Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 168
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Cell ; 171(2): 358-371.e9, 2017 Oct 05.
Artigo em Inglês | MEDLINE | ID: mdl-28985563

RESUMO

Cancer cells consume glucose and secrete lactate in culture. It is unknown whether lactate contributes to energy metabolism in living tumors. We previously reported that human non-small-cell lung cancers (NSCLCs) oxidize glucose in the tricarboxylic acid (TCA) cycle. Here, we show that lactate is also a TCA cycle carbon source for NSCLC. In human NSCLC, evidence of lactate utilization was most apparent in tumors with high 18fluorodeoxyglucose uptake and aggressive oncological behavior. Infusing human NSCLC patients with 13C-lactate revealed extensive labeling of TCA cycle metabolites. In mice, deleting monocarboxylate transporter-1 (MCT1) from tumor cells eliminated lactate-dependent metabolite labeling, confirming tumor-cell-autonomous lactate uptake. Strikingly, directly comparing lactate and glucose metabolism in vivo indicated that lactate's contribution to the TCA cycle predominates. The data indicate that tumors, including bona fide human NSCLC, can use lactate as a fuel in vivo.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/metabolismo , Ácido Láctico/metabolismo , Neoplasias Pulmonares/metabolismo , Animais , Análise Química do Sangue , Linhagem Celular Tumoral , Ciclo do Ácido Cítrico , Modelos Animais de Doenças , Feminino , Ácidos Glicéricos/metabolismo , Xenoenxertos , Humanos , Masculino , Camundongos , Transportadores de Ácidos Monocarboxílicos/genética , Transportadores de Ácidos Monocarboxílicos/metabolismo , Transplante de Neoplasias , Simportadores/genética , Simportadores/metabolismo
2.
Cell ; 164(4): 681-94, 2016 Feb 11.
Artigo em Inglês | MEDLINE | ID: mdl-26853473

RESUMO

Non-small cell lung cancer (NSCLC) is heterogeneous in the genetic and environmental parameters that influence cell metabolism in culture. Here, we assessed the impact of these factors on human NSCLC metabolism in vivo using intraoperative (13)C-glucose infusions in nine NSCLC patients to compare metabolism between tumors and benign lung. While enhanced glycolysis and glucose oxidation were common among these tumors, we observed evidence for oxidation of multiple nutrients in each of them, including lactate as a potential carbon source. Moreover, metabolically heterogeneous regions were identified within and between tumors, and surprisingly, our data suggested potential contributions of non-glucose nutrients in well-perfused tumor areas. Our findings not only demonstrate the heterogeneity in tumor metabolism in vivo but also highlight the strong influence of the microenvironment on this feature.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/metabolismo , Carcinoma Pulmonar de Células não Pequenas/patologia , Neoplasias Pulmonares/metabolismo , Neoplasias Pulmonares/patologia , Microambiente Tumoral , Adulto , Idoso , Idoso de 80 Anos ou mais , Carcinoma Pulmonar de Células não Pequenas/irrigação sanguínea , Ciclo do Ácido Cítrico , Feminino , Glicólise , Humanos , Neoplasias Pulmonares/irrigação sanguínea , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons
3.
Ann Surg ; 2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38501239

RESUMO

OBJECTIVE: This study aimed to present the early and mid-term outcomes of fenestrated/branched thoracic endovascular aortic repair (f/bTEVAR) for aortic arch pathologies. BACKGROUND: f/bTEVAR represents a less invasive treatment option for aortic arch diseases. Previous published series showed decreased early mortality and morbidity compared to open repair. METHODS: A single-center retrospective analysis of consecutive patients, managed with f/bTEVAR (Cook Medical, Bloomington, IN, USA) between 01.09.11and 30.06.22 was conducted. Primary outcomes were technical success, 30-day mortality and stroke. Data during follow-up and factors affecting early mortality and stroke were analyzed. RESULTS: 209 patients were included (38.3% females; mean age 69.8±3.4years; mean aortic diameter 61±4.7 mm); 14.4% were managed urgently. Fenestrations/scallop configuration was used in 39.7%, branched devices in 55.5% and branch/scallop combination in 4.8%. Landing to zone 0 was performed in 65.5% and in zone 1 in 32.1%. Non-native aortas were used for landing in 39.2%. Technical success was 97.1% and 30-day mortality 9.5%. Strokes were identified in 10%; 5.7% major. Non-native proximal aortic landing zone was an independent protective factor for stroke (P=0.002). Post-operative stroke (P<0.001) and pericardial effusion (P<0.001) were independently related to 30-day mortality. The mean follow-up was 21±8 months. The estimated survival and freedom from reintervention rates were 79.5% (standard error; SE3.1%) and 47.1% (SE 4.3%) at 24months, respectively. CONCLUSIONS: f/bTEVAR presented high technical success and acceptable 30-day mortality. Non-native proximal landing zone was related to lower stroke rate. Half of patients needed a reintervention within the 24-month follow-up.

4.
J Vasc Surg ; 79(3): 457-468.e2, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38453660

RESUMO

BACKGROUND: Fenestrated and branched endovascular aortic repair (F/BEVAR) of thoracoabdominal aortic aneurysms (TAAAs) has shown high technical success and low early mortality rates. Aneurysm extent has been reported as a factor affecting outcomes. This study aimed to assess the early and midterm follow-up outcomes of patients managed by F/BEVAR for types I through III TAAAs. METHODS: A single-center retrospective analysis was conducted, including data from consecutive, elective and urgent (symptomatic and ruptured cases), patients treated for types I through III TAAAs, between October 1, 2011, and October 1, 2022, using F/BEVAR. Degenerative and postdissection TAAAs were included. Patients received prophylactic cerebrospinal fluid drainage (CSFD), except those under therapeutic anticoagulation, those who were hemodynamically unstable, or those with failed CSFD application. When an initial thoracic endovascular aortic repair was performed, as part of a staged procedure, no CSFD was used. Later stages and nonstaged procedures were performed under CSFD. Thirty-day mortality and major adverse events (MAEs) were analyzed. Kaplan-Meier estimates were used for follow-up outcomes. RESULTS: F/BEVAR for types I through III TAAAs was performed in 209 patients (56.9% males; mean age, 69.6 ± 3.2 years; mean aneurysm diameter, 65.2 ± 6.2 mm); 29.2% type I, 57.9% type II, and 12.9% type III. Urgent repair was performed in 26.7% of patients (56 cases; 23 ruptured and 33 symptomatic cases) and 153 were treated electively. Thirty-two patients (15.3%) were classified as American Society of Anesthesiologists (ASA) class IV. CSFD was used in 91% and staged thoracic endovascular aortic repair was performed in 51.2% of patients. Technical success was 93.8% (96.7% in elective vs 94.6% in urgent cases; P = .92). Thirty-day mortality was 11.0% (4.6% in elective vs 28.5% in urgent cases; P < .001) and MAEs were recorded in 17.2% of cases (7.8% in elective vs 42.8% in urgent cases; P < .001). Spinal cord ischemia rate was 20.5% (17.6% in elective vs 28.7% in urgent cases; P = .08), whereas 2.9% of patients presented paraplegia (1.3% in elective and 7.1% in urgent cases; P = .03). The mean follow-up was 16 ± 5 months. Survival was 75.0% (standard error, 4.0%) and freedom from reintervention was 73.3% (standard error, 4.4%) at 36 months. ASA IV and urgent repair were detected as independent factors related to early mortality and MAE, whereas ruptured aneurysm status was related to spinal cord ischemia evolution. CONCLUSIONS: Endovascular repair for types I through III TAAAs provides encouraging early outcomes in terms of mortality, MAE, and paraplegia, especially in an elective setting. Setting of repair and baseline ASA score should be taken into consideration during decision-making.


Assuntos
Aneurisma da Aorta Abdominal , Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Isquemia do Cordão Espinal , Masculino , Humanos , Idoso , Feminino , Correção Endovascular de Aneurisma , Prótese Vascular , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/efeitos adversos , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento , Procedimentos Endovasculares/efeitos adversos , Isquemia do Cordão Espinal/etiologia , Paraplegia/etiologia
5.
J Vasc Surg ; 2024 Oct 18.
Artigo em Inglês | MEDLINE | ID: mdl-39427719

RESUMO

OBJECTIVE: To evaluate the patency of bridging covered stents (BCS) bridged to inner branches in custom-made thoracoabdominal endografts. METHODS: Single-center retrospective study identifying all patients undergoing fenestrated or branched endovascular aortic repair (f/b EVAR) in whom the reno-visceral target vessels (TV) were bridged with a BCS to an inner branch of a custom made (CMD) endograft.. Technical success and perioperative complications were noted. Follow-up BCS patency were evaluated and in patients with follow-up, two groups based on BCS were created, a group with BCS occlusion and a group with BCS patent. Uni und multivariable analysis were performed to analyze factors related to visceral and renal bridging stent occlusion. RESULTS: From 2019-2022, 69 patients undergoing complex aortic repair had at least one TV bridged to an inner branch built into a CMD endograft. 86% of the grafts had only inner branches, whereas 14% had a mix of fenestrations for the visceral TV and inner branches for the renal arteries. Twenty-five percent of patients presented as urgency and received an endograft originally designed for another patient and available on our shelf at the time. 245 TVs were connected to inner branches: celiac trunk (CT): 54, superior mesenteric artery (SMA): 59, renal artery (RA): 132. Technical success was 99%. There was a 23% complication and 9% perioperative mortality rate. At follow-up, we identified 6% of visceral and 14% of renal BCS occlusions. The primary patency for RA BCS was 83% at 12 months and 58% at 24 months. For the CT-SMA BCS, Kaplan-Maier (KM) showed a patency of 99% and 96% at 12 and 24 months. In the univariate analysis a misaligned TV ostium (p 0.001), the postoperative BCS diameter on postoperative CTA (p 0.02) and the preoperative infrarenal aortic angle >60º (0.007) were correlated with RA BCS occlusion. In the multivariate analysis only the misaligned TV ostium (p 0.002) and infrarenal angle > 60° (p 0.01) were significantly correlated. CONCLUSIONS: In our series of complex aortic repair, the incorporation of inner branches to bridge TVs is associated with a high renal BCS occlusion rate. Improper alignment of the branches with the TV ostium and acute aortic angles might play a significant role. Further research on this technology is needed.

6.
J Vasc Surg ; 80(3): 621-629.e3, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38580160

RESUMO

OBJECTIVE: Fenestrated and branched thoracic endovascular repair (f/bTEVAR) have been successfully applied in patients with diverse aortic arch pathologies. The aim of this study is to present the early and mid-term outcomes of patients with native proximal aortic landing (NPAL) managed with f/bTEVAR. METHODS: A single-center retrospective analysis of patients with NPAL, managed with f/bTEVAR, between September 1, 2011, and June 30, 2022, was conducted. All patients were treated with custom-made devices (Cook Medical) with landing within Ishimaru zones 0 to 2. Primary outcomes were technical success, mortality, stroke, and retrograde type A dissection at 30 days. Follow-up outcomes were considered secondary. RESULTS: A total of 126 patients were included (69.8% males; mean age, 70.8 ± 4.2 years; 18.3% urgent). The main indications (60.4%) for repair were aortic arch (29.4%) and thoracoabdominal aortic aneurysms (31.0%). Seventy-two patients (57.1%) were managed with fTEVAR. Proximal landing in zone 0 and 1 was chosen in 97.6%. Technical success was 94.4%, and 30-day mortality was 11.9%. Strokes were diagnosed in 13.5% of patients and major strokes were identified in 7.9% cases. Retrograde type A dissection rate was 3.9%. The multivariate analysis confirmed landing in Ishimaru zone 0 as an independently related factor for stroke (P = .005), whereas stroke (P < .001), pericardial effusion (P < .001), and acute kidney injury (P < .001) were independently related to 30-day mortality. Mean follow-up was 17.5 ± 9.3 months. The estimated survival rate and the freedom from reintervention rate were 72.6% (standard error, 4.4%) and 46.4% (standard error, 6.0%) at 24-month follow-up, respectively. CONCLUSIONS: Stroke rate after endovascular arch repair was alarming among patients with NPAL. Proximal landing to zone 0 was related to higher risk of stroke. Reinterventions were common within the 24-month follow-up.


Assuntos
Aorta Torácica , Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Prótese Vascular , Procedimentos Endovasculares , Desenho de Prótese , Humanos , Masculino , Feminino , Estudos Retrospectivos , Idoso , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/mortalidade , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/mortalidade , Aorta Torácica/cirurgia , Aorta Torácica/diagnóstico por imagem , Fatores de Tempo , Resultado do Tratamento , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/mortalidade , Aneurisma da Aorta Torácica/diagnóstico por imagem , Fatores de Risco , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/mortalidade , Dissecção Aórtica/cirurgia , Dissecção Aórtica/mortalidade , Dissecção Aórtica/diagnóstico por imagem , Pessoa de Meia-Idade , Stents , Medição de Risco
7.
J Endovasc Ther ; : 15266028241231905, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38380515

RESUMO

INTRODUCTION: Data on target vessel (TV)-related outcomes in patients managed with branched thoracic endovascular aortic repair (BTEVAR) are limited. This study aimed to present the TV-related outcomes of BTEVAR in patients managed for aortic arch pathologies at 30 days and during follow-up. METHODS: A retrospective analysis of consecutive patients, managed between September 1, 2011, and June 30, 2022, with custom-made aortic arch endografts (Cook Medical, Bloomington, IN, USA), presenting at least one branch configuration, were eligible. Primary outcomes were technical success, TV-related patency, and reinterventions at 30 days. RESULTS: In total, 255 TVs were revascularized using branches: 107 innominate arteries (IAs), 108 left common carotid arteries (LCCAs), and 40 left subclavian arteries (LSAs). Covered stents were used as bridging stents of which 10.2% were balloon expandable. Relining, using bare-metal stents (BMS), was performed in 14.0% of IAs, 35.2% of LCCAs, and 22.5% of LSAs. Technical success on case basis was 99.2%; no failure was related to unsuccessful TV bridging. At 30 day follow-up, no TV occlusion was detected. In 5.6% of cases, a type Ic or III endoleak, attributed to TVs, was recorded. Two patients needed early branch-related reintervention. The mean follow-up was 18.3±9.2 months. Freedom from TV instability was 94.6% (standard error [SE] 2.5%] at 12 months. No TV stenosis or occlusion was detected up to 48 months of follow-up. Freedom from TV-related reinterventions was 95.4% [SE 2.4%] at 12 months. CONCLUSION: TV stenosis or occlusion in BTEVAR cases is rare and TV-related reinterventions and instability events are mainly attributed to type Ic and III endoleak formation. CLINICAL IMPACT: Previous studies focusing on target vessel (TV) outcomes after endovascular aortic arch repair are limited. In this study, including 255 TVs revascularized using branched arch devices, bridging was performed with covered stents, of which 90% were self-expanding. Relining was at the discretion of the operator and was 14% for the innominate, 35.2% for the left common carotid and 22.5% for the left subclavian artery branches. No 30-day occlusion was detected. The freedom from TV instability was almost 95% at 12 months. TV instability and reintervention were mainly attributed to endoleaks type Ic and IIIc.

8.
J Endovasc Ther ; : 15266028241267753, 2024 Aug 04.
Artigo em Inglês | MEDLINE | ID: mdl-39097800

RESUMO

INTRODUCTION: Left subclavian artery (LSA) preservation during thoracic endovascular aortic repair (TEVAR) has been related to low morbidity. This study investigated the incidence of LSA stent compression in patients managed with fenestrated endovascular arch repair (f-Arch) and evaluated the impact of anatomic and technical factors on LSA stent outcomes. METHODS: A single-center retrospective analysis of patients managed with single-fenestration devices (Cook Medical, Bloomington, IN, USA) for LSA preservation, between January 1, 2012 and November 30, 2023, was conducted. Anatomic (arch type, bovine arch, distance between the LSA and most proximal bone structure, left common carotid artery and aortic lesion, take-off angle, diameter, thrombus, calcification, dissection, tortuosity) and technical parameters (stent type, diameter, length, relining, post-dilation) were evaluated. Stent compression was any ≥50% stenosis (using center luminal line) of the stent compared with its initial diameter. Clinical outcomes included stroke and upper limb ischemia at 30 days and follow-up. Technical outcomes included stent compression and need for reintervention. RESULTS: Fifty-four cases were included. Only balloon-expandable covered stents were used, and relining during the index procedure was performed in 18%. No stroke or arm ischemia was recorded. One stent compression was detected at 30 days. During follow-up, no stroke or arm ischemia was diagnosed. Nine cases (18%) presented stent compression, with a mean time of stent-compression diagnosis at 18 months (interquartile range [IQR]=37, range=1-58 months) after the index procedure. Five (56%) underwent secondary relining. Follow-up after reintervention was uneventful. Lower distance to the nearest bone structure (compression group [CG]: 11.7±8.9 mm vs non-compression group [NCG]: 23.0±7.8 mm, p=0.003) and higher tortuosity index (CG: 1.3±0.4 vs NCG: 1.2±0.1, p=0.03) were associated with LSA stent compression. CONCLUSION: LSA stent compression in patients managed with f-Arch affected 1 in 5 cases, without clinical consequences. Distance to the nearest bone structure and higher tortuosity were associated with LSA stent compression. CLINICAL IMPACT: Fenestrated endovascular arch repair for the preservation of the left subclavian artery (LSA) in patients needing landing within the aortic arch has been performed with encouraging outcomes. This analysis showed that LSA stent compression is met in 18% of patients, without though any clinical consequence. Pre-operative anatomic parameters, as lower distance to the nearest bone structure and higher tortuosity index affect negatively LSA stent performance while stent parameters seem to have no impact.

9.
J Endovasc Ther ; : 15266028241266143, 2024 Jul 26.
Artigo em Inglês | MEDLINE | ID: mdl-39058090

RESUMO

PURPOSE: Repair of pararenal aneurysms poses a challenge, especially in an urgent setting. Despite the minimally invasive nature of the fenestrated/branched endovascular aortic repair, the technique may require extensive coverage of the aorta, increasing the risk of spinal cord ischemia. TECHNIQUE: A 68-year-old man was admitted with a rapid enlargement of an asymptomatic juxtarenal aortic aneurysm. A minimally invasive treatment with an off-the-shelf branched endovascular graft was planned. Before completing the aneurysm exclusion, an angiography highlighted a large lumbar artery, potentially significant for the perfusion of the spinal cord collateral network. Owing to this finding and an unsuccessful placement of the cerebrospinal fluid drainage, the procedure was staged and completed 5 days later using a physician-modified iliac branch device (IBD) for the segmental artery. The device was shortened and reversely loaded to obtain a cranially-oriented branch. A balloon-expandable covered stent was used to connect the retrograde branch (8 mm) to the lumbar artery (4 mm). Pre-discharge computed tomography (CT)-angiography confirmed the vessel patency. No neurological symptoms occurred. CONCLUSION: The use of a reversely-loaded IBD for segmental artery preservation appears feasible and safe. CLINICAL IMPACT: Intraoperative modification of an iliac branch device during an urgent branched endovascular aortic repair enabled preservation of a potentially critical segmental artery, thus reducing the risk of spinal cord ischemia. This adaptive interventional technique may also offer a strategy for preserving other anatomically significant vessels, such as accessory renal arteries, during complex aortic reconstructions in urgent settings.

10.
J Endovasc Ther ; : 15266028241266158, 2024 Jul 26.
Artigo em Inglês | MEDLINE | ID: mdl-39058232

RESUMO

PURPOSE: To describe the X-over reversed iliac extension technique in a patient with severe peripheral arterial disease (PAD) scheduled for inner branched endovascular aortic repair (iBEVAR). TECHNIQUE: A multimorbid 62-year-old male patient was planned for iBEVAR due to a 58 mm suprarenal aortic aneurysm. The patient had a previous right femoropopliteal bypass and stenting of the left iliac axis. At admission, he presented with recent onset severe left limb claudication, which was attributed to left iliac stent occlusion. To avoid the postoperative compression of the right common femoral artery (CFA) and preserve the patency of the bypass, a single left CFA access, followed by left iliac artery recanalization, was decided. The right iliac axis was catheterized with a Lunderquist wire using X-over access from the left CFA. An iliac extension (ZISL, 24-59, Cook Medical, Bloomington, USA) was reversed and resheathed on back-table and implanted in the right common iliac artery using the X-over technique. The left CFA access was used to complete the remaining steps of the procedure. The predischarge computed tomography angiography confirmed bilateral iliac artery and femoropopliteal bypass patency. CONCLUSION: The X-over reversed iliac extension technique may be applied in selected PAD patients, when undergoing complex endovascular aortic repair. CLINICAL IMPACT: As the number of patients with peripheral arterial disease (PAD) is expected to increase the upcoming decades, out of the box solutions may be needed to assist complex endovascular aortic management. The X over technique, which consist of the contralateral advancement of an on-table reversed iliac limb, was successfully applied in a patient with severe PAD and numerous previous peripheral interventions, who was managed with branched endovascular aortic repair . The X Over technique may provide an additional alternative in well-selected patients with demanding vascular access undergoing complex endovascular aortic procedures.

11.
J Endovasc Ther ; : 15266028241245341, 2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38597263

RESUMO

OBJECTIVES: Electrosurgery has been long used in endovascular procedures, with only case reports in the aortic field. Our aim is to present a case series with the use of an electrified wire to perform catheter-based electrosurgery by applying external current through an electrocautery pen. METHODS: Single-center retrospective case series of all patients undergoing complex aortic surgery from October 2020 to August 2023, in whom the electrified wire technique was used: (1) Perforation of a dissection flap or left subclavian artery (LSA) in situ endograft fenestration-a 0.014" polytetrafluoroethylene (PTFE) insulated guidewire is detached from the insulation with a scalpel at the end and a cautery pen is here attached with a clamp. A curved tip catheter or sheath is positioned against the aortic flap or the endograft (through a left brachial access in this case) and the wire pushed, crossing the flap by activating the electrocautery pen and (2) slicing a dissection flap ("powered cheese-wire technique")-after same preparation as above, the middle section of the 0.014 guidewire is removed from the PTFE and bent into a V-shape. Once in the aorta, the guidewire crosses from the true lumen (TL) to the false lumen (FL) and a through-and-through access is obtained. Sheaths are positioned against the flap from both sides and moved up or down while the electricity is activated, slicing the flap and communicating both lumens. Technical success and technical-related complications were evaluated. RESULTS: Eleven cases concerning aortic dissections and 1 case of aortic atresia were treated. Four patients presented urgently, whereas the rest were planned procedures. Seven cases underwent perforation of a dissection flap, 2 cases underwent the powered cheese-wire technique, in 2 cases for an LSA in situ fenestration, and in 1 case to cross an aortic atresia at the aortic isthmus. The technique was in all cases successfully applied. No complications related to the technique occurred. CONCLUSIONS: The "electrified wire" technique is a feasible and ready-available tool that can be safely used in complex aortic interventions, especially to perforate aortic tissue like dissection flaps or to perform in situ fenestrated repairs by perforation of the endograft fabric. CLINICAL IMPACT: The electrified wire technique described herein is a straightforward technique that uses readily available tools to perform electrosurgery. We present its use in complex aortic procedures. However, it could be envisioned for any vascular procedure that requires crossing of the vessel or even prosthetic material. As we have described in this series, when used along with an adequate properative planning, it can be a safe tool of great utility, as has already been demonstarted in the field of the interventional cardiology.

12.
J Endovasc Ther ; : 15266028241251985, 2024 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-38708984

RESUMO

PURPOSE: The treatment of thoracoabdominal aortic aneurysms (TAAAs) using branched endovascular aortic repair (BEVAR) is safe and effective. During deployment, the superior mesenteric artery (SMA) branch can unintentionally open into the celiac trunk (CT) ostium and switched catheterization of the SMA from the CT branch and the CT from the SMA branch can be used as an alternative technique in these cases. This study aimed to investigate the outcome of exchanging the intended target vessels (TVs) for the CT and SMA branches during BEVAR. MATERIALS AND METHODS: A single-center retrospective analysis of patients with TAAAs who underwent BEVAR, using off-the-shelf or custom-made devices (CMDs), with an unintended exchange of TVs for the CT and SMA branches was performed. RESULTS: Between 2014 and 2023, 397 patients were treated with BEVAR for TAAA. Eighteen (4.5%) of those patients were treated with an exchange of TVs for the CT and SMA branches. T-branch was used in 9 cases (50%) and the remaining patients were treated with CMDs. Twelve patients were treated electively, 3 were symptomatic and 3 presented with rupture. Of 36 mesenteric TVs in those 18 patients, 34 (94%) were catheterized successfully, including all 18 SMAs and 16 of the 18 CTs. No branch stenosis or occlusion of the switched mesenteric TVs was detected during follow-up. During 30-day follow-up, 3 patients died and during a median follow-up of 3 (interquartile range [IQR]: 1-15) months 3 more patients died. None of the deaths or the 2 unintended reinterventions was induced by the mesenteric TV exchange. The median hospital stay was 14 (IQR: 9-22) days with a median of 4 (IQR: 2-11) days at the intensive care unit. CONCLUSION: The exchange of the mesenteric TVs for the CT and SMA branches during BEVAR with off-the-shelf and CMD endografts is feasible with good TV patency and freedom from TV-related reinterventions. This alternative technique should be considered in selected cases when direct catheterization via the intended branch is deemed more time-consuming or not feasible. CLINICAL IMPACT: This is the first description of using an exchange of target vessels for the celiac trunk and the superior mesenteric artery branches in patients with thoracoabdominal aortic aneurysms undergoing BEVAR, using off-the-shelf or custom-made devices. The high success rate as well as the good clinical results without any branch stenosis or occlusion during follow-up highlight the feasibility of this alternative technique. It could help in challenging cases when catheterization of the intended target vessels is not possible or too time consuming, resulting in higher success rates of BEVAR and better clinical results.

13.
Eur J Vasc Endovasc Surg ; 67(6): 895-902, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38320646

RESUMO

OBJECTIVE: Iliac branch devices (IBDs) have shown good results but there is little evidence for the risk of internal iliac artery (IIA) endoleak, so there are no clear recommendations on the maximum diameter it should be. Based on limited evidence, it was hypothesised that an IIA of ≥ 11 mm in diameter presents an increased risk of type Ic endoleak. METHODS: This was a single centre, retrospective case control study. Patients undergoing an IBD with the main trunk of the IIA as the target vessel, between 2015 and 2021, were identified. Two groups were created: those with a main trunk diameter of < 11 mm; and those with a diameter of ≥ 11 mm. Technical success, freedom from type Ic endoleak, and re-intervention rates were compared. A receiver operating characteristic (ROC) curve was performed to show a cutoff IIA diameter value for risk of type Ic endoleak. Multivariate analysis was performed to assess the risk of type Ic endoleak and the presence of calcification, stenosis, and landing zone length in the IIA. RESULTS: There were 182 IBDs identified. The dilated IIA group (54 IBDs) had significantly lower technical success (91% vs. 98.4%; p = .002), lower freedom from type Ic endoleak (77% vs. 97.1% at 24 months; p = .001), and lower freedom from re-interventions (70% vs. 92.4% at 24 months; p = .002). The ROC curve showed that 10.5 mm was the cutoff diameter for type Ic endoleak. Moderate or severe calcification as well as landing zone length < 5 mm also correlated with type Ic endoleak. CONCLUSION: IBDs have a statistically significantly higher rate of technical failure, lower freedom from type Ic endoleak, and lower freedom from re-intervention when the IIA is ≥ 11 mm in diameter.


Assuntos
Implante de Prótese Vascular , Endoleak , Procedimentos Endovasculares , Artéria Ilíaca , Humanos , Endoleak/etiologia , Estudos Retrospectivos , Masculino , Feminino , Idoso , Artéria Ilíaca/cirurgia , Artéria Ilíaca/diagnóstico por imagem , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Fatores de Risco , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Idoso de 80 Anos ou mais , Prótese Vascular , Medição de Risco , Resultado do Tratamento , Estudos de Casos e Controles , Dilatação Patológica , Desenho de Prótese , Pessoa de Meia-Idade , Stents/efeitos adversos
14.
Eur J Vasc Endovasc Surg ; 68(3): 315-323, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38677467

RESUMO

OBJECTIVE: Female sex is a risk factor for adverse events after endovascular aortic repair. Sex comparative early and midterm outcomes of fenestrated and branched endovascular aortic arch repair (F/B-Arch) are presented. METHODS: A single centre retrospective sex comparative analysis of consecutive patients managed with F/B-Arch was conducted according to STROBE. Primary outcomes were sex comparative technical success, death, and cerebrovascular morbidity at 30 days. Kaplan-Meier estimates were used for follow up outcomes. RESULTS: Among 209 patients, 38.3% were women. Coronary artery disease (p < .001) and previous myocardial infarction (p = .01) were more common in women. Non-native proximal aortic landing was higher in women (women: 51.3%; men: 31.8%, p = .005) and the aortic dissection rate was lower (28.8% vs. 48.1%, p = .005). Proximal landing to Ishimaru zones showed no difference (zone 0: p = .18; zone 1: p = .47; zone 2: p = .39). Graft configurations were equally distributed. In total, 416 supra-aortic trunks were bridged. The median number of revascularisations per patient was two (interquartile range 1, 3), with no difference between sexes (p = .54). Technical success (women: 97.5%; men: 96.9%, p = .80), 30 day mortality rate (women: 10%; men: 9.3%, p = .86), and cerebrovascular morbidity (women: 11.3%; men: 17.1%, p = .25) were similar. Women presented more access related complications (women: 32.5%; men: 16.3%, p = .006), without affecting access related re-interventions (p = .55). Survival (women: 81.1%, 95% confidence interval [CI] 76.3 - 85.9%; men: 79.8%, 95% CI 76.0 - 83.6%) and freedom from re-intervention (women: 56.6%, 95% CI 50.4 - 62.8%; men: 55.3%, 95% CI 50.1 - 60.5%) at 12 months were similar (log rank, p = .40 and p = .41, respectively). CONCLUSION: Both sexes presented similar outcomes after F/B-Arch. Appropriate patient selection may decrease the effect of sex in F/B-Arch outcomes.


Assuntos
Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Masculino , Feminino , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/mortalidade , Estudos Retrospectivos , Idoso , Aorta Torácica/cirurgia , Aorta Torácica/diagnóstico por imagem , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/mortalidade , Resultado do Tratamento , Fatores Sexuais , Pessoa de Meia-Idade , Fatores de Risco , Prótese Vascular , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/epidemiologia , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/mortalidade , Stents , Idoso de 80 Anos ou mais , Desenho de Prótese , Fatores de Tempo , Dissecção Aórtica/cirurgia , Dissecção Aórtica/mortalidade
15.
Eur J Vasc Endovasc Surg ; 68(3): 325-334, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38697255

RESUMO

OBJECTIVE: Fenestrated or branched endovascular aortic repair (F/B-EVAR) is a valuable treatment in patients with chronic post-dissection thoraco-abdominal aneurysm (PD-TAAA). This study aimed to analyse early and follow up outcomes of F/B-EVAR in these patients. METHODS: Thirty day and follow up outcomes of consecutive patients with PD-TAAA treated with F/B-EVAR in a tertiary centre over eight years were analysed retrospectively. All patients presenting with PD-TAAA and managed with F/B-EVAR were eligible. A modified Crawford's classification system was used. Thirty day mortality and major adverse event (MAE) rates were analysed. Time to event data were estimated with Kaplan-Meier survival analysis. RESULTS: Fifty five patients (80% men, mean age 63.7 ± 7.7 years) were included: 12 (22%) were managed urgently; 25 (46%) for chronic type B aortic dissection; and the remainder for residual type A aortic dissection. Of these patients, 88% had undergone previous thoracic endovascular aortic repair. Prophylactic cerebrospinal fluid drainage (CSFD) was used in 91%. Fifteen (27%) patients were treated with F-EVAR, nine (16%) with fenestrations and branches, and 31 (56%) with B-EVAR. False lumen adjunctive procedures were used in 56%. Technical success was achieved in 96% of patients. The thirty day mortality rate was 7% and MAE rate was 20%. Spinal cord injury (SCI) grades 1 - 3 and grade 3 rates were 13% and 2%, respectively. Mean follow up was 33.0 ± 18.4 months. Survival and freedom from unscheduled re-intervention were 86% (standard error [SE] 5%) and 55% (SE 8%) at 24 months, respectively. Freedom from target vessel stenosis and occlusion was higher in F-EVAR at the 12 month follow up (p = .006) compared with B-EVAR. CONCLUSION: Fenestrated or branched endovascular repairs in patients with PD-TAAA showed high technical success, with acceptable early mortality and MAE rates. The SCI rate was > 10%, despite CSFD use and staged procedures. Almost a half of patients needed an unscheduled re-intervention within 24 months after F/B-EVAR.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Procedimentos Endovasculares , Complicações Pós-Operatórias , Humanos , Masculino , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/mortalidade , Feminino , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Procedimentos Endovasculares/métodos , Pessoa de Meia-Idade , Dissecção Aórtica/cirurgia , Dissecção Aórtica/mortalidade , Estudos Retrospectivos , Idoso , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Implante de Prótese Vascular/métodos , Resultado do Tratamento , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/epidemiologia , Prótese Vascular , Fatores de Tempo , Stents , Fatores de Risco , Desenho de Prótese , Correção Endovascular de Aneurisma
16.
Pediatr Nephrol ; 39(3): 745-748, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37874356

RESUMO

Post-infectious glomerulonephritis (PIGN) is an immune complex mediated glomerular injury occurring because of an infection, most commonly with group A beta-hemolytic streptococcus in children. C3 glomerulopathy (C3G) is a distinct clinicopathological entity occurring secondary to dysregulation of alternate complement pathway encompassing both C3 glomerulonephritis (C3GN) and dense deposit disease (DDD). While most patients with PIGN attain complete remission with normalized complement levels by 6-8 weeks after presentation, patients with C3G continue to have hypocomplementemia with high rates of progressive kidney disease. Here, we report a patient diagnosed with dense deposit disease after his initial presentation with PIGN three years prior. While current literature continues to explore the overlapping and distinguishing features of PIGN and C3G, including how underlying defects in the alternate complement pathway may commonly contribute to both diseases, this case further exemplifies the importance of recognizing the clinico-pathogenic features of PIGN and C3G in pediatric patients with glomerulonephritis.


Assuntos
Glomerulonefrite Membranoproliferativa , Glomerulonefrite , Nefropatias , Humanos , Criança , Complemento C3 , Glomerulonefrite/diagnóstico , Glomerulonefrite/etiologia , Glomérulos Renais/patologia , Nefropatias/patologia
17.
Ann Vasc Surg ; 99: 193-200, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37805170

RESUMO

BACKGROUND: Infective native aortic aneurysms (INAAs), formerly called mycotic aneurysms, remain an uncommon disease with significant heterogeneity among cases; hence, there is lack of solid evidence to opt for the best treatment strategy. The present study aims to describe a 20-year experience at a single institution treating this uncommon condition. METHODS: Retrospective study of all patients treated for INAA at a single academic hospital in Santiago, Chile, between 2002 and 2022. Clinical characteristics are described, as well as operative outcomes per type of treatment. Nonparametric Mann-Whitney U-test or Kruskal-Wallis tests were performed when appropriate, and results were reported as median and ranges. Survival at given timeframes was determined by a Kaplan-Meier curve, with analysis performed through a Cox regression model. RESULTS: During the study period, 1,798 patients underwent aortic procedures at our center, of which 35 (1.9%) were treated for INAA. Of them, 25 (71.4%) were male. One patient had 2 INAAs. Median age was 69.5 years (range: 34-89 years). Of the 36 INAAs, the most frequent location was the abdominal and thoracic aorta in 20 (55.5%) and 11 (30.5%) cases, respectively, followed by the iliac arteries in 4 (11.1%) cases. One (2.7%) patient presented a thoracoabdominal INAA. Overall, endovascular treatment associated with long-term antibiotics was used in 20 (57.1%) patients: 4 of them underwent hybrid treatment. Fifteen (42.8%) patients underwent direct aortic debridement followed by in situ or extra anatomic revascularization. There was a significant difference in age between both treatment strategies (a median of 76.5 years for endovascular versus a median of 57 years for open, P = 0.011). The median hospital stay was 15 days (range: 2-70 days). The early complications rate (<30 postoperative days) was 20% (n = 7). Early mortality rate (inhospital or before postoperative 30 days) was 14.2% (n = 5). Median follow-up was 33 months (range: 6-216 months). The overall survival rates at 1, 3, and 5 years were 69.9% (standard error [SE] 8.0), 61.7% (SE 9.8), and 50.9% (SE 11.8), respectively. Five-year survival rate of patients undergoing endovascular treatment compared with open approach was 45.9% (SE 15.1) versus 80.0% (SE 17.8), respectively (P = 0.431). There were no significant differences in survival between open and endovascular treatment, hazard ratio 3.58 (confidence interval 95%: 0.185-1.968, SE ± 0.45 P = 0.454). CONCLUSIONS: Patients treated by endovascular approach were older than patients treated by open approach. Even though, the open group had a higher 5-year survival rate than the endovascular group, not statically significance differences were found between treatments.


Assuntos
Aneurisma Infectado , Aneurisma da Aorta Abdominal , Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Masculino , Idoso , Feminino , Aneurisma Infectado/diagnóstico por imagem , Aneurisma Infectado/cirurgia , Chile , Estudos Retrospectivos , Resultado do Tratamento , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Complicações Pós-Operatórias/etiologia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/etiologia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/etiologia , Fatores de Risco
18.
Vascular ; : 17085381241289811, 2024 Oct 04.
Artigo em Inglês | MEDLINE | ID: mdl-39364914

RESUMO

PURPOSE: To describe the technique of off-centering a balloon-expandable covered stent for selective occlusion of a distal entry tear (ET) in a patient, conservatively treated for chronic type B aortic dissection (cTBAD), presenting FL expansion. TECHNIQUE: A 63-year-old male, with conservatively managed cTBAD, presented at follow-up with FL partial thrombosis and expansion (thoracic aorta FL from 21 mm to 27 mm and abdominal aorta FL from 11 mm to 15 mm in 6 months). No proximal ET was identifiable. Distal FL perfusion was caused by an ET in the abdominal aorta feeding a 2 mm accessory renal artery (ARA). As the aortic diameter was below the threshold for endovascular repair, a selective occlusion of the distal ET and ARA was planned. A balloon-expandable covered stent was modified by off-centering the covered stent proximally and resulting in a funnel-shape occluder after deployment across the ET into the ARA. To prevent type Ic endoleak due to possible FL expansion caused by an intra-operatively detected phrenic artery (PA), coils were deployed into the lumen of the modified stent and the ARA. The pre-discharge computed tomography angiography showed exclusion of both the ARA and ET and a type 2 endoleak from the PA. CONCLUSION: A balloon-expandable covered stent can be modified by off-centering the covered stent resulting in a funnel shape to adapt to different diameter requirements.

19.
J Endovasc Ther ; : 15266028231208657, 2023 Oct 30.
Artigo em Inglês | MEDLINE | ID: mdl-37902437

RESUMO

OBJECTIVE: To report on the outcomes of patients undergoing an iliac branch device implantation after previous open or endovascular aorto-biliac repair, using exclusively femoral access for catheterization and delivery of the covering stent to the hypogastric artery. METHODS: Single-center retrospective study in which all patients in whom an iliac branch device was implanted after previous open or endovascular aorto-biliac repair were identified. Patients in whom the hypogastric artery catheterization and delivery of the bridging cover stent were achieved via exclusive femoral access were included. Different techniques were used based on surgeon preference. Technical success and access-related complications, as well as iliac branch device endoleak or occlusions during follow-up, were evaluated. RESULTS: From 2015 to 2021, 28 patients with a prior open or endovascular aorto-biliac repair underwent 34 iliac branch device implantations. Most (71%) had juxtarenal or thoracoabdominal aortic aneurysms, 82% had common iliac artery aneurysms, and 25% had hypogastric artery aneurysms. Bilateral iliac branch device implantations were performed in 21% of the patients, and in 26% of cases, landing in the superior gluteal artery was obtained. An "up-and-over" technique from the contralateral groin was used in 65% of the cases, and a steerable sheath in 35%. Technical success was 94%, with no complications related to access or technique to catheterize and deliver the stents in the hypogastric artery. The cohort had 20% of major complications, with 3 perioperative deaths. Kaplan-Meier estimated an iliac branch device freedom from occlusion and endoleak was 92% and 83% at 2 years. CONCLUSIONS: The implantation of an iliac branch device over previous aortic or open endografts involving the aortic bifurcation is feasible and safe. We suggest using a femoral approach as the primary access of choice. CLINICAL IMPACT: In this study we present 28 patients with previous aortoiliac grafts in which iliac branch devices were performed as a subsequent step.We demonstrated the feasibility of the technique despite the difficulty of crossing a neobifurcation, with a steep angle, without complications associated with the technique. Based on our experience, we recommend transfemoral access as the first option for bypassing the hypogastric artery stent, preserving upper extremity access and its possible complications.

20.
J Endovasc Ther ; 30(1): 29-33, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35018862

RESUMO

PURPOSE: The purpose of this study was to describe the use of a wire and catheters embedded with optical fiber (Fiber Optic RealShape [FORS]) to catheterize tortuous target vessels avoiding radiation. TECHNIQUE: A virtual biplane vies was simulated coupling traditional x-ray system, preoperative CT scan, and FORS system to treat an isolated hypogastric aneurysm. Despite the complex anatomy, catheterization of all target vessels was possible in 12 minutes with 19 seconds of fluoroscopy time (Radiation Exposure 3.8 mGy×cm2). A minimal invasive endovascular exclusion of the aneurysm was achieved through selective coil-embolization of the iliolumbar artery and implantation of balloon expandable covered stents, thus preserving the perfusion of the superior gluteal artery. CONCLUSION: FORS guidance allowed catheterization of a target vessel with challenging anatomy with a low radiation exposure.


Assuntos
Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Procedimentos Endovasculares/efeitos adversos , Resultado do Tratamento , Cateterismo , Prótese Vascular , Stents , Tecnologia
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa