1.
J Cardiovasc Electrophysiol ; 34(4): 888-897, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36852902

RESUMO

BACKGROUND/OBJECTIVES: The QDOT-MICRO™ catheter allows very high-power and short-duration (vHPSD) ablation. This study aimed to investigate lesion characteristics using different ablation settings. METHODS: Radiofrequency applications (90 W/4 s, temperature-control mode with 55°C or 60°C target) were performed in excised porcine myocardium using three different approaches: single (SA), double nonrepetitive (DNRA), and double repetitive applications (DRA). Applications were performed with an interval of 1 min for DNRA, and without interval for DRA. RESULTS: A total of 480 lesions were analyzed. Lesion depth and volume were largest for DRA followed by DNRA and SA regardless of catheter direction (depth: 3.8 vs. 3.3 vs. 2.6 mm, p < .001 for all comparisons; volume: 176.6 vs. 145.1 vs. 97.0 mm3 , p < .001 for all comparisons). Surface area was significantly larger for DRA than for SA (45.1 vs. 38.3 mm2 , p < .001) and larger for DNRA than for SA (44.5 vs. 38.3 mm2 , p < .001), but was similar between DRA and DNRA (45.1 vs. 44.5 mm2 , p = .54). Steam-pops more frequently occurred for DRA than for SA (15.6% vs. 4.4%, p = .004) and DNRA (15.6% vs. 6.9%, p = .061), but the incidence was similar between SA and DNRA (4.4% vs. 6.9%, p = 1). Although surface area and lesion volume were larger in lesions with steam-pops than without steam-pops (46.5 vs. 38.1 mm2 , p = .018 and 128.3 vs. 96.8 mm3 , p = .068, respectively), lesions were not deeper (pop(+): 2.5 mm vs. pop(-): 2.6 mm, p = .75). CONCLUSIONS: DNRA produces larger lesions than SA without increasing the risk of steam-pops. DRA produces the largest lesions among the three groups, but with an increased risk of steam-pops. Even with steam-pops, lesions do not become deeper in vHPSD ablation.


Assuntos
Ablação por Cateter , Vapor , Suínos , Animais , Ablação por Cateter/efeitos adversos , Irrigação Terapêutica/efeitos adversos , Desenho de Equipamento , Catéteres
2.
J Cardiovasc Electrophysiol ; 34(12): 2484-2492, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37752712

RESUMO

INTRODUCTION: Cryoballoon ablation (CBA) of the left atrial (LA) roof in addition to a pulmonary vein isolation has been expected to improve the clinical outcomes post-atrial fibrillation (AF) ablation. We demonstrated the characteristics and efficacy of CBA of the LA roof through our experience with a large volume of procedures. METHODS: Among 1036 AF ablation procedures with CBA of the LA roof, 834 patients who underwent a de novo ablation were analyzed. RESULTS: Complete LA roof line conduction block was obtained in 767 patients (92.0%) solely by CBA (Group A). Compared with the other patients (Group B), the mean nadir balloon temperature during CBA of the LA roof (-44.5 ± 5.6°C for Group A vs. -40.5 ± 7.5°C for Group B, p < .01) and number of cryoballoon applications during the LA roof ablation with a circular mapping catheter located in the left superior pulmonary vein (1.3 ± 0.8 for Group A vs. 1.6 ± 1.0 for Group B, p = .02) were significantly lower in Group A. A multivariate analysis revealed that those were predictors of a complete LA roof conduction block after only CBA. The 1-year Kaplan-Meier atrial arrhythmia free rate estimates were 80.6% for Group A and 59.0% for Group B (p < .01). CONCLUSION: Complete LA roof line conduction block could be obtained with a cryoballoon without touch-up ablation in most cases. The LA roof CBA with a circular mapping catheter located in the right superior pulmonary vein was preferable to obtaining complete LA roof conduction block, which was important with regard to the clinical outcomes.


Assuntos
Fibrilação Atrial , Bloqueio Atrioventricular , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Resultado do Tratamento , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Átrios do Coração/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Recidiva
3.
J Cardiovasc Electrophysiol ; 34(4): 908-917, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36906814

RESUMO

INTRODUCTION: The QDOT-MicroTM catheter is a novel irrigated contact force (CF) sensing catheter which benefits from thermocouples for temperature monitoring, allowing temperature-flow-controlled (TFC) ablation. We compared lesion metrics at fixed ablation index (AI) value during TFC-ablation and conventional power-controlled (PC)-ablation. METHODS: A total of 480 RF-applications were performed on ex-vivo swine myocardium with predefined AI targets (400/550) or until steam-pop occurred, using the QDOT-MicroTM (TFC-ablation) and Thermocool SmartTouch SFTM (PC-ablation). RESULTS: Both TFC-ablation and PC-ablation produced similar lesions in volume (218 ± 116 vs. 212 ± 107 mm3 , p = .65); however, lesions using TFC-ablation were larger in surface area (41.3 ± 8.8 vs. 34.8 ± 8.0 mm2 , p < .001) and shallower in depth (4.0 ± 1.0 vs. 4.2 ± 1.1 mm, p = .044). Average power tended to be lower in TFC-alation (34.2 ± 8.6 vs. 36.9 ± 9.2, p = .005) compared to PC-ablation due to automatic regulation of temperature and irrigation-flow. Although steam-pops were less frequent in TFC-ablation (24% vs. 15%, p = .021), they were particularly observed in low-CF (10 g) and high-power ablation (50 W) in both PC-ablation (n = 24/240, 10.0%) and TFC-ablation (n = 23/240, 9.6%). Multivariate analysis revealed that high-power, low-CF, long application time, perpendicular catheter orientation, and PC-ablation were risk factors for steam-pops. Furthermore, activation of automatic regulation of temperature and irrigation-flow was independently associated with high-CF and long application time while ablation power had no significant relationship. CONCLUSIONS: With a fixed target AI, TFC-ablation reduced the risk of steam-pops, producing similar lesions in volume, but with different metrics in this ex-vivo study. However, lower CF and higher power in fixed-AI ablation may increase the risk of steam-pops.


Assuntos
Ablação por Cateter , Vapor , Suínos , Animais , Temperatura , Ablação por Cateter/efeitos adversos , Irrigação Terapêutica/efeitos adversos , Desenho de Equipamento
4.
J Cardiovasc Electrophysiol ; 34(8): 1671-1680, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37337433

RESUMO

INTRODUCTION: Little is known about the impact of blood-pool local impedance (LI) on lesion characteristics and the incidence of steam pops. METHODS: Radiofrequency applications at a range of powers (30, 40, and 50 W), contact forces (CF) (5, 15, and 25 g), and durations (15, 30, 45, and 120 s) using perpendicular/parallel catheter orientation were performed in 40 excised porcine preparations, using a catheter capable of monitoring LI (StablePoint©, Boston Scientific). To simulate the variability in blood-pool impedance, the saline-pool LI was modulated by calibrating saline concentrations. Lesion characteristics were compared under three values of saline-pool LI: 120, 160, and 200 Ω. RESULTS: Of 648 lesions created, steam pops occurred in 175 (27.0%). When power, CF, time, and catheter orientation were adjusted, ablation at a saline-pool impedance of 160 or 200 Ω more than doubled the risk of steam pops compared with a saline-pool impedance of 120 Ω (Odds ratio = 2.31; p = .0002). Lesions in a saline-pool impedance of 120 Ω were significantly larger in surface area (50 [38-62], 45 [34-56], and 41 [34-60] mm2 for 120, 160, and 200 Ω, p < .05), but shallower in depth (4.0 [3-5], 4.4 [3.2-5.3], and 4.5 [3.8-5.5] mmfor 120, 160, and 200 Ω, respectively, p < .05) compared with the other two settings. The correlation between the absolute LI-drop and lesion size weakened as the saline-pool LI became higher (e.g., 120 Ω group (r2 = .30, r2 = .18, and r2 = .16, respectively for 120, 160, and 200 Ω), but the usage of %LI-drop (= absolute LI-drop/initial LI) instead of absolute LI-drop may minimize this effect. CONCLUSIONS: In an experimental model, baseline saline-pool impedance significantly affects the lesion metrics and the risk of steam pops.


Assuntos
Ablação por Cateter , Vapor , Suínos , Animais , Impedância Elétrica , Benchmarking , Ablação por Cateter/efeitos adversos , Solução Salina
5.
Europace ; 26(1)2023 12 28.
Artigo em Inglês | MEDLINE | ID: mdl-38096246

RESUMO

AIMS: The usefulness of coronary venous system mapping has been reported for assessing intramural and epicardial substrates in patients with scar-related ventricular tachycardia (VT). However, there has been little data on mapping from coronary arteries. We investigated the safety and utility of mapping from coronary arteries with a novel over-the-wire multielectrode catheter in scar-related VT patients. METHODS AND RESULTS: Ten consecutive scar-related VT patients with non-ischaemic cardiomyopathy who underwent mapping from a coronary artery were analysed. Six patients underwent simultaneous coronary venous mapping. High-density maps were created by combining the left ventricular endocardium and coronary vessels. Substrate maps were created during the baseline rhythm with 2438 points (IQR 2136-3490 points), including 329 (IQR 59-508 points) in coronary arteries. Abnormal bipolar electrograms were successfully recorded within coronary arteries close to the endocardial substrate in seven patients. During VT, isthmus components were recorded within the coronary vessels in three patients with no discernible isthmus components on endocardial mapping. The ablation terminated the VT from an endocardial site opposite the earliest site in the coronary arteries in five patients. CONCLUSION: The transcoronary mapping with an over-the-wire multielectrode catheter can safely record abnormal bipolar electrograms within coronary arteries. Additional mapping data from the coronary vessels have the potential to assess three-dimensional ventricular substrates and circuit structures in scar-related VT patients.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Humanos , Cicatriz/complicações , Cicatriz/diagnóstico por imagem , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/cirurgia , Arritmias Cardíacas , Ventrículos do Coração , Endocárdio , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos
6.
Europace ; 25(9)2023 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-37428890

RESUMO

AIMS: Although the mechanism of an atrial tachycardia (AT) can usually be elucidated using modern high-resolution mapping systems, it would be helpful if the AT mechanism and circuit could be predicted before initiating mapping. OBJECTIVE: We examined if the information gathered from the cycle length (CL) of the tachycardia can help predict the AT-mechanism and its localization. METHODS: One hundred and thirty-eight activation maps of ATs including eight focal-ATs, 94 macroreentrant-ATs, and 36 localized-ATs in 95 patients were retrospectively reviewed. Maximal CL (MCL) and minimal CL (mCL) over a minute period were measured via a decapolar catheter in the coronary sinus. CL-variation and beat-by-beat CL-alternation were examined. Additionally, the CL-respiration correlation was analysed by the RhythmiaTM system. : Both MCL and mCL were significantly shorter in macroreentrant-ATs [MCL = 288 (253-348) ms, P = 0.0001; mCL = 283 (243-341) ms, P = 0.0012], and also shorter in localized-ATs [MCL = 314 (261-349) ms, P = 0.0016; mCL = 295 (248-340) ms, P = 0.0047] compared to focal-ATs [MCL = 506 (421-555) ms, mCL = 427 (347-508) ms]. An absolute CL-variation (MCL-mCL) < 24 ms significantly differentiated re-entrant ATs from focal-ATs with a sensitivity = 96.9%, specificity = 100%, positive predictive value (PPV) = 100%, and negative predictive value (NPV) = 66.7%. The beat-by-beat CL-alternation was observed in 10/138 (7.2%), all of which showed the re-entrant mechanism, meaning that beat-by-beat CL-alternation was the strong sign of re-entrant mechanism (PPV = 100%). Although the CL-respiration correlation was observed in 28/138 (20.3%) of ATs, this was predominantly in right-atrium (RA)-ATs (24/41, 85.7%), rather than left atrium (LA)-ATs (4/97, 4.1%). A positive CL-respiration correlation highly predicted RA-ATs (PPV = 85.7%), and negative CL-respiration correlation probably suggested LA-ATs (NPV = 84.5%). CONCLUSION: Detailed analysis of the tachycardia CL helps predict the AT-mechanism and the active AT chamber before an initial mapping.


Assuntos
Ablação por Cateter , Taquicardia Supraventricular , Humanos , Estudos Retrospectivos , Técnicas Eletrofisiológicas Cardíacas , Taquicardia , Átrios do Coração , Resultado do Tratamento
7.
Circ J ; 87(12): 1757-1764, 2023 11 24.
Artigo em Inglês | MEDLINE | ID: mdl-37899173

RESUMO

BACKGROUND: For lesion size prediction, each input parameter, including ablation energy (AE), and output parameter, such as impedance, is individually used. We hypothesize that using both parameters simultaneously may be more optimal.Methods and Results: Radiofrequency applications at a range of power (30-50 W), contact force (10 g and 20 g), duration (10-60 s), and catheter orientation with normal saline (NS)- or half-normal saline (HNS)-irrigation were performed in excised porcine hearts. The correlations, with lesion size of AE, absolute impedance drop (∆Imp-drop), relative impedance drop (%Imp-drop), and AE*%Imp-drop were examined. Lesion size was analyzed in 283 of 288 lesions (NS-irrigation, n=142; HNS-irrigation, n=141) without steam pops. AE*%Imp-drop consistently showed the strongest correlations with lesion maximum depth (NS-irrigation, ρ=0.91; HNS-irrigation, ρ=0.94), surface area (NS-irrigation, ρ=0.87; HNS-irrigation, ρ=0.86), and volume (NS-irrigation, ρ=0.94; HNS-irrigation, ρ=0.94) compared with the other parameters. Moreover, compared with AE alone, AE*%Imp-drop significantly improved the strength of correlation with lesion maximum depth (AE vs. AE*%Imp-drop, ρ=0.83 vs. 0.91, P<0.01), surface area (ρ=0.73 vs. 0.87, P<0.01), and volume (ρ=0.84 vs. 0.94, P<0.01) with NS-irrigation. This tendency was also observed with HNS-irrigation. Parallel catheter orientation showed a better correlation with lesion depth and volume using ∆Imp-drop, %Imp-drop, and AE*%Imp-drop than perpendicular orientation. CONCLUSIONS: The combination of input and output parameters is more optimal than each single parameter for lesion prediction.


Assuntos
Ablação por Cateter , Solução Salina , Animais , Suínos , Ventrículos do Coração/patologia , Coração , Catéteres , Ablação por Cateter/métodos , Desenho de Equipamento , Impedância Elétrica
8.
Pacing Clin Electrophysiol ; 46(12): 1536-1545, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37957924

RESUMO

BACKGROUND AND AIMS: The safety evaluation of TactiFlex, a novel contact-force sensing catheter with a flexible 4-mm tip irrigated through laser-cut kerfs, has been ongoing. This study aimed to verify the safety of this type of catheter. METHODS: Study 1: Radiofrequency (RF) applications at a range of powers (30-50 W), contact forces (10-20 g), and durations (10-60 s) using perpendicular/parallel catheter orientation with half-normal (HNS) or normal saline irrigation were compared between TactiFlex (4-mm tip) and TactiCath (3.5-mm tip) with temperature-controlled mode in excised porcine hearts. Study 2: The relation between RF applications using TactiFlex and the incidence of steam-pops in the real clinical cases were examined. RESULTS: Study-1: 576 RF lesions were examined. TactiFlex demonstrated a significantly lower risk of steam-pops (5[1.7%] vs. 59[20.5%], p < .0001). Compared to 3.5-mm-tip catheter (TactiCath), 4-mm-tip catheter (TactiFlex) produced smaller lesion volume at perpendicular (193[98-554]mm3 vs. 263[139-436]mm3 , p < .0001), but relatively similar lesion volume at parallel contact (243[105-443]mm3 vs. 278[180-440]mm3 , p = .06). HNS-irrigation tended to increase the lesion volume in both catheters and to increase the incidence of steam-pops with TactiCath, but not with TactiFlex. The cut-off value of %impedance-drop ( = absolute impedance-drop/initial impedance) of 20% predicted steam-pops with a sensitivity = 100% and specificity = 89.6% in TactiFlex. Study-2: 5496 RF applications in 84 patients (51AFs/8ATs/3AVNRTs/4AVRTs/17PVCs/4VTs) using TactiFlex were analyzed. Four steam-pops (0.07%) in three patients with pericardial effusion were observed (%impedance-drop = 24%/26%/29%/35%, respectively). The cut-off value of %impedance-drop = 20%, derived from ex-vivo study, showed sensitivity = 100% and specificity = 90.1% in detecting steam-pops. CONCLUSION: TactiFlex reduced the risk of steam-pops than TactiCath. %impedance-drop ≤ 20% may be reasonable for safely use with a sufficient safety margin. For 4-mm-tip catheter, parallel-contact may be recommended for larger lesion creation.


Assuntos
Ablação por Cateter , Vapor , Humanos , Animais , Suínos , Irrigação Terapêutica , Desenho de Equipamento , Catéteres
9.
Pacing Clin Electrophysiol ; 45(1): 5-13, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34679229

RESUMO

INTRODUCTION: Gastric hypomotility (GH) is a major complication of atrial fibrillation (AF) ablation. We aimed to clarify whether additional cryoballoon ablation (CBA) of the left atrial (LA) roof is associated with GH. METHODS AND RESULTS: This study included 54 patients with non-paroxysmal AF who underwent CBA for pulmonary vein isolation and of the LA roof line. GH was defined according to the results of esophagogastroscopy performed 2 days after ablation. GH was observed in 10 patients. There were significant differences in LA diameter (LAD), right inferior pulmonary vein (RIPV) diameter, and the height of the LA roof from the point where the LA posterior wall and esophagus make contact between patients with (GH+) and without GH (GH-) (LAD: 41.0 [36.3-41.8] mm vs. 46.5 [42.8-50.0] mm, p < .01; RIPV diameter: 19.7 [19.0-20.5] mm vs. 23.2 [21.2-24.9] mm, p < .01; height of LA roof: 5.7 [5.1-6.1] mm vs. 8.8 [7.1-11.2] mm for, p < .01, respectively). Multivariate analysis revealed that LA roof height was a predictor of GH. Moreover, Patient Assessment of Upper Gastrointestinal Disorders-Symptom Severity Index (PAGI-SYM) scores increased significantly 1 week after ablation (from 1.0 [0.0-2.8] to 5.0 [3.0-11.0], p = .03) in patients with GH. CONCLUSION: The height of the LA roof may be a predictor of GH after CBA of the LA roof line. Additionally, GH-related symptoms may still appear 1 week after ablation.


Assuntos
Fibrilação Atrial/cirurgia , Criocirurgia/métodos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/fisiopatologia , Veias Pulmonares/cirurgia , Estômago/fisiopatologia , Idoso , Fibrilação Atrial/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prevalência , Estudos Prospectivos
10.
Int Heart J ; 63(6): 1085-1091, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36450547

RESUMO

Pulmonary vein isolation (PVI) with a balloon-based visually guided laser ablation (VGLA) is regarded as a useful therapeutic tool for treating atrial fibrillation (AF). The clinical efficacy of a VGLA has never been fully investigated in patients with left common pulmonary vein (LCPV). We investigated the procedural safety as well as clinical usefulness of VGLA in patients with LCPV.This study consisted of 130 consecutive patients who underwent VGLA of de novo nonvalvular paroxysmal AF.Eleven patients (8.5%) had an LCPV (ostium maximal average diameter: 27.5 ± 4.9 mm, ostium minimal average diameter: 17.7 ± 3.5 mm). Nine out of 11 (81.8%) LCPVs were successfully occluded and isolated at the ostium with a VGLA-guided PVI. The ablation procedure time was significantly shorter in the patients with than without an LCPV (61.5 ± 15.4 versus 86.9 ± 32.9 minutes, P = 0.01). There was no difference regarding the atrial tachyarrhythmia recurrence between those with and without an LCPV (P = 0.18). A total of 15 patients underwent a redo procedure, but reconnections were not observed in any of the LCPV patients.The VGLA-guided PVI was a useful therapeutic tool even in patients with an LCPV. The presence of an LCPV might not be associated with an increased risk of any atrial tachyarrhythmia recurrence.


Assuntos
Fibrilação Atrial , Terapia a Laser , Veias Pulmonares , Humanos , Veias Pulmonares/cirurgia , Átrios do Coração , Fibrilação Atrial/cirurgia , Lasers
11.
J Cardiovasc Electrophysiol ; 32(7): 1803-1811, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33969567

RESUMO

BACKGROUND: Contrast computed tomography (CT) is a useful tool for the detection of intracardiac thrombi. We aimed to assess the accuracy of the late-phase prone-position contrast CT (late-pCT) for thrombus detection in patients with persistent or long-standing persistent atrial fibrillation (AF). METHODS: Early and late-phase pCT were performed in 300 patients with persistent or long-standing AF. If late-pCT did not show an intracardiac contrast defect (CD), catheter ablation (CA) was performed. Immediately before CA, intracardiac echocardiography (ICE) from the left atrium was performed to confirm thrombus absence and the estimation of the blood velocity of the left atrial appendage (LAA). For patients with CDs on late-pCT, CA performance was delayed, and late-pCT was performed again after several months following oral anticoagulant alterations or dosage increases. RESULTS: Of the 40 patients who exhibited CDs in the early phase of pCT, six showed persistent CDs on late-pCT. In the remaining 294 patients without CDs on late-pCT, the absence of a thrombus was confirmed by ICE during CA. In all six patients with CD-positivity on late-pCT, the CDs vanished under the same CT conditions after subsequent anticoagulation therapy, and CA was successfully performed. Furthermore, the presence of residual contrast medium in the LAA on late-pCT suggested a decreased blood velocity in the LAA ( ≤ 15 cm/s) (sensitivity = 0.900 and specificity = 0.621). CONCLUSIONS: Late-pCT is a valuable tool for the assessment of intracardiac thrombi and LAA dysfunction in patients with persistent or long-standing persistent AF before CA.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Ablação por Cateter , Trombose , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Ecocardiografia Transesofagiana , Humanos , Decúbito Ventral , Trombose/diagnóstico por imagem , Trombose/etiologia , Tomografia Computadorizada por Raios X
12.
Circ J ; 85(3): 275-282, 2021 02 25.
Artigo em Inglês | MEDLINE | ID: mdl-33536386

RESUMO

BACKGROUND: Pulmonary vein (PV) isolation (PVI) with balloon-based visually guided laser ablation (VGLA) is useful for treating atrial fibrillation (AF), but phrenic nerve injury (PNI) is an important complication. We investigated the predictors of developing PNI during VGLA.Methods and Results:We included 130 consecutive patients who underwent an initial VGLA of non-valvular paroxysmal AF. Twenty patients developed PNI during the PVI. The patients with PNI had a significantly larger right superior PV ostial area (RSPVOA) than the other patients (mean [±SD] 284.7±47.0 vs. 233.1±46.4 mm2, respectively; P<0.01). Receiver operating characteristic analyses revealed that the area under the RSPVOA curve was 0.79 (95% confidence interval [CI] 0.69-0.90) with an optimal cut-off point of 238.0 mm2(sensitivity, 0.58; specificity, 0.95). In multivariate analyses, a large RSPVOA (HR 1.02, 95% CI 1.01-1.03, P<0.01) and small balloon size (HR 0.70, 95% CI 0.50-0.99, P=0.04) were independent risk factors for PNI during VGLA. PNI remained in 13 patients after the procedure, but 12 of these patients recovered from the PNI during the follow-up period. CONCLUSIONS: The incidence of PNI during VGLA was relatively high, but PNI improved in most cases. A large RSPVOA and small balloon size were predictors of PNI during VGLA.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Terapia a Laser , Traumatismos dos Nervos Periféricos , Nervo Frênico/lesões , Veias Pulmonares , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Humanos , Traumatismos dos Nervos Periféricos/etiologia , Veias Pulmonares/cirurgia , Resultado do Tratamento
13.
Int Heart J ; 62(2): 298-304, 2021 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-33731524

RESUMO

Radiofrequency and cryoballoon applications around the pulmonary veins (PVs) could provoke a vagal reflex (VR) by modulating the intrinsic cardiac autonomic nervous system (ICANS).This study aimed to investigate the incidence, timing, and clinical impact of a VR provoked by a laser balloon application for a PV isolation (PVI).A total of 92 consecutive paroxysmal atrial fibrillation (PAF) patients underwent a laser balloon PVI of PAF. Acute changes in the heart rate and blood pressure were recorded. The heart rate variability (HRV) was tested by Holter ECGs before and at three months following the ablation. Three hundred forty-five out of 363 PVs were successfully isolated (97%) with laser balloon applications. A VR such as sinus bradycardia (26.1%), transient sinus arrest (9.8%), transient atrioventricular block (1.1%), or a blood pressure reduction (8.7%) was observed during the laser balloon applications for the PVI. The follow-up ended at 12 months. The HRV attenuation was comparable before and at three months after the ablation procedure between that with and without a VR (P = 0.14). The PAF recurrence rate was also comparable between the two groups (P = 0.882).The laser balloon PVI often provoked a VR, however, the modulation of the ICANS was temporary and for up to three months as measured by the HRV changes after the ablation, and the freedom from any atrial fibrillation recurrence was comparable regardless of the occurrence of a VR.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Frequência Cardíaca/fisiologia , Terapia a Laser/métodos , Taquicardia Paroxística/cirurgia , Nervo Vago/fisiopatologia , Idoso , Fibrilação Atrial/fisiopatologia , Eletrocardiografia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Taquicardia Paroxística/fisiopatologia , Fatores de Tempo
14.
Int Heart J ; 62(2): 320-328, 2021 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-33731538

RESUMO

Second-generation cryoballoon (CB) ablation is effective in achieving pulmonary vein (PV) isolation (PVI) in atrial fibrillation (AF) patients. The "crosstalk" (CST) phenomenon has been reported to reduce unnecessary applications during CB ablation. Nevertheless, it is unclear under what conditions the CST phenomenon occurs.To seek the predictors of the CST phenomenon during CB-guided PVI, CST phenomenon in achieving ipsilateral superior PVI during inferior PV ablation was analyzed in AF patients who underwent de novo ablation using CB. CB occlusion status and nadir balloon temperature (NT) were compared in these patients, and all ablated superior PVs were categorized into three groups according to the necessity of the touch up ablation and effectiveness of the phenomenon.Of 1082 superior PVs, 16, 40, and 1026 were classified into the CST success, CST failure, and control groups (unnecessary CST), respectively. The proportion of superior PVs ablated with complete occlusion using the CB was significantly higher in the CST success group than in the other two groups. The proportion of superior PVs ablated with NT ≤ -46°C was higher in the CST success group than in the CST failure group. The CST phenomenon was always observed if CB ablation of the superior PVs was performed with both complete occlusion and NT ≤ -46°C and was almost always ineffective if it did not meet these two criteria (sensitivity, 100%; specificity, 93%).Successful CST ablation was highly predicted if complete PV occlusion and NT ≤ -46°C during CB ablation of the superior PVs were achieved.


Assuntos
Fibrilação Atrial/cirurgia , Criocirurgia/métodos , Sistema de Condução Cardíaco/fisiopatologia , Veias Pulmonares/cirurgia , Idoso , Fibrilação Atrial/fisiopatologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
15.
J Cardiovasc Electrophysiol ; 31(4): 875-884, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32017303

RESUMO

INTRODUCTION: Pulmonary vein isolation (PVI) and linear ablation with a roof line and bottom line on the left atrial (LA) posterior wall (LAPW) can be achieved with a cryoballoon (CB). This study sought to investigate the long-term durability of these linear lesions. METHODS AND RESULTS: Among 290 persistent patients with atrial fibrillation (AF) who had undergone linear ablation with a CB on the roof and bottom line of the LAPW in addition to the PVI, we analyzed those patients who underwent a re-do AF ablation. Arrhythmia recurrence was confirmed in 70 (24%) out of 290 patients, and 47 (16%) patients underwent re-do sessions. At the beginning of the re-do ablation, we examined the reconnection sites of the linear lesions on the LAPW and PVI. Maintenance of the conduction block on the LAPW roof and bottom lines was observed in 35 out of 47 patients (74.5%), and 16 out of 35 patients (45.7%), respectively. The length of the roof line was significantly shorter in patients with preservation of the conduction block on the LAPW roof than in those without (36.2 ± 6.5 mm vs 41.6 ± 4.7 mm, P = .02). CONCLUSION: Durable lesions could be obtained after linear ablation with the CB for the LAPW roof line, especially in those with a relatively short LAPW roof line. However, patients requiring touch-up ablation with radiofrequency were included, and that was associated with a potential financial implication.


Assuntos
Fibrilação Atrial/cirurgia , Criocirurgia , Veias Pulmonares/cirurgia , Potenciais de Ação , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Ablação por Cateter , Criocirurgia/efeitos adversos , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/fisiopatologia , Recidiva , Reoperação , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
16.
Pacing Clin Electrophysiol ; 43(1): 47-53, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31707738

RESUMO

PURPOSE: The aim of this study was to test regional pharmacological effects of an antiarrhythmic agents to predict ablative effects. BACKGROUND: The vein of Marshall (VOM) providing vascular access to myocardial tissue has been used for ablative purposes using ethanol. METHODS: A total of 35 patients (male 21, 63.2 ± 7.8 years old) were included. A balloon-tipped infusion catheter was inserted into the VOM. Endocardial ultrahigh-resolution mapping was performed along the VOM region to record the change in atrial electrograms (AEs) after VOM injection of cibenzoline of 3.5 mg during sustained atrial fibrillation (AF). Subsequently, ethanol was infused into the VOM and ablative region was mapped. RESULTS: In 17 patients (49 %), cibenzoline reduced AEs amplitude by >50%, all of which had also complete elimination of AEs following ethanol (Group A). In 18 patients (Group B), cibenzoline failed to eliminate AEs; yet, in 13 of 18 AEs were eliminated by ethanol. In the remaining five patients, ethanol did not eliminate AE. CONCLUSIONS: Cibenzoline into the VOM could reliably predicts the results of subsequent ethanol infusion into the VOM using ultrahigh-resolution mapping system, which leads to avoid unnecessary permanent lesion creation by ethanol infusion.


Assuntos
Antiarrítmicos/farmacologia , Fibrilação Atrial/terapia , Vasos Coronários , Etanol/farmacologia , Imidazóis/farmacologia , Idoso , Ablação por Cateter/métodos , Meios de Contraste , Angiografia Coronária , Eletrocardiografia , Feminino , Fluoroscopia , Humanos , Infusões Intravenosas , Masculino , Pessoa de Meia-Idade , Flebografia
17.
Int Heart J ; 61(2): 249-253, 2020 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-32173706

RESUMO

Cryoballoon ablation is an established catheter-based approach to treat atrial fibrillation (AF). However, thromboembolic events cannot be avoided during cryoablation. There is little data regarding the blood coagulation status during freezing.The thrombin antithrombin complex (TAT) and prothrombin fragment 1+2 (F 1+2) of patient blood were measured during cryoballoon application when the cryoballoon temperature reached the nadir in 63 AF patients. TAT was also measured from porcine blood during cryoballoon freezing in 5 pigs.The TAT and F 1+2 increased from 6.60 ± 5.65 to 9.16 ± 7.28 ng/mL (P = 0.004) and from 279.6 ± 146.4 to 323.6 ± 169.1 pmol/L (P = 0.003) between the control and during freezing, respectively. The TAT increased from 0.46 to 0.87 ng/mL during freezing compared to that of pre-freezing (P < 0.05), and it returned to 0.39 ng/mL in 30 minutes after an intravenous edoxaban administration (N.S.).Dabigatran failed to exert sufficient anticoagulant effects during cryofreezing. In contrast, intravenous edoxaban seemed to provoke anticoagulation effects under extreme low temperature circumstances.


Assuntos
Antitrombinas/uso terapêutico , Criocirurgia/efeitos adversos , Dabigatrana/uso terapêutico , Piridinas/uso terapêutico , Tiazóis/uso terapêutico , Tromboembolia/etiologia , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tromboembolia/prevenção & controle
18.
Int Heart J ; 61(1): 121-127, 2020 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-31956142

RESUMO

Laserballoon-based pulmonary vein isolation has proven to be safe and effective. However, the influence of the laser energy titration on the lesion formation has never been fully investigated. The aim of this study was to determine the relationship between the delivered laser energy and lesion size, as well as the incidence of steam pop.The whole porcine heart was excised, and the left ventricular myocardium was separated into four specimens. Myocardial specimens were embedded in a warm mattress to keep the myocardial temperature around 37°C. The laserballoon was located so that the surface of the laserballoon was attached to the myocardium. The laser energy was irradiated against the surface of myocardium at 5.5, 8.5, 10.0, and 12.0 W for 3, 5, 10, and 20 seconds. The depth, surface area, and lesion volume were measured using a digital vernier caliper.At constant laser energy and time, the lesion size increased significantly with the increasing energy (P < 0.001) and application duration (P < 0.001). The steam pop was provoked when a 12.0 W laser energy was applied for longer than 16 seconds, and it occurred in 2 out of 8 lesions.The laserballoon demonstrated the ability to create a lesion formation in a dose- and time-dependent manner. Steam pop could be provoked with high-energy irradiation.


Assuntos
Procedimentos Cirúrgicos Cardíacos/instrumentação , Ablação por Cateter/instrumentação , Animais , Suínos , Fatores de Tempo
19.
J Cardiovasc Electrophysiol ; 30(4): 528-537, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30656771

RESUMO

INTRODUCTION: Adenosine triphosphate (ATP) sensitive atrial tachycardia (AT) has been treated by radiofrequency catheter ablation. Cryofreezing energy has emerged as a novel energy source for catheter ablation. The aim of this study was to investigate the efficacy and safety of cryofreezing ablation for ATP-sensitive AT. METHODS AND RESULTS: A total of six patients with ATP-sensitive ATs were included in this study. A single atrial extrastimulation was able to initiate and terminate these ATs in all six patients. The electrophysiological findings satisfied the diagnostic criteria of ATP-sensitive AT. The ablation catheter was located at the earliest activation site of atrial excitation during the AT, and cryofreezing energy was delivered through a cryoablation catheter to perform cryomapping at temperature of -30 or -80°C. When cryomapping successfully terminated the ATs, cryoablation at a temperature of -80°C was subsequently performed. The earliest atrial activation during AT was recorded at the Koch's triangle area associated with a distinct intra-atrial activation sequence from that recorded during ventricular pacing. Cryoablation was performed at successful cryomapping sites and resulted in the complete elimination of the AT in all six patients without affecting the bidirectional atrioventricular (AV) nodal conduction. CONCLUSION: Cryofreezing energy was safe and effective in treating ATP-sensitive ATs even in patients with its origins located in the vicinity of the AV node.


Assuntos
Trifosfato de Adenosina/administração & dosagem , Criocirurgia , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas , Frequência Cardíaca , Taquicardia Supraventricular/cirurgia , Potenciais de Ação , Adulto , Idoso , Criocirurgia/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/fisiopatologia , Fatores de Tempo , Resultado do Tratamento
20.
J Cardiovasc Electrophysiol ; 30(6): 805-814, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30767365

RESUMO

INTRODUCTION: The left atrial (LA) posterior wall (LAPW) has been targeted to improve the clinical outcomes in patients with persistent atrial fibrillation (PersAF). This study aimed to investigate the feasibility, safety, and clinical implications of cryoballoon (CB) applications on the LAPW to accomplish electrical isolation (EI) of the LAPW with CB. METHODS: A total of 100 patients (males, 84; mean age, 64 ± 10 years) with PersAF were enrolled. The first 50 patients underwent only pulmonary vein isolation (PVI) (PVI-only group) and the remaining 50 patients underwent PVI and EI of the LAPW with CB (EI-LAPW group). RESULTS: One-year sinus rhythm maintenance probability was significantly higher in the EI-LAPW group than in PVI-only group (80.0% vs 55.1%, P = 0.01). The success rate of constructing an LA roof block line (LA-RB), bottom block line, and EI of the LAPW was 92%, 60%, and 58%, respectively. The nadir CB temperature (-45°C ± 4°C vs -39°C ± 5°C, P = 0.005) and anatomical angle of the left atrial roof (106°C ± 30°C vs 144°C ± 17°C, P < 0.001) significantly predicted the successful LA-RB construction. The left ventricular ejection fraction was significantly higher in unsuccessful cases than in successful cases of an EI of the LAPW (64% ± 8% vs 58% ± 11%, P = 0.041). Even though the EI of the LAPW was unsuccessful, CB freezing in LAPW significantly debulked the nonscar area (≥0.1 mV) in LAPW (18.1 ± 5.6 vs 2.2 ± 3.1 cm 2 , P < 0.001) and provided the equivalent 1-year outcome of successful cases (79.3% vs 81.0%, P = 0.90). CONCLUSION: The combination of PVI and EI of the LAPW with CB provided better clinical outcomes than conventional PVI procedure for patients with PersAF.


Assuntos
Fibrilação Atrial/cirurgia , Função do Átrio Esquerdo , Remodelamento Atrial , Criocirurgia , Átrios do Coração/cirurgia , Veias Pulmonares/cirurgia , Potenciais de Ação , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Criocirurgia/efeitos adversos , Estudos de Viabilidade , Feminino , Átrios do Coração/fisiopatologia , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/fisiopatologia , Recidiva , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa