Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
J Endovasc Ther ; 30(4): 571-579, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35414228

RESUMO

PURPOSE: To compare the long-term outcomes of the most widely used third-generation stent grafts, the Endurant and Excluder stent grafts, in Japanese patients using a multicenter registry. MATERIALS AND METHODS: A retrospective analysis of endovascular aneurysm repairs for abdominal aortic and iliac artery aneurysms using either the Endurant or the Excluder stent grafts from January 2012 to July 2019 at 10 Japanese hospitals was performed. RESULTS: A total of 332 and 378 repairs using the Endurant and Excluder stent grafts, respectively, were analyzed. Although the patients' characteristics were generally similar in the two groups, the Endurant group exhibited significantly shorter (Endurant: 31.5±18.6 mm, Excluder: 37.4±21.0 mm; p<0.001), larger (Endurant: 22.4±4.2 mm, Excluder: 21.7±3.8 mm; p=0.029), and more reversed tapered (Endurant: 12.1%, Excluder: 5.8%; p=0.003) proximal necks. The incidence of instructions for use (IFU) violations was similar between the two groups (Endurant: 59.0%, Excluder: 54.5%; p=0.223). However, the Endurant group had significantly more proximal neck-related IFU violations (54.1% and 46.3%, respectively; p=0.039), more access-related IFU violations (8.1% and 4.0%, respectively; p=0.019), and fewer bilateral hypogastric artery embolizations (5.1% and 9.3%, respectively; p=0.035) compared with the Excluder group. The incidence of intraoperative (Endurant: 3.6%, Excluder: 3.7%; p=0.950) and perioperative complications (Endurant: 3.6%, Excluder: 3.4%, p=0.899) was equivalent in the two groups. However, there was a significantly higher incidence of postoperative type II endoleaks in the Excluder group (Endurant: 28%, Excluder: 46.0%, p<0.001). Aneurysm sac regression was more frequent in the Endurant group (Endurant: 40.7%, Excluder: 31.7%, p=0.013). The Endurant group also had significantly higher rates of sac increase (Endurant: 13.0%, Excluder: 7.7%, p=0.020). Kaplan-Meier curve and log-rank analyses revealed no statistical differences in late complications (p=0.868) and overall survival (p=0.926). CONCLUSIONS: There were no statistically significant differences between the Endurant and the Excluder stent grafts in terms of intraoperative, perioperative, and late complication rates; however, the anatomical characteristics of the patients were significantly different.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Stents , Correção Endovascular de Aneurisma , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/complicações , Estudos Retrospectivos , População do Leste Asiático , Fatores de Risco , Procedimentos Endovasculares/efeitos adversos , Desenho de Prótese , Resultado do Tratamento
2.
Eur J Vasc Endovasc Surg ; 58(6): 839-847, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31607678

RESUMO

OBJECTIVE/BACKGROUND: It was hypothesised that a helical stent with expanded polytetrafluoroethylene (ePTFE) grafts could provide a preventive effect for external iliac artery (EIA) limb occlusion following endovascular aortic aneurysm repair (EVAR). Therefore, a post-hoc analysis of a Japanese multicentre database was conducted to assess the impact of the stent graft design on EIA limb occlusion rates. METHODS: Patients who underwent EVAR with EIA limb deployment between 2008 and 2016 were evaluated. The stent graft limbs were divided into two groups: group A comprised stent graft limbs made of a helical stent with ePTFE grafts (Excluder; n = 255), and group B comprised stent graft limbs made of a Z stent with polyester grafts (Zenith, Flex and Endurant; n = 173). The main outcome was the incidence of limb occlusion and severe limb stenosis (EIA related limb complications). The risk factors for EIA related limb complications were analysed and the midterm results between groups A and B compared. Fine-Gray generalisation of the proportional hazards model was used after propensity score matching to calculate the hazard ratio (HR). RESULTS: One complication occurred in group A and 10 complications occurred in group B. The risk factors for EIA related limb complications for the entire group were a stent graft limb size ≤10 mm (HR 5.41; p = .01) and inclusion in group B (HR 14.9; p = .009). After propensity matching, group A (n = 159) was matched with group B (n = 159). The cumulative incidence function of EIA related limb complications at five years was 0.66% in group A and 7.8% in group B (HR 8.67; p = .039). CONCLUSION: Stent graft design can affect limb patency in EIA limb deployment. When EIA limb deployment is necessary for patients with a small EIA, such as Japanese patients, stent graft limbs made of a helical stent with ePTFE should be used to reduce the risk of limb occlusion.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Arteriopatias Oclusivas/epidemiologia , Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Oclusão de Enxerto Vascular/epidemiologia , Artéria Ilíaca/patologia , Desenho de Prótese/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Arteriopatias Oclusivas/diagnóstico por imagem , Arteriopatias Oclusivas/etiologia , Angiografia por Tomografia Computadorizada , Procedimentos Endovasculares/instrumentação , Feminino , Seguimentos , Oclusão de Enxerto Vascular/diagnóstico por imagem , Oclusão de Enxerto Vascular/etiologia , Humanos , Artéria Ilíaca/diagnóstico por imagem , Imageamento Tridimensional , Japão/epidemiologia , Extremidade Inferior , Masculino , Estudos Prospectivos , Medição de Risco , Fatores de Risco , Stents/efeitos adversos , Resultado do Tratamento
3.
Circ J ; 80(6): 1452-9, 2016 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-27118619

RESUMO

BACKGROUND: Spontaneous isolated superior mesenteric artery (SMA) dissection is a rare condition, and its clinical and angiographic courses are poorly defined. We aimed to monitor the morphological characteristics of spontaneous isolated SMA dissection using computed tomography (CT) over 2 years of follow-up, including the recovery process via vascular remodeling, and identify the factors that affect vascular remodeling using univariate analysis. METHODS AND RESULTS: We retrospectively reviewed the medical records and morphological findings of 59 consecutive patients with spontaneous isolated SMA dissection between October 2007 and July 2014, which included 36 symptomatic and 23 asymptomatic patients. Surgical intervention with open laparotomy was required in 3 patients during the follow-up period; 41 patients who received conservative treatment were followed up over 2 years with regular CT. Complete remodeling was achieved in 16 of 25 symptomatic patients who were treated conservatively (64.0%). A patent false lumen and aneurysmal formation on an initial CT scan were identified as negative factors that affected remodeling in patients with spontaneous isolated SMA dissection. CONCLUSIONS: Conservative management of spontaneous isolated SMA dissection is associated with a good prognosis, both clinically and morphologically. Surgical intervention is only required in patients with severe intestinal ischemia or rapid aneurysmal enlargement. (Circ J 2016; 80: 1452-1459).


Assuntos
Dissecção Aórtica/diagnóstico por imagem , Tratamento Conservador , Artéria Mesentérica Superior/patologia , Tomografia Computadorizada por Raios X , Idoso , Feminino , Seguimentos , Humanos , Masculino , Artéria Mesentérica Superior/diagnóstico por imagem , Pessoa de Meia-Idade , Estudos Retrospectivos , Remodelação Vascular
4.
Transplantation ; 75(6): 878-84, 2003 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-12660518

RESUMO

BACKGROUND: The authors previously showed that intratracheal delivery (ITD) of donor splenocytes induced prolonged survival of fully allogeneic cardiac grafts in mice. In this study, this treatment protocol was combined with blockade of the CD40 pathway in an attempt to induce operational tolerance. METHODS: CBA mice were given donor splenocytes (1x107) or Kb peptide (100 microg) by ITD with or without antibody specific for mouse CD40 ligand (MR1, 200 microg) 7 days before transplantation of a C57BL/10 heart. Also, splenocyte (5 x 107) from primary recipient CBA mice given ITD of donor splenocytes or Kb peptide plus MR1 were adoptively transferred into naive CBA secondary recipients 7 days after the pretreatment and C57BL/10 hearts were transplanted into those recipients the same day. RESULTS: ITD of donor splenocytes and Kb peptide induced prolonged survival of cardiac grafts (median survival time [MST], 74 and 56 days, respectively), whereas naive control mice and mice pretreated with syngeneic splenocytes had acute graft rejection (MST in both groups, 7 days). When MR1 was included, all grafts survived indefinitely (>200 days), but mice pretreated with MR1 alone had graft rejection (MST, 54 days). Mice bearing cardiac grafts had acceptance of skin grafts from C57BL/10 but not BALB/c mice, demonstrating that operational tolerance was induced. Secondary recipients given adoptive transfer of splenocytes from primary recipients of the combined treatment had acceptance of C57BL/10 grafts, suggesting that regulatory cells were generated within 7 days of pretreatment. CONCLUSIONS: ITD of donor splenocytes or Kb peptide under blockade of the CD40 pathway induced operational tolerance and generated regulatory cells.


Assuntos
Ligante de CD40/imunologia , Sobrevivência de Enxerto/imunologia , Transplante de Coração/imunologia , Transplante de Coração/mortalidade , Isoantígenos/farmacologia , Transferência Adotiva , Animais , Anticorpos Monoclonais/farmacologia , Antígenos CD40/imunologia , Células Cultivadas , Citocinas/biossíntese , Linfócitos/citologia , Linfócitos/metabolismo , Masculino , Camundongos , Camundongos Endogâmicos BALB C , Camundongos Endogâmicos C57BL , Camundongos Endogâmicos CBA , Transplante de Pele , Baço/citologia , Taxa de Sobrevida , Traqueia
5.
Transplantation ; 74(5): 732-8, 2002 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-12352894

RESUMO

BACKGROUND: The mechanism of hyporesponsiveness induced by intratracheal (IT) delivery of alloantigen was examined and its effect on cardiac graft survival was assessed in studies in mice. METHODS: In CBA (H2 ) mice, donor splenocytes were given by IT delivery 7 days before transplantation of a C57BL/10 (H2 ) heart. To determine whether regulatory cells were involved in hyporesponsiveness, splenocytes from mice given IT delivery of alloantigen and antibodies for B7-1, B7-2, or CTLA4 were adoptively transferred to naïve secondary recipients 7 days after delivery; those recipients underwent heart transplantation the same day. Effects on cell proliferation and cytokine production of splenocytes from mice given IT delivery of alloantigen were examined in mixed leukocyte cultures (MLC). RESULTS: Cardiac graft survival was significantly prolonged in mice given IT delivery of alloantigen (median survival time [MST], 81 days); those given syngeneic splenocytes rejected grafts acutely (MST, 7 days; P<0.05). Adoptive transfer of splenocytes also significantly prolonged survival of cardiac grafts in secondary recipients (MST, 62 days). When B7-1, B7-2, or CTLA4 antibody was combined with IT delivery of alloantigen in the first recipient, all grafts were rejected within 14 days in second recipients after adoptive transfer. In mixed leukocyte cultures, splenocytes from these mice did not respond to alloantigen and production of interleukin-4 and interleukin-10 was increased. CONCLUSIONS: Donor splenocytes delivered IT induced hyporesponsiveness and regulatory cells in our animal model, and such induction was dependent on B7-1, B7-2, and CTLA4 signals.


Assuntos
Transferência Adotiva , Antígenos de Diferenciação/imunologia , Antígeno B7-1/imunologia , Sobrevivência de Enxerto/imunologia , Transplante de Coração/imunologia , Imunoconjugados , Fragmentos Fc das Imunoglobulinas/imunologia , Isoantígenos/imunologia , Transfusão de Linfócitos , Linfócitos/imunologia , Abatacepte , Administração Oral , Animais , Antígenos CD , Antígeno CTLA-4 , Terapia de Imunossupressão/métodos , Isoantígenos/administração & dosagem , Transfusão de Linfócitos/métodos , Masculino , Camundongos , Camundongos Endogâmicos BALB C , Camundongos Endogâmicos C57BL , Camundongos Endogâmicos CBA , Baço/imunologia , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa