Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Eur Radiol ; 34(3): 1716-1723, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37644149

RESUMO

OBJECTIVES: To introduce an automated computational algorithm that estimates the global noise level across the whole imaging volume of PET datasets. METHODS: [18F]FDG PET images of 38 patients were reconstructed with simulated decreasing acquisition times (15-120 s) resulting in increasing noise levels, and with block sequential regularized expectation maximization with beta values of 450 and 600 (Q.Clear 450 and 600). One reader performed manual volume-of-interest (VOI) based noise measurements in liver and lung parenchyma and two readers graded subjective image quality as sufficient or insufficient. An automated computational noise measurement algorithm was developed and deployed on the whole imaging volume of each reconstruction, delivering a single value representing the global image noise (Global Noise Index, GNI). Manual noise measurement values and subjective image quality gradings were compared with the GNI. RESULTS: Irrespective of the absolute noise values, there was no significant difference between the GNI and manual liver measurements in terms of the distribution of noise values (p = 0.84 for Q.Clear 450, and p = 0.51 for Q.Clear 600). The GNI showed a fair to moderately strong correlation with manual noise measurements in liver parenchyma (r = 0.6 in Q.Clear 450, r = 0.54 in Q.Clear 600, all p < 0.001), and a fair correlation with manual noise measurements in lung parenchyma (r = 0.52 in Q.Clear 450, r = 0.33 in Q.Clear 600, all p < 0.001). Classification performance of the GNI for subjective image quality was AUC 0.898 for Q.Clear 450 and 0.919 for Q.Clear 600. CONCLUSION: An algorithm provides an accurate and meaningful estimation of the global noise level encountered in clinical PET imaging datasets. CLINICAL RELEVANCE STATEMENT: An automated computational approach that measures the global noise level of PET imaging datasets may facilitate quality standardization and benchmarking of clinical PET imaging within and across institutions. KEY POINTS: • Noise is an important quantitative marker that strongly impacts image quality of PET images. • An automated computational noise measurement algorithm provides an accurate and meaningful estimation of the global noise level encountered in clinical PET imaging datasets. • An automated computational approach that measures the global noise level of PET imaging datasets may facilitate quality standardization and benchmarking as well as protocol harmonization.


Assuntos
Processamento de Imagem Assistida por Computador , Tomografia por Emissão de Pósitrons , Humanos , Processamento de Imagem Assistida por Computador/métodos , Tomografia por Emissão de Pósitrons/métodos , Fluordesoxiglucose F18 , Fígado/diagnóstico por imagem , Algoritmos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Imagens de Fantasmas
2.
Eur Radiol ; 2023 Oct 19.
Artigo em Inglês | MEDLINE | ID: mdl-37855853

RESUMO

OBJECTIVES: To assess the evolution of administered radiotracer activity for F-18-fluorodeoxyglucose (18F-FDG) PET/CT or PET/MR in pediatric patients (0-16 years) between years 2000 and 2021. METHODS: Pediatric patients (≤ 16 years) referred for 18F-FDG PET/CT or PET/MR imaging of the body during 2000 and 2021 were retrospectively included. The amount of administered radiotracer activity in megabecquerel (MBq) was recorded, and signal-to-noise ratio (SNR) was measured in the right liver lobe with a 4 cm3 volume of interest as an indicator for objective image quality. Descriptive statistics were computed. RESULTS: Two hundred forty-three children and adolescents underwent a total of 466 examinations. The median injected 18F-FDG activity in MBq decreased significantly from 296 MBq in 2000-2005 to 100 MBq in 2016-2021 (p < 0.001), equaling approximately one-third of the initial amount. The median SNR ratio was stable during all years with 11.7 (interquartile range [IQR] 10.7-12.9, p = 0.133). CONCLUSIONS: Children have benefited from a massive reduction in the administered 18F-FDG dose over the past 20 years without compromising objective image quality. CLINICAL RELEVANCE STATEMENT: Radiotracer dose was reduced considerably over the past two decades of pediatric F-18-fluorodeoxyglucose PET/CT and PET/MR imaging highlighting the success of technical innovations in pediatric PET imaging. KEY POINTS: • The evolution of administered radiotracer activity for F-18-fluorodeoxyglucose (18F-FDG) PET/CT or PET/MR in pediatric patients (0-16 years) between 2000 and 2021 was assessed. • The injected tracer activity decreased by 66% during the study period from 296 megabecquerel (MBq) to 100 MBq (p < 0.001). • The continuous implementation of technical innovations in pediatric hybrid 18F-FDG PET has led to a steady decrease in the amount of applied radiotracer, which is particularly beneficial for children who are more sensitive to radiation.

3.
J Nucl Cardiol ; 30(1): 313-320, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-35301677

RESUMO

BACKGROUND: To assess the accuracy of fully automated deep learning (DL) based coronary artery calcium scoring (CACS) from non-contrast computed tomography (CT) as acquired for attenuation correction (AC) of cardiac single-photon-emission computed tomography myocardial perfusion imaging (SPECT-MPI). METHODS AND RESULTS: Patients were enrolled in this study as part of a larger prospective study (NCT03637231). In this study, 56 Patients who underwent cardiac SPECT-MPI due to suspected coronary artery disease (CAD) were prospectively enrolled. All patients underwent non-contrast CT for AC of SPECT-MPI twice. CACS was manually assessed (serving as standard of reference) on both CT datasets (n = 112) and by a cloud-based DL tool. The agreement in CAC scores and CAC score risk categories was quantified. For the 112 scans included in the analysis, interscore agreement between the CAC scores of the standard of reference and the DL tool was 0.986. The agreement in risk categories was 0.977 with a reclassification rate of 3.6%. Heart rate, image noise, body mass index (BMI), and scan did not significantly impact (p=0.09 - p=0.76) absolute percentage difference in CAC scores. CONCLUSION: A DL tool enables a fully automated and accurate estimation of CAC scores in patients undergoing non-contrast CT for AC of SPECT-MPI.


Assuntos
Doença da Artéria Coronariana , Aprendizado Profundo , Imagem de Perfusão do Miocárdio , Humanos , Cálcio , Imagem de Perfusão do Miocárdio/métodos , Estudos Prospectivos , Tomografia Computadorizada de Emissão de Fóton Único/métodos
4.
Eur Radiol ; 32(1): 508-516, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34156552

RESUMO

OBJECTIVES: To assess the frequency, intensity, and clinical impact of [18F]FDG-avidity of axillary lymph nodes after vaccination with COVID-19 vaccines BNT162b2 (Pfizer-BioNTech) and mRNA-1273 (Moderna) in patients referred for oncological FDG PET/CT. METHODS: One hundred forty patients referred for FDG PET/CT during February and March 2021 after first or second vaccination with Pfizer-BioNTech or Moderna were retrospectively included. FDG-avidity of ipsilateral axillary lymph nodes was measured and compared. Assuming no knowledge of prior vaccination, metastatic risk was analyzed by two readers and the clinical impact was evaluated. RESULTS: FDG PET/CT showed FDG-avid lymph nodes ipsilateral to the vaccine injection in 75/140 (54%) patients with a mean SUVmax of 5.1 (range 2.0 - 17.3). FDG-avid lymph nodes were more frequent in patients vaccinated with Moderna than Pfizer-BioNTech (36/50 [72%] vs. 39/90 [43%] cases, p < 0.001). Metastatic risk of unilateral FDG-avid axillary lymph nodes was rated unlikely in 52/140 (37%), potential in 15/140 (11%), and likely in 8/140 (6%) cases. Clinical management was affected in 17/140 (12%) cases. CONCLUSIONS: FDG-avid axillary lymph nodes are common after COVID-19 vaccination. The avidity of lymph nodes is more frequent in Moderna compared to that in Pfizer-BioNTech vaccines. To avoid relatively frequent clinical dilemmas, we recommend carefully taking the history for prior vaccination in patients undergoing FDG PET/CT and administering the vaccine contralateral to primary cancer. KEY POINTS: • PET/CT showed FDG-avid axillary lymph nodes ipsilateral to the vaccine injection site in 54% of 140 oncological patients after COVID-19 vaccination. • FDG-avid lymphadenopathy was observed significantly more frequently in Moderna compared to patients receiving Pfizer-BioNTech-vaccines. • Patients should be screened for prior COVID-19 vaccination before undergoing PET/CT to enable individually tailored recommendations for clinical management.


Assuntos
Vacinas contra COVID-19 , COVID-19 , Vacina de mRNA-1273 contra 2019-nCoV , Vacina BNT162 , Fluordesoxiglucose F18 , Humanos , Linfonodos/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Estudos Retrospectivos , SARS-CoV-2 , Vacinação
5.
J Nucl Cardiol ; 29(6): 3236-3247, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35175556

RESUMO

BACKGROUND: To assess whether low-dose CT for attenuation correction of myocardial perfusion single-photon emission computed tomography (SPECT) allows for identification of anemic patients and grading anemia severity. METHODS AND RESULTS: Patients who underwent a preoperative blood-test and low-dose CT scan, as a part of a cardiac SPECT exam, between 01 January 2015 and 31 December 2017 were enrolled in this retrospective study. Hemoglobin (Hb) levels and hematocrit were derived from clinical records. CT images were visually assessed (qualitative analysis) for the detection of inter-ventricular septum sign (IVSS) and aortic rim sign (ARS) and quantitative analysis were performed. The diagnostic accuracy for detecting anemia was compared using Hb values as the standard of reference. A total of 229 patients were included (110 with anemia; 57 mild; 46 moderate; 7 severe). The AUC of IVSS and ARS were 0.830 and 0.669, respectively (p<0.0001). The quantitative analysis outperformed ARS and IVSS; (AUC of 0.893, p=0.29). The optimal anemia cut-off using Youden index was 4.5 HU. CONCLUSION: Quantitative analysis derived from low-dose CT images, as a part of cardiac SPECT exams, have a diagnostic accuracy similar to that of hematocrit for the detection of anemia and may allow discriminating different anemia severities.


Assuntos
Anemia , Imagem de Perfusão do Miocárdio , Humanos , Estudos Retrospectivos , Sensibilidade e Especificidade , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tomografia Computadorizada por Raios X/métodos , Anemia/diagnóstico por imagem , Imagem de Perfusão do Miocárdio/métodos , Perfusão
6.
Eur Radiol ; 31(10): 8011-8020, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33768288

RESUMO

OBJECTIVES: To compare block sequential regularized expectation maximization (BSREM) and ordered subset expectation maximization (OSEM) for the detection of in-transit metastasis (ITM) of malignant melanoma in digital [18F]FDG PET/CT. METHODS: We retrospectively analyzed a cohort of 100 [18F]FDG PET/CT scans of melanoma patients with ITM, performed between May 2017 and January 2020. PET images were reconstructed with both OSEM and BSREM algorithms. SUVmax, target-to-background ratio (TBR), and metabolic tumor volume (MTV) were recorded for each ITM. Differences in PET parameters were analyzed with the Wilcoxon signed-rank test. Differences in image quality for different reconstructions were tested using the Man-Whitney U test. RESULTS: BSREM reconstruction led to the detection of 287 ITM (39% more than OSEM). PET parameters of ITM were significantly different between BSREM and OSEM reconstructions (p < 0.001). SUVmax and TBR were higher (76.5% and 77.7%, respectively) and MTV lower (49.5%) on BSREM. ITM missed with OSEM had significantly lower SUVmax (mean 2.03 vs. 3.84) and TBR (mean 1.18 vs. 2.22) and higher MTV (mean 2.92 vs. 1.01) on OSEM compared to BSREM (all p < 0.001). CONCLUSIONS: BSREM detects significantly more ITM than OSEM, owing to higher SUVmax, higher TBR, and less blurring. BSREM is particularly helpful in small and less avid lesions, which are more often missed with OSEM. KEY POINTS: • In melanoma patients, [18F]FDG PET/CT helps to detect in-transit metastases (ITM), and their detection is improved by using BSREM instead of OSEM reconstruction. • BSREM is particularly useful in small lesions.


Assuntos
Melanoma , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Algoritmos , Fluordesoxiglucose F18 , Humanos , Processamento de Imagem Assistida por Computador , Melanoma/diagnóstico por imagem , Compostos Radiofarmacêuticos , Estudos Retrospectivos
7.
Eur Radiol ; 30(5): 2922-2933, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32020398

RESUMO

OBJECTIVES: To compare interreader agreement and diagnostic accuracy of LI-RADS v2018 categorization using quantitative versus qualitative MRI assessment of arterial phase hyperenhancement (APHE) and washout (WO) of focal liver lesions. METHODS: Sixty patients (19 female; mean age, 56 years) at risk for HCC with 71 liver lesions (28 HCCs, 43 benign) who underwent contrast-enhanced MRI were included in this retrospective study. Four blinded radiologists independently assigned a qualitative LI-RADS score per lesion. Two other radiologists placed ROIs within the lesion, adjacent liver parenchyma, and paraspinal musculature on pre- and post-contrast MR images. The percentage of arterial enhancement and the liver-to-lesion contrast ratio were calculated for quantification of APHE and WO. Using these quantitative parameters, a quantitative LI-RADS score was assigned. Interreader agreement and AUCs were calculated. RESULTS: Interreader agreement was similar for qualitative and quantitative LI-RADS (κ = 0.38 vs. 0.40-0.47) with a tendency towards improved agreement for quantitatively assessed APHE (κ = 0.65 vs. 0.81) and WO (κ = 0.53 vs. 0.78). Qualitative LI-RADS showed an AUC of 0.86, 0.94, 0.94, and 0.91 for readers 1, 2, 3, and 4, respectively. The quantitative LI-RADS score where APHE/WO/or both were replaced showed an AUC of 0.89/0.84/0.89, 0.95/0.92/0.92, 0.93/0.91/0.89, and 0.91/0.86/0.88 for readers 1, 2, 3, and 4, respectively. Sensitivity of LR-4/5 slightly increased, while specificity slightly decreased using quantitative APHE. CONCLUSION: Qualitative and quantitative LI-RADS showed similar performance. Quantitatively assessed APHE showed the potential to increase interreader agreement and sensitivity of HCC diagnosis, whereas quantitatively assessed WO had the opposite effect and needs to be redefined. KEY POINTS: • Quantitative assessment of arterial phase hyperenhancement shows the potential to increase interreader agreement and sensitivity to diagnose hepatocellular carcinoma. • Adding quantitative measurements of major LI-RADS features does not improve accuracy over qualitative assessment alone according to the LI-RADS v2018 algorithm.


Assuntos
Carcinoma Hepatocelular/diagnóstico por imagem , Meios de Contraste , Aumento da Imagem/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Sistemas de Informação em Radiologia/estatística & dados numéricos , Adulto , Idoso , Algoritmos , Área Sob a Curva , Estudos de Avaliação como Assunto , Feminino , Humanos , Fígado/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade
8.
Diagnostics (Basel) ; 14(9)2024 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-38732338

RESUMO

BACKGROUND: The levator ani muscle (LAM) is crucial for pelvic floor stability, yet its quantitative MRI assessment is only a recent focus. Our study aims to standardize the quantitative analysis of the LAM morphology within the 3D Pelvic Inclination Correction System (3D-PICS). METHODS: We analyzed 35 static MR datasets from nulliparous women examining the pubovisceral (PVM), iliococcygeal (ICM), coccygeal (COC), and puborectal muscle (PRM). The PVM consists of three origin-insertion pairs, namely the puboanal (PAM), puboperineal (PPM) and pubovaginal muscle (PVaM). The analysis included a quantitative examination of the morphology of LAM, focusing on the median location (x/y/z) (x: anterior-posterior, y: superior-inferior, z: left-right) of the origin and insertion points (a), angles (b) and lengths (c) of LAM. Inter-rater reliability was calculated. RESULTS: Interindividual variations in 3D coordinates among muscle subdivisions were shown. In all, 93% of all origin and insertion points were found within an SD of <8 mm. Angles to the xz-plane range between -15.4° (right PRM) and 40.7° (left PAM). The PRM is the largest pelvic muscle in static MRI. The ICC indicated moderate-to-good agreement between raters. CONCLUSIONS: The accurate morphometry of the LAM and its subdivisions, along with reliable inter-rater agreement, was demonstrated, enhancing the understanding of normal pelvic anatomy in young nulliparous women.

9.
Abdom Radiol (NY) ; 49(6): 1996-2007, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38480546

RESUMO

PURPOSE: To define the normal range and threshold values for pathologic prolapse on MRI using the PICS line and assess its correlation with the pubococcygeal line (PCL). METHODS: This prospective, IRB-approved study included 20 nulliparous volunteers and 18 prolapse patients (POP-Q Stage ≥ 2). Organ positions (bladder, cervix, anorectal junction) relative to PICS and PCL were measured on dynamic MRI. Differences in organ position were compared. Receiver-operating characteristic (ROC) analysis was performed to identify cutoff values for prolapse using the PICS line. The correlation between PICS and PCL measurements was tested with Spearman's rank correlation. RESULTS: In volunteers, median bladder and cervix positions measured to the PICS at rest were - 2.7 cm and - 5.3 cm compared to - 1.9 cm and - 2.7 cm in patients (p < 0.001). During straining, bladder and cervix were at - 0.9 cm and - 3.2 cm in volunteers versus + 2.5 cm and + 2.5 cm in patients (p < 0.001). Correlation was strong for PICS and PCL measurements for all three compartments (δ = 0.883-0.970, p ≤ 0.001). AUCs of PICS for the anterior and middle compartment were 0.98 (95% confidence interval [CI] 0.96-1.00, p < 0.001) and 0.96 (95% CI 0.89-1.00, p < 0.001) for differentiating patients from healthy volunteers. AUC for the posterior compartment was 0.76 (95% CI 0.57-0.96, p = 0.034). CONCLUSION: PICS measurements reliably differentiate patients from volunteers in the anterior and middle compartment. Future studies need to identify a reliable threshold for the posterior compartment. PICS and PCL measurements are strongly correlated.


Assuntos
Imageamento por Ressonância Magnética , Prolapso de Órgão Pélvico , Humanos , Feminino , Prolapso de Órgão Pélvico/diagnóstico por imagem , Estudos Prospectivos , Imageamento por Ressonância Magnética/métodos , Adulto , Pessoa de Meia-Idade , Valores de Referência , Idoso
10.
Eur J Radiol ; 173: 111351, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38340570

RESUMO

PURPOSE: The aim of the MRI-study was to evaluate the visibility of the pelvic floor ligaments and to analyze the ligament morphometry in 3D space. METHODS: Twenty-two nulliparous women underwent MRI with a ligament specific protocol. MR datasets were evaluated using the 3D Pelvic Inclination Correction System (3D-PICS). The round ligament (RL), sacrospinous ligament (SSL), sacrotuberous ligament (STL), urogenital diaphragm (UGD) and uterosacral ligament (USL) were analyzed. Qualitative and quantitative analysis was performed. 3D coordinates for origin and insertion points were determined relative to the symphysis; subsequently lengths and angles were calculated. Interrater reliability was calculated to validate the point determination method. RESULTS: Moderate to good visibility was reported for the RL, the SSL, the STL and the UGD. Standard deviation of the points analyzed in the different dimensions vary from 1.5 mm to 21.3 mm. Origin and insertion points of the ligaments are found within a mean standard distance of 10.7 mm. The highest variability was seen in insertion points of RL, with a standard distance of 25.4 mm. The interrater reliability was good to very good (range of intraclass correlation coefficients (ICC) from 0.58 to 0.96), except for the UGD ventral points (ICC from 0.27 to 0.55). CONCLUSIONS: This in-vivo MRI technique development study offers first exact data describing the pelvic floor ligaments in nulliparous women in 3D-PICS. Visibility, exact 3D coordinates of the origin and insertion points, lengths, angles and interrater reliability assessed for all parameters were evaluated morphometrically.


Assuntos
Ligamentos , Diafragma da Pelve , Humanos , Feminino , Diafragma da Pelve/diagnóstico por imagem , Reprodutibilidade dos Testes , Ligamentos/diagnóstico por imagem , Ligamentos Articulares , Imageamento por Ressonância Magnética/métodos , Projetos de Pesquisa
11.
EJNMMI Res ; 14(1): 36, 2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38578516

RESUMO

BACKGROUND: Liver uptake in [68Ga]Ga-PSMA-11 PET is used as an internal reference in addition to clinical parameters to select patients for [177Lu]Lu-PSMA-617 radioligand therapy (RLT). Due to increased demand, [68Ga]Ga-PSMA-11 was replaced by [18F]F-PSMA-1007, a more lipophilic tracer with different biodistribution and splenic uptake was suggested as a new internal reference. We compared the intra-patient tracer distribution between [68Ga]Ga-PSMA-11 and [18F]F-PSMA-1007. METHODS: Fifty patients who underwent PET examinations in two centers with both [18F]F-PSMA-1007 and [68Ga]Ga-PSMA-11 within one year were included. Mean standardized uptake values (SUVmean) were obtained for liver, spleen, salivary glands, blood pool, and bone. Primary tumor, local recurrence, lymph node, bone or visceral metastasis were also assessed for intra- and inter-individual comparison. RESULTS: Liver SUVmean was significantly higher with [18F]F-PSMA-1007 (11.7 ± 3.9) compared to [68Ga]Ga-PSMA-11 (5.4 ± 1.7, p < .05) as well as splenic SUVmean (11.2 ± 3.5 vs.8.1 ± 3.5, p < .05). The blood pool was comparable between the two scans. Malignant lesions did not show higher SUVmean on [18F]F-PSMA-1007. Intra-individual comparison of liver uptake between the two scans showed a linear association for liver uptake with SUVmean [68Ga]Ga-PSMA-11 = 0.33 x SUVmean [18F]F-PSMA-1007 + 1.52 (r = .78, p < .001). CONCLUSION: Comparing biodistribution of [68Ga]Ga and [18F]F tracers, liver uptake on [68Ga]Ga-PSMA-11 PET is the most robust internal reference value. Liver uptake of [18F]F-PSMA-1007 was significantly higher, but so was the splenic uptake. The strong intra-individual association of hepatic accumulation between the two scans may allow using of a conversion factor for [18F]F-PSMA-1007 as a basis for RLT selection.

12.
Clin Nucl Med ; 49(8): 709-714, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38651767

RESUMO

BACKGROUND: The aim of our study was to retrospectively analyze FDG PET/CT data in patients with facial nerve palsy (FNP) for the presence of the monocle sign. PATIENTS AND METHODS: A total of 85 patients with unilateral FNP were included into our study, thereof 73 with peripheral FNP and 12 with central FNP. FDG uptake (SUV max , SUV mean , total lesion glycolysis) was measured in both orbicularis oculi muscles (OOMs). FDG uptake of paretic and nonparetic muscles was compared in patients with FNP (Wilcoxon test and Mann-Whitney U test) and was also compared with FDG uptake in 33 patients without FNP (Mann-Whitney U test). SUV max ratios of OOM were compared. A receiver operating characteristic curve and Youden Index were used to determine the optimal cutoff SUV max ratio for the prevalence of contralateral peripheral FNP. RESULTS: The SUV max ratio of OOM was significantly higher in patients with peripheral FNP compared with patients with central FNP and those without FNP (1.70 ± 0.94 vs 1.16 ± 0.09 vs 1.18 ± 0.21, respectively; P < 0.001). The SUV max ratio of OOM yielded an area under the curve (AUC) of 0.719 (95% confidence interval, 0.630-0.809), with an optimal cutoff of 1.41, yielding a specificity of 94.4% and a sensitivity of 44.1% for identifying contralateral peripheral FNP. One hundred percent specificity is achieved using a cutoff of 1.91 (sensitivity, 29.4%). CONCLUSIONS: Asymmetrically increased FDG uptake of the OOM (the "monocle sign") indicates contralateral peripheral FNP. A nearly 2-fold higher SUV max represents a practically useful cutoff.


Assuntos
Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Adulto , Paralisia Facial/diagnóstico por imagem , Idoso , Estudos Retrospectivos , Curva ROC , Tomografia por Emissão de Pósitrons
13.
Br J Radiol ; 96(1152): 20220482, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37751216

RESUMO

OBJECTIVES: To evaluate the evolution of CT radiation dose in pediatric patients undergoing hybrid 2-[18F]fluoro-2-deoxy-D-glucose (2-[18F]FDG) PET/CT between 2007 and 2021. METHODS AND MATERIALS: Data from all pediatric patients aged 0-18 years who underwent hybrid 2-[18F]FDG PET/CT of the body between January 2007 and May 2021 were reviewed. Demographic and imaging parameters were collected. A board-certified radiologist reviewed all CT scans and measured image noise in the brain, liver, and adductor muscles. RESULTS: 294 scans from 167 children (72 females (43%); median age: 14 (IQR 10-15) years; BMI: median 17.5 (IQR 15-20.4) kg/m2) were included. CT dose index-volume (CTDIvol) and dose length product (DLP) both decreased significantly from 2007 to 2021 (both p < 0.001, Spearman's rho coefficients -0.46 and -0.35, respectively). Specifically, from 2007 to 2009 to 2019-2021 CTDIvol and DLP decreased from 2.94 (2.14-2.99) mGy and 309 (230-371) mGy*cm, respectively, to 0.855 (0.568-1.11) mGy and 108 (65.6-207) mGy*cm, respectively. From 2007 to 2021, image noise in the brain and liver remained constant (p = 0.26 and p = 0.06), while it decreased in the adductor muscles (p = 0.007). Peak tube voltage selection (in kilovolt, kV) of CT scans shifted from high kV imaging (140 or 120kVp) to low kV imaging (100 or 80kVp) (p < 0.001) from 2007 to 2021. CONCLUSION: CT radiation dose in pediatric patients undergoing hybrid 2-[18F]FDG PET/CT has decreased in recent years equaling approximately one-third of the initial amount. ADVANCES IN KNOWLEDGE: Over the past 15 years, CT radiation dose decreased considerably in pediatric patients undergoing hybrid imaging, while objective image quality may not have been compromised.


Assuntos
Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Feminino , Humanos , Criança , Adolescente , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Encéfalo
14.
Abdom Radiol (NY) ; 48(8): 2658-2671, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37208547

RESUMO

PURPOSE: To compare multi-slice (MS) MRI sequences of the pelvis acquired at rest and straining to dynamic midsagittal single-slice (SS) sequences for the assessment of pelvic organ prolapse (POP). METHODS: This IRB-approved prospective single-center feasibility study included 23 premenopausal symptomatic patients with POP and 22 asymptomatic nulliparous volunteers. MRI of the pelvis at rest and straining was performed with midsagittal SS and MS sequences. Straining effort, visibility of organs and POP grade were scored on both. Organ points (bladder, cervix, anorectum) were measured. Differences between SS and MS sequences were compared with Wilcoxon test. RESULTS: Straining effort was good in 84.4% on SS and in 64.4% on MS sequences (p = 0.003). Organ points were always visible on MS sequences, whereas the cervix was not fully visible in 31.1-33.3% on SS sequences. At rest, there were no statistically significant differences of organ point measurements between SS and MS sequences in symptomatic patients. At straining, positions of bladder, cervix, and anorectum were + 1.1 cm (± 1.8 cm), - 0.7 cm (± 2.9 cm), and + 0.7 cm (± 1.3 cm) on SS and + 0.4 mm (± 1.7 cm), - 1.4 cm (± 2.6 cm), and + 0.4 cm (± 1.3 cm) on MS sequences (p < 0.05). Only 2 cases of higher-grade POP were missed on MS sequences (both with poor straining effort). CONCLUSION: MS sequences increase the visibility of organ points compared to SS sequences. Dynamic MS sequences can depict POP if images are acquired with sufficient straining effort. Further work is needed to optimize the depiction of the maximum straining effort with MS sequences.


Assuntos
Prolapso de Órgão Pélvico , Humanos , Feminino , Estudos Prospectivos , Estudos de Viabilidade , Prolapso de Órgão Pélvico/diagnóstico por imagem , Pelve , Imageamento por Ressonância Magnética
15.
Sci Rep ; 13(1): 11332, 2023 07 13.
Artigo em Inglês | MEDLINE | ID: mdl-37443158

RESUMO

To evaluate whether a machine learning classifier can evaluate image quality of maximum intensity projection (MIP) images from F18-FDG-PET scans. A total of 400 MIP images from F18-FDG-PET with simulated decreasing acquisition time (120 s, 90 s, 60 s, 30 s and 15 s per bed-position) using block sequential regularized expectation maximization (BSREM) with a beta-value of 450 and 600 were created. A machine learning classifier was fed with 283 images rated "sufficient image quality" and 117 images rated "insufficient image quality". The classification performance of the machine learning classifier was assessed by calculating sensitivity, specificity, and area under the receiver operating characteristics curve (AUC) using reader-based classification as the target. Classification performance of the machine learning classifier was AUC 0.978 for BSREM beta 450 and 0.967 for BSREM beta 600. The algorithm showed a sensitivity of 89% and 94% and a specificity of 94% and 94% for the reconstruction BSREM 450 and 600, respectively. Automated assessment of image quality from F18-FDG-PET images using a machine learning classifier provides equivalent performance to manual assessment by experienced radiologists.


Assuntos
Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Tomografia por Emissão de Pósitrons , Redes Neurais de Computação , Algoritmos , Processamento de Imagem Assistida por Computador/métodos
16.
Sci Rep ; 13(1): 18357, 2023 10 26.
Artigo em Inglês | MEDLINE | ID: mdl-37884535

RESUMO

This study aimed to evaluate the diagnostic accuracy of Node Reporting and Data System (Node-RADS) in discriminating between normal, reactive, and metastatic axillary LNs in patients with melanoma who underwent SARS-CoV-2 vaccination. Patients with proven melanoma who underwent a 2-[18F]-fluoro-2-deoxy-D-glucose positron emission tomography/computed tomography (2-[18F]-FDG PET/CT) between February and April 2021 were included in this retrospective study. Primary melanoma site, vaccination status, injection site, and 2-[18F]-FDG PET/CT were used to classify axillary LNs into normal, inflammatory, and metastatic (combined classification). An adapted Node-RADS classification (A-Node-RADS) was generated based on LN anatomical characteristics on low-dose CT images and compared to the combined classification. 108 patients were included in the study (54 vaccinated). HALNs were detected in 42 patients (32.8%), of whom 97.6% were vaccinated. 172 LNs were classified as normal, 30 as inflammatory, and 14 as metastatic using the combined classification. 152, 22, 29, 12, and 1 LNs were classified A-Node-RADS 1, 2, 3, 4, and 5, respectively. Hence, 174, 29, and 13 LNs were deemed benign, equivocal, and metastatic. The concordance between the classifications was very good (Cohen's k: 0.91, CI 0.86-0.95; p-value < 0.0001). A-Node-RADS can assist the classification of axillary LNs in melanoma patients who underwent 2-[18F]-FDG PET/CT and SARS-CoV-2 vaccination.


Assuntos
COVID-19 , Melanoma , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Vacinas contra COVID-19 , SARS-CoV-2 , Fluordesoxiglucose F18 , Estudos Retrospectivos , Estadiamento de Neoplasias , Metástase Linfática/patologia , COVID-19/diagnóstico por imagem , COVID-19/patologia , Linfonodos/diagnóstico por imagem , Linfonodos/patologia , Melanoma/diagnóstico por imagem , Melanoma/patologia , Vacinação , Compostos Radiofarmacêuticos
17.
Eur J Radiol Open ; 10: 100487, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37065611

RESUMO

Purpose: To compare the accuracy of multiparametric MRI (mpMRI), 68Ga-PSMA PET and the Briganti 2019 nomogram in the prediction of metastatic pelvic lymph nodes (PLN) in prostate cancer, to assess the accuracy of mpMRI and the Briganti nomogram in prediction of PET positive PLN and to investigate the added value of quantitative mpMRI parameters to the Briganti nomogram. Method: This retrospective IRB-approved study included 41 patients with prostate cancer undergoing mpMRI and 68Ga-PSMA PET/CT or MR prior to prostatectomy and pelvic lymph node dissection. A board-certified radiologist assessed the index lesion on diffusion-weighted (Apparent Diffusion Coefficient, ADC; mean/volume), T2-weighted (capsular contact length, lesion volume/maximal diameters) and contrast-enhanced (iAUC, kep, Ktrans, ve) sequences. The probability for metastatic pelvic lymph nodes was calculated using the Briganti 2019 nomogram. PET examinations were evaluated by two board-certified nuclear medicine physicians. Results: The Briganti 2019 nomogram performed superiorly (AUC: 0.89) compared to quantitative mpMRI parameters (AUCs: 0.47-0.73) and 68Ga-PSMA-11 PET (AUC: 0.82) in the prediction of PLN metastases and superiorly (AUC: 0.77) in the prediction of PSMA PET positive PLN compared to MRI parameters (AUCs: 0.49-0.73). The addition of mean ADC and ADC volume from mpMRI improved the Briganti model by a fraction of new information of 0.21. Conclusions: The Briganti 2019 nomogram performed superiorly in the prediction of metastatic and PSMA PET positive PLN, but the addition of parameters from mpMRI can further improve its accuracy. The combined model could be used to stratify patients requiring ePLND or PSMA PET.

18.
Sci Rep ; 13(1): 18847, 2023 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-37914764

RESUMO

The purpose of this retrospective study was to investigate response of sinonasal mucosal melanoma (SMM) patients to treatment with immune checkpoint inhibitors (ICI), using hybrid PET imaging. Fifteen SMM patients underwent hybrid PET imaging before and three months after initiation of ICI. The disease-specific survival (DSS) was calculated. Quantitative PET parameters of the primary tumor and their association with DSS and therapy response were investigated. Nine of the fifteen (60%) patients responded to ICI therapy. Patients with therapy response depicted on hybrid PET imaging had better DSS than those without (p = 0.0058). Quantitative PET parameters of the initial PET harbored no association with DSS or therapy response. However, these findings lack of sufficient statistical power and must be interpreted with caution. The first restaging PET-imaging after ICI initiation can help stratify patients with regard to DSS.


Assuntos
Melanoma , Neoplasias dos Seios Paranasais , Humanos , Inibidores de Checkpoint Imunológico/farmacologia , Inibidores de Checkpoint Imunológico/uso terapêutico , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Estudos Retrospectivos , Melanoma/diagnóstico por imagem , Melanoma/tratamento farmacológico , Melanoma/patologia , Tomografia por Emissão de Pósitrons , Neoplasias dos Seios Paranasais/patologia , Fluordesoxiglucose F18
19.
Clin Nucl Med ; 47(2): 185-186, 2022 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-34507324

RESUMO

ABSTRACT: A 78-year-old man with multiple squamous cell carcinomas of the skin underwent 18F-FDG-PET/CT for restaging after 4 cycles of cemiplimab. The scan showed new disseminated FDG-avid skin lesions. Dermatologic examination and biopsy revealed bullous pemphigoid. Discontinuation of cemiplimab and treatment with corticosteroids led to clinical improvement, after which treatment with cemiplimab was resumed. A broad spectrum of inflammatory adverse events can occur in patients treated with immune checkpoint inhibitors, and FDG avidity of these lesions may mimic metastases. Knowledge of such imaging pitfalls is essential for interpreting 18F-FDG-PET/CT, particularly if they occur in the same organ as the primary tumor.


Assuntos
Anticorpos Monoclonais Humanizados/efeitos adversos , Carcinoma de Células Escamosas , Imunoterapia/efeitos adversos , Penfigoide Bolhoso , Idoso , Anticorpos Monoclonais Humanizados/uso terapêutico , Carcinoma de Células Escamosas/tratamento farmacológico , Fluordesoxiglucose F18 , Humanos , Masculino , Penfigoide Bolhoso/induzido quimicamente , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Compostos Radiofarmacêuticos
20.
Diagn Interv Imaging ; 103(5): 273-280, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-34991993

RESUMO

PURPOSE: The purpose of this study was to assess whether the performances of an automated software for lung nodule detection with computed tomography (CT) are affected by radiation dose and the use of iterative reconstruction algorithm. MATERIALS AND METHODS: A chest phantom (Multipurpose Chest Phantom N1; Kyoto Kagaku Co. Ltd, Kyoto, Japan) with 15 pulmonary nodules was scanned with a total of five CT protocol settings with up to 20-fold dose reduction. All CT examinations were reconstructed with iterative reconstruction algorithms ADMIRE 3 and ADMIRE 5 and were then analyzed for the presence of pulmonary nodules with a fully automated computer aided detection software system (InferReadTM CT Lung, Infervision), which is based on deep neural networks. RESULTS: The sensitivity of fully automated pulmonary nodule detection for ground-glass nodules at standard dose CT was greater (70.0%; 14/20; 95% CI: 51.6-88.4%) than at 10-fold and 20-fold dose reduction (30.0%; 6/20; 95% CI: 0.0%-62.5%). There were less false positive findings when ADMIRE 5 reconstruction was used (4.0 ± 2.8 [SD]; range: 2-6) instead of ADMIRE 3 reconstruction (25.0 ± 15.6 [SD]; range: 14-36). There was no difference in the sensitivity of detection of solid and subsolid nodules between standard dose (100%; 95% CI: 100-100%) and 10- and 20-fold reduced dose CT (92.5%; 95% CI: 83.8-100.0%). Image noise was significantly greater with ADMIRE 3 (81 ± 2 [SD] [range: 79-84]; 104 ± 3 [SD] [range: 101-107]; 114 ± 5 [SD] [range: 110-119]; 193 ± 10 [SD] [range: 183-203]; 220 ± 16 [SD] [range: 210-238]) compared to ADMIRE 5 (44 ± 2 [SD] [range: 42-46]; 60 ± 2 [SD] [range: 57-61]; 66 ± 1 [SD] [range: 65-67]; 103 ± 4 [SD] [range: 98-106]; 110 ± 1 [SD] [range: 109-111]), respectively in each of the five CT protocols. CONCLUSION: This phantom study suggests that dose reduction and iterative reconstruction settings have an impact on detectability of pulmonary nodules by artificial intelligence software and we therefore encourage adaption of dose levels and reconstruction methods prior to widespread implementation of fully automatic nodule detection software for lung cancer screening purposes.


Assuntos
Neoplasias Pulmonares , Nódulos Pulmonares Múltiplos , Algoritmos , Inteligência Artificial , Redução da Medicação , Detecção Precoce de Câncer , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Nódulos Pulmonares Múltiplos/diagnóstico por imagem , Imagens de Fantasmas , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa