Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Chest ; 130(1): 85-92, 2006 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-16840387

RESUMO

STUDY OBJECTIVES: Hypercapnic acidosis has antiinflammatory effects in animal models of acute lung injury (ALI) and improves ventilation-perfusion (V/Q) matching in normal lungs. The effect of hypercapnia on V/Q matching in ALI is conflicting. Hypercapnic acidosis produced by reduced tidal volumes (Vts) was associated with an increased shunt fraction (QS/QT) in patients with ALI compared with control subjects. Vt differences between groups make the assessment of hypercapnic acidosis on V/Q matching difficult. Adding CO2 to the inhaled gas allows the comparison of gas exchange under identical Vt conditions. We hypothesized the presence of hypercapnic acidosis from inspired carbon dioxide (ICD) would improve gas exchange in ALI and would be superior to that of low minute ventilation (LVe) produced by reduced respiratory rate, rather than Vt. DESIGN: University laboratory study of anesthetized New Zealand White rabbits. INTERVENTIONS: Assessment of V/Q relationships using the multiple inert gas elimination technique was performed in 10 saline solution-lavaged animals, which were ventilated with 6 mL/kg Vts and a positive end-expiratory pressure of 8 cm H2O. Each rabbit was studied while it was in eucapnia, followed by hypercapnia (Pa(CO2), 95 to 100 mm Hg) induced by LVe from decreased respiratory rate and by 10% ICD, in random order. MEASUREMENTS AND RESULTS: The Pa(O2) was greater in ICD and LVe compared to eucapnia, but no significant differences in alveolar-arterial oxygen pressure difference or Pa(O2)/fraction of inspired oxygen ratio occurred. LVe statistically reduced the mean V/Q distributions compared with ICD and eucapnia. Log SDs of ventilation and combined retention and excretion curves of the dispersion index were both increased during LVe, indicating the presence of unfavorable changes in ventilation distribution. Neither LVe nor ICD altered the QS/QT. CONCLUSIONS: LVe slightly impairs overall gas exchange and ventilation distribution, but does not increase QS/QT compared with eucapnia and ICD. While ICD does not significantly improve gas exchange, it may be superior to LVe in achieving the antiinflammatory effects of "therapeutic" hypercapnia, since it does not adversely alter gas exchange and has the potential to make the lung more uniformly acidotic.


Assuntos
Hipercapnia/metabolismo , Síndrome do Desconforto Respiratório/terapia , Animais , Dióxido de Carbono/metabolismo , Dióxido de Carbono/farmacologia , Modelos Animais de Doenças , Feminino , Masculino , Troca Gasosa Pulmonar , Coelhos , Respiração Artificial/métodos , Síndrome do Desconforto Respiratório/metabolismo , Relação Ventilação-Perfusão/fisiologia
2.
Chin J Physiol ; 49(2): 83-95, 2006 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-16830790

RESUMO

The effect of left lung atelectasis on the regional distribution of blood flow (Q), ventilation (V(A)) and gas exchange on the right lung ventilated with 100% O2 was studied in anesthetized dogs in the lateral decubitus posture. Q and V(A) were measured in 1.7 ml lung volume pieces using injected and aerosolized fluorescent microspheres, respectively. Hypoxic pulmonary vasoconstriction (HPV) in the atelectatic lung shifted flow to the ventilated lung. The increased flow in the ventilated lung ensured adequate gas exchange, compensating for the hypoxemia due to shunt contributed by the atelectatic lung. Left lung atelectasis caused a compensatory increase in the ventilated lung FRC that was smaller in the right (RLD) than left (LLD) lateral posture, the effect of lung compression by the atelectatic lung and mediastinal contents in the RLD posture. The O2 deficit measured by (A-a)DO2 increased with left lung atelectasis and was exacerbated in the LLD posture by 10 cm H2O PEEP, a result of increased shunt caused by a shift in Q from the ventilated to the atelectatic lung. The PEEP-induced O2 deficit was eliminated with inversion to the RLD posture.


Assuntos
Respiração com Pressão Positiva/métodos , Postura , Atelectasia Pulmonar/fisiopatologia , Atelectasia Pulmonar/terapia , Circulação Pulmonar , Ventilação Pulmonar , Volume de Ventilação Pulmonar , Adaptação Fisiológica , Animais , Velocidade do Fluxo Sanguíneo/fisiologia , Cães , Resultado do Tratamento
3.
J Appl Physiol (1985) ; 97(5): 1702-8, 2004 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-15220303

RESUMO

We studied the airway gas exchange properties of five inert gases with different blood solubilities in the lungs of anesthetized sheep. Animals were ventilated through a bifurcated endobronchial tube to allow independent ventilation and collection of exhaled gases from each lung. An aortic pouch at the origin of the bronchial artery was created to control perfusion and enable infusion of a solution of inert gases into the bronchial circulation. Occlusion of the left pulmonary artery prevented pulmonary perfusion of that lung so that gas exchange occurred predominantly via the bronchial circulation. Excretion from the bronchial circulation (defined as the partial pressure of gas in exhaled gas divided by the partial pressure of gas in bronchial arterial blood) increased with increasing gas solubility (ranging from a mean of 4.2 x 10(-5) for SF6 to 4.8 x 10(-2) for ether) and increasing bronchial blood flow. Excretion was inversely affected by molecular weight (MW), demonstrating a dependence on diffusion. Excretions of the higher MW gases, halothane (MW = 194) and SF6 (MW = 146), were depressed relative to excretion of the lower MW gases ethane, cyclopropane, and ether (MW = 30, 42, 74, respectively). All results were consistent with previous studies of gas exchange in the isolated in situ trachea.


Assuntos
Brônquios/fisiologia , Troca Gasosa Pulmonar , Animais , Brônquios/irrigação sanguínea , Artérias Brônquicas , Difusão , Expiração , Modelos Biológicos , Peso Molecular , Gases Nobres/administração & dosagem , Gases Nobres/sangue , Gases Nobres/química , Pressão Parcial , Fluxo Sanguíneo Regional , Ovinos , Solubilidade
4.
J Appl Physiol (1985) ; 92(2): 745-62, 2002 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-11796689

RESUMO

We aimed to assess the influence of lateral decubitus postures and positive end-expiratory pressure (PEEP) on the regional distribution of ventilation and perfusion. We measured regional ventilation (VA) and regional blood flow (Q) in six anesthetized, mechanically ventilated dogs in the left (LLD) and right lateral decubitus (RLD) postures with and without 10 cmH(2)O PEEP. Q was measured by use of intravenously injected 15-microm fluorescent microspheres, and VA was measured by aerosolized 1-microm fluorescent microspheres. Fluorescence was analyzed in lung pieces approximately 1.7 cm(3) in volume. Multiple linear regression analysis was used to evaluate three-dimensional spatial gradients of Q, VA, the ratio VA/Q, and regional PO(2) (Pr(O(2))) in both lungs. In the LLD posture, a gravity-dependent vertical gradient in Q was observed in both lungs in conjunction with a reduced blood flow and Pr(O(2)) to the dependent left lung. Change from the LLD to the RLD or 10 cmH(2)O PEEP increased local VA/Q and Pr(O(2)) in the left lung and minimized any role of hypoxia. The greatest reduction in individual lung volume occurred to the left lung in the LLD posture. We conclude that lung distortion caused by the weight of the heart and abdomen is greater in the LLD posture and influences both Q and VA, and ultimately gas exchange. In this respect, the smaller left lung was the most susceptible to impaired gas exchange in the LLD posture.


Assuntos
Postura/fisiologia , Relação Ventilação-Perfusão , Aerossóis , Animais , Cães , Feminino , Fluorescência , Injeções Intravenosas , Pulmão/fisiologia , Masculino , Microesferas , Oxigênio/sangue , Pressão Parcial , Respiração com Pressão Positiva , Circulação Pulmonar , Troca Gasosa Pulmonar , Respiração Artificial
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa