1.
N Engl J Med ; 387(13): 1161-1172, 2022 09 29.
Artigo em Inglês | MEDLINE | ID: mdl-36170500

RESUMO

BACKGROUND: Currently available semiautomated insulin-delivery systems require individualized insulin regimens for the initialization of therapy and meal doses based on carbohydrate counting for routine operation. In contrast, the bionic pancreas is initialized only on the basis of body weight, makes all dose decisions and delivers insulin autonomously, and uses meal announcements without carbohydrate counting. METHODS: In this 13-week, multicenter, randomized trial, we randomly assigned in a 2:1 ratio persons at least 6 years of age with type 1 diabetes either to receive bionic pancreas treatment with insulin aspart or insulin lispro or to receive standard care (defined as any insulin-delivery method with unblinded, real-time continuous glucose monitoring). The primary outcome was the glycated hemoglobin level at 13 weeks. The key secondary outcome was the percentage of time that the glucose level as assessed by continuous glucose monitoring was below 54 mg per deciliter; the prespecified noninferiority limit for this outcome was 1 percentage point. Safety was also assessed. RESULTS: A total of 219 participants 6 to 79 years of age were assigned to the bionic-pancreas group, and 107 to the standard-care group. The glycated hemoglobin level decreased from 7.9% to 7.3% in the bionic-pancreas group and did not change (was at 7.7% at both time points) in the standard-care group (mean adjusted difference at 13 weeks, -0.5 percentage points; 95% confidence interval [CI], -0.6 to -0.3; P<0.001). The percentage of time that the glucose level as assessed by continuous glucose monitoring was below 54 mg per deciliter did not differ significantly between the two groups (13-week adjusted difference, 0.0 percentage points; 95% CI, -0.1 to 0.04; P<0.001 for noninferiority). The rate of severe hypoglycemia was 17.7 events per 100 participant-years in the bionic-pancreas group and 10.8 events per 100 participant-years in the standard-care group (P = 0.39). No episodes of diabetic ketoacidosis occurred in either group. CONCLUSIONS: In this 13-week, randomized trial involving adults and children with type 1 diabetes, use of a bionic pancreas was associated with a greater reduction than standard care in the glycated hemoglobin level. (Funded by the National Institute of Diabetes and Digestive and Kidney Diseases and others; ClinicalTrials.gov number, NCT04200313.).


Assuntos
Diabetes Mellitus Tipo 1 , Hipoglicemiantes , Insulina Aspart , Sistemas de Infusão de Insulina , Insulina Lispro , Adolescente , Adulto , Idoso , Biônica/instrumentação , Glicemia/análise , Automonitorização da Glicemia/instrumentação , Automonitorização da Glicemia/métodos , Criança , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hemoglobinas Glicadas/análise , Humanos , Hipoglicemiantes/administração & dosagem , Hipoglicemiantes/efeitos adversos , Hipoglicemiantes/uso terapêutico , Insulina/administração & dosagem , Insulina/efeitos adversos , Insulina/uso terapêutico , Insulina Aspart/administração & dosagem , Insulina Aspart/efeitos adversos , Insulina Aspart/uso terapêutico , Sistemas de Infusão de Insulina/efeitos adversos , Insulina Lispro/administração & dosagem , Insulina Lispro/efeitos adversos , Insulina Lispro/uso terapêutico , Pessoa de Meia-Idade , Adulto Jovem
2.
Pediatr Diabetes ; 22(4): 586-593, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33502062

RESUMO

BACKGROUND: Control-IQ (Tandem Diabetes) is a hybrid closed-loop (HCL) system that users self-initiate after completing online training. Best practices for clinical follow-up are not known. Our quality improvement objective was to evaluate the usefulness of an educator-led follow-up program for new HCL users in a type 1 diabetes pediatric clinic. METHODS: We implemented an ''HCLCheck-in'' program, first determining when users started HCL, then having diabetes educators contact them for a follow-up call 2-weeks after start. Educators used a Clinical Tool to inform insulin dose and behavior recommendations, and used four benchmarks to determine need for further follow-up: ≥71% HCL use, ≥71% CGM use, ≥60% Time-in-Range (TIR, 70-180 mg/dL), <5% below 70 mg/dL. Family and educator satisfaction were surveyed. RESULTS: One-hundred-twenty-three youth [mean age 13.6 ± 3.7 y, 53.7% female, mean HbA1c 7.6 ± 1.4% (60 mmol/mol)] completed an HCLCheck-in call a median (IQR) of 18(15, 21) days post-HCL start. 74 users (60%) surpassed benchmarks with 94% HCL use and 71% TIR. Of the 49 who did not, 16 completed a second call, and improved median TIR 12.5% (p = 0.03). HCL users reported high satisfaction with the program overall [median 10 (9, 10) out of 10]. Educators spent a median of 45 (32,70) minutes per user and rated satisfaction with the program as 8 (7,9.5) and the Tool as 9 (9, 10). CONCLUSION: Our HCLCheck-in program received high satisfaction ratings and resulted in improved TIR for those initially not meeting benchmarks, suggesting users may benefit from early follow-up. Similar programs may be beneficial for other new technologies.


Assuntos
Automonitorização da Glicemia , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/tratamento farmacológico , Sistemas de Infusão de Insulina , Adolescente , Glicemia/metabolismo , Criança , Feminino , Seguimentos , Hemoglobinas Glicadas/metabolismo , Humanos , Hipoglicemiantes/administração & dosagem , Insulina/administração & dosagem , Masculino , Educação de Pacientes como Assunto , Satisfação do Paciente , Avaliação de Programas e Projetos de Saúde , Melhoria de Qualidade
3.
Pediatr Diabetes ; 18(7): 547-552, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27726268

RESUMO

OBJECTIVE: Pediatric patients in Colorado with new onset type 1 diabetes (T1D) presenting with diabetic ketoacidosis (DKA) increased from 29.9% to 46.2% from 1998 to 2012. The purpose of this study was to compare differences between patients with newly diagnosed T1D who presented in DKA with those who did not across three domains: sociodemographic factors, access to medical care, and medical provider factors, aiming to identify potential targets for intervention. METHODS: Sixty-one patients <17 years of age with T1D duration <6 months completed the questionnaire. Groups were compared using Fisher's exact test or the Kruskal-Wallis test. RESULTS: Parents of 28% of patients researched their child's symptoms on the Internet prior to diagnosis. At the first healthcare visit for symptoms of T1D, 23% were not diagnosed. There were no significant differences between groups (DKA vs non-DKA) in demographics, first healthcare setting for T1D symptoms, provider type at first visit or at diagnosis, insurance status, or specific barriers to care. DKA patients had a longer interval between previous well visit to diagnosis (median 172 vs 263 days, P = 0.01). Non-DKA patients were more likely to have blood glucose measured at P = 0.02, and had fewer symptoms prior to (P = 0.01) the first visit for diabetes symptoms. Parents of non-DKA patients were more likely to be familiar with symptoms of diabetes (P < 0.001) and to suspect diabetes (P = 0.01). CONCLUSION: Targets for campaigns to prevent DKA include increasing provider glucose and ketone testing, increasing public knowledge about diabetes, and understanding how socio-demographic factors may delay T1D diagnosis.


Assuntos
Diabetes Mellitus Tipo 1/diagnóstico , Cetoacidose Diabética/terapia , Aceitação pelo Paciente de Cuidados de Saúde , Centros Médicos Acadêmicos , Acesso à Informação , Adolescente , Glicemia/análise , Criança , Pré-Escolar , Colorado , Informação de Saúde ao Consumidor , Diagnóstico Tardio , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/prevenção & controle , Diabetes Mellitus Tipo 1/urina , Pesquisas sobre Atenção à Saúde , Acessibilidade aos Serviços de Saúde , Humanos , Lactente , Internet , Corpos Cetônicos/urina , Masculino , Avaliação das Necessidades , Ambulatório Hospitalar , Pais , Projetos Piloto , Estudos Retrospectivos , Fatores Socioeconômicos
4.
N Engl J Med ; 369(3): 224-32, 2013 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-23789889

RESUMO

BACKGROUND: The threshold-suspend feature of sensor-augmented insulin pumps is designed to minimize the risk of hypoglycemia by interrupting insulin delivery at a preset sensor glucose value. We evaluated sensor-augmented insulin-pump therapy with and without the threshold-suspend feature in patients with nocturnal hypoglycemia. METHODS: We randomly assigned patients with type 1 diabetes and documented nocturnal hypoglycemia to receive sensor-augmented insulin-pump therapy with or without the threshold-suspend feature for 3 months. The primary safety outcome was the change in the glycated hemoglobin level. The primary efficacy outcome was the area under the curve (AUC) for nocturnal hypoglycemic events. Two-hour threshold-suspend events were analyzed with respect to subsequent sensor glucose values. RESULTS: A total of 247 patients were randomly assigned to receive sensor-augmented insulin-pump therapy with the threshold-suspend feature (threshold-suspend group, 121 patients) or standard sensor-augmented insulin-pump therapy (control group, 126 patients). The changes in glycated hemoglobin values were similar in the two groups. The mean AUC for nocturnal hypoglycemic events was 37.5% lower in the threshold-suspend group than in the control group (980 ± 1200 mg per deciliter [54.4 ± 66.6 mmol per liter] × minutes vs. 1568 ± 1995 mg per deciliter [87.0 ± 110.7 mmol per liter] × minutes, P<0.001). Nocturnal hypoglycemic events occurred 31.8% less frequently in the threshold-suspend group than in the control group (1.5 ± 1.0 vs. 2.2 ± 1.3 per patient-week, P<0.001). The percentages of nocturnal sensor glucose values of less than 50 mg per deciliter (2.8 mmol per liter), 50 to less than 60 mg per deciliter (3.3 mmol per liter), and 60 to less than 70 mg per deciliter (3.9 mmol per liter) were significantly reduced in the threshold-suspend group (P<0.001 for each range). After 1438 instances at night in which the pump was stopped for 2 hours, the mean sensor glucose value was 92.6 ± 40.7 mg per deciliter (5.1 ± 2.3 mmol per liter). Four patients (all in the control group) had a severe hypoglycemic event; no patients had diabetic ketoacidosis. CONCLUSIONS: This study showed that over a 3-month period the use of sensor-augmented insulin-pump therapy with the threshold-suspend feature reduced nocturnal hypoglycemia, without increasing glycated hemoglobin values. (Funded by Medtronic MiniMed; ASPIRE ClinicalTrials.gov number, NCT01497938.).


Assuntos
Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemia/prevenção & controle , Hipoglicemiantes/administração & dosagem , Sistemas de Infusão de Insulina , Insulina/administração & dosagem , Adolescente , Adulto , Idoso , Área Sob a Curva , Glicemia/análise , Diabetes Mellitus Tipo 1/sangue , Feminino , Hemoglobinas Glicadas/metabolismo , Humanos , Hipoglicemia/induzido quimicamente , Hipoglicemiantes/efeitos adversos , Insulina/efeitos adversos , Sistemas de Infusão de Insulina/efeitos adversos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
5.
Pediatr Diabetes ; 17(4): 237-43, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-25720763

RESUMO

OBJECTIVE: Prior studies examining beta-cell preservation in type 1 diabetes have predominantly assessed stimulated C-peptide concentrations approximately 10 wk after diagnosis. We examined whether earlier assessments might aid in prediction of beta cell function over time. METHODS: Using data from a multi-center randomized trial assessing the effect of intensive diabetes management initiated within 1 wk of diagnosis, we assessed which clinical factors predicted 90-min mixed-meal tolerance test (MMTT) stimulated C-peptide values obtained 2 and 6 wk after diagnosis. We also studied associations of these factors with C-peptide values at 1- and 2-year post-diagnosis. Data from intervention and control groups were pooled. RESULTS: Among 67 study participants (mean age 13.3 ± 5.7 yr, range 7.8-45.7 yr) in multivariable analyses, C-peptide increased from baseline to 2 wks and then 6 wk. C-peptide levels at these times were significantly correlated with 1- and 2-yr C-peptide concentrations (all p < 0.001), with the strongest observed associations between 6-wk C-peptide and the 1- and 2-yr values (r = 0.66 and r = 0.61, respectively). In multivariable analyses, greater baseline and 6-wk C-peptide, and older age independently predicted greater 1- and 2-yr C-peptide concentrations. CONCLUSIONS: C-peptide assessments close to diagnosis were predictive of subsequent C-peptide production. Our data demonstrate a clear increase in C-peptide over the initial 6 wk after diabetes diagnosis followed by a plateau. Our data do not suggest that MMTT assessments performed closer to diagnosis than 6 wk would improve prediction of subsequent residual beta cell function.


Assuntos
Peptídeo C/sangue , Diabetes Mellitus Tipo 1/sangue , Células Secretoras de Insulina/fisiologia , Adolescente , Adulto , Criança , Diabetes Mellitus Tipo 1/fisiopatologia , Humanos , Pessoa de Meia-Idade , Adulto Jovem
6.
Diabetologia ; 58(6): 1167-74, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25773405

RESUMO

AIMS/HYPOTHESIS: The aim of this work was to assess the association between continuous glucose monitoring (CGM) data, HbA1c, insulin-dose-adjusted HbA1c (IDAA1c) and C-peptide responses during the first 2 years following diagnosis of type 1 diabetes. METHODS: A secondary analysis was conducted of data collected from a randomised trial assessing the effect of intensive management initiated within 1 week of diagnosis of type 1 diabetes, in which mixed-meal tolerance tests were performed at baseline and at eight additional time points through 24 months. CGM data were collected at each visit. RESULTS: Among 67 study participants (mean age [± SD] 13.3 ± 5.7 years), HbA1c was inversely correlated with C-peptide at each time point (p < 0.001), as were changes in each measure between time points (p < 0.001). However, C-peptide at one visit did not predict the change in HbA1c at the next visit and vice versa. Higher C-peptide levels correlated with increased proportion of CGM glucose values between 3.9 and 7.8 mmol/l and lower CV (p = 0.001 and p = 0.02, respectively) but not with CGM glucose levels <3.9 mmol/l. Virtually all participants with IDAA1c < 9 retained substantial insulin secretion but when evaluated together with CGM, time in the range of 3.9-7.8 mmol/l and CV did not provide additional value in predicting C-peptide levels. CONCLUSIONS/INTERPRETATION: In the first 2 years after diagnosis of type 1 diabetes, higher C-peptide levels are associated with increased sensor glucose levels in the target range and with lower glucose variability but not hypoglycaemia. CGM metrics do not provide added value over the IDAA1c in predicting C-peptide levels.


Assuntos
Glicemia/análise , Peptídeo C/sangue , Diabetes Mellitus Tipo 1/sangue , Hemoglobinas Glicadas/metabolismo , Insulina/administração & dosagem , Adolescente , Adulto , Automonitorização da Glicemia , Criança , Teste de Tolerância a Glucose , Humanos , Sistemas de Infusão de Insulina , Pessoa de Meia-Idade , Valores de Referência , Adulto Jovem
8.
Diabetes Technol Ther ; 25(9): 652-658, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37252734

RESUMO

Background: Safety and significant improvement in overall glycated hemoglobin (A1C) and percentage of time spent in (TIR), below (TBR), and above (TAR) glucose range were demonstrated in the pivotal trial of adolescents and adults using the MiniMed™ advanced hybrid closed-loop (AHCL) system with the adjunctive, calibration-required Guardian™ Sensor 3. The present study evaluated early outcomes of continued access study (CAS) participants who transitioned from the pivotal trial investigational system to the approved MiniMed™ 780G system with the non-adjunctive, calibration-free Guardian™ 4 Sensor (MM780G+G4S). Study data were presented alongside those of real-world MM780G+G4S users from Europe, the Middle East, and Africa. Methods: The CAS participants (N = 109, aged 7-17 years and N = 67, aged >17 years) used the MM780G+G4S for 3 months and data of real-world MM780G+G4S system users (N = 10,204 aged ≤15 years and N = 26,099 aged >15 years) were uploaded from September 22, 2021 to December 02, 2022. At least 10 days of real-world continuous glucose monitoring (CGM) data were required for analyses. Glycemic metrics, delivered insulin and system use/interactions underwent descriptive analyses. Results: Time in AHCL and CGM use were >90% for all groups. AHCL exits averaged 0.1/day and there were few blood glucose measurements (BGMs) (0.8/day-1.0/day). Adults in both cohorts met most consensus recommendations for glycemic targets. Pediatric groups met recommendations for %TIR and %TBR, although not those for mean glucose variability and %TAR, possibly due to low use of recommended glucose target (100 mg/dL) and active insulin time (2 h) settings (28.4% in the CAS cohort and 9.4% in the real-world cohort). The CAS pediatric and adult A1C were 7.2% ± 0.7% and 6.8% ± 0.7%, respectively, and there were no serious adverse events. Conclusions: Early clinical use of the MM780G+G4S was safe and involved minimal BGMs and AHCL exits. Consistent with real-world pediatric and adult use, outcomes were associated with achievement of recommended glycemic targets. Clinical Trial Registration number: NCT03959423.


Assuntos
Glicemia , Diabetes Mellitus Tipo 1 , Adolescente , Adulto , Criança , Humanos , Automonitorização da Glicemia , Diabetes Mellitus Tipo 1/tratamento farmacológico , Glucose , Hemoglobinas Glicadas , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Sistemas de Infusão de Insulina
9.
Diabetes Technol Ther ; 25(1): 1-12, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36472543

RESUMO

Objective: To evaluate safety and effectiveness of MiniMed™ 670G hybrid closed loop (HCL) in comparison with continuous subcutaneous insulin infusion (CSII) therapy for 6 months in persons with type 1 diabetes (T1D). Methods: Adults (aged 18-80 years), adolescents, and children (aged 2-17 years) with T1D who were using CSII therapy were enrolled and randomized (1:1) to 6 months of HCL intervention (n = 151, mean age of 39.9 ± 19.8 years) or CSII without continuous glucose monitoring (n = 151, 35.7 ± 18.4 years). Primary effectiveness endpoints included change in A1C for Group 1 (baseline A1C >8.0%), from baseline to the end of study, and difference in the end of study percentage of time spent below 70 mg/dL (%TBR <70 mg/dL) for Group 2 (baseline A1C ≤8.0%), to show superiority of HCL intervention versus control. Secondary effectiveness endpoints were change in A1C and %TBR <70 mg/dL for Group 2 and Group 1, respectively, to show noninferiority of HCL intervention versus control. Primary safety endpoints were rates of severe hypoglycemia and diabetic ketoacidosis (DKA). Results: Change in A1C and difference in %TBR <70 mg/dL for the overall group were significantly improved, in favor of HCL intervention. In addition, a significant mean (95% confidence interval) change in A1C was observed for both Group 1 (-0.8% [-1.1% to -0.4%], P < 0.0001) and Group 2 (-0.3% [-0.5% to -0.1%], P < 0.0001), in favor of HCL intervention. The same was observed for difference in %TBR <70 mg/dL for Group 1 (-2.2% [-3.6% to -0.9%]) and Group 2 (-4.9% [-6.3% to -3.6%]) (P < 0.0001 for both). There was one DKA event during run-in and six severe hypoglycemic events: two during run-in and four during study (HCL: n = 0 and CSII: n = 4 [6.08 per 100 patient-years]). Conclusions: This RCT demonstrates that the MiniMed 670G HCL safely and significantly improved A1C and %TBR <70 mg/dL compared with CSII control in persons with T1D, irrespective of baseline A1C level.


Assuntos
Diabetes Mellitus Tipo 1 , Cetoacidose Diabética , Adolescente , Adulto , Criança , Humanos , Pessoa de Meia-Idade , Adulto Jovem , Glicemia , Automonitorização da Glicemia , Diabetes Mellitus Tipo 1/tratamento farmacológico , Cetoacidose Diabética/tratamento farmacológico , Hemoglobinas Glicadas , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Sistemas de Infusão de Insulina , Pré-Escolar , Idoso , Idoso de 80 Anos ou mais
10.
Diabetes Technol Ther ; 25(11): 755-764, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37782145

RESUMO

Background: During MiniMed™ advanced hybrid closed-loop (AHCL) use by adolescents and adults in the pivotal trial, glycated hemoglobin (A1C) was significantly reduced, time spent in range (TIR) was significantly increased, and there were no episodes of severe hypoglycemia or diabetic ketoacidosis (DKA). The present study investigated the same primary safety and effectiveness endpoints during AHCL use by a younger cohort with type 1 diabetes (T1D). Methods: An intention-to-treat population (N = 160, aged 7-17 years) with T1D was enrolled in a single-arm study at 13 investigational centers. There was a run-in period (∼25 days) using HCL or sensor-augmented pump with/without predictive low-glucose management, followed by a 3-month study period with AHCL activated at two glucose targets (GTs; 100 and 120 mg/dL) for ∼45 days each. The mean ± standard deviation values of A1C, TIR, mean sensor glucose (SG), coefficient of variation (CV) of SG, time at SG ranges, and insulin delivered between run-in and study were analyzed (Wilcoxon signed-rank test or t-test). Results: Compared with baseline, AHCL use was associated with reduced A1C from 7.9 ± 0.9% (N = 160) to 7.4 ± 0.7% (N = 136) (P < 0.001) and overall TIR increased from the run-in 59.4 ± 11.8% to 70.3 ± 6.5% by end of study (P < 0.001), without change in CV, time spent below range (TBR) <70 mg/dL, or TBR <54 mg/dL. Relative to longer active insulin time (AIT) settings (N = 52), an AIT of 2 h (N = 19) with the 100 mg/dL GT increased mean TIR to 73.4%, reduced TBR <70 mg/dL from 3.5% to 2.2%, and reduced time spent above range (TAR) >180 mg/dL from 28.7% to 24.4%. During AHCL use, there was no severe hypoglycemia or DKA. Conclusions: In children and adolescents with T1D, MiniMed AHCL system use was safe, A1C was lower, and TIR was increased. The lowest GT and shortest AIT were associated with the highest TIR and lowest TBR and TAR, all of which met consensus-recommended glycemic targets. ClinicalTrials.gov ID: NCT03959423.


Assuntos
Diabetes Mellitus Tipo 1 , Cetoacidose Diabética , Hipoglicemia , Adolescente , Adulto , Criança , Humanos , Glicemia , Automonitorização da Glicemia , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 1/complicações , Cetoacidose Diabética/etiologia , Glucose , Hemoglobinas Glicadas , Hipoglicemia/induzido quimicamente , Hipoglicemia/prevenção & controle , Hipoglicemia/complicações , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Sistemas de Infusão de Insulina , Resultado do Tratamento
11.
Curr Diab Rep ; 12(5): 510-6, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22791108

RESUMO

Continuing glucose monitoring (CGM) is a relatively new and rapidly developing technology that shows promise for the future management of type 1 diabetes. When used with near-daily frequency, it has a significant effect on improvement of glucose metabolism as measured by HbA1C and reduction of hypoglycemia. It appears to be safe and actually reduces both DKA and severe hypoglycemia. Early studies indicate that it should be cost effective.


Assuntos
Automonitorização da Glicemia/métodos , Adolescente , Automonitorização da Glicemia/economia , Criança , Diabetes Mellitus Tipo 1/sangue , Feminino , Hemoglobinas Glicadas/metabolismo , Humanos , Hipoglicemia/sangue , Masculino
12.
Pediatr Diabetes ; 13(1): 6-11, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21722284

RESUMO

OBJECTIVE: Maintenance of appropriate A1C values and minimization of hyperglycemic excursions are difficult for many pediatric patients with type 1 diabetes. Continuous glucose monitoring (CGM) sensor-augmented pump (SAP) therapy is an alternative to multiple daily injection (MDI) therapy in this population. RESEARCH DESIGN AND METHODS: Sensor-augmented pump therapy for A1C reduction (STAR 3) was a 1-yr trial that included 82 children (aged 7-12) and 74 adolescents (aged 13-18) with A1C values ranging from 7.4 to 9.5% who were randomized to either SAP or MDI therapy. Quarterly A1C values were obtained from all subjects. CGM studies were carried out at baseline, 6 months, and 12 months to quantify glycemic excursions [calculated as area under the glucose concentration-time curve (AUC)] and variability. In the SAP group, sensor compliance was recorded. RESULTS: Baseline A1C values were similar in subjects randomized to the SAP (8.26 ± 0.55%) and MDI groups (8.30 ± 0.53%). All subsequent A1C values showed significant (p < 0.05) treatment group differences favoring SAP therapy. Compared with the MDI group, subjects in the SAP group were more likely to meet age-specific A1C targets and had lower AUC values for hyperglycemia with no increased risk of hypoglycemia. Glucose variability improved in the SAP group compared to the MDI group. Children wore CGM sensors more often and were more likely to reach age-specific A1C targets than adolescents. CONCLUSIONS: SAP therapy allows both children and adolescents with marginally or inadequately controlled type 1 diabetes to reduce A1C values, hyperglycemic excursions, and glycemic variability in a rapid, sustainable, and safe manner.


Assuntos
Técnicas Biossensoriais , Diabetes Mellitus Tipo 1/tratamento farmacológico , Sistemas de Infusão de Insulina , Adolescente , Técnicas Biossensoriais/instrumentação , Técnicas Biossensoriais/estatística & dados numéricos , Automonitorização da Glicemia/instrumentação , Automonitorização da Glicemia/métodos , Criança , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/metabolismo , Relação Dose-Resposta a Droga , Esquema de Medicação , Feminino , Hemoglobinas Glicadas/análise , Humanos , Hipoglicemiantes/administração & dosagem , Insulina/administração & dosagem , Masculino , Resultado do Tratamento , Regulação para Cima
13.
Diabetes Technol Ther ; 24(1): 67-74, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34524007

RESUMO

Background: Clinic-to-clinic telemedicine can increase visit frequency in pediatric patients with type 1 diabetes (T1D) living far from a diabetes specialty clinic, but the impact on adoption of diabetes technology is unclear. Materials and Methods: Pediatric patients with T1D in Colorado and surrounding states who received diabetes care using clinic-to-clinic telemedicine were enrolled. Medical records and surveys were reviewed to ascertain technology use, and data were compared to patients from the main clinic population. Results: Patients (N = 128, baseline mean age 12.4 ± 4.2 years, median T1D duration 3.3 years [IQR 1.4-7.7], mean A1c 8.9% ± 1.8%, 60% male, 75% non-Hispanic white, 77% private insurance) who utilized telemedicine were included. Technology use among telemedicine patients was not associated with gender, T1D duration, insurance, distance from the main clinic or rural designation but was associated with ethnicity and A1c. Compared to the main clinic cohort (N = 3636), continuous glucose monitor (CGM) use and pump/CGM combination use was lower among patients participating in clinic-to-clinic telemedicine (CGM: 29.7% vs. 56.0%, P < 0.001; CGM/pump combination: 27.3% vs. 40.3%, P = 0.004). Technology use was associated with lower A1c regardless of cohort. Conclusions: Compared to patients attending in-person clinic, pediatric T1D patients who use clinic-to-clinic telemedicine due to their distance from the main clinic, have lower CGM and combination CGM/pump use. For both telemedicine and main clinic patients, CGM and CGM/pump combination was associated with lower A1c. Additional research is needed to explore reasons for this discrepancy and find methods to improve CGM use in this population.


Assuntos
Diabetes Mellitus Tipo 1 , Telemedicina , Adolescente , Glicemia , Automonitorização da Glicemia/métodos , Criança , Diabetes Mellitus Tipo 1/terapia , Feminino , Hemoglobinas Glicadas/análise , Humanos , Hipoglicemiantes , Masculino , Tecnologia
14.
Diabetes Technol Ther ; 24(3): 178-189, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34694909

RESUMO

Introduction: This trial assessed safety and effectiveness of an advanced hybrid closed-loop (AHCL) system with automated basal (Auto Basal) and automated bolus correction (Auto Correction) in adolescents and adults with type 1 diabetes (T1D). Materials and Methods: This multicenter single-arm study involved an intent-to-treat population of 157 individuals (39 adolescents aged 14-21 years and 118 adults aged ≥22-75 years) with T1D. Study participants used the MiniMed™ AHCL system during a baseline run-in period in which sensor-augmented pump +/- predictive low glucose management or Auto Basal was enabled for ∼14 days. Thereafter, Auto Basal and Auto Correction were enabled for a study phase (∼90 days), with glucose target set to 100 or 120 mg/dL for ∼45 days, followed by the other target for ∼45 days. Study endpoints included safety events and change in mean A1C, time in range (TIR, 70-180 mg/dL) and time below range (TBR, <70 mg/dL). Run-in and study phase values were compared using Wilcoxon signed-rank test or paired t-test. Results: Overall group time spent in closed loop averaged 94.9% ± 5.4% and involved only 1.2 ± 0.8 exits per week. Compared with run-in, AHCL reduced A1C from 7.5% ± 0.8% to 7.0% ± 0.5% (<0.001, Wilcoxon signed-rank test, n = 155), TIR increased from 68.8% ± 10.5% to 74.5% ± 6.9% (<0.001, Wilcoxon signed-rank test), and TBR reduced from 3.3% ± 2.9% to 2.3% ± 1.7% (<0.001, Wilcoxon signed-rank test). Similar benefits to glycemia were observed for each age group and were more pronounced for the nighttime (12 AM-6 AM). The 100 mg/dL target increased TIR to 75.4% (n = 155), which was further optimized at a lower active insulin time (AIT) setting (i.e., 2 h), without increasing TBR. There were no severe hypoglycemic or diabetic ketoacidosis events during the study phase. Conclusions: These findings show that the MiniMed AHCL system is safe and allows for achievement of recommended glycemic targets in adolescents and adults with T1D. Adjustments in target and AIT settings may further optimize glycemia and improve user experience. Clinical Trial Registration number: NCT03959423.


Assuntos
Diabetes Mellitus Tipo 1 , Adolescente , Adulto , Idoso , Glicemia , Automonitorização da Glicemia , Diabetes Mellitus Tipo 1/tratamento farmacológico , Humanos , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Sistemas de Infusão de Insulina , Pessoa de Meia-Idade , Adulto Jovem
15.
Diabetes Care ; 45(8): 1907-1910, 2022 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-35678724

RESUMO

OBJECTIVE: Very young children with type 1 diabetes often struggle to achieve glycemic targets, putting them at risk for long-term complications and creating an immense management burden for caregivers. We conducted the first evaluation of the Omnipod 5 Automated Insulin Delivery System in this population. RESEARCH DESIGN AND METHODS: A total of 80 children aged 2.0-5.9 years used the investigational system in a single-arm study for 13 weeks following 14 days of baseline data collection with their usual therapy. RESULTS: There were no episodes of severe hypoglycemia or diabetic ketoacidosis. By study end, HbA1c decreased by 0.55% (6.0 mmol/mol) (P < 0.0001). Time with sensor glucose levels in target range 70-180 mg/dL increased by 10.9%, or 2.6 h/day (P < 0.0001), while time with levels <70 mg/dL declined by median 0.27% (P = 0.0204). CONCLUSIONS: Use of the automated insulin delivery system was safe, and participants experienced improved glycemic measures and reduced hypoglycemia during the study phase compared with baseline.


Assuntos
Diabetes Mellitus Tipo 1 , Hipoglicemia , Glicemia , Criança , Pré-Escolar , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 1/epidemiologia , Hemoglobinas Glicadas/análise , Humanos , Hipoglicemia/epidemiologia , Hipoglicemiantes/efeitos adversos , Insulina/efeitos adversos , Sistemas de Infusão de Insulina , Insulina Regular Humana/uso terapêutico
16.
Diabetes Technol Ther ; 23(6): 410-424, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33325779

RESUMO

Background: The objective of this study was to assess the safety and effectiveness of the first commercial configuration of a tubeless automated insulin delivery system, Omnipod® 5, in children (6-13.9 years) and adults (14-70 years) with type 1 diabetes (T1D) in an outpatient setting. Materials and Methods: This was a single-arm, multicenter, prospective clinical study. Data were collected over a 14-day standard therapy (ST) phase followed by a 14-day hybrid closed-loop (HCL) phase, where participants (n = 36) spent 72 h at each of three prespecified glucose targets (130, 140, and 150 mg/dL, 9 days total) then 5 days with free choice of glucose targets (110-150 mg/dL) using the Omnipod 5. Remote safety monitoring alerts were enabled during the HCL phase. Primary endpoints were difference in time in range (TIR) (70-180 mg/dL) between ST and HCL phases and proportion of participants reporting serious device-related adverse events. Results: Mean TIR was significantly higher among children in the free-choice period overall (64.9% ± 12.2%, P < 0.01) and when using a 110 mg/dL target (71.2% ± 10.2%, P < 0.01), a 130 mg/dL target (61.5% ± 7.7%, P < 0.01), and a 140 mg/dL target (64.8% ± 11.6%, P < 0.01), and among adults using a 130 mg/dL target (75.1% ± 11.6%, P < 0.05), compared to the ST phase (children: 51.0% ± 13.3% and adults: 65.6% ± 15.7%). There were no serious device-related adverse events reported during the HCL phase, nor were there episodes of severe hypoglycemia or diabetic ketoacidosis. Conclusion: The Omnipod 5 System was safe and effective when used at glucose targets from 110 to 150 mg/dL for 14 days at home in children and adults with T1D.


Assuntos
Diabetes Mellitus Tipo 1 , Adulto , Glicemia , Criança , Diabetes Mellitus Tipo 1/tratamento farmacológico , Glucose , Humanos , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Sistemas de Infusão de Insulina , Pacientes Ambulatoriais , Estudos Prospectivos
18.
Nat Med ; 26(9): 1380-1384, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32908282

RESUMO

Despite the increasing adoption of insulin pumps and continuous glucose monitoring devices, most people with type 1 diabetes do not achieve their glycemic goals1. This could be related to a lack of expertise or inadequate time for clinicians to analyze complex sensor-augmented pump data. We tested whether frequent insulin dose adjustments guided by an automated artificial intelligence-based decision support system (AI-DSS) is as effective and safe as those guided by physicians in controlling glucose levels. ADVICE4U was a six-month, multicenter, multinational, parallel, randomized controlled, non-inferiority trial in 108 participants with type 1 diabetes, aged 10-21 years and using insulin pump therapy (ClinicalTrials.gov no. NCT03003806). Participants were randomized 1:1 to receive remote insulin dose adjustment every three weeks guided by either an AI-DSS, (AI-DSS arm, n = 54) or by physicians (physician arm, n = 54). The results for the primary efficacy measure-the percentage of time spent within the target glucose range (70-180 mg dl-1 (3.9-10.0 mmol l-1))-in the AI-DSS arm were statistically non-inferior to those in the physician arm (50.2 ± 11.1% versus 51.6 ± 11.3%, respectively, P < 1 × 10-7). The percentage of readings below 54 mg dl-1 (<3.0 mmol l-1) within the AI-DSS arm was statistically non-inferior to that in the physician arm (1.3 ± 1.4% versus 1.0 ± 0.9%, respectively, P < 0.0001). Three severe adverse events related to diabetes (two severe hypoglycemia, one diabetic ketoacidosis) were reported in the physician arm and none in the AI-DSS arm. In conclusion, use of an automated decision support tool for optimizing insulin pump settings was non-inferior to intensive insulin titration provided by physicians from specialized academic diabetes centers.


Assuntos
Automonitorização da Glicemia/instrumentação , Automonitorização da Glicemia/métodos , Glicemia/análise , Sistemas de Apoio a Decisões Clínicas/instrumentação , Diabetes Mellitus Tipo 1/tratamento farmacológico , Insulina/uso terapêutico , Adolescente , Inteligência Artificial , Criança , Humanos , Insulina/administração & dosagem , Sistemas de Infusão de Insulina , Resultado do Tratamento , Adulto Jovem
19.
J Diabetes Sci Technol ; 14(2): 290-296, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-30862242

RESUMO

BACKGROUND: Hybrid closed loop (HCL) therapy is now available in clinical practice for treatment of type 1 diabetes; however, there is limited research on how to educate patients on this new therapy. The purpose of this quality improvement project was to optimize a HCL education program for pediatric patients with type 1 diabetes (T1D). METHODS: Our multidisciplinary team developed a novel HCL clinical training program for current insulin pump users, using a quality improvement process called the Plan-Do-Study-Act model. Seventy-two patients participated in the HCL training program, which included (1) an in-person group class to reinforce conventional insulin pump and CGM use on the new system, (2) a live video conference class to teach HCL use, and (3) three follow-up phone calls in the first 4 weeks after HCL training to assess system use, make insulin adjustments, and provide targeted reeducation. Diabetes educators collected data during follow-up calls, and patients completed a training satisfaction survey. RESULTS: The quality improvement process resulted in a training program that emphasized education on HCL exits, CGM use, and optimizing insulin to carbohydrate ratio settings. Patients successfully sustained time in HCL in the initial weeks of use and rated the trainings and follow-up calls highly. CONCLUSIONS: Ongoing educational support is vital in the early weeks of HCL use. This quality improvement project is the first to examine strategies for implementation of HCL therapy into a large pediatric diabetes center, and may inform best practices for implementation of new diabetes technologies into other diabetes clinics.


Assuntos
Glicemia/análise , Controle Glicêmico/instrumentação , Sistemas de Infusão de Insulina , Insulina/administração & dosagem , Educação de Pacientes como Assunto/organização & administração , Adolescente , Instituições de Assistência Ambulatorial/organização & administração , Automonitorização da Glicemia/instrumentação , Criança , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/tratamento farmacológico , Feminino , Seguimentos , Humanos , Comunicação Interdisciplinar , Masculino , Equipe de Assistência ao Paciente/organização & administração , Educação de Pacientes como Assunto/métodos , Avaliação de Programas e Projetos de Saúde , Melhoria de Qualidade , Inquéritos e Questionários
20.
Perm J ; 22: 17-147, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30005730

RESUMO

CONTEXT: Our pediatric diabetes center initiated insulin pump therapy for more than 250 patients with type 1 diabetes in 2014, but onboarding was inefficient. OBJECTIVE: To decrease time from the decision to initiate pump therapy to the ambulatory encounter after pump start (lead time) for new pump users from 132.5 days to less than 110 days within 5 months. DESIGN: Define, Measure, Analyze, Improve, Control method. We identified key problems: Long wait for training classes, unclear metrics, complicated scheduling, and nonstandardized processes. We then implemented 17 changes, including shortened classes, increased class offerings and space, clarified metrics, built a reporting dashboard, designated and cross-trained staff, created appeals letter templates, and educated clinicians. At project conclusion, we established a reaction plan if the processes were not performing as designed. MAIN OUTCOME MEASURES: Outcomes of pump orders placed before and after improvements were implemented. RESULTS: During this project, 229 patients initiated the pump start process. Median lead time decreased from 132.5 to 98.5 days (p = 0.007). Patients with lead time under 110 days increased from 37% to 60% (p = 0.001). There were 31 pump nonstarters, with no significant association between group and whether the patient was a starter or nonstarter (p = 0.58). Nonstarters had a longer diabetes duration (median = 3.43 vs 2.05 years, p = 0.001). CONCLUSION: Project goals were met. A high proportion of patients not starting pump therapy was discovered, but this was not affected by the project. We implemented further changes and a process-monitoring system.


Assuntos
Diabetes Mellitus Tipo 1/tratamento farmacológico , Sistemas de Infusão de Insulina , Melhoria de Qualidade , Criança , Humanos , Fatores de Tempo