Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Resusc Plus ; 18: 100604, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38510376

RESUMO

Aim: To determine whether targeting mild hypercapnia (PaCO2 7 kPa) would yield improved cerebral blood flow and metabolism compared to normocapnia (PaCO2 5 kPa) with and without targeted temperature management to 33 °C (TTM33) in a porcine post-cardiac arrest model. Methods: 39 pigs were resuscitated after 10 minutes of cardiac arrest using cardiopulmonary bypass and randomised to TTM33 or no-TTM, and hypercapnia or normocapnia. TTM33 was managed with intravasal cooling. Animals were stabilized for 30 minutes followed by a two-hour intervention period. Hemodynamic parameters were measured continuously, and neuromonitoring included intracranial pressure (ICP), pressure reactivity index, cerebral blood flow, brain-tissue pCO2 and microdialysis. Measurements are reported as proportion of baseline, and areas under the curve during the 120 min intervention period were compared. Results: Hypercapnia increased cerebral flow in both TTM33 and no-TTM groups, but also increased ICP (199% vs. 183% of baseline, p = 0.018) and reduced cerebral perfusion pressure (70% vs. 84% of baseline, p < 0.001) in no-TTM animals. Cerebral lactate (196% vs. 297% of baseline, p < 0.001), pyruvate (118% vs. 152% of baseline, p < 0.001), glycerol and lactate/pyruvate ratios were lower with hypercapnia in the TTM33 group, but only pyruvate (133% vs. 150% of baseline, p = 0.002) was lower with hypercapnia among no-TTM animals. Conclusion: In this porcine post-arrest model, hypercapnia led to increased cerebral flow both with and without hypothermia, but also increased ICP and reduced cerebral perfusion pressure in no-TTM animals. The effects of hypercapnia were different with and without TTM.(Institutional protocol number: FOTS, id 14931).

2.
Biomed Pharmacother ; 137: 111392, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33761609

RESUMO

Inflammation and oxidative stress play a significant role in the pathogenesis of nonalcoholic steatohepatitis (NASH). Ethyl pyruvate (EP) is a novel anti-inflammatory agent and a potent reactive oxygen species (ROS) scavenger. Therefore, EP supplemented in drinking water may alleviate experimental NASH in this study (even though 0.3% of EP cannot attenuate the simple non-aggressive fatty liver). The methionine-choline-deficient (MCD) diet was given to the C57BL/6 male mice for 3 weeks to induce NASH. The NASH animals were randomized into 3 treatment groups: animals in the MCD alone group were treated with normal drinking water alone; animals in the delayed EP group were given 3% (v/v) of EP supplemented in normal drinking water, the treatment started 10 days after MCD diet feeding; animals in the early EP therapy group were treated the same as the delayed EP group except that EP treatment started the same day when MCD diet was given; the control mice were fed with normal chow and treated with normal drinking water (n = 10 for each group). Compared to MCD group with normal drinking water, early EP treatment significantly decreased serum ALT and improved NASH histopathology; delayed EP therapy only attenuated NASH in 50% (5/10) of the animals. The beneficial effects were associated with decreased hepatic TNF-a and IL-6 mRNA expression on early 5 days, inhibited NF-kB activation, reduced liver tissue malondialdehyde levels, and decreased intestinal bacterial translocation (BT). In conclusion: EP supplemented in drinking water attenuates experimental NASH.


Assuntos
Antioxidantes/uso terapêutico , Água Potável , Hepatopatia Gordurosa não Alcoólica/tratamento farmacológico , Piruvatos/uso terapêutico , Animais , Antioxidantes/administração & dosagem , Translocação Bacteriana , Dieta , Interleucina-6/biossíntese , Fígado/metabolismo , Fígado/patologia , Testes de Função Hepática , Masculino , Malondialdeído/metabolismo , Metionina/deficiência , Camundongos , Camundongos Endogâmicos C57BL , NF-kappa B/efeitos dos fármacos , Hepatopatia Gordurosa não Alcoólica/patologia , Estresse Oxidativo/efeitos dos fármacos , Piruvatos/administração & dosagem , Fator de Necrose Tumoral alfa/metabolismo
3.
Resuscitation ; 167: 251-260, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34166747

RESUMO

AIM: To determine whether targeting a mean arterial pressure of 90 mmHg (MAP90) would yield improved cerebral blood flow and less ischaemia compared to MAP 60 mmHg (MAP60) with and without targeted temperature management at 33 °C (TTM33) in a porcine post-cardiac arrest model. METHODS: After 10 min of cardiac arrest, 41 swine of either sex were resuscitated until return of spontaneous circulation (ROSC). They were randomised to TTM33 or no-TTM, and MAP60 or MAP90; yielding four groups. Temperatures were managed with intravasal cooling and blood pressure targets with noradrenaline, vasopressin and nitroprusside, as appropriate. After 30 min of stabilisation, animals were observed for two hours. Cerebral perfusion pressure (CPP), cerebral blood flow (CBF), pressure reactivity index (PRx), brain tissue pCO2 (PbtCO2) and tissue intermediary metabolites were measured continuously and compared using mixed models. RESULTS: Animals randomised to MAP90 had higher CPP (p < 0.001 for both no-TTM and TTM33) and CBF (no-TTM, p < 0.03; TH, p < 0.001) compared to MAP60 during the 150 min observational period post-ROSC. We also observed higher lactate and pyruvate in MAP60 irrespective of temperature, but no significant differences in PbtCO2 and lactate/pyruvate-ratio. We found lower PRx (indicating more intact autoregulation) in MAP90 vs. MAP60 (no-TTM, p = 0.04; TTM33, p = 0.03). CONCLUSION: In this porcine cardiac arrest model, targeting MAP90 led to better cerebral perfusion and more intact autoregulation, but without clear differences in ischaemic markers, compared to MAP60. INSTITUTIONAL PROTOCOL NUMBER: FOTS, id 8442.


Assuntos
Reanimação Cardiopulmonar , Parada Cardíaca , Hipotermia Induzida , Animais , Pressão Arterial , Circulação Cerebrovascular , Parada Cardíaca/terapia , Perfusão , Suínos
4.
Physiol Meas ; 39(10): 105011, 2018 10 24.
Artigo em Inglês | MEDLINE | ID: mdl-30207981

RESUMO

OBJECTIVE: Evaluation of intestinal viability is essential in surgical decision-making in patients with acute intestinal ischemia. There has been no substantial change in the mortality rate (30%-93%) of patients with acute mesenteric ischemia (AMI) since the 1980s. As the accuracy from the first laparotomy alone is 50%, the gold standard is a second-look laparotomy, increasing the accuracy to 87%-89%. This study investigates the use of machine learning to classify intestinal viability and histological grading in pig jejunum, based on multivariate time-series of bioimpedance sensor data. APPROACH: We have previously used a bioimpedance sensor system to acquire electrical parameters from perfused, ischemic and reperfused pig jejunum (7 + 15 pigs) over 1-16 h of ischemia and 1-8 h of reperfusion following selected durations of ischemia. In this study we compare the accuracy of using end-point bioimpedance measurements with a feedforward neural network (FNN), versus the accuracy when using a recurrent neural network with long short-term memory units (LSTM-RNN) with bioimpedance data history over different periods of time. MAIN RESULTS: Accuracies in the range of what has been reported clinically can be achieved using FNN's on a single bioimpedance measurement, and higher accuracies can be achieved when employing LSTM-RNN on a sequence of data history. SIGNIFICANCE: Intraoperative bioimpedance measurements on intestine of suspect viability combined with machine learning can increase the accuracy of intraoperative assessment of intestinal viability. Increased accuracy in intraoperative assessment of intestinal viability has the potential to reduce the high mortality and morbidity rate of the patients.


Assuntos
Enteropatias/diagnóstico , Isquemia/diagnóstico , Isquemia/fisiopatologia , Jejuno/fisiopatologia , Jejuno/cirurgia , Aprendizado de Máquina , Monitorização Intraoperatória/métodos , Animais , Tomada de Decisão Clínica/métodos , Impedância Elétrica , Feminino , Interpretação de Imagem Assistida por Computador/métodos , Enteropatias/patologia , Enteropatias/fisiopatologia , Enteropatias/cirurgia , Isquemia/patologia , Isquemia/cirurgia , Jejuno/patologia , Masculino , Prognóstico , Sus scrofa
5.
World J Gastroenterol ; 24(18): 2009-2023, 2018 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-29760544

RESUMO

AIM: To investigate viability assessment of segmental small bowel ischemia/reperfusion in a porcine model. METHODS: In 15 pigs, five or six 30-cm segments of jejunum were simultaneously made ischemic by clamping the mesenteric arteries and veins for 1 to 16 h. Reperfusion was initiated after different intervals of ischemia (1-8 h) and subsequently monitored for 5-15 h. The intestinal segments were regularly photographed and assessed visually and by palpation. Intraluminal lactate and glycerol concentrations were measured by microdialysis, and samples were collected for light microscopy and transmission electron microscopy. The histological changes were described and graded. RESULTS: Using light microscopy, the jejunum was considered as viable until 6 h of ischemia, while with transmission electron microscopy the ischemic muscularis propria was considered viable until 5 h of ischemia. However, following ≥ 1 h of reperfusion, only segments that had been ischemic for ≤ 3 h appeared viable, suggesting a possible upper limit for viability in the porcine mesenteric occlusion model. Although intraluminal microdialysis allowed us to closely monitor the onset and duration of ischemia and the onset of reperfusion, we were unable to find sufficient level of association between tissue viability and metabolic markers to conclude that microdialysis is clinically relevant for viability assessment. Evaluation of color and motility appears to be poor indicators of intestinal viability. CONCLUSION: Three hours of total ischemia of the small bowel followed by reperfusion appears to be the upper limit for viability in this porcine mesenteric ischemia model.


Assuntos
Mucosa Intestinal/patologia , Jejuno/patologia , Traumatismo por Reperfusão/patologia , Sobrevivência de Tecidos , Animais , Cor , Feminino , Motilidade Gastrointestinal , Mucosa Intestinal/irrigação sanguínea , Mucosa Intestinal/diagnóstico por imagem , Mucosa Intestinal/ultraestrutura , Jejuno/irrigação sanguínea , Jejuno/diagnóstico por imagem , Jejuno/ultraestrutura , Masculino , Oclusão Vascular Mesentérica/complicações , Microdiálise , Microscopia Eletrônica de Transmissão , Fotografação , Traumatismo por Reperfusão/diagnóstico por imagem , Traumatismo por Reperfusão/etiologia , Sus scrofa , Suínos , Fatores de Tempo
6.
Physiol Meas ; 39(2): 025001, 2018 02 26.
Artigo em Inglês | MEDLINE | ID: mdl-29303488

RESUMO

OBJECTIVE: Trans-intestinal bioimpedance measurements have previously been used to investigate changes in electrical parameters during 6 h of ischemia in the small intestine. Knowledge is lacking regarding the time course of trans-intestinal bioimpedance parameters during reperfusion. As reperfusion is an important part in the clinical treatment of intestinal ischemia, we need to know how it affects the bioimpedance measurements. APPROACH: We performed bioimpedance measurements, using a two-electrode setup on selected segments of the jejunum in 15 pigs. A controlled voltage signal was applied while measuring the resulting current. In each pig, five or six 30 cm segments of the jejunum were made ischemic by clamping the mesenteric arteries and veins creating segments with ischemia from 1-16 h duration. Reperfusion was initiated at selected time intervals of ischemia, and measured for 5-15 h afterwards. MAIN RESULTS: The tan δ parameter (loss tangent) was different (p < 0.016) comparing ischemic and control tissue for the duration of the experiment (16 h). Comparing the control tissue 30 cm from the ischemic area with the control tissue 60 cm from the ischemic tissue, we found that the mean tan δ amplitude in the frequency range (3900-6300 Hz) was significantly higher (p < 0.036) in the proximal control after 10 h of experiment duration. After reperfusion, the time development of tanδm (loss tangent maximum over a frequency range) amplitude and frequency overlapped and periodically increased above the tanδm in the ischemic intestine. Dependent on the ischemic duration pre-reperfusion, the initial increase in tan δ stabilizes or increases drastically over time, compared to the tan δ amplitude of the ischemic tissue. SIGNIFICANCE: As during ischemia, the electrical parameters during reperfusion also follow a characteristic time-course, depending on the ischemic exposure before pre-reperfusion. The temporal changes in electrical parameters during small intestinal ischemia followed by reperfusion provides important information for assessment of tissue injury.


Assuntos
Isquemia/patologia , Isquemia/fisiopatologia , Jejuno/irrigação sanguínea , Reperfusão , Animais , Impedância Elétrica , Feminino , Jejuno/patologia , Masculino , Suínos , Sobrevivência de Tecidos
7.
Physiol Meas ; 38(5): 715-728, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28319030

RESUMO

OBJECTIVE: Bioimpedance has been used to investigate changes in electrical parameters during ischemia in various tissues. The small intestine is a multi-layered structure, with several distinct tissue types, and ischemia related changes occur at different times in the different intestinal layers. When investigating how the electrical properties in the small intestine is affected by ischemia, some researchers have used ex vivo models while others have used in vivo models. In this study, we compare ischemic time development of electrical parameters in ischemic in vivo versus ex vivo small intestine. APPROACH: Measurements were performed using a two-electrode setup, with a Solartron 1260/1294 impedance gain-phase analyser. Electrodes were placed on the surface of ischemic pig jejunum, applying a voltage and measuring the resulting electrical admittance. In each pig, 4 segments of the jejunum were made ischemic by clamping the mesenteric arteries and veins, resulting in a 30 cm central zone of warm ischemia and edema. The in vivo part of the experiment lasted 10 h, after which 3 pieces of perfused small intestine were resected, stored in Ringer-acetat at 38 °C, and measured during a 10 h ex vivo experiment. Main results and significance: We found significant differences (p < 0.0001) between the values of electric parameters when comparing the in vivo and ex vivo measurements as a function of ischemic time development. We also observed some similarities in the trends. In vivo, we measured an overall decrease in impedance during the duration of the experiment, probably as a result from the formation of edema. Ex vivo, the low frequency impedance increased initially for approximately 3 h before starting to decrease.


Assuntos
Intestino Delgado/irrigação sanguínea , Isquemia/patologia , Animais , Impedância Elétrica , Eletrodos , Feminino , Masculino , Sus scrofa
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa