Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Eur Spine J ; 31(4): 830-842, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34999945

RESUMO

BACKGROUND: Periprosthetic bone loss is a common observation following arthroplasty. Recognizing and understanding the nature of bone loss is vital as it determines the subsequent performance of the device and the overall outcome. Despite its significance, the term "bone loss" is often misused to describe inflammatory osteolysis, a complication with vastly different clinical outcomes and treatment plans. Therefore, the goal of this review was to report major findings related to vertebral radiographic bone changes around cervical disc replacements, mitigate discrepancies in clinical reports by introducing uniform terminology to the field, and establish a precedence that can be used to identify the important nuances between these distinct complications. METHODS: A systematic review of the literature was conducted following PRISMA guidelines, using the keywords "cervical," "disc replacement," "osteolysis," "bone loss," "radiograph," and "complications." A total of 23 articles met the inclusion criteria with the majority being retrospective or case reports. RESULTS: Fourteen studies reported periprosthetic osteolysis in a total of 46 patients with onset ranging from 15-96 months after the index procedure. Reported causes included: metal hypersensitivity, infection, mechanical failure, and wear debris. Osteolysis was generally progressive and led to reoperation. Nine articles reported non-inflammatory bone loss in 527 patients (52.5%), typically within 3-6 months following implantation. The reported causes included: micromotion, stress shielding, and interrupted blood supply. With one exception, bone loss was reported to be non-progressive and had no effect on clinical outcome measures. CONCLUSIONS: Non-progressive, early onset bone loss is a common finding after CDA and typically does not affect the reported short-term pain scores or lead to early revision. By contrast, osteolysis was less common, presenting more than a year post-operative and often accompanied by additional complications, leading to revision surgery. A greater understanding of the clinical significance is limited by the lack of long-term studies, inconsistent terminology, and infrequent use of histology and explant analyses. Uniform reporting and adoption of consistent terminology can mitigate some of these limitations. Executing these actionable items is critical to assess device performance and the risk of revision. LEVEL OF EVIDENCE IV: Diagnostic: individual cross-sectional studies with consistently applied reference standard and blinding.


Assuntos
Osteólise , Artroplastia/efeitos adversos , Estudos Transversais , Humanos , Osteólise/diagnóstico por imagem , Osteólise/etiologia , Osteólise/cirurgia , Falha de Prótese , Reoperação/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento
2.
JOR Spine ; 7(1): e1285, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38222806

RESUMO

Purpose: Composite models have become commonplace for the assessment of fixation and stability of total joint replacements; however, there are no comparable models for the cervical spine to evaluate fixation. The goal of this study was to create the framework for a tunable non-homogeneous model of cervical vertebral body by identifying the relationships between strength, in-fill density, and lattice structure and creating a final architectural framework for specific strengths to be applied to the model. Methods: The range of material properties for cervical spine were identified from literature. Using additive manufacturing software, rectangular prints with three lattice structures, gyroid, triangle, zig-zag, and a range of in-fill densities were 3D-printed. The compressive and shear strengths for all combinations were calculated in the axial and coronal planes. Eleven unique vertebral regions were selected to represent the distribution of density. Each bone density was converted to strength and subsequently correlated to the lattice structure and in-fill density with the desired material properties. Finally, a complete cervical vertebra model was 3D-printed to ensure sufficient print quality. Results: Materials testing identified a relationship between in-fill densities and strength for all lattice structures. The axial compressive strength of the gyroid specimens ranged from 1.5 MPa at 10% infill to 31.3 MPa at 100% infill and the triangle structure ranged from 2.7 MPa at 10% infill to 58.4 MPa at 100% infill. Based on these results, a cervical vertebra model was created utilizing cervical cancellous strength values and the corresponding in-fill density and lattice structure combination. This model was then printed with 11 different in-fill densities ranging from 33% gyroid to 84% triangle to ensure successful integration of the non-homogeneous in-fill densities and lattice structures. Conclusions: The findings from this study introduced a framework for using additive manufacturing to create a tunable, customizable biomimetic model of a cervical vertebra.

3.
J Biomed Mater Res B Appl Biomater ; 111(9): 1653-1663, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37191359

RESUMO

Total disc replacements utilize textured coatings to maximize bony ongrowth. However, the contribution of direct bony attachment to overall fixation for total disc replacements has not been reported. The goal of the present study was to document the extent of bony attachment to the surfaces of two clinically functional total disc replacements that were securely fixed at the time of revision. Two metal-and-polymeric disc replacements, one cervical and one lumbar, were evaluated following surgical retrieval. The cervical device was retrieved at 8 months and the lumbar device at 28 months post-operative. Both devices were reported well-fixed at the time of removal, with large bone masses attached to one endplate of each device. Visual inspections, non-destructive gravimetric measurements, and surface metrology were performed to assess fixation. These inspections suggested that both devices had been fixed at the time of removal with little in vivo mechanical damage, as surgical extraction damage was noted on both devices and provided imaging showed a lack of device migration. Devices were then embedded and sectioned to evaluate the bone-implant interface. High resolution photographs and contact microradiographs were taken to assess bony attachment. In contrast to initial analysis, these images revealed radiolucent gaps between the endplates and bone masses. Little direct contact between the bone and endplate surface was identified and the original surgical cuts were still visible. Both devices were clinically fixed at the time of removal and neither had complications associated with loosening. However, osseointegration was minimal in one of the devices and altogether absent from the other. The findings of the present study suggest that other factors may influence overall clinical fixation such as the surgical preparation of the vertebral bone or the surface roughness of the treated endplates. Despite the limitations of the present study, this information is unique to the current total disc replacement literature and the ongrowth and fixation of devices should be considered as a topic for future investigation.


Assuntos
Disco Intervertebral , Substituição Total de Disco , Disco Intervertebral/cirurgia , Osseointegração , Metais
4.
OTA Int ; 6(3): e278, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37497388

RESUMO

Objectives: Implant prominence after ulnar fracture fixation may be mitigated by the use of lower profile plates. The biomechanical strength and stability of 2.7-mm and 3.5-mm locking compression plates for fixation were compared. Methods: Two fracture conditions, transverse (N = 10) and oblique (N = 10), were evaluated in an in vitro study. Half of the specimens for each condition were fixed with 2.7-mm plates and the other half with 3.5-mm plates, all fixed with conventional dynamic compression mechanisms. Specimens were loaded under ±2 Nm of cyclic axial torsion, then under 10 Nm of cyclic cantilever bending, and bending to failure. Interfragmentary motion and strain were analyzed to determine construct stability as a function of fracture pattern and plate size. Results: Interfragmentary motion was significantly larger in all constructs fixed with 2.7-mm plates, compared with 3.5-mm plates (P < 0.01). The 2.7-mm constructs with transverse fractures had the greatest motion, ranging between 5° and 10° under axial rotation and 5.0-6.0 mm under bending. Motions were the lowest for 3.5-mm constructs with oblique fractures, ranging between 3.2 and 4.2 mm under bending and 2°-3.5° for axial rotation. For oblique fractures, the bending moment at ultimate failure was 31.4 ± 3.6 Nm for the 2.7-mm constructs and 10.0 ± 1.9 Nm for 3.5-mm constructs (P < 0.01). Similarly, for transverse fractures, the bending moment was 17.9 ± 4.0 Nm for the 2.7-mm constructs and 9.7 ± 1.3 Nm for the 3.5-mm constructs (P < 0.01). Conclusions: Although 3.5-mm plates were more effective at reducing fracture motion, they were consistently associated with refracture at the distal-most screw hole under load to failure. By contrast, 2.7-mm plates plastically deformed despite excessive loads, potentially avoiding a subsequent fracture. Level of Evidence: Level V.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa