Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Cardiovasc Electrophysiol ; 33(5): 966-972, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35262245

RESUMO

BACKGROUND: Focal ventricular arrhythmias (VAs) originating from the intramural myocardium of the basal septum are difficult to localize and ablate. Proximal septal veins emptying into the great cardiac vein can reach close to the origin of intramural arrhythmias. OBJECTIVE: To assess characteristics of proximal septal coronary veins in patients with intramural VAs. METHODS AND RESULTS: Among 84 consecutive patients with intramural VAs, 29 patients (age 60 ± 11years, 16 males, ejection fraction 47 ± 13%) underwent preprocedural cardiac computed tomographic angiography (CTA). In 14 of these patients, the intramural site of origin (SOO) was identified with multipolar catheters. The intramural SOO could not be accessed with mapping catheters in the other 15 patients while mapping the coronary venous system. The CTA identified sizable proximal septal veins in all patients in whom the SOO could be accessed with mapping catheters. In the patients in whom the intramural SOO was not identified, the proximal septal veins were often either small (<2 mm at the branching site) or non-existent (n = 9, p = .001). The proximal septal veins in patients in whom the SOO was identified were larger than in the patients in whom the SOO could not be identified (3.0 ± 0.6 mm vs. 2.1 ± 0.9 mm, p = .01). CONCLUSIONS: Preprocedural imaging with CTAs can be beneficial in identifying the anatomy of proximal septal coronary veins that allow adequate mapping of patients with suspected intramural VAs.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Idoso , Arritmias Cardíacas , Vasos Coronários , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/etiologia , Tomografia Computadorizada por Raios X
2.
J Cardiovasc Electrophysiol ; 33(5): 975-981, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35170146

RESUMO

BACKGROUND: Intramural ventricular arrhythmias (VAs) can originate in patients with or without structural heart disease. Electrogram (EGM) recordings from intramural sources of VA have not been described thoroughly. OBJECTIVE: We hypothesized that the presence of scar may be linked to the site of origin (SOO) of focal, intramural VAs. METHODS: In a series of 21 patients (age: 55 ± 11 years, 12 women, mean ejection fraction 43 ± 14%) in whom the SOO of intramural VAs was identified, we analyzed bipolar EGM characteristics at the SOO and compared the findings with the endocardial breakout site. The patients were from a pool of 86 patients with intramural VAs referred for ablation. RESULTS: In 16/21 patients intramural scarring was detected by cardiac magnetic resonance (CMR) imaging In patients in whom the intramural SOO was reached, intramural bipolar EGMs showed a lower voltage and had broader EGMs compared to the endocardial breakout sites (0.97 ± 0.56 vs. 2.28 ± 0.15 mV, p = .001; and 122.3 ± 31.6 vs. 96.5 ± 26.3 ms, p < .01). All intramural sampled sites at the SOO had either low voltage or broad abnormal EGMs. The activation time was significantly earlier at the intramural SOO than at breakout sites (-36.2 ± 11.8 vs. -23.2 ± 9.1 ms, p < .0001). CONCLUSIONS: Sites of origin of intramural VAs with scar by CMR display EGM characteristics of scarring, supporting that scar tissue localizes to the SOO of intramural outflow tract arrhythmias in some patients. Scarring identified by CMR may be helpful in planning ablation procedures in patients with suspected intramural VAs.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Adulto , Idoso , Arritmias Cardíacas , Cicatriz/patologia , Endocárdio , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/patologia , Taquicardia Ventricular/cirurgia
3.
J Cardiovasc Electrophysiol ; 32(9): 2462-2470, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34258807

RESUMO

BACKGROUND: A combination of endocardial and epicardial approaches has improved the overall success rate of ventricular tachycardia (VT) ablation in patients with cardiomyopathy. However, the origins of some VTs are truly intramural or close to coronary arteries, which makes this combined strategy either prone to failure or too risky. OBJECTIVES: This observational study aimed to explore the feasibility and efficacy of direct epicardial ablation combined with intramural ethanol injection via surgical approach for inaccessible intramural VTs or VTs too close to coronary arteries. METHODS: In four canines ventricular lesions produced by direct epicardial injection of ethanol were assessed. Six consecutive patients with recurrent VT refractory to catheter endocardial and epicardial RF ablation and that remained inducible after surgical epicardial mapping and RF ablation were included. Ethanol was injected by needle at the epicardial RF ablation sites. The primary outcome was freedom of sustained VT determined by device interrogation and periodical 24-h holter recordings subsequently. RESULTS: In an animal study, the lesions were homogenous and increased in size with the volume of ethanol injected. In all six patients, ethanol injection at the target sites in the anterior or lateral left ventricle abolished inducible VT. Over a median follow-up of 22 months (range, 6-65), all patients remained free of sustained VT. One patient died of pulmonary infection one year after the procedure. CONCLUSIONS: A hybrid strategy of surgical ablation combined with intramural ethanol injection is feasible and effective in patients with multiple failed percutaneous ablation attempts.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Animais , Ablação por Cateter/efeitos adversos , Cães , Endocárdio/cirurgia , Mapeamento Epicárdico , Etanol , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Resultado do Tratamento
4.
Am J Emerg Med ; 38(6): 1077-1081, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-31422858

RESUMO

CLINICAL QUESTION: Valsalva maneuver is a recognized treatment for supraventricular tachycardia, but in clinical setting it has a low chance to achieve successful cardioversion. Studies suggested that the postural modification of valsalva maneuver may improve the rate of cardioversion. We further modified the maneuver and conduct a multicenter randomized controlled trial to test its efficacy. RESEARCH IN CONTEXT: Appelboam A, Reuben A, Mann C, et al. Postural modification of the standard Valsalva maneuver for emergency treatment for supraventricular tachycardias (REVERT): a randomized controlled trial. Lancet 2015; 386 (10005):1747-53 [1]. Allison Michaud, PhD, Eddy Lang. Leg lift Valsalva maneuver for treatment of supraventricular tachycardias. CJEM 2017; 19(3):235-237 [2]. OBJECTIVE: To verify the efficacy of the modified Valsalva maneuver in SVT in Chinese population and simplify the operation process further.


Assuntos
Cardioversão Elétrica/métodos , Eletrocardiografia , Tratamento de Emergência/métodos , Frequência Cardíaca/fisiologia , Taquicardia Supraventricular/terapia , Manobra de Valsalva/fisiologia , Adolescente , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/fisiopatologia , Resultado do Tratamento , Adulto Jovem
6.
Front Cardiovasc Med ; 10: 1212837, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37469484

RESUMO

Background: During slow pathway modification for atrioventricular nodal reentrant tachycardia, heart block may occur if ablation cannot be stopped in time in response to high risk electrogram features (HREF). Objectives: To develop an automatic algorithm to monitor HREF and terminate ablation earlier than human reaction. Methods: Digital electrogram data from 332 ablation runs from February 2020 to June 2022 were included. They were divided into training and validation sets which contained 126 and 206 ablation runs respectively. HREF in training set was measured. Then a program was developed with cutoff values decided from training set to capture all these HREF. Simulation ablation videos were rendered using validation set electrogram data. The videos were played to three independent electrophysiologists who each determined when to stop ablation. Timing of ablation termination, sensitivity, and specificity were compared between human and program. Results: Reasons for ablation termination in the training set include short AA time, short VV time, AV block and VA block. Cutoffs for the program were set to maximize program sensitivity. Sensitivity and specificity for the program in the validation set were 95.2% and 91.1% respectively, which were comparable to that of human performance at 93.5% and 95.4%. If HREF were recognized by both human and program, ablations were terminated earlier by the program 90.2% of times, by a median of 574 ms (interquartile range 412-807 ms, p < 0.001). Conclusion: Algorithmic-driven monitoring of slow pathway modification can supplement human judgement to improve ablation safety.

7.
Langmuir ; 26(6): 4506-13, 2010 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-20000630

RESUMO

The poly(4-vinyl pyridine) (P4VP)-brush-modified indium tin oxide (ITO) electrode was used to switch reversibly the interfacial activity by the electrochemical signal. The application of an external potential (-0.85 V vs Ag|AgCl|KCl, 3M) that electrochemically reduced O(2) resulted in the concomitant consumption of hydrogen ions at the electrode interface, thus yielding a higher pH value and triggering the restructuring of the P4VP brush on the electrode surface. The initial swollen state of the protonated P4VP brush (pH 4.4) was permeable to the anionic [Fe(CN)(6)](4-) redox species, but the electrochemically produced local pH of 9.1 resulted in the deprotonation of the polymer brush. The produced hydrophobic shrunken state of the polymer brush was impermeable to the anionic redox species, thus fully inhibiting its redox process at the electrode surface. The interface's return to the electrochemically active state was achieved by disconnecting the applied potential, followed by stirring the electrolyte solution or by slow diffusional exchange of the electrode-adjacent thin layer with the bulk solution. The developed approach allowed the electrochemically triggered inhibition ("closing") of the electrode interface. The application of this approach to different interfacial systems will allow the use of various switchable electrodes that are useful for biosensors and biofuel cells with externally controlled activity. Further use of this concept was suggested for electrochemically controlled chemical actuators (e.g. operating as electroswitchable drug releasers).


Assuntos
Eletrodos , Polímeros , Concentração de Íons de Hidrogênio , Microscopia de Força Atômica , Oxirredução
8.
J Am Chem Soc ; 131(3): 1314-21, 2009 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-19113843

RESUMO

The logic network composed of three enzymes (alcohol dehydrogenase, glucose dehydrogenase, and glucose oxidase) operating in concert as four concatenated logic gates (AND/OR), was designed to process four different chemical input signals (NADH, acetaldehyde, glucose, and oxygen). The cascade of biochemical reactions culminated in pH changes controlled by the pattern of the applied biochemical input signals. The "successful" set of inputs produced gluconic acid as the final product and yielded an acidic medium, lowering the pH of a solution from its initial value of pH 6-7 to the final value of ca. 4. The whole set of the input signal combinations included 16 variants resulting in different output signals. Those that corresponded to the logic output 1, according to the Boolean logic encoded in the logic circuitry, resulted in the acidic medium. The pH changes produced in situ were coupled with a pH-sensitive polymer-brush-functionalized electrode, resulting in the interface switching from the OFF state, when the electrochemical reactions are inhibited, to the ON state, when the interface is electrochemically active. Soluble [Fe(CN)(6)](3-/4-) was used as an external redox probe to analyze the state of the interface and to follow the changes produced in situ by the enzyme logic network, depending on the pattern of the applied biochemical signals. The chemical signals processed by the enzyme logic system and transduced by the sensing interface were read out by electrochemical means (cyclic voltammetry and Faradaic impedance spectroscopy). This readout step features a "sigmoid" processing of the signals that provides "filtering" and significantly suppresses errors. Coupling between signal-processing enzyme logic networks and electronic transducers will allow future "smart" bioelectronic devices to respond to immediate physiological changes and provide autonomous signaling/actuation depending on the concentration patterns of the physiological markers.


Assuntos
Álcool Desidrogenase/química , Técnicas Biossensoriais/métodos , Eletrodos , Glucose 1-Desidrogenase/química , Glucose Oxidase/química , Álcool Desidrogenase/metabolismo , Biocatálise , Glucose 1-Desidrogenase/metabolismo , Glucose Oxidase/metabolismo , Concentração de Íons de Hidrogênio , Modelos Moleculares , Estrutura Terciária de Proteína
9.
J Am Chem Soc ; 131(33): 11670-1, 2009 Aug 26.
Artigo em Inglês | MEDLINE | ID: mdl-19673516

RESUMO

A switchable biofuel cell logically controlled by immune signals was developed as a model prototype for future adaptive implantable bioelectronic devices regulated by immune reactions. The cell demonstrated NOR Boolean logic operation in situ controlled by antibody signals.


Assuntos
Anticorpos/imunologia , Antígenos/imunologia , Fontes de Energia Bioelétrica , Lógica , Animais , Bovinos , Concentração de Íons de Hidrogênio
10.
J Am Chem Soc ; 131(2): 826-32, 2009 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-19105750

RESUMO

An enzyme-based biofuel cell with a pH-switchable oxygen electrode, controlled by enzyme logic operations processing in situ biochemical input signals, has been developed. Two Boolean logic gates (AND/OR) were assembled from enzyme systems to process biochemical signals and to convert them logically into pH-changes of the solution. The cathode used in the biofuel cell was modified with a polymer-brush functionalized with Os-complex redox species operating as relay units to mediate electron transport between the conductive support and soluble laccase biocatalyzing oxygen reduction. The electrochemical activity of the modified electrode was switchable by alteration of the solution pH value. The electrode was electrochemically mute at pH > 5.5, and it was activated for the bioelectrocatalytic oxygen reduction at pH < 4.5. The sharp transition between the inactive and active states was used to control the electrode activity by external enzymatic systems operating as logic switches in the system. The enzyme logic systems were decreasing the pH value upon appropriate combinations of the biochemical signals corresponding to the AND/OR Boolean logic. Then the pH-switchable electrode was activated for the oxygen reduction, and the entire biofuel cell was switched ON. The biofuel cell was also switched OFF by another biochemical signal which resets the pH value to the original neutral value. The present biofuel cell is the first prototype of a future implantable biofuel cell controlled by complex biochemical reactions to deliver power on-demand responding in a logical way to the physiological needs.


Assuntos
Fontes de Energia Bioelétrica , Enzimas/química , Lógica , Animais , Técnicas Biossensoriais/métodos , Esterases/química , Glucana 1,4-alfa-Glucosidase/química , Glucose 1-Desidrogenase/química , Glucose Oxidase/química , Lacase/química , Oxigênio/química , Suínos , Urease/química
11.
Nanotechnology ; 20(43): 434006, 2009 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-19801770

RESUMO

A pH-responsive mixed polyelectrolyte brush from tethered polyacrylic acid (PAA) and poly(2-vinylpyridine) (P2VP) (PAA:P2VP = 69:31 by weight) was prepared and used for selective gating transport of anions and cations across the thin film. An ITO glass electrode was modified with the polymer brush and used to study the switchable permeability of the mixed brush triggered by changes in pH of the aqueous environment in the presence of two soluble redox probes: [Fe(CN)(6)](4-) and [Ru(NH(3))(6)](3+). The responsive behavior of the brush was also investigated using the in situ ellipsometric measurements of the brush swelling, examination of the brush morphology with atomic force microscopy (AFM), and contact angle measurements of the brush samples extracted from aqueous solutions at different pH values. The mixed brush demonstrated a bipolar permselective behavior. At pH<3 the positively charged P2VP chains enabled the electrochemical process for the negatively charged redox probe, [Fe(CN)(6)](4-), while the redox process for the positively charged redox probe was effectively inhibited. On the contrary, at pH>6 a reversible redox process for the positively charged redox probe, [Ru(NH(3))(6)](3+), was observed, while the redox process for the negatively charged redox species, [Fe(CN)(6)](4-), was fully inhibited. Stepwise changing the pH value and recording cyclic voltammograms for the intermediate states of the polymer brush allowed electrochemical observation of the brush transition from the positively charged state, permeable for the negatively charged species, to the negatively charged state, permeable for the positively charged species. The data of ellipsometric, AFM and contact angle measurements are in accord with the electrochemical study. The discovered properties of the brush could be used for the development of 'smart' sensors and drug delivery systems, for example, a smart drug delivery capsule which could release negatively charged molecules of drugs in acidic conditions, while positively charged molecules of drugs will be released in neutral conditions.


Assuntos
Resinas Acrílicas/química , Íons/química , Polivinil/química , Sistemas de Liberação de Medicamentos , Eletroquímica , Concentração de Íons de Hidrogênio
14.
Adv Biochem Eng Biotechnol ; 137: 125-52, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23748347

RESUMO

: Increasing needs of green energy and concerns of climate change are motivating intensive R&D efforts toward the low-cost production of electricity and bioenergy, such as hydrogen, alcohols, and jet fuel, from renewable sugars. Cell-free biosystems for biomanufacturing (CFB2) have been suggested as an emerging platform to replace mainstream microbial fermentation for the cost-effective production of some biocommodities. As compared to whole-cell factories, cell-free biosystems comprised of synthetic enzymatic pathways have numerous advantages, such as high product yield, fast reaction rate, broad reaction condition, easy process control and regulation, tolerance of toxic compound/product, and an unmatched capability of performing unnatural reactions. However, issues pertaining to high costs and low stabilities of enzymes and cofactors as well as compromised optimal conditions for different source enzymes need to be solved before cell-free biosystems are scaled up for biomanufacturing. Here, we review the current status of cell-free technology, update recent advances, and focus on its applications in the production of electricity and bioenergy.


Assuntos
Mudança Climática , Eletricidade , Álcoois , Fontes de Energia Bioelétrica , Fermentação , Hidrogênio/metabolismo
15.
Bioelectrochemistry ; 86: 92-6, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22497727

RESUMO

NAD/NADH is a coenzyme found in all living cells, carrying electrons from one reaction to another. We report on characterizations of in situ regeneration of NADH via lipoamide dehydrogenase (LD)-catalyzed electron transfer reaction to regenerate NADH using UV-vis spectroelectrochemistry. The Michaelis-Menten constant (K(m)) and maximum velocity (V(max)) of NADH regeneration were measured as 0.80±0.15 mM and 1.91±0.09 µM s(-1) in a 1-mm thin-layer spectroelectrochemical cell using gold gauze as the working electrode at the applied potential -0.75 V (vs. Ag/AgCl). The electrocatalytic reduction of the NAD system was further coupled with the enzymatic conversion of pyruvate to lactate by lactate dehydrogenase to examine the coenzymatic activity of the regenerated NADH. Although the reproducible electrocatalytic reduction of NAD into NADH is known to be difficult compared to the electrocatalytic oxidation of NADH, our spectroelectrochemical results indicate that the in situ regeneration of NADH via LD-catalyzed electron transfer reaction is fast and sustainable and can be potentially applied to many NAD/NADH-dependent enzyme systems.


Assuntos
Di-Hidrolipoamida Desidrogenase/metabolismo , NAD/metabolismo , Espectrofotometria Ultravioleta/métodos , Di-Hidrolipoamida Desidrogenase/química , Técnicas Eletroquímicas , Eletrodos , Transporte de Elétrons , Lactatos/química , Lactatos/metabolismo , NAD/química , Ácido Pirúvico/química , Ácido Pirúvico/metabolismo , Espectrofotometria Ultravioleta/instrumentação
16.
ACS Appl Mater Interfaces ; 3(5): 1620-3, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21452844

RESUMO

Biomarkers characteristic of liver injury, alanine transaminase and lactate dehydrogenase, were processed by an enzyme-based system functioning as a logic AND gate. The NAD+ output signal produced by the system upon its activation in the presence of both biomarkers was then biocatalytically converted to a decrease in pH. The acidic pH value biocatalytically produced by the system as a response to the biomarkers triggered the restructuring of a polymer-modified electrode interface. This allowed a soluble redox species to approach the electrode surface, thus switching the electrochemical reaction ON. The redox transformations activated by the biochemical signals resulted in an amplification of signals. This system represents the first example of an integrated sensing-actuating chemical device with the implemented AND Boolean logic for processing natural biomarkers at their physiologically relevant concentrations.


Assuntos
Biomarcadores/análise , Técnicas Biossensoriais/métodos , Técnicas Eletroquímicas/métodos , Alanina Transaminase/metabolismo , Concentração de Íons de Hidrogênio , L-Lactato Desidrogenase/metabolismo , NAD/metabolismo
17.
Chem Commun (Camb) ; 47(11): 3060-2, 2011 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-21203618

RESUMO

We developed a bacteria-based AND logic gate using a Pseudomonas aeruginosa lasI/rhlI double mutant with two quorum-sensing signaling molecules as the input signals. We showed a distinct electrical output signal, despite the complexity and continuous regulation of metabolic reactions of living cells.


Assuntos
Pseudomonas aeruginosa/metabolismo , 4-Butirolactona/análogos & derivados , 4-Butirolactona/química , Proteínas de Bactérias/química , Proteínas de Bactérias/genética , Proteínas de Bactérias/metabolismo , Técnicas Biossensoriais , Técnicas Eletroquímicas , Eletrodos , Ligases/química , Ligases/genética , Ligases/metabolismo , Mutação , Fenazinas/química , Percepção de Quorum/fisiologia , Fatores de Transcrição/química , Fatores de Transcrição/genética , Fatores de Transcrição/metabolismo
18.
Chem Commun (Camb) ; 46(12): 2088-90, 2010 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-20221501

RESUMO

A nanostructured biocatalytic interface reversibly gating electrochemical reactions upon chemical signals processed by immobilized enzymes was architectured. The chemical signals were converted to local interfacial pH changes causing restructuring of the stimuli-responsive polymer and switching ON-OFF the electrochemical reaction.


Assuntos
Enzimas/metabolismo , Nanoestruturas , Biocatálise , Eletroquímica , Concentração de Íons de Hidrogênio
19.
Chem Commun (Camb) ; 46(14): 2405-7, 2010 Apr 14.
Artigo em Inglês | MEDLINE | ID: mdl-20379542

RESUMO

The enzyme-based keypad lock was integrated with a biofuel cell yielding a self-powered biomolecular information security system. The correct "password" introduced into the keypad lock resulted in the activation of the biofuel cell, while all other "wrong" permutations of the enzyme inputs preserved the "OFF" state of the biofuel cell.


Assuntos
Enzimas Imobilizadas/química , Biocatálise , Fontes de Energia Bioelétrica , Eletrodos , Concentração de Íons de Hidrogênio , Oxirredução , Polímeros/química
20.
Bioelectrochemistry ; 76(1-2): 4-9, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19351582

RESUMO

A "smart" biofuel cell switchable ON and OFF upon application of several chemical signals processed by an enzyme logic network was designed. The biocomputing system performing logic operations on the input signals was composed of four enzymes: alcohol dehydrogenase (ADH), amyloglucosidase (AGS), invertase (INV) and glucose dehydrogenase (GDH). These enzymes were activated by different combinations of chemical input signals: NADH, acetaldehyde, maltose and sucrose. The sequence of biochemical reactions catalyzed by the enzymes models a logic network composed of concatenated AND/OR gates. Upon application of specific "successful" patterns of the chemical input signals, the cascade of biochemical reactions resulted in the formation of gluconic acid, thus producing acidic pH in the solution. This resulted in the activation of a pH-sensitive redox-polymer-modified cathode in the biofuel cell, thus, switching ON the entire cell and dramatically increasing its power output. Application of another chemical signal (urea in the presence of urease) resulted in the return to the initial neutral pH value, when the O(2)-reducing cathode and the entire cell are in the mute state. The reversible activation-inactivation of the biofuel cell was controlled by the enzymatic reactions logically processing a number of chemical input signals applied in different combinations. The studied biofuel cell exemplifies a new kind of bioelectronic device where the bioelectronic function is controlled by a biocomputing system. Such devices will provide a new dimension in bioelectronics and biocomputing benefiting from the integration of both concepts.


Assuntos
Fontes de Energia Bioelétrica , Eletroquímica/instrumentação , Enzimas/metabolismo , Lógica , Álcool Desidrogenase/metabolismo , Bactérias/enzimologia , Biocatálise , Fontes de Energia Bioelétrica/microbiologia , Eletrodos , Fungos/enzimologia , Glucana 1,4-alfa-Glucosidase/metabolismo , Gluconatos/metabolismo , Glucose/química , Glucose/metabolismo , Glucose 1-Desidrogenase/metabolismo , Concentração de Íons de Hidrogênio , Modelos Moleculares , Oxirredução , Conformação Proteica , beta-Frutofuranosidase/metabolismo
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa