Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 60
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Vasc Res ; 61(3): 142-150, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38631294

RESUMO

INTRODUCTION: During the first COVID-19 outbreak in 2020 in the Netherlands, the incidence of pulmonary embolism (PE) appeared to be high in COVID-19 patients admitted to the intensive care unit (ICU). This study was performed to evaluate the incidence of PE during hospital stay in COVID-19 patients not admitted to the ICU. METHODS: Data were retrospectively collected from 8 hospitals in the Netherlands. Patients admitted between February 27, 2020, and July 31, 2020, were included. Data extracted comprised clinical characteristics, medication use, first onset of COVID-19-related symptoms, admission date due to COVID-19, and date of PE diagnosis. Only polymerase chain reaction (PCR)-positive patients were included. All PEs were diagnosed with computed tomography pulmonary angiography (CTPA). RESULTS: Data from 1,852 patients who were admitted to the hospital ward were collected. Forty patients (2.2%) were diagnosed with PE within 28 days following hospital admission. The median time to PE since admission was 4.5 days (IQR 0.0-9.0). In all 40 patients, PE was diagnosed within the first 2 weeks after hospital admission and for 22 (55%) patients within 2 weeks after onset of symptoms. Patient characteristics, pre-existing comorbidities, anticoagulant use, and laboratory parameters at admission were not related to the development of PE. CONCLUSION: In this retrospective multicenter cohort study of 1,852 COVID-19 patients only admitted to the non-ICU wards, the incidence of CTPA-confirmed PE was 2.2% during the first 4 weeks after onset of symptoms and occurred exclusively within 2 weeks after hospital admission.


Assuntos
COVID-19 , Embolia Pulmonar , Humanos , COVID-19/epidemiologia , COVID-19/diagnóstico , COVID-19/complicações , Embolia Pulmonar/epidemiologia , Embolia Pulmonar/diagnóstico por imagem , Embolia Pulmonar/diagnóstico , Países Baixos/epidemiologia , Estudos Retrospectivos , Masculino , Feminino , Idoso , Pessoa de Meia-Idade , Incidência , Fatores de Risco , Idoso de 80 Anos ou mais , Hospitalização , Fatores de Tempo , SARS-CoV-2 , Angiografia por Tomografia Computadorizada
2.
Diabet Med ; 39(4): e14725, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34657300

RESUMO

AIMS: A diabetic foot ulcer (DFU) is a severe condition associated with morbidity and mortality. Population-based studies are rare and limited by access to reliable data. Without this data, efforts in primary prevention cannot be evaluated. Therefore, we examined the incidence and changes over time for the first DFU in people with diabetes. We also examined hospitalization and all-cause mortality and their changes over time. METHODS: From the UK primary care CPRD GOLD database (2007-2017), we identified 129,624 people with diabetes by a prescription for insulin or a non-insulin anti-diabetic drug. DFUs were identified using Read codes and expressed as incidence rates (IRs). Changes over time were described using Poisson and logistic regression and expressed as incidence rate ratios (IRRs) and odds ratios (ORs) respectively. RESULTS: The mean IR of first registered DFUs was 2.5 [95% CI: 2.1-2.9] per 1000 person-years for people with type 2 diabetes and 1.6 [1.3-1.9] per 1000 person-years for people with type 1. The IRs declined for people with type 2 diabetes (IRR per year: 0.97 [0.96-0.99]), while no changes were observed for people with type 1 diabetes (IRR per year: 0.96 [0.89-1.04]). Average hospitalization and 1-year mortality risk for people with type 2 diabetes were 8.2% [SD: 4.7] and 11.7% [SD: 2.2] respectively. Both declined over time (OR: 0.89 [0.84, 0.94] and 0.94 [0.89, 0.99]). CONCLUSION: The decline in all IRs, hospitalizations and mortality in people with type 2 diabetes suggests that prevention and care of the first DFU has improved for this group in primary care in the UK.


Assuntos
Diabetes Mellitus Tipo 2 , Pé Diabético , Diabetes Mellitus Tipo 2/complicações , Diabetes Mellitus Tipo 2/epidemiologia , Pé Diabético/complicações , Pé Diabético/epidemiologia , Pé Diabético/terapia , Hospitalização , Humanos , Incidência , Fatores de Risco
3.
Calcif Tissue Int ; 108(3): 314-323, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33452889

RESUMO

Obtaining high-resolution scans of bones and joints for clinical applications is challenging. HR-pQCT is considered the best technology to acquire high-resolution images of the peripheral skeleton in vivo, but a breakthrough for widespread clinical applications is still lacking. Recently, we showed on trapezia that CBCT is a promising alternative providing a larger FOV at a shorter scanning time. The goals of this study were to evaluate the accuracy of CBCT in quantifying trabecular bone microstructural and predicted mechanical parameters of the distal radius, the most often investigated skeletal site with HR-pQCT, and to compare it with HR-pQCT. Nineteen radii were scanned with four scanners: (1) HR-pQCT (XtremeCT, Scanco Medical AG, @ (voxel size) 82 µm), (2) HR-pQCT (XtremeCT-II, Scanco, @60.7 µm), (3) CBCT (NewTom 5G, Cefla, @75 µm) reconstructed and segmented using in-house developed software and (4) microCT (VivaCT40, Scanco, @19 µm-gold standard). The following parameters were evaluated: predicted stiffness, strength, bone volume fraction (BV/TV) and trabecular thickness (Tb.Th), separation (Tb.Sp) and number (Tb.N). The overall accuracy of CBCT with in-house optimized algorithms in quantifying bone microstructural parameters was comparable (R2 = 0.79) to XtremeCT (R2 = 0.76) and slightly worse than XtremeCT-II (R2 = 0.86) which were both processed with the standard manufacturer's technique. CBCT had higher accuracy for BV/TV and Tb.Th but lower for Tb.Sp and Tb.N compared to XtremeCT. Regarding the mechanical parameters, all scanners had high accuracy (R2 [Formula: see text] 0.96). While HR-pQCT is optimized for research, the fast scanning time and good accuracy renders CBCT a promising technique for high-resolution clinical scanning.


Assuntos
Densidade Óssea , Osso e Ossos/diagnóstico por imagem , Tomografia Computadorizada de Feixe Cônico , Rádio (Anatomia) , Algoritmos , Humanos , Rádio (Anatomia)/diagnóstico por imagem , Microtomografia por Raio-X
4.
Calcif Tissue Int ; 107(4): 327-334, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32725291

RESUMO

Celiac disease (CD) is a known risk factor for osteoporosis and fractures. The prevalence of CD in patients with a recent fracture is unknown. We therefore systematically screened patients at a fracture liaison service (FLS) to study the prevalence of CD. Patients with a recent fracture aged ≥ 50 years were invited to VieCuri Medical Center's FLS. In FLS attendees, bone mineral density (BMD) and laboratory evaluation for metabolic bone disorders and serological screening for CD was systematically evaluated. If serologic testing for CD was positive, duodenal biopsies were performed to confirm the diagnosis CD. Data were collected in 1042 consecutive FLS attendees. Median age was 66 years (Interquartile range (IQR) 15), 27.6% had a major and 6.9% a hip fracture, 26.4% had osteoporosis and 50.8% osteopenia. Prevalent vertebral fractures were found in 29.1%. CD was already diagnosed in two patients (0.19%), one still had a positive serology. Three other patients (0.29%) had a positive serology for CD (one with gastro-intestinal complaints). In two of them, CD was confirmed by duodenal histology (0.19%) and one refused further evaluation. The prevalence of biopsy-proven CD was therefore 0.38% (4/1042) of which 0.19% (2/1042) was newly diagnosed. The prevalence of CD in patients with a recent fracture at the FLS was 0.38% and within the range of reported prevalences in the Western-European population (0.33-1.5%). Newly diagnosed CD was only found in 0.19%. Therefore, standard screening for CD in FLS patients is not recommended.


Assuntos
Doença Celíaca , Osteoporose , Fraturas por Osteoporose , Idoso , Idoso de 80 Anos ou mais , Doença Celíaca/epidemiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Osteoporose/epidemiologia , Fraturas por Osteoporose/epidemiologia , Prevalência
5.
Aging Clin Exp Res ; 31(8): 1105-1111, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30311093

RESUMO

BACKGROUND: Several guidelines recommend a bone and fall-related osteoporosis risk assessment in all patients with fracture and age > 50 years. In practice, however, there is no consensus whether screening > 85 years is useful. AIM: To evaluate the subsequent fracture risk in all patient > 85 years, comparing the two populations of Fracture Liaison Service (FLS) attenders and non-attenders. METHODS: All patients > 85 years that presented at the FLS with a non-vertebral fracture were included in the study during a 5-year period (September 2004 and December 2009). Excluded were pathologic fractures, death < 30 days, or patients on osteoporosis treatment. in patients that attended the FLS, assessment of bone mineral density and fall-risk factors were screened. In both the attenders and non-attenders groups, mortality and subsequent fracture rates were scored during a follow-up of 2 years. RESULTS: 282 patients fulfilled inclusion criteria for screening, of which 160 (57%) patients did not attend the FLS. 122 patients were screened for osteoporosis and fall-related risk of whom 72 were diagnosed with osteoporosis. Subsequent fracture risk in both groups was 19%. Medical treatment was started in 51 patients, of which 15 patients developed a subsequent fracture. Cox-regression analysis indicated a significantly lower mortality rate, but not a diminished subsequent fracture rate in the FLS screened population compared to the non-attenders. CONCLUSION: The advantage of a FLS in reducing subsequent fracture risk in patients > 85 years seems to be limited. In practice a large proportion of these patients are not screened.


Assuntos
Fraturas por Osteoporose/prevenção & controle , Acidentes por Quedas , Idoso de 80 Anos ou mais , Densidade Óssea , Feminino , Humanos , Masculino , Programas de Rastreamento , Osteoporose/diagnóstico , Fraturas por Osteoporose/epidemiologia , Fatores de Risco
6.
Calcif Tissue Int ; 103(3): 252-265, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29594493

RESUMO

Most HR-pQCT studies examining cortical bone use an automatically generated endocortical contour (AUTO), which is manually corrected if it visually deviates from the apparent endocortical margin (semi-automatic method, S-AUTO). This technique may be prone to operator-related variability and is time consuming. We examined whether the AUTO instead of the S-AUTO method can be used for cortical bone analysis. Fifty scans of the distal radius and tibia from participants of The Maastricht Study were evaluated with AUTO, and subsequently with S-AUTO by three independent operators. AUTO cortical bone parameters were compared to the average parameters obtained by the three operators (S-AUTOmean). All differences in mean cortical bone parameters between AUTO and S-AUTOmean were < 5%, except for lower AUTO cortical porosity of the radius (- 16%) and tibia (- 6%), and cortical pore volume (Ct.Po.V) of the radius (- 7%). The ICC of S-AUTOmean and AUTO was > 0.90 for all parameters, except for cortical pore diameter of the radius (0.79) and tibia (0.74) and Ct.Po.V of the tibia (0.89), without systematic errors on the Bland-Altman plots. The precision errors (RMS-CV%) of the radius parameters between S-AUTOmean and AUTO were comparable to those between the individual operators, whereas the tibia RMS-CV% between S-AUTOmean and AUTO were higher than those of the individual operators. Comparison of the three operators revealed clear inter-operator variability. This study suggests that the AUTO method can be used for cortical bone analysis in a cross-sectional study, but that the absolute values-particularly of the porosity-related parameters-will be lower.


Assuntos
Osso Cortical/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
7.
Calcif Tissue Int ; 101(3): 248-258, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28536889

RESUMO

The aetiology of fractures in patients aged 50 years and older is multifactorial, and includes bone- and fall-related risks. The Fracture Liaison Service (FLS) is recommended to identify patients with a recent fracture and to evaluate their subsequent fracture risk, in order to take measures to decrease the risk of subsequent fractures in patients with a high risk phenotype. A literature survey was conducted to describe components of the bone- and fall-related phenotype of patients attending the FLS. Components of the patient phenotype at the FLS have been reported in 33 studies. Patient selection varied widely in terms of patient identification, selection, and FLS attendance. Consequently, there was a high variability in FLS patient characteristics, such as mean age (64-80 years), proportion of men (13-30%), and fracture locations (2-51% hip, <1-41% vertebral, and 49-95% non-hip, non-vertebral fractures). The studies also varied in the risk evaluation performed. When reported, there was a highly variability in the percentage of patients with osteoporosis (12-54%), prevalent vertebral fractures (20-57%), newly diagnosed contributors to secondary osteoporosis and metabolic bone disorders (3-70%), and fall-related risk factors (60-84%). In FLS literature, we found a high variability in patient selection and risk evaluation, resulting in a highly variable phenotype. In order to specify the bone- and fall related phenotypes at the FLS, systematic studies on the presence and combinations of these risks are needed.


Assuntos
Fraturas Ósseas , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fenótipo , Fatores de Risco
8.
Diabetes Obes Metab ; 19(3): 421-428, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-27943565

RESUMO

AIMS: To investigate the association between long-term dipeptidyl peptidase-4 (DPP-4) inhibitor use and risk of fracture among people with type 2 diabetes mellitus (T2DM). METHODS: A retrospective population-based cohort study, using data from the Clinical Practice Research Datalink database (2007-2015), was conducted. All those (N = 328 254) with at least one prescription for a non-insulin antidiabetic drug (NIAD), aged ≥18 years at the time of data collection, were included. Cox proportional hazards models were used to estimate the hazard ratios of any fracture, osteoporotic fracture and hip fracture in DPP-4 inhibitor users compared with those using other NIADs. Analyses were stratified by continuous duration of DPP-4 inhibitor use. Time-dependent adjustments were made for age, sex, lifestyle, comorbidity and concomitant drug use. RESULTS: Current use of DPP-4 inhibitors was not associated with risk of any fracture (adjusted hazard ratio [HR] 0.99 [95% confidence interval {CI} 0.93-1.06]) as compared with current other NIAD use. Current use of DPP-4 inhibitors was also not associated with risk of osteoporotic or hip fracture. After stratification by continuous duration of DPP-4 inhibitor use the highest category was not associated with any (>4.0-8.5 years of use, adjusted HR 0.99 [95% CI 0.70-1.41]), osteoporotic (>3.0-8.5 years of use, adjusted HR 0.75 [95% CI 0.52-1.09]) or hip (>2.0-8.5 years of use; adjusted HR 1.24 [95% CI 0.85-1.79]) fracture. CONCLUSION: Continuous long-term DPP-4 inhibitor use (defined as >4.0-8.5 years of DPP-4 inhibitor use for any fracture, >3.0-8.5 years for osteoporotic fracture and >2.0-8.5 years for hip fracture was not associated with risk of any, osteoporotic or hip fracture. These findings may be of value for clinical decisions regarding treatment of patients with T2DM, especially those at high risk of fracture.


Assuntos
Diabetes Mellitus Tipo 2/tratamento farmacológico , Inibidores da Dipeptidil Peptidase IV/uso terapêutico , Fraturas Ósseas/epidemiologia , Fraturas do Quadril/epidemiologia , Hipoglicemiantes/uso terapêutico , Fraturas por Osteoporose/epidemiologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Bases de Dados Factuais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Modelos de Riscos Proporcionais , Estudos Retrospectivos , Fatores de Risco , Adulto Jovem
9.
Br J Clin Pharmacol ; 83(4): 923-926, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-27780288

RESUMO

The aim of the present study was to estimate the effect of incretins on fracture risk in the real-world situation by meta-analysis of the available population-based cohort data. Pubmed and Embase were searched for original articles investigating use of incretin agents, and fracture risk up to December 2015. Adjusted results were extracted and pooled by use of generic inverse variance methods, assuming a random-effects model. Neither current dipeptidyl peptidase 4-inhibitor use nor current glucagon-like peptide 1 receptor agonist use was associated with a decreased risk of fracture: pooled relative risk (pooled RR [95% confidence interval]: 1.02 [0.91-1.13] and 1.03 [0.87-1.22]), respectively. This meta-analysis demonstrated that current use of incretin agents, was not associated with decreased fracture risk. Our findings show the value of representative real-world populations, and the risks associated with suggesting benefits for medications on the basis of safety reporting in randomized controlled trials.


Assuntos
Fraturas Ósseas/epidemiologia , Hipoglicemiantes/administração & dosagem , Inibidores da Dipeptidil Peptidase IV/administração & dosagem , Inibidores da Dipeptidil Peptidase IV/farmacologia , Fraturas Ósseas/etiologia , Receptor do Peptídeo Semelhante ao Glucagon 1/agonistas , Humanos , Hipoglicemiantes/farmacologia , Incretinas/administração & dosagem , Incretinas/farmacologia , Ensaios Clínicos Controlados Aleatórios como Assunto , Risco
10.
BMC Med Imaging ; 17(1): 18, 2017 02 27.
Artigo em Inglês | MEDLINE | ID: mdl-28241752

RESUMO

BACKGROUND: Carbon-fiber-reinforced poly-ether-ether-ketone (CFR-PEEK) has superior radiolucency compared to other orthopedic implant materials, e.g. titanium or stainless steel, thus allowing metal-artifact-free postoperative monitoring by computed tomography (CT). Recently, high-resolution peripheral quantitative CT (HRpQCT) proved to be a promising technique to monitor the recovery of volumetric bone mineral density (vBMD), micro-architecture and biomechanical parameters in stable conservatively treated distal radius fractures. When using HRpQCT to monitor unstable distal radius fractures that require volar distal radius plating for fixation, radiolucent CFR-PEEK plates may be a better alternative to currently used titanium plates to allow for reliable assessment. In this pilot study, we assessed the effect of a volar distal radius plate made from CFR-PEEK on bone parameters obtained from HRpQCT in comparison to two titanium plates. METHODS: Plates were instrumented in separate cadaveric human fore-arms (n = 3). After instrumentation and after removal of the plates duplicate HRpQCT scans were made of the region covered by the plate. HRpQCT images were visually checked for artifacts. vBMD, micro-architectural and biomechanical parameters were calculated, and compared between the uninstrumented and instrumented radii. RESULTS: No visible image artifacts were observed in the CFR-PEEK plate instrumented radius, and errors in bone parameters ranged from -3.2 to 2.6%. In the radii instrumented with the titanium plates, severe image artifacts were observed and errors in bone parameters ranged between -30.2 and 67.0%. CONCLUSIONS: We recommend using CFR-PEEK plates in longitudinal in vivo studies that monitor the healing process of unstable distal radius fractures treated operatively by plating or bone graft ingrowth.


Assuntos
Placas Ósseas/classificação , Fixação Interna de Fraturas/instrumentação , Fraturas Ósseas/cirurgia , Rádio (Anatomia)/fisiopatologia , Tomografia Computadorizada por Raios X/métodos , Benzofenonas , Densidade Óssea , Feminino , Consolidação da Fratura , Humanos , Cetonas , Masculino , Projetos Piloto , Polietilenoglicóis , Polímeros , Rádio (Anatomia)/cirurgia , Titânio
11.
Respir Res ; 16: 32, 2015 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-25848824

RESUMO

Although osteoporosis and its related fractures are common in patients with COPD, patients at high risk of fracture are poorly identified, and consequently, undertreated. Since there are no fracture prevention guidelines available that focus on COPD patients, we developed a clinical approach to improve the identification and treatment of COPD patients at high risk of fracture. We organised a round-table discussion with 8 clinical experts in the field of COPD and fracture prevention in the Netherlands in December 2013. The clinical experts presented a review of the literature on COPD, osteoporosis and fracture prevention. Based on the Dutch fracture prevention guideline, they developed a 5-step clinical approach for fracture prevention in COPD. Thereby, they took into account both classical risk factors for fracture (low body mass index, older age, personal and family history of fracture, immobility, smoking, alcohol intake, use of glucocorticoids and increased fall risk) and COPD-specific risk factors for fracture (severe airflow obstruction, pulmonary exacerbations and oxygen therapy). Severe COPD (defined as postbronchodilator FEV1 < 50% predicted) was added as COPD-specific risk factor to the list of classical risk factors for fracture. The 5-step clinical approach starts with case finding using clinical risk factors, followed by risk evaluation (dual energy X-ray absorptiometry and imaging of the spine), differential diagnosis, treatment and follow-up. This systematic clinical approach, which is evidence-based and easy-to-use in daily practice by pulmonologists, should contribute to optimise fracture prevention in COPD patients at high risk of fracture.


Assuntos
Osteoporose/terapia , Fraturas por Osteoporose/prevenção & controle , Doença Pulmonar Obstrutiva Crônica/terapia , Comorbidade , Consenso , Procedimentos Clínicos , Técnicas de Apoio para a Decisão , Humanos , Osteoporose/diagnóstico , Osteoporose/epidemiologia , Fraturas por Osteoporose/diagnóstico , Fraturas por Osteoporose/epidemiologia , Valor Preditivo dos Testes , Prognóstico , Doença Pulmonar Obstrutiva Crônica/diagnóstico , Doença Pulmonar Obstrutiva Crônica/epidemiologia , Medição de Risco , Fatores de Risco
12.
Am J Med Genet A ; 167A(1): 169-73, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25425063

RESUMO

A 39-year-old male patient with a disharmonic intelligence profile and juvenile diabetes mellitus is described. At 14 months of age, minor facial dysmorphisms were noticed. He had delayed motor development, obesity at early age, and a diagnosis of insulin-dependent diabetes at the age of 10 years. He successfully completed secondary education and has been engaged in unskilled work activities, living independently. Upon examination, no psychiatric symptoms were present and his neuropsychological profile showed normal, although disharmonic, intellectual capacities and suboptimal social cognition. Genome wide array analysis identified an interstitial 12q24.31 deletion of 1.67 Mb encompassing hepatocyte nuclear factor-1-alpha gene (HNF1A), supporting a diagnosis of maturity-onset diabetes of the young. Results are discussed in relation to the few identified or published overlapping deletions. This is the first patient with normal intelligence in whom the presence of subtle facial dysmorphisms were decisive for introducing genetic analysis that, in turn, disclosed a rare form of diabetes necessitating modifications in treatment regimen. Clinicians, including those involved in psychiatry, should be aware of the diagnostic and prognostic value of atypical physical features in patients with a long history of complicated glucose regulation.


Assuntos
Deleção Cromossômica , Cromossomos Humanos Par 12/genética , Diabetes Mellitus Tipo 2/genética , Diabetes Mellitus Tipo 2/psicologia , Testes Neuropsicológicos , Adulto , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Gravidez , Adulto Jovem
13.
Curr Opin Rheumatol ; 26(4): 430-9, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24841229

RESUMO

PURPOSE OF REVIEW: The purpose of this review is to provide guidance to clinicians about which laboratory tests should be performed in patients with osteoporosis or with a recent fracture. RECENT FINDINGS: Newly diagnosed secondary osteoporosis and other metabolic bone diseases (SECOB) have been found in 5-48% of patients with osteoporosis. In patients with a recent fracture, new SECOB is found in 10-47% of patients with osteoporosis, and in 26-51% if all patients with a fracture regardless of bone mineral density (BMD) are screened. More than one SECOB can be found in the same patient, even when they have already known SECOB. In primary hyperparathyroidism, hyperthyroidism, hypercortisolism, and multiple myeloma, both SECOB and its treatment have an impact on BMD and fractures. For other SECOBs, no treatment is available, or there are no data about the effect of treatment of the SECOB on BMD and fractures. SUMMARY: We recommend performing the following tests in all patients with osteoporosis or a recent clinical fracture: calcium, phosphate, creatinine, albumin, erythrocyte sedimentation rate in all patients, 24 h urine calcium in men and serum testosterone in men less than 70 years. On indication, additional tests can be performed.


Assuntos
Doenças Ósseas Metabólicas/complicações , Fraturas Ósseas/etiologia , Osteoporose/complicações , Densidade Óssea , Humanos , Pessoa de Meia-Idade , Fatores de Risco
14.
Bone ; 177: 116921, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37769955

RESUMO

BACKGROUND: All musculoskeletal tissues are in a constant state of turnover, with a dynamic equilibrium between tissue protein synthesis and breakdown rates. The synthesis of protein allows musculoskeletal tissues to heal following injury. Yet, impaired tissue healing is observed following certain injuries, such as geriatric hip fractures. It is assumed that the regenerative properties of femoral head bone tissue are compromised following an intracapsular hip fracture and therefore hip replacement surgery is normally performed. However, the actual impact on in vivo bone protein synthesis rates has never been determined. DESIGN: In the present study, 10 patients (age: 79 ± 10 y, BMI: 24 ± 4 kg/m2) with an acute (<24 h) intracapsular hip fracture received a primed continuous intravenous infusion of L-[ring-13C6]-phenylalanine before and throughout their hip replacement surgery. Trabecular and cortical bone tissue from both the femoral head and proximal femur were sampled during surgery to assess protein synthesis rates of affected (femoral head) and unaffected (proximal femur) bone tissue, respectively. In addition, tissue samples of gluteus maximus muscle, synovium, ligamentum teres, and femoral head cartilage were collected. Tissue-specific protein synthesis rates were assessed by measuring L-[ring-13C6]-phenylalanine incorporation in tissue protein. RESULTS: Femoral head trabecular bone protein synthesis rates (0.056 [0.024-0.086] %/h) were lower when compared to proximal femur trabecular bone protein synthesis rates (0.081 [0.056-0.118] %/h; P = 0.043). Cortical bone protein synthesis rates did not differ between the femoral head and proximal femur (0.041 [0.021-0.078] and 0.045 [0.028-0.073] %/h, respectively; P > 0.05). Skeletal muscle, synovium, ligamentum teres, and femoral head cartilage protein synthesis rates averaged 0.080 [0.048-0.089], 0.093 [0.051-0.130], 0.121 [0.110-0.167], and 0.023 [0.015-0.039] %/h, respectively. CONCLUSION: In contrast to the general assumption that the femoral head is avital after an intracapsular displaced hip fracture in the elderly, our data show that bone protein synthesis is still ongoing in femoral head bone tissue during the early stages following an intracapsular hip fracture in older patients. Nonetheless, trabecular bone protein synthesis rates are lower in the femoral head when compared to the proximal femur in older patients following an acute intracapsular hip fracture. Trial register no: NL9036.

15.
Bone ; 154: 116225, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34634527

RESUMO

High-resolution peripheral quantitative computed tomography (HR-pQCT) devices can scan extremities at bone microstructural level in vivo and are used mainly in research of bone diseases. Two HR-pQCT scanners are commercially available to date: XtremeCT (first generation) and XtremeCT-II (second generation) from Scanco Medical AG (Switzerland). Recently, we have proposed an adaptive local thresholding (AT) technique and showed that it can improve quantification accuracy of bone microstructural parameters, with visually less sharp cone-beam CT (CBCT) images providing a similar accuracy than XtremeCT. The aim of this study was to evaluate whether the AT segmentation technique could enhance the accuracy of HR-pQCT in quantifying bone microstructural images and to assess whether the agreement between XtremeCT and XtremeCT-II could be improved. Nineteen radii were scanned with three scanners from Scanco Medical AG: (1) XtremeCT at 82 µm, (2) XtremeCT-II at 60.7 µm and (3) the small animal microCT scanner VivaCT40 at 19 µm voxel size. The scans were segmented applying two different methods, once following the manufacturer standard technique (ST), and once by means of AT. Three-dimensional (3D) morphological analysis was performed on the trabecular volume of the segmented images using the manufacturer's standard software to calculate bone volume fraction (BV/TV), trabecular thickness (Tb.Th), separation (Tb.Sp) and number (Tb.N). The average accuracy of XtremeCT improved from R2 = 0.76 (ST) to 0.85 (AT) and reached the same level of accuracy as XtremeCT-II with ST (R2 = 0.86). The largest improvements were obtained for BV/TV and Tb.Th. For XtremeCT-II, mean accuracy improved slightly from R2 = 0.86 (ST) to 0.89 (AT). For both segmentations and both scanners, the standard section was quantified slightly more accurate than the subchondral section. The agreement between the scanners was enhanced from R2 = 0.89 (ST) to 0.98 (AT). In conclusion, AT can enhance the accuracy of XtremeCT to quantify distal radius bone microstructural parameters close to XtremeCT-II level and increases the agreement between the two HR-pQCT scanners. High-resolution peripheral quantitative computed tomography, segmentation, bone microstructural parameters.


Assuntos
Osso Esponjoso , Rádio (Anatomia) , Densidade Óssea , Osso e Ossos , Osso Esponjoso/diagnóstico por imagem , Tomografia Computadorizada de Feixe Cônico , Microtomografia por Raio-X/métodos
16.
Bone Rep ; 17: 101614, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36062034

RESUMO

Purpose: In this descriptive study, we examined the incidence of fractures in patients with newly treated type 2 diabetes mellitus (T2D) compared to matched reference population. Methods: Participants from the UK Clinical Practice research datalink (CPRD) GOLD (1987-2017), aged ≥30 years, with a T2D diagnosis code and a first prescription for a non-insulin anti-diabetic drug (n = 124,328) were included. Cases with T2D were matched by year of birth, sex and practice to a reference population (n = 124,328), the mean follow-up was 7.7 years. Crude fracture incidence rates (IRs) and incidence rate ratios (IRRs) were calculated. Analyses were stratified by fracture site and sex and additionally adjusted for BMI, smoking status, alcohol use and history of any fracture at index date. Results: The IR of all fractures and major osteoporotic fractures was lower in T2D compared to the reference population (IRR 0.97; 95%CI 0.94-0.99). The IRs were lower for clavicle (IRR 0.67; 0.56-0.80), radius/ulna (IRR 0.81; 0.75-0.86) and vertebral fractures (0.83; 0.75-0.92) and higher for ankle (IRR 1.16; 95%CI 1.06-1.28), foot (1.11; 1.01-1.22), tibia/fibula (1.17; 1.03-1.32) and humerus fractures (1.11; 1.03-1.20). Differences in IRs at various fracture sites between T2D and the reference population were more pronounced in women than in men. In contrast, BMI adjusted IRs for all fractures (IRR 1.07; 1.04-1.10) and most individual fracture sites were significantly higher in T2D, especially in women. Conclusion: The crude incidence of all fractures was marginally lower in patients with newly treated T2D compared to the matched reference population but differed according to fracture site, especially in women. BMI adjusted analyses resulted in higher incidence rates in T2D at almost all fracture sites compared to crude incidence rates and this was more pronounced in women than in men. This implies that BMI may have a protective impact on the crude incidence of fractures, especially in women with newly treated T2D.

17.
Sci Rep ; 12(1): 7337, 2022 05 05.
Artigo em Inglês | MEDLINE | ID: mdl-35513556

RESUMO

Mortality in type 2 diabetes, is determined not only by classical complications, but also by comorbidities, and is linked to hyperglycaemia and apparent even in prediabetes. We aimed to comprehensively investigate, in a population-based cohort, health burden defined as the presence of comorbidities in addition to classical complications and cardiometabolic risk factors, in not only type 2 diabetes but also prediabetes. Such population-based study has not been performed previously. Extensive phenotyping was performed in 3,410 participants of the population-based Maastricht Study (15.0% prediabetes and 28.6% type 2 diabetes) to assess presence of 17 comorbidities, six classical complications, and ten cardiometabolic risk factors. These were added up into individual and combined sum scores and categorized. Group differences were studied with multinomial regression analyses adjusted for age and sex. Individuals with type 2 diabetes and prediabetes, as compared to normal glucose metabolism (NGM), had greater comorbidities, classical complications, cardiometabolic risk factors and combined sum scores (comorbidities sum score ≥ 3: frequencies (95% CI) 61.5% (57.6;65.4) and 41.2% (36.5;45.9) vs. 25.4% (23.5;27.4), p-trend < 0.001; classical complications ≥ 2 (26.6% (23.1;30.1; P < 0.001 vs. NGM) and 10.1% (7.8;12.7; P = 0.065 vs NGM) vs. 8.0% (6.9;9.3)); cardiometabolic risk factors ≥ 6 (39.7% (35.9;43.4) and 28.5% (24.5;32.6) vs. 14.0% (12.5;15.6); p-trend < 0.001); combined ≥ 8 (66.6% (62.7;70.5) and 48.4% (43.7;53.1) vs. 26.0%(24.1;28.0), p-trend < 0.001). Type 2 diabetes and prediabetes health burden was comparable to respectively 32 and 14 years of ageing. Our population-based study shows, independently of age and sex, a considerable health burden in both type 2 diabetes and prediabetes, which to a substantial extent can be attributed to comorbidities in addition to classical complications and cardiometabolic risk factors. Our findings emphasize the necessity of comorbidities' awareness in (pre)diabetes and for determining the exact role of hyperglycaemia in the occurrence of comorbidities.


Assuntos
Diabetes Mellitus Tipo 2 , Hiperglicemia , Estado Pré-Diabético , Glicemia/metabolismo , Estudos de Coortes , Diabetes Mellitus Tipo 2/complicações , Diabetes Mellitus Tipo 2/epidemiologia , Humanos , Hiperglicemia/complicações , Estado Pré-Diabético/complicações , Estado Pré-Diabético/epidemiologia , Fatores de Risco
18.
BMJ Open ; 12(5): e054315, 2022 05 24.
Artigo em Inglês | MEDLINE | ID: mdl-35613823

RESUMO

INTRODUCTION: Patients with osteoporosis may suffer from a fracture after minimal trauma. Osteoporotic vertebral compression fractures (OVCFs) are among the most common fractures, often leading to substantial pain. There is a need for evidence-based conservative treatment to aid in the management of OVCFs. The objective of this randomised controlled trial (RCT) is to evaluate the effectiveness and cost-effectiveness of dynamic bracing in addition to standard care for improving quality of life (QoL) in patients suffering from an OVCF. METHODS AND ANALYSIS: Ninety-eight postmenopausal women from two academic and four community hospitals with a recent symptomatic thoracolumbar OVCF will be randomised into either the standard care or dynamic bracing group. In the dynamic bracing group, the Spinova Osteo orthosis will be used in addition to standard care. Standard care comprises pain control with analgesics, physical therapy and osteoporosis medication. The primary outcome parameter is QoL 1 year after inclusion, as measured by the Quality of Life Questionnaire of the European Foundation for Osteoporosis (QUALEFFO-41). Secondary outcome parameters are pain, pain medication used, functional disability, sagittal spinal alignment, recurrence rate of OVCFs and physical activity in daily life. A trial-based economic evaluation consisting of both cost-effectiveness analysis and cost-utility analysis will be performed based on empirical data obtained in the RCT. A process evaluation will assess the feasibility of dynamic bracing. All outcomes will be assessed at baseline, 6 weeks, 3 months, 6 months, 9 months and 12 months. ETHICS AND DISSEMINATION: Ethical approval has been granted by the Medical Ethics Committee, University Hospital Maastricht and Maastricht University (METC azM/UM) (NL74552.068.20/METC 20-055). Patients will be included only after verification of eligibility and obtaining written informed consent. Results will be disseminated via the Dutch National Osteoporosis Patient Society and via publications and conferences. TRIAL REGISTRATION NUMBER: NL8746.


Assuntos
Fraturas por Compressão , Osteoporose , Fraturas por Osteoporose , Fraturas da Coluna Vertebral , Análise Custo-Benefício , Feminino , Seguimentos , Fraturas por Compressão/terapia , Humanos , Estudos Multicêntricos como Assunto , Osteoporose/complicações , Osteoporose/terapia , Fraturas por Osteoporose/terapia , Dor , Qualidade de Vida , Ensaios Clínicos Controlados Aleatórios como Assunto , Fraturas da Coluna Vertebral/terapia
19.
Curr Osteoporos Rep ; 9(1): 36-42, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21113692

RESUMO

Inadequate serum 25-hydroxyvitamin D (25[OH]D) concentrations are associated with muscle weakness, decreased physical performance, and increased propensity in falls and fractures. This paper discusses several aspects with regard to vitamin D status and supplementation when treating patients with osteoporosis in relation to risks and prevention of falls and fractures. Based on evidence from literature, adequate supplementation with at least 700 IU of vitamin D, preferably cholecalciferol, is required for improving physical function and prevention of falls and fractures. Additional calcium supplementation may be considered when dietary calcium intake is below 700 mg/day. For optimal bone mineral density response in patients treated with antiresorptive or anabolic therapy, adequate vitamin D and calcium supplementation is also necessary. Monitoring of 25(OH)D levels during follow-up and adjustment of vitamin D supplementation should be considered to reach and maintain adequate serum 25(OH)D levels of at least 50 nmol/L, preferably greater than 75 nmol/L in all patients.


Assuntos
Osteoporose/tratamento farmacológico , Deficiência de Vitamina D/complicações , Vitamina D/análogos & derivados , Vitamina D/administração & dosagem , Acidentes por Quedas/prevenção & controle , Densidade Óssea/efeitos dos fármacos , Suplementos Nutricionais , Fraturas Ósseas/etiologia , Humanos , Metanálise como Assunto , Osteoporose/complicações , Osteoporose/prevenção & controle , Ensaios Clínicos Controlados Aleatórios como Assunto , Vitamina D/sangue
20.
Curr Osteoporos Rep ; 9(3): 167-72, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21695407

RESUMO

We discussed whether we are able to select a subgroup of patients with osteopenia having a high fracture risk, in which anti-osteoporotic drug treatment can be advocated. We concluded that in individuals in whom, based on clinical risk factors, a dual-energy x-ray absorptiometry (DXA) was performed in which osteopenia was diagnosed, anti-osteoporotic treatment should be prescribed in those patients with prevalent vertebral fractures, and in patients chronically using glucocorticoids, in a dosage of 7.5 mg per day or more. Although recent developments with regard to high-resolution imaging techniques (eg, peripheral quantitative computed tomography) seem to be promising, until now they do not provide substantial more reliable information than DXA in the prediction of fractures. We think that more data are urgently needed, since safe and effective drugs are available, but there is uncertainty to which patients with osteopenia these drugs should be prescribed.


Assuntos
Conservadores da Densidade Óssea/uso terapêutico , Doenças Ósseas Metabólicas/diagnóstico , Doenças Ósseas Metabólicas/tratamento farmacológico , Fraturas Ósseas/epidemiologia , Fraturas Ósseas/prevenção & controle , Glucocorticoides/efeitos adversos , Humanos , Vértebras Lombares/lesões , Fatores de Risco , Fraturas da Coluna Vertebral/epidemiologia , Fraturas da Coluna Vertebral/prevenção & controle
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa