Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 514
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Vasc Med ; 29(2): 125-134, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38334067

RESUMO

BACKGROUND: Postacute sequelae of COVID-19 (PASC), also referred to as "Long COVID", sometimes follows COVID-19, a disease caused by SARS-CoV-2. Although SARS-CoV-2 is well known to promote a prothrombotic state, less is known about the thrombosis risk in PASC. Our objective was to evaluate platelet function and thrombotic potential in patients following recovery from SARS-CoV-2, but with clear symptoms of patients with PASC. METHODS: patients with PASC and matched healthy controls were enrolled in the study on average 15 months after documented SARS-CoV-2 infection. Platelet activation was evaluated by light transmission aggregometry (LTA) and flow cytometry in response to platelet surface receptor agonists. Thrombosis in platelet-deplete plasma was evaluated by Factor Xa activity. A microfluidics system assessed thrombosis in whole blood under shear stress conditions. RESULTS: A mild increase in platelet aggregation in patients with PASC through the thromboxane receptor was observed, and platelet activation through the glycoprotein VI (GPVI) receptor was decreased in patients with PASC compared to age- and sex-matched healthy controls. Thrombosis under shear conditions as well as Factor Xa activity were reduced in patients with PASC. Plasma from patients with PASC was an extremely potent activator of washed, healthy platelets - a phenomenon not observed when stimulating healthy platelets after incubation with plasma from healthy individuals. CONCLUSIONS: patients with PASC show dysregulated responses in platelets and coagulation in plasma, likely caused by a circulating molecule that promotes thrombosis. A hitherto undescribed protective response appears to exist in patients with PASC to counterbalance ongoing thrombosis that is common to SARS-CoV-2 infection.


Assuntos
COVID-19 , Trombose , Humanos , COVID-19/complicações , SARS-CoV-2 , Fator Xa , Coagulação Sanguínea , Progressão da Doença , Trombose/etiologia
2.
N Engl J Med ; 382(9): 799-809, 2020 02 27.
Artigo em Inglês | MEDLINE | ID: mdl-31995682

RESUMO

BACKGROUND: There are scant data on long-term clinical outcomes and bioprosthetic-valve function after transcatheter aortic-valve replacement (TAVR) as compared with surgical aortic-valve replacement in patients with severe aortic stenosis and intermediate surgical risk. METHODS: We enrolled 2032 intermediate-risk patients with severe, symptomatic aortic stenosis at 57 centers. Patients were stratified according to intended transfemoral or transthoracic access (76.3% and 23.7%, respectively) and were randomly assigned to undergo either TAVR or surgical replacement. Clinical, echocardiographic, and health-status outcomes were followed for 5 years. The primary end point was death from any cause or disabling stroke. RESULTS: At 5 years, there was no significant difference in the incidence of death from any cause or disabling stroke between the TAVR group and the surgery group (47.9% and 43.4%, respectively; hazard ratio, 1.09; 95% confidence interval [CI], 0.95 to 1.25; P = 0.21). Results were similar for the transfemoral-access cohort (44.5% and 42.0%, respectively; hazard ratio, 1.02; 95% CI, 0.87 to 1.20), but the incidence of death or disabling stroke was higher after TAVR than after surgery in the transthoracic-access cohort (59.3% vs. 48.3%; hazard ratio, 1.32; 95% CI, 1.02 to 1.71). At 5 years, more patients in the TAVR group than in the surgery group had at least mild paravalvular aortic regurgitation (33.3% vs. 6.3%). Repeat hospitalizations were more frequent after TAVR than after surgery (33.3% vs. 25.2%), as were aortic-valve reinterventions (3.2% vs. 0.8%). Improvement in health status at 5 years was similar for TAVR and surgery. CONCLUSIONS: Among patients with aortic stenosis who were at intermediate surgical risk, there was no significant difference in the incidence of death or disabling stroke at 5 years after TAVR as compared with surgical aortic-valve replacement. (Funded by Edwards Lifesciences; PARTNER 2 ClinicalTrials.gov number, NCT01314313.).


Assuntos
Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estudos de Coortes , Ecocardiografia , Feminino , Nível de Saúde , Humanos , Incidência , Análise de Intenção de Tratamento , Estimativa de Kaplan-Meier , Masculino , Análise Multivariada , Complicações Pós-Operatórias/mortalidade , Fatores de Risco , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Resultado do Tratamento
3.
J Thromb Thrombolysis ; 55(3): 426-431, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36653575

RESUMO

Vaccination against COVID-19 reduces infection-related mortality. Unfortunately, reports of vaccine-induced immune thrombotic thrombocytopenia (VITT) in individuals administered adenovirus-vector-based vaccines (ChAdOx1 nCoV-19 and Ad26.COV2.S) have spurred side effect concerns. To address vaccine hesitancy related to this, it is essential to determine the incidence of VITT (defined by a 50% decrease in platelet count and positive anti-PF4 immunoassay within 4-28 days after vaccination) among patients administered two doses of an mRNA-based COVID-19 vaccination. We identified a retrospective cohort of 223,345 patients in the Cleveland Clinic Enterprise administered a COVID-19 vaccine at any location in Northeast Ohio and Florida from 12/4/2020 to 6/6/2021. 97.3% of these patients received an mRNA-based vaccination. Patients with: (1) a serial complete blood count both before and after vaccination and (2) a decrease in platelet count of ≥ 50% were selected for chart review. The primary outcome was the incidence of thrombotic events, including venous thromboembolism (VTE) and arterial thrombosis, 4-28 days post vaccination. Of 74 cohort patients with acute thrombosis, 72 (97.3%) demonstrated clear etiologies, such as active malignancy. Of two patients with unprovoked thrombosis, only one had findings concerning for VITT, with a strongly positive anti-PF4 antibody assay. In this large, multi-state, retrospective cohort, of 223,345 patients (97.2% of whom received the mRNA-based mRNA-1273 or BNT162b2 vaccines), we detected a single case that was concerning for VITT in a patient who received an mRNA vaccine. The overwhelming majority of patients with a thrombotic event 4-28 days following vaccination demonstrated clear etiologies.


Assuntos
COVID-19 , Púrpura Trombocitopênica Idiopática , Trombocitopenia , Humanos , Vacinas contra COVID-19/efeitos adversos , Ad26COVS1 , Vacina BNT162 , ChAdOx1 nCoV-19 , Estudos Retrospectivos , COVID-19/prevenção & controle , Vacinação/efeitos adversos , Trombocitopenia/induzido quimicamente
4.
Echocardiography ; 40(4): 318-326, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36859633

RESUMO

BACKGROUND: The implications of left ventricular remodeling and dysfunction before and after aortic valve replacement (AVR) for mixed aortic valve disease (MAVD) are not well understood. This study aims to evaluate the impact of AVR on left ventricular (LV) systolic function in MAVD, and determine the prognostic value of postoperative LV global longitudinal strain (LV-GLS) and LV ejection fraction (LVEF). METHODS: We retrospectively assessed 489 consecutive patients with MAVD (defined as at least moderate aortic stenosis and at least moderate aortic regurgitation) and baseline LVEF ≥50%, who underwent AVR between February 2003 and August 2018. All patients had baseline echocardiography, whereas 192 patients underwent postoperative echocardiography between 3 and 18 months after AVR. The primary endpoint was all-cause mortality. RESULTS: Mean age was 65 ± 15 years, and 65% were male. AVR in MAVD patients has a neutral effect on LV systolic function quantitated by LVEF and LV-GLS. During a median follow-up period of 5.8 years, 65 patients (34%) of 192 patients with follow-up echocardiography died. The patients with postoperative LVEF ≥50% had better survival than those with postoperative LVEF <50% (P < .001). Furthermore, among patients with postoperative LVEF ≥50%, mortality differed between patients with postoperative LV-GLS worse than -15% and those with postoperative LV-GLS better than -15% (P < .001). CONCLUSIONS: In patients with MAVD who underwent AVR, the mean postoperative LV-GLS and LVEF remain at a similar value to baseline. However, worse postoperative LV-GLS and LVEF were both independently associated with higher mortality in this population.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Disfunção Ventricular Esquerda , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Feminino , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Prognóstico , Estudos Retrospectivos , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Disfunção Ventricular Esquerda/complicações , Disfunção Ventricular Esquerda/diagnóstico por imagem , Função Ventricular Esquerda , Volume Sistólico
5.
Catheter Cardiovasc Interv ; 99(1): 160-168, 2022 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-34184817

RESUMO

OBJECTIVES: This study sought to examine the association of hospital procedural volume with the incidence and outcomes of surgical bailout (SB) in patients who undergo transcatheter aortic valve replacement (TAVR). BACKGROUND: SB is required for serious complications during or after TAVR. It remains unclear whether hospital experiences affect the incidence and outcomes of SB. METHODS: We retrospectively identified patients who underwent endovascular TAVR using the Nationwide Readmissions Database 2012-2017. We examined the association of annual hospital procedural volume (annual number of endovascular TAVR cases in each hospital in each year) with the incidence and in-hospital mortality of SB using multivariable logistic regressions and restricted cubic splines. RESULTS: Among 82,764 eligible patients, the incidence of SB was 0.95% (n = 789) and decreased from 2012 to 2017 (from 2.66% to 0.49%; Ptrend < 0.001), while in-hospital mortality of SB remained high over years (from 26.0% to 23.5%; Ptrend  = 0.773). Very-high-volume hospitals (≥200 cases/year), as compared with low-volume hospitals (≤49 cases/year), showed significantly a lower incidence of SB (0.49% vs. 1.81%; adjusted OR = 0.28, 95% CI = 0.21-0.38), but similar in-hospital mortality of SB (26.2% vs. 25.6%; adjusted OR = 0.88, 95% CI = 0.47-1.66). There was a significant nonlinear, inverse association of hospital volume with the incidence of SB, but not with the in-hospital mortality of SB. CONCLUSIONS: Hospitals with higher TAVR volumes have a lower risk of SB, but the in-hospital mortality after SB does not change with hospital TAVR volume. Our findings highlight the importance that physicians should always be aware of the high mortality risk of SB following TAVR regardless of hospital procedural experiences.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Mortalidade Hospitalar , Hospitais com Baixo Volume de Atendimentos , Humanos , Incidência , Estudos Retrospectivos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
6.
Catheter Cardiovasc Interv ; 99(3): 877-888, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34236762

RESUMO

OBJECTIVES: This study aimed to evaluate the incidence, treatment, and outcomes of acute myocardial infarction (AMI) following transcatheter or surgical aortic valve replacement (TAVR or SAVR). BACKGROUND: Coronary artery disease is common in patients who undergo aortic valve replacement. However, little is known about differences in clinical features of post-TAVR or post-SAVR AMI. METHODS: We retrospectively identified post-TAVR or post-SAVR (including isolated and complex SAVR) patients admitted with AMI using the Nationwide Readmissions Database 2012-2017. Incidence, invasive strategy (coronary angiography or revascularization), and in-hospital outcomes were compared between post-TAVR and post-SAVR AMIs. RESULTS: The incidence of 180-day AMI was higher post-TAVR than post-SAVR (1.59% vs. 0.72%; p < 0.001). Post-TAVR AMI patients (n = 1315), compared with post-SAVR AMI patients (n = 1344), were older, had more comorbidities and more frequent non-ST-elevation AMI (NSTEMI: 86.6% vs. 78.0%; p < 0.001). After propensity-score matching, there was no significant difference in in-hospital mortality between post-TAVR and post-SAVR AMIs (14.7% vs. 16.1%; p = 0.531), but the mortality was high in both groups, particularly in ST-elevation AMI (STEMI: 38.8% vs. 29.2%; p = 0.153). Invasive strategy was used less frequently for post-TAVR AMI than post-SAVR AMI (25.6% vs. 38.3%; p < 0.001). Invasive strategy was associated with lower mortality in both post-TAVR (adjusted odds ratio = 0.40; 95% confidence interval = [0.24-0.66]) and post-SAVR groups (0.60 [0.41-0.88]). CONCLUSIONS: AMI, albeit uncommon, was more frequent post-TAVR than post-SAVR. Patients commonly presented with NSTEMI, but the mortality of STEMI was markedly high. Further studies are needed to understand why a substantial percentage of patients do not receive invasive coronary treatment, particularly after TAVR, despite seemingly better outcomes with invasive strategy.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Infarto do Miocárdio com Supradesnível do Segmento ST , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Mortalidade Hospitalar , Humanos , Incidência , Estudos Retrospectivos , Fatores de Risco , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico por imagem , Infarto do Miocárdio com Supradesnível do Segmento ST/epidemiologia , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
7.
Catheter Cardiovasc Interv ; 100(5): 860-867, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36116028

RESUMO

BACKGROUND: Transcatheter aortic valve-in-valve implantation (ViV-TAVI) has emerged in recent years as a safe alternative to redo surgery in high-risk patients. Although early results are encouraging, data beyond short-term outcomes are lacking. Herein, we aimed to assess the 2-year outcomes after ViV-TAVI. METHODS: Patients undergoing ViV-TAVI for degenerated surgical valves between 2013 and 2019 at the Cleveland Clinic were reviewed. The coprimary endpoints were all-cause mortality and congestive heart failure (CHF) hospitalizations. We used time-to-event analyses to assess the primary outcomes. Further, we measured the changes in transvalvular gradients and the incidence of structural valve deterioration (SVD). RESULTS: One hundred and eighty-eight patients were studied (mean age = 76 years; 65% males). At 2 years of follow-up, all-cause mortality and CHF hospitalizations occurred in 15 (8%) and 28 (14.9%) patients, respectively. On multivariable analysis, the postprocedural length of stay was a significant predictor for both all-cause mortality (hazard ratio [HR] = 1.1; 95% confidence interval [CI]: 1.01, 1.19) and CHF hospitalization (HR = 1.16; 95% CI: 1.07, 1.27). However, the internal diameter of the surgical valve was not associated with significant differences in both primary endpoints. For hemodynamic outcomes, nine patients (4.8%) developed SVD. The mean and peak transvalvular pressure gradients remained stable over the follow-up period. CONCLUSION: ViV-TAVI for degenerated surgical valves was associated with favorable 2-year clinical and hemodynamic outcomes. Further studies are needed to better understand the role of ViV-TAVI as a treatment option in the life management of aortic valve disease.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Masculino , Humanos , Idoso , Feminino , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Bioprótese/efeitos adversos , Falha de Prótese , Reoperação/métodos , Resultado do Tratamento , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Implante de Prótese de Valva Cardíaca/métodos
8.
J Cardiovasc Magn Reson ; 24(1): 12, 2022 02 22.
Artigo em Inglês | MEDLINE | ID: mdl-35193584

RESUMO

BACKGROUND: Significant aortic regurgitation (AR) leads to left ventricular (LV) remodeling; however, little data exist regarding sex-based differences in LV remodeling in this setting. We sought to compare LV remodeling and AR severity, assessed by echocardiography and cardiovascular magnetic resonance (CMR), to discern sex-based differences. METHODS: Patients with ≥ moderate chronic AR by echocardiography who underwent CMR within 90 days between December 2005 and October 2015 were included. Nonlinear regression models were built to assess the effect of AR regurgitant fraction (RF) on LV remodeling. A generalized linear model and Bland Altman analyses were constructed to evaluate differences between CMR and echocardiography. Referral for surgical intervention based on symptoms and LV remodeling was evaluated. RESULTS: Of the 243 patients (48.3 ± 16.6 years, 58 (24%) female), 119 (49%) underwent surgical intervention with a primary indication of severe AR, 97 (82%) men, 22 (18%) women. Significant sex differences in LV remodeling emerged on CMR. Women demonstrated significantly smaller LV end-diastolic volume index (LVEDVI) (96.8 ml/m2 vs 125.6 ml/m2, p < 0.001), LV end-systolic volume index (LVESVI) (41.1 vs 54.5 ml/m2, p < 0.001), blunted LV dilation in the setting of increasing AR severity (LVEDVI p value < 0.001, LVESVI p value 0.011), and LV length indexed (8.32 vs 9.69 cm, p < 0.001). On Bland Altman analysis, a significant interaction with sex and LV diameters was evident, demonstrating a significant increase in the difference between CMR and echocardiography measurements as the LV enlarged in women: LVEDVI (p = 0.006), LVESVI (p < 0.001), such that echocardiographic measurements increasingly underestimated LV diameters in women as the LV enlarged. LV length was higher for males with a linear effect from RF (p < 0.001), with LV length increasing at a higher rate with increasing RF for males compared to females (two-way interaction with sex p = 0.005). Sphericity volume index was higher for men after adjusting for a relative wall thickness (p = 0.033). CONCLUSIONS: CMR assessment of chronic AR revealed significant sex differences in LV remodeling and significant echocardiographic underestimation of LV dilation, particularly in women. Defining optimal sex-based CMR thresholds for surgical referral should be further developed. TRIAL REGISTRATION: NA.


Assuntos
Insuficiência da Valva Aórtica , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/cirurgia , Ecocardiografia , Feminino , Humanos , Masculino , Valor Preditivo dos Testes , Caracteres Sexuais , Função Ventricular Esquerda , Remodelação Ventricular
9.
Catheter Cardiovasc Interv ; 97(3): 477-485, 2021 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-32857915

RESUMO

OBJECTIVE: We aimed to compare short-term outcomes between transcatheter aortic valve replacement (TAVR) for pure aortic regurgitation (AR) and TAVR for aortic stenosis (AS). BACKGROUND: In patients with severe pure AR for whom surgical valve replacement is infeasible, TAVR is sometimes used off-label. METHODS: Using the Nationwide Readmissions Database 2016-2017, we retrospectively identified patients without prior valve surgery who underwent endovascular TAVR. We compared in-hospital and 30-day outcomes according to the type of aortic valve disease. RESULTS: A total of 81,542 eligible patients were divided into the pure AR (n = 1,222, 1.50%), pure AS (n = 72,690, 89.1%), and AS + AR (n = 7,630, 9.36%) groups. In unadjusted analyses, the pure AR group, compared with the pure AS and AS + AR groups, showed a higher incidence of acute kidney injury (16.8% vs. 9.8% vs. 12.1%, respectively; p < .001) and need of surgical bailout (1.4% vs. 0.4% vs. 0.6%; p < .01). The pure AR group also showed higher in-hospital mortality than the pure AS group (2.4% vs. 1.4%; p = .005). After multivariable adjustment, TAVR for pure AR was significantly associated with a higher risk of acute kidney injury (odds ratio [OR] = 1.64, 95% confidence interval [CI] = 1.33-2.02; p < .001), cardiac tamponade (OR = 1.98, 95% CI = 1.00-3.92; p = .0498), and prolonged hospital stay (OR = 1.59, 95% CI = 1.29-1.95; p < .001) compared with TAVR for pure AS, whereas it was not significantly associated with in-hospital mortality (OR = 1.55, 95% CI = 0.99-2.45; p = .058) and other outcomes. CONCLUSIONS: TAVR may be a reasonable treatment option for selected patients with pure AR with regard to short-term outcomes. However, additional techniques or devices may be necessary to reduce periprocedural risk.


Assuntos
Insuficiência da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/cirurgia , Humanos , Estudos Retrospectivos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Estados Unidos/epidemiologia
10.
Catheter Cardiovasc Interv ; 98(3): E436-E443, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33512085

RESUMO

BACKGROUND: Monitored anesthesia care (MAC) has become more widely used during transcatheter aortic valve replacement (TAVR) to avoid the complications of general anesthesia (GA). METHODS: We included consecutive patients who underwent transfemoral-TAVR at our institution between January 2012 and April 2017. We compared outcomes with GA versus MAC. RESULTS: Of 998 patients, MAC was used in 43.9%. MAC was associated with shorter procedural time (96.9 ± 30.9 vs. 135 ± 64.6 mins; p < .001), fluoroscopy time (20.4 ± 8.9 vs. 29 ± 18.7 mins; p < .001), lower contrast volume (45.5 ± 27 vs. 60.4 ± 43 cc; p < .001), and decreased radiation exposure (12,869 ± 8,099 vs. 20,630 ± 16,276 cGy-cm2 ; p < .001). Patients who underwent MAC had a briefer median (IQR) intensive care unit stay [23.3 (21-24) vs. 23.4 (20.8-26) hrs; p < .001], and hospital stay [2 (2, 3) vs. 3 (2-6) days; p < .001], and were more frequently discharged to home (93.4% vs. 82.9%; p < .001). MAC was associated with lower mortality at 30 days (0.5% vs. 2.9%; log-rank p = .012; adjHR 0.22, 95% CI 0.06-0.82; p = .024), but not at 1 year (11.7% vs. 14.6%; log-rank p = .157) or 3 years (36.8% vs. 38.4%; log-rank p = 0.433). There were no differences in major adverse cardiac and cerebrovascular events (MACCE) at either 30 days (4.6% vs. 9.3%; log-rank p = .14) or 1 year (21.1% vs. 21.5%; log-rank p = .653). Similar findings were seen among patients who received newer-generation SAPIEN-3 valves. CONCLUSION: Utilizing MAC and omitting intraprocedural transesophageal echocardiography during TAVR seems to be more efficient without compromising safety. Better TAVR outcomes can be achieved with newer generation valves without needing GA.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Anestesia Geral/efeitos adversos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Fluoroscopia , Humanos , Tempo de Internação , Estudos Retrospectivos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
11.
Catheter Cardiovasc Interv ; 97(3): 529-539, 2021 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-32845036

RESUMO

BACKGROUND: There is a paucity of data regarding the optimum timing of PCI in relation to TAVR. OBJECTIVE: We compared the major adverse cardiovascular and cerebrovascular events (MACCE) rates among patients who underwent percutaneous coronary intervention (PCI) before transcatheter aortic valve replacement (TAVR) with those who received PCI with/after TAVR. METHODS: In this multicenter study, we pooled all consecutive patients who underwent TAVR at three high volume centers. RESULTS: Among 3,982 patients who underwent TAVR, 327 (8%) patients underwent PCI within 1 year before TAVR, 38 (1%) had PCI the same day as TAVR and 15 (0.5%) had PCI within 2 months after TAVR. Overall, among patients who received both PCI and TAVR (n = 380), history of previous CABG (HR:0.501; p = .001), higher BMI at TAVR (HR:0.970; p = .038), and statin therapy after TAVR (HR:0.660, p = .037) were independently associated with lower MACCE while warfarin therapy after TAVR was associated with a higher risk of MACCE (HR:1.779, p = .017). Patients who received PCI within 1 year before TAVR had similar baseline demographics, STS scores, clinical risk factors when compared to patients receiving PCI with/after TAVR. Both groups were similar in PCI (Syntax Score, ACC/AHA lesion class) and TAVR (valve types, access) related variables. There were no significant differences in terms of MACCE (log rank p = .550), all-cause mortality (log rank p = .433), strokes (log rank p = .153), and repeat PCI (log rank p = .054) in patients who underwent PCI with/after TAVR when compared to patients who received PCI before TAVR. CONCLUSION: Among patients who underwent both PCI and TAVR, history of CABG, higher BMI, and statin therapy had lower, while those discharged on warfarin, had higher adverse event rates. Adverse events rates were similar regardless of timing of PCI.


Assuntos
Estenose da Valva Aórtica , Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Substituição da Valva Aórtica Transcateter , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Doença da Artéria Coronariana/cirurgia , Doença da Artéria Coronariana/terapia , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Sistema de Registros , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
12.
Vasc Med ; 26(6): 626-632, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34010070

RESUMO

Coronavirus disease 2019 (COVID-19) caused by SARS-CoV-2 is an ongoing viral pandemic marked by increased risk of thrombotic events. However, the role of platelets in the elevated observed thrombotic risk in COVID-19 and utility of antiplatelet agents in attenuating thrombosis is unknown. We aimed to determine if the antiplatelet effect of aspirin may mitigate risk of myocardial infarction, cerebrovascular accident, and venous thromboembolism in COVID-19. We evaluated 22,072 symptomatic patients tested for COVID-19. Propensity-matched analyses were performed to determine if treatment with aspirin or nonsteroidal anti-inflammatory drugs (NSAIDs) affected thrombotic outcomes in COVID-19. Neither aspirin nor NSAIDs affected mortality in COVID-19. Thus, aspirin does not appear to prevent thrombosis and death in COVID-19. The mechanisms of thrombosis in COVID-19, therefore, appear distinct and the role of platelets as direct mediators of SARS-CoV-2-mediated thrombosis warrants further investigation.


Assuntos
Anti-Inflamatórios não Esteroides/administração & dosagem , Aspirina/administração & dosagem , COVID-19/complicações , Pacientes Internados , Trombose/prevenção & controle , Adulto , Idoso , Anti-Inflamatórios não Esteroides/efeitos adversos , Aspirina/efeitos adversos , Feminino , Hospitalização , Humanos , Masculino , Pessoa de Meia-Idade , Pandemias , SARS-CoV-2 , Trombose/virologia
13.
Am Heart J ; 227: 91-99, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32693197

RESUMO

Vitamin K antagonists are the only approved oral anticoagulants for long-term prophylaxis against valve thrombosis and thromboembolism in patients with a mechanical heart valve. Despite the proven efficacy and safety of anticoagulation with the oral direct factor Xa inhibitor apixaban compared with warfarin in high-risk populations including subjects with atrial fibrillation or with venous thromboembolism, it remains unknown whether patients with a mechanical heart valve can be safely managed with apixaban. The On-X Aortic Heart Valve and On-X Ascending Aortic Prosthesis with the Vascutek Gelweave Valsalva Graft may have lower rates of valve thrombosis and thromboembolism than conventional bileaflet and tilting disc valves due its unique pyrolytic carbon composition and flared inlet design. DESIGN: PROACT Xa is a randomized, multicenter, open-label, active-controlled trial comparing apixaban with warfarin in patients with an On-X Aortic Heart Valve or On-X Ascending Aortic Prosthesis with the Vascutek Gelweave Valsalva Graft. The study will randomize approximately 1,000 patients from approximately 60 sites in North America who underwent aortic valve replacement at least 3 months prior. Patients will be randomized 1:1 to receiving apixaban 5 mg twice daily or warfarin with a target international normalized ratio of 2.0-3.0. The last randomized participant will be followed for at least 2 years. The primary efficacy outcome is the composite of valve thrombosis and valve-related thromboembolism, and the primary safety outcome is major bleeding. Assuming the primary outcome occurs in warfarin-anticoagulated patients at a rate of 1.75%/patient-year, the study has more than 90% power to assess noninferiority of apixaban treatment with an absolute noninferiority margin of 1.75%/patient-year. A second co-primary analysis is to compare the hazard rate for the apixaban arm to twice the objective performance criterion for thromboembolism and valve thrombosis, that is, 3.4%/patient-year. SUMMARY: PROACT Xa will determine whether patients with an On-X Aortic Heart Valve can be anticoagulated with apixaban as an alternative to warfarin.


Assuntos
Anticoagulantes/uso terapêutico , Valva Aórtica/cirurgia , Inibidores do Fator Xa/uso terapêutico , Próteses Valvulares Cardíacas , Complicações Pós-Operatórias/prevenção & controle , Pirazóis/uso terapêutico , Piridonas/uso terapêutico , Ensaios Clínicos Controlados Aleatórios como Assunto/métodos , Tromboembolia/prevenção & controle , Trombose/prevenção & controle , Varfarina/uso terapêutico , Anticoagulantes/efeitos adversos , Inibidores do Fator Xa/efeitos adversos , Humanos , Estudos Multicêntricos como Assunto , Desenho de Prótese , Pirazóis/efeitos adversos , Piridonas/efeitos adversos , Resultado do Tratamento , Varfarina/efeitos adversos
14.
Curr Opin Cardiol ; 35(6): 679-686, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-33002935

RESUMO

PURPOSE OF REVIEW: Perioperative stroke remains one of the most dreaded complications following coronary artery bypass grafting. In this review, we highlight the significant advances in understanding and preventing stroke in patients undergoing bypass surgery and offer our center's current best-practice recommendations to help avoid this debilitating outcome. RECENT FINDINGS: The incidence of stroke has significantly reduced since the advent of coronary artery bypass graft surgery. Improvements in our understanding of the cause, mechanisms, risk factors, and diagnosis of stroke as well as refinements in medical optimization, surgical technique, and perioperative care all have contributed to making coronary artery bypass grafting safer even as patients have become increasingly complex. SUMMARY: The field of cardiothoracic surgery endures in its quest to eliminate the risk of perioperative stroke. By incorporating the lessons of the past into our innovations of the future, cardiac surgeons will continue to strive for safer coronary artery bypass grafting and afford patients to not only live longer but better as well.


Assuntos
Doença da Artéria Coronariana , Acidente Vascular Cerebral , Ponte de Artéria Coronária , Humanos , Incidência , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/prevenção & controle , Fatores de Risco , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Resultado do Tratamento
15.
J Surg Res ; 254: 1-6, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32388058

RESUMO

BACKGROUND: Little is known about graft patency after coronary artery bypass grafting (CABG) performed in patients on dialysis. Our aim was to assess patency of internal thoracic artery (ITA) grafts and saphenous vein grafts (SVGs) in these patients. METHODS: From 1/1997 to 1/2018, 500 patients on dialysis underwent primary CABG with or without concomitant procedures at Cleveland Clinic, 40 of whom had 48 postoperative angiograms for recurrent ischemic symptoms. Complete follow-up was obtained on all but 1 patient lost to follow-up 1 y after CABG. Thirty-six ITA grafts and 65 SVGs were evaluable for stenosis and occlusion. RESULTS: Two of 40 patients (5%) had emergency CABG; 3 (7.5%) with calcified aortas had a change in operative strategy to avoid ascending aortic manipulation, 2 (5%) had poor conduit quality, and 12 (30%) had severe diffuse atherosclerotic disease with calcification of the coronary targets causing technical difficulties. Thirty-three patients (82%) were bypassed with an in situ ITA and 3 (7.5%) had a free ITA graft. Three of 36 ITA grafts were occluded at 0.78, 1.8, and 9.4 y (too few to model). SVG patency was 52% and 37% at 1 and 2 y, respectively. CONCLUSIONS: Among patients on dialysis who underwent CABG, coronary angiography for ischemic symptoms in a select subset revealed that SVG patency was lower than expected from published reports in the general CABG population and may contribute to the poor prognosis of this cohort. Further work is needed to guide graft selection and improve graft patency in dialysis patients.


Assuntos
Ponte de Artéria Coronária , Doença das Coronárias/cirurgia , Sobrevivência de Enxerto , Falência Renal Crônica/complicações , Diálise Renal , Grau de Desobstrução Vascular , Idoso , Doença das Coronárias/complicações , Doença das Coronárias/mortalidade , Feminino , Humanos , Falência Renal Crônica/terapia , Masculino , Artéria Torácica Interna/transplante , Pessoa de Meia-Idade , Veia Safena/transplante , Resultado do Tratamento
16.
J Card Surg ; 35(10): 2506-2511, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33043652

RESUMO

BACKGROUND: Cardiac surgery accounts for 10-15% of blood transfusions in the US, despite benefits and calls of limiting its use. We sought to evaluate the impact of a restrictive transfusion protocol on blood use and clinical outcomes in patients undergoing isolated primary coronary artery bypass grafting (CABG). METHODS: Blood conservation measures, instituted in 2012, include preoperative optimization, intraoperative anesthesia, and pump fluid restriction with retrograde autologous priming and vacuum-assisted drainage, use of aminocaproic acid and cell saver, intra- and postoperative permissive anemia, and administration of iron and low-dose vasopressors if needed. Medical records of patients who underwent isolated primary CABG from 2009 to 2012 (group A; n = 375) and 2013 to 2016 (group B; n = 322) were compared. RESULTS: CABG with grafting to three or four coronary arteries was performed in 262 (70%) and 222 (69%) patients and bilateral internal thoracic artery grafting in 202 (54%) and 196 (61%) patients in groups A and B, respectively. Mean preoperative and intraoperative hematocrit was 40.3% and 40.7%, 28.9% and 29.4% in groups A and B, respectively. Total blood transfusion was 24% and 6.5%, intraoperative transfusion 11% and 1.2%, and postoperative transfusion 20% and 5.6% (P < .0001 for all) in groups A and B, respectively. Median postoperative length of stay was 5.0 days in group A and 4.5 days in group B (P = .02), with no significant differences in mortality or morbidity. CONCLUSIONS: A restrictive transfusion protocol reduced blood transfusions and postoperative length of stay without adversely affecting outcomes following isolated primary CABG.


Assuntos
Transfusão de Sangue/estatística & dados numéricos , Ponte de Artéria Coronária/métodos , Tempo de Internação , Assistência Perioperatória/estatística & dados numéricos , Feminino , Humanos , Masculino , Resultado do Tratamento
17.
N Engl J Med ; 374(17): 1609-20, 2016 04 28.
Artigo em Inglês | MEDLINE | ID: mdl-27040324

RESUMO

BACKGROUND: Previous trials have shown that among high-risk patients with aortic stenosis, survival rates are similar with transcatheter aortic-valve replacement (TAVR) and surgical aortic-valve replacement. We evaluated the two procedures in a randomized trial involving intermediate-risk patients. METHODS: We randomly assigned 2032 intermediate-risk patients with severe aortic stenosis, at 57 centers, to undergo either TAVR or surgical replacement. The primary end point was death from any cause or disabling stroke at 2 years. The primary hypothesis was that TAVR would not be inferior to surgical replacement. Before randomization, patients were entered into one of two cohorts on the basis of clinical and imaging findings; 76.3% of the patients were included in the transfemoral-access cohort and 23.7% in the transthoracic-access cohort. RESULTS: The rate of death from any cause or disabling stroke was similar in the TAVR group and the surgery group (P=0.001 for noninferiority). At 2 years, the Kaplan-Meier event rates were 19.3% in the TAVR group and 21.1% in the surgery group (hazard ratio in the TAVR group, 0.89; 95% confidence interval [CI], 0.73 to 1.09; P=0.25). In the transfemoral-access cohort, TAVR resulted in a lower rate of death or disabling stroke than surgery (hazard ratio, 0.79; 95% CI, 0.62 to 1.00; P=0.05), whereas in the transthoracic-access cohort, outcomes were similar in the two groups. TAVR resulted in larger aortic-valve areas than did surgery and also resulted in lower rates of acute kidney injury, severe bleeding, and new-onset atrial fibrillation; surgery resulted in fewer major vascular complications and less paravalvular aortic regurgitation. CONCLUSIONS: In intermediate-risk patients, TAVR was similar to surgical aortic-valve replacement with respect to the primary end point of death or disabling stroke. (Funded by Edwards Lifesciences; PARTNER 2 ClinicalTrials.gov number, NCT01314313.).


Assuntos
Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Feminino , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Estimativa de Kaplan-Meier , Masculino , Análise Multivariada , Complicações Pós-Operatórias/mortalidade , Fatores de Risco , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/mortalidade , Ultrassonografia
18.
Catheter Cardiovasc Interv ; 93(4): 729-738, 2019 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-30312995

RESUMO

OBJECTIVES: We investigated the hemodynamic durability of the transcatheter aortic valves (TAVs) using the updated Valve Academic Research Consortium-2 (VARC-2) criteria. BACKGROUND: The updated VARC-2 consensus criteria combine flow-dependent and flow-independent echocardiographic parameters for hemodynamic assessment of TAVR. Data on the hemodynamic durability of TAV and clinical risk factors associated with valve hemodynamic deterioration (VHD) are lacking. METHODS: All patients (n = 276) who received TAV between 2006 and 2012 and had ≥2 follow-up echocardiograms were studied. RESULTS: During a median follow up period of 3.3 (1.8-4.4) years, 8 patients (3%) developed moderate to severe valve stenosis per the VARC-2 criteria, while 20 had mild stenosis. In a Cox proportional hazards model analysis, moderate to severe stenosis by VARC-2 criteria was associated with younger age (P = 0.03, HR 0.94), absence of dual antiplatelet therapy (DAPT) (P = 0.026, HR 0.18), and lower baseline left ventricular ejection fraction (LVEF) (P = 0.006, HR 0.94). Longitudinal analysis using a mixed effect model showed that presence of stenosis by VARC-2 criteria was associated with an increase in aortic valve mean gradient (P < 0.001, +2.34 mmHg per year). In a subset of 93 patients with analyzable fluoroscopic images, deeper valve implantation was associated with increase in mean gradient (P = 0.004, +0.2 mmHg per year per 1 mm increase in implantation depth). CONCLUSION: Despite good hemodynamic durability of TAV, patients with younger age, lower LVEF and those not on DAPT after undergoing a TAV replacement, are at a higher risk for development of VHD.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Bioprótese , Próteses Valvulares Cardíacas , Hemodinâmica , Substituição da Valva Aórtica Transcateter/instrumentação , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Feminino , Humanos , Masculino , Inibidores da Agregação Plaquetária/uso terapêutico , Desenho de Prótese , Falha de Prótese , Recidiva , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Estresse Mecânico , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Função Ventricular Esquerda
19.
J Card Surg ; 34(8): 676-683, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31212385

RESUMO

BACKGROUND AND AIM: To compare outcomes of patients treated with inhaled epoprostenol and low tidal volume ventilation during cardiopulmonary bypass with those who did not receive this medication in the operating room at all, and those who received it as a rescue therapy at the end of the case. METHODS: Retrospective chart review between 2014 and 2017, follow-up included the entire hospital stay. RESULTS: Seventy-one patients were included, and mean age was 54 years. 78.9% of the patients were male. Procedures included 96% (n = 68) aortic valve replacement, 28% (n = 20) reconstruction of the intravalvular fibrosa, and 13% (n = 9) repair of an endocarditis-related intracardiac fistula. Patients who received epoprostenol (iEpo) (treatment and rescue groups), when compared with the control group had more intra-aortic balloon pump placement (23% vs 2.5%, P = .018), open chest after surgery (32% vs 7.5%, P = .012), and duration of mechanical ventilation (8.3 ± 2.7 vs. 2.4 ± 0.4 days, P = 0.01). There was no significant difference between the two groups in terms of extracorporeal circulatory support (6.5% vs 2.5%, P = .577) and hospital death (13% vs 10%, P = .72). In a subanalysis, hospital death and duration of mechanical ventilation were higher in the recue group when compared with the treatment group (P = .004 and .056, respectively). CONCLUSIONS: Prophylactic application of iEpo with low tidal volume ventilation for an anticipated complex endocarditis operation may contribute to favorable outcome when compared with postoperative epoprostenol rescue.


Assuntos
Endocardite/cirurgia , Epoprostenol/administração & dosagem , Cuidados Intraoperatórios , Complicações Pós-Operatórias/prevenção & controle , Respiração Artificial/métodos , Síndrome do Desconforto Respiratório/prevenção & controle , Administração por Inalação , Procedimentos Cirúrgicos Cardíacos , Ponte Cardiopulmonar , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência Respiratória/prevenção & controle , Estudos Retrospectivos , Risco , Índice de Gravidade de Doença , Volume de Ventilação Pulmonar , Resultado do Tratamento
20.
Eur Heart J ; 39(28): 2659-2667, 2018 07 21.
Artigo em Inglês | MEDLINE | ID: mdl-29741615

RESUMO

Aims: In patients randomized to transcatheter or surgical aortic valve replacement (TAVR, SAVR), we sought to determine whether SAVR is associated with worsening right ventricular (RV) function and whether RV deterioration is associated with mortality. Methods and results: In 1376 patients from PARTNERIIA with paired baseline and 30-day core lab echocardiograms, worsening RV function was defined as decline by at least one grade from baseline to 30 days. Our primary outcome was all-cause mortality from 30 days to 2 years. Among 744 patients with TAVR, 62 (8.3%) had worsening RV function, compared with 156 of 632 patients with SAVR (24.7%) (P < 0.0001). In a multivariable model, SAVR [odds ratio (OR) 4.05, 95% confidence interval (CI) 2.55-6.44], a dilated RV (OR 2.38, 95% CI 1.37-4.14), and more than mild tricuspid regurgitation (TR) (OR 2.58, 95% CI 1.25-5.33) were associated with worsening RV function. There were 169 deaths, and patients with worsening RV function had higher all-cause mortality [hazard ratio (HR) 1.98, 95% CI 1.40-2.79]. This association remained robust after adjusting for clinical and echocardiographic variables. Among patients with worsening RV function, there was no mortality difference between TAVR and SAVR (HR 1.16, 95% CI 0.61-2.18). The development of moderate or severe RV dysfunction from baseline normal RV function conferred the worst prognosis (HR 2.87, 95% CI 1.40-5.89). Conclusion: After aortic valve replacement, worsening RV function is more common in patients with baseline RV dilation, more than mild TR, and in patients treated with SAVR. Worsening RV function and the magnitude of deterioration have important prognostic implications.


Assuntos
Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Complicações Pós-Operatórias/epidemiologia , Disfunção Ventricular Direita/epidemiologia , Idoso de 80 Anos ou mais , Progressão da Doença , Feminino , Humanos , Incidência , Masculino , Complicações Pós-Operatórias/mortalidade , Prognóstico , Estudos Prospectivos , Substituição da Valva Aórtica Transcateter , Disfunção Ventricular Direita/mortalidade
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa