (rTAPP). A monopolar scissor was used to deliver energy at 30W coagulation for all cases. At completion of the procedure, skin biopsies were taken from all the port sites. A picro-Sirius red stain was utilized to identify thermal injury by a blinded pathologist. RESULTS: Over half (54%, 59/108) of all samples demonstrated thermal injury to the skin. In the laparoscopic group, 49% (25/51) samples showed thermal injury vs. 60% (34/57) in the robotic group (p = 0.548). The camera port was the most frequently involved with 68% (13/19) rTAPP samples showing injury vs. 47% (8/17) in the TAPP group (p = 0.503). There was no difference in the rate of injury at the working port site (rTAPP 53%, 10/19 vs. TAPP 47%, 8/17; p = 0.991) or the assistant port site (rTAPP 58%, 11/19 vs. TAPP 53%, 9/17; p = 0.873). CONCLUSIONS: Stray energy causes thermal injury to the skin at port sites in the majority robotic laparoscopic TAPP inguinal hernia repairs. There is no difference in stray energy transfer between the laparoscopic and robotic platform. This is the first study to confirm in-vivo transfer of stray energy during robotic surgical procedures. More study is needed to determine the clinical significance of these thermal injuries.


Assuntos
Queimaduras , Hérnia Inguinal , Laparoscopia , Procedimentos Cirúrgicos Robóticos , Humanos , Hérnia Inguinal/cirurgia , Laparoscopia/efeitos adversos , Laparoscopia/métodos , Estudos Prospectivos , Procedimentos Cirúrgicos Robóticos/efeitos adversos , Procedimentos Cirúrgicos Robóticos/métodos , Telas Cirúrgicas
5.
Surg Endosc ; 37(4): 3201-3207, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-35974252

RESUMO

BACKGROUND: The COVID-19 pandemic has brought many challenges including barriers to delivering high-quality surgical care and follow-up while minimizing the risk of infection. Telehealth has been increasingly utilized for post-operative visits, yet little data exists to guide surgeons in its use. We sought to determine safety and efficacy of telehealth follow-up in patients undergoing cholecystectomy during the global pandemic at a VA Medical Center (VAMC). METHODS: This was a retrospective review of patients undergoing cholecystectomy at a level 1A VAMC over a 2-year period from August 2019 to August 2021. Baseline demographics, post-operative complications, readmissions, emergency department (ED) visits and need for additional procedures were reviewed. Patients who experienced a complication prior to discharge, underwent a concomitant procedure, had non-absorbable skin closure, had new diagnosis of malignancy or were discharged home with drain(s) were ineligible for telehealth follow-up and excluded. RESULTS: Over the study period, 179 patients underwent cholecystectomy; 30 (17%) were excluded as above. 20 (13%) missed their follow-up, 52 (35%) were seen via telehealth and 77 (52%) followed-up in person. There was no difference between the two groups regarding baseline demographics or intra-operative variables. There was no significant difference in post-operative complications [4 (8%) vs 6 (8%), p > 0.99], ED utilization [5 (10%) vs 7 (9%), p = 0.78], 30-day readmission [3 (6%) vs 6 (8%), p = 0.74] or need for additional procedures [2 (4%) vs 4 (5%), p = 0.41] between telehealth and in-person follow-up. CONCLUSION: Telehealth follow-up after cholecystectomy is safe and effective in Veterans. There were no differences in outcomes between patients that followed up in-person vs those that were seen via phone or video. Routine telehealth follow-up after uncomplicated cholecystectomy should be considered for all patients.


Assuntos
COVID-19 , Telemedicina , Veteranos , Humanos , COVID-19/epidemiologia , Seguimentos , Pandemias , Colecistectomia , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/prevenção & controle
6.
Child Dev ; 94(1): 303-314, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36056573

RESUMO

This prospective, longitudinal study examined associations between whether and when children first acquire a mobile phone and their adjustment measures, among low-income Latinx children. Children (N = 263; 55% female; baseline Mage  = 9.5) and their parents were assessed annually for 5 years from 2012. Children first acquired a mobile phone at a mean (SD) age of 11.62 (1.41) years. Pre-registered multilevel models tested associations linking phone ownership, phone acquisition age, and the interaction between ownership and acquisition age to levels and changing trends of depressive symptoms, school grades, and reported and objectively assessed sleep. Results showed no statistically significant associations, controlling the False Discovery Rate. Findings suggest an absence of meaningful links from mobile phone ownership and acquisition age to child adjustment.


Assuntos
Telefone Celular , Propriedade , Humanos , Criança , Feminino , Masculino , Estudos Prospectivos , Estudos Longitudinais , Hispânico ou Latino
7.
Multivariate Behav Res ; : 1-9, 2023 Jul 13.
Artigo em Inglês | MEDLINE | ID: mdl-37439508

RESUMO

Advances in ability to comprehensively record individuals' digital lives and in AI modeling of those data facilitate new possibilities for describing, predicting, and generating a wide variety of behavioral processes. In this paper, we consider these advances from a person-specific perspective, including whether the pervasive concerns about generalizability of results might be productively reframed with respect to transferability of models, and how self-supervision and new deep neural network architectures that facilitate transfer learning can be applied in a person-specific way to the super-intensive longitudinal data arriving in the Human Screenome Project. In developing the possibilities, we suggest Molenaar add a statement to the person-specific Manifesto - "In short, the concerns about generalizability commonly leveled at the person-specific paradigm are unfounded and can be fully and completely replaced with discussion and demonstrations of transferability."

8.
Surg Endosc ; 36(9): 6647-6652, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35022829

RESUMO

BACKGROUND: The Fundamental Use of Surgical Energy (FUSE) program was developed by The Society of American Gastrointestinal and Endoscopic Surgeons (SAGES) to promote the safe use of surgical energy. A curriculum that could be used in hospital educational programs was needed to expand access. The goal of this project was to develop a short, inexpensive, online module that emphasizes key FUSE learning objectives. The accompanying survey assessed perceived relevancy. METHODS: The SAGES FUSE Committee developed the Hospital Compliance Module. The target audience included all OR personnel. The Module was piloted at Beth Israel Deaconess Medical Center. The data were analyzed using Chi-square with Yates' correction two-tailed test. RESULTS: Three-hundred-eighty individuals completed the survey: 198 (52%) surgeons, 139 (37%) nurses, 28 (7%) surgical technicians, and 15 (4%) house staff. For "…the Module taught me valuable information" 155 (41%) responded extremely and 350 (92%) responded at least somewhat. For "As a result of [the Module] how likely are you to change how you set up or use energy devices…?" 103 (27%) responded extremely and 305 (80%) responded at least somewhat. For "How likely are you to recommend this compliance module…?" 143 (38%) responded extremely and 333 (88%) responded at least somewhat. CONCLUSION: The FUSE Hospital Compliance Module is effective and efficient. It should be considered for widespread distribution by hospitals to enhance staff education.


Assuntos
Competência Clínica , Salas Cirúrgicas , Currículo , Eletrocirurgia , Hospitais , Humanos , Estados Unidos
9.
Surg Endosc ; 36(7): 4828-4833, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-34755234

RESUMO

BACKGROUND: Recovery of preoperative ambulation levels 1 month after surgery represents an important patient-centered outcome. The objective of this study is to identify clinical factors associated with the inability to regain baseline preoperative ambulation levels 28 days postoperatively. METHODS: This is a prospective cohort study enrolling patients scheduled for elective inpatient abdominal operations. Daily ambulation (steps/day) was measured with a wristband accelerometer. Preoperative steps were recorded for at least 3 full calendar days before surgery. Postoperatively, daily steps were recorded for at least 28 days. The primary outcome was delayed recovery of ambulation, defined as inability to achieve 50% of preoperative baseline steps at 28 days postoperatively. RESULTS: A total of 108 patients were included. Delayed recovery (< 50% of baseline preoperative steps/day) occurred in 32 (30%) patients. Clinical factors associated with delayed recovery after multivariable logistic regression included longer operative time (OR 1.37, 95% CI 1.05-1.79), open operative approach (OR 4.87, 95% CI 1.64-14.48) and percent recovery on POD3 (OR 0.73, 95% CI 0.56-0.96). In addition, patients with delayed ambulation recovery had increased rates of postoperative complications (16% vs 1%, p < 0.01) and readmission (28% vs 5%, p < 0.01). CONCLUSION: After elective inpatient abdominal operations, nearly one in three patients do not recover 50% of their baseline preoperative steps 28 days postoperatively. Factors that can be used to identify these patients include longer operations, open operations and low ambulation levels on postoperative day #3. These data can be used to target rehabilitation efforts aimed at patients at greatest risk for poor ambulatory recovery.


Assuntos
Abdome , Procedimentos Cirúrgicos Eletivos , Abdome/cirurgia , Deambulação Precoce/efeitos adversos , Procedimentos Cirúrgicos Eletivos/efeitos adversos , Humanos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/cirurgia , Período Pós-Operatório , Estudos Prospectivos , Caminhada
10.
Surg Endosc ; 36(9): 6969-6974, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35132448

RESUMO

INTRODUCTION: Enteral access is required for a variety of reasons from neuromuscular disorders to dysphagia. Gastrostomy tubes (GTs) can be placed endoscopically, surgically, or radiographically and complications include infection, bleeding, leakage and unintentional removal. Routine post-procedural follow-up is limited by inconsistent guidelines and management by different specialty teams. We established a dedicated GT clinic to provide continuity of care and prophylactic GT exchange. We hypothesized that patients followed in the GT clinic would have reduced Emergency Department (ED) utilization. METHODS: A retrospective review of patients who underwent GT placement from January 2010 to January 2020 was conducted. Baseline demographics, indications for GT placement, number and reason for ED visits and utilization of a multidisciplinary GT clinic were studied. RESULTS: A total of 97 patients were included. The most common indication for placement was dysphagia (88, 91%) and the most common primary diagnosis was head and neck malignancy (51, 51%). The GT clinic is a multidisciplinary clinic staffed by surgeons and residents, dieticians, and wound care specialists and cared for 16 patients in this study. Three patients (19%) in the GT clinic group required ED visits compared to 44 (54%) in the standard of care (SOC) group (p < 0.05). There was an average of 0.9 ED visits per patient (range 0-7) in the GT clinic group vs 1.6 ED visits per patient (range 0-20) in the SOC group (p = 0.34). Feeding tubes were prophylactically exchanged an average of 7 times per patient in the GT clinic group vs 3 times per patient in the SOC group (p < 0.05). CONCLUSION: A multidisciplinary clinic dedicated to GT care limits ED visits for associated complications by more than 50%. Follow-up in a dedicated clinic with prophylactic tube exchange decreases ED visits and should be considered at facilities that care for patients with GTs.


Assuntos
Transtornos de Deglutição , Gastrostomia , Transtornos de Deglutição/etiologia , Transtornos de Deglutição/terapia , Serviço Hospitalar de Emergência , Nutrição Enteral , Gastrostomia/efeitos adversos , Humanos , Intubação Gastrointestinal , Estudos Retrospectivos
11.
Br J Nutr ; 126(1): 81-91, 2021 07 14.
Artigo em Inglês | MEDLINE | ID: mdl-32993818

RESUMO

Few studies have derived data-driven dietary patterns in youth in the USA. This study examined data-driven dietary patterns and their associations with BMI measures in predominantly low-income, racial/ethnic minority US youth. Data were from baseline assessments of the four Childhood Obesity Prevention and Treatment Research (COPTR) Consortium trials: NET-Works (534 2-4-year-olds), GROW (610 3-5-year-olds), GOALS (241 7-11-year-olds) and IMPACT (360 10-13-year-olds). Weight and height were measured. Children/adult proxies completed three 24-h dietary recalls. Dietary patterns were derived for each site from twenty-four food/beverage groups using k-means cluster analysis. Multivariable linear regression models examined associations of dietary patterns with BMI and percentage of the 95th BMI percentile. Healthy (produce and whole grains) and Unhealthy (fried food, savoury snacks and desserts) patterns were found in NET-Works and GROW. GROW additionally had a dairy- and sugar-sweetened beverage-based pattern. GOALS had a similar Healthy pattern and a pattern resembling a traditional Mexican diet. Associations between dietary patterns and BMI were only observed in IMPACT. In IMPACT, youth in the Sandwich (cold cuts, refined grains, cheese and miscellaneous) compared with Mixed (whole grains and desserts) cluster had significantly higher BMI (ß = 0·99 (95 % CI 0·01, 1·97)) and percentage of the 95th BMI percentile (ß = 4·17 (95 % CI 0·11, 8·24)). Healthy and Unhealthy patterns were the most common dietary patterns in COPTR youth, but diets may differ according to age, race/ethnicity or geographic location. Public health messages focused on healthy dietary substitutions may help youth mimic a dietary pattern associated with lower BMI.


Assuntos
Índice de Massa Corporal , Dieta , Minorias Étnicas e Raciais , Obesidade Infantil , Adolescente , Criança , Pré-Escolar , Estudos Transversais , Etnicidade , Comportamento Alimentar , Humanos , Grupos Minoritários , Obesidade Infantil/prevenção & controle , Estados Unidos
12.
Surg Endosc ; 35(7): 3796-3801, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-32804270

RESUMO

INTRODUCTION: More than 3 million patients have a cardiac implanted electronic device (CIED) such as a pacemaker or implanted cardioverter-defibrillator in the USA. These devices are susceptible to electromagnetic interference (EMI) leading to malfunction and injury. Radiofrequency energy, the most common modality for obtaining hemostasis during endoscopy, is the most common source of EMI. Few studies have evaluated the effect of endoscopic radiofrequency energy on CIEDs. We aim to characterize CIED dysfunction related to endoscopic procedures. We hypothesize that EMI from endoscopic energy can result in patient injury. METHODS: We queried the Manufacturer and User Facility Device Experience (MAUDE) database for CIED dysfunction related to electrosurgical devices over a 10-year period (2009-2019). CIED dysfunction events were identified using seven problem codes (malfunction, electromagnetic interference, ambient noise, pacing problem, over-sensing, inappropriate shock, defibrillation). These were cross-referenced for the terms "cautery, electrocautery, endoscopy, esophagus, colonoscopy, colon, esophagoscopy, and esophagogastroduodenoscopy." Reports were individually reviewed to confirm and characterize CIED malfunction due to an endoscopic procedure. RESULTS: A search for CIED dysfunction resulted in 43,759 reports. Three hundred and eleven reports (0.7%) were associated with electrocautery, and of these, 45 reports (14.5%) included endoscopy. Ten reports involving endoscopy (22%) specified upper (3, 7%) or lower (7, 16%) endoscopy while the remainder were non-specific. Twenty-six of reports involving endoscopy (58%) suffered injury because of CIED dysfunction: Of these, 17 (65%) received inappropriate shocks, 5 (19%) had pacing inhibition with bradycardia or asystole, 3 (12%) had CIED damage requiring explant and replacement, and 1 (4%) patient suffered ventricular tachycardia requiring hospital admission. CONCLUSION: The use of energy during endoscopy can cause dysfunction of CIEDs. This most commonly results in inappropriate defibrillation, symptomatic bradycardia, and asystole. Patients with CIEDs undergoing endoscopy should undergo pre- and post-procedure device interrogation and re-programming to avoid patient injury.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Preparações Farmacêuticas , Desfibriladores Implantáveis/efeitos adversos , Fenômenos Eletromagnéticos , Endoscopia , Humanos , Marca-Passo Artificial/efeitos adversos
13.
Surg Endosc ; 35(5): 2084-2090, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-32385708

RESUMO

INTRODUCTION: Stray energy transfer from monopolar radiofrequency energy during laparoscopy can be potentially catastrophic. Robotic surgery is increasing in popularity; however, the risk of stray energy transfer during robotic surgery is unknown. The purpose of this study was to (1) quantify stray energy transfer using robotic instrumentation, (2) determine strategies to minimize the transfer of energy, and (3) compare robotic stray energy transfer to laparoscopy. METHODS: In a laparoscopic trainer, a monopolar instrument (L-hook) was activated with DaVinci Si (Intuitive, Sunnyvale, CA) robotic instruments. A camera and assistant grasper were inserted to mimic a minimally invasive cholecystectomy. During activation of the L-hook, the non-electric tips of the camera and grasper were placed adjacent to simulated tissue (saline-soaked sponge). The primary outcome was change in temperature from baseline (°C) measured nearest the tip of the non-electric instrument. RESULTS: Simulated tissue nearest the robotic grasper increased an average of 18.3 ± 5.8 °C; p < 0.001 from baseline. Tissue nearest the robotic camera tip increased (9.0 ± 2.1 °C; p < 0.001). Decreasing the power from 30 to 15 W (18.3 ± 5.8 vs. 2.6 ± 2.7 °C, p < 0.001) or using low-voltage cut mode (18.3 ± 5.8 vs. 3.1 ± 2.1 °C, p < 0.001) reduced stray energy transfer to the robotic grasper. Desiccating tissue, in contrast to open air activation, also significantly reduced stray energy transfer for the grasper (18.3 ± 5.8 vs. 0.15 ± 0.21 °C, p < 0.001) and camera (9.0 ± 2.1 vs. 0.24 ± 0.34 °C, p < 0.001). CONCLUSIONS: Stray energy transfer occurs during robotic surgery. The assistant grasper carries the highest risk for thermal injury. Similar to laparoscopy, stray energy transfer can be reduced by lowering the power setting, utilizing a low-voltage cut mode instead of coagulation mode and avoiding open air activation. These practical findings can aid surgeons performing robotic surgery to reduce injuries from stray energy.


Assuntos
Procedimentos Cirúrgicos Robóticos/efeitos adversos , Procedimentos Cirúrgicos Robóticos/instrumentação , Ar , Queimaduras/etiologia , Transferência de Energia , Humanos , Laparoscopia/efeitos adversos , Laparoscopia/instrumentação , Temperatura
14.
Surg Endosc ; 35(6): 2981-2985, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-32591940

RESUMO

INTRODUCTION: Stray energy transfer from surgical monopolar radiofrequency energy instruments can cause unintended thermal injuries during laparoscopic surgery. Single-incision laparoscopic surgery transfers more stray energy than traditional laparoscopic surgery. There is paucity of published data concerning stray energy during single-incision robotic surgery. The purpose of this study was to quantify stray energy transfer during traditional, multiport robotic surgery (TRS) compared to single-incision robotic surgery (SIRS). METHODS: An in vivo porcine model was used to simulate a multiport or single-incision robotic cholecystectomy (DaVinci Si, Intuitive Surgical, Sunnyvale, CA). A 5 s, open air activation of the monopolar scissors was done on 30 W and 60 W coag mode (ForceTriad, Covidien-Medtronic, Boulder, CO) and Swift Coag effect 3, max power 180 W (VIO 300D, ERBE USA, Marietta, GA). Temperature of the tissue (°C) adjacent to the tip of the assistant grasper or the camera was measured with a thermal camera (E95, FLIR Systems, Wilsonville, OR) to quantify stray energy transfer. RESULTS: Stray energy transfer was greater in the SIRS setup compared to TRS setup at the assistant grasper (11.6 ± 3.3 °C vs. 8.4 ± 1.6 °C, p = 0.013). Reducing power from 60 to 30 W significantly reduced stray energy transfer in SIRS (15.3 ± 3.4 °C vs. 11.6 ± 3.3 °C, p = 0.023), but not significantly for TRS (9.4 ± 2.5 °C vs. 8.4 ± 1.6 °C, p = 0.278). The use of a constant voltage regulating generator also minimized stray energy transfer for both SIRS (0.7 ± 0.4 °C, p < 0.001) and TRS (0.7 ± 0.4 °C, p < 0.001). CONCLUSIONS: More stray energy transfer occurs during single-incision robotic surgery than multiport robotic surgery. Utilizing a constant voltage regulating generator minimized stray energy transfer for both setups. These data can be used to guide robotic surgeons in their use of safe, surgical energy.


Assuntos
Laparoscopia , Procedimentos Cirúrgicos Robóticos , Robótica , Ferida Cirúrgica , Animais , Transferência de Energia , Suínos
15.
Appetite ; 164: 105277, 2021 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-33984401

RESUMO

Reducing meat consumption may improve human health, curb environmental damage, and limit the large-scale suffering of animals raised in factory farms. Most attention to reducing consumption has focused on restructuring environments where foods are chosen or on making health or environmental appeals. However, psychological theory suggests that interventions appealing to animal welfare concerns might operate on distinct, potent pathways. We conducted a systematic review and meta-analysis evaluating the effectiveness of these interventions. We searched eight academic databases and extensively searched grey literature. We meta-analyzed 100 studies assessing interventions designed to reduce meat consumption or purchase by mentioning or portraying farm animals, that measured behavioral or self-reported outcomes related to meat consumption, purchase, or related intentions, and that had a control condition. The interventions consistently reduced meat consumption, purchase, or related intentions at least in the short term with meaningfully large effects (meta-analytic mean risk ratio [RR] = 1.22; 95% CI: [1.13, 1.33]). We estimated that a large majority of population effect sizes (71%; 95% CI: [59%, 80%]) were stronger than RR = 1.1 and that few were in the unintended direction. Via meta-regression, we identified some specific characteristics of studies and interventions that were associated with effect size. Risk-of-bias assessments identified both methodological strengths and limitations of this literature; however, results did not differ meaningfully in sensitivity analyses retaining only studies at the lowest risk of bias. Evidence of publication bias was not apparent. In conclusion, animal welfare interventions preliminarily appear effective in these typically short-term studies of primarily self-reported outcomes. Future research should use direct behavioral outcomes that minimize the potential for social desirability bias and are measured over long-term follow-up.


Assuntos
Comportamento do Consumidor , Carne , Bem-Estar do Animal , Animais , Humanos , Teoria Psicológica
16.
Surg Endosc ; 34(4): 1863-1867, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31222632

RESUMO

INTRODUCTION: Surgical fires are a rare event that still occur at a significant rate and can result in severe injury and death. Surgical fires are fueled by vapor from alcohol-based skin preparations in the presence of increased oxygen concentration and a spark from an energy device. Carbon dioxide (CO2) is used to extinguish electrical fires, and we sought to evaluate its effect on fire creation in the operating room. We hypothesize that CO2 delivered by the energy device will decrease the frequency of surgical fires fueled by alcohol-based skin preparations. METHODS: An ex vivo model with 15 × 15 cm section of clipped, porcine skin was used. A commercially available electrosurgical pencil with a smoke evacuation tip was connected to a laparoscopic CO2 insufflation system. The electrosurgical pencil was activated for 2 s at 30 watts coagulation mode immediately after application of alcohol-based surgical skin preparations: 70% isopropyl alcohol with 2% chlorhexidine gluconate (CHG-IPA) or 74% isopropyl alcohol with 0.7% iodine povacrylex (Iodine-IPA). CO2 was infused via the smoke evacuation pencil at flow rates from 0 to 8 L/min. The presence of a flame was determined visually and confirmed with a thermal camera (FLIR Systems, Boston, MA). RESULTS: Carbon dioxide eliminated fire formation at a flow rate of 1 L/min with CHG-IPA skin prep (0% vs. 60% with no CO2, p < 0.0001). Carbon dioxide reduced fire formation at 1 L/min (25% vs. 47% with no CO2, p = 0.1) with Iodine-IPA skin prep and fires were eliminated at 2 L/min of flow with Iodine-IPA skin prep (p < 0.0001). CONCLUSION: Carbon dioxide can eliminate surgical fires caused by energy devices in the presence of alcohol-based skin preps. Future studies should determine the optimal technique and flow rate of carbon dioxide in these settings.


Assuntos
Dióxido de Carbono/administração & dosagem , Procedimentos Cirúrgicos Dermatológicos , Incêndios , Salas Cirúrgicas , 2-Propanol/administração & dosagem , Animais , Clorexidina/administração & dosagem , Clorexidina/análogos & derivados , Humanos , Suínos
17.
J Adolesc Res ; 35(1): 16-50, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32161431

RESUMO

AIMS: This study describes when and how adolescents engage with their fast-moving and dynamic digital environment as they go about their daily lives. We illustrate a new approach - screenomics - for capturing, visualizing, and analyzing screenomes, the record of individuals' day-to-day digital experiences. SAMPLE: Over 500,000 smartphone screenshots provided by four Latino/Hispanic youth, age 14-15 years, from low-income, racial/ethnic minority neighborhoods. METHOD: Screenomes collected from smartphones for one to three months, as sequences of smartphone screenshots obtained every five seconds that the device is activated, are analyzed using computational machinery for processing images and text, machine learning algorithms, human-labeling, and qualitative inquiry. FINDINGS: Adolescents' digital lives differ substantially across persons, days, hours, and minutes. Screenomes highlight the extent of switching among multiple applications, and how each adolescent is exposed to different content at different times for different durations - with apps, food-related content, and sentiment as illustrative examples. IMPLICATIONS: We propose that the screenome provides the fine granularity of data needed to study individuals' digital lives, for testing existing theories about media use, and for generation of new theory about the interplay between digital media and development.

18.
Ann Surg ; 270(4): 675-680, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31348044

RESUMO

OBJECTIVE: To determine the impact of radiofrequency (RF) and microwave (MW) energy compared to direct cautery on metatstatic colon cancer growth. BACKGROUND: Hepatic ablation with MW and RF energy creates a temperature gradient around a target site with temperatures known to create tissue injury and cell death. In contrast, direct heat application (cautery) vaporizes tissue with a higher site temperature but reduced heat gradient on surrounding tissue. We hypothesize that different energy devices create variable zones of sublethal injury that may promote tumor recurrence. To test this hypothesis we applied MW, RF, and cautery to normal murine liver with a concomitant metastatic colon cancer challenge. METHODS: C57/Bl6 mice received hepatic thermal injury with MW, RF, or cautery to create a superficial 3-mm lesion immediately after intrasplenic injection of 50K MC38 colon cancer cells. Thermal imaging recorded tissue temperature during ablation and for 10 seconds after energy cessation. Hepatic tumor location and volume was determined at day 7. RESULTS: Cautery demonstrated the highest maximum tissue temperatures (129°C) with more rapid return to baseline compared to MW or RF energy. All mice had metastasis at the ablation site. Mean tumor volume was significantly greater in the MW (95.3 mm; P = 0.007) and RF (55.7 mm; P = 0.015) than cautery (7.13 mm). There was no difference in volume between MW and RF energy (P = 0.2). CONCLUSIONS: Hepatic thermal ablation promotes colon cancer metastasis at the injury site. MV and RF energy result in greater metastatic volume than cautery. These data suggest that the method of energy delivery promotes local metastasis.


Assuntos
Neoplasias do Colo/patologia , Neoplasias Hepáticas/secundário , Neoplasias Hepáticas/cirurgia , Micro-Ondas/uso terapêutico , Recidiva Local de Neoplasia/prevenção & controle , Ablação por Radiofrequência , Animais , Feminino , Hipertermia Induzida , Imunocompetência , Neoplasias Hepáticas/imunologia , Neoplasias Hepáticas/patologia , Camundongos , Camundongos Endogâmicos C57BL , Recidiva Local de Neoplasia/patologia , Resultado do Tratamento
19.
Anesthesiology ; 130(3): 492-501, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30664060

RESUMO

Operating room fires are rare but devastating events. Guidelines are available for the prevention and management of surgical fires; however, these recommendations are based on expert opinion and case series. The three components of an operating room fire are present in virtually all surgical procedures: an oxidizer (oxygen, nitrous oxide), an ignition source (i.e., laser, "Bovie"), and a fuel. This review analyzes each fire ingredient to determine the optimal clinical strategy to reduce the risk of fire. Surgical checklists, team training, and the specific management of an operating room fire are also reviewed.


Assuntos
Incêndios/prevenção & controle , Salas Cirúrgicas/métodos , Salas Cirúrgicas/normas , Oxigênio/efeitos adversos , Eletrocoagulação/efeitos adversos , Depuradores de Gases/tendências , Humanos , Oxigênio/administração & dosagem , Procedimentos de Cirurgia Plástica/efeitos adversos
20.
J Surg Res ; 244: 368-373, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31323392

RESUMO

BACKGROUND: Emerging wearable technology has the potential to quantify both preoperative and postoperative patient activity. The purpose of this study was to characterize postoperative recovery trajectories for 1 mo after common surgical procedures. MATERIALS AND METHODS: Patients included were scheduled for common elective operations. A wearable activity device was worn for at least 3 d preoperatively and 28 d postoperatively. Postoperative steps per day were compared with preoperative baseline steps, with recovery trajectories reported as a percentage of patients' baseline values. Recovery trajectories were compared between groups based on admission type and operation type. RESULTS: Two hundred ten patients were enrolled, and 143 patients (68%) completed follow-up. Patients took a median 5342 steps per day preoperatively and had significantly decreased steps on the first postoperative day, including those undergoing inguinal hernia repair (22% of baseline steps, P < 0.001). Four weeks postoperatively, steps per day had not returned to baseline in patients undergoing minimally invasive abdominal (88% of baseline, P = 0.035), open abdominal (64% of baseline, P = 0.002), and thoracic (32% of baseline, P = 0.002) operations. All groups of patients showed a rapid recovery of steps during the first postoperative week, followed by a slower return to baseline. Recovery trajectories differed based on both admission type and operation type. CONCLUSIONS: Wearable activity monitors provide useful technology for quantification of postoperative activity recovery trajectories of steps per day in comparison to preoperative activity levels, with internal validity differentiating recovery trajectories grouping by broad categorization of operation type and by admission type. Activity recovery is a patient-centered outcome that can be used for counseling as well as for intervening to improve activity levels after surgery.


Assuntos
Recuperação de Função Fisiológica , Procedimentos Cirúrgicos Operatórios , Dispositivos Eletrônicos Vestíveis , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Período Pós-Operatório
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa