Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Malar J ; 21(1): 122, 2022 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-35413904

RESUMO

BACKGROUND: Microscopic examination of Giemsa-stained blood films remains the reference standard for malaria parasite detection and quantification, but is undermined by difficulties in ensuring high-quality manual reading and inter-reader reliability. Automated parasite detection and quantification may address this issue. METHODS: A multi-centre, observational study was conducted during 2018 and 2019 at 11 sites to assess the performance of the EasyScan Go, a microscopy device employing machine-learning-based image analysis. Sensitivity, specificity, accuracy of species detection and parasite density estimation were assessed with expert microscopy as the reference. Intra- and inter-device reliability of the device was also evaluated by comparing results from repeat reads on the same and two different devices. This study has been reported in accordance with the Standards for Reporting Diagnostic accuracy studies (STARD) checklist. RESULTS: In total, 2250 Giemsa-stained blood films were prepared and read independently by expert microscopists and the EasyScan Go device. The diagnostic sensitivity of EasyScan Go was 91.1% (95% CI 88.9-92.7), and specificity 75.6% (95% CI 73.1-78.0). With good quality slides sensitivity was similar (89.1%, 95%CI 86.2-91.5), but specificity increased to 85.1% (95%CI 82.6-87.4). Sensitivity increased with parasitaemia rising from 57% at < 200 parasite/µL, to ≥ 90% at > 200-200,000 parasite/µL. Species were identified accurately in 93% of Plasmodium falciparum samples (kappa = 0.76, 95% CI 0.69-0.83), and in 92% of Plasmodium vivax samples (kappa = 0.73, 95% CI 0.66-0.80). Parasite density estimates by the EasyScan Go were within ± 25% of the microscopic reference counts in 23% of slides. CONCLUSIONS: The performance of the EasyScan Go in parasite detection and species identification accuracy fulfil WHO-TDR Research Malaria Microscopy competence level 2 criteria. In terms of parasite quantification and false positive rate, it meets the level 4 WHO-TDR Research Malaria Microscopy criteria. All performance parameters were significantly affected by slide quality. Further software improvement is required to improve sensitivity at low parasitaemia and parasite density estimations. Trial registration ClinicalTrials.gov number NCT03512678.


Assuntos
Malária Falciparum , Malária , Testes Diagnósticos de Rotina/métodos , Humanos , Aprendizado de Máquina , Malária/diagnóstico , Malária/parasitologia , Malária Falciparum/parasitologia , Microscopia/métodos , Parasitemia/diagnóstico , Parasitemia/parasitologia , Plasmodium falciparum , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
2.
Emerg Infect Dis ; 27(7): 1991-1993, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-34152971

RESUMO

An HIV-positive man from Zimbabwe living in South Africa sought treatment for multiple clinical signs, including fever, weight loss, anemia, and splenomegaly. We identified in his blood an African rodent piroplasm, Anthemosoma garnhami, related to Babesia species. This finding extends the known geographic and host range of A. garnhami.


Assuntos
Babesia , Infecções por HIV , Piroplasmida , Humanos , África do Sul , Zimbábue
3.
Infect Dis Rep ; 7(1): 5726, 2015 Feb 24.
Artigo em Inglês | MEDLINE | ID: mdl-25874068

RESUMO

Humans are occasionally inadvertently infected with dirofilariae, the zoonotic nematodes. We report two cases of human dirofilariasis in South Africa, an area apparently non-endemic for this infection. Dirofilariasis is frequently misdiagnosed, so increased awareness of this entity in areas that are non-endemic is essential for prevention of inappropriate investigations and invasive therapy.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa