Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 61
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Opt Express ; 29(22): 35172-35181, 2021 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-34808956

RESUMO

Micro-lens array is a great example of bio-mimetic technology which was inspired by compound eyes found in insects and is used in lasers, optical communication, and 3D imaging. In this study, a micro-lens array was fabricated from cyclic olefin copolymer using a cost-effective method: compression molding and thermal reflow. Also, a light screen was installed between lenses to reduce the optical interference for clearer individual images. Cyclic olefin copolymer-based micro-lens array showed good optical results under a standard optical microscope. By placing the fabricated micro-lens array directly on an image sensor, it was observed that the light screen shows significant improvement in image quality. Also, the point spread function was analyzed to confirm the optical performance and the effectiveness of the micro-lens array with the light screen installed.


Assuntos
Alcenos/química , Biomimética/instrumentação , Lentes , Luz , Óptica e Fotônica/instrumentação , Análise Custo-Benefício , Desenho de Equipamento , Óptica e Fotônica/economia
2.
Opt Express ; 29(24): 39214-39226, 2021 Nov 22.
Artigo em Inglês | MEDLINE | ID: mdl-34809290

RESUMO

Micro-lens array, an artificial compound eye vision system, provides a wide field of view and multi-perspective view. However, it has not been adopted as a computer vision application due to its limited visible range and high optical interference. In this research, a novel fabrication method for the flexible polydimethylsiloxane micro-lens array with a polytetrafluoroethylene light screen-aperture integrated layer was established by the simple protrusion method. The integrated layer provided longer visible range by one meter while maintaining the wide field-of-view of 100 °. The resulting images were used for obtaining depth information of a target as an example and for analyzing the rectangular and hexagonal arrangements of the micro-lenses for the future applications. With the improved visual range, wide field-of-view and flexibility, the fabricated micro-lens array can be applied to the small and curved CMOS image sensors in the future.


Assuntos
Biomimética/instrumentação , Técnicas Biossensoriais/instrumentação , Olho Composto de Artrópodes/fisiologia , Dimetilpolisiloxanos/química , Cristalino/fisiologia , Politetrafluoretileno/química , Animais , Biomimética/métodos , Desenho de Equipamento , Luz
3.
Neurosurg Focus ; 49(1): E10, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32610289

RESUMO

OBJECTIVE: The authors' goal was to study avian motor brain mapping via wireless stimulation to induce certain behaviors. In this paper, the authors propose an electrode design that is suitable for avian brain stimulation as well as a stereotactic implant procedure for the proposed electrode. METHODS: An appropriate breed for avian brain study was chosen. A fully implantable remote-controlled electrical stimulation system was inserted to minimize discomfort. A suitable electrode design and stereotactic surgery method based on the electrode design were investigated. RESULTS: Using a wireless stimulation system, flapping and rotation behaviors were induced by stimulating the ventral part of the nucleus intercollicularis and formatio reticularis medialis mesencephali both on the ground and during flight. CONCLUSIONS: The authors were able to implant the entire brain stimulation system inside the avian body without any surgical complications. Postoperative observations suggested that the bird did not find the implant uncomfortable.


Assuntos
Encéfalo/fisiologia , Encéfalo/cirurgia , Estimulação Encefálica Profunda , Técnicas Estereotáxicas , Animais , Aves , Mapeamento Encefálico/métodos , Estimulação Encefálica Profunda/métodos , Estimulação Elétrica/métodos , Eletrodos Implantados , Humanos , Imageamento Tridimensional
4.
Graefes Arch Clin Exp Ophthalmol ; 257(3): 645-650, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30661115

RESUMO

PURPOSE: To validate the effectiveness of the selective wavelength filter analysis with infrared photographs for diagnosing small-angle esotropia in children under age 4. METHODS: This is a retrospective, observational, case-control study. A total of 83 esotropes with an esodeviation of ≤ 16 prism diopters (PD) and 75 orthotropic controls under 4 years of age were included. Full-face infrared photographs were taken with a selective wavelength filter in front of either eye. The angles of esodeviation on photographs were measured with the three-dimensional Strabismus Photo Analyzer. The alternate prism and cover test or the Krimsky test were repeatedly performed to measure ocular alignment. RESULTS: The testability of infrared photographs using selective wavelength filters in children under 4 years of age was 85.6%. The mean angle of esodeviation was 11.3 ± 4.0 PD by manual measurements and 11.5 ± 4.4 PD by the infrared photograph analysis. Manual measurements and the infrared photograph analysis showed a strong positive correlation (R = 0.815, P < 0.001). The sensitivity and specificity of the infrared photograph analysis for detecting small-angle esotropia were 95.2% and 77.9%, respectively, with a cutoff value of 4.0 PD. CONCLUSIONS: The automated infrared photograph analysis was simple and effective for diagnosing small-angle esotropia in young children.


Assuntos
Técnicas de Diagnóstico Oftalmológico , Esotropia/diagnóstico , Raios Infravermelhos , Músculos Oculomotores/diagnóstico por imagem , Fotografação/métodos , Visão Binocular , Estudos de Casos e Controles , Pré-Escolar , Esotropia/fisiopatologia , Feminino , Humanos , Lactente , Masculino , Reprodutibilidade dos Testes , Estudos Retrospectivos
5.
Sensors (Basel) ; 19(7)2019 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-30979050

RESUMO

Blood pressure (BP) is a physiological parameter reflecting hemodynamic factors and is crucial in evaluating cardiovascular disease and its prognosis. In the present study, the reliability of a non-invasive and continuous BP measurement using a three-axis tactile force sensor was verified. All the data were collected every 2 min for the short-term experiment, and every 10 min for the long-term experiment. In addition, the effects on the BP measurement of external physical factors such as the tension to the radial artery on applying the device and wrist circumference were evaluated. A high correlation between the measured BP with the proposed system and with the cuff-based non-invasive blood pressure, and reproducibility, were demonstrated. All data satisfied the Association for the Advancement of Medical Instrumentation criteria. The external physical factors did not affect the measurement results. In addition to previous research indicating the high reliability of the arterial pulse waveforms, the present results have demonstrated the reliability of numerical BP values, and this implies that the three-axis force sensor can be used as a patient monitoring device.


Assuntos
Técnicas Biossensoriais , Monitores de Pressão Arterial , Pressão Sanguínea/fisiologia , Tato/fisiologia , Adulto , Determinação da Pressão Arterial , Feminino , Voluntários Saudáveis , Humanos , Masculino , Pessoa de Meia-Idade , Artéria Radial/fisiologia , Punho/fisiologia
6.
Sensors (Basel) ; 18(7)2018 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-29932163

RESUMO

In nature, arthropods have evolved to utilize a multiaperture vision system with a micro-optical structure which has advantages, such as compact size and wide-angle view, compared to that of a single-aperture vision system. In this paper, we present a multiaperture imaging system using a microlens array fabricated by a patterned-layer integrating soft lithography (PLISL) process which is based on a molding technique that can transfer three-dimensional structures and a gold screening layer simultaneously. The imaging system consists of a microlens array, a lens-adjusting jig, and a conventional (charge-coupled device) CCD image sensor. The microlens array has a light screening layer patterned among all the microlenses by the PLISL process to prevent light interference. The three-dimensionally printed jig adjusts the microlens array on the conventional CCD sensor for the focused image. The manufactured imaging system has a thin optic system and a large field-of-view of 100 degrees. The developed imaging system takes multiple images at once. To show its possible applications, multiple depth plane images were reconstructed based on the taken subimages with a single shot.

7.
Sensors (Basel) ; 15(6): 14345-55, 2015 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-26091397

RESUMO

In order to provide high-quality visual information to patients who have implanted retinal prosthetic devices, the number of microelectrodes should be large. As the number of microelectrodes is increased, the dimensions of each microelectrode must be decreased, which in turn results in an increased microelectrode interface impedance and decreased injection current dynamic range. In order to improve the trade-off envelope between the number of microelectrodes and the current injection characteristics, a 3D microelectrode structure can be used as an alternative. In this paper, the electrical characteristics of 2D and 3D Au microelectrodes were investigated. In order to examine the effects of the structural difference, 2D and 3D Au microelectrodes with different base areas but similar effective surface areas were fabricated and evaluated. Interface impedances were measured and similar dynamic ranges were obtained for both 2D and 3D Au microelectrodes. These results indicate that more electrodes can be implemented in the same area if 3D designs are used. Furthermore, the 3D Au microelectrodes showed substantially enhanced electrical durability characteristics against over-injected stimulation currents, withstanding electrical currents that are much larger than the limit measured for 2D microelectrodes of similar area. This enhanced electrical durability property of 3D Au microelectrodes is a new finding in microelectrode research, and makes 3D microelectrodes very desirable devices.


Assuntos
Ouro/química , Microtecnologia/instrumentação , Próteses Visuais , Impedância Elétrica , Microeletrodos , Desenho de Prótese
8.
IEEE Trans Biomed Eng ; 71(1): 3-13, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37216261

RESUMO

OBJECTIVE: In this paper, the fabrication of perfluoro-alkoxy alkane (PFA) film-based planar neural electrodes was proposed. METHODS: The fabrication of PFA-based electrodes started with cleaning of PFA film. The argon plasma pretreatment was performed on the PFA film surface and attached to a dummy silicon wafer. Metal layers were deposited and patterned using the standard Micro Electro Mechanical Systems (MEMS) process. Electrode-sites and pads were opened using reactive ion etching (RIE). Lastly, the electrode patterned PFA substrate film was thermally laminated with the other bare PFA film. Electrical-physical evaluation tests were conducted along with in vitro tests, ex vivo tests and soak tests to evaluate the electrode performance and biocompatibility. RESULTS: The electrical and physical performance of PFA-based electrodes had better performances compared to other biocompatible polymer-based electrodes. Also, the biocompatibility and longevity were verified by cytotoxicity test, elution test, and accelerated life test. CONCLUSION: The PFA film-based planar neural electrode fabrication was established and evaluated. The PFA based electrodes showed excellent benefits such as long-term reliability, low water absorption rate, and flexibility using the neural electrode. SIGNIFICANCE: For implantable neural electrodes, hermetic sealing is required for in vivo durability. PFA fulfilled a low water absorption rate with relatively low Young's modulus to increase the longevity and biocompatibility of the devices.


Assuntos
Eletricidade , Polímeros , Reprodutibilidade dos Testes , Eletrodos Implantados , Eletrodos , Água
9.
Sci Rep ; 14(1): 4207, 2024 02 20.
Artigo em Inglês | MEDLINE | ID: mdl-38378728

RESUMO

We conducted a prospective study to evaluate the efficacy of simulation-based education using a three-dimensional (3D)-printed schematic eye model in improving the retinoscopy refraction skills of medical students. A schematic eye model was printed using a fused deposition modeling-based 3D printer. Twenty medical students randomized into 3D (n = 10) and control (n = 10) groups received a 1-h lecture on the principles and methods of manifest refraction and were shown how to use the retinoscope and sciascope bars. The 3D group additionally attended a tutorial on the schematic eye. Both groups performed refractive examinations on four eyes of volunteer patients, and the results were recorded as a baseline. Instructor feedback and refraction practice was provided with the 3D group or with control group. To account for subject fatigue, patients spent no more than 8 min on the examination. After a 1-h break to allow for fatigue and familiarity, refraction tests were repeated on four randomly selected eyes of patients. Students' refraction readings were compared with the autorefractor values using a spherical equivalent value and blur strength. All participants measured the time required to complete the refraction test and reported their subjective confidence in the results of each refraction test. Refractive errors before and after training did not differ between the control and 3D groups, with a significant improvement in errors observed in both groups (p = 0.005 and 0.008, respectively). The time to complete refraction before and after training did not differ between the two groups, both of which showed a significant reduction in time (p = 0.005 and 0.028, respectively). Pre- and post-training confidence scores for the accuracy of each refraction on a 10-point Likert scale were not significantly different. However, when comparing score changes between pre- and post-training, only the control group showed a significant increase in confidence (p = 0.005). Tests for the non-inferiority of refractive errors after training indicated that the 3D group was non-inferior to the control group. In conclusion, training in retinoscopy refraction skills using a 3D-printed eye model resulted in significant improvement in accuracy and speed compared to practice with real patients. Except for better confidence in the control group, schematic eye model training was not inferior to practice with real patients.


Assuntos
Erros de Refração , Estudantes de Medicina , Humanos , Retinoscopia , Estudos Prospectivos , Refração Ocular , Erros de Refração/diagnóstico , Fadiga , Impressão Tridimensional
10.
Biomed Eng Lett ; 14(2): 267-278, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38374899

RESUMO

This research was conducted to apply polyimide tape, which has the advantages of low price ans strong adhesive strength, to the neural electrode process. In addition, to maximize the low-cost characteristics, a fabrication process based on UV laser patterning rather than a photolithography process was introduced. The fabrication process started by attaching the gold sheet on the conductive double-sided tape without being torn or crushed. Then, the gold sheet and the double-sided tape were patterned together using UV laser. The patterned layer was transferred to the single-side polyimide tape. For insulation layer, electrode site opened single-sided polyimide tape was prepared. Polydimethylsiloxane was used as an adhesion layer, and alignment between electrode sites and opening sites was processed manually. The minimum line width achieved through the proposed fabrication process was approximately 100 µm, and the sheet resistance of the conductive layer was 0.635 Ω/sq. Measured cathodal charge storage capacity was 0.72 mC/cm2 and impedance at 1 kHz was 4.07 kΩ/cm2. Validation of fabricated electrode was confirmed by conducting 30 days accelerated soak test, flexibility test, adhesion test and ex vivo stimulation test. The novel flexible neural electrodes based on single-sided polyimide tape and UV laser patterned gold sheet was fabricated successfully. Conventional neural electrode fabrication processes based on polyimide substrate has a disadvantages such as long fabrication time, expensive costs, and probability of delamination between layers. However, the novel fabrication process which we introduced can overcome many shortcomings of existing processes, and offers great advantages such as simplicity of fabrication, inexpensiveness, flexibility and long-term reliability.

11.
Artigo em Inglês | MEDLINE | ID: mdl-38083557

RESUMO

Feature importance methods are widely used in machine learning analysis for medical datasets as both primary and subsidiary tools. These methods aid in selecting biomarkers or markers indicating target diseases, and can provide valuable insight into the mechanism of a disease. However, the simple listing of features with their corresponding importance rank is not sufficient in determining the statistical significance of these features. In this paper, we propose a simple method for evaluating the statistical significance of feature importance values and selecting the optimal number of biomarkers. We demonstrate the application of this method using a public open dataset on heart failure.Clinical Relevance- In order for important indicators to be clinically useful, their statistical significance must be defined. By proposing a simple method for calculating statistical significance, this paper enables clinicians to select a group of biomarkers based on their feature importance in a machine learning model. This approach improves the accuracy and effectiveness of clinical decision-making, leading to more precise diagnosis, treatment, and management of various medical conditions.


Assuntos
Aprendizado de Máquina , Biomarcadores
12.
Artigo em Inglês | MEDLINE | ID: mdl-38082955

RESUMO

OBJECTIVES: In this paper, to figure out the reliability of copper wire wound coil in an in vitro environment, performance deterioration and copper ion elution of coil was investigated using accelerated tests. METHODS: Bare coils with enamel coating and parylene-C coated coils were immersed into the 75-degree Celsius phosphate-buffered saline for accelerated tests. Performance and elution of the copper ion were investigated using proper equipment. RESULTS: The parylene-C coating with a thickness of several um effectively depress the performance degradation and the elution of the copper ion. However, it has not reached a perfect level and research on additional packaging methods is needed. SIGNIFICANCE: Coil for wireless power and data transfer is an important element in the design of implantable devices. Copper is the most widely used material for the design of coils in general. However, because of its cytotoxicity and high reactivity with water, the packaging capabilities should be investigated closely. In this paper, a method for evaluating the packaging performance when the coil is coated with parylene-C and the results are presented.


Assuntos
Cobre , Próteses e Implantes , Cobre/toxicidade , Reprodutibilidade dos Testes , Polímeros
13.
Artigo em Inglês | MEDLINE | ID: mdl-38083392

RESUMO

In this work, a fabrication process for implantable electrodes using a Cyclic Olefin Copolymer (COC) substrate and a SU-8 passivation layer was presented. COC and SU-8 were shown to be suitable for implantable neural electrodes due to their biocompatibility, chemical resistance, and thermal stability. The electrodes were successfully patterned on the COC film, and the SU-8 passivation layer was coated while maintaining site-opened via photolithography. The photocrosslinking lamination of the substrate and passivation layer was used to produce electrodes with fine line widths of 20um without applying heat.


Assuntos
Cicloparafinas , Microeletrodos , Eletrodos Implantados
14.
Artigo em Inglês | MEDLINE | ID: mdl-38083749

RESUMO

The use of smartwatches has become increasingly common with the release of major products such as the Galaxy Watch by Samsung and the Apple Watch by Apple. The common aim of smartwatches is to target the healthcare market with a wearable, physically-attached device, with blood pressure at the core. As blood pressure is an important biomarker for cardiovascular-related diseases, it is a necessary index to inspect in hospitals when checking an individual's health state. Smartwatches are expected to provide a cuff-less, non-invasive method of estimating blood pressure. However, not many experiments have been conducted on blood pressure datasets obtained from smartwatches. Smartwatches are unique compared to other devices because they require "calibration" to sustain their accuracy.In this paper, we investigate the difference between before and after calibration to better understand the calibration pattern. Not only do we seek to understand the demographic differences in calibration, but we also analyze the possible variables that influence calibration differences. Our results show that hypertensive patients are more prone to high calibration differences, which implies that the calibration period should be adjusted by considering the average blood pressure of users.Clinical Relevance- This paper investigates the possibility for daily BP measurement to be used as clinical data while suggesting proper method to sustain its validity.


Assuntos
Hipertensão , Dispositivos Eletrônicos Vestíveis , Humanos , Calibragem , Pressão Sanguínea/fisiologia , Determinação da Pressão Arterial , Hipertensão/diagnóstico
15.
Artigo em Inglês | MEDLINE | ID: mdl-38083447

RESUMO

A retinal prosthesis is a device that can provide artificial vision to people who have lost their sight from certain retinal disorder. Because the device needs to be inserted into the body, high flexibility and reliability is required. Recently, devices using thermoplastic polymers such as LCP and COC as substrates have been studied. Being a highly functional integrated device, retinal prosthesis poses many design challenges. Among them, the stimulation chip embedding can be a particularly important task. Although it is common to use a wire bonding method for chip embedding, there are several limitations that are difficult to apply to implantable device. In this investigation, a novel approach is developed for high spaceefficient electrical connections and perform reliable encapsulation of integrated circuits to replace wire bonding. Since designing and manufacturing the stimulator chip used in retinal prosthesis requires non-negligible cost, a silicon die with the identical shape was selected as a substitute for testing purposes.


Assuntos
Cicloparafinas , Doenças Retinianas , Próteses Visuais , Humanos , Reprodutibilidade dos Testes , Polímeros
16.
Clin Hypertens ; 29(1): 15, 2023 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-37259165

RESUMO

BACKGROUND: Cuffless blood pressure (BP) measurement, enabled by recent advances in wearable devices, allows for BP monitoring in daily life. This study aims to evaluate the feasibility, cresdence, and usefulness of cuffless BP monitoring through a population survey. METHODS: During the "Daily BP Measurement with Your Galaxy Watch" campaign held by the Korean Society of Hypertension, participants were asked to share their experiences with cuffless BP measurement using a smartwatch application through an online survey. The questionnaire included questions about age, underlying medical conditions, smartwatch utilization, experience with BP calibration, the reliability of BP values measured by a smartwatch, and willingness to use the BP monitoring function in the future. RESULTS: A total of 1071 participants responded to the survey. The largest age group (decile) was 50-59 years old (33.3%), followed by 40-49 years old (29.9%). Although nearly half of the participants (47.5%) had no chronic diseases, 40.1% reported having hypertension. BP monitoring was the most frequently utilized smartwatch function (95.8%), followed by heart rate measurement (87.1%). 31.8% of participants reported that BP values measured by the smartphone application were "very accurate and helpful," while 63.5% rated them as "slightly lower (44.4%)" or "higher (19.1%)" compared to the standard home BP monitoring device. 93% of the participants reported utilizing the BP monitoring function at least once a week. Regarding the BP calibration process, most participants (93.9%) calibrated the BP measurement application themselves, and 50.8% rated the difficulty level as "very easy." CONCLUSION: Cuffless BP measurement using a smartwatch application was feasible in the general population, including the self-calibration process. However, the satisfaction level in terms of accuracy is still modest, indicating a need for further development.

17.
Hypertens Res ; 46(4): 922-931, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36781979

RESUMO

Cuffless wearable devices are currently being developed for long-term monitoring of blood pressure (BP) in patients with hypertension and in apparently healthy people. This study evaluated the feasibility and measurement stability of smartwatch-based cuffless BP monitoring in real-world conditions. Users of the first smartwatch-based cuffless BP monitor approved in Korea (Samsung Galaxy Watch) were invited to upload their data from using the device for 4 weeks post calibration. A total of 760 participants (mean age 43.7 ± 11.9, 80.3% men) provided 35,797 BP readings (average monitoring 22 ± 4 days [SD]; average readings 47 ± 42 per participant [median 36]). Each participant obtained 1.5 ± 1.3 readings/day and 19.7% of the participants obtained measurements every day. BP showed considerable variability, mainly depending on the day and time of the measurement. There was a trend towards higher BP levels on Mondays than on other days of the week and on workdays than in weekends. BP readings taken between 00:00 and 04:00 tended to be the lowest, whereas those between 12:00 and 16:00 the highest. The average pre-post calibration error for systolic BP (difference in 7-day BP before and after calibration), was 6.8 ± 5.6 mmHg, and was increased with higher systolic BP levels before calibration. Smartwatch-based cuffless BP monitoring is feasible for out-of-office monitoring in the real-world setting. The stability of BP measurement post calibration and the standardization and optimal time interval for recalibration need further investigation.


Assuntos
Determinação da Pressão Arterial , Hipertensão , Masculino , Humanos , Feminino , Pressão Sanguínea/fisiologia , Estudos de Viabilidade , Hipertensão/diagnóstico , Monitores de Pressão Arterial
18.
Biofabrication ; 15(4)2023 09 22.
Artigo em Inglês | MEDLINE | ID: mdl-37659401

RESUMO

One of the most promising techniques for treating severe peripheral artery disease is the use of cellular tissue-engineered vascular grafts (TEVGs). This study proposes an inverse-gravity (IG) extrusion technique for creating long double-layered cellular TEVGs with diameters over 3 mm. A three-layered coaxial laminar hydrogel flow in an 8 mm-diameter pipe was realised simply by changing the extrusion direction of the hydrogel from being aligned with the direction of gravity to against it. This technique produced an extruded mixture of human aortic smooth muscle cells (HASMCs) and type-I collagen as a tubular structure with an inner diameter of 3.5 mm. After a 21 day maturation period, the maximal burst pressure, longitudinal breaking force, and circumferential breaking force of the HASMC TEVG were 416 mmHg, 0.69 N, and 0.89 N, respectively. The HASMC TEVG was endothelialised with human umbilical vein endothelial cells to form a tunica intima that simulated human vessels. Besides subcutaneous implantability on mice, the double-layered blood vessels showed a considerably lower adherence of platelets and red blood cells once exposed to heparinised mouse blood and were considered nonhaemolytic. The proposed IG extrusion technique can be applied in various fields requiring multilayered materials with large diameters.


Assuntos
Aorta , Plaquetas , Humanos , Animais , Camundongos , Prótese Vascular , Células Endoteliais da Veia Umbilical Humana , Hidrogéis
19.
J Neural Eng ; 19(6)2022 12 02.
Artigo em Inglês | MEDLINE | ID: mdl-36374010

RESUMO

Objective.Neurostimulator is one of the most important part in artificial retina design. In this paper, we discuss the main challenges in the design of application-specific integrated circuit for high-resolution artificial retina and suggest corresponding solutions.Approach. Problems in the design of the neurostimulator for the existing artificial retina have not been solved yet are analyzed and solutions are presented. For verification of the solutions, mathematical proof, MATLAB and Ansys simulations are used.Main results. The drawbacks of resorting to a high-voltage complementary metal oxide semiconductor (CMOS) process to deal with the large voltage compliance demanded by the stimulator output stage are pointed out, and an alternative approach based on a circuit that switches the voltage of the common reference electrode is proposed to overcome. The necessity of an active discharge circuit to remove the residual charge of electrodes caused by an unbalanced stimulus is investigated. We present a circuit analysis showing that the use of a passive discharge circuit is sufficient to suppress problematic direct current in most situations. Finally, possible restrictions on input and output (I/O) count are investigated by estimating the resistive-capacitive delay caused by the interconnection between the I/O pad and the microelectrode array.Significance. The results of this paper clarified the problems currently faced by neurostimulator design for the artificial retina. Through the solutions presented in this study, circuits with more competitiveness in power and area consumption can be designed.


Assuntos
Retina , Microeletrodos , Desenho de Prótese , Desenho de Equipamento
20.
Annu Int Conf IEEE Eng Med Biol Soc ; 2022: 4261-4264, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-36085928

RESUMO

In this paper, simulation data and heat generation due to electromagnetic from spiral planar pair of coils for arti-ficial retinal implant were analyzed by COMSOL Multiphysics. Planar spiral outer and inner coils for an implantable artificial retina were designed and analyzed. The whole geometry was designed in a transplant situation. The parameters of the coil were set within the design limits due to the limitations of im-plant space. The inductance for the coil and the thermal change due to the electromagnetic force generated in the inductively coupled coil were calculated. Analysis of heat transfer in a biological model showed that the maximum heat did not exceed the internal tissue damage temperature. The results showed that a pair of coils designed for artificial retinas can be implanted in vivo without destruction of body tissues.


Assuntos
Calefação , Próteses e Implantes , Fenômenos Eletromagnéticos , Desenho de Equipamento , Retina
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa