Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Eur J Clin Microbiol Infect Dis ; 42(11): 1327-1335, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37749274

RESUMO

Toxoplasmosis is a ubiquitous parasitic infection caused by Toxoplasma gondii (Tg). In immunocompetent people, the infection may be asymptomatic with the induction of an immune response that may prevent reinfection or transmission to the fetus in immune pregnant woman. In immunocompromised persons or seronegative pregnant woman with a primary infection during pregnancy, the infection may result in the loss of life, sight, cognition, and motor function in the immune-compromised person or immunologically immature fetus. The objective of this study was to evaluate a new immunochromatographic test Toxoplasma ICT IgG-IgM (ICT) that allows detection of specific anti-Tg immunoglobulins G (Ig G) and M (Ig M). We included 1145 prospectively obtained sera and 376 samples selected for specificity or sensitivity studies. The performance of ICT was compared using Vidas® Toxo Competition (TXC) and Toxoscreen®. In case of discrepancy, Vidas® Toxo Ig G or Ig M and LDBIO Toxo II IgG western blot were used to establish definitive results by additional methods. Sensitivity and specificity of ICT were respectively 99.3% and 100%. In comparison, Toxoscreen®'s sensitivity was 100% and the specificity was 99.8%. TXC had a sensitivity of 98.7% with a specificity of 99.1%. ICT has excellent performance even for low Ig G titers, especially in immunocompromised patients, and confirms the specificity of isolated Ig M. This ICT provides reliable results easily and quickly. This screening technique is not designed to differentiate the Ig M from Ig G. When positive, additional tests may be necessary.

3.
Clin Infect Dis ; 67(3): 327-333, 2018 07 18.
Artigo em Inglês | MEDLINE | ID: mdl-29471464

RESUMO

Background: Influenza vaccination aims to prevent infection by influenza virus and reduce associated morbidity and mortality; however, vaccine effectiveness (VE) can be modest, especially for subtype A(H3N2). Low VE has been attributed to mismatches between the vaccine and circulating influenza strains and to the vaccine's elicitation of protective immunity in only a subset of the population. The low H3N2 VE in the 2012-2013 season was attributed to egg-adaptive mutations that created antigenic mismatch between the actual vaccine strain (IVR-165) and both the intended vaccine strain (A/Victoria/361/2011) and the predominant circulating strains (clades 3C.2 and 3C.3). Methods: We investigated the basis of low VE in 2012-2013 by determining whether vaccinated and unvaccinated individuals were infected by different viral strains and by assessing the serologic responses to IVR-165, A/Victoria/361/2011, and 3C.2 and 3C.3 strains in an adult cohort before and after vaccination. Results: We found no significant genetic differences between the strains that infected vaccinated and unvaccinated individuals. Vaccination increased titers to A/Victoria/361/2011 and 3C.2 and 3C.3 representative strains as much as to IVR-165. These results are consistent with the hypothesis that vaccination boosted cross-reactive immune responses instead of specific responses against unique vaccine epitopes. Only approximately one-third of the cohort achieved a ≥4-fold increase in titer. Conclusions: In contrast to analyses based on ferret studies, low H3N2 VE in 2012-2013 in adults does not appear to be due to egg adaptation of the vaccine strain. Instead, low VE might have been caused by low vaccine immunogenicity in a subset of the population.


Assuntos
Imunogenicidade da Vacina , Vírus da Influenza A Subtipo H3N2/genética , Vacinas contra Influenza/imunologia , Influenza Humana/epidemiologia , Adaptação Fisiológica , Adulto , Idoso , Idoso de 80 Anos ou mais , Animais , Antígenos Virais/imunologia , Estudos de Coortes , Reações Cruzadas , Ovos/virologia , Furões , Genoma Viral , Sequenciamento de Nucleotídeos em Larga Escala , Humanos , Vírus da Influenza A Subtipo H3N2/isolamento & purificação , Vacinas contra Influenza/uso terapêutico , Influenza Humana/prevenção & controle , Mutação , Filogenia , Estações do Ano
4.
J Clin Microbiol ; 56(1)2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-29118168

RESUMO

The Accelerate Pheno system uses automated fluorescence in situ hybridization technology with morphokinetic cellular analysis to provide rapid species identification (ID) and antimicrobial susceptibility testing (AST) results for the most commonly identified organisms in bloodstream infections. The objective was to evaluate the accuracy and workflow of bacterial and yeast ID and bacterial AST using the Accelerate Pheno system in the clinical microbiology laboratory. The consecutive fresh blood cultures received in the laboratory were analyzed by the Accelerate Pheno system within 0 to 8 h of growth detection. ID/AST performance, the average times to results, and workflow were compared to those of the routine standard of care. Of the 232 blood cultures evaluated (223 monomicrobial and 9 polymicrobial) comprising 241 organisms, the overall sensitivity and specificity for the identification of organisms were 95.6% and 99.5%, respectively. For antimicrobial susceptibility, the overall essential agreement was 95.1% and categorical agreement was 95.5% compared to routine methods. There was one very major error and 3 major errors. The time to identification and the time to susceptibility using the Accelerate Pheno system were decreased by 23.47 and 41.86 h, respectively, compared to those for the standard of care. The reduction in hands on time was 25.5 min per culture. The Accelerate Pheno system provides rapid and accurate ID/AST results for most of the organisms found routinely in blood cultures. It is easy to use, reduces hands on time for ID/AST of common blood pathogens, and enables clinically actionable results to be released much earlier than with the current standard of care.


Assuntos
Bactérias/isolamento & purificação , Sangue/microbiologia , Fungos/isolamento & purificação , Testes de Sensibilidade Microbiana/métodos , Técnicas Microbiológicas/métodos , Sepse/diagnóstico , Fluxo de Trabalho , Anti-Infecciosos/farmacologia , Automação Laboratorial , Bactérias/efeitos dos fármacos , Bactérias/genética , Fungos/efeitos dos fármacos , Fungos/genética , Hospitais Universitários , Humanos , Hibridização in Situ Fluorescente , Sensibilidade e Especificidade , Sepse/microbiologia , Fatores de Tempo
5.
J Clin Microbiol ; 54(7): 1902-1903, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-27098956

RESUMO

The Xpert Flu/RSV XC was compared to the FilmArray respiratory panel for detection of influenza (Flu) A, Flu B, and respiratory syncytial virus (RSV), using 128 nasopharyngeal swabs. Positive agreements were 100% for Flu A and RSV and 92.3% for Flu B. The Xpert may be useful in clinical situations when extensive testing is not required and may serve an important role in laboratories already performing broader respiratory panel testing.


Assuntos
Vírus da Influenza A/isolamento & purificação , Vírus da Influenza B/isolamento & purificação , Influenza Humana/diagnóstico , Técnicas de Diagnóstico Molecular/métodos , Infecções por Vírus Respiratório Sincicial/diagnóstico , Vírus Sinciciais Respiratórios/isolamento & purificação , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Masculino , Pessoa de Meia-Idade , Nasofaringe/virologia , Adulto Jovem
6.
Am J Physiol Lung Cell Mol Physiol ; 309(1): L76-83, 2015 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-25957290

RESUMO

Acute lung injury (ALI) and the more severe acute respiratory distress syndrome are common responses to a variety of infectious and noninfectious insults. We used a mouse model of ALI induced by intratracheal administration of sterile bacterial wall lipopolysaccharide (LPS) to investigate the changes in innate lung microbiota and study microbial community reaction to lung inflammation and barrier dysfunction induced by endotoxin insult. One group of C57BL/6J mice received LPS via intratracheal injection (n = 6), and another received sterile water (n = 7). Bronchoalveolar lavage (BAL) was performed at 72 h after treatment. Bacterial DNA was extracted and used for qPCR and 16S rRNA gene-tag (V3-V4) sequencing (Illumina). The bacterial load in BAL from ALI mice was increased fivefold (P = 0.03). The community complexity remained unchanged (Simpson index, P = 0.7); the Shannon diversity index indicated the increase of community evenness in response to ALI (P = 0.07). Principal coordinate analysis and analysis of similarity (ANOSIM) test (P = 0.005) revealed a significant difference between microbiota of control and ALI groups. Bacteria from families Xanthomonadaceae and Brucellaceae increased their abundance in the ALI group as determined by Metastats test (P < 0.02). In concordance with the 16s-tag data, Stenotrohomonas maltophilia (Xanthomonadaceae) and Ochrobactrum anthropi (Brucellaceae) were isolated from lungs of mice from both groups. Metabolic profiling of BAL detected the presence of bacterial substrates suitable for both isolates. Additionally, microbiota from LPS-treated mice intensified IL-6-induced lung inflammation in naive mice. We conclude that the morbid transformation of ALI microbiota was attributed to the set of inborn opportunistic pathogens thriving in the environment of inflamed lung, rather than the external infectious agents.


Assuntos
Lesão Pulmonar/microbiologia , Pulmão/microbiologia , Microbiota/efeitos dos fármacos , Síndrome do Desconforto Respiratório/microbiologia , Animais , Sequência de Bases , Líquido da Lavagem Broncoalveolar/microbiologia , Brucellaceae/genética , Brucellaceae/isolamento & purificação , DNA Bacteriano/genética , Modelos Animais de Doenças , Lipopolissacarídeos/toxicidade , Camundongos , Camundongos Endogâmicos C57BL , RNA Ribossômico 16S/genética , Análise de Sequência de DNA , Xanthomonadaceae/genética , Xanthomonadaceae/isolamento & purificação
9.
Lab Med ; 2024 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-38780098

RESUMO

We report a fatal case of Legionella feeleii endocarditis in a post-lung transplant patient. The diagnosis was delayed, as routine microbiological testing of nonrespiratory specimens does not account for extrapulmonary Legionella, and urine antigen testing only reliably detects Legionella pneumophila serogroup 1. This case also illustrates the utility of molecular sequencing for blood culture-negative endocarditis.

10.
PLoS Negl Trop Dis ; 18(5): e0011335, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38805559

RESUMO

BACKGROUND: Congenital toxoplasmosis is a treatable, preventable disease, but untreated causes death, prematurity, loss of sight, cognition and motor function, and substantial costs worldwide. OBJECTIVES: We asked whether high performance of an Immunochromatographic-test (ICT) could enable accurate, rapid diagnosis/treatment, establishing new, improved care-paradigms at point-of-care and clinical laboratory. METHODS: Data were obtained in 12 studies/analyses addressing: 1-feasibility/efficacy; 2-false-positives; 3-acceptability; 4-pink/black-line/all studies; 5-time/cost; 6-Quick-Information/Limit-of-detection; 7, 8-acute;-chronic; 9-epidemiology; 10-ADBio; 11,12-Commentary/Cases/Chronology. FINDINGS: ICT was compared with gold-standard or predicate-tests. Overall, ICT performance for 1093 blood/4967 sera was 99.2%/97.5% sensitive and 99.0%/99.7% specific. However, in clinical trial, FDA-cleared-predicate tests initially caused practical, costly problems due to false-positive-IgM results. For 58 persons, 3/43 seronegative and 2/15 chronically infected persons had false positive IgM predicate tests. This caused substantial anxiety, concerns, and required costly, delayed confirmation in reference centers. Absence of false positive ICT results contributes to solutions: Lyon and Paris France and USA Reference laboratories frequently receive sera with erroneously positive local laboratory IgM results impeding patient care. Therefore, thirty-two such sera referred to Lyon's Reference laboratory were ICT-tested. We collated these with other earlier/ongoing results: 132 of 137 USA or French persons had false-positive local laboratory IgM results identified correctly as negative by ICT. Five false positive ICT results in Tunisia and Marseille, France, emphasize need to confirm positive ICT results with Sabin-Feldman-Dye-test or western blot. Separate studies demonstrated high performance in detecting acute infections, meeting FDA, CLIA, WHO REASSURED, CEMark criteria and patient and physician satisfaction with monthly-gestational-ICT-screening. CONCLUSIONS/SIGNIFICANCE: This novel paradigm using ICT identifies likely false positives or raises suspicion that a result is truly positive, rapidly needing prompt follow up and treatment. Thus, ICT enables well-accepted gestational screening programs that facilitate rapid treatment saving lives, sight, cognition and motor function. This reduces anxiety, delays, work, and cost at point-of-care and clinical laboratories. TRIAL REGISTRATION: NCT04474132, https://clinicaltrials.gov/study/NCT04474132 ClinicalTrials.gov.


Assuntos
Toxoplasmose Congênita , Feminino , Humanos , Recém-Nascido , Gravidez , Anticorpos Antiprotozoários/sangue , Reações Falso-Positivas , Imunoglobulina M/sangue , Diagnóstico Pré-Natal/métodos , Sensibilidade e Especificidade , Toxoplasma/imunologia , Toxoplasmose Congênita/diagnóstico , Toxoplasmose Congênita/prevenção & controle
11.
Int J STD AIDS ; 33(8): 761-765, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35610756

RESUMO

BACKGROUND: Screening for Neisseria gonorrhoeae and Chlamydia trachomatis is recommended for individuals at high-risk for sexually transmitted infections (STIs), while the role of Mycoplasma genitalium screening is still unclear. We evaluated whether specimen pooling is an effective alternative for sexually transmitted infection testing during resource shortages. METHODS: This 2-year prospective study enrolled 135 asymptomatic patients from a community outreach site who identified as men who have sex with men. Oropharyngeal, urine, and/or rectal swab specimens were pooled and tested using the Aptima Combo 2 assay for Neisseria gonorrhoeae and Chlamydia trachomatis. The Aptima Mycoplasma genitalium assay was performed on 34 patients whose specimens had sufficient sample volume for additional testing. Results from pooled specimens were compared to results obtained by individual-site testing. RESULTS: The positive percent agreement (PPA) between pooled testing and individual-site testing was 93.8% and negative percent agreement (NPA) was 100% for Neisseria gonorrhoeae. For Chlamydia trachomatis, the PPA was 85.7% and NPA was 99.2%. A PPA of 72.7% and NPA of 95.7% were observed for Mycoplasma genitalium. Discrepancy analysis revealed the majority of false-negative pools were from failure to detect positive rectal samples. CONCLUSIONS: Specimen pooling reduces sensitivity of the Aptima assays for Chlamydia trachomatis, Neisseria gonorrhoeae, and Mycoplasma genitalium and thus should be used with caution.


Assuntos
Infecções por Chlamydia , Gonorreia , Infecções por Mycoplasma , Mycoplasma genitalium , Minorias Sexuais e de Gênero , Infecções Sexualmente Transmissíveis , Infecções por Chlamydia/diagnóstico , Infecções por Chlamydia/epidemiologia , Chlamydia trachomatis/genética , Gonorreia/diagnóstico , Gonorreia/epidemiologia , Homossexualidade Masculina , Humanos , Masculino , Infecções por Mycoplasma/diagnóstico , Infecções por Mycoplasma/epidemiologia , Neisseria gonorrhoeae/genética , Estudos Prospectivos , Infecções Sexualmente Transmissíveis/diagnóstico , Infecções Sexualmente Transmissíveis/epidemiologia
12.
Am J Clin Pathol ; 157(1): 109-118, 2022 01 06.
Artigo em Inglês | MEDLINE | ID: mdl-34463315

RESUMO

OBJECTIVES: To analytically and clinically evaluate the semiquantitative Elecsys anti-severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) spike protein antibody (S-Ab) assay on the Roche cobas e602 analyzer. METHODS: The S-Ab assay is a 1-step, double-antigen sandwich electrochemiluminescent immunoassay that semiquantitatively measures total IgG, IgM, and IgA antibodies specific for the receptor binding domain of SARS-CoV-2 spike protein in serum or plasma. The S-Ab assay was evaluated for precision, linearity, interference (by hemoglobin, bilirubin, triglycerides, and biotin), cross-reactivity, and clinical performance, and was compared to the qualitative Elecsys anti-nucleocapsid (N-Ab) immunoassay, a lateral flow device that qualitatively detects S-Ab and N-Ab, and an anti-spike enzyme-linked immunosorbent assay (ELISA). RESULTS: S-Ab assay is precise, exhibits linearity from 0.4 to 250 U/mL, is unaffected by significant cross-reactivity or interferences, and qualitatively demonstrates greater than 90% concordance with N-Ab assay and lateral flow device. Readouts of S-Ab assay correlate with ELISA, which in turn correlates strongly with SARS-CoV-2 virus neutralization assay, and exhibit 100% sensitivity and specificity for COVID-19 patient samples obtained at or more than 14 days after PCR positivity. CONCLUSIONS: The S-Ab assay is a robust clinical test for qualitative and semiquantitative detection of seropositivity following SARS-CoV-2 infection or spike-encoding mRNA COVID-19 vaccination.


Assuntos
COVID-19 , Glicoproteína da Espícula de Coronavírus , Anticorpos Antivirais , Vacinas contra COVID-19 , Humanos , SARS-CoV-2 , Sensibilidade e Especificidade
13.
J Clin Microbiol ; 49(4): 1518-23, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21270229

RESUMO

"Pseudomonas andersonii" is a Gram-negative bacillus initially isolated from a granulomatous lung lesion. Novel species status has not been validated for this single strain. We report four additional cases of pulmonary granuloma involving P. andersonii and further characterize the organism. These patients had pulmonary nodules that were surgically resected and which grew P. andersonii on routine culture. Mycobacterium avium complex was concomitantly isolated in two cases, and fungal structures were identified histopathologically in two other cases. The five P. andersonii strains described to date were similar in growth characteristics, biochemical reactions, matrix-assisted laser desorption ionization-time of flight mass spectrometry protein profiles, and susceptibility to antimicrobial agents. Their 16S rRNA genes were 99.9 to 100% identical but less than 95.0% similar to those of all other known bacteria. The gyrA genes of these strains were 99.5 to 100% identical. These shared features illustrate P. andersonii as a unique and distinct bacterium and support the novel species status of the organism.


Assuntos
Granuloma do Sistema Respiratório/microbiologia , Infecções por Pseudomonas/microbiologia , Pseudomonas/isolamento & purificação , Idoso , Proteínas de Bactérias/análise , Técnicas de Tipagem Bacteriana , DNA Bacteriano/química , DNA Bacteriano/genética , DNA Ribossômico/química , DNA Ribossômico/genética , Feminino , Granuloma do Sistema Respiratório/patologia , Humanos , Pulmão/microbiologia , Pulmão/patologia , Masculino , Testes de Sensibilidade Microbiana , Pessoa de Meia-Idade , Dados de Sequência Molecular , Complexo Mycobacterium avium/isolamento & purificação , Pseudomonas/química , Pseudomonas/genética , Pseudomonas/metabolismo , Infecções por Pseudomonas/patologia , RNA Ribossômico 16S/genética , Análise de Sequência de DNA , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz
14.
Lab Med ; 52(3): e50-e52, 2021 May 04.
Artigo em Inglês | MEDLINE | ID: mdl-32954440

RESUMO

Cording is a phenomenon in which acid fast bacilli grow in parallel and was previously used as a means of presumptive microscopic identification of Mycobacterium tuberculosis (TB). However, this process has been shown in multiple other nontuberculous mycobacterial (NTM) species. Here we present the case of an immunocompromised adult who presented with wrist pain, weight loss, and cough. A positron emission tomography scan showed uptake in the right ulna, multiple soft tissue sites, and the left lung. Biopsies and cultures were obtained from multiple sites, and the patient was ultimately diagnosed with disseminated Mycobacterium chelonae infection. The organism showed cording in culture. As seen in this patient, cording may occur in multiple NTM species and is not reliable as the sole indicator of the presence of TB.


Assuntos
Infecções por Mycobacterium não Tuberculosas , Mycobacterium chelonae , Mycobacterium tuberculosis , Adulto , Biópsia , Humanos , Hospedeiro Imunocomprometido , Infecções por Mycobacterium não Tuberculosas/diagnóstico
15.
Am J Clin Pathol ; 155(2): 286-295, 2021 02 04.
Artigo em Inglês | MEDLINE | ID: mdl-33135049

RESUMO

OBJECTIVES: To evaluate the analytical and clinical performance of the Truvian Easy Check coronavirus disease 2019 (COVID-19) IgM/IgG anti-severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) antibody test.Serologic assays have become increasingly available for surveillance through the Food and Drug Administration emergency use authorization in the ongoing COVID-19 global pandemic. However, widespread application of serologic assays has been curbed by reports of faulty or inaccurate tests. Therefore, rapid COVID-19 antibody tests need to be thoroughly validated prior to their implementation. METHODS: The Easy Check device was analytically evaluated and its performance was compared with the Roche Elecsys anti-SARS-CoV-2 antibody assay. The test was further characterized for cross-reactivity using sera obtained from patients infected by other viruses. Clinical performance was analyzed with polymerase chain reaction-confirmed samples and a 2015 prepandemic reference sample set. RESULTS: The Easy Check device showed excellent analytical performance and compares well with the Roche Elecsys antibody assay, with an overall concordance of 98.6%. Clinical performance showed a sensitivity of 96.6%, a specificity of 98.2%, and an overall accuracy of 98.1%. CONCLUSIONS: The Easy Check device is a simple, reliable, and rapid test for detection of SARS-CoV-2 seropositivity, and its performance compares favorably against the automated Roche Elecsys antibody assay.


Assuntos
Anticorpos Antivirais/sangue , Teste Sorológico para COVID-19/instrumentação , COVID-19/diagnóstico , SARS-CoV-2/imunologia , Reações Cruzadas , Humanos , Imunoglobulina G/sangue , Imunoglobulina M/sangue , Sensibilidade e Especificidade
16.
Am J Surg Pathol ; 45(5): 672-679, 2021 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-33534221

RESUMO

Historic and current pathology society guidelines recommend using visual gestalt to identify substantial inflammatory cell infiltrate in Helicobacter pylori gastritis, but these scales were subjectively designed. This study aims to objectively investigate the density of inflammation that justifies additional workup for H. pylori infection. We retrospectively identified 2 patient cohorts who had undergone endoscopy with gastric biopsies; 1 with H. pylori infection (n=66), confirmed with a positive stool antigen test and/or Campylobacter-like organism test, and 1 without infection (n=81). Antral and body biopsies were selected from each case, if available, and stained with MUM-1 to highlight mucosal plasma cells. Digital analysis was performed to calculate the number of plasma cells/mm2, termed the "inflammatory score" (IS). Patients with H. pylori infection had an average of 1289 plasma cells/mm2 in the antrum and 835 plasma cells/mm2 in the body, compared with 346 plasma cells/mm2 in the antrum and 178 plasma cells/mm2 in the body in patients without infection. IS cut-off values for a positive infection were 714 plasma cells/mm2 in the antrum and 316 plasma cells/mm2 in the body, with high sensitivities and specificities in both the antrum (92%, 92%) and body (85%, 84%), respectively. A visual analog scale was created to provide a histologic correlate of the observed IS ranges and cut-offs. This practical and objective scale is associated with a high sensitivity and specificity for diagnosing H. pylori infection and justifies moving away from upfront universal H. pylori testing in routine clinical practice.


Assuntos
Gastrite/patologia , Infecções por Helicobacter/patologia , Helicobacter pylori/isolamento & purificação , Plasmócitos/patologia , Estômago/patologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Biomarcadores/análise , Biópsia , Criança , Pré-Escolar , Feminino , Gastrite/metabolismo , Gastrite/microbiologia , Gastroscopia , Infecções por Helicobacter/metabolismo , Infecções por Helicobacter/microbiologia , Humanos , Imuno-Histoquímica , Fatores Reguladores de Interferon/análise , Masculino , Pessoa de Meia-Idade , Plasmócitos/química , Plasmócitos/microbiologia , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Estômago/química , Estômago/microbiologia , Adulto Jovem
17.
Infect Control Hosp Epidemiol ; 42(3): 351-352, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-32959739

RESUMO

We implemented universal inpatient Clostridioides difficile screening at an 800-bed hospital. Over 3 years, 2,010 of 47,048 screening tests (4.2%) were positive, with significantly higher rates of C. difficile colonization on transplant units than medical-surgical units: 5.4% (152 of 2,801) versus 4.3% (880 of 20,564), respectively (P = .005). Compliance with screening ranged from 79% to 96%.


Assuntos
Clostridioides difficile , Infecções por Clostridium , Centros Médicos Acadêmicos , Clostridioides , Infecções por Clostridium/diagnóstico , Infecções por Clostridium/epidemiologia , Humanos , Pacientes Internados
18.
mBio ; 12(1)2021 01 19.
Artigo em Inglês | MEDLINE | ID: mdl-33468695

RESUMO

Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is currently causing a global pandemic. The antigen specificity of the antibody response mounted against this novel virus is not understood in detail. Here, we report that subjects with a more severe SARS-CoV-2 infection exhibit a larger antibody response against the spike and nucleocapsid protein and epitope spreading to subdominant viral antigens, such as open reading frame 8 and nonstructural proteins. Subjects with a greater antibody response mounted a larger memory B cell response against the spike, but not the nucleocapsid protein. Additionally, we revealed that antibodies against the spike are still capable of binding the D614G spike mutant and cross-react with the SARS-CoV-1 receptor binding domain. Together, this study reveals that subjects with a more severe SARS-CoV-2 infection exhibit a greater overall antibody response to the spike and nucleocapsid protein and a larger memory B cell response against the spike.IMPORTANCE With the ongoing pandemic, it is critical to understand how natural immunity against SARS-CoV-2 and COVID-19 develops. We have identified that subjects with more severe COVID-19 disease mount a more robust and neutralizing antibody response against SARS-CoV-2 spike protein. Subjects who mounted a larger response against the spike also mounted antibody responses against other viral antigens, including the nucleocapsid protein and ORF8. Additionally, this study reveals that subjects with more severe disease mount a larger memory B cell response against the spike. These data suggest that subjects with more severe COVID-19 disease are likely better protected from reinfection with SARS-CoV-2.


Assuntos
COVID-19/imunologia , SARS-CoV-2/imunologia , Glicoproteína da Espícula de Coronavírus/imunologia , Adulto , Anticorpos Neutralizantes/imunologia , Anticorpos Antivirais/sangue , Anticorpos Antivirais/imunologia , Antígenos Virais/imunologia , Linfócitos B/imunologia , COVID-19/sangue , COVID-19/virologia , Proteínas do Nucleocapsídeo de Coronavírus/imunologia , Reações Cruzadas , Epitopos/imunologia , Feminino , Humanos , Imunidade Humoral/imunologia , Masculino , Pessoa de Meia-Idade , Fosfoproteínas/imunologia
20.
Clin Chim Acta ; 510: 671-674, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32818493

RESUMO

BACKGROUND: Venous blood samples collected in evacuated blood collection tubes are generally not considered suitable for measurement of oxygenation status. However, whether pH, pCO2 and HCO3- results from venous blood samples collected in evacuated tubes are reliable remains unclear. METHODS: Paired samples were collected from 38 healthy volunteers using two collection methods: (1) collection of blood directly into a blood gas syringe and (2) collection of blood into an evacuated tube with subsequent anaerobic transfer into a blood gas syringe. Samples were analyzed for pH, pCO2, HCO3-, and pO2. RESULTS: Samples collected in evacuated tubes showed significant positive mean biases of 0.03 and 7.5 mmHg for pH and pO2, respectively, and significant negative mean biases of 5.0 mmHg and 1.2 mmol/l for pCO2 and HCO3-, respectively. Collection in evacuated tubes resulted in biases exceeding the total allowable errors in 16%, 40%, 21% of samples for pH, pCO2, HCO3-, respectively, when compared to samples collected in syringes directly. CONCLUSIONS: Samples for venous blood gas analysis should be collected directly into blood gas syringes for accurate assessment of ventilation and/or acid-base status. Biases observed for samples collected in evacuated tubes are consistent with air contamination and/or vacuum effects.


Assuntos
Coleta de Amostras Sanguíneas , Seringas , Gasometria , Humanos , Concentração de Íons de Hidrogênio
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa