Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Clin Chem Lab Med ; 61(9): 1580-1589, 2023 08 28.
Artigo em Inglês | MEDLINE | ID: mdl-37083158

RESUMO

OBJECTIVES: Alzheimer's disease (AD) is considered the most common cause of dementia in older people. Recently, blood-based markers (BBM) Aß1-42, Aß1-40, and phospho Tau181 (p-Tau181) have demonstrated the potential to transform the diagnosis and prognostic assessment of AD. Our aim was to investigate the effect of different storage conditions on the quantification of these BBM and to evaluate the interchangeability of plasma and serum samples. METHODS: Forty-two individuals with some degree of cognitive impairment were studied. Thirty further patients were retrospectively selected. Aß1-42, Aß1-40, and p-Tau181 were quantified using the LUMIPULSE-G600II automated platform. To assess interchangeability between conditions, correction factors for magnitudes that showed strong correlations were calculated, followed by classification consistency studies. RESULTS: Storing samples at 4 °C for 8-9 days was associated with a decrease in Aß fractions but not when stored for 1-2 days. Using the ratio partially attenuated the pre-analytical effects. For p-Tau181, samples stored at 4 °C presented lower concentrations, whereas frozen samples presented higher ones. Concerning classification consistency in comparisons that revealed strong correlations (p-Tau181), the percentage of total agreement was greater than 90 % in a large number of the tested cut-offs values. CONCLUSIONS: Our findings provide relevant information for the standardization of sample collection and storage in the analysis of AD BBM in an automated platform. This knowledge is crucial to ensure their introduction into clinical settings.


Assuntos
Doença de Alzheimer , Humanos , Idoso , Doença de Alzheimer/diagnóstico , Proteínas tau , Peptídeos beta-Amiloides , Estudos Retrospectivos , Biomarcadores
2.
Alzheimers Res Ther ; 16(1): 139, 2024 06 26.
Artigo em Inglês | MEDLINE | ID: mdl-38926773

RESUMO

BACKGROUND: Recently developed blood markers for Alzheimer's disease (AD) detection have high accuracy but usually require ultra-sensitive analytic tools not commonly available in clinical laboratories, and their performance in clinical practice is unknown. METHODS: We analyzed plasma samples from 290 consecutive participants that underwent lumbar puncture in routine clinical practice in a specialized memory clinic (66 cognitively unimpaired, 130 participants with mild cognitive impairment, and 94 with dementia). Participants were classified as amyloid positive (A +) or negative (A-) according to CSF Aß1-42/Aß1-40 ratio. Plasma pTau217, pTau181, Aß1-42 and Aß1-40 were measured in the fully-automated LUMIPULSE platform. We used linear regression to compare plasma biomarkers concentrations between A + and A- groups, evaluated Spearman's correlation between plasma and CSF and performed ROC analyses to assess their diagnostic accuracy to detect brain amyloidosis as determined by CSF Aß1-42/Aß1-40 ratio. We analyzed the concordance of pTau217 with CSF amyloidosis. RESULTS: Plasma pTau217 and pTau181 concentration were higher in A + than A- while the plasma Aß1-42/Aß1-40 ratio was lower in A + compared to A-. pTau181 and the Aß1-42/Aß1-40 ratio showed moderate correlation between plasma and CSF (Rho = 0.66 and 0.69, respectively). The areas under the ROC curve to discriminate A + from A- participants were 0.94 (95% CI 0.92-0.97) for pTau217, and 0.88 (95% CI 0.84-0.92) for both pTau181 and Aß1-42/Aß1-40. Chronic kidney disease (CKD) was related to increased plasma biomarker concentrations, but ratios were less affected. Plasma pTau217 had the highest fold change (× 3.2) and showed high predictive capability in discriminating A + from A-, having 4-7% misclassification rate. The global accuracy of plasma pTau217 using a two-threshold approach was robust in symptomatic groups, exceeding 90%. CONCLUSION: The evaluation of blood biomarkers on an automated platform exhibited high diagnostic accuracy for AD pathophysiology, and pTau217 showed excellent diagnostic accuracy to identify participants with AD in a consecutive sample representing the routine clinical practice in a specialized memory unit.


Assuntos
Doença de Alzheimer , Peptídeos beta-Amiloides , Biomarcadores , Fragmentos de Peptídeos , Proteínas tau , Humanos , Peptídeos beta-Amiloides/sangue , Peptídeos beta-Amiloides/líquido cefalorraquidiano , Doença de Alzheimer/sangue , Doença de Alzheimer/diagnóstico , Doença de Alzheimer/líquido cefalorraquidiano , Feminino , Masculino , Fragmentos de Peptídeos/sangue , Fragmentos de Peptídeos/líquido cefalorraquidiano , Proteínas tau/sangue , Proteínas tau/líquido cefalorraquidiano , Idoso , Biomarcadores/sangue , Biomarcadores/líquido cefalorraquidiano , Pessoa de Meia-Idade , Disfunção Cognitiva/diagnóstico , Disfunção Cognitiva/sangue , Disfunção Cognitiva/líquido cefalorraquidiano , Idoso de 80 Anos ou mais , Curva ROC , Fosforilação
3.
Neurology ; 103(4): e209676, 2024 Aug 27.
Artigo em Inglês | MEDLINE | ID: mdl-39074338

RESUMO

BACKGROUND AND OBJECTIVES: Cerebral hemorrhages are an exclusion criterion and potential adverse effect of antiamyloid agents. It is, therefore, critical to characterize the natural history of cerebral microbleeds in populations genetically predisposed to Alzheimer disease (AD), such as Down syndrome (DS). We aimed to assess microbleed emergence in adults with DS across the AD spectrum, defining their topography and associations with clinical variables, cognitive outcomes, and fluid and neuroimaging biomarkers. METHODS: This cross-sectional study included participants aged 18 years or older from the Down-Alzheimer Barcelona Neuroimaging Initiative and Sant Pau Initiative on Neurodegeneration with T1-weighted and susceptibility-weighted images. Participants underwent comprehensive assessments, including apolipoprotein E (APOE) genotyping; fluid and plasma determinations of beta-amyloid, tau, and neurofilament light; cognitive outcomes (Cambridge Cognitive Examination and modified Cued Recall Test); and vascular risk factors (hypertension, diabetes mellitus, and dyslipidemia). We manually segmented microbleeds and characterized their topography. Associations between microbleed severity and AD biomarkers were explored using between-group comparisons (none vs 1 vs 2+) and multivariate linear models. RESULTS: We included 276 individuals with DS and 158 healthy euploid controls (mean age = 47.8 years, 50.92% female). Individuals with DS were more likely to have microbleeds than controls (20% vs 8.9%, p < 0.001), with more severe presentation (12% with 2+ vs 1.9%). Microbleeds increased with age (12% 20-30 years vs 60% > 60 years) and AD clinical stage (12.42% asymptomatic, 27.9% prodromal, 35.09% dementia) were more common in APOEε4 carriers (26% vs 18.3% noncarriers, p = 0.008), but not associated with vascular risk factors (p > 0.05). Microbleeds were predominantly posterior (cerebellum 33.66%; occipital 14.85%; temporal 21.29%) in participants with DS. Associations with microbleed severity were found for neuroimaging and fluid AD biomarkers, but only hippocampal volumes (standardized ß = -0.18 [-0.31, -0.06], p < 0.005) and CSF p-tau-181 concentrations (ß = 0.26 [0.12, 0.41], p < 0.005) survived regression controlling for age and disease stage, respectively. Microbleeds had limited effect on cognitive outcomes. DISCUSSION: In participants with DS, microbleeds present with a posterior, lobar predominance, are associated with disease severity, but do not affect cognitive performance. These results suggest an interplay between AD pathology and vascular lesions, implicating microbleeds as a risk factor limiting the use of antiamyloid agents in this population.


Assuntos
Doença de Alzheimer , Peptídeos beta-Amiloides , Biomarcadores , Hemorragia Cerebral , Síndrome de Down , Proteínas tau , Humanos , Síndrome de Down/líquido cefalorraquidiano , Síndrome de Down/complicações , Síndrome de Down/diagnóstico por imagem , Feminino , Masculino , Pessoa de Meia-Idade , Estudos Transversais , Biomarcadores/líquido cefalorraquidiano , Biomarcadores/sangue , Hemorragia Cerebral/diagnóstico por imagem , Hemorragia Cerebral/líquido cefalorraquidiano , Doença de Alzheimer/líquido cefalorraquidiano , Doença de Alzheimer/diagnóstico por imagem , Peptídeos beta-Amiloides/líquido cefalorraquidiano , Proteínas tau/líquido cefalorraquidiano , Adulto , Imageamento por Ressonância Magnética , Idoso , Apolipoproteínas E/genética , Proteínas de Neurofilamentos/líquido cefalorraquidiano , Proteínas de Neurofilamentos/sangue
4.
Res Sq ; 2023 Dec 13.
Artigo em Inglês | MEDLINE | ID: mdl-38168408

RESUMO

BACKGROUND: Recently developed blood markers for Alzheimer's disease (AD) detection have high accuracy but usually require ultra-sensitive analytic tools not commonly available in clinical laboratories, and their performance in clinical practice is unknown. METHODS: We analyzed plasma samples from 290 consecutive participants that underwent lumbar puncture in routine clinical practice in a specialized memory clinic (66 cognitively unimpaired, 130 participants with mild cognitive impairment, and 94 with dementia). Participants were classified as amyloid positive (A+) or negative (A-) according to CSF Aß1-42/Aß1-40 ratio. Plasma pTau217, pTau181, Aß1-42 and Aß1-40 were measured in the fully-automated LUMIPULSE platform. We used linear regression to compare plasma biomarkers concentrations between A + and A- groups, evaluated Spearman's correlation between plasma and CSF and performed ROC analyses to assess their diagnostic accuracy to detect brain amyloidosis as determined by CSF Aß1-42/Aß1-40 ratio. We analyzed the potential of pTau217 to predict amyloidosis in CSF. RESULTS: Plasma pTau217 and pTau181 concentration were higher in A + than A- while the plasma Aß1-42/Aß1-40 ratio was lower in A + compared to A-. pTau181 and the Aß1-42/Aß1-40 ratio showed moderate correlation between plasma and CSF (Rho = 0.66 and 0.69, respectively). The areas under the ROC curve to discriminate A + from A- participants were 0.94 (95% CI 0.92-0.97) for pTau217, and 0.88 (95% CI 0.84-0.92) for both pTau181 and Aß1-42/Aß1-40. Chronic kidney disease (CKD) was related to increased plasma biomarker concentrations, but ratios were less affected. Plasma pTau217 had the highest fold change (x4.2) and showed high predictive capability in discriminating A + from A-, having 4-7% misclassification rate. The global accuracy of plasma pTau217 using a two-threshold approach was robust in symptomatic groups, exceeding 90%. CONCLUSION: The evaluation of blood biomarkers on an automated platform exhibited high diagnostic accuracy for AD pathophysiology, and pTau217 showed excellent diagnostic accuracy to identify participants with AD in a consecutive sample representing the routine clinical practice in a specialized memory unit.

5.
Med Clin (Barc) ; 159(7): 313-320, 2022 10 14.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-35042605

RESUMO

INTRODUCTION: Mechanical thrombectomy (MT) has meant a change in natural history of acute ischemic stroke. Our aim is to assess the possible association between different factors and prognosis in patients treated with MT in a third degree Spanish hospital. METHODS: Cross-sectional study including 198 patients underwent MT because of acute ischemic stroke between 2012 and 2020. Sociodemographic, vascular risk factors (VRF) and clinical-radiologic factors were recorded. Functional outcome was evaluated based on modified Rankin Scale (mRS) at 90 days, being mRS≤2 favorable and mRS≥3 unfavorable outcome. RESULTS: Mean age 67.7±13.5 years, 50.5% women. Arterial hypertension was the most prevalent VRF (65.7%). National Institute of Health Stroke Scale (NIHSS) median value at admission was 17.0 (8.0; 22.0). 40.9% of cases also received fibrinolytic treatment. Conscious sedation was performed in 66.7% patients. Median passes of MT were 2, and median duration 41min. Successful recanalization was achieved in 79.9% and mRS≤2 at 90 days was registered at 59.5% cases. Age, type 2 diabetes (T2D), number of MT passes and procedure duration were associated with mRS≥3. Successful recanalization was associated with mRS≤2. Regression model confirmed these associations in age (OR: 1.56CI%: 1.11; 2.20); T2D (OR: 3.51CI%: 1.38; 8.97) and successful recanalization (OR: 0.07CI%: 0.02; 0.28). CONCLUSION: Age, T2D and failed recanalization increase risk for unfavorable outcome at 90 days in patients with AIS treated with MT. Procedure time duration should be considered as a possible determinant factor in functional outcome.


Assuntos
Isquemia Encefálica , Diabetes Mellitus Tipo 2 , AVC Isquêmico , Acidente Vascular Cerebral , Idoso , Idoso de 80 Anos ou mais , Pré-Escolar , Estudos Transversais , Diabetes Mellitus Tipo 2/complicações , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Retrospectivos , Stents/efeitos adversos , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/terapia , Trombectomia/efeitos adversos , Trombectomia/métodos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa