Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Eur Heart J ; 43(13): 1320-1330, 2022 03 31.
Artigo em Inglês | MEDLINE | ID: mdl-34735004

RESUMO

AIM: Patients with diabetes mellitus are at high risk of adverse events after percutaneous revascularization, with no differences in outcomes between most contemporary drug-eluting stents. The Cre8 EVO stent releases a formulation of sirolimus with an amphiphilic carrier from laser-dug wells, and has shown clinical benefits in diabetes. We aimed to compare Cre8 EVO stents to Resolute Onyx stents (a contemporary polymer-based zotarolimus-eluting stent) in patients with diabetes. METHODS AND RESULTS: We did an investigator-initiated, randomized, controlled, assessor-blinded trial at 23 sites in Spain. Eligible patients had diabetes and required percutaneous coronary intervention. A total of 1175 patients were randomly assigned (1:1) to receive Cre8 EVO or Resolute Onyx stents. The primary endpoint was target-lesion failure, defined as a composite of cardiac death, target-vessel myocardial infarction, and clinically indicated target-lesion revascularization at 1-year follow-up. The trial had a non-inferiority design with a 4% margin for the primary endpoint. A superiority analysis was planned if non-inferiority was confirmed. There were 106 primary events, 42 (7.2%) in the Cre8 EVO group and 64 (10.9%) in the Resolute Onyx group [hazard ratio (HR): 0.65, 95% confidence interval (CI): 0.44-0.96; Pnon-inferiority < 0.001; Psuperiority = 0.030]. Among the secondary endpoints, Cre8 EVO stents had significantly lower rate than Resolute Onyx stents of target-vessel failure (7.5% vs. 11.1%, HR: 0.67, 95% CI: 0.46-0.99; P = 0.042). Probable or definite stent thrombosis and all-cause death were not significantly different between groups. CONCLUSION: In patients with diabetes, Cre8 EVO stents were non-inferior to Resolute Onyx stents with regard to target-lesion failure composite outcome. An exploratory analysis for superiority at 1 year suggests that the Cre8 EVO stents might be superior to Resolute Onyx stents with regard to the same outcome. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov: NCT03321032.


Assuntos
Doença da Artéria Coronariana , Diabetes Mellitus , Stents Farmacológicos , Intervenção Coronária Percutânea , Doença da Artéria Coronariana/etiologia , Doença da Artéria Coronariana/terapia , Humanos , Intervenção Coronária Percutânea/métodos , Desenho de Prótese , Sirolimo/análogos & derivados , Sirolimo/uso terapêutico , Resultado do Tratamento
2.
BMC Cardiovasc Disord ; 17(1): 54, 2017 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-28173757

RESUMO

BACKGROUND: The AMI code is a regional network enhancing a rapid and widespread access to reperfusion therapy (giving priority to primary angioplasty) in patients with acute ST-segment elevation myocardial infarction (STEMI). We aimed to assess the long-term control of conventional cardiovascular risk factors after a STEMI among patients included in the AMI code registry. DESIGN AND METHODS: Four hundred and fifty-four patients were prospectively included between June-2009 and April-2013. Clinical characteristics were collected at baseline. The long-term control of cardiovascular risk factors and cardiovascular morbidity/mortality was assessed among the 6-months survivors. RESULTS: A total of 423 patients overcame the first 6 months after the STEMI episode, of whom 370 (87%) underwent reperfusion therapy (363, 98% of them, with primary angioplasty). At 1-year follow-up, only 263 (62%) had adequate blood pressure control, 123 (29%) had LDL-cholesterol within targeted levels, 126/210 (60%) smokers had withdrawn from their habit and 40/112 (36%) diabetic patients had adequate glycosylated hemoglobin levels. During a median follow-up of 20 (11-30) months, cumulative mortality of 6 month-survivors was 6.1%, with 9.9% of hospital cardiovascular readmissions. The lack of assessment of LDL and HDL-cholesterol were significantly associated with higher mortality and cardiovascular readmission rates. CONCLUSIONS: Whereas implementation of the AMI code resulted in a widespread access to rapid reperfusion therapy, its long-term therapeutic benefit may be partially counterbalanced by a manifestly suboptimal control of cardiovascular risk factors. Further efforts should be devoted to secondary prevention strategies after STEMI.


Assuntos
Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Prevenção Secundária/métodos , Idoso , Idoso de 80 Anos ou mais , Anti-Hipertensivos/uso terapêutico , Prestação Integrada de Cuidados de Saúde , Feminino , Humanos , Hipoglicemiantes/uso terapêutico , Hipolipemiantes/uso terapêutico , Masculino , Pessoa de Meia-Idade , Readmissão do Paciente , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Avaliação de Programas e Projetos de Saúde , Estudos Prospectivos , Recidiva , Sistema de Registros , Medição de Risco , Fatores de Risco , Comportamento de Redução do Risco , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico , Infarto do Miocárdio com Supradesnível do Segmento ST/mortalidade , Infarto do Miocárdio com Supradesnível do Segmento ST/fisiopatologia , Fumar/efeitos adversos , Abandono do Hábito de Fumar , Prevenção do Hábito de Fumar , Fatores de Tempo , Resultado do Tratamento
3.
Rev Esp Cardiol (Engl Ed) ; 77(2): 150-157, 2024 Feb.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-37879431

RESUMO

INTRODUCTION AND OBJECTIVES: The optimal antithrombotic strategy following left atrial appendage closure (LAAC) is poorly defined in patients with nonvalvular atrial fibrillation. We assessed the safety and effectiveness of a single antiplatelet treatment (SAPT) strategy after LAAC in a population at high risk of ischemic and bleeding events. METHODS: This single-center, observational, prospective study included a consecutive cohort of patients who underwent LAAC using the LAmbre device (Lifetech Scientific, China) and who were discharged with SAPT. The primary outcome was a composite of stroke, systemic embolism, and device-related thrombosis during follow-up. Secondary endpoints were cardiovascular mortality and major bleeding events (BARC ≥3a). Clinical follow-up was performed at 1, 6, and 12 months and subsequently on an annual basis. Transesophageal echocardiography was performed at 1 and 12 months of follow-up. RESULTS: The study comprised 74 patients. The median age was 77 [72-83] years and 43% were women. The cohort exhibited a high prevalence of comorbidities and cardiovascular risk factors. The median CHA2DS2-VASc and HAS-BLED scores were 4 [3-6] and 4 [4-5], respectively. The median length of follow-up was 2.5 years (188 patients-year). During follow-up, device-related thrombosis occurred in 3 patients (4%). Ischemic stroke occurred in 1 patient (1.3%, rate 0.5%/y), representing a 90.9% relative risk reduction compared with the risk predicted by CHA2DS2-VASc. Major bleeding events occurred in 12 patients (16%, 6.4%/y), with a relative risk reduction of 26.4% of that predicted by HAS-BLED. Cardiovascular-related mortality was observed in 2 patients (2.7%). CONCLUSIONS: SAPT appears to be a safe and effective treatment following LAAC in patients at high ischemic and hemorrhagic risk. Further studies are needed to confirm our findings.


Assuntos
Fibrilação Atrial , Oclusão do Apêndice Atrial Esquerdo , Inibidores da Agregação Plaquetária , Idoso , Feminino , Humanos , Masculino , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/cirurgia , Hemorragia/induzido quimicamente , Hemorragia/epidemiologia , Inibidores da Agregação Plaquetária/efeitos adversos , Inibidores da Agregação Plaquetária/uso terapêutico , Estudos Prospectivos , Acidente Vascular Cerebral/epidemiologia , Trombose/epidemiologia , Resultado do Tratamento , Idoso de 80 Anos ou mais
4.
Rev Esp Cardiol (Engl Ed) ; 77(2): 138-147, 2024 Feb.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-37354942

RESUMO

INTRODUCTION AND OBJECTIVES: Catheter-directed therapy (CDT) for acute pulmonary embolism (PE) is an emerging therapy that combines heterogeneous techniques. The aim of the study was to provide a nationwide contemporary snapshot of clinical practice and CDT-related outcomes. METHODS: This Investigator-initiated multicenter registry aimed to include consecutive patients with intermediate-high risk (IHR) or high-risk (HR), acute PE eligible for CDT. The primary outcome of the study was in-hospital all-cause death. RESULTS: A total of 253 patients were included, of whom 93 (36.8%) had HR-PE, and 160 (63.2%) had IHR-PE with a mean age of 62.3±15.1 years. Local thrombolysis was performed in 70.8% and aspiration thrombectomy in 51.8%, with 23.3% of patients receiving both. However, aspiration thrombectomy was favored in the HR-PE cohort (80.6% vs 35%; P<.001). Only 51 patients (20.2%) underwent CDT with specific PE devices. The success rate for CDT was 90.9% (98.1% of IHR-PE patients vs 78.5% of HR-PE patients, P<.001). In-hospital mortality was 15.5%, and was highly concentrated in the HR-PE patients (37.6%) and significantly lower in IHR-PE patients (2.5%), P<.001. Long-term (24-month) mortality was 40.2% in HR-PE patients vs 8.2% in IHR-PE patients (P<.001). CONCLUSIONS: Despite the high success rate for CDT, in-hospital mortality in HR-PE is still high (37.6%) compared with very low IHR-PE mortality (2.5%).


Assuntos
Fibrinolíticos , Embolia Pulmonar , Humanos , Pessoa de Meia-Idade , Idoso , Fibrinolíticos/uso terapêutico , Terapia Trombolítica/métodos , Resultado do Tratamento , Embolia Pulmonar/terapia , Trombectomia/métodos , Catéteres , Sistema de Registros , Estudos Retrospectivos
5.
Catheter Cardiovasc Interv ; 81(3): 446-53, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22109977

RESUMO

OBJECTIVES: To assess the effect of the duration of stent inflation on stent expansion using digital stent enhancement (DSE). BACKGROUND: Optimal stent expansion and apposition to the vessel wall are of critical importance to optimize the results of percutaneous coronary intervention (PCI). However, it is not known if stent inflation duration impacts on stent expansion. METHODS: We performed a prospective cohort study in patients undergoing PCI. Quantitative coronary angiography and DSE data were analyzed. DSE was performed at 5, 15, and 25 sec during stent implantation, after target balloon inflation pressure was achieved. RESULTS: One hundred and four consecutive patients (150 lesions) were enrolled. The mean age was 66.9 ± 11.1 years. Complex lesions (ACC/AHA B2/C) occurred in 26.9%. Stents used: Cypher Select (54.1%), Xience V (30.6%), and Taxus Liberté (15.3%). The minimal stent diameter increased significantly with the duration of stent inflation: 2.60 ± 0.51, 2.76 ± 0.51, and 2.82 ± 0.52 mm at 5, 15, and 25 sec (P < 0.0001). Similarly, maximal stent diameter increased with the duration of stent inflation: 3.21 ± 0.51, 3.32 ± 0.52, and 3.36 ± 0.54 mm (P < 0.0001). The average stent diameter also increased with longer stent inflation (P < 0.0001). Using MUSIC criteria 24.0, 53.3, and 68.0% of stents were appropriately expanded at 5, 15, and 25 sec (P < 0.0001). CONCLUSIONS: The duration of stent balloon inflation has a significant impact on stent expansion. Stent deployment for >25 sec is recommended.


Assuntos
Angioplastia Coronária com Balão/métodos , Angiografia Coronária/métodos , Estenose Coronária/cirurgia , Processamento de Imagem Assistida por Computador/métodos , Ultrassonografia de Intervenção/métodos , Idoso , Estenose Coronária/diagnóstico por imagem , Feminino , Seguimentos , Humanos , Masculino , Duração da Cirurgia , Estudos Prospectivos , Reprodutibilidade dos Testes , Stents
6.
Catheter Cardiovasc Interv ; 80(2): 231-7, 2012 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-22511511

RESUMO

BACKGROUND: As assessment of SYNTAX score is made by visual estimate of coronary angiography, discrepancies between evaluations by different observers and the impact of observer experience have not yet been evaluated. METHODS: Using the data of 166 patients with unprotected left main lesions treated with the second generation everolimus-eluting stent, we sought to analyze SYNTAX score assessment provided by one junior and two independent senior observers and to assess the impact of the quality of angiographies on the reproducibility of SYNTAX score determination. Intra-observer variability was assessed by a senior observer by analyzing 50 sets of angiograms after an interval of at least 6 weeks. RESULTS: The weighted kappa value for the inter-observer reproducibility of SYNTAX score classified as tertiles, according to SYNTAX trial, was 0.71 and the intra-observer weighted kappa value was 0.79. When compared with junior's measurements, SYNTAX score assessed by senior investigators was 0.46 and 0.50. Changes in SYNTAX score classification were arbitrarily responsible for changes in weighted kappa values. Angiograms showing the higher rates of discrepancies between observers were of lower quality, when compared with random angiograms. SYNTAX score was closely correlated to 1-year incidence of major adverse cerebro- and cardiovascular events for both junior and senior readers. CONCLUSIONS: SYNTAX score was slightly underestimated by junior reader, when compared with experienced operators. Inter- and intra-observer reproducibility of experienced operators was very acceptable. SYNTAX score evaluation was clearly related to the quality of angiograms. SYNTAX score was correlated to 1-year incidence of major cardiac and cerebrovascular events (MACCE) in all readers.


Assuntos
Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Intervenção Coronária Percutânea , Fármacos Cardiovasculares/administração & dosagem , Doenças Cardiovasculares/etiologia , Doenças Cardiovasculares/mortalidade , Distribuição de Qui-Quadrado , Competência Clínica , Doença da Artéria Coronariana/mortalidade , Stents Farmacológicos , Everolimo , França/epidemiologia , Humanos , Incidência , Variações Dependentes do Observador , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/instrumentação , Intervenção Coronária Percutânea/mortalidade , Valor Preditivo dos Testes , Desenho de Prótese , Reprodutibilidade dos Testes , Medição de Risco , Fatores de Risco , Sirolimo/administração & dosagem , Sirolimo/análogos & derivados , Fatores de Tempo , Resultado do Tratamento
7.
J Invasive Cardiol ; 34(10): E701-E708, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-36075883

RESUMO

OBJECTIVES: Coronary lithotripsy (CL) works by fracturing the calcified plaque, allowing mean area gain, enhancing vessel compliance, and facilitating stent deployment. This study reports the safety, effectiveness, and durability of the clinical benefit of CL at long-term follow-up of a real-world multicenter registry. METHODS: This was a prospective, multicenter, single-arm study that included consecutive patients with calcified lesions undergoing CL from August, 2018 to October, 2020 with a clinical follow-up of 20 months (interquartile range, 14.5-25). Exclusion criteria were a target lesion located in a vessel <2.5 mm and/or the presence of dissection prior to CL. The primary endpoint was the rate of major adverse cardiovascular event (MACE, defined as death or target-lesion revascularization [TLR] or myocardial infarction [MI]) at follow-up. RESULTS: This registry included 109 patients (128 lesions). The population was elderly (mean age, 74 years old), with high rates of diabetic patients (58%), renal insufficiency (32%), and multivessel disease (76%). Most of the lesions were predilated with semicompliant/noncompliant balloons (25 with cutting balloon). Rotational atherectomy was used in 20 lesions. On average, CL required the use of 1 balloon delivering a mean of 60 pulses. Twelve patients presented with ST-segment-elevation MI and a culprit calcified coronary lesion undergoing CL. Successful CL was achieved in 99% of cases. There were few procedural complications, with 30-day freedom from MACE rate of 98%. The MACE rate at long-term follow-up was 5.6%. CONCLUSION: This is the first real-world, multicenter registry that confirms the safety and long-term efficacy of percutaneous coronary intervention for calcified lesions using CL in an unselected and high-risk population with a low long-term follow-up MACE rate.


Assuntos
Aterectomia Coronária , Doença da Artéria Coronariana , Litotripsia , Intervenção Coronária Percutânea , Calcificação Vascular , Idoso , Aterectomia Coronária/efeitos adversos , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/cirurgia , Seguimentos , Humanos , Litotripsia/efeitos adversos , Intervenção Coronária Percutânea/efeitos adversos , Estudos Prospectivos , Sistema de Registros , Resultado do Tratamento , Calcificação Vascular/diagnóstico , Calcificação Vascular/terapia
8.
Am J Cardiol ; 162: 31-40, 2022 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-34903344

RESUMO

Currently, both drug-eluting stents (DES) and drug-eluting balloons are recommended in patients with in-stent restenosis (ISR) of metallic stents. However, the clinical results of repeated interventions in patients with restenosis of bioresorbable vascular scaffolds (BVS) remain unsettled. We sought to assess the results of interventions in patients with BVS-ISR as compared with those obtained in patients with ISR of DES and bare-metal stents (BMS). Restenosis Intrastent: Treatment of Bioresorbable Vascular Scaffolds Restenosis (RIBS VII) is a prospective multicenter study (23 Spanish sites) that included 117 consecutive patients treated for BVS-ISR. Inclusion/exclusion criteria were similar to those of previous RIBS studies. Patients in the RIBS IV (DES-ISR, n = 309) and RIBS V (BMS - ISR, n = 189) randomized trials, were used as controls. Most patients with BVS-ISR were treated with DES (76%). Patients with BVS-ISR were younger, had larger vessels, and after interventions had higher in-segment residual diameter stenosis (19 ± 13%, 15 ± 11%, 15 ± 12%, p <0.001) than those treated for DES-ISR and BMS-ISR, respectively. At 1-year clinical follow-up (obtained in 100% of patients) target lesion revascularization (6%) was similar to that seen in patients with DES-ISR and BMS-ISR (8.7% and 3.7%, p = 0.32). Freedom from death, myocardial infarction, and target vessel revascularization (primary clinical end point) was 8.5%, also similar to that found in patients with DES-ISR and BMS-ISR (14.2% and 7.4%, p = 0.09). Results were also similar when only patients treated with DES in each group were compared and remained unchanged after adjusting for potential confounders in baseline characteristics. Time to BVS-ISR did not influence angiographic or clinical results. This study demonstrates the safety and efficacy of coronary interventions for patients presenting with BVS-ISR. One-year clinical results in these patients are comparable to those seen in patients with ISR of metallic stents (ClinicalTrials.gov ID:NCT03167424).


Assuntos
Implantes Absorvíveis/efeitos adversos , Doença da Artéria Coronariana/cirurgia , Reestenose Coronária/cirurgia , Oclusão de Enxerto Vascular/cirurgia , Intervenção Coronária Percutânea/efeitos adversos , Stents/efeitos adversos , Idoso , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/mortalidade , Reestenose Coronária/diagnóstico , Reestenose Coronária/epidemiologia , Feminino , Oclusão de Enxerto Vascular/diagnóstico , Oclusão de Enxerto Vascular/epidemiologia , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/instrumentação , Estudos Prospectivos , Reoperação , Fatores de Tempo , Resultado do Tratamento
9.
J Invasive Cardiol ; 33(12): E970-E973, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34783676

RESUMO

BACKGROUND: This study reports procedural and short-term clinical outcomes from a real-world series with the use of coronary lithotripsy in the context of primary angioplasty in ST-segment elevation myocardial infarction (STEMI). METHODS AND RESULTS: This was a prospective registry conducted at 2 hospitals, which included 10 patients who presented a culprit calcified lesion within acute STEMI and underwent coronary lithotripsy during primary angioplasty, between July 2019 and July 2020. Mean age was 69.2 ± 11.8 years, and there was a high proportion of hypertension (70%) and dyslipidemia (60%). All lesions (type B/C) were predilated with a semicompliant balloon. Coronary lithotripsy was performed in all cases once macroscopic thrombus was successfully retrieved by thrombus aspiration catheter. Before lithotripsy, rotational atherectomy was used in 1 case and cutting balloon was used in 2 cases. On average, coronary lithotripsy required the use of 1 lithotripsy balloon (range, 1-2) delivering a mean of 70 pulses. Two lithotripsy balloons were ruptured during lithotripsy therapy without any adverse event. Successful coronary lithotripsy was achieved in 90%. There were no periprocedural cardiac complications. CONCLUSIONS: Coronary lithotripsy seems to be a safe and effective technique in patients with STEMI and a culprit calcified lesion undergoing primary angioplasty for calcium modification in the absence of angiographic thrombus, and a suitable option to achieve adequate stent expansion and apposition.


Assuntos
Litotripsia , Infarto do Miocárdio com Supradesnível do Segmento ST , Idoso , Idoso de 80 Anos ou mais , Angioplastia , Humanos , Pessoa de Meia-Idade , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico , Infarto do Miocárdio com Supradesnível do Segmento ST/cirurgia
10.
J Clin Med ; 10(7)2021 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-33915971

RESUMO

The LAmbreTM device is a novel system designed for left atrial appendage closure (LAAC). First registries showed a high rate of device implantation success. However, few mid-term results are available. We present our 1- and 12-month follow-up results for this device. This prospective, single-center registry included consecutive patients with nonvalvular atrial fibrillation who underwent LAAC with the LAmbreTM device. Transesophageal echocardiography (TEE) was performed at 1-month follow-up. In total, 55 patients were included. The population was elderly (75 ± 9.4 years), with a high proportion of comorbidities. The mean CHA2DS2-VASc and HAS-BLED scores were 4.6 ± 1.6 and 3.9 ± 1.0, respectively. Previous history of a major bleeding event was present in 37 patients (67.3%). Procedural success was achieved in 54 patients (98.2%). Device success was achieved in 100% of patients in whom device implantation was attempted (54 patients). Major in-hospital device-related complications included mortality of one patient (1.8%) and pericardial tamponade in two patients (3.6%); the incidence of stroke was 0%. No thrombus or significant leaks (≥5 mm) were observed on 1-month TEE. At 12 months, adverse events were overall death (1.8%), transient ischemic attack/ischemic stroke (1.8%), and major bleeding events (Bleeding Academic Research Consortium (BARC) 3a and 3c; 11%). In this high-risk population, the LAmbreTM device seems to be a safe and effective option for LAAC with a remarkable mid-term performance.

11.
J Am Heart Assoc ; 10(22): e022123, 2021 11 16.
Artigo em Inglês | MEDLINE | ID: mdl-34729992

RESUMO

Background Early generation drug-eluting stents (DESs) showed a high grade of coronary endothelial dysfunction that was attributed to lack of stent reendothelialization. Endothelium-dependent vasomotor response of current DESs and bioresorbable scaffolds (BRSs) remains unknown. This study sought to assess the device-related endothelial function of current devices and to correlate neointima healing with endothelial function. Methods and Results A total of 206 patients from 4 randomized trials treated with the durable-polymer everolimus-eluting Xience (n=44), bioresorbable-polymer sirolimus-eluting Orsiro (n=35), polymer-free biolimus-eluting Biofreedom (n=24), bioactive endothelial-progenitor cell-capturing sirolimus-eluting Combo DES (n=25), polymer-based everolimus-eluting Absorb (n=44), and Mg-based sirolimus-eluting Magmaris BRS (n=34) underwent endothelium-dependent vasomotor tests and optical coherence tomography imaging, as per protocol, at follow-up. Crude vasomotor responses of distal segments to low-dose acetylcholine (10-6 mol/L) were different between groups: bioresorbablepolymer DEShad the worst (-8.4%±12.6%) and durable-polymer DES had the most physiologic (-0.4%±11.8%; P=0.014). High-dose acetylcholine (10-4 mol/L) showed similar responses between groups (ranging from -10.8%±11.6% to -18.1%±15.4%; P=0.229). Device healing was different between devices. Uncovered struts ranged from 6.3%±7.1% (bioresorbable-polymer DES) to 2.5%±4.5% (bioactive DES; P=0.056). In multivariate models, endothelium-dependent vasomotor response was associated with age, bioresorbable-polymer DES, and angiographic lumen loss, but not with strut coverage nor plaque type. Endothelial dysfunction (defined as ≥4% vasoconstriction) was observed in 46.6% of patients with low-dose and 68.9% with high-dose acetylcholine, without differences between groups. Conclusions At follow-up, endothelial dysfunction was frequently observed in distal segments treated with current stents without remarkable differences between devices. Although neointima healing was different between devices, poor healing was not associated with endothelial dysfunction.


Assuntos
Stents Farmacológicos , Intervenção Coronária Percutânea , Implantes Absorvíveis , Acetilcolina , Angiografia Coronária , Endotélio , Everolimo , Humanos , Neointima , Polímeros , Desenho de Prótese , Sirolimo , Resultado do Tratamento
12.
Rev Esp Cardiol (Engl Ed) ; 74(12): 1013-1022, 2021 Dec.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-33640311

RESUMO

INTRODUCTION AND OBJECTIVES: The vasomotor function of new-generation drug-eluting stents designed to enhance stent healing and reendothelialization is unknown. This study aimed to compare the endothelial function of the infarct-related artery (IRA) treated with bioactive circulating endothelial progenitor cell-capturing sirolimus-eluting stents (COMBO) vs polymer-free biolimus-eluting stents (BioFreedom) in ST-segment elevation myocardial infarction patients at 6 months. Secondary objectives were to compare the microcirculatory function of the IRA and stent healing at 6 months. METHODS: Sixty patients were randomized to bioactive sirolimus-eluting stent vs polymer-free biolimus-eluting stents implantation. At 6 months, patients underwent coronary angiography with vasomotor, microcirculatory and optical coherence tomography examinations. Endothelial dysfunction of the distal coronary segment was defined as ≥ 4% vasoconstriction to intracoronary acetylcholine infusion. RESULTS: Endothelial dysfunction was similarly observed between groups (64.0% vs 62.5%, respectively; P=.913). Mean lumen diameter decreased by 16.0 ±20.2% vs 16.1 ±21.6% during acetylcholine infusion (P=.983). Microcirculatory function was similar in the 2 groups: coronary flow reserve was 3.23 ±1.77 vs 3.23±1.62 (P=.992) and the index of microcirculatory resistance was 24.8±16.8 vs 21.3±12.0 (P=.440). Optical coherence tomography findings were similar: uncovered struts (2.3% vs 3.2%; P=.466), malapposed struts (0.1% vs 0.3%; P=.519) and major evaginations (7.1% vs 5.6%; P=.708) were observed in few cases. CONCLUSIONS: Endothelial dysfunction of the IRA was frequent and was similarly observed with new-generation drug-eluting stents designed to enhance stent reendothelialization at 6 months. Endothelial dysfunction was observed despite almost preserved microcirculatory function and complete stent coverage. Larger and clinically powered studies are needed to assess the role of residual endothelial dysfunction in ST-segment elevation myocardial infarction patients. Registered in ClinicalTrials.gov: NCT04202172.


Assuntos
Stents Farmacológicos , Intervenção Coronária Percutânea , Angiografia Coronária , Células Endoteliais , Humanos , Microcirculação , Polímeros , Desenho de Prótese , Sirolimo/farmacologia , Tomografia de Coerência Óptica , Resultado do Tratamento
13.
Indian Heart J ; 62(3): 206-10, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-21275293

RESUMO

The transradial approach (TRA) is being increasingly adopted in Europe, and is currently implemented in 60% of angioplasty procedures in France. This vascular route improves the comfort of the patient as well as that of the paramedical staff whilst allowing a reduction in hospitalization duration and cost. Most importantly, it reduces the risk of vascular and bleeding complications with a potential impact on mid-term mortality. With the classical transfemoral approach, certain patients are more prone to access site complications (elderly patients, women, severely obese patients). These population is also the same in which the TRA is the most difficult to perform. For this reason, operators are advised to start their learning period with the easiest cases: a palpable radial artery in a young patient in a non-emergency setting. Though the radial artery is a small vessel, slightly less than 3 mm in diameter, it is large enough to accommodate devices for simple and complex angioplasties such as bifurcations with kissing balloons, rotablator procedures and saphenous venous graft angioplasty with distal protection devices. A negative Allen test used to be considered an absolute contraindication to the TRA. In fact, assessment of the palmar arches using pulse oxymetry examination is now recommended. It is more sensible and less frequently negative. However, given the low risk of radial occlusion and the extremely low morbidity rate, the patency of the palmar arch is less frequently tested in "radial" centres. The TRA is already the gold standard approach in some countries in Europe. It requires specific practice in order to avoid a number of pitfalls such as spasm, which can be almost completely avoided by a good prevention, anatomic difficulties, which can be easily solved by a good knowledge of anatomic variations.


Assuntos
Angioplastia Coronária com Balão/métodos , Cateterismo Cardíaco/métodos , Cateterismo Periférico/métodos , Artéria Radial , Anestesia/métodos , Artéria Femoral , Humanos , Seleção de Pacientes , Punções/métodos , Grau de Desobstrução Vascular
14.
EuroIntervention ; 16(2): e155-e163, 2020 06 12.
Artigo em Inglês | MEDLINE | ID: mdl-31217148

RESUMO

AIMS: The aim of this study was to compare the hyperaemic flow and vasomotor response to endothelium-dependent stimuli between bioresorbable vascular scaffolds (BVS) and metallic everolimus-eluting stents (EES) at 13 months. METHODS AND RESULTS: Seventy non-diabetic patients aiming to achieve complete revascularisation were randomised 1:1 to BVS or EES implantation. At 13 months, invasive coronary angiography was performed using intracoronary pressure and Doppler ultrasound measurements at rest and maximal hyperaemia. A vasomotor test to endothelium-dependent (acetylcholine) and independent (nitroglycerine) stimuli and optical coherence tomography (OCT) were also performed. Fifty-nine patients (30 BVS and 29 EES) underwent 13-month examination. Doppler ultrasound average peak velocity (49.0±17.5 vs 49.3±18.3 cm/sec; p=0.95), coronary blood flow (97.4±53.5 vs 88.3±46.7 ml/min; p=0.51), coronary flow reserve (2.6±0.9 vs 2.7±0.8; p=0.84) and fractional flow reserve (0.92±0.06 vs 0.94±0.04; p=0.17) were similar between the groups. The vasomotor test showed vasoconstriction response to acetylcholine in 75.6% proximal and 72.2% distal peri-scaffold segments without differences between study devices. BVS had larger in-scaffold vasoconstriction than EES (60.0% vs 27.6%; p=0.01) despite similar neointima response as assessed by OCT. CONCLUSIONS: BVS and EES had similar microcirculatory response to hyperaemia and predominant vasoconstrictive response in the peri-scaffold segments to endothelium-dependent stimuli. However, BVS exhibited larger vasoconstriction to endothelium-dependent stimuli in the scaffold segment.


Assuntos
Implantes Absorvíveis , Stents Farmacológicos , Everolimo/administração & dosagem , Hiperemia/diagnóstico por imagem , Microcirculação/efeitos dos fármacos , Intervenção Coronária Percutânea , Alicerces Teciduais , Angiografia Coronária , Everolimo/uso terapêutico , Humanos , Hiperemia/terapia , Desenho de Prótese , Resultado do Tratamento , Ultrassonografia Doppler
15.
Rev Esp Cardiol (Engl Ed) ; 73(12): 1003-1010, 2020 Dec.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-32430261

RESUMO

INTRODUCTION AND OBJECTIVES: Coronary lithoplasty (CL) is a balloon-based technique used to treat calcified lesions. This study reports the initial experience of treatment of calcified lesions with CL in an unselected and high-risk population. METHODS: This was a prospective, multicenter registry, which included all consecutive cases with calcified coronary lesions that underwent CL between August, 2018 and August, 2019. Exclusion criteria consisted of a target lesion located in a small vessel (< 2.5mm) and the presence of dissection prior to CL. Quantitative coronary angiography and intravascular ultrasound/optical coherence tomography analysis were completed by an independent central core laboratory. RESULTS: This registry included 57 patients (66 lesions). The population was elderly (72.6±9.4 years) with high proportions of patients with diabetes (56%), chronic kidney disease (35%), and multivessel disease (84%). All lesions were classified as type B/C. More than 75% of lesions were predilated with noncompliant/semicompliant balloons or cutting-balloon. Rotablator was used in 5 lesions (7.6%) prelithoplasty. On average, CL required 1.17 balloons delivering a mean of 60 pulses. Successful CL was achieved in 98%. In 13% of cases, lithoplasty balloon was broken during therapy. There were few procedural complications: 2 cases of significant dissections (none related to lithoplasty balloon rupture) were successfully treated with drug-eluting stent implantation. One patient experienced stent thrombosis 2 days after successfully undergoing target lesion revascularization. CONCLUSIONS: This is a real-world multicenter registry, which supports the feasibility, safety, and short-term efficacy of PCI for calcified coronary lesions using CL in an unselected and high-risk population with promising results.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Litotripsia , Intervenção Coronária Percutânea , Calcificação Vascular , Idoso , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/cirurgia , Humanos , Estudos Prospectivos , Sistema de Registros , Resultado do Tratamento , Calcificação Vascular/diagnóstico , Calcificação Vascular/cirurgia
16.
Rev Esp Cardiol (Engl Ed) ; 72(12): 1005-1011, 2019 Dec.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-30297278

RESUMO

BACKGROUND AND OBJECTIVES: Patients older than 75 years with ST-segment elevation myocardial infarction undergoing primary angioplasty in cardiogenic shock have high mortality. Identification of preprocedural predictors of short- and long-term mortality could be useful to guide decision-making and further interventions. METHODS: We analyzed a nationwide registry of primary angioplasty in the elderly (ESTROFA MI+75) comprising 3576 patients. The characteristics and outcomes of the subgroup of patients in cardiogenic shock were analyzed to identify associated factors and prognostic predictors in order to derive a baseline risk prediction score for 1-year mortality. The score was validated in an independent cohort. RESULTS: A total of 332 patients were included. Baseline independent predictors of mortality were anterior myocardial infarction (HR 2.8, 95%CI, 1.4-6.0 P=.005), ejection fraction<40% (HR 2.3, 95%CI, 1.14-4.50 P=.018), and time from symptom onset to angioplasty >6hours (HR 3.2, 95%CI, 1.6-7.5; P=.001). A score was designed that included these predictive factors (score "6-ANT-40"). Survival at 1 year was 54.5% for patients with score 0, 32.3% for score 1, 27.4% for score 2 and 17% for score 3 (P=.004, c-statistic 0.70). The score was validated in an independent cohort of 124 patients, showing 1-year survival rates of 64.5%, 40.0%, 28.9%, and 22.2%, respectively (P=.008, c-statistic 0.68). CONCLUSIONS: A preprocedural score based on 3 simple clinical variables (anterior location, ejection fraction<40%, and delay time >6 hours) may be used to estimate survival after primary angioplasty in elderly patients with cardiogenic shock and to guide preinterventional decision-making.


Assuntos
Angioplastia Coronária com Balão/métodos , Tomada de Decisões , Sistema de Registros , Medição de Risco/métodos , Infarto do Miocárdio com Supradesnível do Segmento ST/cirurgia , Choque Cardiogênico/epidemiologia , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Mortalidade Hospitalar/tendências , Humanos , Masculino , Prognóstico , Estudos Retrospectivos , Fatores de Risco , Infarto do Miocárdio com Supradesnível do Segmento ST/complicações , Infarto do Miocárdio com Supradesnível do Segmento ST/epidemiologia , Choque Cardiogênico/etiologia , Espanha/epidemiologia , Taxa de Sobrevida/tendências , Fatores de Tempo
17.
Rev Esp Cardiol (Engl Ed) ; 71(5): 335-343, 2018 May.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-28870640

RESUMO

INTRODUCTION AND OBJECTIVES: Stent thrombosis (ST) is a life-threatening complication after stent implantation. Intravascular ultrasound is able to discern most causes of ST. The aim of this study was to compare intravascular ultrasound findings between bare-metal stents (BMS) and drug-eluting stents (DES) in patients with late (31 days to 1 year) or very late ST (> 1 year). METHODS: Of 250 consecutive patients with late or very late ST in 7 Spanish institutions, 114 patients (45.5% BMS and 54.5% DES) were imaged with intravascular ultrasound. Off-line intravascular ultrasound analysis was performed to assess malapposition, underexpansion, and neoatherosclerosis. RESULTS: The median time from stent implantation to ST was 4.0 years with BMS and 3.4 years with DES (P = .04). Isolated malapposition was similarly observed in both groups (36.5% vs 46.8%; P = .18) but was numerically lower with BMS (26.6% vs 48.0%; P = .07) in patients with very late ST. Isolated underexpansion was similarly observed in both groups (13.5% vs 11.3%; P = .47). Isolated neoatherosclerosis occurred only in patients with very late ST and was more prevalent with BMS (22.9%) than with DES (6.0%); P = .02. At 2.9 years' follow-up, there were 0% and 6.9% cardiac deaths, respectively (P = .06) and recurrent ST occurred in 4.0% and 5.2% of patients, respectively (P = .60). CONCLUSIONS: Malapposition was the most common finding in patients with late and very late ST and is more prevalent with DES in very late ST. In contrast, neoatherosclerosis was exclusively observed in patients with very late ST and mainly with BMS.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Trombose Coronária/diagnóstico por imagem , Trombose Coronária/terapia , Stents Farmacológicos , Falha de Prótese , Ultrassonografia de Intervenção , Idoso , Angioplastia Coronária com Balão/métodos , Estudos de Coortes , Angiografia Coronária/métodos , Trombose Coronária/mortalidade , Feminino , Seguimentos , Humanos , Estimativa de Kaplan-Meier , Masculino , Metais , Pessoa de Meia-Idade , Estudos Retrospectivos , Medição de Risco , Espanha , Estatísticas não Paramétricas , Taxa de Sobrevida , Trombose/diagnóstico por imagem , Trombose/epidemiologia , Fatores de Tempo , Resultado do Tratamento
18.
Cardiovasc Revasc Med ; 19(5 Pt B): 580-588, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29306670

RESUMO

BACKGROUND: In elderly patients with ST elevated myocardial infarction (STEMI) and multivessel disease (MVD the outcomes related with different revascularization strategies are not well known. METHODS: Subgroup-analysis of a nation-wide registry of primary angioplasty in the elderly (ESTROFA MI+75) with 3576 patients over 75years old from 31 centers. Patients with MVD were analyzed to describe treatment approaches and 2years outcomes. RESULTS: Of 1830 (51%) with MVD, 847 (46%) underwent multivessel revascularization either in acute (51%), staged (44%) or both procedures (5%). Patients with previous myocardial infarction and those receiving drug-eluting stents or IIb-IIIa inhibitors were more prone to be revascularized, whereas older patients, females and those with Killip III-IV, renal failure and higher ejection fraction were less likely. Survival free of cardiac death and infarction at 2years was better for those undergoing multivessel PCI (85.8% vs. 80.4%, p<0.0008), regardless of Killip class. Multivessel PCI was protective of cardiac death and infarction (HR 0.60, 95% CI 0.40-0.89; p=0.011). Complete revascularization made no difference in outcomes among those patients undergoing multivessel PCI. The best prognosis corresponded to those undergoing multivessel PCI in staged procedures (p<0.001). A propensity score matching analysis (514 patients in each group) yielded similar results. CONCLUSIONS: In elderly patients with STEMI and MVD, multivessel PCI was related with better outcomes especially after staged procedures. Among those undergoing multivessel PCI, anatomically defined completeness of revascularization had not prognostic influence. SUMMARY: We sought to investigate the revascularization strategies applied and their prognostic implications in patients aged over 75years with ST elevated myocardial infarction showing multivessel disease. Of 1830 patients, 847 (46%) underwent multivessel PCI either in acute (51%), staged (44%) or both procedures (5%). Multivessel PCI was independent predictor of cardiac death and infarction with the best prognosis corresponding to those undergoing staged procedures.


Assuntos
Doença da Artéria Coronariana/cirurgia , Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST/cirurgia , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Stents Farmacológicos , Feminino , Humanos , Masculino , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/instrumentação , Intervenção Coronária Percutânea/mortalidade , Inibidores da Agregação Plaquetária/uso terapêutico , Intervalo Livre de Progressão , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico por imagem , Infarto do Miocárdio com Supradesnível do Segmento ST/mortalidade , Espanha , Fatores de Tempo
20.
Rev Esp Cardiol (Engl Ed) ; 70(2): 81-87, 2017 Feb.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-27840148

RESUMO

INTRODUCTION AND OBJECTIVES: The proportion of elderly patients undergoing primary angioplasty is growing. The present study describes the clinical profile, procedural characteristics, outcomes, and predictors of outcome. METHODS: A 31-center registry of consecutive patients older than 75 years treated with primary angioplasty. Clinical and procedural data were collected, and the patients underwent clinical follow-up. RESULTS: The study included 3576 patients (39.3% women, 48.5% with renal failure, 11.5% in Killip III or IV, and 29.8% with>6hours of chest pain). Multivessel disease was present in 55.4% and nonculprit lesions were additionally treated in 24.8%. Radial access was used in 56.4%, bivalirudin in 11.8%, thromboaspiration in 55.9%, and drug-eluting stents in 26.6%. The 1-month and 2-year incidences of cardiovascular death were 10.1% and 14.7%, respectively. The 2-year rates of definite or probable thrombosis, repeat revascularization, and BARC bleeding>2 were 3.1%, 2.3%, and 4.2%, respectively. Predictive factors were diabetes mellitus, renal failure, atrial fibrillation, delay to reperfusion>6hours, ejection fraction<45%, Killip class III-IV, radial access, bivalirudin, drug-eluting stents, final TIMI flow of III, and incomplete revascularization at discharge. CONCLUSIONS: Notable registry findings include frequently delayed presentation and a high prevalence of adverse factors such as renal failure and multivessel disease. Positive procedure-related predictors include shorter delay, use of radial access, bivalirudin, drug-eluting stents, and complete revascularization before discharge.


Assuntos
Angioplastia Coronária com Balão/métodos , Stents Farmacológicos , Sistema de Registros , Insuficiência Renal/epidemiologia , Infarto do Miocárdio com Supradesnível do Segmento ST/cirurgia , Idoso , Idoso de 80 Anos ou mais , Causas de Morte/tendências , Comorbidade , Feminino , Seguimentos , Humanos , Masculino , Prognóstico , Recidiva , Estudos Retrospectivos , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico , Infarto do Miocárdio com Supradesnível do Segmento ST/epidemiologia , Espanha/epidemiologia , Taxa de Sobrevida/tendências , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa