Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Anal Chem ; 92(6): 4512-4517, 2020 03 17.
Artigo em Inglês | MEDLINE | ID: mdl-32083471

RESUMO

A compact isotope ratio sensor based on laser absorption spectroscopy at 2.7 µm was developed for high precision and simultaneous measurements of the D/H, 18O/16O and 17O/16O isotope ratios in glacier water. Measurements of the oxygen and hydrogen isotope ratios in glacier water demonstrate a 1σ precision of 0.3‰ for δ18O, 0.2‰ for δ17O, and 0.5‰ for δ2H, respectively. The δ values of the working standard glacier water obtained by the calibrated sensor system is basically identical to the IRMS measurement results with a very high calibration accuracy from 0.17‰ to 0.75‰. Preliminary results on the reproducibility measurements display a standard deviation of 0.13‰ for δ18O, 0.13‰ for δ17O, and 0.64‰ for δ2H, respectively.

2.
Proteomics Clin Appl ; 14(3): e1900092, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-31999389

RESUMO

PURPOSE: Periodontal diseases, the most common chronic inflammatory diseases in humans, do not only affect tooth-supporting tissues but also other body parts by contributing to the development of life-threatening conditions. Since currently available diagnostic methods in periodontics lack the ability to identify patients at high risk for periodontal disease progression, development of innovative, non-invasive, rapid detection methods for diagnosing periodontal diseases is needed. This study aims to assess the potential of infrared attenuated total reflection (IR-ATR) spectroscopy to detect differences in composition of saliva supernatant in non-periodontitis individuals (control) and patients with generalized aggressive periodontitis (G-AgP). EXPERIMENTAL DESIGN: IR-ATR is performed with a wavelength interval from 1230 to 1180 cm-1 , analyzed with a simple subtraction in absorbance data. RESULTS: Ten samples show in the analysis of variance of the two data sets a true difference (99.8%). A principal component analysis (PCA) is able to discriminate between G-AgP and control groups. CONCLUSION AND CLINICAL RELEVANCE: This study demonstrates for the first time that IR-ATR spectroscopy is a promising tool for the analysis of saliva supernatant for the diagnosis of periodontitis, and potentially other periodontal conditions. IR-ATR spectroscopy holds the potential to be miniaturized and utilized as a non-invasive screening test.


Assuntos
Doenças Periodontais/metabolismo , Proteômica , Proteínas e Peptídeos Salivares/metabolismo , Espectrofotometria Infravermelho , Adulto , Análise de Variância , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doenças Periodontais/diagnóstico
3.
Spectrochim Acta A Mol Biomol Spectrosc ; 239: 118495, 2020 Oct 05.
Artigo em Inglês | MEDLINE | ID: mdl-32470812

RESUMO

Methane (CH4) and acetylene (C2H2) are important bioscience and chemical gases. The real-time monitoring and analysis of them have important research value in industrial process control. The time-sharing scanning assisted wavelength modulation spectroscopy (WMS) technique is developed for real-time and simultaneous detection of CH4 and C2H2. This system involves two near-infrared distributed feedback (DFB) lasers and a compact multipass cavity with an effective optical path of 52.2 m. The selected strong absorption lines of methane and acetylene are located at 6046.96 cm-1 and 6531.7 cm-1, respectively. The experiment environment is conducted at room temperature 23 °C and pressure 760 Torr. The sensor performance, including the minimum detection limit (MDL) and the stability, was improved by eliminating the influence of light intensity fluctuation using the WMS-2f/SAW technique. Allan deviation analysis indicates that a MDL of 0.1 ppm for CH4 and 0.2 ppm for C2H2 are achieved with 1-s integration time. And the instrument response time is about 44 s through the continuous analysis of standard gases. This sensitive, simple, reliable, and lowcost dual-gas sensor is very suitable for applications in the field environment, chemical process, and many other gas-phase analysis areas.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa