RESUMO
BACKGROUND: Patients with severe aortic stenosis and a small aortic annulus are at risk for impaired valvular hemodynamic performance and associated adverse cardiovascular clinical outcomes after transcatheter aortic-valve replacement (TAVR). METHODS: We randomly assigned patients with symptomatic severe aortic stenosis and an aortic-valve annulus area of 430 mm2 or less in a 1:1 ratio to undergo TAVR with either a self-expanding supraannular valve or a balloon-expandable valve. The coprimary end points, each assessed through 12 months, were a composite of death, disabling stroke, or rehospitalization for heart failure (tested for noninferiority) and a composite end point measuring bioprosthetic-valve dysfunction (tested for superiority). RESULTS: A total of 716 patients were treated at 83 sites in 13 countries (mean age, 80 years; 87% women; mean Society of Thoracic Surgeons Predicted Risk of Mortality, 3.3%). The Kaplan-Meier estimate of the percentage of patients who died, had a disabling stroke, or were rehospitalized for heart failure through 12 months was 9.4% with the self-expanding valve and 10.6% with the balloon-expandable valve (difference, -1.2 percentage points; 90% confidence interval [CI], -4.9 to 2.5; P<0.001 for noninferiority). The Kaplan-Meier estimate of the percentage of patients with bioprosthetic-valve dysfunction through 12 months was 9.4% with the self-expanding valve and 41.6% with the balloon-expandable valve (difference, -32.2 percentage points; 95% CI, -38.7 to -25.6; P<0.001 for superiority). The aortic-valve mean gradient at 12 months was 7.7 mm Hg with the self-expanding valve and 15.7 mm Hg with the balloon-expandable valve, and the corresponding values for additional secondary end points through 12 months were as follows: mean effective orifice area, 1.99 cm2 and 1.50 cm2; percentage of patients with hemodynamic structural valve dysfunction, 3.5% and 32.8%; and percentage of women with bioprosthetic-valve dysfunction, 10.2% and 43.3% (all P<0.001). Moderate or severe prosthesis-patient mismatch at 30 days was found in 11.2% of the patients in the self-expanding valve group and 35.3% of those in the balloon-expandable valve group (P<0.001). Major safety end points appeared to be similar in the two groups. CONCLUSIONS: Among patients with severe aortic stenosis and a small aortic annulus who underwent TAVR, a self-expanding supraannular valve was noninferior to a balloon-expandable valve with respect to clinical outcomes and was superior with respect to bioprosthetic-valve dysfunction through 12 months. (Funded by Medtronic; SMART ClinicalTrials.gov number, NCT04722250.).
Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Bioprótese/efeitos adversos , Insuficiência Cardíaca , Estimativa de Kaplan-Meier , Complicações Pós-Operatórias/etiologia , Desenho de Prótese , Falha de Prótese , Acidente Vascular Cerebral/etiologia , Substituição da Valva Aórtica Transcateter/efeitos adversosRESUMO
BACKGROUND AND AIMS: The length of stay (LOS) after transcatheter aortic valve implantation (TAVI) remains extremely variable whereas early discharge has been shown to be feasible and safe. The study objective was to evaluate the efficacy and safety of an intervention aimed at reducing LOS after transfemoral TAVI. METHODS: FAST-TAVI II is a prospective, multicentre, cluster, randomized, controlled study including patients with severe symptomatic aortic stenosis, who had transfemoral TAVI. The intervention consisted in a dedicated training programme to implement 10 quality of care measures to reduce LOS with an implementation phase of eight weeks. The primary endpoint was the proportion of patients discharged early within 3 days. Secondary endpoints included: LOS, 30-day mortality and 30-day incidence of readmission for cardiovascular events. RESULTS: During the study period, 969 patients were enrolled in the intervention group and 860 patients in the control group. Mean age was 81.9 ± 6.6 years and mean EuroSCORE II was 4.4 ± 4.5%. Early discharge was achieved in 563 (58.1%) patients in the intervention group vs. 364 (42.3%) patients in the control group (P < .0001). Median LOS was significantly reduced in the intervention group compared to the control group [3 (IQR: 3) vs. 4 days (IQR: 3), P < .0001]. Thirty-day mortality was low and similar in the two groups (0.5% vs. 0.9%, P = .30), as were 30-day readmissions (4.6% vs. 2.8%, P = .28). CONCLUSIONS: The intervention was simple and fast to implement, and was effective and safe to reduce LOS and increase the proportion of patients discharged early after TAVI (NCT04503655).
Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/cirurgia , Tempo de Internação , Estudos Prospectivos , Alta do Paciente , Resultado do Tratamento , Valva Aórtica/cirurgia , Fatores de RiscoRESUMO
BACKGROUND AND AIMS: This trial sought to assess the safety and efficacy of ShortCut, the first dedicated leaflet modification device, prior to transcatheter aortic valve implantation (TAVI) in patients at risk for coronary artery obstruction. METHODS: This pivotal prospective study enrolled patients with failed bioprosthetic aortic valves scheduled to undergo TAVI and were at risk for coronary artery obstruction. The primary safety endpoint was procedure-related mortality or stroke at discharge or 7 days, and the primary efficacy endpoint was per-patient leaflet splitting success. Independent angiographic, echocardiographic, and computed tomography core laboratories assessed all images. Safety events were adjudicated by a clinical events committee and data safety monitoring board. RESULTS: Sixty eligible patients were treated (77.0 ± 9.6 years, 70% female, 96.7% failed surgical bioprosthetic valves, 63.3% single splitting and 36.7% dual splitting) at 22 clinical sites. Successful leaflet splitting was achieved in all [100%; 95% confidence interval (CI) 94%-100.0%, P < .001] patients. Procedure time, including imaging confirmation of leaflet splitting, was 30.6 ± 17.9â min. Freedom from the primary safety endpoint was achieved in 59 [98.3%; 95% CI (91.1%-100%)] patients, with no mortality and one (1.7%) disabling stroke. At 30 days, freedom from coronary obstruction was 95% (95% CI 86.1%-99.0%). Within 90 days, freedom from mortality was 95% [95% CI (86.1%-99.0%)], without any cardiovascular deaths. CONCLUSIONS: Modification of failed bioprosthetic aortic valve leaflets using ShortCut was safe, achieved successful leaflet splitting in all patients, and was associated with favourable clinical outcomes in patients at risk for coronary obstruction undergoing TAVI.
Assuntos
Estenose da Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Substituição da Valva Aórtica Transcateter/métodos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Masculino , Idoso , Estudos Prospectivos , Estenose da Valva Aórtica/cirurgia , Falha de Prótese , Desenho de Prótese , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Resultado do Tratamento , Oclusão Coronária/cirurgia , Complicações Pós-Operatórias/epidemiologiaRESUMO
INTRODUCTION: Bicuspid aortic valve (BAV) stenosis is a complex anatomical scenario for transcatheter aortic valve implantation (TAVI). Favorable short-term clinical outcomes have been reported with TAVI in this setting, but long-term data are scarce. METHODS: We retrospectively included, in a single-center registry, patients with BAV stenosis who underwent TAVI before 2020. We compared patients treated with self-expanding valves (SEV) versus balloon-expandable valves (BEV). The primary endpoint was a composite of all-cause mortality, stroke and need for aortic valve (AV) reintervention at 3 years. Secondary endpoints included each component of the primary endpoint, cardiovascular mortality, permanent pacemaker implantation (PPI) rate, mean gradient and ≥moderate paravalvular leak (PVL) rate. RESULTS: A total of 150 consecutive patients (SEV = 83, BEV = 67) were included. No significant differences were reported between SEV and BEV groups for the primary composite endpoint (SEV 35.9% vs. BEV 32%, p = 0.66), neither for clinical secondary endpoints (all-cause mortality SEV 28.1% vs. BEV 28%, p = 0.988; cardiovascular mortality SEV 14.1% vs. BEV 20%, p = 0.399; stroke SEV 12.5% vs. BEV 6%, p = 0.342; need for AV reintervention SEV 0% vs. BEV 0%; PPI SEV 28.1% vs. BEV 24%, p = 0.620). A lower mean gradient persisted up to 3 years in the SEV group (SEV 8.8 ± 3.8 mmHg vs. BEV 10.7 ± 3.2 mmHg, p = 0.063), while no significant difference was found in the rate of ≥ moderate PVL (SEV 3/30 vs. BEV 0/25, p = 0.242). CONCLUSIONS: In this single center registry, we observed favorable 3-year clinical outcomes in nonselected BAV patients treated with different generation devices, without significant differences between patients receiving SEV or BEV.
Assuntos
Estenose da Valva Aórtica , Valvuloplastia com Balão , Doença da Válvula Aórtica Bicúspide , Próteses Valvulares Cardíacas , Desenho de Prótese , Sistema de Registros , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/mortalidade , Masculino , Feminino , Estudos Retrospectivos , Resultado do Tratamento , Doença da Válvula Aórtica Bicúspide/fisiopatologia , Doença da Válvula Aórtica Bicúspide/diagnóstico por imagem , Doença da Válvula Aórtica Bicúspide/mortalidade , Doença da Válvula Aórtica Bicúspide/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/mortalidade , Fatores de Tempo , Idoso , Valvuloplastia com Balão/efeitos adversos , Valvuloplastia com Balão/mortalidade , Idoso de 80 Anos ou mais , Fatores de Risco , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Valva Aórtica/fisiopatologia , Valva Aórtica/anormalidades , Recuperação de Função Fisiológica , Hemodinâmica , Medição de RiscoRESUMO
BACKGROUND AND AIMS: For patients with symptomatic, severe tricuspid regurgitation (TR), early results of transcatheter tricuspid valve (TV) intervention studies have shown significant improvements in functional status and quality of life associated with right-heart reverse remodelling. Longer-term follow-up is needed to confirm sustained improvements in these outcomes. METHODS: The prospective, single-arm, multicentre TRISCEND study enrolled 176 patients to evaluate the safety and performance of transcatheter TV replacement in patients with ≥moderate, symptomatic TR despite medical therapy. Major adverse events, reduction in TR grade and haemodynamic outcomes by echocardiography, and clinical, functional, and quality-of-life parameters are reported to one year. RESULTS: Enrolled patients were 71.0% female, mean age 78.7 years, 88.0% ≥ severe TR, and 75.4% New York Heart Association classes III-IV. Tricuspid regurgitation was reduced to ≤mild in 97.6% (P < .001), with increases in stroke volume (10.5 ± 16.8â mL, P < .001) and cardiac output (0.6 ± 1.2â L/min, P < .001). New York Heart Association class I or II was achieved in 93.3% (P < .001), Kansas City Cardiomyopathy Questionnaire score increased by 25.7 points (P < .001), and six-minute walk distance increased by 56.2â m (P < .001). All-cause mortality was 9.1%, and 10.2% of patients were hospitalized for heart failure. CONCLUSIONS: In an elderly, highly comorbid population with ≥moderate TR, patients receiving transfemoral EVOQUE transcatheter TV replacement had sustained TR reduction, significant increases in stroke volume and cardiac output, and high survival and low hospitalization rates with improved clinical, functional, and quality-of-life outcomes to one year. Funded by Edwards Lifesciences, TRISCEND ClinicalTrials.gov number, NCT04221490.
Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Humanos , Feminino , Idoso , Masculino , Insuficiência da Valva Tricúspide/epidemiologia , Insuficiência da Valva Tricúspide/cirurgia , Valva Tricúspide/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Estudos Prospectivos , Qualidade de Vida , Resultado do Tratamento , Cateterismo Cardíaco/métodos , Índice de Gravidade de DoençaRESUMO
BACKGROUND: Whether the direct factor Xa inhibitor rivaroxaban can prevent thromboembolic events after transcatheter aortic-valve replacement (TAVR) is unclear. METHODS: We randomly assigned 1644 patients without an established indication for oral anticoagulation after successful TAVR to receive rivaroxaban at a dose of 10 mg daily (with aspirin at a dose of 75 to 100 mg daily for the first 3 months) (rivaroxaban group) or aspirin at a dose of 75 to 100 mg daily (with clopidogrel at a dose of 75 mg daily for the first 3 months) (antiplatelet group). The primary efficacy outcome was the composite of death or thromboembolic events. The primary safety outcome was major, disabling, or life-threatening bleeding. The trial was terminated prematurely by the data and safety monitoring board because of safety concerns. RESULTS: After a median of 17 months, death or a first thromboembolic event (intention-to-treat analysis) had occurred in 105 patients in the rivaroxaban group and in 78 patients in the antiplatelet group (incidence rates, 9.8 and 7.2 per 100 person-years, respectively; hazard ratio with rivaroxaban, 1.35; 95% confidence interval [CI], 1.01 to 1.81; P = 0.04). Major, disabling, or life-threatening bleeding (intention-to-treat analysis) had occurred in 46 and 31 patients, respectively (4.3 and 2.8 per 100 person-years; hazard ratio, 1.50; 95% CI, 0.95 to 2.37; P = 0.08). A total of 64 deaths occurred in the rivaroxaban group and 38 in the antiplatelet group (5.8 and 3.4 per 100 person-years, respectively; hazard ratio, 1.69; 95% CI, 1.13 to 2.53). CONCLUSIONS: In patients without an established indication for oral anticoagulation after successful TAVR, a treatment strategy including rivaroxaban at a dose of 10 mg daily was associated with a higher risk of death or thromboembolic complications and a higher risk of bleeding than an antiplatelet-based strategy. (Funded by Bayer and Janssen Pharmaceuticals; GALILEO ClinicalTrials.gov number, NCT02556203.).
Assuntos
Aspirina/uso terapêutico , Clopidogrel/uso terapêutico , Inibidores do Fator Xa/uso terapêutico , Inibidores da Agregação Plaquetária/uso terapêutico , Rivaroxabana/uso terapêutico , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Aspirina/efeitos adversos , Fibrilação Atrial/tratamento farmacológico , Doenças Cardiovasculares/mortalidade , Clopidogrel/efeitos adversos , Quimioterapia Combinada , Inibidores do Fator Xa/efeitos adversos , Feminino , Próteses Valvulares Cardíacas , Hemorragia/induzido quimicamente , Humanos , Análise de Intenção de Tratamento , Estimativa de Kaplan-Meier , Masculino , Inibidores da Agregação Plaquetária/efeitos adversos , Rivaroxabana/efeitos adversos , Tromboembolia/mortalidadeRESUMO
BACKGROUND: Mitral valve-in-valve (ViV) and valve-in-ring (ViR) are alternatives to surgical reoperation in patients with recurrent mitral valve failure after previous surgical valve repair or replacement. Our aim was to perform a large-scale analysis examining midterm outcomes after mitral ViV and ViR. METHODS: Patients undergoing mitral ViV and ViR were enrolled in the Valve-in-Valve International Data Registry. Cases were performed between March 2006 and March 2020. Clinical endpoints are reported according to the Mitral Valve Academic Research Consortium (MVARC) definitions. Significant residual mitral stenosis (MS) was defined as mean gradient ≥10 mm Hg and significant residual mitral regurgitation (MR) as ≥ moderate. RESULTS: A total of 1079 patients (857 ViV, 222 ViR; mean age 73.5±12.5 years; 40.8% male) from 90 centers were included. Median STS-PROM score 8.6%; median clinical follow-up 492 days (interquartile range, 76-996); median echocardiographic follow-up for patients that survived 1 year was 772.5 days (interquartile range, 510-1211.75). Four-year Kaplan-Meier survival rate was 62.5% in ViV versus 49.5% for ViR (P<0.001). Mean gradient across the mitral valve postprocedure was 5.7±2.8 mm Hg (≥5 mm Hg; 61.4% of patients). Significant residual MS occurred in 8.2% of the ViV and 12.0% of the ViR patients (P=0.09). Significant residual MR was more common in ViR patients (16.6% versus 3.1%; P<0.001) and was associated with lower survival at 4 years (35.1% versus 61.6%; P=0.02). The rates of Mitral Valve Academic Research Consortium-defined device success were low for both procedures (39.4% total; 32.0% ViR versus 41.3% ViV; P=0.01), mostly related to having postprocedural mean gradient ≥5 mm Hg. Correlates for residual MS were smaller true internal diameter, younger age, and larger body mass index. The only correlate for residual MR was ViR. Significant residual MS (subhazard ratio, 4.67; 95% CI, 1.74-12.56; P=0.002) and significant residual MR (subhazard ratio, 7.88; 95% CI, 2.88-21.53; P<0.001) were both independently associated with repeat mitral valve replacement. CONCLUSIONS: Significant residual MS and/or MR were not infrequent after mitral ViV and ViR procedures and were both associated with a need for repeat valve replacement. Strategies to improve postprocedural hemodynamics in mitral ViV and ViR should be further explored.
Assuntos
Doenças das Valvas Cardíacas/cirurgia , Próteses Valvulares Cardíacas/normas , Valva Mitral/cirurgia , Sistema de Registros , Reoperação/normas , Substituição da Valva Aórtica Transcateter/normas , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Doenças das Valvas Cardíacas/diagnóstico por imagem , Próteses Valvulares Cardíacas/tendências , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/tendências , Humanos , Internacionalidade , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Reoperação/tendências , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/tendênciasRESUMO
BACKGROUND: Infective endocarditis (IE) following transcatheter aortic valve replacement (TAVR) has been associated with a dismal prognosis. However, scarce data exist on IE perivalvular extension (PEE) in such patients. METHODS: This multicenter study included 579 patients who had the diagnosis of definite IE at a median of 171 (53-421) days following TAVR. PEE was defined as the presence of an intracardiac abscess, pseudoaneurysm, or fistula. RESULTS: A total of 105 patients (18.1%) were diagnosed with PEE (perivalvular abscess, pseudoaneurysm, fistula, or a combination in 87, 7, 7, and 4 patients, respectively). A history of chronic kidney disease (adjusted odds ratio [ORadj], 2.08; 95% confidence interval [CI]: 1.27-3.41; Pâ =â .003) and IE secondary to coagulase-negative staphylococci (ORadj, 2.71; 95% CI: 1.57-4.69; Pâ <â .001) were associated with an increased risk of PEE. Surgery was performed at index IE episode in 34 patients (32.4%) with PEE (vs 15.2% in patients without PEE, Pâ <â .001). In-hospital and 2-year mortality rates among PEE-IE patients were 36.5% and 69.4%, respectively. Factors independently associated with an increased mortality were the occurrence of other complications (stroke post-TAVR, acute renal failure, septic shock) and the lack of surgery at index IE hospitalization (padjâ <â 0.05 for all). CONCLUSIONS: PEE occurred in about one-fifth of IE post-TAVR patients, with the presence of coagulase-negative staphylococci and chronic kidney disease determining an increased risk. Patients with PEE-IE exhibited high early and late mortality rates, and surgery during IE hospitalization seemed to be associated with better outcomes.
Assuntos
Falso Aneurisma , Endocardite Bacteriana , Endocardite , Insuficiência Renal Crônica , Substituição da Valva Aórtica Transcateter , Abscesso , Falso Aneurisma/complicações , Falso Aneurisma/cirurgia , Coagulase , Endocardite/epidemiologia , Endocardite/etiologia , Endocardite/cirurgia , Endocardite Bacteriana/epidemiologia , Endocardite Bacteriana/etiologia , Endocardite Bacteriana/cirurgia , Humanos , Insuficiência Renal Crônica/complicações , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversosAssuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Desenho de Prótese , Substituição da Valva Aórtica Transcateter/instrumentação , Aorta Torácica/anatomia & histologia , Estudos de Equivalência como Asunto , Ventrículos do Coração/anatomia & histologiaRESUMO
BACKGROUND: Transcatheter aortic-valve replacement (TAVR) is an alternative to surgery in patients with severe aortic stenosis who are at increased risk for death from surgery; less is known about TAVR in low-risk patients. METHODS: We performed a randomized noninferiority trial in which TAVR with a self-expanding supraannular bioprosthesis was compared with surgical aortic-valve replacement in patients who had severe aortic stenosis and were at low surgical risk. When 850 patients had reached 12-month follow-up, we analyzed data regarding the primary end point, a composite of death or disabling stroke at 24 months, using Bayesian methods. RESULTS: Of the 1468 patients who underwent randomization, an attempted TAVR or surgical procedure was performed in 1403. The patients' mean age was 74 years. The 24-month estimated incidence of the primary end point was 5.3% in the TAVR group and 6.7% in the surgery group (difference, -1.4 percentage points; 95% Bayesian credible interval for difference, -4.9 to 2.1; posterior probability of noninferiority >0.999). At 30 days, patients who had undergone TAVR, as compared with surgery, had a lower incidence of disabling stroke (0.5% vs. 1.7%), bleeding complications (2.4% vs. 7.5%), acute kidney injury (0.9% vs. 2.8%), and atrial fibrillation (7.7% vs. 35.4%) and a higher incidence of moderate or severe aortic regurgitation (3.5% vs. 0.5%) and pacemaker implantation (17.4% vs. 6.1%). At 12 months, patients in the TAVR group had lower aortic-valve gradients than those in the surgery group (8.6 mm Hg vs. 11.2 mm Hg) and larger effective orifice areas (2.3 cm2 vs. 2.0 cm2). CONCLUSIONS: In patients with severe aortic stenosis who were at low surgical risk, TAVR with a self-expanding supraannular bioprosthesis was noninferior to surgery with respect to the composite end point of death or disabling stroke at 24 months. (Funded by Medtronic; ClinicalTrials.gov number, NCT02701283.).
Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Bioprótese , Implante de Prótese de Valva Cardíaca/métodos , Próteses Valvulares Cardíacas , Desenho de Prótese , Acidente Vascular Cerebral/etiologia , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Insuficiência da Valva Aórtica/etiologia , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/mortalidade , Fibrilação Atrial/etiologia , Teorema de Bayes , Ecocardiografia , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Estimativa de Kaplan-Meier , Tempo de Internação , Masculino , Complicações Pós-Operatórias/epidemiologia , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversosRESUMO
BACKGROUND: The SMall Annuli Randomized To Evolut or SAPIEN (SMART) Trial was designed to compare the performance of the two most widely available commercial transcatheter aortic valve replacement (TAVR) devices in patients with symptomatic severe native aortic stenosis with a small aortic valve annulus undergoing transfemoral TAVR. Patients with small aortic valve annuli are typically female and are often underrepresented in clinical trials. METHODS: The SMART Trial is an international, prospective, multi-center, randomized controlled, post-market trial. The trial will be conducted in approximately 700 subjects at approximately 90 sites globally. Inclusion criteria include severe aortic stenosis, aortic valve annulus area of ≤430 mm2 based on multi-detector computed tomography, and appropriate anatomy for both the Medtronic Evolut PRO/PRO+ self-expanding and Edwards SAPIEN 3/3 Ultra balloon-expandable devices. The primary clinical outcome composite endpoint is defined as mortality, disabling stroke or heart failure rehospitalization at 12 months. The co-primary valve function composite endpoint is defined as bioprosthetic valve dysfunction at 12 months which includes hemodynamic structural valve dysfunction, defined as a mean gradient ≥20 mmHg, non-structural valve dysfunction, defined as severe prothesis-patient mismatch or ≥moderate aortic regurgitation, thrombosis, endocarditis, and aortic valve re-intervention. Powered secondary endpoints will be assessed hierarchically. CONCLUSIONS: The SMART trial will be the largest head-to-head comparative trial of transfemoral TAVR using the two most widely available contemporary TAVR devices in the setting of small aortic annuli and the largest trial to enroll primarily women. CLINICAL TRIAL REGISTRATION: URL: www.clinicaltrials.gov, Unique identifier: NCT04722250.
Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Feminino , Humanos , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter/métodos , Resultado do TratamentoRESUMO
BACKGROUND: Diabetes Mellitus (DM) affects a third of patients with symptomatic severe aortic valve stenosis undergoing transcatheter aortic valve implantation (TAVI). DM is a well-known risk factor for cardiac surgery, but its prognostic impact in TAVI patients remains controversial. This study aimed to evaluate outcomes in diabetic patients undergoing TAVI. METHODS: This multicentre registry includes data of > 12,000 patients undergoing transfemoral TAVI. We assessed baseline patient characteristics and clinical outcomes in patients with DM and without DM. Clinical outcomes were defined by the second valve academic research consortium. Propensity score matching was applied to minimize potential confounding. RESULTS: Of the 11,440 patients included, 31% (n = 3550) had DM and 69% (n = 7890) did not have DM. Diabetic patients were younger but had an overall worse cardiovascular risk profile than non-diabetic patients. All-cause mortality rates were comparable at 30 days (4.5% vs. 4.9%, RR 0.9, 95%CI 0.8-1.1, p = 0.43) and at one year (17.5% vs. 17.4%, RR 1.0, 95%CI 0.9-1.1, p = 0.86) in the unmatched population. Propensity score matching obtained 3281 patient-pairs. Also in the matched population, mortality rates were comparable at 30 days (4.7% vs. 4.3%, RR 1.1, 95%CI 0.9-1.4, p = 0.38) and one year (17.3% vs. 16.2%, RR 1.1, 95%CI 0.9-1.2, p = 0.37). Other clinical outcomes including stroke, major bleeding, myocardial infarction and permanent pacemaker implantation, were comparable between patients with DM and without DM. Insulin treated diabetics (n = 314) showed a trend to higher mortality compared with non-insulin treated diabetics (n = 701, Hazard Ratio 1.5, 95%CI 0.9-2.3, p = 0.08). EuroSCORE II was the most accurate risk score and underestimated 30-day mortality with an observed-expected ratio of 1.15 in DM patients, STS-PROM overestimated actual mortality with a ratio of 0.77 and Logistic EuroSCORE with 0.35. CONCLUSION: DM was not associated with mortality during the first year after TAVI. DM patients undergoing TAVI had low rates of mortality and other adverse clinical outcomes, comparable to non-DM TAVI patients. Our results underscore the safety of TAVI treatment in DM patients. TRIAL REGISTRATION: The study is registered at clinicaltrials.gov (NCT03588247).
Assuntos
Estenose da Valva Aórtica , Diabetes Mellitus , Substituição da Valva Aórtica Transcateter , Humanos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/epidemiologia , Diabetes Mellitus/etiologia , Pontuação de Propensão , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estudos Multicêntricos como Assunto , Sistema de RegistrosRESUMO
OBJECTIVES: The Evolut R FORWARD study confirmed safety and effectivenesss of the Evolut R THV in routine clinical practice out to 1 year. Herein, we report the final 3-year clinical follow up of the FORWARD study. BACKGROUND: Transcatheter aortic valve replacement (TAVR) is a proven alternative to surgery in elderly patients with symptomatic severe aortic stenosis. Long-term clinical outcome data with the Evolut R platform are scarce. METHODS: FORWARD is a prospective multicenter observational study that evaluated the Evolut R system in routine clinical practice at 53 centres. Eligible patients had symptomatic native aortic valve stenosis or failed surgical aortic bioprosthesis and elevated operative risk per Heart-Team assessment. TAVR was attempted in 1039 patients. RESULTS: Mean age was 81.8 ± 6.2 years, 64.9% were women, STS score was 5.5 ± 4.5% and 34.2% were frail. Rates of all-cause mortality and disabling stroke were 24.8% and 4.8% at 3 years. Early need for a new pacemaker implantation after TAVR (all-cause mortality: with new PPI; 21.0% vs. without; 22.8%, p = 0.55) and the presence of > trace paravalvular regurgitation (all-cause mortality: no or trace; 22.0% vs. ≥ mild; 25.5%, p = 0.29) did not affect survival. Between 1 and 3 years incidence rates of valve related intervention, endocarditis and clinically relevant valve thrombosis were low. CONCLUSIONS: The Evolut R valve maintained a favorable safety profile through 3 years in routine clinical practice. Rates of transcatheter heart valve-related adverse events were low.
Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Feminino , Humanos , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do TratamentoRESUMO
OBJECTIVES: Report contemporary outcomes in patients included in the Mitragister registry and treated with transcatheter mitral valve implantation for failed surgical annuloplasty rings or deteriorated bioprosthesis. BACKGROUND: Midterm survival rates have been reported, but little is known about contemporary morbimortality endpoints. METHODS: The primary safety outcome was the technical success rate. The primary efficacy composite endpoint was a composite of cardiovascular mortality and heart failure hospitalizations. RESULTS: From 2016 to 2021, 102 patients (median age: 81 [74;84] years, 61% female, Euroscore II 11.0% [7.8;16.0]) undergoing valve-in-valve (ViV; n = 89) or valve-in-ring (ViR; n = 13) procedures were consecutively included. At baseline, ViR group patients had worse left ventricular ejection fraction (50% vs. 60%; p = 0.004) and more frequently severe regurgitation (46% vs. 15%; p = 0.014). The primary safety outcome was 95%: 77% and 98% in the ViR and ViV populations, respectively, (p = 0.014). At intermediate follow-up (6-12 months) clinical improvement was notable, 88% of the patients were in NYHA class ≤ II (vs. 25% at baseline; p < 0.001). At a mean follow-up of 17.1 ± 11.0 months, the primary efficacy composite reached 27%. By multivariate analysis, paravalvular leak (PVL) was the only independent predictor (hazard ratio: 2.39, 95% confidence interval: 1.08-5.29; p = 0.031) while ViR was not found statistically associated (p = 0.456). CONCLUSIONS: This study confirms the safety and efficacy of the mitral ViV procedure. ViR patients appear at higher risk of procedural complications. The presence of PVL could be associated with markedly worse midterm prognosis. Whatever the intervention, procedural strategies to reduce PVL incidence remain to be assessed to prevent latter adverse outcomes.
Assuntos
Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral , Idoso de 80 Anos ou mais , Bioprótese/efeitos adversos , Cateterismo Cardíaco/métodos , Feminino , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Masculino , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Falha de Prótese , Sistema de Registros , Volume Sistólico , Resultado do Tratamento , Função Ventricular EsquerdaRESUMO
BACKGROUND: Midterm data comparing clinical outcomes after successful implantation of self-expanding and balloon-expandable transcatheter heart valves (THV) are limited. We aimed to compare 2-year outcomes after successful transcatheter aortic valve implantation (TAVI) with the Edwards balloon-expandable or the Medtronic self-expanding THV. METHODS: Two-year outcomes were analyzed according to the implanted THV in the GALILEO trial. Major adverse cardiac and cerebrovascular events (MACCE) was a composite of all-cause death or thromboembolic events including stroke, myocardial infarction, symptomatic valve thrombosis, systemic embolism, deep-vein thrombosis, or pulmonary embolism. RESULTS: Among 1644 patients recruited in 136 centers across 16 countries between 2015 and 2018, 499 received a self-expanding and 757 patients received a balloon-expandable THV. Patients treated with a self-expanding THV were more likely to be female, and had higher surgical risk, lower hemoglobin levels, and more frequent valve-in-valve procedures than those with a balloon-expandable THV. After multivariable adjustment, there were no significant differences in major clinical outcomes between self-expanding versus balloon-expandable THV: MACCE (17.0% vs. 13.4%, adjusted-hazard ratios [HR] 1.18, 95% confidence intervals [CI]: 0.82-1.69); all-cause death (11.4% vs. 9.3%, adjusted-HR 1.26; 95% CI: 0.78-2.05); cardiovascular death (8.5% vs. 4.0%, adjusted-HR 1.53; 95% CI: 0.82-2.86), any stroke (5.1% vs. 3.7%, adjusted-HR 0.86; 95% CI: 0.43-1.73); major or life-threatening bleeding (5.9% vs. 6.8%, adjusted-HR 0.93; 95% CI: 0.53-1.63). CLINICAL TRIAL REGISTRATION: https://www. CLINICALTRIALS: gov. NCT02556203. CONCLUSIONS: Two-year follow-up data from the GALILEO trial indicate that successful TAVI either with self-expanding or balloon-expandable THVs according to physician discretion did not show difference in rates of MACCE.
Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/etiologia , Estenose da Valva Aórtica/cirurgia , Feminino , Hemoglobinas , Humanos , Masculino , Desenho de Prótese , Acidente Vascular Cerebral/etiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do TratamentoRESUMO
BACKGROUND: Few randomized trials have compared bioprostheses for transcatheter aortic valve replacement, and no trials have compared bioprostheses with supra-annular design. The SCOPE 2 trial (Safety and Efficacy Comparison of Two TAVI Systems in a Prospective Randomized Evaluation 2) was designed to compare the clinical outcomes of the ACURATE neo and CoreValve Evolut bioprostheses for transcatheter aortic valve replacement. METHODS: SCOPE 2 was a randomized trial performed at 23 centers in 6 countries between April 2017 and April 2019. Patients ≥75 years old with an indication for transfemoral transcatheter aortic valve replacement as agreed by the heart team were randomly assigned to receive treatment with either the ACURATE neo (n=398) or the CoreValve Evolut bioprostheses (n=398). The primary end point, powered for noninferiority of the ACURATE neo bioprosthesis, was all-cause death or stroke at 1 year. The key secondary end point, powered for superiority of the ACURATE neo bioprosthesis, was new permanent pacemaker implantation at 30 days. RESULTS: Among 796 randomized patients (mean age, 83.2±4.3 years; mean Society of Thoracic Surgeons Predicted Risk of Mortality score, 4.6±2.9%), clinical follow-up information was available for 778 (98%) patients. Within 1 year, the primary end point occurred in 15.8% of patients in the ACURATE neo group and in 13.9% of patients in the CoreValve Evolut group (absolute risk difference, 1.8%, upper 1-sided 95% confidence limit, 6.1%; P=0.0549 for noninferiority). The 30-day rates of new permanent pacemaker implantation were 10.5% in the ACURATE neo group and 18.0% in the CoreValve Evolut group (absolute risk difference, -7.5% [95% CI, -12.4 to -2.60]; P=0.0027). No significant differences were observed in the components of the primary end point. Cardiac death at 30 days (2.8% versus 0.8%; P=0.03) and 1 year (8.4% versus 3.9%; P=0.01), and moderate or severe aortic regurgitation at 30 days (10% versus 3%; P=0.002) were significantly increased in the ACURATE neo group. CONCLUSIONS: Transfemoral transcatheter aortic valve replacement with the self-expanding ACURATE neo did not meet noninferiority compared with the self-expanding CoreValve Evolut in terms of all-cause death or stroke at 1 year, and it was associated with a lower incidence of new permanent pacemaker implantation. In secondary analyses, the ACURATE neo was associated with more moderate or severe aortic regurgitation at 30 days and cardiac death at 30 days and 1 year. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03192813.
Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Europa (Continente) , Feminino , Hemodinâmica , Humanos , Masculino , Desenho de Prótese , Recuperação de Função Fisiológica , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Acidente Vascular Cerebral/etiologia , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do TratamentoRESUMO
BACKGROUND: Procedural improvements combined with the contemporary clinical profile of patients undergoing transcatheter aortic valve replacement (TAVR) may have influenced the incidence and outcomes of infective endocarditis (IE) following TAVR. We aimed to determine the temporal trends, characteristics, and outcomes of IE post-TAVR. METHODS: Observational study including 552 patients presenting definite IE post-TAVR. Patients were divided in 2 groups according to the timing of TAVR (historical cohort [HC]: before 2014; contemporary cohort [CC]: after 2014). RESULTS: Overall incidence rates of IE were similar in both cohorts (CC vs HC: 5.45 vs 6.52 per 1000 person-years; Pâ =â .12), but the rate of early IE was lower in the CC (2.29 vs 4.89, Pâ <â .001). Enterococci were the most frequent microorganism. Most patients presented complicated IE ( CC: 67.7%; HC: 69.6%; Pâ =â .66), but the rate of surgical treatment remained low (CC: 20.7%; HC: 17.3%; Pâ =â .32). The CC exhibited lower rates of in-hospital acute kidney injury (35.1% vs 44.6%; Pâ =â .036) and in-hospital (26.6% vs 36.4%; Pâ =â .016) and 1-year (37.8% vs 53.5%; Pâ <â .001) mortality. Higher logistic EuroScore, Staphylococcus aureus etiology, and complications (stroke, heart failure, and acute renal failure) were associated with in-hospital mortality in multivariable analyses (Pâ <â .05 for all). CONCLUSIONS: Although overall IE incidence has remained stable, the incidence of early IE has declined in recent years. The microorganism, high rate of complications, and very low rate of surgical treatment remained similar. In-hospital and 1-year mortality rates were high but progressively decreased over time.
Assuntos
Endocardite Bacteriana , Endocardite , Substituição da Valva Aórtica Transcateter , Endocardite/epidemiologia , Endocardite/etiologia , Endocardite/cirurgia , Endocardite Bacteriana/epidemiologia , Endocardite Bacteriana/etiologia , Endocardite Bacteriana/cirurgia , Humanos , Incidência , Complicações Pós-Operatórias/epidemiologia , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do TratamentoRESUMO
OBJECTIVES: To evaluate the effectiveness of anticoagulant therapies in patients with clinical transcatheter heart valve (THV) thrombosis, to describe complications, and to assess their risk profile was the objectives. BACKGROUND: Little research has been conducted on clinical THV thrombosis. METHODS: Patients with clinical THV thrombosis were identified based on greater than 50% increased transvalvular gradient on transthoracic echocardiogram confirmed by 4-dimensional computed tomography, transesophageal echocardiogram, or regression with anticoagulant therapy. A cohort free from thrombosis for more than 1,100 days postprocedure was used for comparison. RESULTS: Fifty-four patients with clinical THV thrombosis were identified. Most subjects (98.1%) received anticoagulant therapy which was effective (≥50% reduction in transvalvular gradient or return to postprocedure value) in 96%. The rate of serious hemodynamic or embolic complications in the thrombosis population was 31.5%. A multivariate analysis of subjects with and without thrombosis indicated a significantly increased risk of thrombosis from preexisting thrombocytopenia (odds ratio [OR] 9.96), absence of predilatation (OR = 5.67), renal insufficiency (OR = 4.84), and >10 mmHg mean transvalvular gradient postprocedure (OR = 3.36). No recurrence of thrombosis was identified during on average 685 days follow-up. CONCLUSIONS: These data, from one of the largest cohorts with clinical THV thrombosis confirm anticoagulants appear effective. The rate of serious associated complications was high. The findings underline the importance of recognizing risk factors for thrombosis.
Assuntos
Estenose da Valva Aórtica , Trombose Coronária , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Estudos de Coortes , Humanos , Desenho de Prótese , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do TratamentoRESUMO
OBJECTIVES: To evaluate outcome and its predictors of bioprosthetic valve fracture (BVF) in patients undergoing valve-in-valve transcatheter aortic valve replacement (VIV-TAVR). BACKGROUND: BVF is feasible and reduces transvalvular gradients in VIV-TAVR-procedures, but follow-up-data and information on factors influencing the outcome are missing. METHODS: The 81 cases of BVF-VIV-TAVR were collected from 14 international centers. RESULTS: Predominantly transcatheter heart valve (THV) was implanted first, followed by BVF. VARC-2 defined device success was 93%, most failures were attributed to residual high gradients. Mean gradients decreased from 37 ± 13 mmHg to 10.8 ± 5.9 mmHg (p < 0.001). BVF reduced the gradient by 16 mmHg. During follow-up (FU, 281 ± 164 days) mean gradient remained stable (10.8 ± 5.9 mmHg at discharge, 12.4 ± 6.3 mmHg at FU, p = ns). In-hospital major adverse events occurred in 3.7%. Event-free survival at 276 ± 237.6 days was 95.4%. The linear mixed model identified balloon-expandable valves (BEV), Mitroflow surgical valve, stenotic surgical bioprostheses and balloon only 1 mm larger than the true internal diameter of the surgical valve as predictors for higher gradients. CONCLUSIONS: BVF is safe and can significantly reduce gradients, which remain stable at FU. BEV, Mitroflow surgical valve, stenotic bioprostheses and balloon larger than the true internal diameter of the surgical valve of only 1 mm are predictors for higher final gradients.
Assuntos
Estenose da Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Seguimentos , Hemodinâmica , Humanos , Desenho de Prótese , Falha de Prótese , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do TratamentoRESUMO
OBJECTIVES: To describe the incidence, predictors, and clinical impact of permanent pacemaker insertion (PPI) following transcatheter aortic valve replacement (TAVR) in women. BACKGROUND: Data on pacemaker insertion complicating TAVR in women are scarce. METHODS: The Women's International Transcatheter Aortic Valve implantation (WIN-TAVI) is a prospective registry evaluating the safety and efficacy of TAVR in women. We included patients without preprocedural pacemakers and divided them into two groups: (1) PPI and (2) no-PPI. We identified PPI predictors using logistic regression and studied its clinical impact on the Valve Academic Research Consortium (VARC)-2 efficacy and safety endpoints. RESULTS: Out of 1019 patients, 922 were included in the analysis. Post-TAVR PPI occurred in 132 (14.3%) patients. Clinical and procedural characteristics were similar in both groups. Pre-existing right bundle branch block (RBBB) was associated with a high risk of post-TAVR PPI (OR 3.62, 95% CI 1.85-7.06, p < 0.001), while implantation of balloon-expandable prosthesis was associated with a lower risk (OR 0.47, 95% CI 0.30-0.74, p < 0.001). Post-TAVR PPI prolonged in-hospital stay by a median of 2 days (11 [9-16] days in PPI vs. 9 [7-14] days in no-PPI, p = 0.005), yet risks of VARC-2 efficacy and safety endpoints at 1 year were similar in both groups (adj HR 0.95, 95% CI 0.60-1.52, p = 0.84 and adj HR 1.22, 95% CI 0.83-1.79, p = 0.31, respectively). CONCLUSION: Pacemaker implantation following TAVR is frequent among women and is associated with pre-existing RBBB and valve type. PPI prolongs hospital stay, albeit without any significant impact on 1-year outcomes.