Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 75
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
BMC Oral Health ; 20(1): 204, 2020 07 11.
Artigo em Inglês | MEDLINE | ID: mdl-32652980

RESUMO

BACKGROUND: To systematically review the epidemiologic relationship between periodontitis and type 2 diabetes mellitus (T2DM). METHODS: Four electronic databases were searched up until December 2018. The manual search included the reference lists of the included studies and relevant journals. Observational studies evaluating the relationship between T2DM and periodontitis were included. Meta-analyses were conducted using STATA. RESULTS: A total of 53 observational studies were included. The Adjusted T2DM prevalence was significantly higher in periodontitis patients (OR = 4.04, p = 0.000), and vice versa (OR = 1.58, p = 0.000). T2DM patients had significantly worse periodontal status, as reflected in a 0.61 mm deeper periodontal pocket, a 0.89 mm higher attachment loss and approximately 2 more lost teeth (all p = 0.000), than those without T2DM. The results of the cohort studies found that T2DM could elevate the risk of developing periodontitis by 34% (p = 0.002). The glycemic control of T2DM patients might result in different periodontitis outcomes. Severe periodontitis increased the incidence of T2DM by 53% (p = 0.000), and this result was stable. In contrast, the impact of mild periodontitis on T2DM incidence (RR = 1.28, p = 0.007) was less robust. CONCLUSIONS: There is an evident bidirectional relationship between T2DM and periodontitis. Further well-designed cohort studies are needed to confirm this finding. Our results suggest that both dentists and physicians need to be aware of the strong connection between periodontitis and T2DM. Controlling these two diseases might help prevent each other's incidence.


Assuntos
Diabetes Mellitus Tipo 2 , Periodontite , Diabetes Mellitus Tipo 2/complicações , Diabetes Mellitus Tipo 2/epidemiologia , Humanos , Bolsa Periodontal , Periodontite/complicações , Periodontite/epidemiologia
2.
Biomed Microdevices ; 21(4): 92, 2019 11 04.
Artigo em Inglês | MEDLINE | ID: mdl-31686233

RESUMO

Primary open-angle glaucoma is a progressive disease affecting nearly 60 million people worldwide which, if left untreated, can lead to optic nerve head damage and complete loss of sight. Current interventions include: pharmaceutical drops, laser surgery, shunts, and bleb; however, these methods provide insufficient long-term efficacy in intraocular pressure management. We developed a semi-permanent, implantable transcorneal duct as a new aid in the treatment of this disease. The duct, composed of an intracorneal stabilizing washer and hollow screw, creates an interface between the anterior chamber and the external environment, allowing for the outflow of excess aqueous humor. We discuss the fluid mechanics behind designing and implementing a filter material capable of preventing the ingress of bacteria and viruses while modifying aqueous humor outflow resistances to pre-glaucomatous levels, finding the effective radius of such a material to be 10.44 µm. After performing surgical implantation in four rabbit eyes, subsequent testing showed successful integration between the screw and washer. Colored saline injections highlighted fluid flow progression out of the eye through the duct, suggesting that the device may be a viable approach to treating high intraocular pressure created by open-angle glaucoma.


Assuntos
Córnea , Glaucoma de Ângulo Aberto/cirurgia , Procedimentos Cirúrgicos Oftalmológicos/instrumentação , Animais , Humor Aquoso/metabolismo , Glaucoma de Ângulo Aberto/metabolismo , Glaucoma de Ângulo Aberto/fisiopatologia , Pressão Intraocular , Coelhos
3.
J Appl Clin Med Phys ; 20(5): 84-98, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30977297

RESUMO

PURPOSE: To measure dosimetric and spatial accuracy of stereotactic radiosurgery (SRS) delivered to targets as small as the trigeminal nerve (TN) using a standard external beam treatment planning system (TPS) and multileaf collimator-(MLC) equipped linear accelerator without cones or other special attachments or modifications. METHODS: Dosimetric performance was assessed by comparing computed dose distributions to film measurements. Comparisons included the γ-index, beam profiles, isodose lines, maximum dose, and spatial accuracy. Initially, single static 360° arcs of MLC-shaped fields ranging from 1.6 × 5 to 30 × 30 mm2 were planned and delivered to an in-house built block phantom having approximate dimensions of a human head. The phantom was equipped with markings that allowed accurate setup using planar kV images. Couch walkout during multiple-arc treatments was investigated by tracking a ball pointer, initially positioned at cone beam computed tomography (CBCT) isocenter, as the couch was rotated. Tracks were mapped with no load and a 90 kg stack of plastic plates simulating patient treatment. The dosimetric effect of walkout was assessed computationally by comparing test plans that corrected for walkout to plans that neglected walkout. The plans involved nine 160° arcs of 2.4 × 5 mm2 fields applied at six different couch angles. For end-to-end tests that included CT simulation, target contouring, planning, and delivery, a cylindrical phantom mimicking a 3 mm lesion was constructed and irradiated with the nine-arc regimen. The phantom, lacking markings as setup aids was positioned under CBCT guidance by registering its surface and internal structures with CTs from simulation. Radiochromic film passing through the target center was inserted parallel to the coronal and the sagittal plane for assessment of spatial and dosimetric accuracy. RESULTS: In the single-arc block phantom tests computed maximum doses of all field sizes agreed with measurements within 2.4 ± 2.0%. Profile widths at 50% maximum agreed within 0.2 mm. The largest targeting error was 0.33 mm. The γ-index (3%, 1 mm) averaged over 10 experiments was >1 in only 1% of pixels for field sizes up to 10 × 10 mm2 and rose to 4.4% as field size increased to 20 × 20 mm2 . Table walkout was not affected by load. Walkout shifted the target up to 0.6 mm from CBCT isocenter but, according to computations shifted the dose cloud of the nine-arc plan by only 0.16 mm. Film measurements verified the small dosimetric effect of walkout, allowing walkout to be neglected during planning and treatment. In the end-to-end tests average and maximum targeting errors were 0.30 ± 0.10 and 0.43 mm, respectively. Gamma analysis of coronal and sagittal dose distributions based on a 3%/0.3 mm agreement remained <1 at all pixels. To date, more than 50 functional SRS treatments using MLC-shaped static field arcs have been delivered. CONCLUSION: Stereotactic radiosurgery (SRS) can be planned and delivered on a standard linac without cones or other modifications with better than 0.5 mm spatial and 5% dosimetric accuracy.


Assuntos
Malformações Arteriovenosas/cirurgia , Neoplasias Encefálicas/cirurgia , Aceleradores de Partículas/instrumentação , Imagens de Fantasmas , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Humanos , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos
4.
J Appl Clin Med Phys ; 17(4): 246-253, 2016 07 08.
Artigo em Inglês | MEDLINE | ID: mdl-27455506

RESUMO

Stereotactic radiosurgery (SRS) places great demands on spatial accuracy. Steel BBs used as markers in quality assurance (QA) phantoms are clearly visible in MV and planar kV images, but artifacts compromise cone-beam CT (CBCT) isocenter localization. The purpose of this work was to develop a QA phantom for measuring with sub-mm accuracy isocenter congruence of planar kV, MV, and CBCT imaging systems and to design a practical QA procedure that includes daily Winston-Lutz (WL) tests and does not require computer aid. The salient feature of the phantom (Universal Alignment Ball (UAB)) is a novel marker for precisely localizing isocenters of CBCT, planar kV, and MV beams. It consists of a 25.4mm diameter sphere of polymethylmetacrylate (PMMA) containing a concentric 6.35mm diameter tungsten carbide ball. The large density difference between PMMA and the polystyrene foam in which the PMMA sphere is embedded yields a sharp image of the sphere for accurate CBCT registration. The tungsten carbide ball serves in finding isocenter in planar kV and MV images and in doing WL tests. With the aid of the UAB, CBCT isocenter was located within 0.10 ± 0.05 mm of its true positon, and MV isocenter was pinpointed in planar images to within 0.06 ± 0.04mm. In clinical morning QA tests extending over an 18 months period the UAB consistently yielded measurements with sub-mm accuracy. The average distance between isocenter defined by orthogonal kV images and CBCT measured 0.16 ± 0.12 mm. In WL tests the central ray of anterior beams defined by a 1.5 × 1.5 cm2 MLC field agreed with CBCT isocenter within 0.03 ± 0.14 mm in the lateral direction and within 0.10 ± 0.19 mm in the longitudinal direction. Lateral MV beams approached CBCT isocenter within 0.00 ± 0.11 mm in the vertical direction and within -0.14 ± 0.15 mm longitudinally. It took therapists about 10 min to do the tests. The novel QA phantom allows pinpointing CBCT and MV isocenter positions to better than 0.2 mm, using visual image registration. Under CBCT guidance, MLC-defined beams are deliverable with sub-mm spatial accuracy. The QA procedure is practical for daily tests by therapists.


Assuntos
Tomografia Computadorizada de Feixe Cônico/métodos , Processamento de Imagem Assistida por Computador/métodos , Aceleradores de Partículas/instrumentação , Imagens de Fantasmas , Garantia da Qualidade dos Cuidados de Saúde/métodos , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/normas , Humanos , Posicionamento do Paciente , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada
5.
Adv Radiat Oncol ; 9(4): 101417, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38435965

RESUMO

Purpose: The use of deep learning to auto-contour organs at risk (OARs) in gynecologic radiation treatment is well established. Yet, there is limited data investigating the prospective use of auto-contouring in clinical practice. In this study, we assess the accuracy and efficiency of auto-contouring OARs for computed tomography-based brachytherapy treatment planning of gynecologic malignancies. Methods and Materials: An inhouse contouring tool automatically delineated 5 OARs in gynecologic radiation treatment planning: the bladder, small bowel, sigmoid, rectum, and urethra. Accuracy of each auto-contour was evaluated using a 5-point Likert scale: a score of 5 indicated the contour could be used without edits, while a score of 1 indicated the contour was unusable. During scoring, automated contours were edited and subsequently used for treatment planning. Dice similarity coefficient, mean surface distance, 95% Hausdorff distance, Hausdorff distance, and dosimetric changes between original and edited contours were calculated. Contour approval time and total planning time of a prospective auto-contoured (AC) cohort were compared with times from a retrospective manually contoured (MC) cohort. Results: Thirty AC cases from January 2022 to July 2022 and 31 MC cases from July 2021 to January 2022 were included. The mean (±SD) Likert score for each OAR was the following: bladder 4.77 (±0.58), small bowel 3.96 (±0.91), sigmoid colon 3.92 (±0.81), rectum 4.6 (±0.71), and urethra 4.27 (±0.78). No ACs required major edits. All OARs had a mean Dice similarity coefficient > 0.86, mean surface distance < 0.48 mm, 95% Hausdorff distance < 3.2 mm, and Hausdorff distance < 10.32 mm between original and edited contours. There was no significant difference in dose-volume histogram metrics (D2.0 cc/D0.1 cc) between original and edited contours (P values > .05). The average time to plan approval in the AC cohort was 19% less than the MC cohort. (AC vs MC, 117.0 + 18.0 minutes vs 144.9 ± 64.5 minutes, P = .045). Conclusions: Automated contouring is useful and accurate in clinical practice. Auto-contouring OARs streamlines radiation treatment workflows and decreases time required to design and approve gynecologic brachytherapy plans.

6.
Int J Gynecol Cancer ; 23(3): 559-66, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23385283

RESUMO

OBJECTIVE: The objective of this study was to evaluate the University of Alabama at Birmingham experience with routine intraoperative ultrasound (IUS)-guided tandem placement for cervical cancer. METHODS: Between 1999 and 2008, 243 cervical cancer patients underwent IUS-guided tandem placement. One hundred thirty-nine patients received low-dose-rate brachytherapy, and 104 received high-dose-rate brachytherapy. Three hundred fifty-six IUS-guided procedures were performed. Clinical and imaging data were retrospectively analyzed to evaluate complications requiring reinsertion of tandem placement in the context of IUS. RESULTS: All 243 cervical cancer patients completed intracavitary brachytherapy. Five (1.4%) of 356 IUS-guided applicator placements resulted in uterine perforation. All of these patients underwent successful tandem insertion on the second attempt, and no significant clinical sequelae occurred. Intraoperative ultrasound enabled direct uterine visualization and facilitated real-time feedback for selection of a suitable tandem length and curvature; no suboptimal placements requiring return to the operating room occurred (excluding perforation). CONCLUSIONS: In this large series, IUS guidance substantially increased the rate of successful applicator placement and diminished the rate of uterine perforation relative to historical controls. We strongly recommend the use of IUS guidance during operative intrauterine tandem placement for cervical cancer.


Assuntos
Braquiterapia/instrumentação , Radioterapia Guiada por Imagem , Neoplasias do Colo do Útero/radioterapia , Adulto , Idoso , Idoso de 80 Anos ou mais , Braquiterapia/métodos , Feminino , Seguimentos , Humanos , Cuidados Intraoperatórios , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Prognóstico , Planejamento da Radioterapia Assistida por Computador , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Ultrassonografia , Neoplasias do Colo do Útero/diagnóstico por imagem , Adulto Jovem
7.
J Exp Clin Cancer Res ; 42(1): 61, 2023 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-36906664

RESUMO

We recently identified CD46 as a novel prostate cancer cell surface antigen that shows lineage independent expression in both adenocarcinoma and small cell neuroendocrine subtypes of metastatic castration resistant prostate cancer (mCRPC), discovered an internalizing human monoclonal antibody YS5 that binds to a tumor selective CD46 epitope, and developed a microtubule inhibitor-based antibody drug conjugate that is in a multi-center phase I trial for mCRPC (NCT03575819). Here we report the development of a novel CD46-targeted alpha therapy based on YS5. We conjugated 212Pb, an in vivo generator of alpha-emitting 212Bi and 212Po, to YS5 through the chelator TCMC to create the radioimmunoconjugate, 212Pb-TCMC-YS5. We characterized 212Pb-TCMC-YS5 in vitro and established a safe dose in vivo. We next studied therapeutic efficacy of a single dose of 212Pb-TCMC-YS5 using three prostate cancer small animal models: a subcutaneous mCRPC cell line-derived xenograft (CDX) model (subcu-CDX), an orthotopically grafted mCRPC CDX model (ortho-CDX), and a prostate cancer patient-derived xenograft model (PDX). In all three models, a single dose of 0.74 MBq (20 µCi) 212Pb-TCMC-YS5 was well tolerated and caused potent and sustained inhibition of established tumors, with significant increases of survival in treated animals. A lower dose (0.37 MBq or 10 µCi 212Pb-TCMC-YS5) was also studied on the PDX model, which also showed a significant effect on tumor growth inhibition and prolongation of animal survival. These results demonstrate that 212Pb-TCMC-YS5 has an excellent therapeutic window in preclinical models including PDXs, opening a direct path for clinical translation of this novel CD46-targeted alpha radioimmunotherapy for mCRPC treatment.


Assuntos
Neoplasias de Próstata Resistentes à Castração , Radioimunoterapia , Masculino , Animais , Humanos , Radioimunoterapia/métodos , Chumbo , Partículas alfa , Neoplasias de Próstata Resistentes à Castração/tratamento farmacológico , Radioisótopos de Chumbo/uso terapêutico , Proteína Cofatora de Membrana
8.
Cureus ; 14(4): e23893, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35530902

RESUMO

Purpose For patient comfort and safety, irradiation times should be kept at a minimum while maintaining high treatment quality. In this study of high dose rate (HDR) therapy with a vaginal cylinder, we used the butterfly optimization algorithm (BOA) to simultaneously optimize individual dwell times for precise dose conformity and for the reduction of total dwell time. Material and methods BOA is a population-based, meta-heuristic algorithm that averts local minima by conducting intensive local and global searching based on switching probability. We constructed an objective function (a stimulus intensity function) that consisted of two components. The first one was the root-mean-squared dose error (RMSE) defined as the square root of the sum of squared differences between the prescribed and delivered dose at the constraint points. The second component was weighted total treatment time. Eight previously treated cases were retrospectively reviewed by re-optimizing the clinical treatment plans with BOA.  Results Compared to the eight original plans generated with the commercial adaptive volume optimization algorithm (AVOA), the BOA-optimized plans reduced treatment times by 5.4% to 8.9%, corresponding to a time-saving of 13.1 to 47.7 seconds with the activities on the treatment day and saving from 29.3 to 64.6 seconds if treated with an activity of 5 CI. Dose deviations from the prescription were smaller than in the original plans. Conclusion  Dose optimizations based on the BOA algorithm yield closer dose conformity in vaginal HDR treatment than AVOA. Incorporating total treatment time into the optimization algorithm reduces the delivery time while having only a small effect on dose conformity.

9.
Cureus ; 14(6): e26303, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35911294

RESUMO

Purpose This study aimed to explore the relationship between applicator surface dose and 5 mm-depth dose and to optimize both locations simultaneously for three most used cylinder sizes (2.5, 3.0, and 3.5 cm in diameter) in treating patients with endometrial adenocarcinoma. Materials and methods A total of 216 plans were created for each dose level and applicator size. For each dose level, four plans were created with single or double prescription doses. For plans with double prescription doses, the dose constraints were applied to all those points on the surface and 5 mm depth and optimize the two sites simultaneously.  Results A dose table between surface and 5 mm depth and its fifth order polynomial mapping functions were established for each applicator size, so any prescribed dose at one site can find the prescription dose on the other site in optimization on both locations. For plans with a 5 mm-depth prescription, the maximum dose on the surface can be reduced from 145% to 133% if the surface prescription dose is also used; for plans with surface dose prescription, the minimum dose and mean dose can be improved by 2% if 5 mm-depth dose prescription is also used in optimization. Conclusion Dose table and their mapping functions between surface prescription dose and their corresponding 5 mm-depth doses were created. A new optimization method that uses two prescription doses on both surface and 5 mm-depth sites was proposed to reduce the hot dose on the surface and improve the cold dose at 5 mm depth.

10.
Am J Cancer Res ; 12(9): 4448-4457, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36225630

RESUMO

RRx-001, a CD47 antagonist via its inhibition of MYC and the γ-subtype of the peroxisome proliferator-activated receptor (PPAR) has been associated to date with minimal toxicity. The aim of this post-hoc analysis was to evaluate the toxicity and efficacy of RRx-001 in Asian patients since RRx-001, in the context of multiple Phase 3 studies, will be administered in China and Chinese territories as well as potentially throughout the rest of Asia. Patients received 4 mg of RRx-001 in three different antitumor clinical trials with chemotherapy and/or radiation and a retrospective subset efficacy and toxicity analysis was conducted for patients with Asian ancestry in comparison to patients with other ethnic backgrounds. The toxicity and efficacy data from these studies were similar between Asians and the rest of the treated patients. While the sample sizes are too small to draw definitive conclusions, at a dose of 4 mg, when RRx-001 is combined with chemotherapy, no apparent differences in terms of safety and efficacy are observed in cancer patients with Asian ancestry.

11.
Med Dosim ; 46(4): 431-434, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34344548

RESUMO

The purpose of study is to measure Point A pear-shaped isodose dimensions of the conventional intracavitary brachytherapy with various sizes of colpostats and analyze which size of tumor is the optimal for 3-D interstitial brachytherapy. CT simulation was performed with Fletcher type applicator using various sizes of colpostats (2.0, 2.5, and 3.0 cm diameter). The Manchester standard loading (dwell time) system was used to generate pear-shaped isodose envelopes with high-dose rate iridium-192 according to the colpostat sizes. The size of the pear-shaped envelope was measured at 5 different levels: A-level (center of the colpostats), B-level (top of the colpostats), C-level (between B and D), D-level (Point A), and E-level (1.0 cm above Point A). In this study, it was assumed that uterine tandem was located at the center of tumor. For width of pear-shape: At the A-level, 6.4, 7.3, and 8.0 cm for 2.0, 2.5, and 3.0 cm colpostats, respectively. At the B-level, 5.8, 6.4, and 6.8 cm for 2, 2.5, and 3.0 cm colpostats, respectively. At the C-level, 4.6, 4.8, and 4.8 for 2.0, 2.5, and 3.0 cm colpostats, respectively. At the D-level, 4.0 cm for all different size. At the E-level, 3.8 cm for all 3 different size colpostats. A-level was the largest dimension of pear-shape. However, it was located in the upper vagina below the main cervical mass. The center of the effective pear-shape size for tumor was between the C and D levels. For thickness, all 5 different levels were ranging 3.7 to 4.0 cm. For height, the length of height was dependent on the tandem length. Therefore, the pear-shape envelope was able to accommodate up to 4.0 cm diameter volume. According to our analysis of conventional pear-shape dimension, 3-D interstitial brachytherapy should be considered for tumors larger than 4.0 cm for symmetrical tumor.


Assuntos
Braquiterapia , Neoplasias do Colo do Útero , Simulação por Computador , Feminino , Humanos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Neoplasias do Colo do Útero/radioterapia , Vagina
12.
Hua Xi Kou Qiang Yi Xue Za Zhi ; 39(2): 215-220, 2021 Apr 01.
Artigo em Zh | MEDLINE | ID: mdl-33834678

RESUMO

Photodynamic therapy (PDT) has developed rapidly in basic and clinical research, and its therapeutic prospects have received increasing attention. PDT has the advantages of minimally invasive, low toxicity, high selectivity, good reproducibility, protection of appearance and vital organ function, and has become a treatment. With the development of medicine, the field of application of PDT becomes more wildly, and brings a new direction for the treatment of oral diseases. This article reviews the basic principles, treatment elements and research results of PDT in the treatment of oral diseases.


Assuntos
Doenças da Boca , Fotoquimioterapia , Humanos , Doenças da Boca/tratamento farmacológico , Fármacos Fotossensibilizantes/uso terapêutico , Reprodutibilidade dos Testes
13.
Hua Xi Kou Qiang Yi Xue Za Zhi ; 39(1): 99-104, 2021 Feb 01.
Artigo em Inglês, Zh | MEDLINE | ID: mdl-33723944

RESUMO

Oral squamous cell carcinoma (OSCC) is the most frequent tumour in head and neck malignant. The current treatment is mainly based on surgery therapy, radiation therapy and chemical therapy. Meanwhile, there are many a defect in the treatment. For example, there are many defects in radiotherapy. Radioactive salivatitis is the most common. In addition, there are a series of changes such as dry mouth, oral mucositis, rampant dental caries, and radioactive osteomyelitis of jaw, which cause swallowing, chewing problems, and taste dysfunction. Currently, the research on radioactive salivatitis is progressing rapidly, but its mechanism is more complication. This paper review aims to summarize the research progress in this field.


Assuntos
Carcinoma de Células Escamosas , Cárie Dentária , Neoplasias de Cabeça e Pescoço , Neoplasias Bucais , Lesões por Radiação , Xerostomia , Neoplasias de Cabeça e Pescoço/radioterapia , Humanos , Glândulas Salivares , Xerostomia/etiologia
14.
Clin Cancer Res ; 27(5): 1305-1315, 2021 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-33293372

RESUMO

PURPOSE: We recently identified CD46 as a novel therapeutic target in prostate cancer. In this study, we developed a CD46-targeted PET radiopharmaceutical, [89Zr]DFO-YS5, and evaluated its performance for immunoPET imaging in murine prostate cancer models. EXPERIMENTAL DESIGN: [89Zr]DFO-YS5 was prepared and its in vitro binding affinity for CD46 was measured. ImmunoPET imaging was conducted in male athymic nu/nu mice bearing DU145 [AR-, CD46+, prostate-specific membrane antigen-negative (PSMA-)] or 22Rv1 (AR+, CD46+, PSMA+) tumors, and in NOD/SCID gamma mice bearing patient-derived adenocarcinoma xenograft, LTL-331, and neuroendocrine prostate cancers, LTL-331R and LTL-545. RESULTS: [89Zr]DFO-YS5 binds specifically to the CD46-positive human prostate cancer DU145 and 22Rv1 xenografts. In biodistribution studies, the tumor uptake of [89Zr]DFO-YS5 was 13.3 ± 3.9 and 11.2 ± 2.5 %ID/g, respectively, in DU145 and 22Rv1 xenografts, 4 days postinjection. Notably, [89Zr]DFO-YS5 demonstrated specific uptake in the PSMA- and AR-negative DU145 model. [89Zr]DFO-YS5 also showed uptake in the patient-derived LTL-331 and -331R models, with particularly high uptake in the LTL-545 neuroendocrine prostate cancer tumors (18.8 ± 5.3, 12.5 ± 1.8, and 32 ± 5.3 %ID/g in LTL-331, LTL-331R, and LTL-545, respectively, at 4 days postinjection). CONCLUSIONS: [89Zr]DFO-YS5 is an excellent PET imaging agent across a panel of prostate cancer models, including in both adenocarcinoma and neuroendocrine prostate cancer, both cell line- and patient-derived xenografts, and both PSMA-positive and -negative tumors. It demonstrates potential for clinical translation as an imaging agent, theranostic platform, and companion biomarker in prostate cancer.


Assuntos
Adenocarcinoma/patologia , Imunoconjugados/química , Proteína Cofatora de Membrana/imunologia , Imagem Molecular/métodos , Tumores Neuroendócrinos/patologia , Neoplasias da Próstata/patologia , Compostos Radiofarmacêuticos/farmacocinética , Adenocarcinoma/diagnóstico por imagem , Adenocarcinoma/imunologia , Adenocarcinoma/metabolismo , Animais , Apoptose , Proliferação de Células , Humanos , Masculino , Camundongos , Camundongos Endogâmicos NOD , Camundongos Nus , Camundongos SCID , Tumores Neuroendócrinos/diagnóstico por imagem , Tumores Neuroendócrinos/imunologia , Tumores Neuroendócrinos/metabolismo , Tomografia por Emissão de Pósitrons/métodos , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/imunologia , Neoplasias da Próstata/metabolismo , Distribuição Tecidual , Células Tumorais Cultivadas , Ensaios Antitumorais Modelo de Xenoenxerto , Zircônio/química
15.
Life Sci ; 265: 118748, 2021 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-33189827

RESUMO

AIMS: Radiotherapy has become a basic treatment modality for head and neck cancer. However, radiotherapy results in inevitable side effects, particularly radiation sialadenitis, that significantly impairs quality of life. A previous study indicated that nerve growth factor (NGF) has a radio-protective effect, but the mechanism was not determined in salivary glands. In this study, we explored the functional role and mechanism regarding how NGF protects salivary glands against IR-induced damage. MAIN METHODS: Human salivary gland (HSG) cells and C57BL/6 mice were selected to establish an IR-induced salivary gland damage model in vitro and in vivo. Recombinant NGF protein and NGF siRNA and over-expression plasmids were applied to manipulate NGF expression in vitro. AAV-NGF was retrogradely perfused into the submandibular gland (SMG) through the SMG duct to manipulate NGF expression in vitro. Small-molecule inhibitors and siRNAs were applied to inhibit AKT and JNK. Western blotting, quantitative PCR, flow cytometry and histology assays were performed to analyse the functional role and mechanism of NGF. KEY FINDINGS: Our study demonstrated that NGF expression was upregulated following radiotherapy both in human HSG cells and mouse SMG tissues. NGF could reduce IR-induced HSG cell apoptosis, and AAV-mediated gene therapy could restore the salivary flow rate and protect the salivary gland against IR-induced apoptosis in vivo. Mechanistically, NGF protects salivary glands from IR-induced apoptosis by de-phosphorylating JNK kinase rather than promoting AKT phosphorylation. SIGNIFICANCE: The current study findings indicated that the modulation of the NGF pathway might prevent IR-induced salivary hypo-function.


Assuntos
Fator de Crescimento Neural/metabolismo , Fator de Crescimento Neural/farmacologia , Glândulas Salivares/efeitos dos fármacos , Animais , Apoptose/efeitos dos fármacos , Técnicas de Cultura de Células , China , Feminino , Neoplasias de Cabeça e Pescoço/patologia , Humanos , MAP Quinase Quinase 4/metabolismo , Camundongos , Camundongos Endogâmicos C57BL , Substâncias Protetoras/farmacologia , Qualidade de Vida , Lesões Experimentais por Radiação/prevenção & controle , Radioterapia/efeitos adversos , Glândulas Salivares/metabolismo , Glândulas Salivares/patologia , Glândula Submandibular/efeitos dos fármacos , Glândula Submandibular/metabolismo , Glândula Submandibular/patologia
16.
Cureus ; 12(6): e8618, 2020 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-32676253

RESUMO

Purpose Our study reports the clinical outcomes of patients treated with 5-mm isotropic margin, fiducial-guided stereotactic body radiation therapy (SBRT) for early stage non-small cell lung cancer (NSCLC). We also sought to assess the effect of histological subtype on local control. Methods We retrospectively reviewed the charts of all patients treated with SBRT for NSCLC between 2007 and 2017 at our institution. All patients who had implanted fiducial markers, planning target volume (PTV) margins of 5 mm or less, early stage disease (T1-T2, N0), and at least one follow-up CT were included in this analysis. Estimates of local control were generated using the Kaplan-Meier method, and differences between survival curves were assessed using the log-rank test. Results A total of 152 patients met the inclusion criteria for this analysis, with a median follow-up of 27.9 months. Patients received 54 Gy in three fractions for peripheral tumors and 48-52.5 Gy in four to five fractions for central tumors. NSCLC histology was adenocarcinoma in 69 (45.4%) cases, squamous cell carcinoma in 65 (42.8%) cases, and other or non-subtyped in 18 (11.8%) cases. Across the entire cohort, the two-year estimate of local control was 95.1%. When histology was considered, the two-year estimate of local control among patients with adenocarcinoma was 95.6% as compared with 85.0% for patients with other subtypes (p=0.044). Conclusions Fiducial-guided, isotropic 5-mm PTV margin for thoracic SBRT did not compromise local control compared with historical standards. In this series, patients with adenocarcinoma experienced improved local control compared with squamous cell carcinoma.

17.
J Nucl Med ; 50(4): 644-52, 2009 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19289440

RESUMO

UNLABELLED: Absorbed-dose calculations provide a scientific basis for evaluating the biologic effects associated with administered radiopharmaceuticals. In cancer therapy, radiation dosimetry supports treatment planning, dose-response analyses, predictions of therapy effectiveness, and completeness of patient medical records. In this study, we evaluated the organ radiation absorbed doses from intravenously administered (111)In- and (90)Y-ibritumomab tiuxetan. METHODS: Ten patients (6 men and 4 women) with non-Hodgkin lymphoma, cared for at 3 different medical centers, were administered the tracer (111)In-ibritumomab tiuxetan and assessed using planar scintillation camera imaging at 5 time points and CT-organ volumetrics to determine patient-specific organ biokinetics and dosimetry. Explicit attenuation correction based on the transmission scan or transmission measurements provided the fraction of (111)In-administered activity in 7 major organs, the whole body, and remainder tissues over time through complete decay. Time-activity curves were constructed, and radiation doses were calculated using MIRD methods and implementing software. RESULTS: Mean radiation absorbed doses for (111)In- and for (90)Y-ibritumomab tiuxetan administered to 10 cancer patients are reported for 24 organs and the whole body. Biologic uptake and retention data are given for 7 major source organs, remainder tissues, and the whole body. Median absorbed dose values calculated by this method were compared with previously published dosimetry for ibritumomab tiuxetan and the product package insert. CONCLUSION: In high-dose radioimmunotherapy, the importance of patient-specific dosimetry becomes obvious when the objective of treatment planning is to achieve disease cures, safely, by limiting radiation dose to any critical normal organ to its maximum tolerable value. Compared with the current package insert, we found differences in median absorbed dose by multiples of 24 in the kidneys, 1.8 in the red marrow, 0.65 in the liver, 0.077 in the intestinal wall, 0.30 in the lungs, 0.46 in the spleen, and 0.34 in the heart wall.


Assuntos
Anticorpos Monoclonais/análise , Anticorpos Monoclonais/farmacocinética , Carga Corporal (Radioterapia) , Radioisótopos de Índio/análise , Radioisótopos de Índio/farmacocinética , Linfoma não Hodgkin/metabolismo , Contagem Corporal Total , Humanos , Taxa de Depuração Metabólica , Especificidade de Órgãos , Doses de Radiação , Distribuição Tecidual
18.
Technol Cancer Res Treat ; 8(4): 307-14, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19645523

RESUMO

We compare measured output factors of clinical electron fields to those calculated by a commercial treatment planning system based on an electron Monte Carlo algorithm. The measured data is comprised of 195 fields with energies 6 to 18 MeV, applicator sizes 6 x 6 cm(2) to 25 x 25 cm(2), and source to surface distances (SSDs) of 97 to 107 cm. Due to a scarcity of clinical fields for the highest energies and the largest applicator sizes, additional measurements were made at arbitrarily chosen large field sizes at previously not used energies, for a total of 223 output factors. The difference between calculation and measurement ranged from -2.9% to 3.9%, with a mean difference of -0.2%. Half of the field shapes had a difference with magnitude less than 0.8%. Only 7 (3%) of the field shapes were outliers, having differences greater than 2%. All outliers had field widths at the normalization point < 3.5 cm, were applied at SSDs > 100 cm, were inserts for the 25 _ 25 cm(2) applicator, or had more than one of these characteristics. For narrow and elongated fields the TPS slightly overestimated output factors, whereas for field shapes with aspect ratio close to 1 the TPS slightly underestimated the output factors. No strong dependence of the difference on energy was observed.


Assuntos
Elétrons/uso terapêutico , Método de Monte Carlo , Planejamento da Radioterapia Assistida por Computador/métodos , Algoritmos , Humanos , Dosagem Radioterapêutica
19.
J Appl Clin Med Phys ; 10(1): 90-102, 2009 Feb 03.
Artigo em Inglês | MEDLINE | ID: mdl-19223839

RESUMO

There is a considerable underdosage (11%-13%) of PTV due to anisotropy of a stationary source in breast balloon brachytherapy. We improved the PTV coverage by varying multiple dwell positions and weights. We assumed that the diameter of spherical balloons varied from 4.0 cm to 5.0 cm, that the PTV was a 1-cm thick spherical shell over the balloon (reduced by the small portion occupied by the catheter path), and that the number of dwell positions varied from 2 to 13 with 0.25-cm steps, oriented symmetrically with respect to the balloon center. By assuming that the perfect PTV coverage can be achieved by spherical dose distributions from an isotropic source, we developed an optimization program to minimize two objective functions defined as: (1) the number of PTV-voxels having more than 10% difference between optimized doses and spherical doses, and (2) the difference between optimized doses and spherical doses per PTV-voxel. The optimal PTV coverage occurred when applying 8-11 dwell positions with weights determined by the optimization scheme. Since the optimization yields ellipsoidal isodose distributions along the catheter, there is relative skin sparing for cases with source movement approximately tangent to the skin. We also verified the optimization in CT-based treatment planning systems. Our volumetric dose optimization for PTV coverage showed close agreement to linear or multiple-points optimization results from the literature. The optimization scheme provides a simple and practical solution applicable to the clinic.


Assuntos
Braquiterapia/instrumentação , Neoplasias da Mama/radioterapia , Radioisótopos de Irídio/administração & dosagem , Braquiterapia/métodos , Cateterismo , Feminino , Humanos , Radioisótopos de Irídio/uso terapêutico , Dosagem Radioterapêutica
20.
Phys Med ; 66: 1-7, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31563726

RESUMO

PURPOSE: To investigate the dosimetry of 125I seed-loaded stent system currently used for an adjuvant treatment of portal vein tumor thrombosis (PVTT). METHODS: The stent system consisted of an inner metallic stent and outer seed-loaded capsules. Four arrays of 125I seeds were attached longitudinally to the outer surface of the stent at 90° separation. 145 Gy was prescribed at 5 mm from the axes of seed-arrays. For the geometries of the 4-array, and potential 6- and 8-array configurations, treatment planning system (TPS) and Monte Carlo (MC) calculations were performed to evaluate 3D dose distributions and dosimetric impact of the metallic stent. RESULTS: The MC simulations indicated the metallic stent reduced a dose to the prescription points by over 10%, compared to the water-based TPS results. The total activity calculated by the water-based TPS to deliver the prescription dose should compensate for this amount of reduction. The MC- and TPS-calculated doses normalized to the prescription points for the current configuration were in agreements within 4.3% on a cylindrical surface along 5 mm from the axes of seed-arrays. The longitudinal underdosage worsened as approaching the edge of arrays, and ranged from 2.8% to 25.5%. The angular underdosage between neighboring arrays was 2.1%-8.9%. CONCLUSIONS: With this compensation and a special care of near-edge underdosage, the current 4-array system can provide adequate dose coverage for treatment of PVTT. Further dosimetric homogeneity can be achieved using 6-or 8-array configurations.


Assuntos
Radioisótopos do Iodo/uso terapêutico , Veia Porta/efeitos da radiação , Doses de Radiação , Stents , Trombose/radioterapia , Método de Monte Carlo , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa