Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 95
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
J Mater Sci Mater Med ; 32(6): 61, 2021 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-34021848

RESUMO

OBJECTIVES: The purpose of this study was to determine the level of periodontal tissue regeneration in a canine model following post-extraction placement of an implant molded from a composite material made from extracted tooth dentin and a calcium silicate cement (CSC) material. The investigation used autologous dentin in conjunction with a CSC material to form a composite implant designed for immediate tooth replacement. METHODS: Two (2) beagles had a periodontal and radiographic examination performed to rule out any pre-treatment inflammation, significant periodontal disease, or mobility. Then, ination eleven (11) teeth were extracted and polyvinyl siloxane molds were made to fabricate three different types of implants: Particulate Implant (Test Group 1, n = 4), Shell Implant Alone (Test Group 2, n = 2), Shell Implant with Emdogain® (Test Group 3, n = 3). Teeth in the control group were extracted, scaled (n = 2), and then re-implanted into their respective fresh extraction sockets. At 4 weeks, a clinical, radiographic, and histologic assessment was performed. RESULTS: Clinical evaluation revealed no mobility in any of the test or control implants and no radiographic evidence of significant bone loss or active disease. Based on the MicroCT analysis, direct bone to implant contact was observed in some areas with an apparent periodontal ligament space. Implant-related inflammation, on average, was similar among all groups, with low numbers of infiltrates. Implant-related inflammatory reaction was generally minimal and not interpreted to be adverse. CONCLUSION: The proposed novel composite materials revealed that not only do these materials demonstrate high biocompatibility, but also their successful integration in the alveolus is likely secondary to a partial ligamentous attachment. The current investigation may lead to the use of calcium silicate-based materials as custom dental implants. Further research on this novel composite's biomechanical properties is necessary to develop the optimal material composition for use as a load-bearing dental implant.


Assuntos
Compostos de Cálcio/química , Implantes Dentários , Dentina/química , Cimento de Silicato , Silicatos/química , Alvéolo Dental/cirurgia , Animais , Fenômenos Biomecânicos , Cães , Imageamento Tridimensional , Inflamação , Masculino , Osseointegração , Ligamento Periodontal , Projetos Piloto , Extração Dentária , Alvéolo Dental/patologia , Microtomografia por Raio-X
2.
Int J Mol Sci ; 22(16)2021 Aug 18.
Artigo em Inglês | MEDLINE | ID: mdl-34445609

RESUMO

Respiratory disease is the leading cause of death in children under the age of 5 years old. Currently available treatments for paediatric respiratory diseases including bronchopulmonary dysplasia, asthma, cystic fibrosis and interstitial lung disease may ameliorate symptoms but do not offer a cure. Cellular therapy may offer a potential cure for these diseases, preventing disease progression into adulthood. Induced pluripotent stem cells, mesenchymal stromal cells and their secretome have shown great potential in preclinical models of lung disease, targeting the major pathological features of the disease. Current research and clinical trials are focused on the adult population. For cellular therapies to progress from preclinical studies to use in the clinic, optimal cell type dosage and delivery methods need to be established and confirmed. Direct delivery of these therapies to the lung as aerosols would allow for lower doses with a higher target efficiency whilst avoiding potential effect of systemic delivery. There is a clear need for research to progress into the clinic for the treatment of paediatric respiratory disease. Whilst research in the adult population forms a basis for the paediatric population, varying disease pathology and anatomical differences in paediatric patients means a paediatric-centric approach must be taken.


Assuntos
Terapia Baseada em Transplante de Células e Tecidos/métodos , Doenças Respiratórias/terapia , Criança , Humanos , Doenças Respiratórias/patologia
3.
Gastrointest Endosc ; 91(3): 663-668, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31756315

RESUMO

BACKGROUND AND AIMS: Endocuff improves detection at colonoscopy but seems to impede terminal ileal (TI) intubation. We assessed the impact of Endocuff Vision (EV) on TI intubation using adult or pediatric colonoscopes and evaluated whether filling the cecum with gas versus water affected the impact of EV on TI intubation. METHODS: Using a prospectively recorded quality control database, we explored the impact of EV on TI intubation in ≤1 minute. We used adult and pediatric colonoscopes and tested the effect of filling the cecum with gas versus water. If the initial attempt failed, then the alternative (water vs gas) was tried as a rescue method. RESULTS: TI intubation in ≤1 minute occurred in 91% of colonoscopies without EV versus 65% with EV, but the use of the pediatric colonoscope with EV had a higher success rate for TI intubation in ≤1 minute compared with the adult colonoscope with EV (73% vs 57%, P = .043). TI intubation in ≤1 minute was more successful with EV when the cecum was filled with water rather than gas (74% vs 56%, P = .019), but the benefit of water filling was limited to the adult colonoscope with EV. When EV was in place, water filling was more successful as a rescue method of TI intubation (58% vs 21%, P = .011). CONCLUSIONS: EV adversely affects TI intubation, particularly for adult colonoscopes. Water filling of the cecum mitigates the impact of EV on TI intubation with adult colonoscopes.


Assuntos
Ceco/cirurgia , Colonoscópios , Colonoscopia , Idoso , Competência Clínica , Colonoscópios/efeitos adversos , Colonoscopia/efeitos adversos , Colonoscopia/instrumentação , Colonoscopia/métodos , Colonoscopia/normas , Desenho de Equipamento , Feminino , Gases , Humanos , Íleo/cirurgia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fatores de Tempo , Água
4.
Gastrointest Endosc ; 91(1): 115-120, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31299257

RESUMO

BACKGROUND AND AIMS: Devices for flattening colon folds can improve polyp detection at colonoscopy. However, there are few data on the endoscopic ring-fitted cap (EndoRings; EndoAid, Caesarea, Israel). We sought to compare adenoma detection with EndoRings with that of standard high-definition colonoscopy. METHODS: This was a single-center, randomized controlled trial of 562 patients (284 randomized to EndoRings and 278 to standard colonoscopy) at 2 outpatient endoscopy units in the Indiana University Hospital system. Adenoma detection was the primary outcome measured as adenoma detection rate (ADR) and adenomas per colonoscopy (APC). We also compared sessile serrated polyp detection rate, insertion times, withdrawal times, and ease of passage through the sigmoid colon. RESULTS: EndoRings was superior to standard colonoscopy in terms of APC (1.46 vs 1.06, P = .025), but there were no statistically significant differences in ADR or sessile serrated polyp detection rate. Mean withdrawal time (in patients with no polyps) was shorter and insertion time (all patients) was longer in the EndoRings arm by 1.8 minutes and 0.75 minutes, respectively. One provider had significantly higher detection with Endo-Rings and contributed substantially to the overall results. CONCLUSIONS: EndoRings can increase adenoma detection without a significant increase in procedure time, but the effect varies between operators. The use of EndoRings slows colonoscope insertion. (Clinical trial registration number: NCT03418662.).


Assuntos
Adenoma/diagnóstico por imagem , Neoplasias do Colo/diagnóstico por imagem , Pólipos do Colo/diagnóstico por imagem , Colonoscopia/instrumentação , Adenoma/patologia , Idoso , Neoplasias do Colo/patologia , Pólipos do Colo/patologia , Colonoscópios , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia
5.
J Phys Chem A ; 124(20): 4128-4140, 2020 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-32227907

RESUMO

Ion-π interactions between the face of a molecular π-system and a cation or anion are among the strongest noncovalent interactions known, with applications throughout biochemistry and structural biology, molecular recognition and host-guest chemistry, as well as enzyme kinetics and organocatalysis. In this work, we examine the competing notions of selectivity and flexibility in this class of noncovalent interactions by investigating how certain π-systems can be promiscuous ion-π binders with the versatility to form favorable cation- and anion-π complexes. We focus our efforts on a detailed theoretical case study of the DNA/RNA nucleobases by first demonstrating that these π-systems are promiscuous ion-π binders with the biologically relevant Li+/Na+ cations and F-/Cl- anions via benchmark-quality quantum-mechanical binding energy curves computed at the CCSD(T)/CBS level of theory. Using a symmetry-adapted perturbation theory (SAPT)-based energy decomposition analysis, we explore the different physicochemical driving forces underlying the formation of cation- and anion-π complexes, as well as the crucial role played by charge penetration effects in determining the nontrivial (and often counterintuitive) electrostatics in anion-π systems. In doing so, a unified view of these rather distinct noncovalent binding motifs emerges with the finding that both cation- and anion-π complexes are strongly stabilized by an essentially ring-independent potential that can only be overcome by substantially unfavorable electrostatics. This work furnishes a more comprehensive explanation for decades of observed correlations between the equilibrium binding energy and the electrostatic potential above the ring and provides new insight into the nature of selectivity and flexibility in this important class of noncovalent interactions. Quite interestingly, the analysis presented herein demonstrates that π-systems have an inherent propensity to bind both cations and anions, thereby implying that promiscuous ion-π binding is not an exotic property of the nucleobases and should be common in nature.

6.
Nano Lett ; 19(8): 5818-5826, 2019 08 14.
Artigo em Inglês | MEDLINE | ID: mdl-31361503

RESUMO

Polymer-based electronics with low bending stiffnesses and high flexibility, including recently reported macroporous syringe-injectable mesh electronics, have shown substantial promise for chronic studies of neural circuitry in the brains of live animals. A central challenge for exploiting these highly flexible materials for in vivo studies has centered on the development of efficient input/output (I/O) connections to an external interface with high yield, low bonding resistance, and long-term stability. Here we report a new paradigm applied to the challenging case of injectable mesh electronics that exploits the high flexibility of nanoscale thickness two-sided metal I/O pads that can deform and contact standard interface cables in high yield with long-term electrical stability. First, we describe the design and facile fabrication of two-sided metal I/O pads that allow for contact without regard to probe orientation. Second, systematic studies of the contact resistance as a function of I/O pad design and mechanical properties demonstrate the key role of the I/O pad bending stiffness in achieving low-resistance stable contacts. Additionally, computational studies provide design rules for achieving high-yield multiplexed contact interfacing in the case of angular misalignment such that adjacent channels are not shorted. Third, the in vitro measurement of 32-channel mesh electronics probes bonded to interface cables using the direct contact method shows a reproducibly high yield of electrical connectivity. Finally, in vivo experiments with 32-channel mesh electronics probes implanted in live mice demonstrate the chronic stability of the direct contact interface, enabling consistent tracking of single-unit neural activity over at least 2 months without a loss of channel recording. The direct contact interfacing methodology paves the way for scalable long-term connections of multiplexed mesh electronics neural probes for neural recording and modulation and moreover could be used to facilitate a scalable interconnection of other flexible electronics in biological studies and therapeutic applications.


Assuntos
Eletrônica Médica/instrumentação , Animais , Eletrodos Implantados , Desenho de Equipamento , Injeções , Camundongos , Maleabilidade , Seringas
7.
Gastrointest Endosc ; 89(3): 591-598, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30367879

RESUMO

BACKGROUND AND AIMS: Although water exchange may improve adenoma detection compared with CO2, it is unclear whether water is a better medium to fill the lumen during withdrawal and visualize the mucosa. Total underwater colonoscopy (TUC) involves the use of water exchange with the air valve off during insertion followed by the inspection of the mucosa under water. Our goal was to compare miss rates for TUC with standard CO2 for polyps and adenomas using a tandem colonoscopy design. METHODS: We randomized participants to undergo tandem colonoscopies using TUC or CO2 first. In TUC, water exchange was performed during insertion, and withdrawal was performed under water. For the CO2 colonoscopy, both insertion and withdrawal were performed with CO2. The main outcomes were miss rates for polyps and adenomas for the first examination calculated as the number of additional polyps/adenomas detected during the second examination divided by the total number of polyps/adenomas detected for both examinations. Inspection times were calculated by subtracting the time for polypectomy, and care was taken to keep the times equal for both examinations. RESULTS: A total of 121 participants were randomized with 61 having CO2 first. The overall miss rate for polyps was higher for the TUC-first group (81/237; 34%) compared with the CO2-first cohort (57/264; 22%) (P = .002). In addition, the overall miss rate for all adenomas was higher for the TUC-first group (52/146; 36%) compared with the CO2 group (37/159; 23%) (P = .025). However, 1 of the 3 endoscopists had higher polyp/adenoma miss rates for CO2, but these were not statistically significant differences. The insertion time was longer for TUC than for CO2. After adjusting for times, participant characteristics, and bowel preparation, the miss rate for polyps was higher for TUC than for CO2. CONCLUSIONS: We found that TUC had an overall higher polyp and adenoma miss rate than colonoscopy performed with CO2, and TUC took longer to perform. However, TUC may benefit some endoscopists, an issue that requires further study. (Clinical trial registration number: NCT03231917.).


Assuntos
Adenoma/diagnóstico , Dióxido de Carbono , Pólipos do Colo/diagnóstico , Colonoscopia/métodos , Neoplasias Colorretais/diagnóstico , Erros de Diagnóstico/estatística & dados numéricos , Água , Idoso , Feminino , Humanos , Insuflação , Masculino , Pessoa de Meia-Idade
8.
Gastrointest Endosc ; 90(5): 835-840.e1, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31319060

RESUMO

BACKGROUND AND AIMS: Endocuff (Arc Medical Design, Leeds, UK) and Endocuff Vision (Arc Medical Design, Leeds, UK) are effective mucosal exposure devices for improving polyp detection during colonoscopy. AmplifEYE (Medivators Inc, Minneapolis, Minn, USA) is a device that appears similar to the Endocuff devices but has received minimal clinical testing. METHODS: We performed a randomized controlled clinical trial using a noninferiority design to compare Endocuff Vision with AmplifEYE. RESULTS: The primary endpoint of adenomas per colonoscopy was similar in AmplifEYE at 1.63 (standard deviation 2.83) versus 1.51 (2.29) with Endocuff Vision (P = .535). The 95% lower confidence limit was 0.88 for ratio of means, establishing noninferiority of AmplifEYE (P = .008). There was no difference between the arms for mean insertion time, and mean inspection time (withdrawal time minus polypectomy time and time for washing and suctioning) was shorter with AmplifEYE (6.8 minutes vs 6.9 minutes, P = .042). CONCLUSIONS: AmplifEYE is noninferior to Endocuff Vision for adenoma detection. The decision on which device to use can be based on cost. Additional comparisons of AmplifEYE with Endocuff by other investigators are warranted. (Clinical trial registration number: NCT03560128.).


Assuntos
Adenoma/diagnóstico por imagem , Neoplasias do Colo/diagnóstico por imagem , Colonoscopia/instrumentação , Idoso , Detecção Precoce de Câncer , Feminino , Humanos , Mucosa Intestinal/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia
9.
Gastrointest Endosc ; 90(5): 807-812, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31288028

RESUMO

BACKGROUND AND AIMS: Viscous solutions provide a superior submucosal cushion for EMR. SIC-8000 (Eleview; Aries Pharmaceuticals, La Jolla, Calif) is a commercially available U.S. Food and Drug Administration-approved solution, but hetastarch is also advocated. We performed a randomized trial comparing SIC-8000 with hetastarch as submucosal injection agents for colorectal EMR. METHODS: This was a single-center, double-blinded, randomized controlled trial performed at a tertiary referral center. Patients were referred to our center with flat or sessile lesions measuring ≥15 mm in size. The primary outcome measures were the Sydney resection quotient (SRQ) and the rate of en bloc resections. Secondary outcomes were total volume needed for a sufficient lift, number of resected pieces, and adverse events. RESULTS: There were 158 patients with 159 adenomas (SIC-8000, 84; hetastarch, 75) and 57 serrated lesions (SIC-8000, 30; hetastarch, 27). SRQ was significantly better in the SIC-8000 group compared with hetastarch group (9.3 vs 8.1, P = .001). There was no difference in the proportion of lesions with en bloc resections. The total volume of injectate was significantly lower with SIC-8000 (14.8 mL vs 20.6 mL, P = .038). CONCLUSIONS: SIC-8000 is superior to hetastarch for use during EMR in terms of SRQ and total volume needed, although the absolute differences were small. (Clinical trial registration number: NCT03350217.).


Assuntos
Adenoma/cirurgia , Neoplasias do Colo/cirurgia , Ressecção Endoscópica de Mucosa , Derivados de Hidroxietil Amido/administração & dosagem , Mucosa Intestinal/cirurgia , Poloxâmero/administração & dosagem , Idoso , Feminino , Humanos , Injeções , Masculino , Pessoa de Meia-Idade , Soluções Farmacêuticas/administração & dosagem
10.
Endoscopy ; 51(3): 221-226, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30722072

RESUMO

BACKGROUND: Diminutive colorectal polyps resected during colonoscopy are sometimes histologically interpreted as normal tissue. The aim of this observational study was to explore whether errors in specimen handling or processing account in part for polyps ≤ 3 mm in size being interpreted as normal tissue by pathology when they were considered high confidence adenomas by an experienced endoscopist at colonoscopy. METHODS: One endoscopist photographed 900 consecutive colorectal lesions that were ≤ 3 mm in size and considered endoscopically to be high confidence conventional adenomas. The photographs were reviewed blindly to eliminate poor quality images. The remaining 644 endoscopy images were reviewed by two external experts who predicted the histology while blinded to the pathology results. RESULTS: Of 644 consecutive lesions ≤ 3 mm in size considered high confidence conventional adenomas by a single experienced colonoscopist, 15.4 % were reported as normal mucosa by pathology. The prevalence of reports of normal mucosa in polyps removed by cold snare and cold forceps were 15.2 % and 16.0 %, respectively. When endoscopy photographs were reviewed by two blinded outside experts, the lesions found pathologically to be adenomas and normal mucosa were interpreted as high confidence adenomas by endoscopic appearance in 96.9 % and 93.9 %, respectively, by Expert 1 (P = 0.15), and in 99.6 % and 100 %, respectively, by Expert 2 (P = 0.51). CONCLUSION: Retrieval and/or processing of tissue specimens of tiny colorectal polyps resulted in some lesions being diagnosed as normal tissue by pathology despite being considered endoscopically to be high confidence adenomas. These findings suggest that pathology interpretation is not a gold standard for lesion management when this phenomenon is observed.


Assuntos
Adenoma/patologia , Competência Clínica , Pólipos do Colo/patologia , Colonoscopia/métodos , Neoplasias Colorretais/patologia , Erros de Diagnóstico/estatística & dados numéricos , Adenoma/cirurgia , Biópsia , Pólipos do Colo/cirurgia , Neoplasias Colorretais/cirurgia , Diagnóstico Diferencial , Humanos , Fotografação , Manejo de Espécimes
11.
J Allergy Clin Immunol ; 141(1): 235-249.e8, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-28219704

RESUMO

BACKGROUND: ß-Lactam hypersensitivity has been classified according to the phenotype and function of drug-specific T cells. However, new T-cell subsets have not been considered. OBJECTIVE: The objective of this study was to use piperacillin as a model of ß-lactam hypersensitivity to study the nature of the drug-specific T-cell response induced in the blood and skin of hypersensitive patients and healthy volunteers. METHODS: Drug-specific T cells were cloned from blood and inflamed skin, and cellular phenotype and function were explored. Naive T cells from healthy volunteers were primed to piperacillin, cloned, and subjected to the similar analyses. RESULTS: PBMC and T-cell clones (n = 570, 84% CD4+) from blood of piperacillin-hypersensitive patients proliferated and secreted TH1/TH2 cytokines alongside IL-22 after drug stimulation. IL-17A secretion was not detected. Drug-specific clones from inflamed skin (n = 96, 83% CD4+) secreted a similar profile of cytokines but displayed greater cytolytic activity, secreting perforin, granzyme B, and Fas ligand when activated. Blood- and skin-derived clones expressed high levels of skin-homing chemokine receptors and migrated in the presence of the ligands CCL17 and CCL27. Piperacillin-primed naive T cells from healthy volunteers also secreted IFN-γ, IL-13, IL-22, and cytolytic molecules. Aryl hydrocarbon receptor blockade prevented differentiation of the naive T cells into antigen-specific IL-22-secreting cells. CONCLUSION: Together, our results reveal that circulating and skin-resident, antigen-specific, IL-22-secreting T cells are detectable in patients with ß-lactam hypersensitivity. Furthermore, differentiation of naive T cells into antigen-specific TH22 cells is dependent on aryl hydrocarbon receptor signaling.


Assuntos
Hipersensibilidade a Drogas/sangue , Hipersensibilidade a Drogas/imunologia , Contagem de Linfócitos , Pele/citologia , Pele/imunologia , Linfócitos T Auxiliares-Indutores/imunologia , beta-Lactamas/efeitos adversos , Antígenos/imunologia , Citocinas/metabolismo , Humanos , Leucócitos Mononucleares/imunologia , Leucócitos Mononucleares/metabolismo , Ativação Linfocitária/imunologia , Piperacilina/efeitos adversos , Transdução de Sinais , Especificidade do Receptor de Antígeno de Linfócitos T , Subpopulações de Linfócitos T/imunologia , Subpopulações de Linfócitos T/metabolismo , Linfócitos T Auxiliares-Indutores/metabolismo
12.
Glob Chang Biol ; 24(9): 4293-4303, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29758588

RESUMO

Analysis of growth and biomass turnover in natural forests of Eucalyptus regnans, the world's tallest angiosperm, reveals it is also the world's most productive forest type, with fire disturbance an important mediator of net primary productivity (NPP). A comprehensive empirical database was used to calculate the averaged temporal pattern of NPP from regeneration to 250 years age. NPP peaks at 23.1 ± 3.8 (95% interquantile range) Mg C ha-1  year-1 at age 14 years, and declines gradually to about 9.2 ± 0.8 Mg C ha-1  year-1 at 130 years, with an average NPP over 250 years of 11.4 ± 1.1 Mg C ha-1  year-1 , a value similar to the most productive temperate and tropical forests around the world. We then applied the age-class distribution of E. regnans resulting from relatively recent historical fires to estimate current NPP for the forest estate. Values of NPP were 40% higher (13 Mg C ha-1  year-1 ) than if forests were assumed to be at maturity (9.2 Mg C ha-1  year-1 ). The empirically derived NPP time series for the E. regnans estate was then compared against predictions from 21 global circulation models, showing that none of them had the capacity to simulate a post-disturbance peak in NPP, as found in E. regnans. The potential importance of disturbance impacts on NPP was further tested by applying a similar approach to the temperate forests of conterminous United States and of China. Allowing for the effects of disturbance, NPP summed across both regions was on average 11% (or 194 Tg C/year) greater than if all forests were assumed to be in a mature state. The results illustrate the importance of accounting for past disturbance history and growth stage when estimating forest primary productivity, with implications for carbon balance modelling at local to global scales.


Assuntos
Ciclo do Carbono , Eucalyptus/fisiologia , Florestas , Árvores/crescimento & desenvolvimento , Austrália , China , Eucalyptus/crescimento & desenvolvimento , Estados Unidos
13.
Gastrointest Endosc ; 88(2): 335-344.e2, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29530353

RESUMO

BACKGROUND AND AIMS: Devices used to improve polyp detection during colonoscopy have seldom been compared with each other. METHODS: We performed a 3-center prospective randomized trial comparing high-definition (HD) forward-viewing colonoscopy alone to HD with Endocuff to HD with EndoRings to the full spectrum endoscopy (FUSE) system. Patients were age ≥50 years and had routine indications and intact colons. The study colonoscopists were all proven high-level detectors. The primary endpoint was adenomas per colonoscopy (APC). RESULTS: Among 1188 patients who completed the study, APC with Endocuff (APC mean ± standard deviation: 1.82 ± 2.58), EndoRings (1.55 ± 2.42), and standard HD colonoscopy (1.53 ± 2.33) were all higher than FUSE (1.30 ± 1.96; P < .001 for APC). The APC for Endocuff was higher than standard HD colonoscopy (P = .014). Mean cecal insertion times with FUSE (468 ± 311 seconds) and EndoRings (403 ± 263 seconds) were both longer than with Endocuff (354 ± 216 seconds; P = .006 and .018, respectively). CONCLUSIONS: For high-level detectors at colonoscopy, forward-viewing HD instruments dominate the FUSE system, indicating that for these examiners image resolution trumps angle of view. Further, Endocuff is a dominant strategy over EndoRings and no mucosal exposure device on a forward-viewing HD colonoscope. (Clinical trial registration number: NCT02345889.).


Assuntos
Adenoma/diagnóstico por imagem , Pólipos do Colo/diagnóstico por imagem , Colonoscopia/instrumentação , Neoplasias Colorretais/diagnóstico por imagem , Idoso , Ceco , Feminino , Humanos , Intubação , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fatores de Tempo
14.
J Immunol ; 192(6): 2611-2621, 2014 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-24510967

RESUMO

Activation of PD-1 on T cells is thought to inhibit Ag-specific T cell priming and regulate T cell differentiation. Thus, we sought to measure the drug-specific activation of naive T cells after perturbation of PD-L1/2/PD-1 binding and investigate whether PD-1 signaling influences the differentiation of T cells. Priming of naive CD4(+) and CD8(+) T cells against drug Ags was found to be more effective when PD-L1 signaling was blocked. Upon restimulation, T cells proliferated more vigorously and secreted increased levels of IFN-γ, IL-13, and IL-22 but not IL-17. Naive T cells expressed low levels of PD-1; however, a transient increase in PD-1 expression was observed during drug-specific T cell priming. Next, drug-specific responses from in vitro primed T cell clones and clones from hypersensitive patients were measured and correlated with PD-1 expression. All clones were found to secrete IFN-γ, IL-5, and IL-13. More detailed analysis revealed two different cytokine signatures. Clones secreted either FasL/IL-22 or granzyme B. The FasL/IL-22-secreting clones expressed the skin-homing receptors CCR4, CCR10, and CLA and migrated in response to CCL17/CCL27. PD-1 was stably expressed at different levels on clones; however, PD-1 expression did not correlate with the strength of the Ag-specific proliferative response or the secretion of cytokines/cytolytic molecules. This study shows that PD-L1/PD-1 binding negatively regulates the priming of drug-specific T cells. ELISPOT analysis uncovered an Ag-specific FasL/IL-22-secreting T cell subset with skin-homing properties.


Assuntos
Linfócitos T CD4-Positivos/imunologia , Linfócitos T CD8-Positivos/imunologia , Receptor de Morte Celular Programada 1/imunologia , Adulto , Antibacterianos/imunologia , Antibacterianos/farmacologia , Antígeno B7-H1 , Linfócitos T CD4-Positivos/efeitos dos fármacos , Linfócitos T CD4-Positivos/metabolismo , Linfócitos T CD8-Positivos/efeitos dos fármacos , Linfócitos T CD8-Positivos/metabolismo , Células Cultivadas , Proteína Ligante Fas/imunologia , Proteína Ligante Fas/metabolismo , Feminino , Citometria de Fluxo , Floxacilina/imunologia , Floxacilina/farmacologia , Humanos , Interferon gama/imunologia , Interferon gama/metabolismo , Interleucina-13/imunologia , Interleucina-13/metabolismo , Interleucina-2/imunologia , Interleucina-2/metabolismo , Interleucina-5/imunologia , Interleucina-5/metabolismo , Interleucinas/imunologia , Interleucinas/metabolismo , Ativação Linfocitária/efeitos dos fármacos , Ativação Linfocitária/imunologia , Receptor de Morte Celular Programada 1/metabolismo , Ligação Proteica/efeitos dos fármacos , Ligação Proteica/imunologia , Sulfametoxazol/análogos & derivados , Sulfametoxazol/imunologia , Sulfametoxazol/farmacologia , Adulto Jovem , Interleucina 22
15.
Eur J Pharm Sci ; 196: 106734, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38417586

RESUMO

Tuberculosis, caused by Mycobacterium tuberculosis (Mtb), is second only to COVID-19 as the top infectious disease killer worldwide. Multi-drug resistant TB (MDR-TB) may arise because of poor patient adherence to medications due to lengthy treatment duration and side effects. Delivering novel host directed therapies (HDT), like all trans retinoic acid (ATRA) may help to improve drug regimens and reduce the incidence of MDR-TB. Local delivery of ATRA to the site of infection leads to higher bioavailability and reduced systemic side effects. ATRA is poorly soluble in water and has a short half-life in plasma. Therefore, it requires a formulation step before it can be administered in vivo. ATRA loaded PLGA nanoparticles suitable for nebulization were manufactured and optimized using a scalable nanomanufacturing microfluidics (MF) mixing approach (MF-ATRA-PLGA NPs). MF-ATRA-PLGA NPs demonstrated a dose dependent inhibition of Mtb growth in TB-infected A549 alveolar epithelial cell model while preserving cell viability. The MF-ATRA-PLGA NPs were nebulized with the Aerogen Solo vibrating mesh nebulizer, with aerosol droplet size characterized using laser diffraction and the estimated delivered dose was determined. The volume median diameter (VMD) of the MF-ATRA-PLGA NPs was 3.00 ± 0.18 µm. The inhaled dose delivered in adult and paediatric 3D printed head models under a simulated normal adult and paediatric breathing pattern was found to be 47.05 ± 3 % and 20.15 ± 3.46 % respectively. These aerosol characteristics of MF-ATRA-PLGA NPs supports its suitability for delivery to the lungs via inhalation. The data generated on the efficacy of an inhalable, scalable and regulatory friendly ATRA-PLGA NPs formulation provides a foundation on which further pre-clinical testing can be built. Overall, the results of this project are promising for future research into ATRA loaded NPs formulations as inhaled host directed therapies for TB.

16.
Head Neck ; 46(2): 328-335, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38009416

RESUMO

BACKGROUND: Use of postoperative radiation therapy (PORT) in locoregionally advanced medullary thyroid cancer (MTC) remains controversial. The objective was to evaluate the effect of PORT on locoregional control (LRC) and overall survival (OS). METHODS: Retrospective cohort study of 346 MTC patients separated into PORT and no-PORT cohorts. Relative indications for PORT, as well as changes in patterns of treatment, were recorded. RESULTS: 49/346 (14%) received PORT. PORT was associated with worse OS; adjusted HR = 2.0 (95%CI 1.3-3.3). PORT was not associated with improved LRC, even when adjusting for advanced stage (Stage III p = 0.892; Stage IV p = 0.101). PORT and targeted therapy were not associated with improved OS compared to targeted therapy alone; adjusted HR = 1.2 (95%CI 0.3-4.1). CONCLUSIONS: Use of PORT in MTC has decreased and its indications have become more selective, coinciding with the advent of effective targeted therapies. Overall, PORT was not associated with improved LRC or OS.


Assuntos
Carcinoma Neuroendócrino , Neoplasias da Glândula Tireoide , Humanos , Estudos Retrospectivos , Neoplasias da Glândula Tireoide/radioterapia , Neoplasias da Glândula Tireoide/cirurgia , Carcinoma Neuroendócrino/radioterapia , Carcinoma Neuroendócrino/cirurgia , Estadiamento de Neoplasias , Radioterapia Adjuvante
17.
Nature ; 449(7162): 557-63, 2007 Oct 04.
Artigo em Inglês | MEDLINE | ID: mdl-17914389

RESUMO

Mesenchymal stem cells have been recently described to localize to breast carcinomas, where they integrate into the tumour-associated stroma. However, the involvement of mesenchymal stem cells (or their derivatives) in tumour pathophysiology has not been addressed. Here, we demonstrate that bone-marrow-derived human mesenchymal stem cells, when mixed with otherwise weakly metastatic human breast carcinoma cells, cause the cancer cells to increase their metastatic potency greatly when this cell mixture is introduced into a subcutaneous site and allowed to form a tumour xenograft. The breast cancer cells stimulate de novo secretion of the chemokine CCL5 (also called RANTES) from mesenchymal stem cells, which then acts in a paracrine fashion on the cancer cells to enhance their motility, invasion and metastasis. This enhanced metastatic ability is reversible and is dependent on CCL5 signalling through the chemokine receptor CCR5. Collectively, these data demonstrate that the tumour microenvironment facilitates metastatic spread by eliciting reversible changes in the phenotype of cancer cells.


Assuntos
Neoplasias da Mama/patologia , Células-Tronco Mesenquimais/patologia , Metástase Neoplásica , Células Estromais/patologia , Animais , Neoplasias da Mama/metabolismo , Carcinoma Ductal de Mama/metabolismo , Carcinoma Ductal de Mama/patologia , Linhagem Celular Tumoral , Movimento Celular , Quimiocina CCL5 , Quimiocinas CC/metabolismo , Fibroblastos/metabolismo , Fibroblastos/patologia , Humanos , Neoplasias Pulmonares/patologia , Neoplasias Pulmonares/secundário , Transplante de Células-Tronco Mesenquimais , Células-Tronco Mesenquimais/metabolismo , Camundongos , Camundongos Endogâmicos NOD , Camundongos SCID , Invasividade Neoplásica , Transplante de Neoplasias , Comunicação Parácrina , Receptores CCR5/metabolismo , Células Estromais/metabolismo
19.
J Mol Endocrinol ; 70(1)2023 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-36069797

RESUMO

Determination of the full-length thyroid-stimulating hormone receptor (TSHR) structure by cryo-electron microscopy (cryo-EM) is described. The TSHR complexed with human monoclonal TSHR autoantibody K1-70™ (a powerful inhibitor of TSH action) was detergent solubilised, purified to homogeneity and analysed by cryo-EM. The structure (global resolution 3.3 Å) is a monomer with all three domains visible: leucine-rich domain (LRD), hinge region (HR) and transmembrane domain (TMD). The TSHR extracellular domain (ECD, composed of the LRD and HR) is positioned on top of the TMD extracellular surface. Extensive interactions between the TMD and ECD are observed in the structure, and their analysis provides an explanation of the effects of various TSHR mutations on TSHR constitutive activity and on ligand-induced activation. K1-70™ is seen to be well clear of the lipid bilayer. However, superimposition of M22™ (a human monoclonal TSHR autoantibody which is a powerful stimulator of the TSHR) on the cryo-EM structure shows that it would clash with the bilayer unless the TSHR HR rotates upwards as part of the M22™ binding process. This rotation could have an important role in TSHR stimulation by M22™ and as such provides an explanation as to why K1-70™ blocks the binding of TSH and M22™ without activating the receptor itself.


Assuntos
Autoanticorpos , Receptores da Tireotropina , Humanos , Microscopia Crioeletrônica
20.
Transl Androl Urol ; 12(5): 690-699, 2023 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-37305636

RESUMO

Background: Penile prosthesis surgery (PPS) is a commonly used treatment for erectile dysfunction (ED), either as first-line therapy or in cases refractory to other treatment options. In patients with a urologic malignancy such as prostate cancer, surgical interventions like radical prostatectomy (RP) as well as non-surgical treatments such as radiation therapy can all induce ED. PPS as a treatment for ED has high satisfaction rates in the general population. Our aim was to compare sexual satisfaction in patients with prosthesis implantation for ED following RP versus ED following radiation therapy for prostate cancer. Methods: A retrospective chart review from our institutional database was conducted to identify patients who underwent PPS at our institution from 2011 to 2021. Erectile Dysfunction Inventory of Treatment Satisfaction (EDITS) questionnaire data at least 6 months from implant operative date available was required for inclusion. Eligible patients were placed in one of two groups depending on etiology of ED-following RP or prostate cancer radiation therapy. To prevent crossover confounding; patients with history of pelvic radiation were excluded from the RP group and patients with history of RP were excluded from the radiation group. Data were obtained from 51 patients in the RP group and 32 patients in the radiation therapy group. Mean EDITS scores and additional survey questions were compared between the radiation and RP groups. Results: There was a significant difference in mean survey responses for 8 of the 11 questions in the EDITS questionnaire between the RP group and the radiation group. Additional survey questions administered also found RP patients reported significantly higher rate of satisfaction with size of penis post-operatively versus the radiation group. Conclusions: These preliminary findings, while requiring large-scale follow-up, suggest that there is greater sexual satisfaction and penile prosthesis device satisfaction in patients undergoing IPP placement following RP versus radiation therapy for prostate cancer. Use of validated questionnaires should continue to be utilized in quantifying device and sexual satisfaction following PPS.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa