Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Anal Chem ; 95(48): 17426-17437, 2023 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-37972233

RESUMO

UV-vis spectrophotometry and spectrofluorometry are indispensable tools in education, research, and industrial process controls with widespread applications in nanoscience encompassing diverse nanomaterials and fields. Nevertheless, the prevailing spectroscopic interpretations and analyses often exhibit ambiguity and errors, particularly evident in the nanoscience literature. This analytical chemistry Perspective focuses on fostering evidence-based data interpretation in experimental studies of materials' UV-vis absorption, scattering, and fluorescence properties. We begin by outlining common issues observed in UV-vis and fluorescence analysis. Subsequently, we provide a summary of recent advances in commercial UV-vis spectrophotometric and spectrofluorometric instruments, emphasizing their potential to enhance scientific rigor in UV-vis and fluorescence analysis. Furthermore, we propose potential avenues for future developments in spectroscopic instrumentation and measurement strategies, aiming to further augment the utility of optical spectroscopy in nano research for samples where optical complexity surpasses existing tools. Through a targeted focus on the critical issues related to UV-vis and fluorescence properties of nanomaterials, this Perspective can serve as a valuable resource for researchers, educators, and practitioners.

2.
Anal Chem ; 95(27): 10279-10288, 2023 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-37382879

RESUMO

Cascading optical processes involve sequential photon-matter interactions triggered by the same individual excitation photons. Parts I and II of this series explored cascading optical processes in scattering-only solutions (Part I) and solutions with light scatterers and absorbers but no emitters (Part II). The current work (Part III) focuses on the effects of cascading optical processes on spectroscopic measurements of fluorescent samples. Four types of samples were examined: (1) eosin Y (EOY), an absorber and emitter; (2) EOY mixed with plain polystyrene nanoparticles (PSNPs), which are pure scatterers; (3) EOY mixed with dyed PSNPs, which scatter and absorb light but do not emit; and (4) fluorescent PSNPs that are simultaneous light absorbers, scatterers, and emitters. Interference from both forward scattered and emitted photons can cause nonlinearity and spectral distortion in UV-vis extinction measurements. Sample absorption by nonfluorogenic chromophores reduces fluorescence intensity, while the effect of scattering on fluorophore fluorescence is complicated by several competing factors. A revised first-principles model is developed for correlating the experimental fluorescence intensity with the sample absorbance in solutions containing both scatterers and absorbers. The optical properties of fluorescent PSNPs of three different sizes were systematically investigated by using integrating-sphere-assisted resonance synchronous spectroscopy, linearly polarized resonance synchronous spectroscopy, UV-vis, and fluorescence spectroscopy. The insights and methodology provided in this work should help improve the reliability of spectroscopic analyses of fluorescent samples, where the interplay among light absorption, scattering, and emission can be complex.

3.
Anal Chem ; 2023 Jan 04.
Artigo em Inglês | MEDLINE | ID: mdl-36598877

RESUMO

Light scattering is a universal matter property that is especially prominent in nanoscale or larger materials. However, the effects of scattering-based cascading optical processes on experimental quantification of sample absorption, scattering, and emission intensities, as well as scattering and emission depolarization, have not been adequately addressed. Using a series of polystyrene nanoparticles (PSNPs) of different sizes as model analytes, we present a computational and experimental study on the effects of cascading light scattering on experimental quantification of NP scattering activities (scattering cross-section or molar coefficient), intensity, and depolarization. Part II and Part III of this series of companion articles explore the effects of cascading optical processes on sample absorption and fluorescence measurements, respectively. A general theoretical model is developed on how forward scattered light complicates the general applicability of Beer's law to the experimental UV-vis spectrum of scattering samples. The correlation between the scattering intensity and PSNP concentration is highly complicated with no robust linearity even when the scatterers' concentration is very low. Such complexity arises from the combination of concentration-dependence of light scattering depolarization and the scattering inner filter effects (IFEs). Scattering depolarization increases with the PSNP scattering extinction (thereby, its concentration) but can never reach unity (isotropic) due to the polarization dependence of the scattering IFE. The insights from this study are important for understanding the strengths and limitations of various scattering-based techniques for material characterization including nanoparticle quantification. They are also foundational for quantitative mechanistic understanding on the effects of light scattering on sample absorption and fluorescence measurements.

4.
Anal Chem ; 95(9): 4461-4469, 2023 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-36787490

RESUMO

In Part I of the three companion articles, we reported the effects of light scattering on experimental quantification of scattering extinction, intensity, and depolarization in solutions that contain only scatterers with no significant absorption and photoluminescence activities. The present work (Part II) studies the effects of light scattering and absorption on a series of optical spectroscopic measurements done on samples that contain both absorbers and scatterers, but not emitters. The experimental UV-vis spectrum is the sum of the sample absorption and scattering extinction spectra. However, the upper limit of the experimental Beer's-law-abiding extinction can be limited prematurely by the interference of forward scattered light. Light absorption reduces not only the sample scattering intensity but also the scattering depolarization. The impact of scattering on sample light absorption is complicated, depending on whether the absorption of scattered light is taken into consideration. Scattering reduces light absorption along the optical path length from the excitation source to the UV-vis detector. However, the absorption of the scattered light can be adequate to compensate the reduced light absorption along such optical path, making the impacts of light scattering on the sample total light absorption negligibly small (<10%). The latter finding constitutes a critical validation of the integrating-sphere-assisted resonance synchronous spectroscopic method for experimental quantification of absorption and scattering contribution to the sample UV-vis extinction spectra. The techniques and general guidelines provided in this work should help improve the reliability of optical spectroscopic characterization of nanoscale or larger materials, many of which are simultaneous absorbers and scatterers. The insights from this work are foundational for Part III of this series of work, which is on the cascading optical processes on spectroscopic measurements of fluorescent samples.

5.
Anal Chem ; 94(33): 11610-11618, 2022 08 23.
Artigo em Inglês | MEDLINE | ID: mdl-35960824

RESUMO

Integrating spheres (IS) have been used extensively for the characterization of light absorption in turbid samples. However, converting the IS-based sample absorption coefficient to the UV-vis absorbance quantified with a double-beam UV-vis spectrophotometer is challenging. Herein, we report an integrating-sphere-assisted resonance synchronous (ISARS) spectroscopy method performed with conventional spectrofluorometers equipped with an integrating-sphere accessory. Mathematical models and experimental procedures for quantifying the sample, solvent, and instrument-baseline ISARS intensity spectra were provided. A three-parameter analytical model has been developed for correlating the ISARS-based UV-vis absorbance and the absorbance measured with double-beam instruments. This ISARS method enables the quantitative separation of light absorption and scattering contribution to the sample UV-vis extinction spectrum measured with double-beam UV-vis spectrophotometers. Example applications of this ISARS technique are demonstrated with a series of representative samples differing significantly in their optical complexities, from approximately pure absorbers, pure scatterers, to simultaneous light absorbers, scatterers, and emitters under resonance excitation and detection conditions.


Assuntos
Análise Espectral , Espectrofotometria/métodos
6.
Anal Chem ; 94(19): 7123-7131, 2022 05 17.
Artigo em Inglês | MEDLINE | ID: mdl-35507917

RESUMO

The popular textbook and literature model I(λx,λm) = K(λx,λm)(1-10-Ax) or its variants for correlating the sample absorption and fluorescence often fails even for the simplest samples where the fluorophore is the only light absorber. Reported is a first-principle model I(λx,λm) = K(λx,λm)Ax,f10-(Ax,sdx+Am,sdm) for correlating the sample fluorescence measured with a conventional spectrofluorometer and its UV-vis absorbance quantified with a conventional UV-vis spectrophotometer. This model can be simplified or expanded for a variety of fluorescence analyses. First, it enables curve-fitting fluorescence intensity as a function of the fluorophore or sample absorbance over a sample concentration range impossible with existing models. Second, it provides the theoretical foundation for an inner-filter-effect (IFE)-correction method developed earlier and explains mathematically the linearity between the IFE-corrected fluorescence and the fluorophore concentration or absorbance. Third, this model can be expanded for quantitative mechanistic studies of fluorescence intensity variations triggered by stimuli treatments. One demonstrated example is to quantify temperature effects on the emission-wavelength-specific and total fluorescence quantum yield of anthracene. We expect that this first-principle model will be broadly adopted for both student education that promotes evidence-based learning and a variety of fluorescence applications where disentangling sample absorption and emission are critical for reliable data analysis.


Assuntos
Corantes Fluorescentes , Humanos , Espectrometria de Fluorescência/métodos
7.
ACS Meas Sci Au ; 3(1): 10-20, 2023 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-36817009

RESUMO

Quantification of the temperature effects on the optical properties of photoluminescent (PL) materials is important for a fundamental understanding of both materials optical processes and rational PL materials design and applications. However, existing techniques for studying the temperature effects are limited in their information content. Reported herein is a temperature-dependent total photoluminescence (TPL) spectroscopy technique for probing the temperature dependence of materials optical properties. When used in combination with UV-vis measurements, this TPL method enables experimental quantification of temperature effects on fluorophore fluorescence intensity and quantum yield at any combination of excitation and detection wavelengths, including the fluorophore Stokes-shifted and anti-Stokes-shifted fluorescence. All model polyaromatic hydrocarbon (PAH) and xanthene fluorophores exhibited a strong excitation- and emission-wavelength dependence in their temperature effects. However, the heavy-atom effects used for explaining the strong temperature dependence of brominated anthracenes are not operative with xanthene fluorophores that have heavy atom substitutions. The insights from TPL measurements are important not only for enhancing the fundamental understandings of the materials photophysical properties but also for rational measurement design for applications where the temperature sensitivity of the fluorophore fluorescence is critical. An example application is demonstrated for developing a sensitive and robust ratiometric fluorescence thermometric method for in situ real-time monitoring of sample temperatures inside a fluorescence cuvette placed in a temperature-controlled sample holder.

8.
ACS Appl Mater Interfaces ; 14(15): 17560-17569, 2022 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-35380793

RESUMO

Polydopamine (PDA) is a unique bioinspired synthetic polymer that integrates broadband light absorption, efficient photothermal transduction, and versatile surface-adhesion functions in a single material entity. Here, we utilize colloidal PDA beads in the submicron particle size regime as an easily processable and photothermally active support for sub-10 nm Pd nanocatalysts to construct a multifunctional material system that allows us to kinetically boost thermal catalytic reactions through visible and near-infrared light illuminations. Choosing the Pd-catalyzed nitrophenol reduction by ammonium formate as a model transfer hydrogenation reaction exhibiting temperature-dependent reaction rates, we demonstrate that interfacial molecule-transforming processes on metal nanocatalyst surfaces can be kinetically modulated by harnessing the thermal energy produced through photothermal transduction in the PDA supports.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa