Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Ann Hepatol ; 19(1): 31-35, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31587985

RESUMO

INTRODUCTION AND OBJECTIVES: We aimed to study the liver iron concentration in patients referred for hyperferritinemia to six hospitals in the Basque Country and to determine if there were differences between patients with or without metabolic syndrome. PATIENTS AND METHODS: Metabolic syndrome was defined by accepted criteria. Liver iron concentration was determined by magnetic resonance imaging. RESULTS: We obtained the data needed to diagnose metabolic syndrome in 276 patients; a total of 135 patients (49%), 115/240 men (48%), and 20/36 women (55.6%) presented metabolic syndrome. In all 276 patients, an MRI for the determination of liver iron concentration (mean±SD) was performed. The mean liver iron concentration was 30.83±19.38 for women with metabolic syndrome, 38.84±25.50 for men with metabolic syndrome, and 37.66±24.79 (CI 95%; 33.44-41.88) for the whole metabolic syndrome group. In 141 patients (51%), metabolic syndrome was not diagnosed: 125/240 were men (52%) and 16/36 were women (44.4%). The mean liver iron concentration was 34.88±16.18 for women without metabolic syndrome, 44.48±38.16 for men without metabolic syndrome, and 43.39±36.43 (CI 95%, 37.32-49.46) for the whole non-metabolic syndrome group. Comparison of the mean liver iron concentration from both groups (metabolic syndrome vs non-metabolic syndrome) revealed no significant differences (p=0.12). CONCLUSIONS: Patients with hyperferritinemia and metabolic syndrome presented a mildly increased mean liver iron concentration that was not significantly different to that of patients with hyperferritinemia and non-metabolic syndrome.


Assuntos
Hiperferritinemia/diagnóstico por imagem , Sobrecarga de Ferro/diagnóstico por imagem , Ferro/metabolismo , Fígado/diagnóstico por imagem , Síndrome Metabólica/metabolismo , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Casos e Controles , Estudos de Coortes , Feminino , Humanos , Hiperferritinemia/complicações , Hiperferritinemia/metabolismo , Sobrecarga de Ferro/complicações , Sobrecarga de Ferro/metabolismo , Fígado/metabolismo , Imageamento por Ressonância Magnética , Masculino , Síndrome Metabólica/complicações , Pessoa de Meia-Idade , Estudos Prospectivos , Adulto Jovem
2.
Ann Hepatol ; 15(4): 540-544, 2016 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-28869748

RESUMO

Background & aims. Hyperferritinemia (HF) is frequently present in patients with metabolic syndrome (MS). MS associated with HF is named dysmetabolic hyperferritinemia (DH). There are some publications that propose that DH is associated with a raised liveriron concentration (LIC). We studied the LIC in patients referred for HF to a secondary hospital to determine if there are differences between patients with or without MS. MATERIAL AND METHODS: We conducted a prospective study of 132 consecutive patients with HF from January to December 2010. The MS was defined by the International Diabetes Federation criteria (2005). LIC was determined by Magnetic resonance imaging (MRI). RESULTS: The number of patients for which there was enough data to determine MS was 97, out of which 54 had MS and 43 had no MS (NMS). In 54/97 patients, MRI for LIC determination was performed. From the MS group, 44 were men (27 underwent MRI) and 10 women (9 MRI). The mean LIC was 27.83 ± 20.90 ?mol/g for the MS group. In the NMS group, 36 were men (13 MRI), and 7 women (5 MRI). In 18 patients from the NMS group, LIC was determined by MRI. The mean LIC was 33.16 ± 19.61 ?mol/g in the NMS group. We compared the mean values of LIC from both groups (MS vs. NMS) and no significant differences were found (p = 0.067). CONCLUSION: Patients with DH present a mean LIC within normal values and their values do not differ from those of patients with HF but without MS.


Assuntos
Ferritinas/sangue , Distúrbios do Metabolismo do Ferro/metabolismo , Ferro/metabolismo , Fígado/metabolismo , Síndrome Metabólica/metabolismo , Adulto , Idoso , Biomarcadores/sangue , Feminino , Humanos , Distúrbios do Metabolismo do Ferro/sangue , Distúrbios do Metabolismo do Ferro/diagnóstico por imagem , Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética , Masculino , Síndrome Metabólica/sangue , Síndrome Metabólica/diagnóstico por imagem , Pessoa de Meia-Idade , Estudos Prospectivos , Espanha , Regulação para Cima
3.
Arch Med Sci ; 19(3): 784-791, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37313200

RESUMO

Determination of liver iron concentration by magnetic resonance imaging (MRI) is becoming the new technique of choice for the diagnosis of iron overload in hereditary haemochromatosis and other liver iron surcharge diseases. Determination of hepatic iron concentration obtained by liver biopsy has been the gold standard for years. The development of MRI techniques, via signal intensity ratio methods or relaxometry, has provided a non-invasive and more accurate approach to the diagnosis of liver iron overload. This article reviews the available MRI methods for the determination of liver iron concentration and also evaluates the technique for the diagnosis and quantification of iron overload in different clinical practice scenarios.

4.
Biomed Res Int ; 2015: 294024, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25874207

RESUMO

PURPOSE: The objectives were (i) construction of a phantom to reproduce the behavior of iron overload in the liver by MRI and (ii) assessment of the variability of a previously validated method to quantify liver iron concentration between different MRI devices using the phantom and patients. MATERIALS AND METHODS: A phantom reproducing the liver/muscle ratios of two patients with intermediate and high iron overload. Nine patients with different levels of iron overload were studied in 4 multivendor devices and 8 of them were studied twice in the machine where the model was developed. The phantom was analysed in the same equipment and 14 times in the reference machine. RESULTS: FeCl3 solutions containing 0.3, 0.5, 0.6, and 1.2 mg Fe/mL were chosen to generate the phantom. The average of the intramachine variability for patients was 10% and for the intermachines 8%. For the phantom the intramachine coefficient of variation was always below 0.1 and the average of intermachine variability was 10% for moderate and 5% for high iron overload. CONCLUSION: The phantom reproduces the behavior of patients with moderate or high iron overload. The proposed method of calculating liver iron concentration is reproducible in several different 1.5 T systems.


Assuntos
Ferro/metabolismo , Fígado/diagnóstico por imagem , Fígado/metabolismo , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Humanos , Radiografia , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa