Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 44
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Europace ; 25(11)2023 11 02.
Artigo em Inglês | MEDLINE | ID: mdl-37936325

RESUMO

AIMS: Transvenous lead extraction (TLE) is important in the management of cardiac implantable electronic devices but carries risk. It is most commonly completed from the superior access, often with 'bail-out' support via the femoral approach. Superior and inferior access may be used in tandem, which has been proposed as an advance in safety and efficacy. The aim of this study is to evaluate the safety and efficacy of the Tandem approach. METHOD: The 'Tandem' procedure entailed grasping of the targeted lead in the right atrium to provide countertraction as a rotational dissecting sheath was advanced over the lead from the subclavian access. Consecutive 'Tandem' procedures performed by a single operator between December 2020 and March 2023 in a single large-volume TLE centre were included and compared with the conventional superior approach (control) using 1:1 propensity score matching; patients were statistically matched for demographics. RESULTS: The Tandem in comparison with the conventional approach extracted leads of much greater dwell time (148.9 ± 79 vs. 108.6 ± 77 months, P < 0.01) in a shorter procedure duration (96 ± 36 vs. 127 ± 67 min, P < 0.01) but requiring more fluoroscopy (16.4 ± 10.9 vs. 10.8 ± 14.9 min, P < 0.01). The Tandem and control groups had similar clinical (100% vs. 94.7%, P = 0.07) and complete (94.8% vs. 92.8%, P = 0.42) success, with comparable minor (4% vs. 6.7%, P = 0.72) and major (0% vs. 4%, P = 0.25) complications; procedural (0% vs. 1.3%, P = 1) and 30-day (1.3% vs. 4%, P = 0.62) mortality were also similar. CONCLUSION: The Tandem procedure is as safe and effective as the conventional TLE. It can be applied to leads of a long dwell time with a potentially shorter procedure duration.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Humanos , Desfibriladores Implantáveis/efeitos adversos , Marca-Passo Artificial/efeitos adversos , Remoção de Dispositivo/efeitos adversos , Remoção de Dispositivo/métodos , Fatores de Tempo , Fluoroscopia , Resultado do Tratamento , Estudos Retrospectivos
2.
Europace ; 25(11)2023 11 02.
Artigo em Inglês | MEDLINE | ID: mdl-37882609

RESUMO

AIMS: Transvenous lead extraction (TLE) is performed using non-laser and laser techniques with overall high efficacy and safety. Variation in outcomes between the two approaches does exist with limited comparative evidence in the literature. We sought to compare non-laser and laser TLE in a meta-analysis. METHODS AND RESULTS: We searched Medline, Embase, Scopus, ClinicalTrials.gov, and CENTRAL databases for TLE studies published between 1991 and 2021. From the included 68 studies, safety and efficacy data were carefully evaluated and extracted. Aggregated cases of outcomes were used to calculate odds ratio (OR), and pooled rates were synthesized from eligible studies to compare non-laser and laser techniques. Subgroup comparison of rotational tool and laser extraction was also performed. Non-laser in comparison with laser had lower procedural mortality (pooled rate 0% vs. 0.1%, P < 0.01), major complications (pooled rate 0.7% vs. 1.7%, P < 0.01), and superior vena cava (SVC) injury (pooled rate 0% vs. 0.5%, P < 0.001), with higher complete success (pooled rate 96.5% vs. 93.8%, P < 0.01). Non-laser comparatively to laser was more likely to achieve clinical [OR 2.16 (1.77-2.63), P < 0.01] and complete [OR 1.87 (1.69-2.08), P < 0.01] success, with a lower procedural mortality risk [OR 1.6 (1.02-2.5), P < 0.05]. In the subgroup analysis, rotational tool compared with laser achieved greater complete success (pooled rate 97.4% vs. 95%, P < 0.01) with lower SVC injury (pooled rate 0% vs. 0.7%, P < 0.01). CONCLUSION: Non-laser TLE is associated with a better safety and efficacy profile when compared with laser methods. There is a greater risk of SVC injury associated with laser sheath extraction.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Humanos , Desfibriladores Implantáveis/efeitos adversos , Veia Cava Superior/cirurgia , Remoção de Dispositivo/efeitos adversos , Remoção de Dispositivo/métodos , Lasers , Cateterismo Cardíaco , Marca-Passo Artificial/efeitos adversos , Resultado do Tratamento , Estudos Retrospectivos
3.
J Cardiovasc Electrophysiol ; 33(1): 102-108, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34783107

RESUMO

BACKGROUND: Transvenous lead extraction (TLE) is rising in parallel to cardiac implantable electronic device implantations. Persistent left side superior vena cava (PLSVC) is a relatively common anatomical variant in the healthy population; TLE in patients with a PLSVC is rare. METHOD: Data were collated from 6 European TLE institutes of 10 patients who had undergone lead extraction with a PLSVC. Patient demographics, procedural challenges and outcomes were reported. RESULTS: Ten patients aged 73.4 ± 7.8 years (60% male) underwent TLE of 20 leads (3 left ventricle, 10 right ventricle, 7 right atrium) with dwell time of 82.95 ± 39.1 months. Of the 10 cases, 4 had an infection indication and 5 were biventricular system extractions; 25% of the extracted leads were defibrillator leads. The majority of the procedures were completed in the cardiac catheterization suite (80%) under general anaesthesia (60%) by cardiologists (80%) using a rotational powered sheath (65%). The Tandem approach was used successfully in 3 cases. Complete procedural success was obtained in 100% of cases in the absence of complications within 127.4 ± 74.7 min. There was no 30-day mortality. CONCLUSION: TLE in PLSVC is feasible albeit rare. Standard extraction techniques in experienced hands are associated with favorable outcomes; the Tandem procedure may be an additional technique to improve the safety and efficacy of TLE in PLSVC.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Veia Cava Superior Esquerda Persistente , Idoso , Idoso de 80 Anos ou mais , Desfibriladores Implantáveis/efeitos adversos , Remoção de Dispositivo/métodos , Feminino , Humanos , Masculino , Marca-Passo Artificial/efeitos adversos , Resultado do Tratamento , Veia Cava Superior/diagnóstico por imagem , Veia Cava Superior/cirurgia
4.
Pacing Clin Electrophysiol ; 45(5): 658-665, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35417049

RESUMO

BACKGROUND: With an increasing number of cardiac implantable electronic devices (CIEDs), there has been a paralleled increase in demand for transvenous lead extraction (TLE). Cardiac surgeons (CS) and cardiologists perform TLE; however, data comparing the two groups of operators is scarce. OBJECTIVE: We compared the outcomes of TLE performed by cardiologists and CS from six European lead extraction units. METHOD: Data was collected retrospectively of 2205 patients who had 3849 leads extracted (PROMET) between 2005 and 2018. Patient demographics and procedural outcomes were compared between the CS and cardiologist groups, using propensity score matching. A multivariate regression analysis was also performed for variables associated with 30-day mortality. RESULTS: CS performed the majority of extractions (59.8%), of leads with longer dwell times (90 [57-129 interquartile range (IQR)] vs. 62 [31-102 IQR] months, CS vs. cardiologists, p < .001) and with pre-dominantly non-infectious indications (57.4% vs. 50.2%, CS vs. cardiologists, p < .001). CS achieved a higher complete success per lead than the cardiologists (98.1% vs. 95.7%, respectively, p < .01), with a higher number of minor complications (5.51% vs. 2.1%, p < .01) and similar number of major complications (0.47% vs. 1.3%, p = .12). Thirty-day mortality was similarly low in the CS and cardiologist groups (1.76% vs. 0.94%, p = .21). Unmatched data multivariate analysis revealed infection indication (OR 6.12 [1.9-20.3], p < .01), procedure duration (OR 1.01 [1.01-1.02], p < .01) and CS operator (OR 2.67, [1.12-6.37], p = .027) were associated with 30-day mortality. CONCLUSION: TLE by CS was performed with similar safety and higher efficacy compared to cardiologists in high and medium-volume lead extraction centers.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Remoção de Dispositivo/métodos , Humanos , Prometazina , Estudos Retrospectivos , Resultado do Tratamento
5.
Pacing Clin Electrophysiol ; 44(9): 1540-1548, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34235772

RESUMO

BACKGROUND: Cardiac implantable electronic device (CIED) therapy contributes to an improvement in morbidity and mortality across all patient demographics. Patient age is a recognized risk factor for unfavorable outcomes in invasive procedures. This is the largest series of non-laser transvenous lead extraction (TLE) evaluating the association between patient age and procedure outcomes. METHODS: Data of 2205 (3849 leads) patients was collected retrospectively from six European TLE centers between January 2005-December 2018 in the PROMET study. Of these, 153 patients with 319 leads were excluded for incomplete data. A comparison of outcomes was performed between the age groups young [< 50 years], young intermediate [50-69 years], older intermediate [70-79 years], and octogenarian [≥80 years]. RESULTS: Infection was most common indication for TLE in the octogenarian cohort, less common in the younger population (60.1% vs. 33.2%, respectively, p < .01). High-voltage leads were extracted most frequently from young patients, less frequently from octogenarians (31.6% vs. 10%, p < .001), while the opposite was evident for pacemaker leads (p < .001). Rotational sheath use was equally prevalent across all patient groups (p = .79). Minor and major complications across all the age groups were statistically similar, as was procedural success; the 30-day mortality was most significant in the octogenarian and least in the young patients (4.9% vs. 0.4%, p = .005). Propensity matching multivariate analysis found systemic infection, lead dwell time, and patient age (p = .013, OR 1.064 [1.013-1.116]) increased risk of 30-day mortality. CONCLUSION: TLE is safe and effective across all age groups. 30-day mortality risk is significantly higher in the older patients.


Assuntos
Remoção de Dispositivo/métodos , Eletrodos Implantados , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Europa (Continente) , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
6.
Surg Technol Int ; 37: 263-269, 2021 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-33463696

RESUMO

Implantable left ventricular assist devices (durable LVADs) have dramatically improved mortality and morbidity in patients with advanced heart failure. Originally designed as a bridge or candidacy to heart transplantation, the indications extend toward permanent support and palliation. Modern durable continuous flow LVADs are small, commercially available, and allow for different surgical approaches to a wide range of patients with various cardiac pathologies. We will review different surgical implantation techniques of modern continuous flow LVADs, as well as specific aspects of preoperative patient evaluation and planning.


Assuntos
Insuficiência Cardíaca , Transplante de Coração , Coração Auxiliar , Insuficiência Cardíaca/cirurgia , Ventrículos do Coração , Humanos
7.
Europace ; 22(1): 133-138, 2020 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-31638648

RESUMO

AIMS: Treatment of patients with systemic cardiac implantable electronic device (CIED) infection with large lead vegetations is challenging and associated with relevant morbidity and mortality. To avoid complications from open surgical extraction, a novel approach with percutaneous aspiration of large vegetations prior to transvenous lead extraction was instituted. The results of this treatment concept were retrospectively analysed in this multicentre study. METHODS AND RESULTS: One hundred and one patients [mean age 68.2 ± 13.1 (30-92) years] were treated in four centres for endovascular CIED infection with large lead vegetations. Mean lead vegetation size was 30.7 ± 13.5 mm. Two hundred and forty-seven leads were targeted for extraction (170 pacemaker leads, 77 implantable cardioverter-defibrillator leads). Mean lead implant duration was 81.7 (1-254) months. The transcatheter aspiration system with a specialized long venous drainage cannula and a funnel-shaped tip was based on a veno-venous extracorporeal circuit with an in-line filter. The aspiration of vegetations showed complete procedural success in 94.0% (n = 95), partial success in 5.0% (n = 5). Three major complications (3.0%) were encountered. Complete procedural success (per lead) of the subsequently performed transvenous lead extraction procedure was 99.2% (n = 245). Thirty-day mortality was 3.0% (n = 3). Five patients (5.0%) died in the further course on Days 51, 54, 68, 134, and 182 post-procedure (septic complications: n = 4; heart failure: n = 1). CONCLUSION: The percutaneous aspiration procedure is highly effective and is associated with a low complication profile. The aspiration of vegetations immediately prior and during the lead extraction procedure may avoid septic embolization into the pulmonary circulation. This may potentially lead to a long-term survival benefit.


Assuntos
Desfibriladores Implantáveis , Remoção de Dispositivo , Marca-Passo Artificial , Adulto , Idoso , Idoso de 80 Anos ou mais , Desfibriladores Implantáveis/efeitos adversos , Humanos , Pessoa de Meia-Idade , Marca-Passo Artificial/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento
8.
Europace ; 22(7): 1103-1110, 2020 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-32447388

RESUMO

AIMS: Several large studies have documented the outcome of transvenous lead extraction (TLE), focusing on laser and mechanical methods. To date there has been no large series addressing the results obtained with rotational lead extraction tools. This retrospective multicentre study was designed to investigate the outcomes of mechanical and rotational techniques. METHODS AND RESULTS: Data were collected on a total of 2205 patients (age 66.0 ± 15.7 years) with 3849 leads targeted for extraction in six European lead extraction centres. The commonest indication was infection (46%). The targeted leads included 2879 pacemaker leads (74.8%), 949 implantable cardioverter-defibrillator leads (24.6%), and 21 leads for which details were unknown; 46.6% of leads were passive fixation leads. The median lead dwell time was 74 months [interquartile range (IQR) 41-112]. Clinical success was obtained in 97.0% of procedures, and complete extraction was achieved for 96.5% of leads. Major complications occurred in 22/2205 procedures (1%), with a peri-operative or procedure-related mortality rate of 4/2205 (0.18%). Minor complications occurred in 3.1% of procedures. A total of 1552 leads (in 992 patients) with a median dwell time of 106 months (IQR 66-145) were extracted using the Evolution rotational TLE tool. In this subgroup, complete success was obtained for 95.2% of leads with a procedural mortality rate of 0.4%. CONCLUSION: Patient outcomes in the PROMET study compare favourably with other large TLE trials, underlining the capability of rotational TLE tools and techniques to match laser methods in efficacy and surpass them in safety.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Idoso , Idoso de 80 Anos ou mais , Desfibriladores Implantáveis/efeitos adversos , Remoção de Dispositivo , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
9.
Artif Organs ; 41(10): 948-958, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28691283

RESUMO

The technology of 3D-printing has allowed the production of entirely soft pumps with complex chamber geometries. We used this technique to develop a completely soft pneumatically driven total artificial heart from silicone elastomers and evaluated its performance on a hybrid mock circulation. The goal of this study is to present an innovative concept of a soft total artificial heart (sTAH). Using the form of a human heart, we designed a sTAH, which consists of only two ventricles and produced it using a 3D-printing, lost-wax casting technique. The diastolic properties of the sTAH were defined and the performance of the sTAH was evaluated on a hybrid mock circulation under various physiological conditions. The sTAH achieved a blood flow of 2.2 L/min against a systemic vascular resistance of 1.11 mm Hg s/mL (afterload), when operated at 80 bpm. At the same time, the mean pulmonary venous pressure (preload) was fixed at 10 mm Hg. Furthermore, an aortic pulse pressure of 35 mm Hg was measured, with a mean aortic pressure of 48 mm Hg. The sTAH generated physiologically shaped signals of blood flow and pressures by mimicking the movement of a real heart. The preliminary results of this study show a promising potential of the soft pumps in heart replacements. Further work, focused on increasing blood flow and in turn aortic pressure is required.


Assuntos
Coração Artificial , Hemodinâmica , Impressão Tridimensional , Pressão Arterial , Pressão Sanguínea , Humanos , Teste de Materiais/instrumentação , Modelos Cardiovasculares , Desenho de Prótese , Resistência Vascular
10.
Europace ; 18(2): 253-6, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25995394

RESUMO

AIMS: We investigated the safety and efficacy of a new bidirectional rotational mechanical extraction sheath (Evolution RL, Cook Medical, USA). METHODS AND RESULTS: From April 2013 until September 2014, we performed lead extraction procedures in 71 patients with 112 leads scheduled for extraction. During this time period, we used the new Evolution RL rotational sheath in 40 patients on 52 leads (24 pacemaker leads and 28 implantable cardioverter-defibrillator leads) scheduled for extraction. The mean lead implant duration in these patients was 100.2 (22-271) months. Forty leads were right ventricular leads, 10 right atrial leads, and 2 coronary sinus leads. Clinical success among the leads approached with the Evolution RL device was 98.1%. Operative mortality was zero. Major complications did not occur. Four minor complications were encountered (all pocket haematomas). No device-related complications were noted. In cases with multiple leads in situ, no wrapping of companion leads was seen. The average number of extraction tools used per lead was 2.4 (2-4) in the Evolution RL cohort. CONCLUSION: Based on the presented results of our initial experience with the new bidirectional rotational mechanical extraction device, its use is safe and efficient with high success rates in long implanted leads.


Assuntos
Cateterismo Cardíaco/métodos , Cateteres Cardíacos , Desfibriladores Implantáveis , Remoção de Dispositivo/instrumentação , Marca-Passo Artificial , Adulto , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco/efeitos adversos , Remoção de Dispositivo/efeitos adversos , Remoção de Dispositivo/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Estudos Retrospectivos , Resultado do Tratamento
11.
Europace ; 17(3): 499-503, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25345832

RESUMO

AIMS: We investigated a new lead extraction tool (Compression Coil; One-Tie, Cook Medical) in an experimental traction force study. METHODS AND RESULTS: On 13 pacemaker leads (Setrox JS53, Biotronik) traction force testing was performed under different configurations. The leads were assigned to three groups: (i) traction force testing without central locking stylet support (n = 5), (ii) traction force testing with the use of a locking stylet (Liberator, Cook Medical) and a proximal ligation suture (n = 4), (iii) traction force testing with the use of a locking stylet and a compression coil (n = 4). The following parameters were obtained for all groups: stress-strain curves, maximal forces, elastic modulus, post-testing lead length and lead elongation. In Groups 2 and 3 retraction of the locking stylet within the lead was measured [lead tip-locking stylet distance (LTLSD)]. Maximal forces for the three groups were: (i) 28.3 ± 0.3 N; (ii) 30.6 ± 3.0 N; (iii) 31.6 ± 2.9 N (1 vs. 2, P = 0.13; 1 vs. 3, P = 0.04; 2 vs. 3, P = 0.65). Elastic modulus was (i) 22.8 ± 0.1 MPa; (ii) 2830.8 ± 351.1 MPa; (iii) 2447.0 ± 510.5 MPa (1 vs. 2, P < 0.01; 1 vs. 3, P < 0.01; 2 vs. 3, P = 0.26). Mean LTLSD in Group 2 was 19.8 ± 3.2 cm and was 13.8 ± 1.7 cm in Group 3 (P = 0.02). The ratio of LTLSD/post-testing lead length was 0.37 ± 0.03 for Group 2 and 0.24 ± 0.03 for Group 3 (P < 0.01). CONCLUSION: The application of a compression coil leads to an increased lead control expressed by less retraction of the locking stylet within the lead. This enables improved central support of extraction sheaths in the case of challenging extraction procedures.


Assuntos
Remoção de Dispositivo/instrumentação , Eletrodos Implantados , Marca-Passo Artificial , Humanos
12.
J Card Surg ; 30(2): 145-8, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25533356

RESUMO

A noncellular xenogeneic extracellular matrix derived from the porcine small intestinal submucosa can be used as a new patch material with potential advantages. We review the literature on the use of this material in cardiac surgery.


Assuntos
Bioprótese , Procedimentos Cirúrgicos Cardíacos/métodos , Matriz Extracelular/transplante , Xenoenxertos , Mucosa Intestinal/transplante , Intestino Delgado/transplante , Idoso , Animais , Feminino , Ventrículos do Coração/cirurgia , Humanos , Infarto do Miocárdio/cirurgia , Suínos
13.
Eur Heart J ; 35(16): 1051-60, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24371079

RESUMO

BACKGROUND: Cardiac resynchronization therapy (CRT) is associated with improved morbidity and mortality in patients with chronic heart failure (CHF) on optimal medical therapy. The impact of CHF medication optimization following CRT, however, has never been comprehensively evaluated. In the current study, we therefore investigated the effect of CHF medication dosage on morbidity and mortality in CHF patients after CRT implantation. METHODS AND RESULTS: Chronic heart failure medication was assessed in 185 patients after CRT implantation. During an overall mean follow-up of 44.6 months, 83 patients experienced a primary endpoint (death, heart transplantation, assist device implantation, or hospitalization for CHF). Treatment with higher dosages of angiotensin-converting enzyme inhibitor (ACE-I) or angiotensin receptor blockers (ARBs) (P = 0.001) and beta-blockers (P < 0.001) as well as with lower dosages of loop diuretics (P < 0.001) was associated with a reduced risk for the primary combined endpoint as well as for all-cause mortality. Echocardiographic super-responders to CRT were treated with higher average dosages of ACE-I/ARBs (68.1 vs. 52.4%, P < 0.01) and beta-blockers (59 vs. 42.2%, P < 0.01). During follow-up, the average dosage of loop diuretics was decreased by 20% in super-responders, but increased by 30% in non-super-responders (P < 0.03). CONCLUSION: The use of higher dosages of neurohormonal blockers and lower dosages of diuretics is associated with reduced morbidity and mortality following CRT implantation. Our data imply a beneficial effect of increasing neurohormonal blockade whenever possible following CRT implantation.


Assuntos
Cardiotônicos/administração & dosagem , Insuficiência Cardíaca/terapia , Antagonistas Adrenérgicos beta/administração & dosagem , Antagonistas de Receptores de Angiotensina/administração & dosagem , Inibidores da Enzima Conversora de Angiotensina/administração & dosagem , Terapia de Ressincronização Cardíaca , Terapia Combinada , Relação Dose-Resposta a Droga , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Ensaios Clínicos Controlados Aleatórios como Assunto , Inibidores de Simportadores de Cloreto de Sódio e Potássio/administração & dosagem , Resultado do Tratamento
14.
Acta Cardiol ; 70(5): 581-6, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26567818

RESUMO

OBJECTIVE: We aimed to analyse whether different lead implantation techniques influence lead failure based on implant duration. METHODS AND RESULTS: Eighty-two transvenous leads were extracted due to lead failure. Median implant duration (MID) of the extracted leads was 68 months. Failed leads were retrospectively divided into 5 subgroups according to predefined technical procedural aspects, potentially triggering lead failure: venous approach, lead disorder in the generator pocket, sharp lead angulation, lead-lead interaction and number of leads in situ. The subgroups were correlated to the MID and compared. The MID was 81 vs 59 months in medial vs lateral venous puncture (P=0.453). In subgroups without/with lead disorder the MID was 59 vs 107 months (P=0.006) and 57 vs 84 months (P=0.012) in subgroups without/with sharp lead angulation, respectively. In subgroups without/with more than 1 lead-lead interaction the MID was 59 vs 81 months (P=0.029) and 65 vs 86 months (P=0.128) without/with more than 2 lead-lead interactions, respectively. In subgroups without/with more than 1 lead in situ the MID was 73 vs 67 months (P=0.453), 81 vs 27 months (P=0.296) in subgroups without/with more than 2 leads in situ and 68 vs 77 months (P=0.264) in subgroups without/with more than 3 leads in situ, respectively. CONCLUSIONS: Although, we were able to confirm our hypothesis only partially, technical aspects of lead implantation technique should be kept in mind as a potential reason causing lead failure.


Assuntos
Estimulação Cardíaca Artificial , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Marca-Passo Artificial , Implantação de Prótese/instrumentação , Implantação de Prótese/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Remoção de Dispositivo , Falha de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Estudos Retrospectivos , Resultado do Tratamento
15.
Artigo em Inglês | MEDLINE | ID: mdl-38193462

RESUMO

With the increasing use of cardiac implantable electronic devices, the number of patients with cardiac implantable electronic device-related endocarditis is also rising. The treatment of this type of endocarditis is a challenging clinical task, in particular if device removal is required in patients who are pacemaker dependent. This video tutorial describes a treatment strategy for cardiac implantable electronic device-related endocarditis involving the tricuspid valve in pacemaker-dependent patients. The proposed treatment strategy consists of implanting an epicardial pacemaker via a minimally invasive subxiphoid approach, percutaneous aspiration of tricuspid valve vegetations and complete transvenous explantation of the infected cardiac implantable electronic device system using advanced lead extraction tools.


Assuntos
Endocardite , Marca-Passo Artificial , Humanos , Endocardite/etiologia , Endocardite/cirurgia , Próteses e Implantes , Valva Tricúspide , Eletrônica , Marca-Passo Artificial/efeitos adversos
16.
J Clin Med ; 13(2)2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-38256608

RESUMO

BACKGROUND: Takotsubo syndrome is, by definition, a reversible form of acute heart failure. If cardiac output is severely reduced, Takotsubo syndrome can cause cardiogenic shock, and mechanical circulatory support can serve as a bridge to recovery. To date, there are no recommendations on when to use mechanical circulatory support and on which device is particularly effective in this context. Our aim was to determine the best treatment strategy. METHODS: A systematic literature research and analysis of individual patient data was performed in MEDLINE/PubMed according to PRISMA guidelines. Our research considered original works published until 31 July 2023. RESULTS: A total of 93 publications that met the inclusion criteria were identified, providing individual data from 124 patients. Of these, 62 (50%) were treated with veno-arterial extracorporeal life support (va-ECLS), and 44 (35.5%) received a microaxial left ventricular assist device (Impella). Eighteen patients received an Impella CP and twenty-one an Impella 2.5. An intra-aortic balloon pump (IABP) without other devices was used in only 13 patients (10.5%), while other devices (BiVAD or Tandem Heart) were used in 5 patients (4%). The median initial left ventricular ejection fraction was 20%, with no difference between the four device groups except for the IABP group, which was less affected by cardiac output failure (p = 0.015). The overall survival was 86.3%. Compared to the other groups, the time to cardiac recovery was shorter with Impella (p < 0.001). CONCLUSIONS: Though the Impella treatment is new, our analysis may show a significant benefit of Impella compared to other MCS strategies for cardiogenic shock in Takotsubo syndrome.

17.
Europace ; 15(11): 1636-41, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23585255

RESUMO

AIMS: In this retrospective study we compared different lead extraction techniques. METHODS AND RESULTS: Between January 2009 and December 2012 we performed transvenous lead extraction procedures on 206 leads in 122 patients. Mean implant duration (MID) was 69.6 months (1-384 months). Leads with lead implant duration ≥ 12 months were assigned to groups according to the extraction technique: Group A: no extraction tool; Group B: laser approach; and Group C: mechanical approach. Overall clinical success was 93.3%. Group A showed a significantly lower MID [38.1 (19-122) months] compared with Groups B and C [83.1 (13-168) months; P < 0.0001 vs. 95.4 (12-384) months; P < 0.0001]. Mean implant duration between Groups B and C did not differ significantly (P = 0.28). Clinical and complete procedural success was 100% in Group A. Clinical success rate was higher in Group C than in Group B (97.0 vs. 76.9%, P = 0.018). Complete procedural success did not differ significantly between Groups B and C (88.9 vs. 76.9%; P = 0.132). In Groups B and C, absence of complete procedural success occurred in long implanted leads (MID 107.8 ± 36.4 and 137.6 ± 89.2 months). Relative costs per extracted lead were 49% higher in Group B than in Group C. CONCLUSION: In case of long implanted leads a laser and a mechanical approach are comparable in complete procedural success and safety. Clinical success and cost effectiveness analysis favours the mechanical approach. Regardless of the extraction technique efficacy and safety optimization has to focus on long implanted leads.


Assuntos
Remoção de Dispositivo/métodos , Insuficiência Cardíaca/terapia , Lasers , Mecânica , Marca-Passo Artificial/efeitos adversos , Adulto , Idoso , Idoso de 80 Anos ou mais , Dor Crônica/etiologia , Análise Custo-Benefício , Remoção de Dispositivo/economia , Feminino , Humanos , Infecções/etiologia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Trombose/etiologia , Fatores de Tempo , Resultado do Tratamento
18.
Pacing Clin Electrophysiol ; 36(9): 1111-6, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23713912

RESUMO

OBJECTIVES: Pacemaker (PM) and implantable cardioverter defibrillator (ICD) leads become encapsulated intravascularly and in the generator pocket by fibrotic adhesions that accumulate over time. These adhesions are responsible for the difficulty and risk of lead extraction procedures. We developed a classification scheme for pocket adhesions, classified all of the patients in the cohort, and examined the relationship between pocket adhesions and the outcome of the procedure. METHODS: The classification of adhesions with respect to the intraoperative adhesion coverage was as followed: class 0 = adhesion free; class 1 ≤ 30% of adhesion coverage; class 2 = 30-60% of adhesion coverage; and class 3 ≥ 60% coverage. Patient data between December 2010 and March 2012 were collected. A total of 100 leads were extracted from 58 patients (1.7 ± 0.8 leads/patient); the mean lead implant duration was 78.5 ± 66.7 months, and the percentage of PM/ICD leads was 68% (n = 68)/32% (n = 32). RESULTS: Distribution of the leads among classes: 0 = 10; 1 = 17; 2 = 25; and 3 = 48. Average implant times (months) according to the adhesion classes: 0 = 1.2 ± 0.4; 1 = 19.8 ± 19.2; 2 = 79.3 ± 46.6; and 3 = 115.1 ± 106.0 (correlation-coefficient 0.71; P ≤ 0.05). Average numbers of extraction tools used according to the adhesions: 0 = none; 1 = 0.4 ± 0.7; 2 = 1.6 ± 1.0; and 3 = 2.3 ± 1.2 (correlation coefficient = 0.67; P ≤ 0.05). Complete removal was achieved in 100% of the patients in classes 0 and 1; 96% in class 2 (n = 24); and 75% in class 3 (n = 36) (P ≤ 0.05). Mortality = 0. CONCLUSIONS: Extensive adhesions in the generator pocket predict the need for a higher number of extraction tools. High-grade pocket adhesions predict lower success rates with regard to complete lead extraction. Both findings suggest that the degree of pocket adhesions predicts the degree of intravascular adhesions.


Assuntos
Desfibriladores Implantáveis/efeitos adversos , Eletrodos Implantados/efeitos adversos , Marca-Passo Artificial/efeitos adversos , Aderências Teciduais/diagnóstico , Aderências Teciduais/etiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Remoção de Dispositivo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Índice de Gravidade de Doença , Aderências Teciduais/classificação
19.
J Surg Case Rep ; 2023(7): rjad389, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37416493

RESUMO

Implantation of a temporary percutaneous right ventricular assist device (RVAD) in patients with right heart failure after left ventricular assist device (LVAD) implantation is an established technique that may cause complications. We present a 60-year-old male patient who underwent urgent LVAD implantation. On the second postoperative day the patient developed acute right heart failure. We implanted a temporary percutaneous RVAD with two cannulas via the right internal jugular vein and the right femoral vein. Transesophageal echocardiography revealed severe pulmonary insufficiency. After performing re-sternotomy we anastomosed a prosthetic graft to the pulmonary trunk (PT), performed subxiphoid tunneling of the graft and replaced the transjugular outflow cannula. The pulmonary regurgitation caused by the percutaneous transvalvular cannula disappeared. In such case a direct anastomosis to the PT is the solution.

20.
J Cardiothorac Surg ; 18(1): 343, 2023 Nov 27.
Artigo em Inglês | MEDLINE | ID: mdl-38012790

RESUMO

OBJECTIVES: Cardiogenic shock (CS) can occur in patients with Takotsubo syndrome (TTS). As TTS has received increasing attention and has been more closely researched, several aspects of the pathogenesis have been identified, particularly that an excessive release of catecholamines plays an important role. Nevertheless, evidence on specific therapy concepts is still lacking. As a result, TTS with severe hemodynamic instability and low cardiac output creates unique challenges, and mechanical circulatory support is needed with as few inotropic drugs as possible. METHODS: We present a 77-year-old female patient who underwent minimally invasive surgical mitral valve replacement. After an uneventful course, the patient developed acute heart failure eleven days after surgery. Transthoracic echocardiography (TTE) revealed a new onset of TTS. The patient needed left ventricular venting and full haemodynamic flow. We successfully implanted a microaxial left ventricular assist device (Impella 5.5) using the transaxillary approach. The haemodynamic situation stabilised immediately. The patient was weaned and the Impella 5.5 was explanted after five days. CONCLUSION: We present the first-in-man implantation of a transaxillary Impella 5.5 in a patient with TTS. The patient benefitted from Impella 5.5 therapy with full haemodynamic support and venting of the left ventricle.


Assuntos
Coração Auxiliar , Cardiomiopatia de Takotsubo , Feminino , Humanos , Idoso , Choque Cardiogênico/etiologia , Choque Cardiogênico/cirurgia , Coração Auxiliar/efeitos adversos , Cardiomiopatia de Takotsubo/complicações , Cardiomiopatia de Takotsubo/cirurgia , Resultado do Tratamento , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa