Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
Kardiologiia ; 64(3): 40-45, 2024 Mar 31.
Artigo em Russo, Inglês | MEDLINE | ID: mdl-38597761

RESUMO

AIM: Comparative analysis of the height of atherosclerotic plaques (AP) in the descending thoracic aorta (TA) according to two-dimensional (2D) and three-dimensional (3D) transesophageal echocardiography (TEE), and contrast-enhanced multislice computed tomography (MSCT). MATERIAL AND METHODS: The TA was examined using 2D, 3D TEE and contrast-enhanced MSCT in 34 patients (20 men and 14 women aged 68 [62; 71] years). AP heights were compared using the Bland-Altman method and the Spearman correlation analysis. This was a blinded comparative study which assessed the AP morphometry using each of the radiation modalities without knowing the results of the method being compared. RESULTS: 100 APs were examined in the descending TA. The mean height of all analyzed APs in the descending TA was 2.2 mm [2; 2.7] for 2D TEE, 3.1 mm [2.7; 3.55] for 3D TEE, and 3.05 mm [2.55; 3.55] for MSCT. The AP heights measured with 2D TEE was statistically significantly smaller than the heights of similar APs measured either with 3D TEE or MSCT. The mean difference (bias) was 0.88±0.34 mm between 2D and 3D TEE, and 0.83±0.41 mm between 2D TEE and MSCT. The correlation coefficients for the AP heights were r=0.87 (p<0.001) between 2D and 3D TEE and r=0.86 (p<0.001) between 2D TEE and MSCT. There were no differences in the height of similar APs between 3D TEE and MSCT. CONCLUSION: The three-dimensional reconstruction of AP in the TA by TEE is more accurate for quantitative assessment of AP than a two-dimensional study.


Assuntos
Ecocardiografia Tridimensional , Placa Aterosclerótica , Masculino , Humanos , Feminino , Aorta Torácica/diagnóstico por imagem , Placa Aterosclerótica/diagnóstico por imagem , Ecocardiografia , Ecocardiografia Transesofagiana
2.
Bull Exp Biol Med ; 174(4): 497-501, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36913090

RESUMO

We analyzed the associations of the mechanical strength of dilated ascending aorta wall (intraoperative samples from 30 patients with non-syndromic aneurysms) with tissue MMPs and the cytokine system. Some samples were stretched to break on an Instron 3343 testing machine and the tensile strength was calculated; others were homogenized and the concentrations of MMP-1, MMP-2, MMP-7, their inhibitors (TIMP-1 and TIMP-2), and pro- and anti-inflammatory cytokines were determined by ELISA. Direct correlations between aortic tensile strength and concentrations of IL-10 (r=0.46), TNFα (r=0.60), and vessel diameter (r=0.67) and an inverse correlation with patient's age (r=-0.59) were revealed. Compensatory mechanisms supporting the strength of the ascending aortic aneurysm are possible. No associations of MMP-1, MMP-7, TIMP-1, and TIMP-2 with tensile strength and aortic diameter were found.


Assuntos
Aneurisma da Aorta Ascendente , Aorta , Metaloproteinases da Matriz , Humanos , Citocinas , Metaloproteinase 1 da Matriz , Metaloproteinase 7 da Matriz , Inibidor Tecidual de Metaloproteinase-1 , Inibidor Tecidual de Metaloproteinase-2/genética , Inibidores Teciduais de Metaloproteinases , Aneurisma da Aorta Ascendente/patologia , Aorta/anatomia & histologia , Aorta/metabolismo , Aorta/patologia , Testes Mecânicos
3.
Kardiologiia ; 63(11): 64-72, 2023 Dec 05.
Artigo em Russo, Inglês | MEDLINE | ID: mdl-38088114

RESUMO

Aim      To study global aortic circumferential strain in normal conditions and in atherosclerosis of various grades and to determine its role in prediction of structural and functional disorders of the thoracic aorta (TA) and coronary atherosclerosis using 2D speckle-tracking transesophageal echocardiography.Material and methods  182 patients with typical or probable angina were examined. The control group consisted of 11 healthy volunteers. TA was visualized along its entire length. The height of each atheroma was measured, and the total number of plaques in the TA was determined. Five stages of TA atherosclerosis were identified. In the descending TA, the global peak systolic circumferential strain (GCS, %) and the global peak systolic circumferential strain normalized to pulse arterial pressure (PAP) (GCS / PAP∙100) were calculated. All patients underwent coronary angiography. The number of coronary arteries (CAs) with >50 % stenosis was determined, and the SYNTAX Score was calculated.Results TA atherosclerosis was not detected in the control group. Among 182 patients, stage 1-5 TA atherosclerosis was found in 23 (12.6 %), 103 (56.6 %), 43 (23.6 %), 7 (3.8 %), and 6 (3.4 %) cases respectively. GCS and GCS / PAD decreased as the ultrasound stage of TA atherosclerosis increased as compared with the control group: 9.2 % and 15.3 for the control group; stage 1, 5.6 % and 8.9 (p<0.001); stage 2, 4.1 % and 5.9 (p<0.001); stage 3, 4 % and 5.8 (p<0.001); stage 4, 3.7 % and 4.9 (p<0.01); and stage 5, 2.6 % and 3.3 (p<0.01), respectively. ROC analysis showed that GCS ≥5.9 % (area under the curve, AUC, 0.94±0.03; p<0.001) and GCS / PAD ≥11.4 (AUC, 0.97±0.02; p <0.001) were predictors of intact TA. Also, GCS ≤4.85 % (AUC, 0.82±0.04; p<0.001) and GCS / PAD ≤8.06 (AUC, 0.87±0.03; p<0.001) were predictors of hemodynamically significant TA atherosclerosis (stages 3-5). GCS ≤4.05 % (AUC, 0.62±0.04; p=0.007) and GCS / PAD ≤5.95 (AUC, 0.61±0.04; p=0.018) were predictors of hemodynamically significant (>50 %) stenosing atherosclerosis of at least one CA. Furthermore, GCS ≤3.75 % (AUC, 0.67±0.07; p=0.039) and GCS / PAD ≤5.15 (AUC, 0.64±0.07; p=0.045) were predictors of severe and advanced coronary atherosclerosis (SYNTAX Score ≥22).Conclusion      GCS and GCS / PAD are new diagnostic markers of structural and functional disorders of TA in atherosclerosis of various grades. GCS and GCS / PAD are independent predictors of high-grade TA atherosclerosis (stages 3-5) with GCS / PAD demonstrating the highest level of significance. GCS and GCS / PAD are non-invasive predictors of severe and advanced CA atherosclerosis.


Assuntos
Doenças da Aorta , Aterosclerose , Doença da Artéria Coronariana , Placa Aterosclerótica , Humanos , Doença da Artéria Coronariana/diagnóstico , Aorta Torácica/diagnóstico por imagem , Aterosclerose/diagnóstico , Ecocardiografia Transesofagiana , Angiografia Coronária , Placa Aterosclerótica/diagnóstico , Doenças da Aorta/diagnóstico , Doenças da Aorta/etiologia
4.
Khirurgiia (Mosk) ; (2): 67-74, 2022.
Artigo em Russo | MEDLINE | ID: mdl-35147003

RESUMO

The authors report a 76-year-old female with mega-aorta syndrome that was asymptomatic for a long time. The first symptoms appeared after ascending aorta enlargement up to 81 mm and compression of superior vena cava. The patient underwent frozen elephant trunk procedure. The authors demonstrate the possibilities of assessing the aortic strain by ECG-synchronized CT angiography and 2D transesophageal ultrasound with speckle tracking. Potential role of these methods in determining the type of aortic reconstruction is discussed.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Idoso , Dissecção Aórtica/cirurgia , Aorta/diagnóstico por imagem , Aorta/cirurgia , Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Prótese Vascular , Feminino , Humanos , Stents , Resultado do Tratamento , Veia Cava Superior
5.
Kardiologiia ; 61(7): 14-21, 2021 Jul 31.
Artigo em Russo, Inglês | MEDLINE | ID: mdl-34397337

RESUMO

Aim      To evaluate the predictive value of indexes of left ventricular mechanical dyssynchrony (MD) as determined by data of electrocardiogram (ECG)-gated myocardial perfusion scintigraphy (ECG-MPS) for prediction of the efficacy of resynchronization therapy (RT) in patients with chronic heart failure (CHF).Material and methods  This prospective study included 32 patients with nonischemic CHF and standard indications for RT. All patients underwent complete clinical an instrumental examination, including 24-h ECG monitoring and echocardiography (EchoCG). In order to evaluate the left ventricular (LV) myocardial perfusion, contractile function, and MD, myocardial perfusion scintigraphy was performed for all patients at rest prior to RT. In addition to the perfusion defect size at rest and hemodynamic parameters, LV MD was determined. The following indexes were used for analysis of dyssynchronization: phase standard deviation (PSD), phase histogram bandwidth (HBW), and phase histogram asymmetry and steepness. The treatment efficacy was evaluated by the clinical status of patients (clinical condition evaluation scale for CHF patient) and EchoCG at 6 months following RT. The criteria for a positive response to RT were an increase in LV ejection fraction (EF) by 5% and/or a decrease in the LV end-diastolic volume by 15% compared to preoperative values.Results According to ECG-MPS findings, all patients had scintigraphic signs of severe CHF with dilated LV cavity (end-diastolic volume, EDV 246 [217; 269] ml) and also of pronounced mechanical and electrical dyssynchrony. The values of mechanical dyssynchrony were PSD 53 [41; 61], HBW 176 [136; 202], asymmetry 1.62 [1.21; 1.89], and steepness 2.81 [1.21; 3.49]. The QRS duration was 165 [155; 175] msec. Furthermore, the LV perfusion was moderately impaired (perfusion defect size 4 [3; 10] %). Mean follow-up duration after implantation of the resynchronizing device was 6±1.7 mos. According to the selected criteria, 20 (63 %) patients were considered as responders and 12 (37 %) patients as non-responders. Before implantation of the cardiac synchronizing device, responders and non-responders differed only in LV MD (PSD 44 [35; 54] vs. 63 [58; 72]; p=0.0001); HBW 158 [118; 179] vs. 205 [199; 249]; p=0.0001; asymmetry 1.77 [1.62; 2.02] vs. 1.21 [0.93; 1.31]; p=0.0001; steepness 3.03 [2.60; 3.58] vs. 1.21 [0.19; 1.46]; p=0.0001), respectively. A one-factor logistic regression analysis showed that MD values were statistically significant predictors of a positive response to RT. A multi-factor logistic analysis of phase histogram steepness (odds ratio, OR 1.196; 95 % confidence interval, CI 1.04-1.37) and PSD (OR 0.67; 95 % CI 0.47-0.97) were identified as independent predictors for the response to RT. According to results of the ROC analysis, a PSD <55 and a phase histogram steepness >1.54 may predict the effectiveness of RT (AUC= 0.92; р=0.0001).Conclusion      LV MD parameters determined with ECG-MPS allow predicting the effectiveness of RT in patients with nonischemic CHF. In this patient group, high values of standard deviation and low values of phase histogram steepness were independent predictors for the absence of response to RT after 6 mos. of follow-up.


Assuntos
Terapia de Ressincronização Cardíaca , Cardiomiopatia Dilatada , Insuficiência Cardíaca , Disfunção Ventricular Esquerda , Cardiomiopatia Dilatada/terapia , Insuficiência Cardíaca/terapia , Humanos , Estudos Prospectivos , Disfunção Ventricular Esquerda/terapia , Função Ventricular Esquerda
6.
Kardiologiia ; 61(2): 47-53, 2021 Mar 04.
Artigo em Russo, Inglês | MEDLINE | ID: mdl-33734045

RESUMO

Aim      To study time-related changes in bone remodeling markers in patients with ischemic heart disease (IHD) associated with type 2 diabetes mellitus (DM) and disorders of carbohydrate metabolism (CM). Also, a possibility was studied of using these markers for evaluation of breast bone reparative regeneration in early and late postoperative periods following coronary bypass (CB).Materials and methods           This study included 28 patients with IHD and functional class II-III exertional angina after CB. Patients were divided into 2 groups based on the presence (group 1) and absence (group 2) of CM disorders. Contents of osteocalcin (OC), C-terminal telopeptide (CTTP) of type 1 collagen, deoxypyridinoline (DPD), and alkaline phosphatase bone isoenzyme (ALPBI) were measured by enzyme immunoassay on admission (Т1) and at early (Т2) and late (Т3) postoperative stages. Sternal scintigraphy with a radiopharmaceutical (RP) was performed at stage 3 following sternotomy.Results The content of OC and CTTP was reduced in group 1 compared to the values in the group without CM disorders (р<0.005) at stages Т1 and Т2. There were no significant intergroup differences in concentrations of ALPBI and DPD throughout the study. Time-related changes in OC, CTTP, and DPD had some intergroup differences: the increase in biomarkers was observed in group 1 considerably later, at stage Т3 (р<0.005), while in group 2, it was observed at stage T2 after sternotomy. Scintigraphy revealed significant intergroup differences in the intensity of RP accumulation in sternal tissue.Conclusion      The intergroup differences in the content of biomarkers evidenced a disbalance among processes of formation and resorption of bone tissue and delayed remodeling processes in patients with IHD associated with type 2 DM and CM disorders. The study confirmed significance of comprehensive evaluation of time-related changes in markers for bone tissue metabolism and sternal scintigraphy for diagnosis and evaluation of sternal reparative regeneration following sternotomy in patients with IHD associated with type 2 DM and disorders of CM metabolism.


Assuntos
Diabetes Mellitus Tipo 2 , Fosfatase Alcalina , Biomarcadores , Remodelação Óssea , Colágeno Tipo I , Diabetes Mellitus Tipo 2/complicações , Humanos
7.
Kardiologiia ; 59(5S): 65-68, 2019 Jun 20.
Artigo em Russo | MEDLINE | ID: mdl-31221077

RESUMO

This case report describes simultaneous approach that enables to replace the ascending aortic aneurysm complicated with atherosclerotic lesions of the descending aorta (the "shaggy aorta" syndrome) using frozen elephant trunk technique.


Assuntos
Aneurisma da Aorta Torácica , Aorta , Aorta Torácica , Aneurisma Aórtico , Implante de Prótese Vascular , Humanos , Resultado do Tratamento
8.
Angiol Sosud Khir ; 23(1): 82-86, 2017.
Artigo em Russo | MEDLINE | ID: mdl-28574041

RESUMO

Spinal ischaemia in patients after reconstruction of the thoracic aorta is referred to the category of the most severe postoperative complications, especially in hybrid interventions. The present study was aimed at assessing the risks for the development of spinal ischaemia in patients after implantation of the 'E-vita open plus' stent graft into the descending portion of the thoracic aorta during hybrid reconstruction. The 'E-vita open plus' hybrid stent graft (Jotec, Germany) was implanted to 18 patients presenting with various pathology of the thoracic aorta (dissection, aneurysms). All operations were carried out in the conditions of moderate hypothermia, circulatory arrest and antegrade perfusion of the brain through the brachiocephalic trunk. It was determined that the distal end of the stent graft was located at the level of Th7-Th12. In 12 (66.7%) cases the 'lower' edge of the stent graft was located at the level of thoracic vertebrae Th8-Th9. Before the operation the number of open pairs of intercostal arteries amounted to 10 [9, 11]. After the operation, the number of the open pairs of the segmental arteries amounted to 3 [1; 4], they were all in the lower thoracic portion; the above-located intercostal arteries were shut by the stent graft. In 17 (94.5%) cases in the early postoperative period there were no signs of spinal ischaemia. Only one (5.5%) patient was clinically diagnosed to have developed transient spinal ischaemia noted to disappear spontaneously within the first 24 hours. A conclusion was made that using the 'E-vita open plus' stent graft in the course of hybrid reconstruction of the thoracic aorta was accompanied by the minimal risk for spinal ischaemic complications. The level of the location of the distal edge of the stent graft is not the determining factor in the risks of spinal complications in of such similar operations.


Assuntos
Aorta Torácica , Aneurisma da Aorta Torácica , Complicações Pós-Operatórias , Retenção da Prótese/métodos , Isquemia do Cordão Espinal , Stents , Enxerto Vascular , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/patologia , Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/diagnóstico , Aneurisma da Aorta Torácica/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada Multidetectores/métodos , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/prevenção & controle , Medula Espinal/irrigação sanguínea , Medula Espinal/diagnóstico por imagem , Isquemia do Cordão Espinal/diagnóstico , Isquemia do Cordão Espinal/etiologia , Isquemia do Cordão Espinal/prevenção & controle , Resultado do Tratamento , Enxerto Vascular/efeitos adversos , Enxerto Vascular/instrumentação , Enxerto Vascular/métodos
9.
Angiol Sosud Khir ; 23(2): 59-63, 2017.
Artigo em Russo | MEDLINE | ID: mdl-28594797

RESUMO

Hybrid technologies appear to have been gaining ground in surgery of the thoracic aorta. The present study was aimed at assessing the immediate clinical outcomes of surgical treatment of diseases of the thoracic aorta by means of the 'E-vita open plus' hybrid stent graft. The 'E-vita open plus' hybrid stent graft was implanted to 18 patients. All operations were carried out in the conditions of moderate hypothermia. The brain was protected by unilateral cerebral perfusion through the brachiocephalic trunk. The duration of artificial circulation averagely amounted to 265.1 [214; 281] min., with the mean aortic cross-clamping time equalling 150.8 [121; 177] min., and circulatory arrest lasting 55 [47.5; 62.5] min. In one (5.5%) case resternotomy was performed for haemorrhage. Five (27.8%) patients required haemodialysis to perform for postoperative renal insufficiency. A further five (27.8%) patients were found to have transient impairment of cerebral circulation. One (5.5%) patient was diagnosed as having haemorrhage into the area of the 'old ischaemic focus', one (5.5%) patient developed transient spinal ischaemia spontaneously disappearing within the first 24 hours. There were no cases of cardiac complications. A conclusion was drawn that hybrid operations according to the 'frozen elephant trunk' technique yield satisfactory immediate clinical results of treatment in patients with thoracic aortic aneurysms and dissection.


Assuntos
Aorta Torácica , Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Complicações Pós-Operatórias , Dissecção Aórtica/diagnóstico , Dissecção Aórtica/cirurgia , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/patologia , Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/diagnóstico , Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada Multidetectores/métodos , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/terapia , Desenho de Prótese , Stents , Resultado do Tratamento
10.
Khirurgiia (Mosk) ; (5): 13-16, 2016.
Artigo em Russo | MEDLINE | ID: mdl-27271714

RESUMO

AIM: To evaluate surgical results in adults with aortic arch interruption. MATERIAL AND METHODS: Seven patients with aortic arch interruption were operated. Two of them (28.6%) underwent aortic arch repair using allograft, 4 (57.21%) - distal arch and proximal descending aortic replacement, 1 (14.3%) - supra-coronary ascending aortic, aortic arch and proximal descending aortic replacement. All operations were performed under moderate hypothermia (25 °Ð¡), circulatory arrest with unilateral cerabral perfusion 8-10 ml/kg/min via innominate artery and pressure 69.6±14.7 mm Hg in arterial. RESULTS: Cardiopulmonary bypass (CPB) time was 242±36.1 min, aortic cross-clamping - 110.7±40.4 min, circulatory arrest - 58.6±17.9 min. There were no cases of renal insufficiency, vascular lesion of brain and spinal cord, cardiac events. Resternotomy for bleeding was performed in 1 (14.3%) case. Sufficient descending aortic lumen was achieved in 100% according to CT postoperatively. Peak descending aortic pressure gradient after repair with allograft was 29±1.4 mm Hg, after aortic replaement - 10±4.2 mm Hg. Postoperative and in-hospital 30-day mortality was absent. CONCLUSION: Reconstructive surgery for aortic arch interruption in adults is effective approach with good clinical and hemodynamic results.


Assuntos
Aorta Torácica , Coartação Aórtica , Complicações Pós-Operatórias , Enxerto Vascular , Adulto , Aorta Torácica/anormalidades , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/fisiopatologia , Aorta Torácica/cirurgia , Coartação Aórtica/diagnóstico , Coartação Aórtica/fisiopatologia , Coartação Aórtica/cirurgia , Ponte Cardiopulmonar/métodos , Parada Circulatória Induzida por Hipotermia Profunda/métodos , Feminino , Hemodinâmica , Humanos , Masculino , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/cirurgia , Radiografia , Reoperação/métodos , Reoperação/estatística & dados numéricos , Estudos Retrospectivos , Índice de Gravidade de Doença , Sibéria , Esternotomia/estatística & dados numéricos , Resultado do Tratamento , Enxerto Vascular/efeitos adversos , Enxerto Vascular/métodos
11.
Angiol Sosud Khir ; 22(3): 66-73, 2016.
Artigo em Russo | MEDLINE | ID: mdl-27626252

RESUMO

BACKGROUND: The variety of pathology of the thoracic aorta supposes different approaches of surgical management, including the use of hybrid technologies. OBJECTIVE: To broaden a possible spectrum of indications for implantation of the "E-vita open plus" hybrid stent graft. RESULTS: Surgical treatment of thoracic aorta with the help of the "E-vita open plus" hybrid stent graft according to the "frozen elephant trunk" technique demonstrated satisfactory results in patients with various pathology: type A and B acute and chronic dissection according to the Stanford classification, as well as rare diseases (post-traumatic false aneurysm, complicated atherosclerosis of the thoracic aorta). CONCLUSION: The technology of "frosted elephant trunk" with implantation of the "E-vita open plus" hybrid stent graft in not limited by cases of acute aortic dissection, aortic aneurysmatic transformation and has wider indications for application. The use of this technology in cases of rare pathology of the thoracic aorta ("shaggy aorta" syndrome, posttraumatic false aneurysm) makes it possible to obtain satisfactory clinical results.


Assuntos
Aorta Torácica , Aneurisma da Aorta Torácica , Doenças da Aorta , Dissecção Aórtica , Implante de Prótese Vascular , Prótese Vascular , Complicações Pós-Operatórias/prevenção & controle , Dissecção Aórtica/diagnóstico , Dissecção Aórtica/cirurgia , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/patologia , Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/diagnóstico , Aneurisma da Aorta Torácica/cirurgia , Doenças da Aorta/diagnóstico , Doenças da Aorta/cirurgia , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/métodos , Angiografia por Tomografia Computadorizada/métodos , Feminino , Humanos , Complicações Intraoperatórias/prevenção & controle , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Sibéria , Resultado do Tratamento
12.
Khirurgiia (Mosk) ; (5): 19-23, 2015.
Artigo em Russo | MEDLINE | ID: mdl-26271318

RESUMO

MATERIAL AND METHODS: It is presented the results of cold-plasma sternotome application in 16 patients. Efficiency of this technique, its effect on sternal reparation as well as on the incidence of early and remote (4-5 months) postoperative wound complications were analyzed. Control group included 19 patients who underwent conventional sternotomy using high-temperature electrocoagulation and medical wax for hemostasis. Risk factors for sternal infection were comparable in both groups. Physical examination and computed tomography were performed in all patients to access incidence of complications and degree of bone tissueconsolidation respectively in postoperative period. RESULTS: It is shown that cold-plasma sternotomy leads to early inflammation resolution in oversplitting area and to reduction of wound complications incidence.


Assuntos
Coagulação com Plasma de Argônio/métodos , Gases em Plasma/uso terapêutico , Esternotomia , Deiscência da Ferida Operatória , Infecção da Ferida Cirúrgica , Idoso , Feminino , Hemostasia Cirúrgica/métodos , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Período Pós-Operatório , Federação Russa/epidemiologia , Esternotomia/efeitos adversos , Esternotomia/métodos , Deiscência da Ferida Operatória/diagnóstico , Deiscência da Ferida Operatória/epidemiologia , Deiscência da Ferida Operatória/prevenção & controle , Infecção da Ferida Cirúrgica/diagnóstico , Infecção da Ferida Cirúrgica/epidemiologia , Infecção da Ferida Cirúrgica/prevenção & controle , Tomografia Computadorizada por Raios X/métodos , Resultado do Tratamento , Cicatrização
14.
Sovrem Tekhnologii Med ; 13(6): 65-70, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-35265360

RESUMO

The aim of this study was to develop and test a technique for scintigraphic examination of the thoracic aorta, which allows for visualizing foci of inflammation. Materials and Methods: The study included 15 patients (median age - 61 [47; 73] years) with aortic dilatation more than 45 mm and thoracic aortic aneurysm who were candidates for surgical treatment. All patients underwent a chest scintigraphy with 99mTc-pyrophosphate 48 h before surgery to identify foci of inflammation in the aortic wall. The new technique included intravenous administration of 370 MBq of a radiopharmaceutical (RP), registration of scintigrams at 3 and 6 h after injection of RP in a tomographic mode combined with X-ray computed tomography. After the image reconstruction, subtraction of the later scintigrams from the early ones was performed, followed by analysis of the final images. The results of scintigraphy were compared with the histological data obtained from intraoperative samples of resected aorta. Results: According to the results of this novel scintigraphic technique, artifacts from the radioactivity of the vascular blood pool were eliminated and pathological RP uptake was identified in 5 (33.3±1.5%) out of 15 examined patients. The "focus/vessel lumen" ratio averaged at 1.47 [1.30; 1.48]. Histological examination of resected aorta samples confirmed the presence of chronic inflammation in 4 (26.7±1.3%) out of 15 patients. Parameters of diagnostic efficiency were: sensitivity - 100%, specificity - 91%, diagnostic accuracy - 93%. Conclusion: The method of scintigraphic diagnostics of inflammatory processes in the aorta using 99mTc-pyrophosphate, supplemented by subtraction of the late from the early images, makes it possible to eliminate artifacts from the radioactivity of the aortic blood pool and to reveal the pathological RP accumulation indicating the areas of inflammation in the aortic wall.


Assuntos
Difosfatos , Compostos Radiofarmacêuticos , Aorta/diagnóstico por imagem , Humanos , Inflamação/diagnóstico por imagem , Pessoa de Meia-Idade , Cintilografia
15.
Vestn Rentgenol Radiol ; (2): 58-65, 2015.
Artigo em Russo | MEDLINE | ID: mdl-26165008

RESUMO

As of now, the study of ventricular arrhythmias (VA) is of topical interest for modern arrhythmology and cardiology. These arrhythmias constitute about 30% of all the arrhythmias and have a diverse etiopathogenetic basis. Having no noticeable impact on a patient's quality of life, VA may cause ventricular fibrillation, severe circulatory disorders, and sudden cardiac death. Objective of this study--to compare the capabilities of radiation techniques for evaluating ventricular hemodynamics and contractility in patients with VA. A multitude of current radiodiagnostic methods, among which the most preferential technique cannot be set aside to reveal the causes of and to study hemodynamic disorders, is now used to evaluate ventricular hemodynamics and contractility in patients with VA. Each procedure has its usage features in a contingent of patients with arrhythmias.


Assuntos
Circulação Coronária/fisiologia , Diagnóstico por Imagem/métodos , Contração Miocárdica/fisiologia , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/fisiopatologia , Humanos , Radiografia , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa