Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
JACC Cardiovasc Interv ; 14(2): 198-207, 2021 01 25.
Artigo em Inglês | MEDLINE | ID: mdl-33478637

RESUMO

OBJECTIVES: This study sought to evaluate the incidence and causes of percutaneous coronary intervention (PCI) at different time periods following transcatheter aortic valve replacement (TAVR). BACKGROUND: Coronary artery disease (CAD) and aortic stenosis frequently coexist, but the optimal management of CAD following TAVR remains incompletely elucidated. METHODS: Patients undergoing unplanned PCI after TAVR were retrospectively included in an international multicenter registry. RESULTS: Between July 2008 and March 2019, a total of 133 patients (0.9%; from a total cohort of 15,325) underwent unplanned PCI after TAVR (36.1% after balloon-expandable bioprosthesis, 63.9% after self-expandable bioprosthesis). The median time to PCI was 191 days (interquartile range: 59 to 480 days). The daily incidence of PCI was highest during the first week after TAVR and then declined over time. Overall, the majority of patients underwent PCI due to an acute coronary syndrome, and specifically 32.3% had non-ST-segment elevation myocardial infarction, 15.4% had unstable angina, 9.8% had ST-segment elevation myocardial infarction, and 2.2% had cardiac arrest. However, chronic coronary syndromes are the main indication beyond 2 years. PCI success was reported in almost all cases (96.6%), with no significant differences between patients treated with balloon-expandable and self-expandable bioprostheses (100% vs. 94.9%; p = 0.150). CONCLUSIONS: Unplanned PCI after TAVR is rare, with an incidence declining over time after TAVR. The main indication to PCI is acute coronary syndrome in the first 2 years after TAVR, and thereafter chronic coronary syndromes become prevalent. Unplanned PCIs are frequently successfully performed after TAVR, with no apparent differences between balloon-expandable and self-expandable bioprostheses. (Revascularization After Transcatheter Aortic Valve Implantation [REVIVAL]; NCT03283501).


Assuntos
Estenose da Valva Aórtica , Intervenção Coronária Percutânea , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Humanos , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa