Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 378
Filtrar
Mais filtros

País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Eur Radiol ; 34(4): 2699-2710, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37823922

RESUMO

OBJECTIVES: MRI-derived extracellular volume (ECV) allows characterization of myocardial changes before the onset of overt pathology, which may be caused by cancer therapy cardiotoxicity. Our purpose was to review studies exploring the role of MRI-derived ECV as an early cardiotoxicity biomarker to guide timely intervention. MATERIALS AND METHODS: In April 2022, we performed a systematic search on EMBASE and PubMed for articles on MRI-derived ECV as a biomarker of cancer therapy cardiotoxicity. Two blinded researchers screened the retrieved articles, including those reporting ECV values at least 3 months from cardiotoxic treatment. Data extraction was performed for each article, including clinical and technical data, and ECV values. Pooled ECV was calculated using the random effects model and compared among different treatment regimens and among those who did or did not experience overt cardiac dysfunction. Meta-regression analyses were conducted to appraise which clinical or technical variables yielded a significant impact on ECV. RESULTS: Overall, 19 studies were included. Study populations ranged from 9 to 236 patients, for a total of 1123 individuals, with an average age ranging from 12.5 to 74 years. Most studies included patients with breast or esophageal cancer, treated with anthracyclines and chest radiotherapy. Pooled ECV was 28.44% (95% confidence interval, CI, 26.85-30.03%) among subjects who had undergone cardiotoxic cancer therapy, versus 25.23% (95%CI 23.31-27.14%) among those who had not (p = .003). CONCLUSION: A higher ECV in patients who underwent cardiotoxic treatment could imply subclinical changes in the myocardium, present even before overt cardiac pathology is detectable. CLINICAL RELEVANCE STATEMENT: The ability to detect subclinical changes in the myocardium displayed by ECV suggests its use as an early biomarker of cancer therapy-related cardiotoxicity. KEY POINTS: • Cardiotoxicity is a common adverse effect of cancer therapy; therefore, its prompt detection could improve patient outcomes. • Pooled MRI-derived myocardial extracellular volume was higher in patients who underwent cardiotoxic cancer therapy than in those who did not (28.44% versus 25.23%, p = .003). • MRI-derived myocardial extracellular volume represents a potential early biomarker of cancer therapy cardiotoxicity.


Assuntos
Cardiotoxicidade , Neoplasias , Humanos , Criança , Adolescente , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Idoso , Cardiotoxicidade/diagnóstico por imagem , Cardiotoxicidade/etiologia , Cardiotoxicidade/patologia , Imageamento por Ressonância Magnética , Miocárdio/patologia , Biomarcadores , Neoplasias/diagnóstico por imagem , Neoplasias/tratamento farmacológico , Neoplasias/patologia , Imagem Cinética por Ressonância Magnética , Valor Preditivo dos Testes
2.
Radiol Med ; 2024 Jul 26.
Artigo em Inglês | MEDLINE | ID: mdl-39060886

RESUMO

PURPOSE: To evaluate if background parenchymal enhancement (BPE) on contrast-enhanced mammography (CEM), graded according to the 2022 CEM-dedicated Breast Imaging Reporting and Data System (BI-RADS) lexicon, is associated with breast density, menopausal status, and age. METHODS: This bicentric retrospective analysis included CEM examinations performed for the work-up of suspicious mammographic findings. Three readers independently and blindly evaluated BPE on recombined CEM images and breast density on low-energy CEM images. Inter-reader reliability was estimated using Fleiss κ. Multivariable binary logistic regression was performed, dichotomising breast density and BPE as low (a/b BI-RADS categories, minimal/mild BPE) and high (c/d BI-RADS categories, moderate/marked BPE). RESULTS: A total of 200 women (median age 56.8 years, interquartile range 50.5-65.6, 140/200 in menopause) were included. Breast density was classified as a in 27/200 patients (13.5%), as b in 110/200 (55.0%), as c in 52/200 (26.0%), and as d in 11/200 (5.5%), with moderate inter-reader reliability (κ = 0.536; 95% confidence interval [CI] 0.482-0.590). BPE was minimal in 95/200 patients (47.5%), mild in 64/200 (32.0%), moderate in 25/200 (12.5%), marked in 16/200 (8.0%), with substantial inter-reader reliability (κ = 0.634; 95% CI 0.581-0.686). At multivariable logistic regression, premenopausal status and breast density were significant positive predictors of high BPE, with adjusted odds ratios of 6.120 (95% CI 1.847-20.281, p = 0.003) and 2.416 (95% CI 1.095-5.332, p = 0.029) respectively. CONCLUSION: BPE on CEM is associated with well-established breast cancer risk factors, being higher in women with higher breast density and premenopausal status.

3.
Radiol Med ; 2024 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-39162940

RESUMO

PURPOSE: This study aimed to determine the accuracy of detecting ischemic core volume using computed tomography perfusion (CTP) in patients with suspected acute ischemic stroke compared to diffusion-weighted magnetic resonance imaging (DW-MRI) as the reference standard. METHODS: This retrospective monocentric study included patients who underwent CTP and DW-MRI for suspected acute ischemic stroke. The ischemic core size was measured at DW-MRI. The detectability threshold volume was defined as the lowest volume detected by each method. Clinical data on revascularization therapy, along with the clinical decision that influenced the choice, were collected. Volumes of the ischemic cores were compared using the Mann-Whitney U test. RESULTS: Of 83 patients who underwent CTP, 52 patients (median age 73 years, IQR 63-80, 36 men) also had DW-MRI and were included, with a total of 70 ischemic cores. Regarding ischemic cores, only 18/70 (26%) were detected by both CTP and DW-MRI, while 52/70 (74%) were detected only by DW-MRI. The median volume of the 52 ischemic cores undetected on CTP (0.6 mL, IQR 0.2-1.3 mL) was significantly lower (p < 0.001) than that of the 18 ischemic cores detected on CTP (14.2 mL, IQR 7.0-18.4 mL). The smallest ischemic core detected on CTP had a volume of 5.0 mL. Among the 20 patients with undetected ischemic core on CTP, only 10% (2/20) received thrombolysis treatment. CONCLUSIONS: CTP maps failed in detecting ischemic cores smaller than 5 mL. DW-MRI remains essential for suspected small ischemic brain lesions to guide a correct treatment decision-making.

4.
Radiol Med ; 2024 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-39162938

RESUMO

PURPOSE: This study quantifies the impact on budget and cost per health benefit of implementing digital breast tomosynthesis (DBT) in place of digital mammography (DM) for breast cancer screening among asymptomatic women in Italy. METHODS: A budget impact analysis and a cost consequence analysis were conducted using parameters from the MAITA project and literature. The study considered four scenarios for DBT implementation, i.e., DBT for all women, DBT for women aged 45-49 years, DBT based on breast density (BI-RADS C + D or D only), and compared these to the current DM screening. Healthcare provider's perspective was adopted, including screening, diagnosis, and cancer treatment costs. RESULTS: Introducing DBT for all women would increase overall screening costs by 20%. Targeting DBT to women aged 45-49 years or with dense breasts would result in smaller cost increases (3.2% for age-based and 1.4-10.7% for density-based scenarios). The cost per avoided interval cancer was significantly higher when DBT was applied to all women compared to targeted approaches. The cost per gained early-detected cancer slightly increases in targeted approaches, while the assumptions on the clinical significance and overdiagnosis of cancers detected by DBT and not by DM have a strong impact. CONCLUSIONS: Implementing DBT as a primary breast cancer test in screening programs in Italy would lead to a substantial increase in costs. Tailoring DBT use to women aged 45-49 or with dense breasts could enhance the feasibility and sustainability of the intervention. Further research is needed to clarify the impact of DBT on overdiagnosis and the long-term outcomes.

5.
Radiol Med ; 129(8): 1156-1172, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39042203

RESUMO

PURPOSE: We present a comprehensive investigation into the organizational, social, and ethical impact of implementing digital breast tomosynthesis (DBT) as a primary test for breast cancer screening in Italy. The analyses aimed to assess the feasibility of DBT specifically for all women aged 45-74, women aged 45-49 only, or those with dense breasts only. METHODS: Questions were framed according to the European Network of Health Technology Assessment (EuNetHTA) Screening Core Model to produce evidence for the resources, equity, acceptability, and feasibility domains of the Grading of Recommendations Assessment, Development and Evaluation (GRADE) decision framework. The study integrated evidence from the literature, the MAITA DBT trials, and Italian pilot programs. Structured interviews, surveys, and systematic reviews were conducted to gather data on organizational impact, acceptability among women, reading and acquisition times, and the technical requirements of DBT in screening. RESULTS: Implementing DBT could significantly affect the screening program, primarily due to increased reading times and the need for additional human resources (radiologists and radiographers). Participation rates in DBT screening were similar, if not better, to those observed with standard digital mammography, indicating good acceptability among women. The study also highlighted the necessity for specific training for radiographers. The interviewed key persons unanimously considered feasible tailored screening strategies based on breast density or age, but they require effective communication with the target population. CONCLUSIONS: An increase in radiologists' and radiographers' workload limits the feasibility of DBT screening. Tailored screening strategies may maximize the benefits of DBT while mitigating potential challenges.


Assuntos
Neoplasias da Mama , Detecção Precoce de Câncer , Mamografia , Humanos , Feminino , Neoplasias da Mama/diagnóstico por imagem , Itália , Mamografia/métodos , Pessoa de Meia-Idade , Idoso , Detecção Precoce de Câncer/métodos , Estudos de Viabilidade
6.
Eur Radiol ; 33(10): 6746-6755, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37160426

RESUMO

OBJECTIVE: Breast arterial calcifications (BAC) are a sex-specific cardiovascular disease biomarker that might improve cardiovascular risk stratification in women. We implemented a deep convolutional neural network for automatic BAC detection and quantification. METHODS: In this retrospective study, four readers labelled four-view mammograms as BAC positive (BAC+) or BAC negative (BAC-) at image level. Starting from a pretrained VGG16 model, we trained a convolutional neural network to discriminate BAC+ and BAC- mammograms. Accuracy, F1 score, and area under the receiver operating characteristic curve (AUC-ROC) were used to assess the diagnostic performance. Predictions of calcified areas were generated using the generalized gradient-weighted class activation mapping (Grad-CAM++) method, and their correlation with manual measurement of BAC length in a subset of cases was assessed using Spearman ρ. RESULTS: A total 1493 women (198 BAC+) with a median age of 59 years (interquartile range 52-68) were included and partitioned in a training set of 410 cases (1640 views, 398 BAC+), validation set of 222 cases (888 views, 89 BAC+), and test set of 229 cases (916 views, 94 BAC+). The accuracy, F1 score, and AUC-ROC were 0.94, 0.86, and 0.98 in the training set; 0.96, 0.74, and 0.96 in the validation set; and 0.97, 0.80, and 0.95 in the test set, respectively. In 112 analyzed views, the Grad-CAM++ predictions displayed a strong correlation with BAC measured length (ρ = 0.88, p < 0.001). CONCLUSION: Our model showed promising performances in BAC detection and in quantification of BAC burden, showing a strong correlation with manual measurements. CLINICAL RELEVANCE STATEMENT: Integrating our model to clinical practice could improve BAC reporting without increasing clinical workload, facilitating large-scale studies on the impact of BAC as a biomarker of cardiovascular risk, raising awareness on women's cardiovascular health, and leveraging mammographic screening. KEY POINTS: • We implemented a deep convolutional neural network (CNN) for BAC detection and quantification. • Our CNN had an area under the receiving operator curve of 0.95 for BAC detection in the test set composed of 916 views, 94 of which were BAC+ . • Furthermore, our CNN showed a strong correlation with manual BAC measurements (ρ = 0.88) in a set of 112 views.


Assuntos
Doenças Mamárias , Doenças Cardiovasculares , Aprendizado Profundo , Feminino , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos , Mamografia/métodos , Doenças Mamárias/diagnóstico por imagem
7.
Eur Radiol ; 33(9): 6213-6225, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37138190

RESUMO

OBJECTIVES: To report mastectomy and reoperation rates in women who had breast MRI for screening (S-MRI subgroup) or diagnostic (D-MRI subgroup) purposes, using multivariable analysis for investigating the role of MRI referral/nonreferral and other covariates in driving surgical outcomes. METHODS: The MIPA observational study enrolled women aged 18-80 years with newly diagnosed breast cancer destined to have surgery as the primary treatment, in 27 centres worldwide. Mastectomy and reoperation rates were compared using non-parametric tests and multivariable analysis. RESULTS: A total of 5828 patients entered analysis, 2763 (47.4%) did not undergo MRI (noMRI subgroup) and 3065 underwent MRI (52.6%); of the latter, 2441/3065 (79.7%) underwent MRI with preoperative intent (P-MRI subgroup), 510/3065 (16.6%) D-MRI, and 114/3065 S-MRI (3.7%). The reoperation rate was 10.5% for S-MRI, 8.2% for D-MRI, and 8.5% for P-MRI, while it was 11.7% for noMRI (p ≤ 0.023 for comparisons with D-MRI and P-MRI). The overall mastectomy rate (first-line mastectomy plus conversions from conserving surgery to mastectomy) was 39.5% for S-MRI, 36.2% for P-MRI, 24.1% for D-MRI, and 18.0% for noMRI. At multivariable analysis, using noMRI as reference, the odds ratios for overall mastectomy were 2.4 (p < 0.001) for S-MRI, 1.0 (p = 0.957) for D-MRI, and 1.9 (p < 0.001) for P-MRI. CONCLUSIONS: Patients from the D-MRI subgroup had the lowest overall mastectomy rate (24.1%) among MRI subgroups and the lowest reoperation rate (8.2%) together with P-MRI (8.5%). This analysis offers an insight into how the initial indication for MRI affects the subsequent surgical treatment of breast cancer. KEY POINTS: • Of 3065 breast MRI examinations, 79.7% were performed with preoperative intent (P-MRI), 16.6% were diagnostic (D-MRI), and 3.7% were screening (S-MRI) examinations. • The D-MRI subgroup had the lowest mastectomy rate (24.1%) among MRI subgroups and the lowest reoperation rate (8.2%) together with P-MRI (8.5%). • The S-MRI subgroup had the highest mastectomy rate (39.5%) which aligns with higher-than-average risk in this subgroup, with a reoperation rate (10.5%) not significantly different to that of all other subgroups.


Assuntos
Neoplasias da Mama , Feminino , Humanos , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/cirurgia , Mastectomia , Mastectomia Segmentar , Mama , Imageamento por Ressonância Magnética , Cuidados Pré-Operatórios
8.
Eur Radiol ; 2023 Nov 24.
Artigo em Inglês | MEDLINE | ID: mdl-37999727

RESUMO

OBJECTIVES: To investigate the influence of preoperative breast MRI on mastectomy and reoperation rates in patients with pure ductal carcinoma in situ (DCIS). METHODS: The MIPA observational study database (7245 patients) was searched for patients aged 18-80 years with pure unilateral DCIS diagnosed at core needle or vacuum-assisted biopsy (CNB/VAB) and planned for primary surgery. Patients who underwent preoperative MRI (MRI group) were matched (1:1) to those who did not receive MRI (noMRI group) according to 8 confounding covariates that drive referral to MRI (age; hormonal status; familial risk; posterior-to-nipple diameter; BI-RADS category; lesion diameter; lesion presentation; surgical planning at conventional imaging). Surgical outcomes were compared between the matched groups with nonparametric statistics after calculating odds ratios (ORs). RESULTS: Of 1005 women with pure unilateral DCIS at CNB/VAB (507 MRI group, 498 noMRI group), 309 remained in each group after matching. First-line mastectomy rate in the MRI group was 20.1% (62/309 patients, OR 2.03) compared to 11.0% in the noMRI group (34/309 patients, p = 0.003). The reoperation rate was 10.0% in the MRI group (31/309, OR for reoperation 0.40) and 22.0% in the noMRI group (68/309, p < 0.001), with a 2.53 OR of avoiding reoperation in the MRI group. The overall mastectomy rate was 23.3% in the MRI group (72/309, OR 1.40) and 17.8% in the noMRI group (55/309, p = 0.111). CONCLUSIONS: Compared to those going directly to surgery, patients with pure DCIS at CNB/VAB who underwent preoperative MRI had a higher OR for first-line mastectomy but a substantially lower OR for reoperation. CLINICAL RELEVANCE STATEMENT: When confounding factors behind MRI referral are accounted for in the comparison of patients with CNB/VAB-diagnosed pure unilateral DCIS, preoperative MRI yields a reduction of reoperations that is more than twice as high as the increase in overall mastectomies. KEY POINTS: • Confounding factors cause imbalance when investigating the influence of preoperative MRI on surgical outcomes of pure DCIS. • When patient matching is applied to women with pure unilateral DCIS, reoperation rates are significantly reduced in women who underwent preoperative MRI. • The reduction of reoperations brought about by preoperative MRI is more than double the increase in overall mastectomies.

9.
Int J Legal Med ; 137(4): 1051-1057, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37046051

RESUMO

In forensic toxicology, when conventional matrices are no longer available, alternative matrices can be used to assess toxicological investigations. Clothes worn by skeletal remains may be a good unconventional matrix for toxicological analyses considering that they have absorbed decomposition fluids and blood from a body. We hypothesized a scenario in which a skeleton, wearing clothes, was discovered in an open environment. From this starting point, an experimental study was developed on different textiles (cotton, wool, and polyester) to evaluate whether water-related atmospheric agents and molecule solubility can largely influence the detection of molecules of toxicological interest on this specific matrix, together with the characteristics of different garments chosen. The experimental study was performed on blood spots, previously spiked with 6-monoacetylmorphine and morphine, accurately placed on different textiles and washed with different quantities of deionized water adjusted at pH 5.6 with formic acid to simulate different rainfall conditions. Toxicological analyses were performed via Solid-Phase Extraction and High-Performance Liquid Chromatography-Tandem Mass Spectrometry analyses (Thermo Scientific™ TSQ Fortis™ II Triple-Quadrupole Mass Spectrometer). From the experimental study morphine could not be detected on 100% cotton and 100% wool fabric after the passing of 500 mL of deionized water and in 100% synthetic polyester textile after washing with 250 mL of deionized water. In conclusion, when toxicological analyses are carried out on unconventional matrices as textiles worn by corpses exposed to different environmental conditions, it is of great importance, in using such substrates as evidence for the presence of molecules of toxicological interest, to evaluate chemical-physical characteristics of each analyte under investigation in order to correctly interpret the toxicological data obtained.


Assuntos
Restos Mortais , Têxteis , Humanos , Animais , Solubilidade , Morfina , Poliésteres , Vestuário
10.
Radiol Med ; 128(2): 133-135, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36586083

RESUMO

We are currently facing extraordinary changes. A harder and harder competition in the field of science is open in each country as well as in continents and worldwide. In this context, what should we teach to young students and doctors? There is a need to look backward and return to "fundamentals", i.e. the deep characteristics that must characterize the research in every field, even in radiology. In this article, we focus on data integrity (including the "declarations" given by the authors who submit a manuscript), reproducibility of study results, and the peer-review process. In addition, we highlight the need of raising the level of evidence of radiological research from the estimation of diagnostic performance to that of diagnostic impact, therapeutic impact, patient outcome, and social impact. Finally, on the emerging topic of radiomics and artificial intelligence, the recommendation is to aim for cross-fertilization with data scientists, possibly involving them in the clinical departments.


Assuntos
Inteligência Artificial , Radiologia , Humanos , Reprodutibilidade dos Testes , Radiografia , Fertilização
11.
Radiology ; 302(3): 568-581, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34904875

RESUMO

Background Contrast-enhanced mammography (CEM) is a promising technique for breast cancer detection, but conflicting results have been reported in previous meta-analyses. Purpose To perform a systematic review and meta-analysis of CEM diagnostic performance considering different interpretation methods and clinical settings. Materials and Methods The MEDLINE, EMBASE, Web of Science, and Cochrane Library databases were systematically searched up to July 15, 2021. Prospective and retrospective studies evaluating CEM diagnostic performance with histopathology and/or follow-up as the reference standard were included. Study quality was assessed with the Quality Assessment of Diagnostic Accuracy Studies 2 tool. Summary diagnostic odds ratio and area under the receiver operating characteristic curve were estimated with the hierarchical summary receiver operating characteristic (HSROC) model. Summary estimates of sensitivity and specificity were obtained with the hierarchical bivariate model, pooling studies with the same image interpretation approach or focused on the same findings. Heterogeneity was investigated through meta-regression and subgroup analysis. Results Sixty studies (67 study parts, 11 049 CEM examinations in 10 605 patients) were included. The overall area under the HSROC curve was 0.94 (95% CI: 0.91, 0.96). Pooled diagnostic odds ratio was 55.7 (95% CI: 42.7, 72.7) with high heterogeneity (τ2 = 0.3). At meta-regression, CEM interpretation with both low-energy and recombined images had higher sensitivity (95% vs 94%, P < .001) and specificity (81% vs 71%, P = .03) compared with recombined images alone. At subgroup analysis, CEM showed a 95% pooled sensitivity (95% CI: 92, 97) and a 78% pooled specificity (95% CI: 66, 87) from nine studies in patients with dense breasts, while in 10 studies on mammography-detected suspicious findings, CEM had a 92% pooled sensitivity (95% CI: 89, 94) and an 84% pooled specificity (95% CI: 73, 91). Conclusion Contrast-enhanced mammography demonstrated high performance in breast cancer detection, especially with joint interpretation of low-energy and recombined images. © RSNA, 2021 Online supplemental material is available for this article. See also the editorial by Bahl in this issue.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Meios de Contraste , Mamografia/métodos , Feminino , Humanos
12.
Eur J Nucl Med Mol Imaging ; 49(9): 3119-3128, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35194673

RESUMO

PURPOSE: To evaluate the diagnostic accuracy of a deep learning (DL) algorithm predicting hemodynamically significant coronary artery disease (CAD) by using a rest dataset of myocardial computed tomography perfusion (CTP) as compared to invasive evaluation. METHODS: One hundred and twelve consecutive symptomatic patients scheduled for clinically indicated invasive coronary angiography (ICA) underwent CCTA plus static stress CTP and ICA with invasive fractional flow reserve (FFR) for stenoses ranging between 30 and 80%. Subsequently, a DL algorithm for the prediction of significant CAD by using the rest dataset (CTP-DLrest) and stress dataset (CTP-DLstress) was developed. The diagnostic accuracy for identification of significant CAD using CCTA, CCTA + CTP stress, CCTA + CTP-DLrest, and CCTA + CTP-DLstress was measured and compared. The time of analysis for CTP stress, CTP-DLrest, and CTP-DLStress was recorded. RESULTS: Patient-specific sensitivity, specificity, NPV, PPV, accuracy, and area under the curve (AUC) of CCTA alone and CCTA + CTPStress were 100%, 33%, 100%, 54%, 63%, 67% and 86%, 89%, 89%, 86%, 88%, 87%, respectively. Patient-specific sensitivity, specificity, NPV, PPV, accuracy, and AUC of CCTA + DLrest and CCTA + DLstress were 100%, 72%, 100%, 74%, 84%, 96% and 93%, 83%, 94%, 81%, 88%, 98%, respectively. All CCTA + CTP stress, CCTA + CTP-DLRest, and CCTA + CTP-DLStress significantly improved detection of hemodynamically significant CAD compared to CCTA alone (p < 0.01). Time of CTP-DL was significantly lower as compared to human analysis (39.2 ± 3.2 vs. 379.6 ± 68.0 s, p < 0.001). CONCLUSION: Evaluation of myocardial ischemia using a DL approach on rest CTP datasets is feasible and accurate. This approach may be a useful gatekeeper prior to CTP stress..


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Aprendizado Profundo , Reserva Fracionada de Fluxo Miocárdico , Imagem de Perfusão do Miocárdio , Humanos , Angiografia por Tomografia Computadorizada , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Imagem de Perfusão do Miocárdio/métodos , Perfusão , Valor Preditivo dos Testes
13.
Eur Radiol ; 32(11): 7388-7399, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35648209

RESUMO

OBJECTIVES: To evaluate the potential of contrast-enhanced mammography (CEM) for reducing the biopsy rate of screening recalls. METHODS: Recalled women were prospectively enrolled to undergo CEM alongside standard assessment (SA) through additional views, tomosynthesis, and/or ultrasound. Exclusion criteria were symptoms, implants, allergy to contrast agents, renal failure, and pregnancy. SA and CEM were independently evaluated by one of six radiologists, who recommended biopsy or 2-year follow-up. Biopsy rates according to SA or recombined CEM (rCEM) were compared with the McNemar's test. Diagnostic performance was calculated considering lesions with available final histopathology. RESULTS: Between January 2019 and July 2021, 220 women were enrolled, 207 of them (median age 56.6 years) with 225 suspicious findings analysed. Three of 207 patients (1.4%) developed mild self-limiting adverse reactions to iodinated contrast agent. Overall, 135/225 findings were referred for biopsy, 90/225 by both SA and rCEM, 41/225 by SA alone and 4/225 by rCEM alone (2/4 being one DCIS and one invasive carcinoma). The rCEM biopsy rate (94/225, 41.8%, 95% CI 35.5-48.3%) was 16.4% lower (p < 0.001) than the SA biopsy rate (131/225, 58.2%, 95% CI 51.7-64.5%). Considering the 124/135 biopsies with final histopathology (44 benign, 80 malignant), rCEM showed a 93.8% sensitivity (95% CI 86.2-97.3%) and a 65.9% specificity (95% CI 51.1-78.1%), all 5 false negatives being ductal carcinoma in situ detectable as suspicious calcifications on low-energy images. CONCLUSIONS: Compared to SA, the rCEM-based work-up would have avoided biopsy for 37/225 (16.4%) suspicious findings. Including low-energy images in interpretation provided optimal overall CEM sensitivity. KEY POINTS: • The work-up of suspicious findings detected at mammographic breast cancer screening still leads to a high rate of unnecessary biopsies, involving between 2 and 6% of screened women. • In 207 recalled women with 225 suspicious findings, recombined images of contrast-enhanced mammography (CEM) showed a 93.8% sensitivity and a 65.9% specificity, all 5 false negatives being ductal carcinoma in situ detectable on low-energy images as suspicious calcifications. • CEM could represent an easily available one-stop shop option for the morphofunctional assessment of screening recalls, potentially reducing the biopsy rate by 16.4%.


Assuntos
Neoplasias da Mama , Calcinose , Carcinoma Intraductal não Infiltrante , Humanos , Feminino , Pessoa de Meia-Idade , Carcinoma Intraductal não Infiltrante/patologia , Mamografia/métodos , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Detecção Precoce de Câncer/métodos , Calcinose/patologia , Meios de Contraste/farmacologia
14.
Eur Radiol ; 32(3): 1624-1633, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34480624

RESUMO

OBJECTIVES: To report and analyse the characteristics and performance of the first cohort of Italian radiologists completing the national mammography self-evaluation online test established by the Italian Society of Medical Radiology (SIRM). METHODS: A specifically-built dataset of 132 mammograms (24 with screen-detected cancers and 108 negative cases) was preliminarily tested on 48 radiologists to define pass thresholds (62% sensitivity and 86% specificity) and subsequently made available online to SIRM members during a 13-month timeframe between 2018 and 2019. Associations between participants' characteristics, pass rates, and diagnostic accuracy were then investigated with descriptive statistics and univariate and multivariable regression analyses. RESULTS: A total of 342 radiologists completed the test, 151/342 (44.2%) with success. All individual variables, except gender, showed a significant correlation with pass rates and diagnostic sensitivity, confirmed by univariate logistic regression, while only involvement in organised screening programs and number of mammograms read per year showed a positive association with specificity at univariate logistic regression. In the multivariable regression analysis, fewer variables remained significant: > 3000 mammograms read per year for success rate; female gender, public practice setting, and higher experience self-judgement for sensitivity; no variables were significantly associated with specificity. CONCLUSIONS: This national self-evaluation test effectively differentiated multiple aspects of mammographic reading experience, but specific breast imaging experience was shown not to strictly guarantee good diagnostic accuracy. Due to its easy use and the validity of obtained results, this test could be extended to all Italian breast radiologists, regardless of their experience, also as a Breast Unit accreditation criterion. KEY POINTS: • This self-evaluation test was found to be able to differentiate various degrees of mammographic interpretation experience. • Breast cancer screening readers should undergo a self-assessment test, since experience parameters alone do not guarantee diagnostic ability.


Assuntos
Neoplasias da Mama , Radiologia , Neoplasias da Mama/diagnóstico por imagem , Autoavaliação Diagnóstica , Feminino , Humanos , Mamografia , Programas de Rastreamento , Autoavaliação (Psicologia) , Sensibilidade e Especificidade
15.
Eur Radiol ; 32(6): 4036-4045, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35258677

RESUMO

Breast density is an independent risk factor for the development of breast cancer and also decreases the sensitivity of mammography for screening. Consequently, women with extremely dense breasts face an increased risk of late diagnosis of breast cancer. These women are, therefore, underserved with current mammographic screening programs. The results of recent studies reporting on contrast-enhanced breast MRI as a screening method in women with extremely dense breasts provide compelling evidence that this approach can enable an important reduction in breast cancer mortality for these women and is cost-effective. Because there is now a valid option to improve breast cancer screening, the European Society of Breast Imaging (EUSOBI) recommends that women should be informed about their breast density. EUSOBI thus calls on all providers of mammography screening to share density information with the women being screened. In light of the available evidence, in women aged 50 to 70 years with extremely dense breasts, the EUSOBI now recommends offering screening breast MRI every 2 to 4 years. The EUSOBI acknowledges that it may currently not be possible to offer breast MRI immediately and everywhere and underscores that quality assurance procedures need to be established, but urges radiological societies and policymakers to act on this now. Since the wishes and values of individual women differ, in screening the principles of shared decision-making should be embraced. In particular, women should be counselled on the benefits and risks of mammography and MRI-based screening, so that they are capable of making an informed choice about their preferred screening method. KEY POINTS: • The recommendations in Figure 1 summarize the key points of the manuscript.


Assuntos
Densidade da Mama , Neoplasias da Mama , Mama/diagnóstico por imagem , Neoplasias da Mama/diagnóstico por imagem , Detecção Precoce de Câncer/métodos , Feminino , Humanos , Mamografia/métodos , Programas de Rastreamento/métodos
16.
Eur Radiol ; 32(3): 1611-1623, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34643778

RESUMO

OBJECTIVES: Preoperative breast magnetic resonance imaging (MRI) can inform surgical planning but might cause overtreatment by increasing the mastectomy rate. The Multicenter International Prospective Analysis (MIPA) study investigated this controversial issue. METHODS: This observational study enrolled women aged 18-80 years with biopsy-proven breast cancer, who underwent MRI in addition to conventional imaging (mammography and/or breast ultrasonography) or conventional imaging alone before surgery as routine practice at 27 centers. Exclusion criteria included planned neoadjuvant therapy, pregnancy, personal history of any cancer, and distant metastases. RESULTS: Of 5896 analyzed patients, 2763 (46.9%) had conventional imaging only (noMRI group), and 3133 (53.1%) underwent MRI that was performed for diagnosis, screening, or unknown purposes in 692/3133 women (22.1%), with preoperative intent in 2441/3133 women (77.9%, MRI group). Patients in the MRI group were younger, had denser breasts, more cancers ≥ 20 mm, and a higher rate of invasive lobular histology than patients who underwent conventional imaging alone (p < 0.001 for all comparisons). Mastectomy was planned based on conventional imaging in 22.4% (MRI group) versus 14.4% (noMRI group) (p < 0.001). The additional planned mastectomy rate in the MRI group was 11.3%. The overall performed first- plus second-line mastectomy rate was 36.3% (MRI group) versus 18.0% (noMRI group) (p < 0.001). In women receiving conserving surgery, MRI group had a significantly lower reoperation rate (8.5% versus 11.7%, p < 0.001). CONCLUSIONS: Clinicians requested breast MRI for women with a higher a priori probability of receiving mastectomy. MRI was associated with 11.3% more mastectomies, and with 3.2% fewer reoperations in the breast conservation subgroup. KEY POINTS: • In 19% of patients of the MIPA study, breast MRI was performed for screening or diagnostic purposes. • The current patient selection to preoperative breast MRI implies an 11% increase in mastectomies, counterbalanced by a 3% reduction of the reoperation rate. • Data from the MIPA study can support discussion in tumor boards when preoperative MRI is under consideration and should be shared with patients to achieve informed decision-making.


Assuntos
Neoplasias da Mama , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Mama , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/cirurgia , Feminino , Humanos , Imageamento por Ressonância Magnética , Mastectomia , Mastectomia Segmentar , Pessoa de Meia-Idade , Cuidados Pré-Operatórios , Adulto Jovem
17.
Neuroradiology ; 64(5): 905-913, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-34647143

RESUMO

PURPOSE: Imaging of brain involvement in infective endocarditis can drive the clinical management of this serious condition. MRI is very sensitive, but CT is more readily available. In this retrospective study, we compared the detection rates of CT and MRI. METHODS: After Ethics Committee approval, we retrospectively reviewed a series of 20 patients (13 males, median age 64 years) who underwent both CT and MRI either before or after cardiac surgery for definite infective endocarditis. Plain CT and MRI were evaluated for acute ischemic lesions, both punctuate and large, intraparenchymal hemorrhages, cerebral microbleeds, subarachnoid hemorrhages, abscesses, microabscesses, and meningitis. Qualitative assessment and McNemar test were performed. The value of contrast-enhanced scans (MRI, n = 14; CT, n = 9) and cognitive status were also assessed. RESULTS: A total of 166 lesions were identified on either technique: 137 (83%) on MRI only, 4 (2%) on CT only, and 25 (15%) on both techniques (p < 0.001). For these last 25 lesions, concordance on lesion type was only 16/25 (64%). MRI detected more microbleeds and ischemic lesions, while the 4 CT-only findings were false positives. Contrast-enhanced scans identified 68 enhancing lesions, mainly abscesses and microabscesses, and allowed a better characterization for 61/117 lesions (52%) with MRI, and for 11/81 (14%) with CT. Follow-up identified mild cognitive impairment in 6/13 and dementia in 3/13 patients. CONCLUSION: While CT rapidly excludes large hemorrhages in patients with infective endocarditis, MRI accurately distinguishes the whole spectrum of brain lesions, including small ischemic lesions, microbleeds, and microabscesses.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Endocardite , Abscesso/patologia , Encéfalo/diagnóstico por imagem , Encéfalo/patologia , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Hemorragia Cerebral/diagnóstico por imagem , Hemorragia Cerebral/patologia , Endocardite/diagnóstico por imagem , Endocardite/patologia , Endocardite/cirurgia , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
18.
Radiol Med ; 127(10): 1151-1158, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36057931

RESUMO

PURPOSE: Bone Strain Index (BSI) is a recently developed dual-energy X-ray absorptiometry (DXA) software, applying a finite element analysis on lumbar spine and femoral DXA scans. BSI is a parameter of bone deformation, providing information on bone resistance to applied loads. BSI values indicate the average bone strain in the explored site, where a higher strain (higher BSI values) suggests a higher fracture risk. This study reports the distributional characteristics of lumbar BSI (L-BSI) in women with normal bone mass, osteopenia or osteoporosis and their relationships with BMD, weight, height and BMI. MATERIAL AND METHODS: Two-hundred-fifty-nine consecutive unfractured women who performed DXA were divided into three groups based on BMD T-score: normal bone mass (n = 43, 16.6%), osteopenia (n = 82, 31.7%) and osteoporosis (n = 134, 51.7%). The distribution of L-BSI was evaluated with conventional statistical methods, histograms and by calculating parametric and nonparametric 95% confidence intervals, together with the 90%, 95% and 99% bilateral tolerance limits with a 95% confidence. RESULTS: Ninety percent bilateral tolerance limits with 95% confidence for L-BSI distribution are 1.0-2.40, 0.95-2.63 and 0.84-3.15 in the group of patients with normal bone mass, 1.34-2.78, 1.24-2.95 and 1.05-3.32 in the osteopenic group and 1.68-3.79, 1.58-4.15 and 1.40-4.96 in the osteoporotic group. CONCLUSION: In women without vertebral fractures at baseline, L-BSI values from 1.68 (osteoporotic group) and 2.40 (upper of the normal bone mass group) can be tentatively chosen as a lower and upper threshold to stratify postmenopausal women according to their bone resistance to loads.


Assuntos
Doenças Ósseas Metabólicas , Osteoporose , Absorciometria de Fóton/métodos , Densidade Óssea , Doenças Ósseas Metabólicas/diagnóstico por imagem , Doenças Ósseas Metabólicas/epidemiologia , Feminino , Humanos , Vértebras Lombares/diagnóstico por imagem , Osteoporose/diagnóstico por imagem
19.
Radiol Med ; 127(5): 484-489, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35347582

RESUMO

INTRODUCTION: In 2016, the Italian Group for Mammography Screening and the Italian College of Breast Radiologists by the Italian Society of Medical and Interventional Radiology recommended that screening programmes and specialist breast centres actively invite women with a history of breast cancer to follow-up imaging. OBJECTIVE: A survey of breast centres associated with Senonetwork, the Italian network of breast cancer services, has offered the opportunity to assess the implementation of this recommendation. METHODS: A national, cross-sectional, voluntary, online survey was developed, pre-tested, and administered during the months July-October 2020. Five of the 73 questionnaire items concerned breast cancer follow-up. RESULTS: The response rate was 82/128 (65%). Of the 82 respondent centres, 69 (84%) were involved in a screening programme. Fifty-six (68%) reported the presence of a programme of active invitation to breast cancer follow-up targeted at patients living in their catchment area, with a significant north-to-south gradient. Four centres (5%) reported that the screening programme was responsible for actively initiating follow-up during the 10-year period since diagnosis. Only after 10 years did the proportion increase moderately. CONCLUSION: Screening programmes have still a marginal role in active breast cancer follow-up.


Assuntos
Neoplasias da Mama , Detecção Precoce de Câncer , Assistência ao Convalescente , Neoplasias da Mama/diagnóstico por imagem , Estudos Transversais , Feminino , Humanos , Mamografia , Programas de Rastreamento , Radiologistas
20.
Radiol Med ; 127(5): 471-483, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35303247

RESUMO

BACKGROUND: Radiology is an essential tool in the management of a patient. The aim of this manuscript was to build structured report (SR) Mammography based in Breast Cancer. METHODS: A working team of 16 experts (group A) was composed to create a SR for Mammography Breast Cancer. A further working group of 4 experts (group B), blinded to the activities of the group A, was composed to assess the quality and clinical usefulness of the SR final draft. Modified Delphi process was used to assess level of agreement for all report sections. Cronbach's alpha (Cα) correlation coefficient was used to assess internal consistency and to measure quality analysis according to the average inter-item correlation. RESULTS: The final SR version was built by including n = 2 items in Personal Data, n = 4 items in Setting, n = 2 items in Comparison with previous breast examination, n = 19 items in Anamnesis and clinical context; n = 10 items in Technique; n = 1 item in Radiation dose; n = 5 items Parenchymal pattern; n = 28 items in Description of the finding; n = 12 items in Diagnostic categories and Report and n = 1 item in Conclusions. The overall mean score of the experts and the sum of score for structured report were 4.9 and 807 in the second round. The Cronbach's alpha (Cα) correlation coefficient was 0.82 in the second round. About the quality evaluation, the overall mean score of the experts was 3.3. The Cronbach's alpha (Cα) correlation coefficient was 0.90. CONCLUSIONS: Structured reporting improves the quality, clarity and reproducibility of reports across departments, cities, countries and internationally and will assist patient management and improve breast health care and facilitate research.


Assuntos
Neoplasias da Mama , Neoplasias da Mama/diagnóstico por imagem , Técnica Delphi , Feminino , Humanos , Mamografia , Reprodutibilidade dos Testes , Raios X
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa