Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 249
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Cardiovasc Electrophysiol ; 35(1): 44-57, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37927196

RESUMO

BACKGROUND: Intracardiac echocardiography (ICE) is increasingly used during left atrial appendage occlusion (LAAO) as an alternative to transesophageal echocardiography (TEE). The objective of this study is to evaluate the impact of ICE versus TEE guidance during LAAO on procedural characteristics and acute outcomes, as well the presence of peri-device leaks and residual septal defects during follow-up. METHODS: All studies comparing ICE-guided versus TEE-guided LAAO were identified. The primary outcomes were procedural efficacy and occurrence of procedure-related complications. Secondary outcomes included lab efficiency (defined as a reduction in in-room time), procedural time, fluoroscopy time, and presence of peri-device leaks and residual interatrial septal defects (IASD) during follow-up. RESULTS: Twelve studies (n = 5637) were included. There were no differences in procedural success (98.3% vs. 97.8%; OR 0.73, 95% CI 0.42-1.27, p = .27; I2 = 0%) or adverse events (4.5% vs. 4.4%; OR 0.81 95% CI 0.56-1.16, p = .25; I2 = 0%) between the ICE-guided and TEE-guided groups. ICE guidance reduced in in-room time (mean-weighted 28.6-min reduction in in-room time) without differences in procedural time or fluoroscopy time. There were no differences in peri-device leak (OR 0.93, 95% CI 0.68-1.27, p = 0.64); however, an increased prevalence of residual IASD was observed with ICE-guided versus TEE-guided LAAO (46.3% vs. 34.2%; OR 2.23, 95% CI 1.05-4.75, p = 0.04). CONCLUSION: ICE guidance is associated with similar procedural efficacy and safety, but could result in improved lab efficiency (as established by a significant reduction in in-room time). No differences in the rate of periprocedural leaks were found. A higher prevalence of residual interatrial septal defects was observed with ICE guidance.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Humanos , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Fibrilação Atrial/complicações , Ecocardiografia Transesofagiana , Resultado do Tratamento
2.
Artigo em Inglês | MEDLINE | ID: mdl-38994680

RESUMO

INTRODUCTION: Scar substrate in nonischemic cardiomyopathy (NICM) patients is often difficult to identify. Advances in cardiac imaging, especially using late iodine-enhanced computed tomography (LIE-CT), allow better characterization of scars giving rise to ventricular tachycardia (VT). Currently, there are limited data on clinical correlates of CT-derived scar substrates in NICM. We sought assess the relationship between scar location on LIE-CT and outcomes after radiofrequency catheter ablation (RFCA) in NICM patients with VT. METHODS: From 2020 to 2022, consecutive patients with NICM undergoing VT RFCA with integration of cardiac CT scar modeling (inHeart, Pessac, France) were included at two US tertiary care centers. The CT protocol included both arterial-enhanced imaging for anatomical modeling and LIE-CT for scar assessment. The distribution of substrate on CT was analyzed in relation to patient outcomes, with primary endpoints being VT recurrence and the need for repeat ablation procedure. RESULTS: Sixty patients were included (age 64 ± 12 years, 90% men). Over a median follow-up of 120 days (interquartile range [IQR]: 41-365), repeat ablation procedures were required in 32 (53%). VT recurrence occurred in 46 (77%), with a median time to recurrence of 40 days (IQR: 8-65). CT-derived total scar volume positively correlated with intrinsic QRS duration (r = .34, p = 0.008). Septal scar was found on CT in 34 (57%), and lateral scar in 40 (7%). On univariate logistic regression, septal scar was associated with increased odds of repeat ablation (odds ratio [OR]: 2.9 [1.0-8.4]; p = 0.046), while lateral scar was not (OR: 0.9 [0.3-2.7]; p = 0.855). Septal scar better predicted VT recurrence when compared to lateral scar, but neither were statistically significant (septal scar OR: 3.0 [0.9-10.7]; p = 0.078; lateral scar OR: 1.7 [0.5-5.9]; p = 0.391). CONCLUSION: In this tertiary care referral population, patients with NICM undergoing VT catheter ablation with septal LIE-CT have nearly threefold increased risk of need for repeat ablation.

3.
Artigo em Inglês | MEDLINE | ID: mdl-38924224

RESUMO

INTRODUCTION: Training in clinical cardiac electrophysiology (CCEP) involves the development of catheter handling skills to safely deliver effective treatment. Objective data from analysis of ablation data for evaluating trainee of CCEP procedures has not previously been possible. Using the artificial intelligence cloud-based system (CARTONET), we assessed the impact of trainee progress through ablation procedural quality. METHODS: Lesion- and procedure-level data from all de novo atrial fibrillation (AF) and cavotricuspid isthmus (CTI) ablations involving first-year (Y1) or second-year (Y2) fellows across a full year of fellowship was curated within Cartonet. Lesions were automatically assigned to anatomic locations. RESULTS: Lesion characteristics, including contact force, catheter stability, impedance drop, ablation index value, and interlesion time/distance were similar over each training year. Anatomic location and supervising operator significantly affected catheter stability. The proportion of lesion sets delivered independently and of lesions delivered by the trainee increased steadily from the first quartile of Y1 to the last quartile of Y2. Trainee perception of difficult regions did not correspond to objective measures. CONCLUSION: Objective ablation data from Cartonet showed that the progression of trainees through CCEP training does not impact lesion-level measures of treatment efficacy (i.e., catheter stability, impedance drop). Data demonstrates increasing independence over a training fellowship. Analyses like these could be useful to inform individualized training programs and to track trainee's progress. It may also be a useful quality assurance tool for ensuring ongoing consistency of treatment delivered within training institutions.

4.
Br J Anaesth ; 132(4): 779-788, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38087741

RESUMO

BACKGROUND: We investigated the effects of ketamine on desaturation and the risk of nursing home discharge in patients undergoing procedural sedation by anaesthetists. METHODS: We included adult patients who underwent procedures under monitored anaesthetic care between 2005 and 2021 at two academic healthcare networks in the USA. The primary outcome was intraprocedural oxygen desaturation, defined as oxygen saturation <90% for ≥2 consecutive minutes. The co-primary outcome was a nursing home discharge. RESULTS: Among 234,170 included patients undergoing procedural sedation, intraprocedural desaturation occurred in 5.6% of patients who received ketamine vs 5.2% of patients who did not receive ketamine (adjusted odds ratio [ORadj] 1.22, 95% confidence interval [CI] 1.15-1.29, P<0.001; adjusted absolute risk difference [ARDadj] 1%, 95% CI 0.7-1.3%, P<0.001). The effect was magnified by age >65 yr, smoking, or preprocedural ICU admission (P-for-interaction <0.001, ORadj 1.35, 95% CI 1.25-1.45, P<0.001; ARDadj 2%, 95% CI 1.56-2.49%, P<0.001), procedural risk factors (upper endoscopy of longer than 2 h; P-for-interaction <0.001, ORadj 2.91, 95% CI 1.85-4.58, P<0.001; ARDadj 16.2%, 95% CI 9.8-22.5%, P<0.001), and high ketamine dose (P-for-trend <0.001, ORadj 1.61, 95% CI, 1.43-1.81 for ketamine >0.5 mg kg-1). Concomitant opioid administration mitigated the risk (P-for-interaction <0.001). Ketamine was associated with higher odds of nursing home discharge (ORadj 1.11, 95% CI 1.02-1.21, P=0.012; ARDadj 0.25%, 95% CI 0.05-0.46%, P=0.014). CONCLUSIONS: Ketamine use for procedural sedation was associated with an increased risk of oxygen desaturation and discharge to a nursing home. The effect was dose-dependent and magnified in subgroups of vulnerable patients.


Assuntos
Ketamina , Adulto , Humanos , Ketamina/efeitos adversos , Estudos Retrospectivos , Hospitais , Sistema de Registros , Serviço Hospitalar de Emergência , Oxigênio , Atenção à Saúde , Aceitação pelo Paciente de Cuidados de Saúde , Sedação Consciente/métodos , Hipnóticos e Sedativos
5.
Am Heart J ; 261: 95-103, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37019195

RESUMO

BACKGROUND: Atrial fibrillation (AF) is the most common arrhythmia encountered in clinical practice and is associated with significant morbidity, mortality, and financial burden. Obstructive sleep apnea (OSA) is more common in individuals with AF and may impair the efficacy of rhythm control strategies including catheter ablation. However, the prevalence of undiagnosed OSA in all-comers with AF is unknown. DESIGN: This pragmatic, phase IV prospective cohort study will test 250-300 consecutive ambulatory AF patients with all patterns of atrial fibrillation (paroxysmal, persistent, and long-term persistent) and no prior sleep testing for OSA using the WatchPAT system, a disposable home sleep test (HST). The primary outcome of the study is the prevalence of undiagnosed OSA in all-comers with atrial fibrillation. RESULTS: Preliminary results from the initial pilot enrollment of approximately 15% (N = 38) of the planned sample size demonstrate a 79.0% prevalence of at least mild (AHI≥5) OSA or greater in consecutively enrolled patient with all patterns of AF. CONCLUSIONS: We report the design, methodology, and preliminary results of our study to define the prevalence of OSA in AF patients. This study will help inform approaches to OSA screening in patients with AF for which there is currently little practical guidance. CLINICAL TRIAL REGISTRATION: NCT05155813.


Assuntos
Fibrilação Atrial , Apneia Obstrutiva do Sono , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/complicações , Estudos Prospectivos , Fatores de Risco , Sono , Apneia Obstrutiva do Sono/diagnóstico , Apneia Obstrutiva do Sono/epidemiologia , Apneia Obstrutiva do Sono/complicações
6.
J Cardiovasc Electrophysiol ; 34(4): 918-927, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36852908

RESUMO

INTRODUCTION: The association between ambient circulating environments (CEs) and ablation lesions has been largely underexplored. METHODS: Viable bovine myocardium was placed in a saline bath in an ex vivo endocardial model. Radiofrequency (RF) ablation was performed using three different ablation catheters: 3.5 mm open irrigated (OI), 4, and 8 mm. Variable flow rates of surrounding bath fluids were applied to simulate standard flow, high flow, and no flow. For in vivo epicardial ablation, 24 rats underwent a single OI ablation and performed with circulating saline (30 ml/min; n = 12), versus those immersed in saline without circulation (n = 12). RESULTS: High flow reduced ablation lesion volumes for all three catheters. In no-flow endocardial CE, both 4 mm and OI catheters produced smaller lesions compared with standard flow. However, the 8 mm catheter produced the largest lesions in a no-flow CE. Ablation performed in an in vivo model with CE resulted in smaller lesions compared with ablation performed in a no-flow environment. No statistically significant differences in steam pops were found among the groups. CONCLUSION: A higher endocardial CE flow can decrease RF effectiveness. Cardiac tissue subjected to no endocardial CE flow may also limit RF for 4 mm catheters, but not for OI catheters; these findings may have implications for RF ablation safety and efficacy, especially in the epicardial space without circulating fluid or in the endocardium under varying flow conditions.


Assuntos
Coração , Miocárdio , Animais , Bovinos , Ratos , Desenho de Equipamento , Miocárdio/patologia , Endocárdio/cirurgia , Catéteres
7.
J Cardiovasc Electrophysiol ; 34(4): 880-887, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36682068

RESUMO

INTRODUCTION: Esophageal injury is a well-known complication associated with catheter ablation. Though novel methods to mitigate esophageal injury have been developed, few studies have evaluated temperature gradients with catheter ablation across the posterior wall of the left atrium, interstitium, and esophagus. METHODS: To investigate temperature gradients across the tissue, we developed a porcine heart-esophageal model to perform ex vivo catheter ablation on the posterior wall of the left atrium (LA), with juxtaposed interstitial tissue and esophagus. Circulating saline (5 L/min) was used to mimic blood flow along the LA and alteration of ionic content to modulate impedance. Thermistors along the region of interest were used to analyze temperature gradients. Varying time and power, radiofrequency (RF) ablation lesions were applied with an externally irrigated ablation catheter. Ablation strategies were divided into standard approaches (SAs, 10-15 g, 25-35 W, 30 s) or high-power short duration (HPSD, 10-15 g, 40-50 W, 10 s). Temperature gradients, time to the maximum measured temperature, and the relationship between measured temperature as a function of distance from the site of ablation was analyzed. RESULTS: In total, five experiments were conducted each utilizing new porcine posterior LA wall-esophageal specimens for RF ablation (n = 60 lesions each for SA and HPSD). For both SA and HPSD, maximum temperature rise from baseline was markedly higher at the anterior wall (AW) of the esophagus compared to the esophageal lumen (SA: 4.29°C vs. 0.41°C, p < .0001 and HPSD: 3.13°C vs. 0.28°C, p < .0001). Across ablation strategies, the average temperature rise at the AW of the esophagus was significantly higher with SA relative to HPSD ablation (4.29°C vs. 3.13°C, p = .01). From the start of ablation, the average time to reach a maximum temperature as measured at the AW of the esophagus with SA was 36.49 ± 12.12 s, compared to 16.57 ± 4.54 s with HPSD ablation, p < .0001. Fit to a linear scale, a 0.37°C drop in temperature was seen for every 1 cm increase in distance from the site of ablation and thermistor location at the AW of the esophagus. CONCLUSION: Both SA and HPSD ablation strategies resulted in markedly higher temperatures measured at the AW of the esophagus compared to the esophageal lumen, raising concern about the value of clinical intraluminal temperature monitoring. The temperature rise at the AW was lower with HPSD. A significant time delay was seen to reach the maximum measured temperature and a modest increase in distance between the site of ablation and thermistor location impacted the accuracy of monitored temperatures.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Animais , Suínos , Temperatura , Fibrilação Atrial/cirurgia , Átrios do Coração , Esôfago/lesões , Ablação por Cateter/métodos
8.
J Cardiovasc Electrophysiol ; 33(4): 690-695, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35133050

RESUMO

INTRODUCTION: Ablation of papillary muscles (PMs) for refractory ventricular arrhythmias can often be challenging. The catheter approach and orientation during ablation may affect optimal radiofrequency (RF) delivery. Yet, no previous study investigated the association between catheter orientation and PM lesion size. We evaluated ablation lesion characteristics with various catheter orientations relative to the PM tissue during open irrigated ablation, using a standardized, experimental setting. METHODS: Viable bovine PM was positioned on a load cell in a circulating saline bath. RF ablation was performed over PM tissue at 50 W, with the open irrigated catheter positioned either perpendicular or parallel to the PM surface. Applied force was 10 g. Ablation lesions were sectioned and underwent quantitative morphometric analysis. RESULTS: A catheter position oriented directly perpendicular to the PM tissue resulted in the largest ablation lesion volumes and depths compared with ablation with the catheter parallel to PM tissue (75.26 ± 8.40 mm3 vs. 34.04 ± 2.91 mm3 , p < .001) and (3.33 ± 0.18 mm vs. 2.24 ± 0.10 mm, p < .001), respectively. There were no significant differences in initial impedance, peak voltage, peak current, or overall decrease in impedance among groups. Parallel catheter orientation resulted in higher peak temperature (41.33 ± 0.28°C vs. 40.28 ± 0.24°C, p = .003), yet, there were no steam pops in either group. CONCLUSION: For PM ablation, catheter orientation perpendicular to the PM tissue achieves more effective and larger ablation lesions, with greater lesion depth. This may have implications for the chosen ventricular access approach, the type of catheter used, consideration for remote navigation, and steerable sheaths.


Assuntos
Ablação por Cateter , Músculos Papilares , Animais , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Catéteres , Bovinos , Ventrículos do Coração/cirurgia , Músculos Papilares/diagnóstico por imagem , Músculos Papilares/cirurgia , Irrigação Terapêutica/efeitos adversos , Irrigação Terapêutica/métodos
9.
Rheumatol Int ; 42(10): 1767-1774, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35430712

RESUMO

COVID-19 raised concern regarding cardiotoxicity and QTc prolongation of hydroxychloroquine (HCQ) and chloroquine (CQ). We examined the frequency and patient factors associated with ECG testing and the detection of prolonged QTc among new HCQ/CQ users in a large academic medical system. 10,248 subjects with a first HCQ/CQ prescription (1/2015-3/2020) were included. We assessed baseline (1 year prior to and including day of initiation of HCQ/CQ through 2 months after initial HCQ/CQ prescription) and follow-up (10 months after the baseline period) patient characteristics and ECGs obtained from electronic health records. Among 8384 female HCQ/CQ new users, ECGs were obtained for 22.3%, 14.3%, and 7.6%, at baseline, follow, and both periods, respectively. Among 1864 male HCQ/CQ new users, ECGs were obtained more frequently at baseline (29.7%), follow-up (18.0%), and both periods (11.3%). Female HCQ/CQ users with a normal QTc at baseline but prolonged QTc (> 470 ms) at follow-up (13.1%) were older at HCQ/CQ initiation [mean 64.7 (SD 16.5) vs. 58.7 (SD 16.9) years, p = 0.004] and more likely to have history of myocardial infarction (41.0% vs. 21.6%, p = 0.0003) compared to those who had normal baseline and follow-up QTc. The frequency of prolonged QTc development was similar (12.4%) among male HCQ/CQ new users (> 450 ms). Prior to COVID-19, ECG testing before and after HCQ/CQ prescription was infrequent, particularly for females who are disproportionately affected by rheumatic diseases and were just as likely to develop prolonged QTc (> 1/10 new users). Prospective studies are needed to guide future management of HCQ/CQ therapy in rheumatic populations.


Assuntos
Tratamento Farmacológico da COVID-19 , COVID-19 , Hidroxicloroquina , COVID-19/epidemiologia , Cloroquina/efeitos adversos , Eletrocardiografia , Feminino , Humanos , Hidroxicloroquina/efeitos adversos , Masculino , Prevalência , SARS-CoV-2 , Centros de Atenção Terciária
11.
J Cardiovasc Electrophysiol ; 32(2): 409-416, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33355965

RESUMO

INTRODUCTION: Patients with prior cardiac surgery may represent a subgroup of patients with ventricular tachycardia (VT) that may be more difficult to control with catheter ablation. METHODS: We evaluated 1901 patients with ischemic and nonischemic cardiomyopathy who underwent VT ablation at 12 centers. Clinical characteristics and VT radiofrequency ablation procedural outcomes were assessed and compared between those with and without prior cardiac surgery. Kaplan-Meier analysis was used to estimate freedom from recurrent VT and survival. RESULTS: There were 578 subjects (30.4%) with prior cardiac surgery identified in the cohort. Those with prior cardiac surgery were older (66.4 ± 11.0 years vs. 60.5 ± 13.9 years, p < .01), with lower left ventricular ejection fraction (30.2 ± 11.5% vs. 34.8 ± 13.6%, p < .01) and more ischemic heart disease (82.5% vs. 39.3%, p < .01) but less likely to undergo epicardial mapping or ablation (9.0% vs. 38.1%, p<.01) compared to those without prior surgery. When epicardial mapping was performed, a significantly greater proportion required surgical intervention for access (19/52 [36.5%] vs. 14/504 [2.8%]; p < .01). Procedural complications, including epicardial access-related complications, were lower (5.7% vs. 7.0%, p < .01) in patients with versus without prior cardiac surgery. VT-free survival (75.1% vs. 74.1%, p = .805) and survival (86.5% vs. 87.9%, p = .397) were not different between those with and without prior heart surgery, regardless of etiology of cardiomyopathy. VT recurrence was associated with increased mortality in patients with and without prior cardiac surgery. CONCLUSION: Despite different clinical characteristics and fewer epicardial procedures, the safety and efficacy of VT ablation in patients with prior cardiac surgery is similar to others in this cohort. The incremental yield of epicardial mapping in predominant ischemic cardiomyopathy population prior heart surgery may be low but appears safe in experienced centers.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Ablação por Cateter , Taquicardia Ventricular , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Ablação por Cateter/efeitos adversos , Humanos , Pericárdio/cirurgia , Recidiva , Volume Sistólico , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Resultado do Tratamento , Função Ventricular Esquerda
12.
Pacing Clin Electrophysiol ; 44(1): 185-188, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32794265

RESUMO

A 40-year-old man presented to our emergency department 2 hours after onset of shortness of breath, palpitations, and presyncope secondary to an adenosine-responsive wide complex tachycardia. Electrophysiology study was diagnostic for antidromic atrioventricular (AV) reentrant tachycardia utilizing a muscular connection from the anterior interventricular vein to the left ventricle with Mahaim-like properties, successfully treated with ablation in the distal coronary sinus (CS) system. This case highlights accessory pathways (a) with unique features (i.e., Mahaim-like characteristics) and (b) involving musculature from the distal CS system, thereby limiting the value of endocardial ablation for durable treatment. Importantly, the coronary venous system is an accessible vascular network for evaluation and catheter ablation of such arrhythmias.


Assuntos
Ablação por Cateter/métodos , Seio Coronário/cirurgia , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Feixe Acessório Atrioventricular/fisiopatologia , Adulto , Diagnóstico Diferencial , Eletrocardiografia , Humanos , Masculino , Taquicardia por Reentrada no Nó Atrioventricular/fisiopatologia
15.
J Cardiovasc Electrophysiol ; 31(7): 1687-1693, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32323395

RESUMO

BACKGROUND: Interrupted ablation is increasingly proposed as part of high-power short-duration radiofrequency ablation (RFA) strategies and may also result from loss of contact from respiratory patterns or cardiac motion. To study the extent that ablation interruption affects lesions. METHODS: In ex vivo and in vivo experiments, lesion characteristics and tissue temperatures were compared between continuous (group 1) and interrupted (groups 2 and 3) RFA with equal total ablation duration and contact force. Extended duration ablation lesions were also characterized from 1 to 5 minutes. RESULTS: In the ex vivo study, continuous RFA (group 1) produced larger total lesion volumes compared with each interrupted ablation lesion group (273.8 ± 36.5 vs 205.1 ± 34.2 vs 174.3 ± 32.3 mm3 , all P < .001). Peak temperatures for group 1 were higher at 3 and 5 mm than groups 2 and 3. In vivo, continuous ablation resulted in larger lesions, greater lesion depths, and higher tissue temperatures. Longer ablation durations created larger lesion volumes and increased lesion depths. However, after 3 minutes of ablation, the rate of lesion volume, and depth formation decreased. CONCLUSIONS: Continuous RFA delivery resulted in larger and deeper lesions with higher tissue temperatures compared with interrupted ablation. This study may have implications for high-power short duration ablation strategies, motivates strategies to reduce variations in ablation delivery, and provides an upper limit for ablation duration beyond which power delivery has diminishing returns.


Assuntos
Ablação por Cateter , Ablação por Radiofrequência , Ablação por Cateter/efeitos adversos , Temperatura Alta , Humanos , Ablação por Radiofrequência/efeitos adversos , Temperatura , Fatores de Tempo
16.
J Cardiovasc Electrophysiol ; 31(5): 1114-1124, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32031304

RESUMO

BACKGROUND: Epicardial adipose (EA) tissue may limit effective radiofrequency ablation (RFA). OBJECTIVES: We sought to evaluate the lesion formation of different ablation strategies on ventricular myocardium with overlying EA. METHODS: Bovine myocardium with EA was placed in a circulating saline bath in an ex vivo model. Open-irrigated (OI) RFA was performed, parallel to the myocardium, over fat at 50 W for variable RF durations, variable contact force, catheter configurations (unipolar RF vs bipolar RF), and catheter irrigants (normal saline vs half-normal saline). Ablation was also performed with a needle-tipped ablation catheter (NTAC), perpendicular to the myocardium. RESULTS: Increasingly thick EA attenuated lesion size regardless of ablation strategy. RF applied with longer durations and increasing CF produced larger lesion volumes and deeper lesions with ablation over EA more than 3 mm but was unable to produce measurable lesions when EA less than 3 mm. Similarly, ablation with half normal saline irrigant created slightly deeper lesions than bipolar RF and unipolar RF with normal saline as EA thickness increased, but was unable to produce measurable lesions when EA more than 3 mm. Of all ablation strategies, only NTAC produced effective lesion volumes when ablating over thick (>3 mm) EA. CONCLUSIONS: While EA attenuates lesion depth and size, relatively larger, and deeper lesions can be achieved with longer RFA duration, higher CF, half normal saline irrigant, and, to a greater extent, by utilizing bipolar RF or NTAC, but only over thin adipose (<3 mm). Of those catheters/strategies tested, only NTAC was able to effectively deliver RF over thick (>3 mm) EA with this model.


Assuntos
Tecido Adiposo/patologia , Adiposidade , Ablação por Cateter , Ventrículos do Coração/cirurgia , Miocárdio/patologia , Pericárdio/cirurgia , Irrigação Terapêutica , Animais , Cateteres Cardíacos , Ablação por Cateter/efeitos adversos , Ablação por Cateter/instrumentação , Bovinos , Desenho de Equipamento , Ventrículos do Coração/patologia , Técnicas In Vitro , Duração da Cirurgia , Pericárdio/patologia , Irrigação Terapêutica/efeitos adversos , Irrigação Terapêutica/instrumentação , Fatores de Tempo
17.
Europace ; 22(6): 897-905, 2020 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-32243508

RESUMO

AIMS: Persistent atrial fibrillation (AF) has been explained by multiple mechanisms which, while they conflict, all agree that more disorganized AF is more difficult to treat than organized AF. We hypothesized that persistent AF consists of interacting organized areas which may enlarge, shrink or coalesce, and that patients whose AF areas enlarge by ablation are more likely to respond to therapy. METHODS AND RESULTS: We mapped vectorial propagation in persistent AF using wavefront fields (WFF), constructed from raw unipolar electrograms at 64-pole basket catheters, during ablation until termination (Group 1, N = 20 patients) or cardioversion (Group 2, N = 20 patients). Wavefront field mapping of patients (age 61.1 ± 13.2 years, left atrium 47.1 ± 6.9 mm) at baseline showed 4.6 ± 1.0 organized areas, each separated by disorganization. Ablation of sites that led to termination controlled larger organized area than competing sites (44.1 ± 11.1% vs. 22.4 ± 7.0%, P < 0.001). In Group 1, ablation progressively enlarged unablated areas (rising from 32.2 ± 15.7% to 44.1 ± 11.1% of mapped atrium, P < 0.0001). In Group 2, organized areas did not enlarge but contracted during ablation (23.6 ± 6.3% to 15.2 ± 5.6%, P < 0.0001). CONCLUSION: Mapping wavefront vectors in persistent AF revealed competing organized areas. Ablation that progressively enlarged remaining areas was acutely successful, and sites where ablation terminated AF were surrounded by large organized areas. Patients in whom large organized areas did not emerge during ablation did not exhibit AF termination. Further studies should define how fibrillatory activity is organized within such areas and whether this approach can guide ablation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Cardioversão Elétrica , Átrios do Coração/cirurgia , Humanos , Pessoa de Meia-Idade
18.
J Extra Corpor Technol ; 52(3): 227-236, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32981961

RESUMO

As the extracorporeal membrane oxygenation (ECMO) program at our institution has grown and our staffing model has evolved into a multidisciplinary team, our method of ECMO charting has also evolved, using an electronic medical record (EMR) with electronic checklists, progress notes, and remote access. Using our EPIC charting platform, version 1 of our EMR was implemented in 2015. It has been revised three times, and remote access deemed necessary to properly support our staff and patients. Our current, yet still evolving, remotely accessible, ECMO EMR incorporates hourly charting and protocol-based checklists for procedures such as initiation of support, shift handoffs, circuit checks, and patient transport. Perfusionists are required to fill out thrice daily progress notes, notes for bedside/operating room procedures, and patient transport. We present a format for centers looking to implement a comprehensive EMR for ECMO patients. An expanding ECMO program required a change to our staffing model, and an EMR with electronic checklists and remote access facilitated the transition to a multidisciplinary team. Protocol-based checklists ensure consistency during procedures, transports, and shift changes. The remote access and required progress notes create a safer team approach and keep our perfusionists engaged when specialists are sitting ECMO.


Assuntos
Oxigenação por Membrana Extracorpórea , Lista de Checagem , Registros Eletrônicos de Saúde , Humanos , Equipe de Assistência ao Paciente
19.
J Cardiovasc Electrophysiol ; 30(12): 2960-2967, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31588608

RESUMO

INTRODUCTION: Both bipolar and simultaneous radiofrequency ablation (bRFA, simRFA) have been used to treat thick midmyocardial substrate as well as during circular, multipolar ablation between shorter distances. OBJECTIVES: We sought to evaluate the biophysical parameters of simRFA, sequential unipolar RFA (seqRFA), and bRFA. METHODS: Bovine myocardium was placed in a circulating saline bath. To simulate thick substrate conditions, two open irrigated ablation catheters were oriented across from each other, with myocardium in between. Thermocouples were placed in the center, ±2 mm, of the myocardium. Unipolar ablations were performed sequentially or simultaneously at 50 W for 60 seconds and compared to bRFA using the same settings. In addition, to simulate multipolar ablation, two open irrigated ablation catheters were oriented on the same side and perpendicular to myocardium at 1, 2, and 4 mm spacing. SimRFA were performed at 15 and 25 W for 60 seconds and compared to bRFA. RESULTS: For thicker tissue, simRFA produced similar lesion volume and depth compared to bRFA but with a lesion geometry similar to seqRFA. Unlike seqRFA and simRFA, bRFA had a necrotic core spanning the myocardium. Core depths, volumes, and temperatures were significantly greater for bRFA lesions compared to simRFA or seqRFA (Figure, P < .001). Similar results were consistent for bRFA and simRFA at shorter spacings. CONCLUSIONS: BRFA has greater core lesion temperatures, corresponding to a denser and larger necrotic core, than either simRFA or seqRFA. This may have implications for considering the optimal strategy for deep midmyocardial substrates or during multipolar ablation.


Assuntos
Cateteres Cardíacos , Miocárdio/patologia , Ablação por Radiofrequência/instrumentação , Irrigação Terapêutica/instrumentação , Animais , Bovinos , Técnicas In Vitro , Necrose , Ablação por Radiofrequência/efeitos adversos , Temperatura , Irrigação Terapêutica/efeitos adversos
20.
J Cardiovasc Electrophysiol ; 30(9): 1560-1568, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31111602

RESUMO

BACKGROUND: Ventricular tachycardia (VT) is frequently encountered in patients with repaired and unrepaired congenital heart disease (CHD), causing significant morbidity and sudden cardiac death. Data regarding underlying VT mechanisms and optimal ablation strategies in these patients remain limited. OBJECTIVE: To describe the electrophysiologic mechanisms, ablation strategies, and long-term outcomes in patients with CHD undergoing VT ablation. METHODS: Forty-eight patients (mean age 41.3 ± 13.3 years, 77.1% male) with CHD underwent a total of 57 VT ablation procedures at two centers from 2000 to 2017. Electrophysiologic and follow-up data were analyzed. RESULTS: Of the 77 different VTs induced at initial or repeat ablation, the underlying mechanism in 62 (81.0%) was due to scar-related re-entry; the remaining included four His-Purkinje system-related macrore-entry VTs and focal VTs mainly originating from the outflow tract region (8 of 11, 72.7%). VT-free survival after a single procedure was 72.9% (35 of 48) at a median follow-up of 53 months. VT-free survival after multiple procedures was 85.4% (41 of 48) at a median follow-up of 52 months. There were no major complications. Three patients died during the follow-up period from nonarrhythmic causes, including heart failure and cardiac surgery complication. CONCLUSION: While scar-related re-entry is the most common VT mechanism in patients with CHD, importantly, nonscar-related VT may also be present. In experienced tertiary care centers, ablation of both scar-related and nonscar-related VT in patients with CHD is safe, feasible, and effective over long-term follow-up.


Assuntos
Ablação por Cateter , Cardiopatias Congênitas/complicações , Frequência Cardíaca , Taquicardia Ventricular/cirurgia , Potenciais de Ação , Adulto , Antiarrítmicos/uso terapêutico , Ablação por Cateter/efeitos adversos , Colorado , Técnicas Eletrofisiológicas Cardíacas , Feminino , Seguimentos , Cardiopatias Congênitas/diagnóstico , Cardiopatias Congênitas/fisiopatologia , Cardiopatias Congênitas/cirurgia , Frequência Cardíaca/efeitos dos fármacos , Humanos , Masculino , Pessoa de Meia-Idade , Philadelphia , Intervalo Livre de Progressão , Recidiva , Reoperação , Estudos Retrospectivos , Fatores de Risco , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/fisiopatologia , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa