RESUMO
Importance: Catheter ablation of persistent atrial fibrillation (AF) has limited success. Procedural strategies beyond pulmonary vein isolation have failed to consistently improve results. The vein of Marshall contains innervation and AF triggers that can be ablated by retrograde ethanol infusion. Objective: To determine whether vein of Marshall ethanol infusion could improve ablation results in persistent AF when added to catheter ablation. Design, Setting, and Participants: The Vein of Marshall Ethanol for Untreated Persistent AF (VENUS) trial was an investigator-initiated, National Institutes of Health-funded, randomized, single-blinded trial conducted in 12 centers in the United States. Patients (N = 350) with persistent AF referred for first ablation were enrolled from October 2013 through June 2018. Follow-up concluded in June 2019. Interventions: Patients were randomly assigned to catheter ablation alone (n = 158) or catheter ablation combined with vein of Marshall ethanol infusion (n = 185) in a 1:1.15 ratio to accommodate for 15% technical vein of Marshall ethanol infusion failures. Main Outcomes and Measures: The primary outcome was freedom from AF or atrial tachycardia for longer than 30 seconds after a single procedure, without antiarrhythmic drugs, at both 6 and 12 months. Outcome assessment was blinded to randomization treatment. There were 12 secondary outcomes, including AF burden, freedom from AF after multiple procedures, perimitral block, and others. Results: Of the 343 randomized patients (mean [SD] age, 66.5 [9.7] years; 261 men), 316 (92.1%) completed the trial. Vein of Marshall ethanol was successfully delivered in 155 of 185 patients. At 6 and 12 months, the proportion of patients with freedom from AF/atrial tachycardia after a single procedure was 49.2% (91/185) in the catheter ablation combined with vein of Marshall ethanol infusion group compared with 38% (60/158) in the catheter ablation alone group (difference, 11.2% [95% CI, 0.8%-21.7%]; P = .04). Of the 12 secondary outcomes, 9 were not significantly different, but AF burden (zero burden in 78.3% vs 67.9%; difference, 10.4% [95% CI, 2.9%-17.9%]; P = .01), freedom from AF after multiple procedures (65.2% vs 53.8%; difference, 11.4% [95% CI, 0.6%-22.2%]; P = .04), and success achieving perimitral block (80.6% vs 51.3%; difference, 29.3% [95% CI, 19.3%-39.3%]; P < .001) were significantly improved in vein of Marshall-treated patients. Adverse events were similar between groups. Conclusions and Relevance: Among patients with persistent AF, addition of vein of Marshall ethanol infusion to catheter ablation, compared with catheter ablation alone, increased the likelihood of remaining free of AF or atrial tachycardia at 6 and 12 months. Further research is needed to assess longer-term efficacy. Trial Registration: ClinicalTrials.gov Identifier: NCT01898221.
Assuntos
Fibrilação Atrial/terapia , Ablação por Cateter/métodos , Etanol/administração & dosagem , Veia Cava Superior , Idoso , Terapia Combinada/métodos , Feminino , Humanos , Infusões Intravenosas/efeitos adversos , Infusões Intravenosas/métodos , Estimativa de Kaplan-Meier , Masculino , Método Simples-Cego , Taquicardia/terapia , Resultado do Tratamento , Veia Cava Superior/embriologia , Veia Cava Superior/inervaçãoRESUMO
BACKGROUND: There have been an increasing number of atrial fibrillation (AF) patients with Watchman left atrial appendage occlusion (LAAO) device, requiring catheter ablation (CA) for maintenance of normal sinus rhythm. In this study, we describe our experience with the feasibility and safety of CA in patients with a preexisting Watchman LAAO device. METHODS: This was a retrospective multicenter AF registry of 60 patients with Watchman LAAO device who underwent CA for AF. Baseline clinical and procedural characteristics of the included subjects were retrieved from review of medical records and were analyzed. RESULTS: The mean age was 72.7 ± 4.9 years and the mean CHADS2 score was 2.3 ± 0.6. All patients had successful pulmonary vein isolation (PVI). The left atrial appendage (LAA) was electrically active in 34 (56%) while reentrant tachycardia and AF triggers were seen in 17 (28%) patients. Electrical isolation was attempted in these 17 patients with only 10 achieving complete LAA isolation. Repeat imaging showed new peri-device leaks in 30% (12/40) patients, while new significant peri-device leaks (≥5 mm) were noted in 10% (10/40) of patients after RFA, respectively, requiring continuation of oral anticoagulation. There were a higher proportion of patients with severe peri-device leaks (≥5 mm) after LAA isolation. However, >50% of those leaks sealed off on follow-up transesophageal echocardiogram. CONCLUSION: AF ablation is a feasible and safe in patients with preexisting Watchman LAAO device. Electrical isolation of the LAA could be difficult and when attempted can result in increased risk of short-term peri-device leak and recurrence of AT/AF in almost all patients.
Assuntos
Apêndice Atrial , Fibrilação Atrial/cirurgia , Cateterismo Cardíaco/instrumentação , Ablação por Cateter , Comunicação Interatrial/terapia , Dispositivo para Oclusão Septal , Potenciais de Ação , Idoso , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Cateterismo Cardíaco/efeitos adversos , Ablação por Cateter/efeitos adversos , Ecocardiografia , Técnicas Eletrofisiológicas Cardíacas , Estudos de Viabilidade , Feminino , Frequência Cardíaca , Comunicação Interatrial/diagnóstico , Comunicação Interatrial/fisiopatologia , Humanos , Masculino , Desenho de Prótese , Recidiva , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Estados UnidosRESUMO
AIMS: Focal Impulse and Rotor Modulation (FIRM) uses 64-electrode basket catheters to identify atrial fibrillation (AF)-sustaining sites for ablation, with promising results in many studies. Accordingly, new basket designs are being tested by several groups. We set out to determine the procedural safety of adding basket mapping and map-guided ablation to conventional pulmonary vein isolation (PVI). METHODS AND RESULTS: We collected 30 day procedural safety data in five US centres for consecutive patients undergoing FIRM plus PVI (FIRM-PVI) compared with contemporaneous controls undergoing PVI without FIRM. A total of 625 cases were included in this analysis: 325 FIRM-PVI and 300 PVI-controls. FIRM-PVI patients were more likely than PVI-controls to be male (83% vs. 66%, P < 0.001) and have long-standing persistent AF (26% vs. 13%, P < 0.001) reflecting patients referred for FIRM. Total ablation time was greater for FIRM-PVI (62 ± 22 min) vs. PVI-controls (52 ± 18 min, P = 0.03). The complication rate for FIRM-PVI procedures (4.3%) was similar to controls (4.0%, P = 1) for both major and minor complications; no deaths were reported. The rate of complications potentially attributable to the basket catheter was small and did not differ between basket types (Constellation 2.8% vs. FIRMap 1.8%, P = 0.7) or between cases in which basket catheters were and were not used (P = 0.5). Complication rates did not differ between centres (P = 0.6). CONCLUSIONS: Procedural complications from the use of the basket catheters for AF mapping are low, and thus procedural safety appears similar between FIRM-PVI and PVI-controls in a large multicentre cohort. Future studies are required to determine the optimal approach to maximize the efficacy of FIRM-guided ablation.
Assuntos
Fibrilação Atrial/mortalidade , Fibrilação Atrial/cirurgia , Mapeamento Potencial de Superfície Corporal/mortalidade , Ablação por Cateter/mortalidade , Ablação por Cateter/estatística & dados numéricos , Complicações Pós-Operatórias/mortalidade , Cirurgia Assistida por Computador/mortalidade , Fibrilação Atrial/diagnóstico por imagem , Mapeamento Potencial de Superfície Corporal/métodos , Mapeamento Potencial de Superfície Corporal/estatística & dados numéricos , Ablação por Cateter/métodos , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/prevenção & controle , Prevalência , Fatores de Risco , Cirurgia Assistida por Computador/métodos , Cirurgia Assistida por Computador/estatística & dados numéricos , Taxa de Sobrevida , Resultado do Tratamento , Estados Unidos/epidemiologiaRESUMO
BACKGROUND: Silent cerebral lesions (SCLs) are a potential complication of left atrial radiofrequency ablation (RFA) procedures for paroxysmal atrial fibrillation (PAF). We aimed to compare the incidence of SCLs in patients treated with irrigated RFA multielectrode catheters (nMARQ® Catheter group) and irrigated focal RFA catheters (NAVISTAR® THERMOCOOL® Catheter; TC group) after PAF ablation from subpopulation neurological assessment (SNA) cohorts of the REVOLUTION and reMARQable studies. METHODS: Data from SNA cohorts in the prospective, nonrandomized REVOLUTION study (March 2011-September 2013) and the prospective, randomized, controlled reMARQable study (October 2013-November 2015) were included. The incidence of SCLs was assessed pre- and postablation using magnetic resonance imaging. Neurological deficits were assessed using the National Institutes of Health Stroke Scale, modified Rankin Scale, and Montreal Cognitive Assessment. RESULTS: A total of 37 patients from REVOLUTION and 76 patients from reMARQable were included in the SNA cohort of each study. In the REVOLUTION SNA cohort, the incidence of SCLs was 21.1% (4/19) in the nMARQ® Catheter group and 5.9% (1/17) in the TC group. Findings from REVOLUTION helped inform the reMARQable study protocol's stringent anticoagulation regimen. SCL incidence was subsequently reduced in both groups (nMARQ® Catheter, 7.9%; TC, 3.3%). No permanent neurological deficits were observed. CONCLUSION: Adherence to a stringent anticoagulation regimen prior to and during ablation procedures appears to be an important factor in minimizing the risk of SCL.
Assuntos
Anticoagulantes/efeitos adversos , Doenças Assintomáticas , Encefalopatias/etiologia , Encefalopatias/prevenção & controle , Ablação por Cateter/efeitos adversos , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/prevenção & controle , Fibrilação Atrial/cirurgia , Coagulação Sanguínea , Encefalopatias/epidemiologia , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/epidemiologia , Estudos Prospectivos , Ensaios Clínicos Controlados Aleatórios como AssuntoRESUMO
INTRODUCTION: Several groups report electrical rotors or focal sources that sustain atrial fibrillation (AF) after it has been triggered. However, it is difficult to separate stable from unstable activity in prior studies that examined only seconds of AF. We applied phase-based focal impulse and rotor mapping (FIRM) to study the dynamics of rotors/sources in human AF over prolonged periods of time. METHODS: We prospectively mapped AF in 260 patients (169 persistent, 61 ± 12 years) at 6 centers in the FIRM registry, using baskets with 64 contact electrodes per atrium. AF was phase mapped (RhythmView, Topera, Menlo Park, CA, USA). AF propagation movies were interpreted by each operator to assess the source stability/dynamics over tens of minutes before ablation. RESULTS: Sources were identified in 258 of 260 of patients (99%), for 2.8 ± 1.4 sources/patient (1.8 ± 1.1 in left, 1.1 ± 0.8 in right atria). While AF sources precessed in stable regions, emanating activity including spiral waves varied from collision/fusion (fibrillatory conduction). Each source lay in stable atrial regions for 4,196 ± 6,360 cycles, with no differences between paroxysmal versus persistent AF (4,290 ± 5,847 vs. 4,150 ± 6,604; P = 0.78), or right versus left atrial sources (P = 0.26). CONCLUSIONS: Rotors and focal sources for human AF mapped by FIRM over prolonged time periods precess ("wobble") but remain within stable regions for thousands of cycles. Conversely, emanating activity such as spiral waves disorganize and collide with the fibrillatory milieu, explaining difficulties in using activation mapping or signal processing analyses at fixed electrodes to detect AF rotors. These results provide a rationale for targeted ablation at AF sources rather than fibrillatory spiral waves.
Assuntos
Algoritmos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Relógios Biológicos , Mapeamento Potencial de Superfície Corporal/métodos , Sistema de Condução Cardíaco/fisiopatologia , Doença Crônica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Cardiovasculares , Condução Nervosa , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Estados UnidosRESUMO
INTRODUCTION: The success of pulmonary vein isolation (PVI) for atrial fibrillation (AF) may be improved if stable AF sources identified by Focal Impulse and Rotor Mapping (FIRM) are also eliminated. The long-term results of this approach are unclear outside the centers where FIRM was developed; thus, we assessed outcomes of FIRM-guided AF ablation in the first cases at 10 experienced centers. METHODS: We prospectively enrolled n = 78 consecutive patients (61 ± 10 years) undergoing FIRM guided ablation for persistent (n = 48), longstanding persistent (n = 7), or paroxysmal (n = 23) AF. AF recordings from both atria with a 64-pole basket catheter were analyzed using a novel mapping system (Rhythm View(TM) ; Topera Inc., CA, USA). Identified rotors/focal sources were ablated, followed by PVI. RESULTS: Each institution recruited a median of 6 patients, each of whom showed 2.3 ± 0.9 AF rotors/focal sources in diverse locations. 25.3% of all sources were right atrial (RA), and 50.0% of patients had ≥1 RA source. Ablation of all sources required a total of 16.6 ± 11.7 minutes, followed by PVI. On >1 year follow-up with a 3-month blanking period, 1 patient lost to follow-up (median time to 1st recurrence: 245 days, IQR 145-354), single-procedure freedom from AF was 87.5% (patients without prior ablation; 35/40) and 80.5% (all patients; 62/77) and similar for persistent and paroxysmal AF (P = 0.89). CONCLUSIONS: Elimination of patient-specific AF rotors/focal sources produced freedom-from-AF of ≈80% at 1 year at centers new to FIRM. FIRM-guided ablation has a rapid learning curve, yielding similar results to original FIRM reports in each center's first cases.
Assuntos
Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sistema de Registros , Resultado do TratamentoRESUMO
IMPORTANCE: While effective in preventing stroke in patients with atrial fibrillation (AF), warfarin is limited by a narrow therapeutic profile, a need for lifelong coagulation monitoring, and multiple drug and diet interactions. OBJECTIVE: To determine whether a local strategy of mechanical left atrial appendage (LAA) closure was noninferior to warfarin. DESIGN, SETTING, AND PARTICIPANTS: PROTECT AF was a multicenter, randomized (2:1), unblinded, Bayesian-designed study conducted at 59 hospitals of 707 patients with nonvalvular AF and at least 1 additional stroke risk factor (CHADS2 score ≥1). Enrollment occurred between February 2005 and June 2008 and included 4-year follow-up through October 2012. Noninferiority required a posterior probability greater than 97.5% and superiority a probability of 95% or greater; the noninferiority margin was a rate ratio of 2.0 comparing event rates between treatment groups. INTERVENTIONS: Left atrial appendage closure with the device (n = 463) or warfarin (n = 244; target international normalized ratio, 2-3). MAIN OUTCOMES AND MEASURES: A composite efficacy end point including stroke, systemic embolism, and cardiovascular/unexplained death, analyzed by intention-to-treat. RESULTS: At a mean (SD) follow-up of 3.8 (1.7) years (2621 patient-years), there were 39 events among 463 patients (8.4%) in the device group for a primary event rate of 2.3 events per 100 patient-years, compared with 34 events among 244 patients (13.9%) for a primary event rate of 3.8 events per 100 patient-years with warfarin (rate ratio, 0.60; 95% credible interval, 0.41-1.05), meeting prespecified criteria for both noninferiority (posterior probability, >99.9%) and superiority (posterior probability, 96.0%). Patients in the device group demonstrated lower rates of both cardiovascular mortality (1.0 events per 100 patient-years for the device group [17/463 patients, 3.7%] vs 2.4 events per 100 patient-years with warfarin [22/244 patients, 9.0%]; hazard ratio [HR], 0.40; 95% CI, 0.21-0.75; P = .005) and all-cause mortality (3.2 events per 100 patient-years for the device group [57/466 patients, 12.3%] vs 4.8 events per 100 patient-years with warfarin [44/244 patients, 18.0%]; HR, 0.66; 95% CI, 0.45-0.98; P = .04). CONCLUSIONS AND RELEVANCE: After 3.8 years of follow-up among patients with nonvalvular AF at elevated risk for stroke, percutaneous LAA closure met criteria for both noninferiority and superiority, compared with warfarin, for preventing the combined outcome of stroke, systemic embolism, and cardiovascular death, as well as superiority for cardiovascular and all-cause mortality. TRIAL REGISTRATION: clinicaltrials.gov Identifier: NCT00129545.
Assuntos
Apêndice Atrial/fisiopatologia , Fibrilação Atrial/tratamento farmacológico , Embolia/prevenção & controle , Implantação de Prótese , Acidente Vascular Cerebral/prevenção & controle , Varfarina/uso terapêutico , Idoso , Idoso de 80 Anos ou mais , Anticoagulantes/uso terapêutico , Fibrilação Atrial/complicações , Teorema de Bayes , Cateterismo Cardíaco , Doenças Cardiovasculares/prevenção & controle , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Risco , Análise de Sobrevida , Resultado do TratamentoRESUMO
BACKGROUND: Atrial fibrillation (AF) is a common comorbidity in patients with heart failure with preserved ejection fraction (HFpEF) and in heart failure with mildly reduced ejection fraction (HFmrEF). OBJECTIVES: This study sought to describe AF burden and its clinical impact among individuals with HFpEF and HFmrEF who participated in a randomized clinical trial of atrial shunt therapy (REDUCE LAP-HF II [A Study to Evaluate the Corvia Medical, Inc IASD System II to Reduce Elevated Left Atrial Pressure in Patients with Heart Failure]) and to evaluate the effect of atrial shunt therapy on AF burden. METHODS: Study investigators characterized AF burden among patients in the REDUCE LAP-HF II trial by using ambulatory cardiac patch monitoring at baseline (median patch wear time, 6 days) and over a 12-month follow-up (median patch wear time, 125 days). The investigators determined the association of baseline AF burden with long-term clinical events and examined the effect of atrial shunt therapy on AF burden over time. RESULTS: Among 367 patients with cardiac monitoring data at baseline and follow-up, 194 (53%) had a history of AF or atrial flutter (AFL), and median baseline AF burden was 0.012% (IQR: 0%-1.3%). After multivariable adjustment, baseline AF burden ≥0.012% was significantly associated with heart failure (HF) events (HR: 2.00; 95% CI: 1.17-3.44; P = 0.01) both with and without a history of AF or AFL (P for interaction = 0.68). Adjustment for left atrial reservoir strain attenuated the baseline AF burden-HF event association (HR: 1.71; 95% CI: 0.93-3.14; P = 0.08). Of the 367 patients, 141 (38%) had patch-detected AF during follow-up without a history of AF or AFL. Atrial shunt therapy did not change AF incidence or burden during follow-up. CONCLUSIONS: In HFpEF and HFmrEF, nearly 40% of patients have subclinical AF by 1 year. Baseline AF burden, even at low levels, is associated with HF events. Atrial shunt therapy does not affect AF incidence or burden. (A Study to Evaluate the Corvia Medical, Inc IASD System II to Reduce Elevated Left Atrial Pressure in Patients with Heart Failure [REDUCE LAP-HF II]; NCT03088033).
Assuntos
Fibrilação Atrial , Insuficiência Cardíaca , Humanos , Fibrilação Atrial/epidemiologia , Volume Sistólico , Átrios do Coração , Implantação de Prótese , PrognósticoRESUMO
Rotating spiral waves are self-organized features in spatially extended excitable media and may play an important role in cardiac arrhythmias including atrial fibrillation (AF). In homogeneous media, spiral wave dynamics are perpetuated through spiral wave breakup, leading to the continuous birth and death of spiral waves, but have a finite probability of termination. In non-homogeneous media, however, heterogeneities can act as anchoring sources that result in sustained spiral wave activity. It is thus unclear how and if AF may terminate following the removal of putative spiral wave sources in patients. Here, we address this question using computer simulations in which a stable spiral wave is trapped by an heterogeneity and is surrounded by spiral wave breakup. We show that, following ablation of spatial heterogeneity to render that region of the medium unexcitable, termination of spiral wave dynamics is stochastic and Poisson-distributed. Furthermore, we show that the dynamics can be accurately described by a master equation using birth and death rates. To validate these predictions in vivo, we mapped spiral wave activity in patients with AF and targeted the locations of spiral wave sources using radiofrequency ablation. Targeted ablation was indeed able to terminate AF, but only after a variable delay of up to several minutes. Furthermore, and consistent with numerical simulations, termination was not accompanied by gradual temporal or spatial organization. Our results suggest that spiral wave sources and tissue heterogeneities play a critical role in the maintenance of AF and that the removal of sources results in spiral wave dynamics with a finite termination time, which could have important clinical implications.
RESUMO
BACKGROUND: Incomplete left atrial appendage (LAA) closure is an evolving topic of clinical significance and thromboembolic potential, with recent long-term studies suggesting lower cutoffs for relevant leak size. OBJECTIVES: The aim of this prospective observational study was to assess 3 different closure techniques for persistent peridevice leaks after incomplete LAA closure and compare their efficacy and safety outcomes. METHODS: We studied 160 patients (mean age 72 ± 9 years; 71% men) who underwent 1 of the 3 available modalities (detachable embolization coils, vascular plugs or septal occluders, and radiofrequency ablation) for residual central or eccentric leak closure. Both acute postprocedural success (closure or <1-mm leak at the end of the procedure) and closure at 1-year follow-up transesophageal echocardiography imaging were evaluated. RESULTS: Of 160 patients, 0.6%, 41.3%, and 58.1% had mild (1-2 mm), moderate (3-5 mm), and severe (≥5 mm) leaks, respectively. Baseline LAA closure type was 72.5% Watchman FLX, 16.3% Lariat, 5.6% surgical ligation, 1.9% AtriClip, and 1.9% Amulet. Successful closure (0- or <1-mm leak) was seen in 100% of patients in all cohorts following intervention, with overall complete closure (0-1 mm) or mild or minimal leaks (1-2 mm) on 1-year follow-up transesophageal echocardiography seen in 100% of the atrial septal occluder or vascular plug cohort, 85.9% of the coil cohort, and 83.3% of the radiofrequency ablation cohort (P < 0.001). Two patients (1.3%) experienced cardiac tamponade, and there were no deaths or other complications. CONCLUSIONS: Peridevice leaks can safely and effectively be closed using 3 different modalities depending on size and location.
Assuntos
Apêndice Atrial , Fibrilação Atrial , Dispositivo para Oclusão Septal , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Feminino , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/terapia , Fibrilação Atrial/complicações , Resultado do Tratamento , Ecocardiografia Transesofagiana , Cateterismo Cardíaco/efeitos adversosRESUMO
BACKGROUND: The Vein of Marshall Ethanol for Untreated Persistent AF (VENUS) trial demonstrated that adding vein of Marshall (VOM) ethanol infusion to catheter ablation (CA) improves ablation outcomes in persistent atrial fibrillation (AF). There was significant heterogeneity in the impact of VOM ethanol infusion on rhythm control. OBJECTIVE: The purpose of this study was to assess the association between outcomes and (1) achievement of bidirectional perimitral conduction block and (2) procedural volume. METHODS: The VENUS trial randomized patients with persistent AF (N = 343) to CA combined with VOM ethanol or CA alone. The primary outcome (freedom from AF or atrial tachycardia [AT] lasting longer than 30 seconds after a single procedure) was analyzed by 2 categories: (1) successful vs no perimitral block and (2) high- (>20 patients enrolled) vs low-volume centers. RESULTS: In patients with perimitral block, the primary outcome was reached 54.3% after VOM-CA and 37% after CA alone (P = .01). Among patients without perimitral block, freedom from AF/AT was 34.0% after VOM-CA and 37.0% after CA (P = .583). In high-volume centers, the primary outcome was reached in 56.4% after VOM-CA and 40.2% after CA (P = .01). In low-volume centers, freedom from AF/AT was 30.77% after VOM-CA and 32.61% after CA (P = .84). In patients with successful perimitral block from high-volume centers, the primary outcome was reached in 59% after VOM-CA and 39.1% after CA (P = .01). Tests for interaction were significant (P = .002 for perimitral block and P = .04 for center volume). CONCLUSION: Adding VOM ethanol infusion to CA has a greater impact on outcomes when associated with perimitral block and performed in high-volume centers. Perimitral block should be part of the VOM procedure.
Assuntos
Fibrilação Atrial/terapia , Ablação por Cateter/métodos , Etanol/administração & dosagem , Sistema de Condução Cardíaco/fisiopatologia , Frequência Cardíaca/fisiologia , Veias Pulmonares/cirurgia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/fisiopatologia , Feminino , Humanos , Infusões Intravenosas , Masculino , Pessoa de Meia-Idade , Recidiva , Resultado do Tratamento , Adulto JovemRESUMO
BACKGROUND: Esophageal thermal injury is a feared complication of radiofrequency ablation for atrial fibrillation (AF). Rise in luminal esophageal temperature (LET) limits the ability to deliver radiofrequency energy on the posterior wall of the left atrium. OBJECTIVE: The purpose of this study was to evaluate the feasibility, safety, and efficacy of a mechanical esophageal deviation (ED) tool during AF ablation. METHODS: We evaluated 687 patients who underwent radiofrequency ablation for AF. In 209 patients, the EsoSure (Northeast Scientific) was used to deflect the esophagus away from the ablation site. Propensity score matching was performed to obtain 180 patients each in the ED and non-ED arms. ED was used for LET rise seen in 61.7% of patients (111/180) and was used if the esophagus was in the line of ablation on fluoroscopy in 38.3% of patients (69/180). RESULTS: Mean deviation of trailing edge of esophagus with EsoSure was 2.45 ± 0.9 cm (range 1-4.5). LET rise >1°C was significantly lower in the ED than non-ED group (3% vs 79.4%; P <.001). Mean LET rise was also lower in the ED arm (ED 0.34 ± 0.59 vs non-ED 1.66 ± 0.54; P <.001). Intraprocedural success of pulmonary vein antral isolation, was slightly improved in the ED arm than in the non-ED arm without statistical significance. AF recurrence was lower in the ED arm at 3-month, 6-month, and 1-year follow-up than in the non-ED arm. No ED-related complications were noted. CONCLUSION: Mechanical displacement of the esophagus with EsoSure seems to be feasible, safe, and efficacious in enabling adequate radiofrequency energy delivery to the posterior wall of the left atrium without significant LET rise and obvious clinical signs of esophageal injury.
Assuntos
Ligas , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Esôfago/fisiopatologia , Átrios do Coração/cirurgia , Monitorização Intraoperatória/métodos , Complicações Pós-Operatórias/prevenção & controle , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Temperatura Corporal , Ecocardiografia Transesofagiana , Esôfago/diagnóstico por imagem , Esôfago/lesões , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/cirurgia , Estudos Retrospectivos , Fatores de Tempo , Resultado do TratamentoRESUMO
BACKGROUND: In a randomized trial, baroreflex activation therapy (BAT) improved exercise capacity, quality of life and NT-proBNP in patients with heart failure with reduced ejection fraction (HFrEF). In view of different mechanisms underlying HFrEF, we performed a post-hoc subgroup analysis of efficacy and safety of BAT in patients with and without coronary artery disease (CAD). METHODS AND RESULTS: Patients with left ventricular ejection fraction <35% and NYHA Class III were randomized 1:1 to guideline-directed medical and device therapy alone or plus BAT. Patients with a history of CAD, prior myocardial infarction or coronary artery bypass graft were assigned to the CAD group with all others assigned to the no-CAD group. Of 71 BAT treated patients, 52 had CAD and 19 had no CAD. In the control group, 49 of 69 patients had CAD and 20 had no CAD. The system- or procedure-related major adverse neurological or cardiovascular event rate was 3.8% in the CAD group vs. 0% in the no-CAD group (pâ¯=â¯1.0). In the whole cohort, NYHA Class, Minnesota Living with Heart Failure score, 6-minute hall walk distance and NTproBNP were improved in BAT treated patients compared with controls. Statistical analyses revealed no interaction between the presence of CAD and effect of BAT (all pâ¯>â¯0.05). CONCLUSION: No major differences were found in BAT efficacy or safety between patients with and without CAD, indicating that BAT improves exercise capacity, quality of life and NTproBNP in patients with ischemic and non-ischemic cardiomyopathy. CLINICALTRIALS. GOV IDENTIFIER: NCT01471860 and NCT01720160.
Assuntos
Barorreflexo/fisiologia , Doença da Artéria Coronariana/terapia , Terapia por Estimulação Elétrica/métodos , Insuficiência Cardíaca/terapia , Volume Sistólico/fisiologia , Biomarcadores/sangue , Doença da Artéria Coronariana/sangue , Doença da Artéria Coronariana/fisiopatologia , Terapia por Estimulação Elétrica/instrumentação , Feminino , Insuficiência Cardíaca/sangue , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Peptídeo Natriurético Encefálico/sangue , Fragmentos de Peptídeos/sangue , Estudos Retrospectivos , Resultado do TratamentoRESUMO
BACKGROUND: Pocket hematoma is a recognized complication after placement of cardiac implantable electronic devices and is associated with increased device infection, length of hospitalization, and morbidity especially with uninterrupted antiplatelet agents and anticoagulants. We assessed the use of a post-surgical vest to decrease the incidence of pocket hematoma in patients undergoing device implantation with uninterrupted antiplatelet and anticoagulants. METHODS: In this observational study, a vest was used by 20 consecutive patients who were compared to 20 age-, gender-, procedure-matched patients who received standard care. All patients were continued on antiplatelet and anticoagulants in the perioperative period. The pocket was assessed at post procedure day 0, 2, and 7, respectively. RESULTS: There were no significant differences in the baseline characteristics between both groups. Baseline mean international normalized ratio (INR) was significantly higher in the vest group when compared with the control group (2.7 ± 0.4 vs. 2.2 ± 0.3 = <0.001). The incidence of pocket hematoma was significantly lower in the vest group than the control group (0 vs 30%, p = 0.02) at the end of 7 days. Control group had a total of six hematomas with one patient requiring evacuation and blood transfusion. The vest group had three hematomas on day 2 that resolved by day 7. CONCLUSIONS: The risk of moderate or large pocket hematoma is significantly reduced with the use of this vest in high-risk patients undergoing implantable devices on uninterrupted antiplatelet and anticoagulants.
Assuntos
Bandagens Compressivas , Desfibriladores Implantáveis/efeitos adversos , Hematoma/etiologia , Hematoma/prevenção & controle , Marca-Passo Artificial/efeitos adversos , Anticoagulantes/uso terapêutico , Estudos de Casos e Controles , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Inibidores da Agregação Plaquetária/uso terapêutico , Fatores de RiscoRESUMO
OBJECTIVES: The present study describes the use of octreotide (OCT) in patients with atrial fibrillation (AF) receiving oral anticoagulation (OAC) who have gastrointestinal (GI) bleeding related to arteriovenous malformations (AVMs), as well as its effect on OAC tolerance and subsequent rebleeding. BACKGROUND: AVMs cause significant GI bleeding, especially in patients with AF who are receiving OAC for stroke prevention. OCT has been shown to minimize recurrent GI bleeds related to AVMs. METHODS: In a multicenter, observational study, 38 AF patients with contraindications to OAC because of AVM-related GI bleeding were started on 100 µg of subcutaneous OCT twice daily. OAC was resumed in all patients within 48 h. Incidence of recurrent GI bleeds was calculated, and hemoglobin levels were recorded at enrollment and at 3 and 6 months' follow-up. RESULTS: After a median follow-up of 8 months, 36 patients (mean age 69 ± 8.0 years; mean CHA2DS2-VASc score 3 ± 1 and mean HAS-BLED score 3 ± 1) were available for analysis. All were able to successfully resume OAC, and 28 of 36 (78%) remained on OAC at the conclusion of the study, whereas 8 underwent left atrial appendage closure with subsequent OAC discontinuation. No systemic thromboembolic events occurred in follow-up. Of the 28 patients who continued receiving OAC, 19 (68%) were free of recurrent GI bleed, 4 had minor GI bleeds, 4 required transfusion, and 1 required colectomy for GI bleeding. Mean hemoglobin levels in all patients receiving OAC were significantly higher at 3- and 6-month follow-up than at baseline (p < 0.001). CONCLUSIONS: Subcutaneous OCT therapy is an attractive option in AF patients receiving OAC who have AVM-related GI bleeds. It allows successful reinitiation of OAC as a bridge to left atrial appendage exclusion or short-term relief from bleeding.
Assuntos
Malformações Arteriovenosas/complicações , Fibrilação Atrial/tratamento farmacológico , Hemorragia Gastrointestinal/prevenção & controle , Octreotida/administração & dosagem , Idoso , Malformações Arteriovenosas/diagnóstico por imagem , Apêndice Atrial/cirurgia , Fibrilação Atrial/complicações , Colectomia , Feminino , Seguimentos , Fármacos Gastrointestinais/uso terapêutico , Hemorragia Gastrointestinal/etiologia , Hemorragia Gastrointestinal/cirurgia , Humanos , Injeções Subcutâneas , Masculino , Pessoa de Meia-Idade , Octreotida/uso terapêutico , Medição de Risco , Acidente Vascular Cerebral/tratamento farmacológico , Acidente Vascular Cerebral/prevenção & controleRESUMO
INTRODUCTION: The role of atrial fibrillation (AF) substrates is unclear in patients with paroxysmal AF (PAF) that recurs after pulmonary vein isolation (PVI). We hypothesized that patients with recurrent post-ablation (redo) PAF despite PVI have electrical substrates marked by rotors and focal sources, and structural substrates that resemble persistent AF more than patients with (de novo) PAF at first ablation. METHODS: In 175 patients at 11 centers, we compared AF substrates in both atria using 64 pole-basket catheters and phase mapping, and indices of anatomical remodeling between patients with de novo or redo PAF and first ablation for persistent AF. RESULTS: Sources were seen in all patients. More patients with de novo PAF (78.0%) had sources near PVs than patients with redo PAF (47.4%, p=0.005) or persistent AF (46.9%, p=0.001). The total number of sources per patient (p=0.444), and number of non-PV sources (p=0.701) were similar between groups, indicating that redo PAF patients had residual non-PV sources after elimination of PV sources by prior PVI. Structurally, left atrial size did not separate de novo from redo PAF (49.5±9.5 vs. 49.0±7.1mm, p=0.956) but was larger in patients with persistent AF (55.2±8.4mm, p=0.001). CONCLUSIONS: Patients with paroxysmal AF despite prior PVI show electrical substrates that resemble persistent AF more closely than patients with paroxysmal AF at first ablation. Notably, these subgroups of paroxysmal AF are indistinguishable by structural indices. These data motivate studies of trigger versus substrate mechanisms for patients with recurrent paroxysmal AF after PVI.
Assuntos
Fibrilação Atrial/patologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Humanos , Recidiva , Reoperação , Resultado do TratamentoRESUMO
BACKGROUND: In the stroke prevention trials of left atrial appendage closure with the Watchman device (Boston Scientific), a postimplantation antithrombotic regimen of 6 weeks of warfarin was used. OBJECTIVE: Given the clinical complexity of warfarin use, the purpose of this study was to study the relative feasibility and safety of using non-warfarin oral anticoagulants (NOACs) instead of warfarin during the peri- and initial postimplantation periods after Watchman implantation. METHODS: This was a retrospective multicenter study of consecutive patients undergoing Watchman implantation and receiving peri- and postprocedural NOACs or warfarin. Transesophageal echocardiography or chest computed tomography was performed between 6 weeks and 4 months postimplant to assess for device-related thrombosis. Bleeding and thromboembolic events also were evaluated at the time of follow-up. RESULTS: In 5 centers, 214 patients received NOACs (46% apixaban, 46% rivaroxaban, 7% dabigatran, and 1% edoxaban) in either an uninterrupted (82%) or a single-held-dose (16%) fashion. Compared to a control group receiving uninterrupted warfarin (n = 212), the rates of periprocedural complications, including bleeding events, were similar (2.8% vs 2.4%, P = 1). At follow-up, the rates of device-related thrombosis (0.9% vs 0.5%, P = 1), composite of thromboembolism or device-related thrombosis (1.4% vs 0.9%, P = 1), and postprocedure bleeding events (0.5% vs 0.9%, P = .6) also were comparable between the NOAC and warfarin groups. CONCLUSION: NOACs proved to be a feasible peri- and postprocedural alternative regimen to warfarin for preventing device-related thrombosis and thromboembolic complications expected early after appendage closure with the Watchman device, without increasing the risk of bleeding.
Assuntos
Anticoagulantes/administração & dosagem , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Implantação de Prótese/efeitos adversos , Tromboembolia/prevenção & controle , Administração Oral , Idoso , Idoso de 80 Anos ou mais , Anticoagulantes/farmacologia , Apêndice Atrial/efeitos dos fármacos , Fibrilação Atrial/prevenção & controle , Estudos de Coortes , Ecocardiografia Transesofagiana/métodos , Feminino , Seguimentos , Humanos , Masculino , Próteses e Implantes , Implantação de Prótese/métodos , Estudos Retrospectivos , Medição de Risco , Tromboembolia/etiologia , Resultado do Tratamento , Varfarina/administração & dosagemRESUMO
The purpose of this publication is to describe the intraoperative experience along with long-term safety and efficacy of the second-generation baroreflex activation therapy (BAT) system in patients with heart failure (HF) and reduced ejection fraction HF (HFrEF). In a randomized trial of New York Heart Association Class III HFrEF, 140 patients were assigned 1:1 to receive BAT plus medical therapy or medical therapy alone. Procedural information along with safety and efficacy data were collected and analyzed over 12 months. Within the cohort of 71 patients randomized to BAT, implant procedure time decreased with experience, from 106 ± 37 minutes on the first case to 83 ± 32 minutes on the third case. The rate of freedom from system- and procedure-related complications was 86% through 12 months, with the percentage of days alive without a complication related to system, procedure, or underlying cardiovascular condition identical to the control group. The complications that did occur were generally mild and short-lived. Overall, 12 months therapeutic benefit from BAT was consistent with previously reported efficacy through 6 months: there was a significant and sustained beneficial treatment effect on New York Heart Association functional Class, quality of life, 6-minute hall walk distance, plasma N-terminal pro-brain natriuretic peptide, and systolic blood pressure. This was true for the full trial cohort and a predefined subset not receiving cardiac resynchronization therapy. There is a rapid learning curve for the specialized procedures entailed in a BAT system implant. BAT system implantation is safe with the therapeutic benefits of BAT in patients with HFrEF being substantial and maintained for at least 1 year.
Assuntos
Barorreflexo , Seio Carotídeo/inervação , Terapia por Estimulação Elétrica , Insuficiência Cardíaca/terapia , Implantação de Prótese , Volume Sistólico , Função Ventricular Esquerda , Biomarcadores/sangue , Terapia por Estimulação Elétrica/efeitos adversos , Terapia por Estimulação Elétrica/instrumentação , Tolerância ao Exercício , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Humanos , Neuroestimuladores Implantáveis , Peptídeo Natriurético Encefálico/sangue , Fragmentos de Peptídeos/sangue , Complicações Pós-Operatórias/etiologia , Implantação de Prótese/efeitos adversos , Implantação de Prótese/instrumentação , Qualidade de Vida , Recuperação de Função Fisiológica , Fatores de Tempo , Resultado do TratamentoRESUMO
Despite significant advances in our understanding of atrial fibrillation (AF) mechanisms in the last 15 years, ablation outcomes remain suboptimal. A potential reason is that many ablation techniques focus on anatomic, rather than patient-specific functional targets for ablation. Panoramic contact mapping, incorporating phase analysis, repolarization and conduction dynamics, and oscillations in AF rate, overcomes many prior difficulties with mapping AF. This approach provides evidence that the mechanisms sustaining human AF are deterministic, largely due to stable electrical rotors and focal sources in either atrium. Ablation of such sources (Focal Impulse and Rotor Modulation: FIRM ablation) has been shown to improve ablation outcome compared with conventional ablation alone; independent laboratories directly targeting stable rotors have shown similar results. Clinical trials examining the role of stand-alone FIRM ablation are in progress. Looking forward, translating insights from patient-specific mapping to evidence-based guidelines and clinical practice is the next challenge in improving patient outcomes in AF management.
RESUMO
BACKGROUND: A dry epicardial access (EA) is increasingly used for advanced cardiovascular procedures. Conventionally used large bore needles (Tuohy or Pajunk needle; LBN) have been associated with low but definite incidence of major complications with EA. Use of micropuncture needle (MPN) may decrease the risk of complications. We intended to compare the outcomes of LBN with MPN for EA. METHODS AND RESULTS: We report a multicenter observational study of consecutive patients who underwent EA for ventricular tachycardia ablation or Lariat procedure using the LBN or MPN. Oral anticoagulation was stopped before the procedure. Baseline characteristics and procedure-related complications were collected and compared. Of the 404 patients, LBN and MPN were used in 46% and 54% of patients, respectively. There was no significant difference in the incidence of inadvertent puncture of myocardium between LBN and MPN (7.6% versus 6.8%, P=0.76). However, there was a significantly higher rate of large pericardial effusions with LBN compared with MPN (8.1% versus 0.9%; P<0.001). The incidence of pleural effusions were not significantly different between both (1.6% versus 2.3%; P=0.64). LBN group had an increase in other complications compared with MPN (open heart surgery to repair cardiac laceration [6 versus 0], injury to liver [1 versus 0], coronaries [1 versus 0], and superior epigastric artery requiring surgical exploration [0 versus 1]). CONCLUSIONS: The use of MPN is associated with decreased incidence of major complications, and the need for surgical repair and routine use should be considered for EA.