Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Nature ; 577(7788): 89-94, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31894144

RESUMO

Screening mammography aims to identify breast cancer at earlier stages of the disease, when treatment can be more successful1. Despite the existence of screening programmes worldwide, the interpretation of mammograms is affected by high rates of false positives and false negatives2. Here we present an artificial intelligence (AI) system that is capable of surpassing human experts in breast cancer prediction. To assess its performance in the clinical setting, we curated a large representative dataset from the UK and a large enriched dataset from the USA. We show an absolute reduction of 5.7% and 1.2% (USA and UK) in false positives and 9.4% and 2.7% in false negatives. We provide evidence of the ability of the system to generalize from the UK to the USA. In an independent study of six radiologists, the AI system outperformed all of the human readers: the area under the receiver operating characteristic curve (AUC-ROC) for the AI system was greater than the AUC-ROC for the average radiologist by an absolute margin of 11.5%. We ran a simulation in which the AI system participated in the double-reading process that is used in the UK, and found that the AI system maintained non-inferior performance and reduced the workload of the second reader by 88%. This robust assessment of the AI system paves the way for clinical trials to improve the accuracy and efficiency of breast cancer screening.


Assuntos
Inteligência Artificial/normas , Neoplasias da Mama/diagnóstico por imagem , Detecção Precoce de Câncer/métodos , Detecção Precoce de Câncer/normas , Feminino , Humanos , Mamografia/normas , Reprodutibilidade dos Testes , Reino Unido , Estados Unidos
3.
JAMA Netw Open ; 6(1): e2248685, 2023 01 03.
Artigo em Inglês | MEDLINE | ID: mdl-36598790

RESUMO

Importance: Fetal ultrasonography is essential for confirmation of gestational age (GA), and accurate GA assessment is important for providing appropriate care throughout pregnancy and for identifying complications, including fetal growth disorders. Derivation of GA from manual fetal biometry measurements (ie, head, abdomen, and femur) is operator dependent and time-consuming. Objective: To develop artificial intelligence (AI) models to estimate GA with higher accuracy and reliability, leveraging standard biometry images and fly-to ultrasonography videos. Design, Setting, and Participants: To improve GA estimates, this diagnostic study used AI to interpret standard plane ultrasonography images and fly-to ultrasonography videos, which are 5- to 10-second videos that can be automatically recorded as part of the standard of care before the still image is captured. Three AI models were developed and validated: (1) an image model using standard plane images, (2) a video model using fly-to videos, and (3) an ensemble model (combining both image and video models). The models were trained and evaluated on data from the Fetal Age Machine Learning Initiative (FAMLI) cohort, which included participants from 2 study sites at Chapel Hill, North Carolina (US), and Lusaka, Zambia. Participants were eligible to be part of this study if they received routine antenatal care at 1 of these sites, were aged 18 years or older, had a viable intrauterine singleton pregnancy, and could provide written consent. They were not eligible if they had known uterine or fetal abnormality, or had any other conditions that would make participation unsafe or complicate interpretation. Data analysis was performed from January to July 2022. Main Outcomes and Measures: The primary analysis outcome for GA was the mean difference in absolute error between the GA model estimate and the clinical standard estimate, with the ground truth GA extrapolated from the initial GA estimated at an initial examination. Results: Of the total cohort of 3842 participants, data were calculated for a test set of 404 participants with a mean (SD) age of 28.8 (5.6) years at enrollment. All models were statistically superior to standard fetal biometry-based GA estimates derived from images captured by expert sonographers. The ensemble model had the lowest mean absolute error compared with the clinical standard fetal biometry (mean [SD] difference, -1.51 [3.96] days; 95% CI, -1.90 to -1.10 days). All 3 models outperformed standard biometry by a more substantial margin on fetuses that were predicted to be small for their GA. Conclusions and Relevance: These findings suggest that AI models have the potential to empower trained operators to estimate GA with higher accuracy.


Assuntos
Inteligência Artificial , Aprendizado de Máquina , Humanos , Gravidez , Feminino , Idade Gestacional , Reprodutibilidade dos Testes , Zâmbia , Ultrassonografia
4.
Nat Med ; 29(7): 1814-1820, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37460754

RESUMO

Predictive artificial intelligence (AI) systems based on deep learning have been shown to achieve expert-level identification of diseases in multiple medical imaging settings, but can make errors in cases accurately diagnosed by clinicians and vice versa. We developed Complementarity-Driven Deferral to Clinical Workflow (CoDoC), a system that can learn to decide between the opinion of a predictive AI model and a clinical workflow. CoDoC enhances accuracy relative to clinician-only or AI-only baselines in clinical workflows that screen for breast cancer or tuberculosis (TB). For breast cancer screening, compared to double reading with arbitration in a screening program in the UK, CoDoC reduced false positives by 25% at the same false-negative rate, while achieving a 66% reduction in clinician workload. For TB triaging, compared to standalone AI and clinical workflows, CoDoC achieved a 5-15% reduction in false positives at the same false-negative rate for three of five commercially available predictive AI systems. To facilitate the deployment of CoDoC in novel futuristic clinical settings, we present results showing that CoDoC's performance gains are sustained across several axes of variation (imaging modality, clinical setting and predictive AI system) and discuss the limitations of our evaluation and where further validation would be needed. We provide an open-source implementation to encourage further research and application.


Assuntos
Inteligência Artificial , Triagem , Reprodutibilidade dos Testes , Fluxo de Trabalho , Humanos
5.
Commun Med (Lond) ; 2: 128, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36249461

RESUMO

Background: Fetal ultrasound is an important component of antenatal care, but shortage of adequately trained healthcare workers has limited its adoption in low-to-middle-income countries. This study investigated the use of artificial intelligence for fetal ultrasound in under-resourced settings. Methods: Blind sweep ultrasounds, consisting of six freehand ultrasound sweeps, were collected by sonographers in the USA and Zambia, and novice operators in Zambia. We developed artificial intelligence (AI) models that used blind sweeps to predict gestational age (GA) and fetal malpresentation. AI GA estimates and standard fetal biometry estimates were compared to a previously established ground truth, and evaluated for difference in absolute error. Fetal malpresentation (non-cephalic vs cephalic) was compared to sonographer assessment. On-device AI model run-times were benchmarked on Android mobile phones. Results: Here we show that GA estimation accuracy of the AI model is non-inferior to standard fetal biometry estimates (error difference -1.4 ± 4.5 days, 95% CI -1.8, -0.9, n = 406). Non-inferiority is maintained when blind sweeps are acquired by novice operators performing only two of six sweep motion types. Fetal malpresentation AUC-ROC is 0.977 (95% CI, 0.949, 1.00, n = 613), sonographers and novices have similar AUC-ROC. Software run-times on mobile phones for both diagnostic models are less than 3 s after completion of a sweep. Conclusions: The gestational age model is non-inferior to the clinical standard and the fetal malpresentation model has high AUC-ROCs across operators and devices. Our AI models are able to run on-device, without internet connectivity, and provide feedback scores to assist in upleveling the capabilities of lightly trained ultrasound operators in low resource settings.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa