Am J Otolaryngol ; 45(4): 104366, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38729016

RESUMO

PURPOSE: This study investigated dimension changes of various nasopharyngeal airways, including a novel self-supporting device, after saline submersion at body temperature to simulate in-vivo use. Dimension changes over time may reduce efficacy during long-term use and require sizing adjustments or limits on duration of use. MATERIALS AND METHODS: Cuffless Covidien endotracheal tubes, pediatric Rusch fixed flange polyvinyl chloride nasal airway tubes, pediatric Rusch Robertazzi style Mediprene nasal airway tubes, and novel silicone elastomer self-supporting nasopharyngeal airways were fully submerged in 0.9 % normal saline solution incubated at 37 degrees Celsius for 15 days. All devices had tube length and wall thickness measured after 0, 1, 2, 3, 4, 5, 10, and 15 days. The 95 % confidence intervals of tube dimensions at each date were compared with the 95 % confidence intervals at day 0. RESULTS: The Covidien ET tube, Rusch PVC NPA, and ssNPA tube lengths and wall thicknesses did not change significantly over 15 days. The Rusch Mediprene NPAs had a statistically significant increase in length starting at day 1 and wall thickness at day 2. CONCLUSIONS: The novel ssNPA did not expand in the in-vitro environment, supporting its safety for extended use. The PVC NPA and ET tube dimensions also remained stable. However, the Rusch Mediprene NPAs had significant length expansion after 1 day of submersion, indicating a considerable risk of expansion during extended use with potential implications for patient care. Silicone and PVC NPA dimensions remained stable when saturated, indicating these materials may be more appropriate for extended use.


Assuntos
Temperatura Corporal , Nasofaringe , Impressão Tridimensional , Solução Salina , Humanos , Desenho de Equipamento , Intubação Intratraqueal/instrumentação , Intubação Intratraqueal/métodos
2.
J Ultrasound Med ; 41(11): 2755-2766, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35170801

RESUMO

OBJECTIVES: Ultrasound is useful in predicting arteriovenous fistula (AVF) maturation, which is essential for hemodialysis in end-stage renal disease patients. We developed ultrasound software that measures circumferential vessel wall strain (distensibility) using conventional ultrasound Digital Imaging and Communications in Medicine (DICOM) data. We evaluated user-induced variability in measurement of arterial wall distensibility and upon finding considerable variation we developed and tested 2 methods for semiautomated measurement. METHODS: Ultrasound scanning of arteries of 10 subjects scheduled for AVF surgery were performed. The top and bottom of the vessel wall were tracked using the Kanade-Lucas-Tomasi (KLT) feature-tracking algorithm over the stack of images in the DICOM cine loops. The wall distensibility was calculated from the change of vessel diameter over time. Two semiautomated methods were used for comparison. RESULTS: The location of points selected by users for the cine loops varied significantly, with a maximum spread of up to 120 pixels (7.8 mm) for the top and up to 140 pixels (9.1 mm) for the bottom of the vessel wall. This variation in users' point selection contributed to the variation in distensibility measurements (ranging from 5.63 to 41.04%). Both semiautomated methods substantially reduced variation and were highly correlated with the median distensibility values obtained by the 10 users. CONCLUSIONS: Minimizing user-induced variation by standardizing point selection will increase reproducibility and reliability of distensibility measurements. Our recent semiautomated software may help expand use in clinical studies to better understand the role of vascular wall compliance in predicting the maturation of fistulas.


Assuntos
Derivação Arteriovenosa Cirúrgica , Falência Renal Crônica , Humanos , Reprodutibilidade dos Testes , Diálise Renal/métodos , Software
3.
J Stroke Cerebrovasc Dis ; 29(11): 105205, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33066901

RESUMO

BACKGROUND: As access to patient emboli is limited, embolus analogs (EAs) have become critical to the research of large vessel occlusion (LVO) stroke and the development of thrombectomy technology. To date, techniques for fabricating standardized human blood-derived EAs are limited in the variety of compositions, and the mechanical properties relevant to thrombectomy are not quantified. METHODS: EAs were made by mixing human banked red blood cells (RBCs), plasma, and platelet concentrate in 10 different volumetric percentage combinations to mimic the broad range of patient emboli causing LVO strokes. The samples underwent histologic analysis and tensile testing to mimic the pulling action of thrombectomy devices, and were compared to patient emboli. RESULTS: EAs had histologic compositions of 0-96% RBCs, 0.78%-92% fibrin, and 2.1%-22% platelets, which can be correlated with the ingredients using a regression model. At fracture, EAs elongated from 81% to 136%, and the ultimate tensile stress ranged from 16 to 949 kPa. These EAs' histologic compositions and tensile properties showed great similarity to those of emboli retrieved from LVO stroke patients, indicating the validity of such EA fabrication methods. EAs with lower RBC and higher fibrin contents are more extensible and can withstand higher tensile stress. CONCLUSIONS: EAs fabricated and tested using the proposed new methods provide a platform for stroke research and pre-clinical development of thrombectomy devices.


Assuntos
Plaquetas/metabolismo , Eritrócitos/metabolismo , Fibrina/metabolismo , Embolia Intracraniana/sangue , Plasma/metabolismo , Acidente Vascular Cerebral/sangue , Pesquisa Translacional Biomédica/métodos , Fenômenos Biomecânicos , Plaquetas/patologia , Eritrócitos/patologia , Humanos , Embolia Intracraniana/patologia , Estresse Mecânico , Acidente Vascular Cerebral/patologia , Resistência à Tração
4.
Cancer ; 124(12): 2607-2620, 2018 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-29624648

RESUMO

BACKGROUND: Central nervous system Langerhans cell histiocytosis (CNS-LCH) brain involvement may include mass lesions and/or a neurodegenerative disease (LCH-ND) of unknown etiology. The goal of this study was to define the mechanisms of pathogenesis that drive CNS-LCH. METHODS: Cerebrospinal fluid (CSF) biomarkers including CSF proteins and extracellular BRAFV600E DNA were analyzed in CSF from patients with CNS-LCH lesions compared with patients with brain tumors and other neurodegenerative conditions. Additionally, the presence of BRAFV600E was tested in peripheral mononuclear blood cells (PBMCs) as well as brain biopsies from LCH-ND patients, and the response to BRAF-V600E inhibitor was evaluated in 4 patients with progressive disease. RESULTS: Osteopontin was the only consistently elevated CSF protein in patients with CNS-LCH compared with patients with other brain pathologies. BRAFV600E DNA was detected in CSF of only 2/20 (10%) cases, both with LCH-ND and active lesions outside the CNS. However, BRAFV600E+ PBMCs were detected with significantly higher frequency at all stages of therapy in LCH patients who developed LCH-ND. Brain biopsies of patients with LCH-ND demonstrated diffuse perivascular infiltration by BRAFV600E+ cells with monocyte phenotype (CD14+ CD33+ CD163+ P2RY12- ) and associated osteopontin expression. Three of 4 patients with LCH-ND treated with BRAF-V600E inhibitor experienced significant clinical and radiologic improvement. CONCLUSION: In LCH-ND patients, BRAFV600E+ cells in PBMCs and infiltrating myeloid/monocytic cells in the brain is consistent with LCH-ND as an active demyelinating process arising from a mutated hematopoietic precursor from which LCH lesion CD207+ cells are also derived. Therapy directed against myeloid precursors with activated MAPK signaling may be effective for LCH-ND. Cancer 2018;124:2607-20. © 2018 American Cancer Society.


Assuntos
Neoplasias Encefálicas/diagnóstico , Histiocitose de Células de Langerhans/diagnóstico , Doenças Neurodegenerativas/diagnóstico , Osteopontina/líquido cefalorraquidiano , Proteínas Proto-Oncogênicas B-raf/genética , Adolescente , Adulto , Biomarcadores/sangue , Biomarcadores/líquido cefalorraquidiano , Biópsia , Encéfalo/patologia , Neoplasias Encefálicas/líquido cefalorraquidiano , Neoplasias Encefálicas/genética , Neoplasias Encefálicas/patologia , Criança , Pré-Escolar , Diagnóstico Diferencial , Feminino , Células-Tronco Hematopoéticas/patologia , Histiocitose de Células de Langerhans/líquido cefalorraquidiano , Histiocitose de Células de Langerhans/genética , Histiocitose de Células de Langerhans/patologia , Humanos , Lactente , Recém-Nascido , Leucócitos Mononucleares/patologia , Sistema de Sinalização das MAP Quinases , Masculino , Doenças Neurodegenerativas/líquido cefalorraquidiano , Doenças Neurodegenerativas/genética , Doenças Neurodegenerativas/patologia , Proteínas Proto-Oncogênicas B-raf/antagonistas & inibidores , Estudos Retrospectivos , Adulto Jovem
5.
J Therm Biol ; 71: 99-111, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29301706

RESUMO

Reducing brain temperature by head and neck cooling is likely to be the protective treatment for humans when subjects to sudden cardiac arrest. This study develops the experimental validation model and finite element modeling (FEM) to study the head and neck cooling separately, which can induce therapeutic hypothermia focused on the brain. Anatomically accurate geometries based on CT images of the skull and carotid artery are utilized to find the 3D geometry for FEM to analyze the temperature distributions and 3D-printing to build the physical model for experiment. The results show that FEM predicted and experimentally measured temperatures have good agreement, which can be used to predict the temporal and spatial temperature distributions of the tissue and blood during the head and neck cooling process. Effects of boundary condition, perfusion, blood flow rate, and size of cooling area are studied. For head cooling, the cooling penetration depth is greatly depending on the blood perfusion in the brain. In the normal blood flow condition, the neck internal carotid artery temperature is decreased only by about 0.13°C after 60min of hypothermia. In an ischemic (low blood flow rate) condition, such temperature can be decreased by about 1.0°C. In conclusion, decreasing the blood perfusion and metabolic reduction factor could be more beneficial to cool the core zone. The results also suggest that more SBC researches should be explored, such as the optimization of simulation and experimental models, and to perform the experiment on human subjects.


Assuntos
Temperatura Corporal , Encéfalo/fisiologia , Cabeça/fisiologia , Hipotermia Induzida , Modelos Teóricos , Pescoço/fisiologia , Encéfalo/irrigação sanguínea , Encéfalo/diagnóstico por imagem , Circulação Cerebrovascular , Análise de Elementos Finitos , Cabeça/irrigação sanguínea , Cabeça/diagnóstico por imagem , Parada Cardíaca/prevenção & controle , Humanos , Pescoço/irrigação sanguínea , Pescoço/diagnóstico por imagem , Imagens de Fantasmas , Impressão Tridimensional , Tomografia Computadorizada por Raios X
6.
J Clin Monit Comput ; 32(4): 699-705, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28965158

RESUMO

The American Society of Anesthesiologists Standards for Basic Monitoring recommends blood pressure (BP) measurement every 5 min. Research has shown distractions or technical factors can cause prolonged measurement intervals exceeding 5 min. We investigated the relationship between prolonged non-invasive BP (NIBP) measurement interval and the incidence of hypotension, detected post-interval. Our secondary outcome was to determine independent predictors of these prolonged NIBP measurement intervals. Retrospective data were analyzed from 139,509 general anesthesia cases from our institution's Anesthesia Information Management System (AIMS). Absolute hypotension (AH) was defined a priori as a systolic BP < 80 mmHg and relative hypotension (RH) was defined as a 40% decrease in systolic BP from the preoperative baseline. Odds ratios (OR) with 95% confidence intervals and Pearson's Chi square Test reported the association of prolonged NIBP measurement intervals on hypotension detected post-NIBP measurement interval. Logistic regression models were developed to determine independent predictors of NIBP measurement intervals. The analysis revealed that NIBP measurement intervals greater than 6 and 10 min are associated with an approximately four times higher incidence of a patient transitioning into hypotension (AH/RH > 6 min OR 4.0 / 3.6; AH/RH > 10 min OR 4.3 / 3.9; p < 0.001). A key finding was that the "> 10-minute AH model" indicated that age 41-80, increased co-morbidity profile, obesity and turning (repositioning) of the operative room table were significant predictors of prolonged NIBP measurement intervals (p < 0.001). While we do not suggest NIBP measurement intervals cause hypotension, intervals greater than 6 and 10 min are associated with a fourfold increase in the propensity of an undetected transition into both RH or AH. These data support current monitoring guidelines.


Assuntos
Determinação da Pressão Arterial/métodos , Hipotensão/diagnóstico , Hipotensão/etiologia , Complicações Intraoperatórias/diagnóstico , Complicações Intraoperatórias/etiologia , Monitorização Intraoperatória/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Determinação da Pressão Arterial/efeitos adversos , Determinação da Pressão Arterial/normas , Feminino , Humanos , Hipotensão/prevenção & controle , Complicações Intraoperatórias/prevenção & controle , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Monitorização Intraoperatória/efeitos adversos , Monitorização Intraoperatória/normas , Estudos Retrospectivos , Fatores de Tempo , Falha de Tratamento , Adulto Jovem
7.
Blood ; 124(19): 3007-15, 2014 Nov 06.
Artigo em Inglês | MEDLINE | ID: mdl-25202140

RESUMO

Langerhans cell histiocytosis (LCH) is a myeloproliferative disorder characterized by lesions composed of pathological CD207(+) dendritic cells with an inflammatory infiltrate. BRAFV600E remains the only recurrent mutation reported in LCH. In order to evaluate the spectrum of somatic mutations in LCH, whole exome sequencing was performed on matched LCH and normal tissue samples obtained from 41 patients. Lesions from other histiocytic disorders, juvenile xanthogranuloma, Erdheim-Chester disease, and Rosai-Dorfman disease were also evaluated. All of the lesions from histiocytic disorders were characterized by an extremely low overall rate of somatic mutations. Notably, 33% (7/21) of LCH cases with wild-type BRAF and none (0/20) with BRAFV600E harbored somatic mutations in MAP2K1 (6 in-frame deletions and 1 missense mutation) that induced extracellular signal-regulated kinase (ERK) phosphorylation in vitro. Single cases of somatic mutations of the mitogen-activated protein kinase (MAPK) pathway genes ARAF and ERBB3 were also detected. The ability of MAPK pathway inhibitors to suppress MAPK kinase and ERK phosphorylation in cell culture and primary tumor models was dependent on the specific LCH mutation. The findings of this study support a model in which ERK activation is a universal end point in LCH arising from pathological activation of upstream signaling proteins.


Assuntos
Histiocitose de Células de Langerhans/genética , Histiocitose de Células de Langerhans/metabolismo , MAP Quinase Quinase 1/genética , MAP Quinase Quinase 1/metabolismo , Proteínas Proto-Oncogênicas B-raf/genética , Proteínas Proto-Oncogênicas B-raf/metabolismo , Células Dendríticas/metabolismo , Progressão da Doença , Doença de Erdheim-Chester/genética , Doença de Erdheim-Chester/metabolismo , Células HEK293 , Histiocitose Sinusal/genética , Histiocitose Sinusal/metabolismo , Humanos , Sistema de Sinalização das MAP Quinases/genética , Mutação de Sentido Incorreto , Xantogranuloma Juvenil/genética , Xantogranuloma Juvenil/metabolismo
8.
Catheter Cardiovasc Interv ; 87(3): 376-80, 2016 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-26489781

RESUMO

OBJECTIVE: To assess the impact of simulation training on complications associated with femoral arterial access obtained by first year cardiology fellows. BACKGROUND: Prior studies demonstrate a higher incidence of arterial access related complications among patients undergoing invasive cardiac procedures. METHODS: First year cardiology fellows at four teaching hospitals in Michigan tracked their femoral access experience and any associated complications between July 2011 and June 2013. Fellows starting their academic training in July 2012 were first trained on a specially developed simulator before starting their rotation in the catheterization laboratory. The primary outcome was access proficiency, defined as five successful femoral access attempts without any complication or need to seek help from a more experienced team member. RESULTS: A total of 1,278 femoral access attempts were made by 21 fellows in 2011-2012 compared with 869 femoral access attempts made by 21 fellows in 2012-2013. There was a lower rate of access related complications in patients undergoing access attempts by first year fellows in year 2 compared with year 1 (2.1% versus 4.5%, P = 0.003). The number of procedures to achieve procedural proficiency was significantly higher in year 1 compared with year 2 (median 20 versus 10, P = 0.007). CONCLUSIONS: Incorporation of simulation in the training of first year fellows was associated with an improvement in proficiency and a clinically meaningful reduction in vascular complications.


Assuntos
Cateterismo Periférico/métodos , Educação de Pós-Graduação em Medicina/métodos , Artéria Femoral , Modelos Anatômicos , Modelos Cardiovasculares , Treinamento por Simulação/métodos , Cateterismo Periférico/efeitos adversos , Competência Clínica , Hospitais de Ensino , Humanos , Curva de Aprendizado , Michigan
9.
J Biomech Eng ; 137(4): 041004, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25480363

RESUMO

This research presents an experimental study evaluating stomach suturing using a precurved nickel-titanium (NiTi) guidewire for an endoscopic minimally invasive obesity treatment. Precise path planning is critical for accurate and effective suturing. A position measurement system utilizing a hand-held magnetic sensor was used to measure the shape of a precurved guidewire and to determine the radius of curvature before and after suturing. Ex vivo stomach suturing experiments using four different guidewire tip designs varying the radius of curvature and bevel angles were conducted. The changes in radius of curvature and suturing force during suturing were measured. A model was developed to predict the guidewire radius of curvature based on the measured suturing force. Results show that a small bevel angle and a large radius of curvature reduce the suturing force and the combination of small bevel angle and small radius of curvature can maintain the shape of guidewire for accurate suturing.


Assuntos
Fenômenos Mecânicos , Níquel , Suturas , Titânio , Animais , Teste de Materiais , Reprodutibilidade dos Testes , Estômago/cirurgia , Suínos
10.
J Pediatr ; 165(5): 990-6, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25441388

RESUMO

OBJECTIVE: To identify features associated with multisystem involvement and therapeutic failure in patients with skin Langerhans cell histiocytosis (LCH). STUDY DESIGN: We reviewed medical records of 71 consecutive patients with LCH with skin involvement evaluated at Texas Children's Hospital and analyzed clinical features, laboratory results, and the presence of circulating cells with the BRAF-V600E mutation with respect to initial staging and clinical outcomes. RESULTS: Skin disease in patients older than 18 months of age at diagnosis was associated with the presence of multisystem disease (OR, 9.65; 95% CI, 1.17-79.4). Forty percent of patients referred for presumed skin-limited LCH had underlying multisystem involvement, one-half of these with risk-organ involvement. Patients with skin-limited LCH had a 3-year progression-free survival of 89% after initial therapy, and none developed multisystem disease. Patients with skin/multisystem involvement had a 3-year progression-free survival of 44% with vinblastine/prednisone therapy, and risk-organ involvement did not correlate with failure to achieve nonactive disease. Circulating cells with BRAF-V600E were detected at higher frequency in patients with multisystem involvement (8 of 11 skin/multisystem vs 1 of 13 skin-limited; P = .002). CONCLUSION: Skin-limited LCH necessitates infrequent therapeutic intervention and has a lower risk of progression relative to skin plus multisystem LCH. The less-aggressive clinical course and lack of circulating cells with the BRAF-V600E mutation in skin-limited LCH suggest a different mechanism of disease origin compared with multisystem or risk-organ disease.


Assuntos
Histiocitose de Células de Langerhans/diagnóstico , Dermatopatias/diagnóstico , Adolescente , Criança , Pré-Escolar , Diagnóstico Diferencial , Progressão da Doença , Intervalo Livre de Doença , Feminino , Histiocitose de Células de Langerhans/terapia , Humanos , Lactente , Recém-Nascido , Masculino , Mutação , Dermatopatias/terapia , Análise de Sobrevida , Texas
12.
J Biomech Eng ; 136(6): 061001, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24658542

RESUMO

Bipolar electrosurgical vessel sealing is commonly used in surgery to perform hemostasis. The electrode compressive force is demonstrably an important factor affecting the vessel seal burst pressure, an index of the seal quality. Using a piezoresistive force sensor attached to the handle of a laparoscopic surgical device, applied handle force was measured and used to predict the electrosurgical vessel compressive force and the pressure at the electrode. The sensor enables the monitoring of vessel compressive force during surgery. Four levels of compressive force were applied to seal three types of porcine vessels (carotid artery, femoral artery, and jugular vein). The burst pressure of the vessel seal was tested to evaluate the seal quality. Compressive pressure was found to be a statistically significant factor affecting burst pressure for femoral arteries and jugular veins. Vessels sealed with low compressive pressure (<300 kPa) have a higher failure rate (burst pressure<100 mm Hg) than vessels sealed with high compressive pressure. An adequate compressive force is required to generate the compressive pressure needed to form a seal with high burst pressure. A laparoscopic surgical device with compressive force monitoring capability can help ensure adequate compressive pressure, vessel burst pressure, and quality of seal.


Assuntos
Vasos Sanguíneos , Eletrocirurgia/instrumentação , Fenômenos Mecânicos , Procedimentos Cirúrgicos Vasculares/instrumentação , Análise de Variância , Animais , Pressão , Suínos
13.
J Ultrasound Med ; 32(10): 1815-30, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24065263

RESUMO

This study investigated the use of ultrasound speckle decorrelation- and correlation-based lateral speckle-tracking methods for transverse and longitudinal blood velocity profile measurement, respectively. By studying the blood velocity gradient at the vessel wall, vascular wall shear stress, which is important in vascular physiology as well as the pathophysiologic mechanisms of vascular diseases, can be obtained. Decorrelation-based blood velocity profile measurement transverse to the flow direction is a novel approach, which provides advantages for vascular wall shear stress measurement over longitudinal blood velocity measurement methods. Blood flow velocity profiles are obtained from measurements of frame-to-frame decorrelation. In this research, both decorrelation and lateral speckle-tracking flow estimation methods were compared with Poiseuille theory over physiologic flows ranging from 50 to 1000 mm/s. The decorrelation flow velocity measurement method demonstrated more accurate prediction of the flow velocity gradient at the wall edge than the correlation-based lateral speckle-tracking method. The novelty of this study is that speckle decorrelation-based flow velocity measurements determine the blood velocity across a vessel. In addition, speckle decorrelation-based flow velocity measurements have higher axial spatial resolution than Doppler ultrasound measurements to enable more accurate measurement of blood velocity near a vessel wall and determine the physiologically important wall shear.


Assuntos
Algoritmos , Velocidade do Fluxo Sanguíneo/fisiologia , Vasos Sanguíneos/diagnóstico por imagem , Vasos Sanguíneos/fisiologia , Técnicas de Imagem por Elasticidade/métodos , Interpretação de Imagem Assistida por Computador/métodos , Ultrassonografia Doppler/métodos , Simulação por Computador , Técnicas de Imagem por Elasticidade/instrumentação , Humanos , Aumento da Imagem/métodos , Modelos Cardiovasculares , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Ultrassonografia Doppler/instrumentação
14.
Med Eng Phys ; 121: 104068, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37985025

RESUMO

GOAL: This work examines the use of a previously described piecewise continuous lumped muscle parameter (PPCLMP) model for predicting selected gait parameters for walking without and with ankle-foot orthoses (AFOs) of varying stiffnesses. METHODS: Two AFOs with low (3.4 Nm/deg) and high (6.9 Nm/deg) stiffnesses were tested on the left leg of six healthy subjects to examine the model prediction on the influence of different AFO stiffnesses on gait. RESULTS: The model prediction errors ranged from 0 % to 70 % for step lengths with root mean square error (RMSE) of 0.15 m and ranged from 0 % to 67 % for swing time with RMSE of 0.07 s. The prediction precision of step length was more consistent among subjects than of swing time. DISCUSSIONS AND CONCLUSIONS: The model predicts the observed shortened step lengths and swing times, but there were significant differences between predicted and observed swing times and step lengths. The causes of these differences might be differences in the lumped muscle parameters taken from the literature and those of the subjects tested. Also, the model assumption that muscle stiffness is proportional to joint angle may not be corrected.


Assuntos
Tornozelo , Órtoses do Pé , Humanos , Marcha/fisiologia , Caminhada/fisiologia , Articulação do Tornozelo , Músculos , Fenômenos Biomecânicos
15.
Med Eng Phys ; 113: 103969, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36966003

RESUMO

A miniature grinding wheel (0.85 mm diameter) was fabricated by nickel (Ni)-diamond electroplating on a thin (0.65 mm outer diameter) flexible hollow stainless steel drive shaft to remove the calcified plaque in coronary and peripheral arteries by atherectomy procedure. To coat electrically nonconductive diamond grits, the drive shaft was submerged in a pile of diamond grit during Ni electroplating. The electroplating current density and temperature were investigated for better surface finishing and Faraday efficiency. The electroplating time to obtain the designed coating thickness was modeled based on Faraday's law of electrolysis and the geometry of drive shaft, wheel, and diamond grit. To validate the miniature wheel performance in atherectomy, grinding experiments were conducted on an atherectomy cardiovascular simulator with a calcified plaque surrogate. The wheel motion, material removal rate, and wheel surface wear were studied via high-speed camera imaging and laser confocal microscopy. The grinding wheel with 80,000 rpm rotational speed had an orbital speed of 14,300 rpm around the 1.5 mm diameter plaque surrogate lumen. After grinding for 120 s, the plaque surrogate inner diameter was enlarged to 3.03 mm, and no wear or loss of diamond abrasive was observed on the grinding wheel. This study demonstrated that the proposed electroplating process for fabricating miniature grinding wheels could effectively remove the calcified plaque surrogate. This research could lead to a more effective and safer atherectomy device with sub-mm miniature diamond wheels to treat lesions deep in coronary and peripheral arteries.


Assuntos
Diamante , Galvanoplastia , Doença das Coronárias/fisiopatologia , Níquel , Angiografia Coronária/métodos , Coração
16.
Prosthet Orthot Int ; 47(3): 327-335, 2023 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-36952475

RESUMO

3D printing for custom prosthetic finger fabrication can have better fit and comfort than non-custom off-the-shelf ones while reducing fabrication labor time. The purpose of this case study was (1) to design and fabricate custom prosthetic fingers using 3D-printed molds for the treatment of partial finger amputation; (2) to evaluate patient satisfaction of the custom prosthetic fingers fabricated using 3D-printed molds and compare them to the custom prosthetic fingers fabricated through a conventional method of molding using plaster casts. The method to develop the custom prosthetic finger are as follows: (1) The shapes of the residual digits and contralateral fingers were acquired using a high-resolution 3D optical scanner. (2) Prosthetic fingers were designed by modifying the model of the residual digits and the contralateral fingers. (3) Molds of the prosthetic fingers were designed using computer-aided design software and fabricated by 3D printing. The study compared hand function tests and rehabilitation outcome surveys to evaluate the performance of the prosthetic fingers fabricated using 3D-printed molds and plaster casts. This case suggests that the prosthetic fingers fabricated using 3D-printed molds had comparable performance to the prosthetic fingers fabricated using plaster casts. The aesthetics and transparency of the prosthetic fingers contributed highly to the low satisfaction of the prosthetic fingers fabricated using 3D-printed molds.


Assuntos
Membros Artificiais , Dedos , Humanos , Impressão Tridimensional , Desenho Assistido por Computador , Satisfação do Paciente
17.
J Neural Eng ; 20(3)2023 05 15.
Artigo em Inglês | MEDLINE | ID: mdl-37141883

RESUMO

Objective.Carbon fiber (CF) is good for chronic neural recording due to the small diameter (7µm), high Young's modulus, and low electrical resistance, but most high-density carbon fiber (HDCF) arrays are manually assembled with labor-intensive procedures and limited by the accuracy and repeatability of the operator handling. A machine to automate the assembly is desired.Approach.The HDCF array assembly machine contains: (1) a roller-based CF extruder, (2) a motion system with three linear and one rotary stages, (3) an imaging system with two digital microscope cameras, and (4) a laser cutter. The roller-based extruder automatically feeds single CF as raw material. The motion system aligns the CF with the array backend then places it. The imaging system observes the relative position between the CF and the backend. The laser cutter cuts off the CF. Two image processing algorithms are implemented to align the CF with the support shanks and circuit connection pads.Main results.The machine was capable of precisely handling 6.8µm carbon fiber electrodes (CFEs). Each electrode was placed into a 12µm wide trenches in a silicon support shank. Two HDCF arrays with 16 CFEs populated on 3 mm shanks (with 80µm pitch) were fully assembled. Impedance measurements were found to be in good agreement with manual assembled arrays. One HDCF array was implanted in the motor cortex in an anesthetized rat and was able to detect single unit activity.Significance.This machine can eliminate the manual labor-intensive handling, alignment and placement of single CF during assembly, providing a proof-of-concepts towards fully automated HDCF array assembly and batch production.


Assuntos
Fenômenos Eletrofisiológicos , Ratos , Animais , Fibra de Carbono , Microeletrodos , Eletrodos Implantados , Impedância Elétrica
18.
J Vasc Access ; 24(4): 722-728, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34711097

RESUMO

BACKGROUND: The arteriovenous fistula (AVF) is the preferred vascular access for End Stage Renal Disease, having superior patency and lower infection risks than prosthetic graft and catheter access. When AVF dysfunction or delayed maturation does occur, the gold standard for diagnosis is the fistula angiogram (a.k.a. fistulogram). 3D ultrasound is available for obstetrical and other specialized uses, but it is cost prohibitive and has a field of view that is too small to cover the region of interest for the dialysis fistula application. We sought to develop a point of care 3D solution using freehand 2D ultrasound data acquisition. METHODS: We developed open-source software for 3D image reconstruction and projection of an angiogram-like image of the vascular access using a 2D freehand ultrasound scanner. We evaluated this software by comparing the ultrasound "sono-angiogram" images to fistulogram images in five subjects, using visual inspection and by applying the Percent of Exact Match (PEM) as a statistic test. RESULTS: The sono-angiograms showed identifiable characteristics that matched the fistulogram results in all five subjects. The PEM ranged between 42.8% and 77.0%, with Doppler and grayscale ultrasound data, showing complementary advantages and disadvantages when used for sono-angiogram image construction. Motion from freehand ultrasound acquisition was a significant source of mismatch. 3D image generation is a potential advantage with ultrasound data. CONCLUSIONS: While further work is needed to improve the accuracy with free hand scanning, fistulogram-like "sono-angiograms" can be generated using point of care 2D ultrasound. Methods such as these may be able to assist in point-of-care diagnosis in the future. The software is open-source, and importantly, the ultrasound data used are non-proprietary and available from any standard ultrasound machine. The simplicity and accessibility of this approach warrant further study.


Assuntos
Derivação Arteriovenosa Cirúrgica , Fístula , Humanos , Diálise Renal , Derivação Arteriovenosa Cirúrgica/efeitos adversos , Ultrassonografia Doppler , Software , Grau de Desobstrução Vascular
19.
J Trauma Acute Care Surg ; 94(1): 148-155, 2023 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-35687798

RESUMO

BACKGROUND: Gastroesophageal resuscitative occlusion of the aorta (GROA) has been shown effective in creating zone II aortic occlusion capable of temporarily improving survival in animal models of lethal noncompressible torso hemorrhage. In this study, tandem application of GROA transitioning to resuscitative endovascular balloon occlusion of the aorta (REBOA) is explored to demonstrate feasibility as a potential point-of-injury bridge to more advanced care, using a swine model of lethal abdominal hemorrhage. METHODS: Swine (n = 19) were anesthetized, instrumented, and subjected to a combination of controlled and uncontrolled hemorrhage from a grade-V liver laceration. Animals were designated as intervention (n = 9; GROA to REBOA) or control (n = 10), for 60 minutes. Following intervention, devices were deactivated, and animals received blood and crystalloid resuscitation. Animals were monitored for 4 hours. RESULTS: Injury resulted in onset of class IV shock in all animals with a mean arterial pressure (SD) of 24.5 (4.11) mm Hg at the start of intervention. Nine of 10 controls died during the intervention period with a median (interquartile) survival time of 8.5 (9.25) minutes. All animals receiving the intervention survived both the 60-minute intervention period demonstrating a significant survival improvement ( p = 0.0007). Transition from GROA to REBOA was successful in all animals with a transition time ranging from 30 to 90 seconds. Mean arterial pressure significantly improved in animals receiving GROA to REBOA for the duration of intervention, regardless of the method of aortic occlusion, with a range of 70.9 (16.04) mm Hg to 101.1 (15.3) mm Hg. Additional hemodynamics, metrics of shock, and oxygenation remained stable during intervention. CONCLUSION: Less invasive technologies such as GROA may present an opportunity to control noncompressible torso hemorrhage more rapidly, with a subsequent transition to more advanced care such as REBOA.


Assuntos
Oclusão com Balão , Procedimentos Endovasculares , Lacerações , Choque Hemorrágico , Suínos , Animais , Modelos Animais de Doenças , Aorta/lesões , Hemorragia/terapia , Fígado/lesões , Oclusão com Balão/métodos , Ressuscitação/métodos , Procedimentos Endovasculares/métodos , Choque Hemorrágico/terapia
20.
Med Phys ; 39(1): 99-108, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22225279

RESUMO

PURPOSE: To introduce and determine the biopsy length performance of the novel enhanced cutting edge (ECE) needle tip design, which contains high inclination angles that allow for more efficient tissue cutting. METHODS: ECE and regular two-plane symmetric needle tip's biopsy performance and cutting force are compared over a series of needle insertion experiments into bovine liver under varying levels of internal needle vacuum. An earlier developed needle tip force model is also applied. From these experiments and force model, the effect of needle tip geometry and vacuum on biopsy performance and force is studied. RESULTS: Biopsy sample length is on average 22%, 30%, and 49% longer for ECE needles compared to that of regular needles for the internal pressures of 0, -33.9, and -67.7 kPa, respectively. For ECE needles the vacuum level of -67.7 kPa produces on average biopsy lengths that are 41%, 31%, 29%, 45%, and 42% longer compared to no vacuum for two-plane needle tip bevel angles of 10°, 15°, 20°, 25°, and 30°, respectively. The force results show the ECE needle can be inserted with less initial insertion force than the regular two-plane needle for needles where the needle tip is fully contacting the tissue upon insertion. Vacuum is also showed to help lower insertion forces. CONCLUSIONS: The novel ECE needle tip design outperforms the regular two-plane symmetric needle by yielding longer biopsy samples and lower insertion forces, thereby demonstrating the benefits of needle geometries that contain higher inclination angles. The use of vacuum further improves the ECE needle tip biopsy sample length and lowers insertion forces.


Assuntos
Biópsia por Agulha/instrumentação , Fígado/citologia , Fígado/fisiologia , Agulhas , Animais , Bovinos , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento