Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
N Engl J Med ; 388(23): 2121-2131, 2023 Jun 08.
Artigo em Inglês | MEDLINE | ID: mdl-37285526

RESUMO

BACKGROUND: Data showing the efficacy and safety of the transplantation of hearts obtained from donors after circulatory death as compared with hearts obtained from donors after brain death are limited. METHODS: We conducted a randomized, noninferiority trial in which adult candidates for heart transplantation were assigned in a 3:1 ratio to receive a heart after the circulatory death of the donor or a heart from a donor after brain death if that heart was available first (circulatory-death group) or to receive only a heart that had been preserved with the use of traditional cold storage after the brain death of the donor (brain-death group). The primary end point was the risk-adjusted survival at 6 months in the as-treated circulatory-death group as compared with the brain-death group. The primary safety end point was serious adverse events associated with the heart graft at 30 days after transplantation. RESULTS: A total of 180 patients underwent transplantation; 90 (assigned to the circulatory-death group) received a heart donated after circulatory death and 90 (regardless of group assignment) received a heart donated after brain death. A total of 166 transplant recipients were included in the as-treated primary analysis (80 who received a heart from a circulatory-death donor and 86 who received a heart from a brain-death donor). The risk-adjusted 6-month survival in the as-treated population was 94% (95% confidence interval [CI], 88 to 99) among recipients of a heart from a circulatory-death donor, as compared with 90% (95% CI, 84 to 97) among recipients of a heart from a brain-death donor (least-squares mean difference, -3 percentage points; 90% CI, -10 to 3; P<0.001 for noninferiority [margin, 20 percentage points]). There were no substantial between-group differences in the mean per-patient number of serious adverse events associated with the heart graft at 30 days after transplantation. CONCLUSIONS: In this trial, risk-adjusted survival at 6 months after transplantation with a donor heart that had been reanimated and assessed with the use of extracorporeal nonischemic perfusion after circulatory death was not inferior to that after standard-care transplantation with a donor heart that had been preserved with the use of cold storage after brain death. (Funded by TransMedics; ClinicalTrials.gov number, NCT03831048.).


Assuntos
Morte Encefálica , Transplante de Coração , Obtenção de Tecidos e Órgãos , Adulto , Humanos , Sobrevivência de Enxerto , Preservação de Órgãos , Doadores de Tecidos , Morte , Segurança do Paciente
2.
Clin Transplant ; 38(4): e15296, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38545928

RESUMO

INTRODUCTION: Clinical success of donation after circulatory death (DCD) heart transplantation is leading to growing adoption of this technique. In comparison to procurement from a brain-dead donor, DCD requires additional resources. The economic impact of DCD heart transplantation from the hospital perspective is not well known. METHODS: We compared the financial data of patients who received DCD allografts to those who received a DBD organ at our institution from January 1, 2021 to December 31, 2022. We also compared the cost of ex-situ machine perfusion to in-situ organ perfusion employed during DCD recovery. RESULTS: We performed 58 DBD and 22 DCD heart-alone transplantations during the study period. Out of 22 DCD grafts, 16 were recovered with thoracoabdominal normothermic regional perfusion (TA-NRP) and six with direct procurement followed by normothermic machine perfusion (DP-NMP). The contribution margin per case for DBD versus DCD was $234,362 and $235,440 (P = .72). The direct costs did not significantly differ between the two groups ($171,949 and 186,250; P = .49). In comparing the two methods of procuring hearts from DCD donors, the direct cost of TA-NRP was $155,955 in comparison to $223,399 for DP-NMP (P = .21). This difference translated into a clinically meaningful but not statistically significant greater contribution margin for TA-NRP ($242, 657 vs. $175,768; P = .34). CONCLUSIONS: Our data showed that the adoption of DCD procurement did not have a negative financial impact on the contribution margin in our institution. Programs considering starting DCD heart transplantation, and those who are currently performing DCD procurement should evaluate their own financial situation.


Assuntos
Transplante de Coração , Obtenção de Tecidos e Órgãos , Humanos , Transplante de Coração/métodos , Doadores de Tecidos , Perfusão/métodos , Morte Encefálica , Morte , Preservação de Órgãos/métodos , Sobrevivência de Enxerto
3.
Clin Transplant ; 37(5): e14942, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36790862

RESUMO

INTRODUCTION: Donation after circulatory death (DCD) heart transplantation has been shown to have comparable outcomes to transplantation using brain death donors (DBDs). This study evaluates the impact of this alternative source of allografts on waitlist mortality and transplant volume. METHODS: We compared waitlist mortality and transplant rates in patients who were registered before (2019 period) and after we adopted DCD heart transplantation (2021 period). RESULTS: We identified 111 patients who were on the waiting list in 2019 and 77 patients who were registered during 2021. Total number of donor organ offers received in 2019 was 385 (178 unique donors) versus 3450 (1145 unique donors) in 2021. More than 40% of all donors in 2021 were DCDs. Waitlist mortality was comparable for patients in 2019 and 2021 (18/100 person-years in 2019 vs. 26/100 person-years in 2021, p = .49). The transplant rate was 67/100 person-years in 2019 versus 207/100 person-years in 2021 (p < .001). After adjusting for acuity status, gender, blood type, and weight, patients listed in 2021 had 2.08 times greater chance of transplantation compared to patients listed in 2019 (HR 2.08, 95% confidence interval [CI] 1.26-3.45, p = .004). CONCLUSIONS: Use of DCD donor hearts significantly increased heart transplant rate in our institution.


Assuntos
Sistema Cardiovascular , Transplante de Coração , Obtenção de Tecidos e Órgãos , Humanos , Listas de Espera , Doadores de Tecidos , Transplante Homólogo , Morte , Estudos Retrospectivos , Sobrevivência de Enxerto
4.
Am J Transplant ; 22(1): 294-298, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34403207

RESUMO

Lung transplantation with lungs procured from donors after circulatory death (DCD) has been established as an alternative technique to traditional donation after brain death (DBD) with comparable outcomes. Recently, in situ thoracoabdominal normothermic regional perfusion (TA-NRP) has emerged as a novel technique employed in the procurement of cardiac allografts after circulatory death. TA-NRP, in contrast to ex situ machine perfusion, has the advantage of allowing in situ assessment of donor organs prior to final acceptance. However, there are some concerns that this technique may adversely impact the quality of lung allografts. Here, we present a case of a successful bilateral sequential lung transplantation in a patient with postinflammatory pulmonary fibrosis due to acute respiratory distress syndrome (ARDS), with lungs procured after normothermic in situ lung perfusion. Apart from the lungs, heart, liver, and kidneys were also successfully transplanted from this donor.


Assuntos
Transplante de Pulmão , Obtenção de Tecidos e Órgãos , Morte , Humanos , Preservação de Órgãos , Perfusão , Doadores de Tecidos
5.
N Engl J Med ; 380(17): 1618-1627, 2019 04 25.
Artigo em Inglês | MEDLINE | ID: mdl-30883052

RESUMO

BACKGROUND: In two interim analyses of this trial, patients with advanced heart failure who were treated with a fully magnetically levitated centrifugal-flow left ventricular assist device were less likely to have pump thrombosis or nondisabling stroke than were patients treated with a mechanical-bearing axial-flow left ventricular assist device. METHODS: We randomly assigned patients with advanced heart failure to receive either the centrifugal-flow pump or the axial-flow pump irrespective of the intended goal of use (bridge to transplantation or destination therapy). The composite primary end point was survival at 2 years free of disabling stroke or reoperation to replace or remove a malfunctioning device. The principal secondary end point was pump replacement at 2 years. RESULTS: This final analysis included 1028 enrolled patients: 516 in the centrifugal-flow pump group and 512 in the axial-flow pump group. In the analysis of the primary end point, 397 patients (76.9%) in the centrifugal-flow pump group, as compared with 332 (64.8%) in the axial-flow pump group, remained alive and free of disabling stroke or reoperation to replace or remove a malfunctioning device at 2 years (relative risk, 0.84; 95% confidence interval [CI], 0.78 to 0.91; P<0.001 for superiority). Pump replacement was less common in the centrifugal-flow pump group than in the axial-flow pump group (12 patients [2.3%] vs. 57 patients [11.3%]; relative risk, 0.21; 95% CI, 0.11 to 0.38; P<0.001). The numbers of events per patient-year for stroke of any severity, major bleeding, and gastrointestinal hemorrhage were lower in the centrifugal-flow pump group than in the axial-flow pump group. CONCLUSIONS: Among patients with advanced heart failure, a fully magnetically levitated centrifugal-flow left ventricular assist device was associated with less frequent need for pump replacement than an axial-flow device and was superior with respect to survival free of disabling stroke or reoperation to replace or remove a malfunctioning device. (Funded by Abbott; MOMENTUM 3 ClinicalTrials.gov number, NCT02224755.).


Assuntos
Insuficiência Cardíaca/terapia , Coração Auxiliar , Desenho de Prótese , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Intervalo Livre de Doença , Feminino , Coração Auxiliar/efeitos adversos , Humanos , Análise de Intenção de Tratamento , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Falha de Prótese , Reoperação/estatística & dados numéricos , Acidente Vascular Cerebral/etiologia
6.
J Card Surg ; 37(10): 3290-3299, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35864745

RESUMO

BACKGROUND: In complex operations surgeon volume may impact outcomes. We sought to understand if individual surgeon volume affects left ventricular assist device (LVAD) outcomes. METHODS: We reviewed primary LVAD implants at an experienced ventricular assist devices (VAD)/transplant center between 2013 and 2019. Cases were dichotomized into a high-volume group (surgeons averaging 11 or more LVAD cases per year), and a low-volume group (10 or less per year). Propensity score matching was performed. Survival to discharge, 1-year survival, and incidence of major adverse events were compared between the low- and high-volume groups. Predictors of survival were identified with multivariate analysis. RESULTS: There were 315 patients who met inclusion criteria-45 in the low-volume group, 270 in the high-volume group. There was no difference in survival to hospital discharge between the low (91.9%) and high (83.3%) volume matched groups (p = .22). Survival at 1-year was also similar (85.4% vs. 80.6%, p = .55). There was no difference in the incidence of major adverse events between the groups. Predictors of mortality in the first year included: age (hazards ratio [HR]: 1.061, p < .001), prior sternotomy (HR: 1.991, p = .01), increasing international normalized ratio (HR: 4.748, p < .001), increasing AST (HR: 1.001, p < .001), increasing bilirubin (HR: 1.081, p = .01), and preoperative mechanical ventilation (HR: 2.662, p = .005). Individual surgeon volume was not an independent predictor of discharge or 1-year survival. CONCLUSION: There was no difference in survival or adverse events between high and low volume surgeons suggesting that, in an experienced multidisciplinary setting, low-volume VAD surgeons can achieve similar outcomes to their high-volume colleagues.


Assuntos
Insuficiência Cardíaca , Transplante de Coração , Coração Auxiliar , Cirurgiões , Insuficiência Cardíaca/cirurgia , Coração Auxiliar/efeitos adversos , Humanos , Modelos de Riscos Proporcionais , Estudos Retrospectivos , Esternotomia , Resultado do Tratamento
7.
Circulation ; 142(21): 2016-2028, 2020 11 24.
Artigo em Inglês | MEDLINE | ID: mdl-33100036

RESUMO

BACKGROUND: Left ventricular assist device (LVAD) unloading and hemodynamic support in patients with advanced chronic heart failure can result in significant improvement in cardiac function allowing LVAD removal; however, the rate of this is generally considered to be low. This prospective multicenter nonrandomized study (RESTAGE-HF [Remission from Stage D Heart Failure]) investigated whether a protocol of optimized LVAD mechanical unloading, combined with standardized specific pharmacological therapy to induce reverse remodeling and regular testing of underlying myocardial function, could produce a higher incidence of LVAD explantation. METHODS: Forty patients with chronic advanced heart failure from nonischemic cardiomyopathy receiving the Heartmate II LVAD were enrolled from 6 centers. LVAD speed was optimized with an aggressive pharmacological regimen, and regular echocardiograms were performed at reduced LVAD speed (6000 rpm, no net flow) to test underlying myocardial function. The primary end point was the proportion of patients with sufficient improvement of myocardial function to reach criteria for explantation within 18 months with sustained remission from heart failure (freedom from transplant/ventricular assist device/death) at 12 months. RESULTS: Before LVAD, age was 35.1±10.8 years, 67.5% were men, heart failure mean duration was 20.8±20.6 months, 95% required inotropic and 20% temporary mechanical support, left ventricular ejection fraction was 14.5±5.3%, end-diastolic diameter was 7.33±0.89 cm, end-systolic diameter was 6.74±0.88 cm, pulmonary artery saturations were 46.7±9.2%, and pulmonary capillary wedge pressure was 26.2±7.6 mm Hg. Four enrolled patients did not undergo the protocol because of medical complications unrelated to the study procedures. Overall, 40% of all enrolled (16/40) patients achieved the primary end point, P<0.0001, with 50% (18/36) of patients receiving the protocol being explanted within 18 months (pre-explant left ventricular ejection fraction, 57±8%; end-diastolic diameter, 4.81±0.58 cm; end-systolic diameter, 3.53±0.51 cm; pulmonary capillary wedge pressure, 8.1±3.1 mm Hg; pulmonary artery saturations 63.6±6.8% at 6000 rpm). Overall, 19 patients were explanted (19/36, 52.3% of those receiving the protocol). The 15 ongoing explanted patients are now 2.26±0.97 years after explant. After explantation survival free from LVAD or transplantation was 90% at 1-year and 77% at 2 and 3 years. CONCLUSIONS: In this multicenter prospective study, this strategy of LVAD support combined with a standardized pharmacological and cardiac function monitoring protocol resulted in a high rate of LVAD explantation and was feasible and reproducible with explants occurring in all 6 participating sites. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT01774656.


Assuntos
Remoção de Dispositivo , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/cirurgia , Coração Auxiliar , Recuperação de Função Fisiológica/fisiologia , Função Ventricular Esquerda/fisiologia , Adulto , Remoção de Dispositivo/tendências , Feminino , Insuficiência Cardíaca/fisiopatologia , Coração Auxiliar/tendências , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Indução de Remissão/métodos
8.
Clin Transplant ; 34(11): e14060, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32772397

RESUMO

Although temporary mechanical circulatory support (tMCS) for hemodynamic failure following heart transplantation is associated with increased early morbidity and mortality, the impact of etiology of graft dysfunction and long-term clinical implications are less well known. The objective of our study was to evaluate outcomes in patients who required venoarterial extracorporeal membrane oxygenation (VA ECMO) or temporary right ventricular assist device (RVAD) support for either primary or secondary early graft dysfunction. Hospital mortality in 27 patients who required tMCS following heart transplantation at our institution between 2007 and 2017 was 56%, 30% in patients with right ventricular dysfunction secondary to increased afterload, 60% in patients with primary graft dysfunction, and 100% in patients with graft failure secondary to coagulopathy with intraoperative bleeding or overwhelming sepsis. Conditional 1-year and 5-year survival was comparable between patients with, and without, the need for post-transplantation support with tMCS (98% and 89%; 92% and 65% at 1 and 5 years, P = .21). Etiology of early graft failure plays an important part in determining the short-term post-heart transplantation outcome. Although complications associated with tMCS use, such as renal dysfunction and infection, extend beyond index transplant hospitalization, long-term conditional survival is not compromised.


Assuntos
Oxigenação por Membrana Extracorpórea , Insuficiência Cardíaca , Transplante de Coração , Coração Auxiliar , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/cirurgia , Transplante de Coração/efeitos adversos , Coração Auxiliar/efeitos adversos , Humanos , Estudos Retrospectivos , Resultado do Tratamento
9.
J Card Fail ; 25(4): 249-256, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30685400

RESUMO

BACKGROUND: The effect of elevated heart rate (HR) on outcomes after heart transplantation (HT) has not been well established. The aim of this study was to assess predictors of elevated HR following HT and its impact on outcomes. METHODS AND RESULTS: We retrospectively evaluated 394 patients who underwent HT at 2 academic medical centers from 2005 to 2016. Patients were divided into 2 groups based on HR 1 year after HT: HR ≥95 beats/min (n = 162; 41%) and HR <95 beats/min (n = 232; 59%). Median follow-up time was 6.6 (interquartile range [IQR] 2.2-7.5) years. HR ≥95 beats/min 1 year after HT was associated with younger donor age, whereas HR <95 beats/min was associated with heavy donor alcohol use and African-American recipient race. Left ventricular (LV) end-diastolic dimension, mass, and ejection fraction were lower and E/E' higher in the HR ≥95 group at the time of the last follow up. HR ≥95 beats/min at 1 year after HT was independently associated with the development of cardiac allograft vasculopathy and increased mortality. CONCLUSIONS: HR ≥95 beats/min 1 year after HT is associated with a reduction in LV size and function, increased incidence of cardiac allograft vasculopathy, and reduced survival. Studies investigating the effect of medical HR reduction on post-HT outcomes are warranted.


Assuntos
Rejeição de Enxerto/epidemiologia , Insuficiência Cardíaca/cirurgia , Frequência Cardíaca/fisiologia , Transplante de Coração/efeitos adversos , Medição de Risco/métodos , Adulto , Aloenxertos , Ecocardiografia , Feminino , Seguimentos , Rejeição de Enxerto/diagnóstico , Rejeição de Enxerto/fisiopatologia , Insuficiência Cardíaca/mortalidade , Transplante de Coração/mortalidade , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Taxa de Sobrevida/tendências , Estados Unidos/epidemiologia
10.
Clin Transplant ; 33(2): e13461, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30536743

RESUMO

BACKGROUND: Current guidelines recommend against the use of hearts from donors that abuse alcohol. We explored the effect of donor alcohol abuse (AA) on cardiac allograft function and outcomes in heart transplant (HTx) recipients. METHODS: Overall, 370 HTx recipients were divided into two groups: (a) the alcoholic donor group (AD, n = 58) and (b) the non-alcoholic donor group (NAD, n = 312). RESULTS: Recipients in the AD group had a slower heart rate (86 ± 13 vs 93 ± 13, P = 0.004) and an increased incidence of early atrial fibrillation (AF) (30% vs 11%, P = 0.003). Echocardiographic left ventricular mass was higher among alcoholic donors (171.7 ± 66.7 vs 151.6 ± 54.7, P = 0.02). This difference remained present 1 year following HTx (185 ± 43 vs 166 ± 42, P = 0.007). E/E' was higher in the AD group (9.5 ± 3.9 vs 8.4 ± 2.9, P = 0.04) and a larger number of AD recipients had a ventilatory equivalent for VCO2  > 34 (50% vs 31%, P = 0.04) on cardiopulmonary exercise test. There was no significant difference in rejection, cardiac allograft vasculopathy (CAV), or survival between the groups. CONCLUSIONS: Our data suggest that donor AA does not impact rejection, CAV, or intermediate-term survival, but may cause increased incidence of post-HTx AF and impaired cardiac allograft diastolic function.


Assuntos
Alcoolismo/complicações , Cardiopatias/mortalidade , Transplante de Coração/mortalidade , Medição de Risco/métodos , Doadores de Tecidos/provisão & distribuição , Causas de Morte , Feminino , Seguimentos , Cardiopatias/epidemiologia , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Retrospectivos , Fatores de Risco , Taxa de Sobrevida
11.
J Card Surg ; 34(11): 1228-1234, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31478259

RESUMO

BACKGROUND: Several patient-related characteristics have been associated with inferior outcomes following durable left ventricular assist device (LVAD) implantation in patients transitioned from venoarterial extracorporeal membrane oxygenation (VA ECMO). The impact of LVAD pump type used is less well-known. METHODS: We compared outcomes between patents who received axial and centrifugal flow LVADs following stabilization with VA ECMO. RESULTS: From January 2011 to December 2018, we implanted 28 LVADs in patients transitioned from VA ECMO. This included 17 axial flow devices (HeartMate II LVAD, Abbott Laboratories, Chicago, IL) and 11 centrifugal flow pumps (eight HeartWare HVADs; Medtronic, Minneapolis, MN and three HeartMate 3 LVAS pumps; Abbott Laboratories, Chicago, IL). There was no difference in hospital mortality (23.5% vs 18.2%, P = .74) or 1-year survival (P = .31) between the devices. There were no differences in adverse event rates between the two pump types, apart from a higher rate of gastrointestinal bleeding in patients who received centrifugal flow pumps (1.44 events per 100 patient-months vs 14.67 events per 100 patient-months, P = .010). Preimplantation levels of alanine aminotransferase (hazard ratio [HR], 1.001; 95% confidence interval [CI], 1.000 to 1.002; P = .004) and elevated serum creatinine level (HR, 3.480; 95% CI, 1.121-10.807; P = .031) emerged as significant predictors of decreased 1-year survival. CONCLUSIONS: Preimplantation optimization of end-organ function is the single most important determinant of successful post-LVAD survival in patients transitioned from extracorporeal life support. There is no association of pump type with LVAD outcomes up to 1-year post implantation.


Assuntos
Coração Auxiliar , Oxigenação por Membrana Extracorpórea , Humanos
13.
Clin Transplant ; 31(5)2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-28251691

RESUMO

BACKGROUND: Sinus tachycardia often presents in heart transplantation (HTx) recipients, but data on its effect on exercise performance are limited. METHODS: Based on mean heart rate (HR) value 3 months after HTx, 181 patients transplanted from 2006 to 2015 at University of Nebraska Medical Center were divided into two groups: (i) HR<95 beats/min (bpm, n=93); and (ii) HR≥95 bpm (n=88). Cardiopulmonary exercise testing (CPET) was performed 1 year after HTx. RESULTS: Mean HR at 3 months post-HTx was 94±11 bpm and did not change significantly at 1 year post-HTx (96±11 bpm, P=.13). HR≥95 bpm at 3 months was associated with younger donor age (OR 1.1; CI 1.0-1.1, P=.02), female donors (OR -2.4; CI 1.16-5.24 P=.02), and lack of donors' heavy alcohol use (OR -0.43; CI 0.17-0.61; P=.04). HR≥95 bpm at 3 months post-HTx was independently associated with decreased exercise capacity in metabolic equivalent (P=.008), reduced peak VO2 (P=.006), and percent of predicted peak VO2 (P=.002) during CPET. CONCLUSIONS: HR≥95 at 3 months following HTx is associated with reduced exercise tolerance in stable HTx recipients. Medical HR reduction after HTx could improve exercise performance after HTx and merits further investigation.


Assuntos
Tolerância ao Exercício/fisiologia , Transplante de Coração/efeitos adversos , Taquicardia Sinusal/etiologia , Adulto , Feminino , Seguimentos , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Consumo de Oxigênio , Prognóstico , Fatores de Tempo
14.
Clin Transplant ; 31(8)2017 08.
Artigo em Inglês | MEDLINE | ID: mdl-28477381

RESUMO

BACKGROUND: Sinus tachycardia (ST) is common after heart transplantation (HTx). The aim of the study was to evaluate the effect of diltiazem treatment during the first year after HTx on heart rate (HR), cardiac allograft function, and exercise capacity. METHODS: From the total cohort, 25 HTx recipients started diltiazem treatment 4±2 weeks after HTx and continued it for at least 1 year (diltiazem group). Each study case was matched to a control. All patients underwent hemodynamic assessment and cardiopulmonary exercise test (CPET) at 1 year after HTx. RESULTS: HR decreased in the diltiazem group from 99±11 bpm to 94±7 bpm (P=.03) and did not change in the controls (98±11 bpm vs 100±13 bpm, P=.14). The difference between the groups at 1 year after HTx was significant (P=.04). In the diltiazem group left ventricular (LV), stroke volume and ejection fraction increased (48±16 vs 55±17 mL, P=.02, and 60%±10% vs 62%±12% P=.03, respectively) but did not differ from controls. E/E' decreased (10.7±2.7 vs 7.3±1.9, P=.003) while cardiac index was higher (3.5±0.8 vs 3.1±0.5; P=.05) in the diltiazem group at 1-year follow-up. The absolute peak VO2 (21±4 vs 18±6 mL/kg/min; P=.05) and normalized peak VO2 (73%±17% vs 58%±14%; P=.004) were significantly higher in the diltiazem group. CONCLUSIONS: This study showed that diltiazem treatment reduces ST, may improve cardiac allograft function and exercise tolerance during the first year after HTx.


Assuntos
Fármacos Cardiovasculares/farmacologia , Diltiazem/farmacologia , Tolerância ao Exercício/efeitos dos fármacos , Transplante de Coração , Complicações Pós-Operatórias/tratamento farmacológico , Taquicardia Sinusal/tratamento farmacológico , Adulto , Idoso , Fármacos Cardiovasculares/uso terapêutico , Diltiazem/uso terapêutico , Esquema de Medicação , Teste de Esforço , Feminino , Seguimentos , Frequência Cardíaca/efeitos dos fármacos , Humanos , Masculino , Pessoa de Meia-Idade , Qualidade de Vida , Estudos Retrospectivos , Volume Sistólico/efeitos dos fármacos , Taquicardia Sinusal/etiologia , Resultado do Tratamento
15.
J Transl Med ; 14(1): 327, 2016 11 25.
Artigo em Inglês | MEDLINE | ID: mdl-27884156

RESUMO

BACKGROUND: Myocardial recovery with left ventricular assist device (LVAD) therapy is highly variable and difficult to predict. Next generation ribonucleic acid (RNA) sequencing is an innovative, rapid, and quantitative approach to gene expression profiling in small amounts of tissue. Our primary goal was to identify baseline transcriptional profiles in non-ischemic cardiomyopathies that predict myocardial recovery in response to LVAD therapy. We also sought to verify transcriptional differences between failing and non-failing human hearts. METHODS: RNA was isolated from failing (n = 16) and non-failing (n = 8) human hearts. RNA from each patient was reverse transcribed and quantitatively sequenced on the personal genome machine (PGM) sequencer (Ion torrent) for 95 heart failure candidate genes. Coverage analysis as well as mapping the reads and alignment was done using the Ion Torrent Browser Suite™. Differential expression analyses were conducted by empirical analysis of digital gene expression data in R (edgeR) to identify differential expressed genes between failing and non-failing groups, and between responder and non-responder groups respectively. Targeted cardiac gene messenger RNA (mRNA) expression was analyzed in proportion to the total number of reads. Gene expression profiles from the PGM sequencer were validated by performing RNA sequencing (RNAseq) with the Illumina Hiseq2500 sequencing system. RESULTS: The failing sample population was 75% male with an average age of 50 and a left ventricular ejection fraction (LVEF) of 16%. Myosin light chain kinase (MYLK) and interleukin (IL)-6 genes expression were significantly higher in LVAD responders compared to non-responders. Thirty-six cardiac genes were expressed differentially between failing and non-failing hearts (23 decreased, 13 elevated). MYLK, Beta-1 adrenergic receptor (ADRB1) and myosin heavy chain (MYH)-6 expression were among those significantly decreased in failing hearts compared to non-failing hearts. Natriuretic peptide B (NPPB) and IL-6 were significantly elevated. Targeted gene expression profiles obtained from the Ion torrent PGM sequencer were consistent with those obtained from Illumina HiSeq2500 sequencing system. CONCLUSIONS: Heart failure is associated with a network of transcriptional changes involving contractile proteins, metabolism, adrenergic receptors, protein phosphorylation, and signaling factors. Myocardial MYLK and IL-6 expression are positively correlated with ejection fraction (EF) response to LVAD placement. Targeted RNA sequencing of myocardial gene expression can be utilized to predict responders to LVAD therapy and to better characterize transcriptional changes in human heart failure.


Assuntos
Perfilação da Expressão Gênica , Insuficiência Cardíaca/genética , Miocárdio/metabolismo , Análise de Sequência de RNA/métodos , Regulação para Baixo/genética , Feminino , Coração Auxiliar , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Transdução de Sinais/genética , Resultado do Tratamento , Regulação para Cima/genética
16.
Semin Dial ; 28(6): 670-5, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26133515

RESUMO

The use of ventricular assist devices (VAD) and total artificial heart (TAH) is increasing rapidly, and a large proportion of these device recipients already have or will develop severe renal dysfunction at the time of device implantation. As a consequence, nephrologists are becoming more and more involved in the care of this challenging population. As nephrologists take upon themselves many aspects of dialysis vascular access care, they need to be familiar with the special circumstances of performing hemodialysis catheter procedures in these patients. This review describes the important characteristics of these devices that have serious implications for the technique of placing or replacing dialysis catheters. These implications apply for both tunneled and nontunneled dialysis catheters and so concern all nephrologists, not only the interventionalists. We describe the important anatomical factors, anticoagulation management, device management, vascular access management and technical considerations of placing or replacing tunneled and nontunneled hemodialysis catheters from the perspective of a nephrologist establishing and maintaining lifesaving dialysis vascular access. Without a good understanding of these devices, serious consequences such as VAD rotor damage or blockage, or artificial heart valve blockage or damage can occur. These artificial devices are lifesaving, and any such complication is unacceptable. This review describes steps to minimize the risks.


Assuntos
Derivação Arteriovenosa Cirúrgica/métodos , Cateteres de Demora , Competência Clínica , Insuficiência Cardíaca/terapia , Coração Auxiliar , Falência Renal Crônica/terapia , Diálise Renal/métodos , Cateterismo Venoso Central/métodos , Insuficiência Cardíaca/complicações , Humanos , Falência Renal Crônica/complicações , Nefrologia
17.
Artigo em Inglês | MEDLINE | ID: mdl-38367698

RESUMO

OBJECTIVES: The HeartMate 3 (Abbott) left ventricular assist device provides substantial improvement in long-term morbidity and mortality in patients with advanced heart failure. The Implantation of the HeartMate 3 in Subjects With Heart Failure Using Surgical Techniques Other Than Full Median Sternotomy study compares thoracotomy-based implantation clinical outcomes with standard median sternotomy. METHODS: We conducted a prospective, multicenter, single-arm study in patients eligible for HeartMate 3 implantation with thoracotomy-based surgical technique (bilateral thoracotomy or partial upper sternotomy with left thoracotomy). The composite primary end point was survival free of disabling stroke (modified Rankin score >3), or reoperation to remove or replace a malfunctioning device, or conversion to median sternotomy at 6-months postimplant (elective transplants were treated as a success). The primary end point (noninferiority, -15% margin) was assessed with >90% power compared with a propensity score-matched cohort (ratio 1:2) derived from the Multi-Center Study of MagLev Technology in Patients Undergoing Mechanical Circulatory Support Therapy With HeartMate 3 continued access protocol. RESULTS: The study enrolled 102 patients between December 2020 and July 2022 in the thoracotomy-based arm at 23 North American centers. Follow-up concluded in December 2022. In the Implantation of the HeartMate 3 in Subjects With Heart Failure Using Surgical Techniques Other Than Full Median Sternotomy study group, noninferiority criteria was met (absolute between-group difference, -1.2%; Farrington Manning lower 1-sided 95% CI, -9.3%; P < .0025) and event-free survival was not different (85.0% vs 86.2%; hazard ratio, 1.01; 95% CI, 0.58-2.10). Length of stay with thoracotomy-based implant was longer (median, 20 vs 17 days; P = .03). No differences were observed for blood product utilization, adverse events (including right heart failure), functional status, and quality of life between cohorts. CONCLUSIONS: Thoracotomy-based implantation of the HeartMate 3 left ventricular assist device is noninferior to implantation via standard full sternotomy. This study supports thoracotomy-based implantation as an additional standard for surgical implantation of the HeartMate 3 left ventricular assist device.

18.
Transplant Proc ; 55(9): 1997-2002, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37739830

RESUMO

BACKGROUND: Donation after circulatory death (DCD) heart transplantation is being increasingly adopted by transplant centers. The optimal method of DCD heart preservation during transport after in situ thoracoabdominal normothermic regional perfusion (TA-NRP) is not known. METHODS: We evaluated our experience with the Paragonix SherpaPak Cardiac Transport System (SCTS) for the transport of DCD cardiac allografts after TA-NRP recovery between January 2021 and December 2022. We collected and evaluated donor characteristics, allograft ischemic intervals, and recipient baseline demographic and clinical variables, and short-term outcomes. RESULTS: Twelve recipients received DCD grafts recovered with TA-NRP and transported in SCTS during the study period. The median age of 10 male and 2 female donors was 32 years (min 15, max 38). The median duration of functional warm ischemia was 12 minutes (min 8, max 22). Hearts were preserved in SCTS for a median of 158 minutes (min 37, max 224). Median recipient age was 61 years (min 28, max 70). Ten recipients (83%) survived to hospital discharge, with one death attributable to graft dysfunction (8%). The median vasoactive-inotropic (VIS) score at 72 hours post-transplantation of the entire cohort was 6 (min 0, max 15). The median length of intensive care unit stay in hospital survivors was 5 days (min 3, max 17) days and hospital stay 17 days (min 9, max 37). CONCLUSIONS: The Paragonix SCTS provides efficacious preservation of DCD grafts for ≥3.5 hours. Organs transported with this device showed satisfactory post-transplantation function.


Assuntos
Transplante de Coração , Obtenção de Tecidos e Órgãos , Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Doadores de Tecidos , Transplante de Coração/efeitos adversos , Coração , Perfusão/métodos , Isquemia Quente , Preservação de Órgãos/métodos , Morte , Sobrevivência de Enxerto
19.
JTCVS Tech ; 15: 136-143, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36276687

RESUMO

Objectives: To determine whether hearts reanimated with normothermic regional perfusion (NRP) have clinically detectable changes in function using echocardiography comparing the prearrest and post-NRP imaging. As heart transplantation from donation after circulatory death (DCD) continues to increase, preliminary results suggest outcomes comparable with donation after brain death. It is unknown whether the obligatory period of warm ischemia experienced during DCD withdrawal process causes immediate changes in cardiac allograft function following in situ reanimation. Methods: We retrospectively reviewed and compared predonation with postreanimation echocardiographic findings in all DCD donors at our institution from January to October 2021. All DCD donor organs were reanimated with in situ thoracoabdominal NRP after circulatory death. Echocardiographic assessment included (1) 2-dimensional and speckle-tracking measures of chamber size and function; (2) ejection fraction; (3) fractional area change; and (4) global longitudinal strain. Results: Altogether, 4 DCD heart donations were performed during the study period. Basic demographics and withdrawal ischemic time periods are reported. There were no changes in left ventricular ejection fraction and right ventricular fractional area change when comparing the predonation and the postreanimation echocardiogram. There was a minimal, nonstatistically significant decrease in left ventricular global longitudinal strain and right ventricular free-wall systolic strain in 3 of the 4 donors following reanimation. Conclusions: DCD cardiac allografts reanimated with NRP demonstrated no change in echocardiographic parameters used for a standard predonation donor heart evaluation. Findings suggest cardiac function of DCD allografts reanimated with thoracoabdominal NRP is not adversely impacted by limited period of warm ischemia following circulatory arrest.

20.
Ann Thorac Surg ; 113(6): e473-e476, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-34634242

RESUMO

Donation after circulatory death is emerging as an alternative pathway to donation after brain death to expand the cardiac organ donor pool. We describe the surgical technique and circuit configuration for in-situ organ reperfusion with thoracoabdominal normothermic regional perfusion using portable venoarterial extracorporeal membrane oxygenation.


Assuntos
Transplante de Coração , Obtenção de Tecidos e Órgãos , Morte , Humanos , Preservação de Órgãos/métodos , Perfusão/métodos , Doadores de Tecidos
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa