Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 64
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Eur J Nucl Med Mol Imaging ; 51(10): 3098-3108, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38376805

RESUMO

PURPOSE: In radioguided surgery (RGS), radiopharmaceuticals are used to generate preoperative roadmaps (e.g., PET/CT) and to facilitate intraoperative tracing of tracer avid lesions. Within RGS, there is a push toward the use of receptor-targeted radiopharmaceuticals, a trend that also has to align with the surgical move toward minimal invasive robotic surgery. Building on our initial ex vivo evaluation, this study investigates the clinical translation of a DROP-IN ß probe in robotic PSMA-guided prostate cancer surgery. METHODS: A clinical-grade DROP-IN ß probe was developed to support the detection of PET radioisotopes (e.g., 68 Ga). The prototype was evaluated in 7 primary prostate cancer patients, having at least 1 lymph node metastases visible on PSMA-PET. Patients were scheduled for radical prostatectomy combined with extended pelvic lymph node dissection. At the beginning of surgery, patients were injected with 1.1 MBq/kg of [68Ga]Ga-PSMA. The ß probe was used to trace PSMA-expressing lymph nodes in vivo. To support intraoperative decision-making, a statistical software algorithm was defined and optimized on this dataset to help the surgeon discriminate between probe signals coming from tumors and healthy tissue. RESULTS: The DROP-IN ß probe helped provide the surgeon with autonomous and highly maneuverable tracer detection. A total of 66 samples (i.e., lymph node specimens) were analyzed in vivo, of which 31 (47%) were found to be malignant. After optimization of the signal cutoff algorithm, we found a probe detection rate of 78% of the PSMA-PET-positive samples, a sensitivity of 76%, and a specificity of 93%, as compared to pathologic evaluation. CONCLUSION: This study shows the first-in-human use of a DROP-IN ß probe, supporting the integration of ß radio guidance and robotic surgery. The achieved competitive sensitivity and specificity help open the world of robotic RGS to a whole new range of radiopharmaceuticals.


Assuntos
Algoritmos , Neoplasias da Próstata , Procedimentos Cirúrgicos Robóticos , Cirurgia Assistida por Computador , Humanos , Masculino , Neoplasias da Próstata/cirurgia , Neoplasias da Próstata/diagnóstico por imagem , Cirurgia Assistida por Computador/métodos , Procedimentos Cirúrgicos Robóticos/métodos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Idoso , Compostos Radiofarmacêuticos , Radioisótopos de Gálio , Partículas beta , Pessoa de Meia-Idade , Glutamato Carboxipeptidase II/metabolismo , Isótopos de Gálio , Prostatectomia , Metástase Linfática/diagnóstico por imagem
2.
Eur J Nucl Med Mol Imaging ; 51(10): 3089-3097, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38233608

RESUMO

PURPOSE: The recently introduced tethered DROP-IN gamma probe has revolutionized the way robotic radioguided surgery is performed, fully exploiting the nature of steerable robotic instruments. Given this success, the current first-in-human study investigates if the DROP-IN can also provide benefit in combination with steerable non-robotic instruments during conventional laparoscopic surgery, showing equivalence or even benefit over a traditional rigid gamma probe. METHODS: The evaluation was performed in ten patients during laparoscopic cervical (n = 4) and endometrial (n = 6) cancer sentinel lymph node (SLN) procedures. Surgical guidance was provided using the hybrid, or bi-modal, SLN tracer ICG-99mTc-nanocolloid. SLN detection was compared between the traditional rigid laparoscopic gamma probe, the combination of a DROP-IN gamma probe and a steerable laparoscopic instrument (LaproFlex), and fluorescence imaging. RESULTS: The gynecologists experienced an enlarged freedom of movement when using the DROP-IN + LaproFlex combination compared to the rigid laparoscopic probe, making it possible to better isolate the SLN signal from background signals. This did not translate into a change in the SLN find rate yet. In both cervical and endometrial cancer combined, the rigid probe and DROP-IN + LaproFlex combination provided an equivalent detection rate of 96%, while fluorescence provided 85%. CONCLUSION: We have successfully demonstrated the in-human use of steerable DROP-IN radioguidance during laparoscopic cervical and endometrial cancer SLN procedures, expanding the utility beyond robotic procedures. Indicating an improved surgical experience, these findings encourage further investigation and consideration on a path towards routine clinical practice and improved patient outcome. TRIAL REGISTRATION: HCB/2021/0777 and NCT04492995; https://clinicaltrials.gov/study/NCT04492995.


Assuntos
Neoplasias do Endométrio , Linfonodo Sentinela , Neoplasias do Colo do Útero , Humanos , Feminino , Neoplasias do Colo do Útero/diagnóstico por imagem , Neoplasias do Colo do Útero/cirurgia , Linfonodo Sentinela/diagnóstico por imagem , Linfonodo Sentinela/cirurgia , Pessoa de Meia-Idade , Neoplasias do Endométrio/diagnóstico por imagem , Neoplasias do Endométrio/cirurgia , Neoplasias do Endométrio/patologia , Biópsia de Linfonodo Sentinela/métodos , Biópsia de Linfonodo Sentinela/instrumentação , Laparoscopia , Idoso , Adulto , Cirurgia Assistida por Computador/métodos , Cirurgia Assistida por Computador/instrumentação
3.
BJU Int ; 134(1): 81-88, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38346924

RESUMO

OBJECTIVE: To investigate whether combination treatment of prostate-specific membrane antigen (PSMA)-based radioguided surgery (RGS) with short-term androgen deprivation therapy (ADT) improves oncological outcomes in men with oligorecurrent prostate cancer (PCa) as compared to treatment with short-term ADT only. METHODS: The TRACE-II study is an investigator-initiated, prospective, randomised controlled clinical trial. Patients (aged >18 years) with hormone-sensitive recurrent PCa after radical prostatectomy or radiotherapy (brachytherapy or external beam radiotherapy), with involvement of ≤2 lymph nodes or local oligorecurrent disease within the pelvis as determined by PSMA positron emission tomography (PET)/computed tomography (CT) are randomly assigned in a 1:1 ratio between 6-month ADT (Arm A) or 6-month ADT plus RGS (Arm B). The primary objective is to determine clinical progression-free survival (CPFS) at 24 months. After PSMA-RGS, CPFS is defined as the time between the start of treatment and the appearance of a re-recurrence (any N1 or M1) as suggested by PSMA-PET/CT or symptoms related to progressive PCa, or death from any cause. The secondary objectives include metastasis-free survival at 2, 5 and 10 years, biochemical progression-free survival at 2 years, and patient-reported quality of life at 2, 5 and 10 years. A total of 60 patients, 30 per arm, will be included. The trial is powered (80%) to detect at least a 30% absolute difference in CPFS between the two study arms in the period 2 years after randomisation. We expect to enrol the required participants in 3 years. The study has an expected duration of 5 years in total. CONCLUSIONS: Combining RGS with short-term ADT might be oncologically beneficial for patients with oligorecurrent PCa. In this first randomised controlled trial, we are investigating the potential oncological benefits of this combined treatment, while also focusing on maintaining quality of life.


Assuntos
Recidiva Local de Neoplasia , Neoplasias da Próstata , Humanos , Masculino , Neoplasias da Próstata/cirurgia , Neoplasias da Próstata/terapia , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Estudos Prospectivos , Cirurgia Assistida por Computador/métodos , Compostos Radiofarmacêuticos/uso terapêutico , Prostatectomia/métodos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Antagonistas de Androgênios/uso terapêutico , Glutamato Carboxipeptidase II/metabolismo , Idoso , Pessoa de Meia-Idade
4.
Malar J ; 23(1): 111, 2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38641838

RESUMO

BACKGROUND: Sporozoites (SPZ), the infective form of Plasmodium falciparum malaria, can be inoculated into the human host skin by Anopheline mosquitoes. These SPZ migrate at approximately 1 µm/s to find a blood vessel and travel to the liver where they infect hepatocytes and multiply. In the skin they are still low in number (50-100 SPZ) and vulnerable to immune attack by antibodies and skin macrophages. This is why whole SPZ and SPZ proteins are used as the basis for most malaria vaccines currently deployed and undergoing late clinical testing. Mosquitoes typically inoculate SPZ into a human host between 14 and 25 days after their previous infective blood meal. However, it is unknown whether residing time within the mosquito affects SPZ condition, infectivity or immunogenicity. This study aimed to unravel how the age of P. falciparum SPZ in salivary glands (14, 17, or 20 days post blood meal) affects their infectivity and the ensuing immune responses. METHODS: SPZ numbers, viability by live/dead staining, motility using dedicated sporozoite motility orienting and organizing tool software (SMOOT), and infectivity of HC-04.j7 liver cells at 14, 17 and 20 days after mosquito feeding have been investigated. In vitro co-culture assays with SPZ stimulated monocyte-derived macrophages (MoMɸ) and CD8+ T-cells, analysed by flow cytometry, were used to investigate immune responses. RESULTS: SPZ age did not result in different SPZ numbers or viability. However, a markedly different motility pattern, whereby motility decreased from 89% at day 14 to 80% at day 17 and 71% at day 20 was observed (p ≤ 0.0001). Similarly, infectivity of day 20 SPZ dropped to ~ 50% compared with day 14 SPZ (p = 0.004). MoMɸ were better able to take up day 14 SPZ than day 20 SPZ (from 7.6% to 4.1%, p = 0.03) and displayed an increased expression of pro-inflammatory CD80, IL-6 (p = 0.005), regulatory markers PDL1 (p = 0.02), IL-10 (p = 0.009) and cytokines upon phagocytosis of younger SPZ. Interestingly, co-culture of these cells with CD8+ T-cells revealed a decreased expression of activation marker CD137 and cytokine IFNγ compared to their day 20 counterparts. These findings suggest that older (day 17-20) P. falciparum SPZ are less infectious and have decreased immune regulatory potential. CONCLUSION: Overall, this data is a first step in enhancing the understanding of how mosquito residing time affects P. falciparum SPZ and could impact the understanding of the P. falciparum infectious reservoir and the potency of whole SPZ vaccines.


Assuntos
Culicidae , Vacinas Antimaláricas , Malária Falciparum , Animais , Humanos , Esporozoítos , Linfócitos T CD8-Positivos , Envelhecimento , Plasmodium falciparum
5.
Artigo em Inglês | MEDLINE | ID: mdl-37999812

RESUMO

PURPOSE: To obtain initial data on sentinel lymph node (SLN) visualisation by pre-operative magnetic resonance imaging (MRI) and intra-operative bimodal SLN identification using a new magnetic fluorescent hybrid tracer in prostate cancer (PCa) patients. METHODS: Ten patients at > 5% risk for lymph node (LN) invasion were included. The day before surgery, a magnetic fluorescent hybrid tracer consisting of superparamagnetic iron oxide nanoparticles (SPION) and indocyanine green was transrectally injected into the prostate. Five hours after injection, transversal pelvic MRI scans were recorded and T2*-weighed images were screened for pelvic LNs with SPION uptake. Intra-operatively, magnetically active and/or fluorescent SLNs were detected by a handheld magnetometer and near-infrared fluorescence imaging (FI). Extended pelvic lymph node dissection (PLND) and radical prostatectomy completed the surgery. All resected specimens were checked ex situ for magnetic activity and fluorescence and were histopathologically examined. RESULTS: Pre-operative MRI identified 145 pelvic LNs with SPION uptake. In total, 75 (median 6, range 3‒13) magnetically active SLNs were resected, including 14 SLNs not seen on MRI. FI identified 89 fluorescent LNs (median 8.5, range 4‒13) of which 15 LNs were not magnetically active. Concordance of the different techniques was 70% for pre-operative MRI vs. magnetometer-guided PLND and 88% for magnetic vs. fluorescent SLN detection. CONCLUSION: These are the first promising results of bimodal, magnetic fluorescent SLN detection in PCa patients. Our magnetic fluorescent hybrid approach provides the surgeon a pre-operative lymphatic roadmap by using MRI and intra-operative visual guidance through the application of a fluorescent lymphatic agent. The diagnostic accuracy of our new hybrid approach has to be evaluated in further studies. TRIAL REGISTRATION: DRKS00032808. Registered 04 October 2023, retrospectively registered.

6.
Eur J Nucl Med Mol Imaging ; 50(8): 2282-2291, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36929210

RESUMO

BACKGROUND: Lymph node (LN) metastasis is a relevant predictor for survival in patients with a.o. penile cancer (PeCa), malignant melanoma. The sentinel node (SN) procedure comprises targeted resection of the first tumour-draining SNs. Here, the hybrid tracer indocyanine green (ICG)-99mTc-nanocolloid has been used for several years to combine optical and nuclear detection. Recently, the resource of the nanocolloid precursor stopped production and the precursor was replaced by a different but chemically comparable colloid, nanoscan. Our aim was to study the performance of ICG-99mTc-nanoscan compared to ICG-99mTc-nanocolloid from a nuclear and surgical perspective. METHODS: Twenty-four patients with either PeCa or head-and-neck (H&N) melanoma and scheduled for a SN procedure were included. The initial group (n = 11) received ICG-99mTc-nanocolloid until no longer available; the second group (n = 13) received ICG-99mTc-nanoscan. Tracer uptake was assessed on lymphoscintigraphy and single-photon emission (SPECT). Intraoperatively, SNs were identified using gamma tracing and fluorescence imaging. Ex vivo (back-table) measurements were conducted to quantify the fluorescence emissions. Chemical analysis was performed to compare the ICG assembly on both precursors. RESULTS: The mean tracer uptake in the SNs was similar for ICG-99mTc-nanocolloid (2.2 ± 4.3%ID) and ICG-99mTc-nanoscan (1.8 ± 2.6%ID; p = 0.68). 3 SNs (interquartile range (IQR) 3-4) were detected on lymphoscintigraphy in PeCa patients receiving ICG-99mTc-nanoscan compared to 2 SNs (IQR 2-3) in PeCa patients receiving ICG-99mTc-nanocolloid (p = 0.045), no differences were observed in H&N patients. Back-table measurements of resected SNs revealed a lower total fluorescence intensity in the ICG-99mTc-nanoscan group (24*109 arbitrary units (A.U) IQR 1.6*109-14*109 in the ICG-99mTc-nanocolloid group versus 4.6*109 A.U. IQR 2.4*109-42*109 in the ICG-99mTc-nanoscan group, p = 0.0054). This was consistent with a larger degree of "stacked" ICG observed in the nanoscan formulation. No tracer-related adverse events were reported. CONCLUSIONS: Based on this retrospective analysis, we can conclude that ICG-99mTc-nanoscan has similar capacity for SN identification as ICG-99mTc-nanocolloid and can safely be implemented in SN procedures.


Assuntos
Melanoma , Medicina Nuclear , Neoplasias Penianas , Linfonodo Sentinela , Masculino , Humanos , Verde de Indocianina , Biópsia de Linfonodo Sentinela/métodos , Estudos Retrospectivos , Linfonodo Sentinela/cirurgia , Melanoma/diagnóstico por imagem , Melanoma/cirurgia , Melanoma/patologia , Compostos Radiofarmacêuticos , Metástase Linfática , Neoplasias Penianas/patologia , Agregado de Albumina Marcado com Tecnécio Tc 99m
7.
Artigo em Inglês | MEDLINE | ID: mdl-38012448

RESUMO

PURPOSE: Prostate-specific membrane antigen (PSMA) is increasingly considered as a molecular target to achieve precision surgery for prostate cancer. A Delphi consensus was conducted to explore expert views in this emerging field and to identify knowledge and evidence gaps as well as unmet research needs that may help change practice and improve oncological outcomes for patients. METHODS: One hundred and five statements (scored by a 9-point Likert scale) were distributed through SurveyMonkey®. Following evaluation, a consecutive second round was performed to evaluate consensus (16 statements; 89% response rate). Consensus was defined using the disagreement index, assessed by the research and development project/University of California, Los Angeles appropriateness method. RESULTS: Eighty-six panel participants (72.1% clinician, 8.1% industry, 15.1% scientists, and 4.7% other) participated, most with a urological background (57.0%), followed by nuclear medicine (22.1%). Consensus was obtained on the following: (1) The diagnostic PSMA-ligand PET/CT should ideally be taken < 1 month before surgery, 1-3 months is acceptable; (2) a 16-20-h interval between injection of the tracer and surgery seems to be preferred; (3) PSMA targeting is most valuable for identification of nodal metastases; (4) gamma, fluorescence, and hybrid imaging are the preferred guidance technologies; and (5) randomized controlled clinical trials are required to define oncological value. Regarding surgical margin assessment, the view on the value of PSMA-targeted surgery was neutral or inconclusive. A high rate of "cannot answer" responses indicates further study is necessary to address knowledge gaps (e.g., Cerenkov or beta-emissions). CONCLUSIONS: This Delphi consensus provides guidance for clinicians and researchers that implement or develop PSMA-targeted surgery technologies. Ultimately, however, the consensus should be backed by randomized clinical trial data before it may be implemented within the guidelines.

8.
Eur J Nucl Med Mol Imaging ; 48(13): 4201-4224, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34185136

RESUMO

Molecular imaging is one of the pillars of precision surgery. Its applications range from early diagnostics to therapy planning, execution, and the accurate assessment of outcomes. In particular, molecular imaging solutions are in high demand in minimally invasive surgical strategies, such as the substantially increasing field of robotic surgery. This review aims at connecting the molecular imaging and nuclear medicine community to the rapidly expanding armory of surgical medical devices. Such devices entail technologies ranging from artificial intelligence and computer-aided visualization technologies (software) to innovative molecular imaging modalities and surgical navigation (hardware). We discuss technologies based on their role at different steps of the surgical workflow, i.e., from surgical decision and planning, over to target localization and excision guidance, all the way to (back table) surgical verification. This provides a glimpse of how innovations from the technology fields can realize an exciting future for the molecular imaging and surgery communities.


Assuntos
Realidade Aumentada , Procedimentos Cirúrgicos Robóticos , Cirurgia Assistida por Computador , Inteligência Artificial , Humanos , Imagem Molecular
9.
Eur J Nucl Med Mol Imaging ; 48(13): 4142-4151, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34031721

RESUMO

PURPOSE: Decision-making and dexterity, features that become increasingly relevant in (robot-assisted) minimally invasive surgery, are considered key components in improving the surgical accuracy. Recently, DROP-IN gamma probes were introduced to facilitate radioguided robotic surgery. We now studied if robotic DROP-IN radioguidance can be further improved using tethered Click-On designs that integrate gamma detection onto the robotic instruments themselves. METHODS: Using computer-assisted drawing software, 3D printing and precision machining, we created a Click-On probe containing two press-fit connections and an additional grasping moiety for a ProGrasp instrument combined with fiducials that could be video tracked using the Firefly laparoscope. Using a dexterity phantom, the duration of the specific tasks and the path traveled could be compared between use of the Click-On or DROP-IN probe. To study the impact on surgical decision-making, we performed a blinded study, in porcine models, wherein surgeons had to identify a hidden 57Co-source using either palpation or Click-On radioguidance. RESULTS: When assembled onto a ProGrasp instrument, while preserving grasping function and rotational freedom, the fully functional prototype could be inserted through a 12-mm trocar. In dexterity assessments, the Click-On provided a 40% reduction in movements compared to the DROP-IN, which converted into a reduction in time, path length, and increase in straightness index. Radioguidance also improved decision-making; task-completion rate increased by 60%, procedural time was reduced, and movements became more focused. CONCLUSION: The Click-On gamma probe provides a step toward full integration of radioguidance in minimal invasive surgery. The value of this concept was underlined by its impact on surgical dexterity and decision-making.


Assuntos
Procedimentos Cirúrgicos Robóticos , Robótica , Animais , Procedimentos Cirúrgicos Minimamente Invasivos , Suínos
10.
Q J Nucl Med Mol Imaging ; 65(3): 229-243, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34014062

RESUMO

In locally or locally advanced solid tumors, surgery still remains a fundamental treatment method. However, conservative resection is associated with high collateral damage and functional limitations of the patient. Furthermore, the presence of residual tumor tissue following conservative surgical treatment is currently a common cause of locally recurrent cancer or of distant metastases. Reliable intraoperative detection of small cancerous tissue would allow surgeons to selectively resect malignant areas: this task can be achieved by means of image-guided surgery, such as beta radioguided surgery (RGS). In this paper, a comprehensive review of beta RGS is given, starting from the physical principles that differentiate beta from gamma radiation, that already has its place in current surgical practice. Also, the recent clinical feasibility of using Cerenkov radiation is discussed. Despite being first proposed several decades ago, only in the last years a remarkable interest in beta RGS has been observed, probably driven by the diffusion of PET radiotracers. Today several different approaches are being pursued to assess the effectiveness of such a technique, including both beta+ and beta- emitting radiopharmaceuticals. Beta RGS shows some peculiarities that can present it as a very promising complementary technique to standard procedures. Good results are being obtained in several tests, both ex vivo and in vivo. This might however be the time to initiate the trials to demonstrate the real clinical value of these technologies with seemingly clear potential.


Assuntos
Recidiva Local de Neoplasia , Cirurgia Assistida por Computador , Humanos , Compostos Radiofarmacêuticos
11.
Q J Nucl Med Mol Imaging ; 65(3): 244-260, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34105338

RESUMO

INTRODUCTION: Nuclear medicine has a crucial role in interventional strategies where a combination between the increasing use of targeted radiotracers and intraprocedural detection modalities enable novel, but often complex, targeted procedures in both the fields of interventional radiology and surgery. 3D navigation approaches could assist the interventional radiologist or surgeon in such complex procedures. EVIDENCE ACQUISITION: This review aimed to provide a comprehensive overview of the current application of computer-assisted navigation strategies based on nuclear imaging to assist in interventional radiology and image-guided surgery. This work starts with a brief overview of the typical navigation workflow from a technical perspective, which is followed by the different clinical applications organized based on their anatomical organ of interest. EVIDENCE SYNTHESIS: Although many studies have proven the feasibility of PET- and SPECT-based navigation strategies for various clinical applications in both interventional radiology and surgery, the strategies are spread widely in both navigation workflows and clinical indications, evaluated in small patient groups. Hence, no golden standard has yet been established. CONCLUSIONS: Despite that the clinical outcome is yet to be determined in large patient cohorts, navigation seems to be a promising technology to translate nuclear medicine findings, provided by PET- and SPECT-based molecular imaging, to the intervention and operating room. Interventional Nuclear Medicine (iNM) has an exciting future to come using both PET- and SPECT-based navigation.


Assuntos
Medicina Nuclear , Cirurgia Assistida por Computador , Humanos , Tomografia por Emissão de Pósitrons , Radiologia Intervencionista , Tomografia Computadorizada de Emissão de Fóton Único
12.
Q J Nucl Med Mol Imaging ; 65(1): 4-19, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33494584

RESUMO

Within interventional nuclear medicine (iNM) a prominent role is allocated for the sub-discipline of radioguided surgery. Unique for this discipline is the fact that an increasing number of clinical indications (e.g. lymphatic mapping, local tumor demarcation and/or tumor receptor targeted applications) have been adopted into routine care. The clinical integration is further strengthened by technical innovations in chemistry and engineering that enhance the translational potential of radioguided procedures in iNM. Together, these features not only ensure ongoing expansion of iNM but also warrant a lasting clinical impact for the sub-discipline of radioguided surgery.


Assuntos
Neoplasias/diagnóstico por imagem , Cintilografia/métodos , Compostos Radiofarmacêuticos/química , Humanos , Neoplasias/cirurgia , Medicina Nuclear , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Compostos Radiofarmacêuticos/administração & dosagem , Compostos Radiofarmacêuticos/metabolismo , Fluxo de Trabalho
13.
Mol Imaging ; 19: 1536012120962333, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33125289

RESUMO

With the rise of fluorescence-guided surgery, it has become evident that different types of fluorescence signals can provide value in the surgical setting. Hereby a different range of targets have been pursued in a great variety of surgical indications. One of the future challenges lies in combining complementary fluorescent readouts during one and the same surgical procedure, so-called multi-wavelength fluorescence guidance. In this review we summarize the current clinical state-of-the-art in multi-wavelength fluorescence guidance, basic technical concepts, possible future extensions of existing clinical indications and impact that the technology can bring to clinical care.


Assuntos
Cirurgia Assistida por Computador , Estudos de Viabilidade , Fluorescência
14.
World J Urol ; 38(10): 2359-2366, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31776737

RESUMO

PURPOSE: The aim of the current narrative review was to summarize the available evidence in the literature on artificial intelligence (AI) methods that have been applied during robotic surgery. METHODS: A narrative review of the literature was performed on MEDLINE/Pubmed and Scopus database on the topics of artificial intelligence, autonomous surgery, machine learning, robotic surgery, and surgical navigation, focusing on articles published between January 2015 and June 2019. All available evidences were analyzed and summarized herein after an interactive peer-review process of the panel. LITERATURE REVIEW: The preliminary results of the implementation of AI in clinical setting are encouraging. By providing a readout of the full telemetry and a sophisticated viewing console, robot-assisted surgery can be used to study and refine the application of AI in surgical practice. Machine learning approaches strengthen the feedback regarding surgical skills acquisition, efficiency of the surgical process, surgical guidance and prediction of postoperative outcomes. Tension-sensors on the robotic arms and the integration of augmented reality methods can help enhance the surgical experience and monitor organ movements. CONCLUSIONS: The use of AI in robotic surgery is expected to have a significant impact on future surgical training as well as enhance the surgical experience during a procedure. Both aim to realize precision surgery and thus to increase the quality of the surgical care. Implementation of AI in master-slave robotic surgery may allow for the careful, step-by-step consideration of autonomous robotic surgery.


Assuntos
Inteligência Artificial , Procedimentos Cirúrgicos Robóticos/métodos , Procedimentos Cirúrgicos Urológicos/métodos , Humanos , Salas Cirúrgicas
15.
Eur J Nucl Med Mol Imaging ; 46(1): 49-53, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30054696

RESUMO

PURPOSE: Radioguided surgery has been widely used for clinical procedures such as sentinel node resections. In the (robot-assisted) laparoscopic setting radioguidance is realized using laparoscopic gamma probes, which have limited maneuverability. To increase the rotational freedom, a tethered DROP-IN gamma probe was designed. Here we present the first in vivo feasibility study of this technology in prostate cancer patients. METHODS: Ten patients scheduled for a sentinel node procedure received four injections into the prostate with (indocyanine green-)99mTechnetium-nanocolloid and underwent preoperative imaging (lymphoscintigraphy and SPECT/CT). The DROP-IN probe was inserted via the assistant port, still permitting the insertion and usage of additional laparoscopic tools. RESULTS: The sentinel nodes were resected using the da Vinci® Si robot under guidance of DROP-IN gamma tracing and fluorescence imaging. The surgeon was able to independently maneuver the DROP-IN probe using the ProGrasp® forceps of the da Vinci® robot and distinguish sentinel nodes from background signal (such as the injection site). CONCLUSIONS: Overall the DROP-IN design proves to be a valuable tool for robot-assisted radioguided surgery approaches.


Assuntos
Laparoscopia/métodos , Neoplasias da Próstata/cirurgia , Procedimentos Cirúrgicos Robóticos/métodos , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único , Idoso , Humanos , Verde de Indocianina , Laparoscopia/instrumentação , Masculino , Pessoa de Meia-Idade , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Compostos Radiofarmacêuticos , Procedimentos Cirúrgicos Robóticos/instrumentação , Linfonodo Sentinela/cirurgia , Tecnécio
16.
Malar J ; 18(1): 155, 2019 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-31046772

RESUMO

BACKGROUND: The protective efficacy of the most promising malaria whole-parasite based vaccine candidates critically depends on the parasite's potential to migrate in the human host. Key components of the parasite motility machinery (e.g. adhesive proteins, actin/myosin-based motor, geometrical properties) have been identified, however the regulation of this machinery is an unknown process. METHODS: In vitro microscopic live imaging of parasites in different formulations was performed and analysed, with the quantitative analysis software SMOOTIn vitro, their motility; their adherence capacity, movement pattern and velocity during forward locomotion. RESULTS: SMOOTIn vitro enabled the detailed analysis of the regulation of the motility machinery of Plasmodium berghei in response to specific (macro)molecules in the formulation. Albumin acted as an essential supplement to induce parasite attachment and movement. Glucose, salts and other whole serum components further increased the attachment rate and regulated the velocity of the movement. CONCLUSIONS: Based on the findings can be concluded that a complex interplay of albumin, glucose and certain salts and amino acids regulates parasite motility. Insights in parasite motility regulation by supplements in solution potentially provide a way to optimize the whole-parasite malaria vaccine formulation.


Assuntos
Meios de Cultura/química , Locomoção/efeitos dos fármacos , Plasmodium berghei/efeitos dos fármacos , Esporozoítos/fisiologia , Albuminas/farmacologia , Animais , Culicidae/parasitologia , Meios de Cultura/farmacologia , Feminino , Glucose/farmacologia , Microscopia Intravital , Malária/parasitologia , Camundongos , Plasmodium berghei/fisiologia , Software
17.
J Urol ; 199(4): 1061-1068, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29174485

RESUMO

PURPOSE: Real-time visualization fluorescence imaging can guide surgeons during tissue resection. Unfortunately tissue induced signal attenuation limits the value of this technique to superficial applications. By positioning the fluorescence camera via a dedicated navigation setup we reasoned that the technology could be made compatible with deeper lesions, increasing its impact on clinical care. Such an impact would benefit from the ability to implement the navigation technology in different surgical settings. For that reason we evaluated whether a single fluorescence camera could be navigated toward targeted lesions during open and laparoscopic surgery. MATERIALS AND METHODS: A fluorescence camera with scopes available for open and laparoscopic procedures was integrated with a navigation platform. Lymph nodes identified on SPECT/CT (single photon emission computerized tomography/computerized tomography) or free-hand single photon emission computerized tomography acted as navigation targets and were displayed as augmented overlays in the fluorescence camera video feed. The accuracy of this setup was evaluated in a phantom study of 4 scans per single photon emission computerized tomography imaging modality. This was followed by 4 first in human translations into sentinel lymph node biopsy procedures for penile (open surgery) and prostate (laparoscopic surgery) cancer. RESULTS: Overall the phantom studies revealed a tool-target distance accuracy of 2.1 mm for SPECT/CT and 3.2 mm for freehand single photon emission computerized tomography, and an augmented reality registration accuracy of 1.1 and 2.2 mm, respectively. Subsequently open and laparoscopic navigation efforts were accurate enough to localize the fluorescence signals of the targeted tissues in vivo. CONCLUSIONS: The phantom and human studies performed suggested that the single navigation setup is applicable in various open and laparoscopic urological surgery applications. Further evaluation in larger patient groups with a greater variety of malignancies is recommended to strengthen these results.


Assuntos
Imageamento Tridimensional/métodos , Laparoscopia/métodos , Biópsia de Linfonodo Sentinela/métodos , Cirurgia Assistida por Computador/métodos , Procedimentos Cirúrgicos Urológicos Masculinos/métodos , Fluorescência , Humanos , Imageamento Tridimensional/instrumentação , Linfonodos/diagnóstico por imagem , Linfonodos/cirurgia , Masculino , Neoplasias Penianas/cirurgia , Imagens de Fantasmas , Neoplasias da Próstata/cirurgia , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/métodos
19.
Curr Opin Urol ; 28(2): 205-213, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29278582

RESUMO

PURPOSE OF REVIEW: To provide an overview of the developments made for virtual- and augmented-reality navigation procedures in urological interventions/surgery. RECENT FINDINGS: Navigation efforts have demonstrated potential in the field of urology by supporting guidance for various disorders. The navigation approaches differ between the individual indications, but seem interchangeable to a certain extent. An increasing number of pre- and intra-operative imaging modalities has been used to create detailed surgical roadmaps, namely: (cone-beam) computed tomography, MRI, ultrasound, and single-photon emission computed tomography. Registration of these surgical roadmaps with the real-life surgical view has occurred in different forms (e.g. electromagnetic, mechanical, vision, or near-infrared optical-based), whereby the combination of approaches was suggested to provide superior outcome. Soft-tissue deformations demand the use of confirmatory interventional (imaging) modalities. This has resulted in the introduction of new intraoperative modalities such as drop-in US, transurethral US, (drop-in) gamma probes and fluorescence cameras. These noninvasive modalities provide an alternative to invasive technologies that expose the patients to X-ray doses. Whereas some reports have indicated navigation setups provide equal or better results than conventional approaches, most trials have been performed in relatively small patient groups and clear follow-up data are missing. SUMMARY: The reported computer-assisted surgery research concepts provide a glimpse in to the future application of navigation technologies in the field of urology.


Assuntos
Cirurgia Assistida por Computador/métodos , Doenças Urológicas/cirurgia , Procedimentos Cirúrgicos Urológicos/métodos , Realidade Virtual , Diagnóstico por Imagem/métodos , Humanos , Cirurgia Assistida por Computador/instrumentação , Cirurgia Assistida por Computador/tendências , Procedimentos Cirúrgicos Urológicos/instrumentação , Procedimentos Cirúrgicos Urológicos/tendências
20.
Expert Rev Med Devices ; 21(5): 349-358, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38722051

RESUMO

INTRODUCTION: Surgery and biomedical imaging encompass a big share of the medical-device market. The ever-mounting demand for precision surgery has driven the integration of these two into the field of image-guided surgery. A key-question herein is how imaging modalities can guide the surgical decision-making process. Through performance-based design, chemists, engineers, and doctors need to build a bridge between imaging technologies and surgical challenges. AREAS-COVERED: This perspective article highlights the complementary nature between the technological design of an image-guidance modality and the type of procedure performed. The specific roles of the involved professionals, imaging technologies, and surgical indications are addressed. EXPERT-OPINION: Molecular-image-guided surgery has the potential to advance pre-, intra- and post-operative tissue characterization. To achieve this, surgeons need the access to well-designed indication-specific chemical-agents and detection modalities. Hereby, some technologies stimulate exploration ('go'), while others stimulate caution ('stop'). However, failing to adequately address the indication-specific needs rises the risk of incorrect tool employment and sub-optimal surgical performance. Therefore, besides the availability of new technologies, market growth is highly dependent on the practical nature and impact on real-life clinical care. While urology currently takes the lead in the widespread implementation of image-guidance technologies, the topic is generic and its popularity spreads rapidly within surgical oncology.


Assuntos
Cirurgia Assistida por Computador , Humanos , Cirurgia Assistida por Computador/instrumentação , Cirurgia Assistida por Computador/métodos , Diagnóstico por Imagem/métodos , Diagnóstico por Imagem/instrumentação , Medicina de Precisão/métodos , Medicina de Precisão/instrumentação , Equipamentos e Provisões
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa