Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 44
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Clin Ethics ; 35(3): 199-201, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39145577

RESUMO

AbstractPsychiatric treatment options, such as electroconvulsive therapy (ECT), can be lifesaving for individuals suffering from severe mental illness. For individuals who are unable to make or communicate their own medical decisions, this decision may fall on a legal guardian, who will make decisions on the patient's behalf. Here we discuss the considerations of end-of-life planning in a patient with severe mental illness under guardianship when treatment modalities, in this case ECT, are no longer effective.


Assuntos
Eletroconvulsoterapia , Cuidados Paliativos , Assistência Terminal , Veteranos , Humanos , Feminino , Idoso , Tutores Legais , Tomada de Decisões , Depressão/terapia , Planejamento Antecipado de Cuidados
2.
Catheter Cardiovasc Interv ; 101(1): 187-196, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36378620

RESUMO

BACKGROUND: New-onset left bundle branch block (LBBB) can develop after transcatheter aortic valve replacement (TAVR) resulting in worse outcomes. AIMS: Describe clinical and echocardiographic outcomes with new-onset LBBB after TAVR. METHODS: We included consecutive patients who underwent transfemoral-TAVR with SAPIEN-3 (S3) valve between April 2015 and December 2018. Exclusion criteria included pre-existing LBBB, right BBB, left anterior hemiblock, left posterior hemiblock, wide QRS ≥ 120ms, prior permanent pacemaker (PPM), and nontransfemoral access. RESULTS: Among 612 patients, 11.4% developed new-onset LBBB upon discharge. The length of stay was longer with new-onset LBBB compared with no LBBB [3 (2-5) days versus 2 (1-3) days; p < 0.001]. New-onset LBBB was associated with higher rates of 30-day PPM requirement (18.6% vs. 5.4%; p < 0.001) and 1-year heart failure hospitalizations (10.7% vs. 4.4%; p = 0.033). There was no difference in 3-year mortality between both groups (30.9% vs. 30.6%; p = 0.829). Further, new-onset LBBB was associated with lower left ventricular ejection fraction (LVEF) at both 30 days (55.9 ± 11.4% vs. 59.3 ± 9%; p = 0.026) and 1 year (55 ± 12% vs. 60.1 ± 8.9%; p = 0.002). These changes were still present when we stratified patients according to baseline LVEF (≥50% or <50%). New-onset LBBBs were associated with a higher 1-year LV end-diastolic volume index (51.4 ± 18.6 vs. 46.4 ± 15.1 ml/m2 ; p = 0.036), and LV end-systolic volume index (23.2 ± 14.1 vs. 18.9 ± 9.7 ml/m2 ; p = 0.009). Compared with resolved new-onset LBBB, persistent new-onset LBBB was associated with worse LVEF and higher PPM at 1 year. CONCLUSIONS: New-onset LBBB after S3 TAVR was associated with higher PPM requirement, worse LVEF, higher LV volumes, and increased heart failure hospitalizations, with no difference in mortality.


Assuntos
Estenose da Valva Aórtica , Insuficiência Cardíaca , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/etiologia , Bloqueio de Ramo/terapia , Volume Sistólico , Função Ventricular Esquerda , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Arritmias Cardíacas , Ecocardiografia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia
3.
Europace ; 25(5)2023 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-37021812

RESUMO

AIMS: To evaluate the efficacy of oesophageal cooling in the prevention of oesophageal injury in patients undergoing atrial fibrillation (AF) catheter ablation. METHODS AND RESULTS: Comprehensive search of MEDLINE, EMBASE, and Cochrane databases through April 2022 for randomized controlled trials (RCTs) evaluating the role of oesophageal cooling compared with control in the prevention of oesophageal injury during AF catheter ablation. The study primary outcome was the incidence of any oesophageal injury. The meta-analysis included 4 RCTs with a total of 294 patients. There was no difference in the incidence of any oesophageal injury between oesophageal cooling and control [15% vs. 19%; relative risk (RR) 0.86; 95% confidence interval (CI) 0.31-2.41]. Compared with control, oesophageal cooling showed lower risk of severe oesophageal injury (1.5% vs. 9%; RR 0.21; 95% CI 0.05-0.80). There were no significant differences among the two groups in mild to moderate oesophageal injury (13.6% vs. 12.1%; RR 1.09; 95% CI 0.28-4.23), procedure duration [standardized mean difference (SMD) -0.03; 95% CI -0.36-0.30], posterior wall radiofrequency (RF) time (SMD 0.27; 95% CI -0.04-0.58), total RF time (SMD -0.50; 95% CI -1.15-0.16), acute reconnection incidence (RR 0.93; 95% CI 0.02-36.34), and ablation index (SMD 0.16; 95% CI -0.33-0.66). CONCLUSION: Among patients undergoing AF catheter ablation, oesophageal cooling did not reduce the overall risk of any oesophageal injury compared with control. Oesophageal cooling might shift the severity of oesophageal injuries to less severe injuries. Further studies should evaluate the long-term effects after oesophageal cooling during AF catheter ablation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Doenças do Esôfago , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ensaios Clínicos Controlados Aleatórios como Assunto , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Resultado do Tratamento
4.
J Card Fail ; 28(7): 1222-1226, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35318127

RESUMO

BACKGROUND: There are limited data regarding the management of guideline-directed medical therapy (GDMT) for heart failure with reduced ejection fraction (HFrEF) with virtual visits in comparison with in-office visits. We sought to compare the changes in GDMT (angiotensin-converting enzyme inhibitors, angiotensin II receptor blockers, angiotensin receptor neprilysin inhibitors, mineralocorticoid receptor antagonists, and sodium glucose cotransporter-2 inhibitors) and loop diuretics across visit types. METHODS AND RESULTS: This study included 13,481 outpatient visits performed for 5439 unique patients with HFrEF between March 16, 2020, and March 15, 2021. The rates of initiation and discontinuation of GDMT were documented, and multivariable logistic regression was performed to test associations with outcomes between modes of visit. The rates of medication initiation were higher in office (11.7%) compared with video (9.6%) or telephone (7.2%) visits. In multivariable adjusted analysis, the initiation of at least 1 GDMT class was similar between in-office visits and video visits (adjusted odds ratio [OR] 0.97, 95% confidence interval [CI] 0.82-1.14, P = .703). Telephone visits were associated with less frequent initiation of at least 1 class of GDMT in comparison with in-office visits (adjusted OR 0.64, 95% CI 0.55-0.75; P < .001) and video visits (adjusted OR 0.67, 95% CI 0.55-0.81, P < .001). Despite similar rates of baseline loop diuretic use, patients seen with both video visits (adjusted OR 0.70, 95% CI 0.52-0.94, P = .018) and telephone visits (adjusted OR 0.64, 95% CI 0.49-0.83, P < .001) were less likely to have a loop diuretic initiated when compared with in-office visits. CONCLUSIONS: The initiation of GDMT for HFrEF was similar between in-office and video visits and lower with telephone visits, whereas the initiation of a loop diuretic was less frequent in both types of virtual visits. These data suggest that video streaming capabilities should be encouraged for virtual visits.


Assuntos
Insuficiência Cardíaca , Telemedicina , Antagonistas Adrenérgicos beta/uso terapêutico , Antagonistas de Receptores de Angiotensina/farmacologia , Antagonistas de Receptores de Angiotensina/uso terapêutico , Insuficiência Cardíaca/tratamento farmacológico , Insuficiência Cardíaca/epidemiologia , Humanos , Pacientes Ambulatoriais , Inibidores de Simportadores de Cloreto de Sódio e Potássio/uso terapêutico , Volume Sistólico , Telefone
5.
Catheter Cardiovasc Interv ; 99(5): 1636-1644, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35132765

RESUMO

BACKGROUND: There is a paucity of data regarding the sex-related differences in the trends and outcomes of trans-septal transcatheter mitral valve replacement (TS-TMVR). METHODS: The Nationwide Readmissions Database (2015-2018) was queried for admissions for TS-TMVR. Propensity matched analysis was conducted to compare outcomes with hospitalizations for TS-TMVR among women versus men. The main study outcome was in-hospital mortality. RESULTS: Our final analysis included 2063 hospitalizations for TS-TMVR; of whom, 58.1% were women. The proportion of women among those undergoing TS-TMVR increased from 50% in 2015 to 60.2% in 2018 (Ptrend = 0.04). Compared with men, women undergoing TS-TMVR were slightly younger, and had a distinct profile of comorbidities. After matching, there was no significant difference in in-hospital mortality among women versus men undergoing TS-TMVR (7.8% vs. 6.1%, OR = 1.30; 95% CI: 0.79-2.13). Subgroup analyzes showed an interaction toward higher mortality with women versus men among patients with CKD (Pinteraction = 0.07). There were no significant differences between women and men in in-hospital complications or length of stay after TS-TMVR. Compared with men, women undergoing TS-TMVR were more likely to be discharged to a nursing facility (17.7% vs. 11.5%, p = 0.01) and had higher rates of 30-day readmissions (22.4% vs. 13.6%, p = 0.01). CONCLUSION: This nationwide analysis showed an increase in the proportion of women among patients undergoing TS-TMVR during the study years. There were no differences in in-hospital mortality, in-hospital complications, or length of stay between both sexes following TS-TMVR. Women were more likely to be discharged to nursing facilities and had higher rates of readmission at 30 days even after propensity matching.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Cateterismo Cardíaco/efeitos adversos , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Masculino , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/cirurgia , Readmissão do Paciente , Resultado do Tratamento
6.
J Card Fail ; 27(7): 812-815, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33753241

RESUMO

BACKGROUND: Statins are recommended in heart transplant patients, but are sometimes poorly tolerated. Alternative agents are often considered including proprotein convertase subtilisin/kexin type-9 inhibitors (PCSK9i). We sought to investigate the use of PCSK9i after heart transplantation. METHODS AND RESULTS: We identified patients who received a heart transplant from 1999 to 2019 and were started on PCSK9i at our institution. Clinical, laboratory, and coronary angiography with intravascular ultrasound results were compared. Among 65 patients initiated on PCSK9i (48 for statin intolerance and 17 for refractory hyperlipidemia), the median time from transplant was 5.5 years (interquartile range [IQR], 2.8-9.9 years) with a median PCSK9 treatment duration of 1.6 years (IQR, 0.8-3.2 years) and 80% still on treatment. Evolocumab was used in 73.8%, alirocumab in 12.3%, and both in 13.8% owing to insurance coverage. All patients required prior authorization; initial denial occurred in 18.5% and 32.3% had denials in subsequent years. The median low-density lipoprotein cholesterol decreased from 130 mg/dL (IQR, 102-148 mg/dL) to 55 mg/dL (IQR, 35-74 mg/dL) after starting PCSK9i (P < .001), with 72% of patients achieving a low-density lipoprotein cholesterol of <70 mg/dL after treatment. There were also significant reductions of total cholesterol, non-high-density lipoprotein cholesterol, total/high-density lipoprotein cholesterol ratio, and triglycerides, with a modest increase in high-density lipoprotein cholesterol. These changes were durable at latest follow-up. In 33 patients with serial coronary angiography and intravascular ultrasound, PCSK9i were associated with stable coronary plaque thickness and lumen area. CONCLUSIONS: Among heart transplant recipients, PCSK9i are effective in lowering cholesterol levels and stabilizing coronary intimal hyperplasia with minimal side effects. Despite favorable effects, access and affordability remain a challenge.


Assuntos
Insuficiência Cardíaca , Transplante de Coração , Inibidores de PCSK9 , LDL-Colesterol , Humanos , Transplantados
7.
Catheter Cardiovasc Interv ; 98(1): E127-E138, 2021 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-33010100

RESUMO

BACKGROUND: Baseline conduction abnormalities are known risk factors for permanent pacemaker (PPM) implantation after transcatheter aortic valve replacement (TAVR). We sought to determine the impact of baseline right bundle branch block (RBBB), left bundle branch block (LBBB), left anterior hemiblock (LAHB), first-degree atrioventricular block (AVB) and atrial fibrillation/flutter (AF) on TAVR outcomes. METHODS: Consecutive patients who underwent transfemoral TAVR with SAPIEN-3 (S3) were included. We excluded patients with prior PPM, nontransfemoral access or valve-in-valve. RESULTS: Among 886 patients, baseline RBBB was seen in 15.9%, LBBB in 6.3%, LAHB in 6.2%, first-degree AVB in 26.3% and AF in 37.5%. The rate of 30-day PPM was 10.1%. Baseline RBBB (OR 4.005; 95% CI 2.386-6.723; p < .001) and first-degree AVB (OR 1.847; 95% CI 1.133-3.009; p = .014) were independent predictors of 30 day PPM. LAHB also resulted in higher PPM rates but only in unadjusted analysis (21.8% vs. 9.4%; p = .003). Baseline LBBB and AF were associated with lower left ventricular ejection fraction (LVEF) at both baseline and 1 year after TAVR. However, Δ LVEF over time were noted to be similar with baseline LBBB (1.8% vs. 1.4%; p = .809) and AF (1.1% vs. 1.7%; p = .458). Moreover, baseline AF was also associated with higher stroke/transient ischemic attack (TIA) at 1 year (4.4% vs. 1.8%; p = .019), 1-year major adverse cardiac and cerebrovascular events (MACCE) (19.5% vs. 13.3%; p = .012) and 2 year mortality (23.5% vs. 15.2%; p = .016). None of the other baseline conduction defects affected long-term mortality or MACCE. CONCLUSION: In our S3 TAVR population, baseline RBBB and first-degree AVB predicted higher PPM risk. Prior LBBB and AF were associated with lower LVEF at both baseline and 1 year. Lastly, preexisting AF was associated with higher rates of mortality, stroke/TIA, and MACCE.


Assuntos
Estenose da Valva Aórtica , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Fatores de Risco , Volume Sistólico , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Função Ventricular Esquerda
8.
Catheter Cardiovasc Interv ; 98(3): E436-E443, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33512085

RESUMO

BACKGROUND: Monitored anesthesia care (MAC) has become more widely used during transcatheter aortic valve replacement (TAVR) to avoid the complications of general anesthesia (GA). METHODS: We included consecutive patients who underwent transfemoral-TAVR at our institution between January 2012 and April 2017. We compared outcomes with GA versus MAC. RESULTS: Of 998 patients, MAC was used in 43.9%. MAC was associated with shorter procedural time (96.9 ± 30.9 vs. 135 ± 64.6 mins; p < .001), fluoroscopy time (20.4 ± 8.9 vs. 29 ± 18.7 mins; p < .001), lower contrast volume (45.5 ± 27 vs. 60.4 ± 43 cc; p < .001), and decreased radiation exposure (12,869 ± 8,099 vs. 20,630 ± 16,276 cGy-cm2 ; p < .001). Patients who underwent MAC had a briefer median (IQR) intensive care unit stay [23.3 (21-24) vs. 23.4 (20.8-26) hrs; p < .001], and hospital stay [2 (2, 3) vs. 3 (2-6) days; p < .001], and were more frequently discharged to home (93.4% vs. 82.9%; p < .001). MAC was associated with lower mortality at 30 days (0.5% vs. 2.9%; log-rank p = .012; adjHR 0.22, 95% CI 0.06-0.82; p = .024), but not at 1 year (11.7% vs. 14.6%; log-rank p = .157) or 3 years (36.8% vs. 38.4%; log-rank p = 0.433). There were no differences in major adverse cardiac and cerebrovascular events (MACCE) at either 30 days (4.6% vs. 9.3%; log-rank p = .14) or 1 year (21.1% vs. 21.5%; log-rank p = .653). Similar findings were seen among patients who received newer-generation SAPIEN-3 valves. CONCLUSION: Utilizing MAC and omitting intraprocedural transesophageal echocardiography during TAVR seems to be more efficient without compromising safety. Better TAVR outcomes can be achieved with newer generation valves without needing GA.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Anestesia Geral/efeitos adversos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Fluoroscopia , Humanos , Tempo de Internação , Estudos Retrospectivos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
9.
Catheter Cardiovasc Interv ; 97(3): 529-539, 2021 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-32845036

RESUMO

BACKGROUND: There is a paucity of data regarding the optimum timing of PCI in relation to TAVR. OBJECTIVE: We compared the major adverse cardiovascular and cerebrovascular events (MACCE) rates among patients who underwent percutaneous coronary intervention (PCI) before transcatheter aortic valve replacement (TAVR) with those who received PCI with/after TAVR. METHODS: In this multicenter study, we pooled all consecutive patients who underwent TAVR at three high volume centers. RESULTS: Among 3,982 patients who underwent TAVR, 327 (8%) patients underwent PCI within 1 year before TAVR, 38 (1%) had PCI the same day as TAVR and 15 (0.5%) had PCI within 2 months after TAVR. Overall, among patients who received both PCI and TAVR (n = 380), history of previous CABG (HR:0.501; p = .001), higher BMI at TAVR (HR:0.970; p = .038), and statin therapy after TAVR (HR:0.660, p = .037) were independently associated with lower MACCE while warfarin therapy after TAVR was associated with a higher risk of MACCE (HR:1.779, p = .017). Patients who received PCI within 1 year before TAVR had similar baseline demographics, STS scores, clinical risk factors when compared to patients receiving PCI with/after TAVR. Both groups were similar in PCI (Syntax Score, ACC/AHA lesion class) and TAVR (valve types, access) related variables. There were no significant differences in terms of MACCE (log rank p = .550), all-cause mortality (log rank p = .433), strokes (log rank p = .153), and repeat PCI (log rank p = .054) in patients who underwent PCI with/after TAVR when compared to patients who received PCI before TAVR. CONCLUSION: Among patients who underwent both PCI and TAVR, history of CABG, higher BMI, and statin therapy had lower, while those discharged on warfarin, had higher adverse event rates. Adverse events rates were similar regardless of timing of PCI.


Assuntos
Estenose da Valva Aórtica , Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Substituição da Valva Aórtica Transcateter , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Doença da Artéria Coronariana/cirurgia , Doença da Artéria Coronariana/terapia , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Sistema de Registros , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
10.
Catheter Cardiovasc Interv ; 96(7): 1522-1530, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32427426

RESUMO

BACKGROUND: Transcatheter aortic valves are prone to acute recoil similar to the metal-based coronary stents. However, it is not clear if recoil remains a factor only after the initial valve deployment or also after post-dilation. METHODS: We conducted a retrospective observational study of patients who underwent transfemoral transcatheter aortic valve replacement (TAVR) with SAPIEN-3 valve. Acute recoil at the upper, central, and lower levels of the valve was calculated in both anteroposterior right anterior oblique (RAO) and lateral left anterior oblique (LAO) views after initial deployment as well as after post-dilation. The average recoil of the RAO and LAO views was also calculated and described as RAO/LAO. RESULTS: The acute recoil in the RAO/LAO views (mean ± SD) was 3.9 ± 1.1% after valve deployment in the whole study population (n = 257). Among the subset of patients who required post-dilation (n = 133), the mean acute recoil in the RAO/LAO views was found to be greater after initial valve deployment as compared with after post-dilation (3.8 ± 1.1% vs. 3.0 ± 0.9%; p < .001). Further, acute recoil was significantly greater in the RAO view than the LAO view and at the central level of the prosthesis as compared with the upper and lower levels. Those findings were consistent after initial deployment as well as after post-dilation. Clinical outcomes were similar between patients who required post-dilation compared to those who did not. In multivariable logistic regression analysis, only smaller valve cover index was found to be an independent predictor of 30-day mild or greater aortic regurgitation (OR 0.007; 95% CI 0.0001-0.707; p = .035). CONCLUSION: Acute elastic recoil of the SAPIEN-3 valve was significantly less after post-dilation as compared with after deployment. It was also greater when measured in the RAO view as compared with the LAO view. Furthermore, acute recoil was not homogenous across the height of the valve stent frame.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Valvuloplastia com Balão , Cateterismo Periférico , Artéria Femoral , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Valvuloplastia com Balão/efeitos adversos , Cateterismo Periférico/efeitos adversos , Elasticidade , Feminino , Humanos , Masculino , Desenho de Prótese , Estudos Retrospectivos , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
11.
Catheter Cardiovasc Interv ; 96(2): 442-447, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-31713996

RESUMO

INTRODUCTION: Percutaneous femoral access is the preferred access route for transcatheter aortic valve replacement (TAVR). The majority of experienced TAVR centers use two 6F Perclose ProGlide™ devices to close the primary vascular access site, deployed prior to upsizing sheath size with closure completed at the end of the case (the "preclose" approach). A strategy of utilizing a single Perclose device to preclose may have advantages including fewer complications, complexity, and cost, but the safety of this is unknown. This study examines in the safety and efficacy of using a single Perclose versus double Perclose for perclosure of large bore access during TAVR. METHODS: Patients undergoing Transfemoral (TF) TAVR from January 2014 to December 2017 within the Cleveland Clinic Aortic Valve Center were identified. A retrospective review of medical charts was conducted. Vascular complications were defined according to the VARC-2 criteria. RESULTS: A total of 740 patients were included; 487 (65.8%) received a single Perclose device while 253 (34.2%) received double Perclose devices. Baseline characteristics were similar with no differences between the single versus double Perclose groups, respectively. The access sheath size was similar in both groups with (14, 16, and 18 F) being the most common sizes utilized. Of the total 487 patients with single Perclose, 75.6% needed additional closure device (AngioSeal). With double Perclose strategy, additional closure device (AngioSeal) was used in 40.3% patients with 470 (63.5%) patients being successfully perclosed. Vascular complication rates including hematoma, stenosis requiring stenting, pseudoaneurysm, and other major vascular complications were similar between both groups. CONCLUSION: Single 6F ProGlide use for preclosure is a safe strategy for TF TAVR using the S3 valve. Additional closure device was not needed in almost one-quarter of the patients. When necessary, residual bleeding can be controlled with the AngioSeal Device at the end of the procedure. This single device preclose strategy can help to reduce the cost of TAVR procedure without increasing risk.


Assuntos
Cateterismo Periférico , Artéria Femoral , Hemorragia/prevenção & controle , Técnicas Hemostáticas/instrumentação , Substituição da Valva Aórtica Transcateter , Dispositivos de Oclusão Vascular , Idoso , Idoso de 80 Anos ou mais , Cateterismo Periférico/efeitos adversos , Desenho de Equipamento , Feminino , Hemorragia/etiologia , Técnicas Hemostáticas/efeitos adversos , Humanos , Masculino , Ohio , Punções , Estudos Retrospectivos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
12.
Catheter Cardiovasc Interv ; 94(4): 555-561, 2019 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-31429192

RESUMO

OBJECTIVES: Determine the outcomes of polytetrafluoroethylene (PTFE) covered stents for coronary artery perforation (CAP) and coronary artery aneurysm (CAA). BACKGROUND: PTFE covered stents have been used for treatment of potentially life-threatening CAP and CAA. The short and long-term outcomes of the PTFE covered stent for CAP and CAA have not been well studied. METHODS: We performed a retrospective study of PTFE covered stents that were placed in the patients from 2003 to 2017. Short term outcomes included in-hospital mortality, pericardial effusion, cardiac tamponade, and length of stay. Long-term outcomes included target lesion revascularization (TLR), in-stent restenosis (ISR), and long-term mortality. RESULTS: Fifty-three PTFE covered stents were placed in 32 patients of which there were 24 patients with a CAP with a mean age of 75 ± 8 years. Two patients died in-hospital, with no additional deaths at 30 days. The rate of ISR was 25%, with estimated rates of TLR of 2.6% (3 years) and 17.8% (5 years). The median survival was 55.6 months, with survival at 10 years estimated to be 30.9%. Eight patients received a PTFE covered stent for CAA with a mean age of 59 ± 15 years with no in-hospital or 30-day mortality. Median follow-up of 49 months showed no evidence of TLR. The all-cause mortality was 12% at 1 year and 38% at 3 years. CONCLUSIONS: PTFE covered stents is an effective option in patients with CAP and CAA. The long-term outcomes may be related to the pathology of the disease rather than the stent itself.


Assuntos
Aneurisma Coronário/terapia , Vasos Coronários/lesões , Traumatismos Cardíacos/terapia , Intervenção Coronária Percutânea/instrumentação , Politetrafluoretileno , Stents , Idoso , Idoso de 80 Anos ou mais , Aneurisma Coronário/diagnóstico por imagem , Aneurisma Coronário/mortalidade , Aneurisma Coronário/fisiopatologia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/fisiopatologia , Feminino , Traumatismos Cardíacos/diagnóstico por imagem , Traumatismos Cardíacos/mortalidade , Traumatismos Cardíacos/fisiopatologia , Mortalidade Hospitalar , Humanos , Masculino , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
13.
JACC Cardiovasc Interv ; 17(16): 1905-1915, 2024 Aug 26.
Artigo em Inglês | MEDLINE | ID: mdl-39197989

RESUMO

BACKGROUND: Tricuspid regurgitation (TR) is associated with worse clinical outcomes after transcatheter aortic valve replacement (TAVR) and mitral transcatheter edge-to-edge repair (M-TEER), but little is known about its association with health status outcomes. OBJECTIVES: The aims of this study were to explore, using the Society of Thoracic Surgeons and American College of Cardiology TVT (Transcatheter Valve Therapy) Registry, the association between baseline TR and health status after TAVR and M-TEER and to determine if baseline TR was associated with clinical endpoints. METHODS: Health status was assessed using Kansas City Cardiomyopathy Questionnaire overall summary (KCCQ-OS) score in patients enrolled in the TVT Registry who underwent isolated TAVR or M-TEER between January 2019 and June 2021. The association among baseline TR and KCCQ-OS score, being alive and well, and clinical outcomes was examined. RESULTS: In total, 130,097 TAVR patients (13.1% with moderate TR, 2.3% with severe TR) and 19,593 M-TEER patients (33.2% with moderate TR, 14.7% with severe TR) were included. Mean KCCQ-OS scores were lower with severe vs moderate vs none to mild TR at baseline prior to TAVR (39.4 ± 24.2 vs 45.2 ± 24.7 vs 51.3 ± 25.3; P < 0.01) or M-TEER (38.1 ± 23.9 vs 41.9 ± 24.7 vs 45.4 ± 25.2; P < 0.01) and similarly at 30 days and 1 year. The odds of being alive and well at 1 year were lower with moderate or severe TR before TAVR (adjusted OR: 0.79 [95% CI: 0.74-0.85] and adjusted OR: 0.81 [95% CI: 0.70-0.94], respectively) and severe TR before M-TEER (adjusted OR: 0.53; 95% CI: 0.40-0.71). Furthermore, moderate or severe TR before TAVR was associated with higher 1-year mortality and readmission, whereas moderate or severe TR before M-TEER was associated with higher 1-year mortality. CONCLUSIONS: In a large cohort of U.S. patients who underwent TAVR or M-TEER, greater baseline TR was associated with worse health status and clinical outcomes. Understanding adverse outcomes of TR in patients with coexisting valvular abnormalities is important, especially with rapidly evolving transcatheter tricuspid valve interventions.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Nível de Saúde , Valva Mitral , Sistema de Registros , Substituição da Valva Aórtica Transcateter , Insuficiência da Valva Tricúspide , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Feminino , Masculino , Resultado do Tratamento , Insuficiência da Valva Tricúspide/fisiopatologia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/mortalidade , Insuficiência da Valva Tricúspide/cirurgia , Idoso , Fatores de Tempo , Idoso de 80 Anos ou mais , Fatores de Risco , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Valva Mitral/cirurgia , Valva Mitral/fisiopatologia , Valva Mitral/diagnóstico por imagem , Estados Unidos , Medição de Risco , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/mortalidade , Índice de Gravidade de Doença , Recuperação de Função Fisiológica , Valva Tricúspide/fisiopatologia , Valva Tricúspide/cirurgia , Valva Tricúspide/diagnóstico por imagem , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/mortalidade
14.
Circ Cardiovasc Interv ; 17(9): e014055, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38836574

RESUMO

BACKGROUND: Increased left atrial pressure (LAP) has been associated with adverse outcomes after mitral transcatheter edge-to-edge repair (M-TEER). We sought to evaluate outcomes based on differences in postprocedural LAP measured after the final clip deployment. METHODS: We included consecutive patients who underwent M-TEER at our institution between 2014 and 2022 with LAP monitoring. Patients were stratified into 3 groups according to tertiles of post-TEER mean LAP. Outcomes were assessed using Kaplan-Meier analysis and Cox proportional hazards models. RESULTS: We included 273 patients (mean age, 76.8±10.8 years; 42.5% women; 78.4% White). The mean post-TEER LAP was 8.7±1.7 mm Hg in tertile 1 (n=85), 14.4±1.6 mm Hg in tertile 2 (n=95), and 21.9±3.8 mm Hg in tertile 3 (n=93). In comparison with tertile 1, both tertiles 2 and 3 were associated with increased risk of all-cause mortality or heart failure hospitalization at 2 years (adjusted hazard ratio [adjHR], 2.27 [95% CI, 1.25-4.12] and adjHR, 3.00 [95% CI, 1.59-5.64], respectively). Among patients with primary mitral regurgitation, higher LAP was associated with increased risk of 2-year all-cause mortality or heart failure hospitalization (tertile 2 versus 1: adjHR, 3.00 [95% CI, 1.37-6.56]; tertile 3 versus 1: adjHR, 5.52 [95% CI, 2.04-14.95]). However, in patients with secondary mitral regurgitation, neither being in tertile 2 (adjHR, 1.53 [95% CI, 0.55-4.24]) nor tertile 3 (adjHR, 2.18 [95% CI, 0.82-5.77]) were associated with the composite outcome compared with tertile 1. Any degree of LAP reduction following M-TEER was associated with lower mortality or heart failure hospitalization compared with no LAP reduction (adjHR, 0.59 [95% CI, 0.39-0.88]). CONCLUSIONS: Elevated LAP after M-TEER was associated with increased 2-year risk of mortality or heart failure hospitalization. Exploration of reasons for elevated LAP after M-TEER and ways to lower it warrant further investigation.


Assuntos
Função do Átrio Esquerdo , Pressão Atrial , Cateterismo Cardíaco , Insuficiência da Valva Mitral , Valva Mitral , Humanos , Feminino , Masculino , Idoso , Insuficiência da Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/mortalidade , Insuficiência da Valva Mitral/diagnóstico por imagem , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/mortalidade , Valva Mitral/fisiopatologia , Valva Mitral/cirurgia , Valva Mitral/diagnóstico por imagem , Resultado do Tratamento , Fatores de Risco , Idoso de 80 Anos ou mais , Fatores de Tempo , Estudos Retrospectivos , Medição de Risco , Recuperação de Função Fisiológica
15.
Methodist Debakey Cardiovasc J ; 19(1): 32-37, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37064497

RESUMO

A 62-year-old male presented to the emergency department with acute viral bronchitis and worsening of his chronic dyspnea on exertion. Incidentally, a murmur was detected on physical examination. Extensive work-up, including coronary computed tomography angiography, revealed a rare combination and potential association between severe bicuspid aortic valve stenosis and coronary-pulmonary artery fistulas.


Assuntos
Estenose da Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Doença da Artéria Coronariana , Fístula , Cardiopatias Congênitas , Masculino , Humanos , Pessoa de Meia-Idade , Artéria Pulmonar/diagnóstico por imagem , Constrição Patológica , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico por imagem , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia
16.
Am J Cardiol ; 197: 24-33, 2023 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-37137251

RESUMO

Data regarding the impact of pacing on outcomes after transcatheter aortic valve implantation (TAVI) is evolving especially with regards to pre-existing permanent pacemaker (PPM). We examined the impact of new and previous PPM on the clinical and hemodynamic outcomes after SAPIEN-3 TAVI. We included all consecutive patients who underwent transfemoral TAVI using SAPIEN-3 valve from 2015 to 2018 at our institution. Among 1,028 patients, 10.2% required a new PPM within 30 days, whereas 14% had a pre-existing PPM. The presence of either previous or new PPM had no impact on the 3-year mortality (log-rank p = 0.6) or 1-year major adverse cardiac and cerebrovascular events (log-rank p = 0.65). New PPM was associated with lower left ventricular (LV) ejection fraction (LVEF) at both 30 days (54.4 ± 11.3% vs 58.4 ± 10.1%, p = 0.001) and 1 year (54.2 ± 12% vs 59.1 ± 9.9%, p = 0.009) than no PPM. Similarly, previous PPM was associated with worse LVEF at 30 days (53.6 ± 12.3%, p <0.001) and 1 year (55.5 ± 12.1%, p = 0.006) than no PPM. Interestingly, new PPM was associated with lower 1-year mean gradient (11.4 ± 3.8 vs 12.6 ± 5.6 mm Hg, p = 0.04) and peak gradient (21.3 ± 6.5 vs 24.1 ± 10.4 mm Hg, p = 0.01), despite no baseline differences. Previous PPM was also associated with lower 1-year mean gradient (10.3 ± 4.4 mm Hg, p = 0.001) and peak gradient (19.4 ± 8 mm Hg, p <0.001) and higher Doppler velocity index (0.51 ± 0.12 vs 0.47 ± 0.13, p = 0.039). Moreover, 1-year LV end-systolic volume index was higher with new (23.2 ± 16.1 vs 20 ± 10.8 ml/m2, p = 0.038) and previous PPM (24.5 ± 19.7, p = 0.038) than no PPM. Previous PPM was associated with higher moderate-to-severe tricuspid regurgitation (35.3% vs 17.7%, p <0.001). There were no differences regarding the rest of the studied echocardiographic outcomes at 1 year. In conclusion, new and previous PPM did not affect 3-year mortality or 1-year major adverse cardiac and cerebrovascular events; however, they were associated with worse LVEF, higher 1-year LV end-systolic volume index, and lower mean and peak gradients on follow-up than no PPM.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Estenose da Valva Aórtica/complicações , Ecocardiografia , Função Ventricular Esquerda , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia
17.
Am Heart J Plus ; 27: 100265, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36779177

RESUMO

Background: Elevated cardiac troponin (cTn) levels in patients with COVID-19 has been associated with worse outcomes. Guidelines on best practices of those patients remain uncertain. Methods: We included patients with COVID-19 and cTn above the assay-specific upper limit of normal (ULN) enrolled in the American Heart Association's COVID-19 registry between March 2020-January 2021. Site-level variability in invasive coronary angiography, LVEF assessment, ICU utilization, and inpatient mortality were determined by calculating adjusted median odds ratio (MOR) using hierarchical logistic regression models. Temporal trends were assessed with Cochran-Armitage trend test. Results: Among 32,636 patients, we included 6234 (19.4 %) with cTn above ULN (age 68.7 ± 16.0 years, 56.5 % male, 51.5 % Caucasian), of whom 1365 (21.6 %) had ≥5-fold elevations. Across 55 sites, the median rate of invasive coronary angiography was 0.1 % with adjusted MOR 1.5(1.0,2.3), median LVEF assessment was 25.5 %, MOR 3.0(2.2,3.9), ICU utilization was 41.7 %, MOR 2.2(1.8,2.6), and mortality was 20.9 %, MOR 1.7(1.5,2.0). Over time, we noted a significant increase in invasive coronary angiography (p-trend = 0.001), and LVEF assessment (p-trend<0.001), and reduction in mortality (p-trend<0.001), without significant change in ICU admissions (p-trend = 0.08). Similar variability and temporal trends were seen among patients with ≥5-fold cTn elevation. Conclusions: The use of invasive coronary angiography among patients with COVID-19 and myocardial injury was very low during the early pandemic. We found moderate institutional variability in processes of care with an uptrend in invasive catheterization and LVEF assessment, and downtrend in mortality. Comparative effectiveness studies are needed to examine whether variability in care is associated with differences in outcomes.

18.
Am J Cardiol ; 192: 174-181, 2023 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-36812701

RESUMO

The COVID-19 pandemic accelerated adaption of a telehealth care model. We studied the impact of telehealth on the management of atrial fibrillation (AF) by electrophysiology providers in a large, multisite clinic. Clinical outcomes, quality metrics, and indicators of clinical activity for patients with AF during the 10-week period of March 22, 2020 to May 30, 2020 were compared with those from the 10-week period of March 24, 2019 to June 1, 2019. There were 1946 unique patient visits for AF (1,040 in 2020 and 906 in 2019). During 120 days after each encounter, there was no difference in hospital admissions (11.7% vs 13.5%, p = 0.25) or emergency department visits (10.4% vs 12.5%, p = 0.15) in 2020 compared with 2019. There was a total of 31 deaths within 120 days, with similar rates in 2020 and 2019 (1.8% vs 1.3%, p = 0.38). There was no significant difference in quality metrics. The following clinical activities occurred less frequently in 2020 than in 2019: offering escalation of rhythm control (16.3% vs 23.3%, p <0.001), ambulatory monitoring (29.7% vs 51.7%, p <0.001), and electrocardiogram review for patients on antiarrhythmic drug therapy (22.1% vs 90.2%, p <0.001). Discussions about risk factor modification were more frequent in 2020 compared with 2019 (87.9% vs 74.8%, p <0.001). In conclusion, the use of telehealth in the outpatient management of AF was associated with similar clinical outcomes and quality metrics but differences in clinical activity compared with traditional ambulatory encounters. Longer-term outcomes warrant further investigation.


Assuntos
Fibrilação Atrial , COVID-19 , Telemedicina , Humanos , Fibrilação Atrial/tratamento farmacológico , Pacientes Ambulatoriais , Pandemias
19.
J Leukoc Biol ; 112(3): 449-456, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35137444

RESUMO

Few cytokines/growth modulating proteins are known to be chemoattractants for hematopoietic stem (HSC) and progenitor cells (HPC); stromal cell-derived factor 1α (SDF1α/CXCL12) being the most potent known such protein. DEK, a nuclear DNA-binding chromatin protein with hematopoietic cytokine-like activity, is a chemotactic factor attracting mature immune cells. Transwell migration assays were performed to test whether DEK serves as a chemotactic agent for HSC/HPC. DEK induced dose- and time-dependent directed migration of lineage negative (Lin- ) Sca-1+ c-Kit+ (LSK) bone marrow (BM) cells, HSCs and HPCs. Checkerboard assays demonstrated that DEK's activity was chemotactic (directed), not chemokinetic (random migration), in nature. DEK and SDF1α compete for HSC/HPC chemotaxis. Blocking CXCR2 with neutralizing antibodies or inhibiting Gαi protein signaling with Pertussis toxin pretreatment inhibited migration of LSK cells toward DEK. Thus, DEK is a novel and rare chemotactic agent for HSC/HPC acting in a direct or indirect CXCR2 and Gαi protein-coupled signaling-dependent manner.


Assuntos
Células-Tronco Hematopoéticas , Proteínas Nucleares , Células da Medula Óssea/metabolismo , Quimiotaxia , Proteínas de Ligação a DNA/metabolismo , Células-Tronco Hematopoéticas/metabolismo , Proteínas Nucleares/metabolismo , Receptores de Interleucina-8B/metabolismo
20.
Transplant Proc ; 54(3): 663-670, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35256200

RESUMO

BACKGROUND: Cardiovascular disease is the most common cause of death among kidney transplant (KT) recipients. Trials routinely exclude patients with end-stage renal disease when assessing the effect of coronary artery revascularization. We looked to compare long-term outcomes in patients who underwent percutaneous coronary intervention (PCI) before KT with those managed medically. METHODS: We identified all patients who underwent coronary artery catheterization before KT from January 2008 to November 2019 at the Cleveland Clinic. The primary endpoint was all-cause mortality. RESULTS: A total of 272 patients were included, of whom 52 (19.11%) underwent PCI, and the remaining 220 patients were managed medically. The median age in the PCI group was 57.4 years (interquartile range [IQR], 46.9-61.2 years), whereas it was 53.9 years (IQR, 44.6-61 years) in the group medically managed. Baseline characteristics including sex, race, hypertension, diabetes, smoking, and hyperlipidemia were comparable in both groups. The median time to KT was 2.4 years (IQR, 1-5 years) in the PCI group vs 1.2 years (IQR, 0.6-3.3 years) in the medically managed group (P = .001). Among patients who underwent PCI, 40.4% had single vessel disease and 59.6% had multivessel disease compared with 16.8% and 28.6%, respectively, in the medically managed group (P < .001). Overall, there was no difference in mortality in the PCI group compared with the medically managed group after 10 years of follow-up (P = .416). CONCLUSIONS: Patients with coronary artery disease can be safely treated with PCI before KT and have comparable outcomes to those who are managed medically.


Assuntos
Doença da Artéria Coronariana , Transplante de Rim , Intervenção Coronária Percutânea , Ponte de Artéria Coronária/efeitos adversos , Doença da Artéria Coronariana/etiologia , Humanos , Transplante de Rim/efeitos adversos , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Fatores de Risco , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa