1.
Magn Reson Med ; 90(3): 1130-1136, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37222226

RESUMO

The British and Irish Chapter of the International Society for Magnetic Resonance in Medicine (BIC-ISMRM) held a workshop entitled "Steps on the path to clinical translation" in Cardiff, UK, on 7th September 2022. The aim of the workshop was to promote discussion within the MR community about the problems and potential solutions for translating quantitative MR (qMR) imaging and spectroscopic biomarkers into clinical application and drug studies. Invited speakers presented the perspectives of radiologists, radiographers, clinical physicists, vendors, imaging Contract/Clinical Research Organizations (CROs), open science networks, metrologists, imaging networks, and those developing consensus methods. A round-table discussion was held in which workshop participants discussed a range of questions pertinent to clinical translation of qMR imaging and spectroscopic biomarkers. Each group summarized their findings via three main conclusions and three further questions. These questions were used as the basis of an online survey of the broader UK MR community.


Assuntos
Imageamento por Ressonância Magnética , Humanos , Espectroscopia de Ressonância Magnética , Biomarcadores
2.
J Magn Reson Imaging ; 56(4): 1042-1052, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35224803

RESUMO

BACKGROUND: Three-dimensional variable flip angle (VFA) methods are commonly used for T1 mapping of the liver, but there is no data on the accuracy, repeatability, and reproducibility of this technique in this organ in a multivendor setting. PURPOSE: To measure bias, repeatability, and reproducibility of VFA T1 mapping in the liver. STUDY TYPE: Prospective observational. POPULATION: Eight healthy volunteers, four women, with no known liver disease. FIELD STRENGTH/SEQUENCE: 1.5-T and 3.0-T; three-dimensional steady-state spoiled gradient echo with VFAs; Look-Locker. ASSESSMENT: Traveling volunteers were scanned twice each (30 minutes to 3 months apart) on six MRI scanners from three vendors (GE Healthcare, Philips Medical Systems, and Siemens Healthineers) at two field strengths. The maximum period between the first and last scans among all volunteers was 9 months. Volunteers were instructed to abstain from alcohol intake for at least 72 hours prior to each scan and avoid high cholesterol foods on the day of the scan. STATISTICAL TESTS: Repeated measures ANOVA, Student t-test, Levene's test of variances, and 95% significance level. The percent error relative to literature liver T1 in healthy volunteers was used to assess bias. The relative error (RE) due to intrascanner and interscanner variation in T1 measurements was used to assess repeatability and reproducibility. RESULTS: The 95% confidence interval (CI) on the mean bias and mean repeatability RE of VFA T1 in the healthy liver was 34 ± 6% and 10 ± 3%, respectively. The 95% CI on the mean reproducibility RE at 1.5 T and 3.0 T was 29 ± 7% and 25 ± 4%, respectively. DATA CONCLUSION: Bias, repeatability, and reproducibility of VFA T1 mapping in the liver in a multivendor setting are similar to those reported for breast, prostate, and brain. LEVEL OF EVIDENCE: 1 TECHNICAL EFFICACY STAGE: 1.


Assuntos
Encéfalo , Imageamento por Ressonância Magnética , Encéfalo/diagnóstico por imagem , Feminino , Humanos , Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Masculino , Imagens de Fantasmas , Próstata , Reprodutibilidade dos Testes
3.
Eur Radiol ; 31(8): 5746-5758, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33591383

RESUMO

OBJECTIVES: Evaluate test-retest repeatability, ability to discriminate between osteoarthritic and healthy participants, and sensitivity to change over 6 months, of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) biomarkers in knee OA. METHODS: Fourteen individuals aged 40-60 with mild-moderate knee OA and 6 age-matched healthy volunteers (HV) underwent DCE-MRI at 3 T at baseline, 1 month and 6 months. Voxelwise pharmacokinetic modelling of dynamic data was used to calculate DCE-MRI biomarkers including Ktrans and IAUC60. Median DCE-MRI biomarker values were extracted for each participant at each study visit. Synovial segmentation was performed using both manual and semiautomatic methods with calculation of an additional biomarker, the volume of enhancing pannus (VEP). Test-retest repeatability was assessed using intraclass correlation coefficients (ICC). Smallest detectable differences (SDDs) were calculated from test-retest data. Discrimination between OA and HV was assessed via calculation of between-group standardised mean differences (SMD). Responsiveness was assessed via the number of OA participants with changes greater than the SDD at 6 months. RESULTS: Ktrans demonstrated the best test-retest repeatability (Ktrans/IAUC60/VEP ICCs 0.90/0.84/0.40, SDDs as % of OA mean 33/71/76%), discrimination between OA and HV (SMDs 0.94/0.54/0.50) and responsiveness (5/1/1 out of 12 OA participants with 6-month change > SDD) when compared to IAUC60 and VEP. Biomarkers derived from semiautomatic segmentation outperformed those derived from manual segmentation across all domains. CONCLUSIONS: Ktrans demonstrated the best repeatability, discrimination and sensitivity to change suggesting that it is the optimal DCE-MRI biomarker for use in experimental medicine studies. KEY POINTS: • Dynamic contrast-enhanced MRI (DCE-MRI) provides quantitative measures of synovitis in knee osteoarthritis which may permit early assessment of efficacy in experimental medicine studies. • This prospective observational study compared DCE-MRI biomarkers across domains relevant to experimental medicine: test-retest repeatability, discriminative validity and sensitivity to change. • The DCE-MRI biomarker Ktrans demonstrated the best performance across all three domains, suggesting that it is the optimal biomarker for use in future interventional studies.


Assuntos
Osteoartrite do Joelho , Sinovite , Meios de Contraste , Humanos , Lactente , Articulação do Joelho , Imageamento por Ressonância Magnética , Osteoartrite do Joelho/diagnóstico por imagem , Estudos Prospectivos , Sinovite/diagnóstico por imagem
4.
Magn Reson Med ; 84(4): 2147-2160, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32162395

RESUMO

PURPOSE: To develop a fully automated vessel wall (VW) analysis workflow (fully automated and robust analysis technique for popliteal artery evaluation, FRAPPE) on the popliteal artery in standardized knee MR images. METHODS: Popliteal artery locations were detected from each MR slice by a deep neural network model and connected into a 3D artery centerline. Vessel wall regions around the centerline were then segmented using another neural network model for segmentation in polar coordinate system. Contours from vessel wall segmentations were used for vascular feature calculation, such as mean wall thickness and wall area. A transfer learning and active learning framework was applied in training the localization and segmentation neural network models to maintain accuracy while reducing manual annotations. This new popliteal artery analysis technique (FRAPPE) was validated against manual segmentation qualitatively and quantitatively in a series of 225 cases from the Osteoarthritis Initiative (OAI) dataset. RESULTS: FRAPPE demonstrated high accuracy and robustness in locating popliteal arteries, segmenting artery walls, and quantifying arterial features. Qualitative evaluations showed 1.2% of slices had noticeable major errors, including segmenting the wrong target and irregular vessel wall contours. The mean Dice similarity coefficient with manual segmentation was 0.79, which is comparable to inter-rater variations. Repeatability evaluations show most of the vascular features have good to excellent repeatability from repeated scans of same subjects, with intra-class coefficient ranging from 0.80 to 0.98. CONCLUSION: This technique can be used in large population-based studies, such as OAI, to efficiently assess the burden of atherosclerosis from routine MR knee scans.


Assuntos
Imageamento por Ressonância Magnética , Artéria Poplítea , Humanos , Redes Neurais de Computação , Artéria Poplítea/diagnóstico por imagem
5.
Arterioscler Thromb Vasc Biol ; 39(6): 1018-1025, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-31070477

RESUMO

Atherosclerotic cardiovascular disease remains a worldwide epidemic and one of the leading causes of death nowadays. Vessel wall imaging can be used to understand the development and progression of atherosclerosis, but it is rarely done because of the high cost. We recently identified the Osteoarthritis Initiative, a large prospective cohort study of knee osteoarthritis, which might serve as a valuable source for atherosclerosis research with its serial knee magnetic resonance imaging data. We have found that these images are suitable for vessel wall image analysis of the lower extremity arteries. Here, we will introduce the Osteoarthritis Initiative data set and explain why it could be used for cardiovascular research purposes. Also, we will briefly comment on peripheral artery atherosclerosis as it is covered in the Osteoarthritis Initiative image data set and review the use of vessel wall imaging for studying atherosclerosis. We think data mining of imaging studies, not originally designed on cardiovascular research, can not only maximize the value of the imaging data set but also boost our understanding of atherosclerosis.


Assuntos
Aterosclerose/diagnóstico por imagem , Aterosclerose/patologia , Angiografia por Ressonância Magnética , Osteoartrite do Joelho/diagnóstico por imagem , Doença Arterial Periférica/diagnóstico por imagem , Idoso , Aterosclerose/epidemiologia , Compreensão , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/epidemiologia , Bases de Dados Factuais , Progressão da Doença , Humanos , Imageamento por Ressonância Magnética/métodos , Pessoa de Meia-Idade , Osteoartrite do Joelho/patologia , Doença Arterial Periférica/epidemiologia , Placa Aterosclerótica/patologia , Estudos Prospectivos
7.
J Magn Reson Imaging ; 50(3): 771-778, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-30756434

RESUMO

BACKGROUND: Imaging biomarkers, such as the T1 relaxation time of the myocardium using MRI, can be valuable in cardiac medicine if they are properly validated. Consensus statements recommend that for myocardial T1 , each investigator should establish a reference range. PURPOSE: To describe a statistically valid method for determining and reporting the reference range in each center, which simultaneously minimizes the twin risks of undersampling, leading to a uselessly uncertain range, and oversampling, which exposes volunteers to unnecessary scanning and wastes resources. STUDY TYPE: Cohort. POPULATION: In all, 278 normal human subjects without cardiac disease from two cardiac MR centers. FIELD STRENGTH/SEQUENCE: 1.5 T and 3 T; Modified Look-Locker Inversion recovery sequence. ASSESSMENT: The T1 relaxation time was estimated from multiple samples of tissue magnetization after inversion. A valid method for calculating a reference range was used. STATISTICAL TESTS: Shapiro-Wilk test for normality; Tukey robust approach for identification of outliers; reference range calculation with confidence intervals. RESULTS: Reference ranges for measurement of myocardial T1 were calculated, with confidence intervals, enabling comparison with clinically important differences. At 3 T: 1129 to 1301 msec at site 1 (n = 21) and 1160 to 1309 msec at site 2 (n = 59), and at 1.5 T at site 2: 933 to 1020 msec (male, n = 130) and 965 to 1054 msec (female, n = 68). The 3 T reference range from site 1 was successfully benchmarked against the 3 T reference range at site 2. DATA CONCLUSION: Myocardial T1 reference ranges can be properly characterized, enabling clinical comparison to a valid reference range with known confidence intervals, using methodology similar to that described in this report. LEVEL OF EVIDENCE: 3 Technical Efficacy Stage: 3 J. Magn. Reson. Imaging 2019;50:771-778.


Assuntos
Coração/anatomia & histologia , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Biomarcadores , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valores de Referência , Reprodutibilidade dos Testes
8.
Radiology ; 288(3): 739-747, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29869970

RESUMO

Purpose To cross-validate T1-weighted oxygen-enhanced (OE) MRI measurements of tumor hypoxia with intrinsic susceptibility MRI measurements and to demonstrate the feasibility of translation of the technique for patients. Materials and Methods Preclinical studies in nine 786-0-R renal cell carcinoma (RCC) xenografts and prospective clinical studies in eight patients with RCC were performed. Longitudinal relaxation rate changes (∆R1) after 100% oxygen inhalation were quantified, reflecting the paramagnetic effect on tissue protons because of the presence of molecular oxygen. Native transverse relaxation rate (R2*) and oxygen-induced R2* change (∆R2*) were measured, reflecting presence of deoxygenated hemoglobin molecules. Median and voxel-wise values of ∆R1 were compared with values of R2* and ∆R2*. Tumor regions with dynamic contrast agent-enhanced MRI perfusion, refractory to signal change at OE MRI (referred to as perfused Oxy-R), were distinguished from perfused oxygen-enhancing (perfused Oxy-E) and nonperfused regions. R2* and ∆R2* values in each tumor subregion were compared by using one-way analysis of variance. Results Tumor-wise and voxel-wise ∆R1 and ∆R2* comparisons did not show correlative relationships. In xenografts, parcellation analysis revealed that perfused Oxy-R regions had faster native R2* (102.4 sec-1 vs 81.7 sec-1) and greater negative ∆R2* (-22.9 sec-1 vs -5.4 sec-1), compared with perfused Oxy-E and nonperfused subregions (all P < .001), respectively. Similar findings were present in human tumors (P < .001). Further, perfused Oxy-R helped identify tumor hypoxia, measured at pathologic analysis, in both xenografts (P = .002) and human tumors (P = .003). Conclusion Intrinsic susceptibility biomarkers provide cross validation of the OE MRI biomarker perfused Oxy-R. Consistent relationship to pathologic analyses was found in xenografts and human tumors, demonstrating biomarker translation. Published under a CC BY 4.0 license. Online supplemental material is available for this article.


Assuntos
Carcinoma de Células Renais/fisiopatologia , Hipóxia/fisiopatologia , Aumento da Imagem/métodos , Neoplasias Renais/fisiopatologia , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Animais , Biomarcadores , Carcinoma de Células Renais/complicações , Carcinoma de Células Renais/diagnóstico por imagem , Modelos Animais de Doenças , Estudos de Viabilidade , Feminino , Humanos , Hipóxia/complicações , Hipóxia/diagnóstico por imagem , Rim/diagnóstico por imagem , Rim/patologia , Rim/fisiopatologia , Neoplasias Renais/complicações , Neoplasias Renais/diagnóstico por imagem , Masculino , Camundongos , Pessoa de Meia-Idade , Oxigênio , Estudos Prospectivos , Reprodutibilidade dos Testes
10.
Eur Radiol ; 27(11): 4552-4562, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28396997

RESUMO

PURPOSE: To determine the test-retest repeatability of Apparent Diffusion Coefficient (ADC) measurements across institutions and MRI vendors, plus investigate the effect of post-processing methodology on measurement precision. METHODS: Thirty malignant lung lesions >2 cm in size (23 patients) were scanned on two occasions, using echo-planar-Diffusion-Weighted (DW)-MRI to derive whole-tumour ADC (b = 100, 500 and 800smm-2). Scanning was performed at 4 institutions (3 MRI vendors). Whole-tumour volumes-of-interest were copied from first visit onto second visit images and from one post-processing platform to an open-source platform, to assess ADC repeatability and cross-platform reproducibility. RESULTS: Whole-tumour ADC values ranged from 0.66-1.94x10-3mm2s-1 (mean = 1.14). Within-patient coefficient-of-variation (wCV) was 7.1% (95% CI 5.7-9.6%), limits-of-agreement (LoA) -18.0 to 21.9%. Lesions >3 cm had improved repeatability: wCV 3.9% (95% CI 2.9-5.9%); and LoA -10.2 to 11.4%. Variability for lesions <3 cm was 2.46 times higher. ADC reproducibility across different post-processing platforms was excellent: Pearson's R2 = 0.99; CoV 2.8% (95% CI 2.3-3.4%); and LoA -7.4 to 8.0%. CONCLUSION: A free-breathing DW-MRI protocol for imaging malignant lung tumours achieved satisfactory within-patient repeatability and was robust to changes in post-processing software, justifying its use in multi-centre trials. For response evaluation in individual patients, a change in ADC >21.9% will reflect treatment-related change. KEY POINTS: • In lung cancer, free-breathing DWI-MRI produces acceptable images with evaluable ADC measurement. • ADC repeatability coefficient-of-variation is 7.1% for lung tumours >2 cm. • ADC repeatability coefficient-of-variation is 3.9% for lung tumours >3 cm. • ADC measurement precision is unaffected by the post-processing software used. • In multicentre trials, 22% increase in ADC indicates positive treatment response.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Neoplasias Pulmonares/patologia , Estadiamento de Neoplasias/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Curva ROC , Reprodutibilidade dos Testes , Carga Tumoral
11.
Eur Radiol ; 27(9): 3662-3668, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28116513

RESUMO

OBJECTIVES: To determine the repeatability and response to therapy of dynamic contrast-enhanced (DCE) MRI biomarkers of synovitis in the hand and wrist of rheumatoid arthritis (RA) patients, and in particular the performance of the transfer constant K trans , in a multicentre trial setting. METHODS: DCE-MRI and RA MRI scoring (RAMRIS) were performed with meticulous standardisation at baseline and 6 and 24 weeks in a substudy of fostamatinib monotherapy in reducing synovitis compared with placebo or adalimumab. Analysis employed statistical shape modelling to avoid biased regions-of-interest, kinetic modelling and heuristic analyses. Repeatability was also evaluated. RESULTS: At early study termination, DCE-MRI data had been acquired from 58 patients in 19 imaging centres. K trans intra-subject coefficient of variation (N = 14) was 30%. K trans change demonstrated inferiority of fostamatinib (N = 11) relative to adalimumab (N = 10) after 6 weeks (treatment ratio = 1.92, p = 0.003), and failed to distinguish fostamatinib from placebo (N = 10, p = 0.79). RAMRIS showed superiority of fostamatinib relative to placebo at 6 weeks (p = 0.023), and did not distinguish fostamatinib from adalimumab at either 6 (p = 0.175) or 24 (p = 0.230) weeks. CONCLUSION: This demonstrated repeatability of K trans and its ability to distinguish treatment groups show that DCE-MRI biomarkers are suitable for use in multicentre RA trials. KEY POINTS: • DCE-MRI biomarkers are feasible in large multicentre studies of joint inflammation. • DCE-MRI K trans showed fostamatinib inferior to adalimumab after 6 weeks. • K trans repeatability coefficient of variation was 30% multicentre.


Assuntos
Adalimumab/uso terapêutico , Artrite Reumatoide/tratamento farmacológico , Imageamento por Ressonância Magnética/métodos , Oxazinas/uso terapêutico , Inibidores de Proteínas Quinases/uso terapêutico , Piridinas/uso terapêutico , Adulto , Idoso , Aminopiridinas , Artrite Reumatoide/diagnóstico por imagem , Artrite Reumatoide/metabolismo , Biomarcadores/análise , Feminino , Mãos/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Morfolinas , Pirimidinas , Reprodutibilidade dos Testes , Articulação do Punho/diagnóstico por imagem
12.
Clin Exp Rheumatol ; 35(6): 954-958, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28850028

RESUMO

OBJECTIVES: To investigate the association of novel non-contrast MRI biomarkers with standard measurements of renal function and renal disease activity in lupus. METHODS: A pilot study of lupus nephritis (LN) and lupus non-nephritis (LNN) patients, and healthy volunteers (HV), was undertaken. Multi-modal renal MRI was performed including sequences for arterial spin labelling (ASL) measuring blood flow, diffusion tensor imaging (DTI), measuring microstructural disruption, and effective transverse relaxation time (T2*) which is a biomarker of micro-haemorrhage. MRI measurements were compared with urinary protein creatinine ratio (uPCR) and estimated glomerular filtration rate (eGFR) measurements in the whole study population, then differences in imaging measurements between the groups were explored. RESULTS: 21 patients (6 LN, 8 LNN and 7 HV) completed the study, although ASL data were not available in 4 subjects. In the whole cohort, eGFR correlated significantly with the apparent diffusion coefficient measurement from DTI in the medulla (r=0.47, p=0.03). uPCR correlated strongly with the fractional anisotropy (FA) DTI measurement in the cortex and moderately with T2* measurements (rho=-0.71, p<0.001 and rho=-0.53, p=0.013, respectively). Delayed blood flow to the medulla was found in LN subjects and there was a trend towards lower FA values in the cortex, suggesting micro-structural disruption (p=0.04 and p=0.07, respectively). CONCLUSIONS: This preliminary study demonstrates that non-contrast renal MRI biomarkers are associated with standard measures of disease activity in lupus. The potential utility of these non-invasive biomarkers warrants further investigation, as there is an unmet need for reliable biomarkers of disease activity in lupus nephritis.


Assuntos
Nefrite Lúpica/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Adulto , Biomarcadores , Estudos de Coortes , Creatinina/urina , Imagem de Tensor de Difusão , Feminino , Taxa de Filtração Glomerular , Humanos , Rim/irrigação sanguínea , Rim/ultraestrutura , Nefrite Lúpica/fisiopatologia , Masculino , Projetos Piloto
13.
COPD ; 13(2): 153-9, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26488310

RESUMO

Magnetic resonance imaging (MRI) may provide attractive biomarkers for assessment of pulmonary disease in clinical trials as it is free from ionizing radiation, minimally invasive and allows regional information. The aim of this study was to characterize lung MRI T1 relaxation time as a biomarker of chronic obstructive pulmonary disease (COPD); and specifically its relationship to smoking history, computed tomography (CT), and pulmonary function test (PFT) measurements in comparison to healthy age-matched controls. Lung T1 and inter-quartile range (IQR) of T1 maps from 24 COPD subjects and 12 healthy age-matched non-smokers were retrospectively analyzed from an institutional review board approved study. The subjects underwent PFTs and two separate MR imaging sessions at 1.5 tesla to test T1 repeatability. CT scans were performed on the COPD subjects. T1 repeatability (intraclass correlation coefficient) was 0.72 for repeated scans acquired on two visits. The lung T1 was significantly shorter (p < 0.0001) and T1 IQR was significantly larger (p = 0.0002) for the COPD subjects compared to healthy controls. Lung T1 significantly (p = 0.001) correlated with lung density assessed with CT. Strong significant correlations (p < 0.0001) between lung T1 and all PFT measurements were observed. Cigarette exposure did not correlate with lung T1 in COPD subjects. In conclusion, lung MRI T1 mapping shows potential as a repeatable, radiation free, non-invasive imaging technique in the evaluation of COPD.


Assuntos
Pulmão/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Doença Pulmonar Obstrutiva Crônica/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Pulmão/fisiopatologia , Masculino , Pessoa de Meia-Idade , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Testes de Função Respiratória , Estudos Retrospectivos , Fumar/efeitos adversos , Tomografia Computadorizada por Raios X/métodos
14.
Magn Reson Med ; 73(1): 244-53, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24515975

RESUMO

PURPOSE: There is currently no adequate method of mapping physiologic and pathophysiologic tissue albumin concentrations in human subjects. The objective of this study was to devise and evaluate a biomarker of regional albumin concentration using gadofosveset-enhanced MRI. THEORY AND METHODS: A binding and relaxation model was devised and evaluated in vitro in solutions of albumin at 3.0 Tesla (T) and 4.7T. The method was evaluated in the heart in seven volunteers at 3.0T. RESULTS: MRI-derived estimates of albumin concentration were in good agreement with true values over the range 0.1-1.0 mM (Pearson correlation coefficients of 0.85 and 0.88 for 3.0T and 4.7T, respectively). The mean calculated albumin concentration in the myocardium for the volunteers was 0.02 mM (range, 0.01-0.03 mM). CONCLUSION: Accurate estimates of albumin concentration in vitro suggest this may be a viable noninvasive alternative to existing techniques. In the myocardium the MRI-derived estimates of albumin concentration indicate the practical feasibility of the technique but were below expected values. Gadofosveset-enhanced MR relaxometry has potential in providing biomarkers of regional albumin concentration; further evaluation is required before it can be used reliably in vivo.


Assuntos
Albuminas/metabolismo , Gadolínio/farmacocinética , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Imagem Molecular/métodos , Miocárdio/metabolismo , Compostos Organometálicos/farmacocinética , Adulto , Biomarcadores/metabolismo , Simulação por Computador , Meios de Contraste/farmacocinética , Estudos de Viabilidade , Feminino , Coração/anatomia & histologia , Humanos , Masculino , Modelos Biológicos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Distribuição Tecidual
15.
J Magn Reson Imaging ; 42(6): 1759-64, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26012876

RESUMO

PURPOSE: To evaluate between-site agreement of apparent diffusion coefficient (ADC) measurements in preclinical magnetic resonance imaging (MRI) systems. MATERIALS AND METHODS: A miniaturized thermally stable ice-water phantom was devised. ADC (mean and interquartile range) was measured over several days, on 4.7T, 7T, and 9.4T Bruker, Agilent, and Magnex small-animal MRI systems using a common protocol across seven sites. Day-to-day repeatability was expressed as percent variation of mean ADC between acquisitions. Cross-site reproducibility was expressed as 1.96 × standard deviation of percent deviation of ADC values. RESULTS: ADC measurements were equivalent across all seven sites with a cross-site ADC reproducibility of 6.3%. Mean day-to-day repeatability of ADC measurements was 2.3%, and no site was identified as presenting different measurements than others (analysis of variance [ANOVA] P = 0.02, post-hoc test n.s.). Between-slice ADC variability was negligible and similar between sites (P = 0.15). Mean within-region-of-interest ADC variability was 5.5%, with one site presenting a significantly greater variation than the others (P = 0.0013). CONCLUSION: Absolute ADC values in preclinical studies are comparable between sites and equipment, provided standardized protocols are employed.


Assuntos
Imagem de Difusão por Ressonância Magnética/instrumentação , Imagem de Difusão por Ressonância Magnética/veterinária , Aumento da Imagem/instrumentação , Interpretação de Imagem Assistida por Computador/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Europa (Continente) , Imagens de Fantasmas/veterinária , Imagens de Fantasmas/virologia , Estados Unidos
16.
Magn Reson Med ; 71(3): 1299-311, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23666778

RESUMO

PURPOSE: To develop significance testing methodology applicable to spatially heterogeneous parametric maps of biophysical and physiological measurements arising from imaging studies. THEORY: Heterogeneity can confound statistical analyses. Indexed distribution analysis (IDA) transforms a reference distribution, establishing correspondences across parameter maps to which significance tests are applied. METHODS: Well-controlled simulated and clinical K(trans) data from a dynamic contrast-enhanced magnetic resonance imaging study of bevacizumab were analyzed using conventional significance tests of parameter averages, histogram analysis, and IDA. Repeated pretreatment scans provided negative control; a post treatment scan provided positive control. RESULTS: Histogram analysis was insensitive to simulated and known effects. Simulation: conventional analysis identified treatment effect (P ≈ 5 × 10(-4)) and direction, but underestimated magnitude (relative error 67-81%); IDA identified treatment effect (P = 0.001), magnitude, direction, and spatial extent (100% accuracy). Bevacizumab: conventional analysis was sensitive to treatment effect (P = 0.01; 95% confidence interval on K(trans) decrease: 23-37%); IDA was sensitive to treatment effect (P < 0.05; K(trans) decrease approximately 25%), inferred its spatial extent to be 94-96%, and inferred that K(trans) decrease is independent of baseline value, an inference that conventional and histogram analyses cannot make. CONCLUSIONS: In the presence of heterogeneity, IDA can accurately infer the magnitude, direction, and spatial extent of between samples of parametric maps, which can be visualized spatially with respect to the original parameter maps.


Assuntos
Anticorpos Monoclonais Humanizados/uso terapêutico , Neoplasias Colorretais/tratamento farmacológico , Neoplasias Colorretais/patologia , Interpretação Estatística de Dados , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Bevacizumab , Biomarcadores , Meios de Contraste , Humanos , Aumento da Imagem/métodos , Prognóstico , Reprodutibilidade dos Testes , Tamanho da Amostra , Sensibilidade e Especificidade , Análise Espaço-Temporal , Resultado do Tratamento
17.
Magn Reson Med ; 71(5): 1854-62, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-23798369

RESUMO

PURPOSE: There is a clinical need for noninvasive, nonionizing imaging biomarkers of tumor hypoxia and oxygenation. We evaluated the relationship of T1 -weighted oxygen-enhanced magnetic resonance imaging (OE-MRI) measurements to histopathology measurements of tumor hypoxia in a murine glioma xenograft and demonstrated technique translation in human glioblastoma multiforme. METHODS: Preclinical evaluation was performed in a subcutaneous murine human glioma xenograft (U87MG). Animals underwent OE-MRI followed by dynamic contrast-enhanced MRI (DCE-MRI) and histological measurement including reduced pimonidazole adducts and CD31 staining. Area under the curve (AUC) was measured for the R1 curve for OE-MRI and the gadolinium concentration curve for DCE-MRI. Clinical evaluation in five patients used analogous imaging protocols and analyses. RESULTS: Changes in AUC of OE-MRI (AUCOE ) signal were regionally heterogeneous across all U87MG tumors. Tumor regions with negative AUCOE typically had low DCE-MRI perfusion, had positive correlation with hypoxic area (P = 0.029), and had negative correlation with vessel density (P = 0.004). DCE-MRI measurements did not relate to either hypoxia or vessel density in U87MG tumors. Clinical data confirmed comparable signal changes in patients with glioblastoma. CONCLUSION: These data support further investigation of T1 -weighted OE-MRI to identify regional tumor hypoxia. The quantification of AUCOE has translational potential as a clinical biomarker of hypoxia.


Assuntos
Neoplasias Encefálicas/metabolismo , Glioblastoma/metabolismo , Glioma/metabolismo , Imageamento por Ressonância Magnética/métodos , Oximetria/métodos , Oxigênio/metabolismo , Animais , Biomarcadores Tumorais/metabolismo , Neoplasias Encefálicas/patologia , Hipóxia Celular , Linhagem Celular Tumoral , Feminino , Glioblastoma/patologia , Glioma/patologia , Humanos , Camundongos , Camundongos Nus , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Distribuição Tecidual
18.
Front Med (Lausanne) ; 11: 1347267, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38818386

RESUMO

Immune-based treatment approaches are successfully used for the treatment of patients with cancer. While such therapies can be highly effective, many patients fail to benefit. To provide optimal therapy choices and to predict treatment responses, reliable biomarkers for the assessment of immune features in patients with cancer are of significant importance. Biomarkers (BM) that enable a comprehensive and repeatable assessment of the tumor microenvironment (TME), the lymphoid system, and the dynamics induced by drug treatment can fill this gap. Medical imaging, notably positron emission tomography (PET) and magnetic resonance imaging (MRI), providing whole-body imaging BMs, might deliver such BMs. However, those imaging BMs must be well characterized as being 'fit for purpose' for the intended use. This review provides an overview of the key steps involved in the development of 'fit-for-purpose' imaging BMs applicable in drug development, with a specific focus on pharmacodynamic biomarkers for assessing the TME and its modulation by immunotherapy. The importance of the qualification of imaging BMs according to their context of use (COU) as defined by the Food and Drug Administration (FDA) and National Institutes of Health Biomarkers, EndpointS, and other Tools (BEST) glossary is highlighted. We elaborate on how an imaging BM qualification for a specific COU can be achieved.

19.
NMR Biomed ; 26(10): 1258-70, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23564602

RESUMO

Drug-induced liver injury (DILI) is a clinically important adverse drug reaction, which prevents the development of many otherwise safe and effective new drugs. Currently, there is a lack of sensitive and specific biomarkers that can be used to predict, assess and manage this toxicity. The aim of this work was to evaluate gadoxetate-enhanced MRI as a potential novel biomarker of hepatobiliary transporter inhibition in the rat. Initially, the volume fraction of extracellular space in the liver was determined using gadopentetate to enable an estimation of the gadoxetate concentration in hepatocytes. Using this information, a compartmental model was developed to characterise the pharmacokinetics of hepatic uptake and biliary excretion of gadoxetate. Subsequently, we explored the impact of an investigational hepatobiliary transporter inhibitor on the parameters of the model in vivo in rats. The investigational hepatobiliary transporter inhibitor reduced both the rate of uptake of gadoxetate into the hepatocyte, k1 , and the Michaelis-Menten constant, Vmax , characterising its excretion into bile, whereas KM values for biliary efflux were increased. These effects were dose dependent and correlated with effects on plasma chemistry markers of liver dysfunction, in particular bilirubin and bile acids. These results indicate that gadoxetate-enhanced MRI provides a novel functional biomarker of inhibition of transporter-mediated hepatic uptake and clearance in the rat. Since gadoxetate is used clinically, the technology has the potential to provide a translatable biomarker of drug-induced perturbation of hepatic transporters that may also be useful in humans to explore deleterious functional alterations caused by transporter inhibition.


Assuntos
Sistema Biliar/metabolismo , Biomarcadores/metabolismo , Meios de Contraste , Gadolínio DTPA , Fígado/metabolismo , Imageamento por Ressonância Magnética , Proteínas de Membrana Transportadoras/metabolismo , Membro 11 da Subfamília B de Transportadores de Cassetes de Ligação de ATP , Transportadores de Cassetes de Ligação de ATP/antagonistas & inibidores , Transportadores de Cassetes de Ligação de ATP/metabolismo , Animais , Transporte Biológico , Espaço Extracelular/metabolismo , Gadolínio DTPA/farmacocinética , Células HEK293 , Hepatócitos/metabolismo , Humanos , Transportador 1 de Ânion Orgânico Específico do Fígado , Masculino , Proteína 2 Associada à Farmacorresistência Múltipla , Proteínas Associadas à Resistência a Múltiplos Medicamentos/antagonistas & inibidores , Proteínas Associadas à Resistência a Múltiplos Medicamentos/metabolismo , Transportadores de Ânions Orgânicos/antagonistas & inibidores , Transportadores de Ânions Orgânicos/metabolismo , Ratos , Ratos Wistar
20.
J Magn Reson Imaging ; 38(2): 429-34, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23293077

RESUMO

PURPOSE: To investigate the combined use of hyperoxia-inducedΔR(2) * and ΔR(1) as a noninvasive imaging biomarker of tumor hypoxia. MATERIALS AND METHODS: MRI was performed on rat GH3 prolactinomas (n = 6) and human PC3 prostate xenografts (n = 6) propagated in nude mice. multiple gradient echo and inversion recovery truefisp images were acquired from identical transverse slices to quantify tumor R(2) * and R(1)before and during carbogen (95% O2 /5% CO2 ) challenge, and correlates of ΔR(2) * and ΔR(1) assessed. RESULTS: Mean baseline R(2) * and R(1) were 119 ± 7 s(-1) and 0.6 ± 0.03 s(-1) for GH3 prolactinomas and 77 ± 12 s(-1) and 0.7 ± 0.02 s(-1) for PC3 xenografts, respectively. During carbogen breathing, mean ΔR(2) * and ΔR(1) were -20 ± 8 s(-1) and 0.08 ± 0.03 s(-1) for GH3 and -0.5 ± 1 s(-1) and 0.2 ± 0.08 s(-1) for the PC3 tumors, respectively. A pronounced relationship betweenΔR(2) * and ΔR(1) was revealed. CONCLUSION: Considering the blood oxygen-hemoglobin dissociation curve, fast R2 * suggested that GH3 prolactinomas were more hypoxic at baseline, and their carbogen response dominated by increased hemoglobin oxygenation, evidenced by highly negative ΔR(2) *. PC3 tumors were less hypoxic at baseline, and their response to carbogen dominated by increased dissolved oxygen, evidenced by highly positive ΔR(1) . Because the two biomarkers are sensitive to different oxygenation ranges, the combination of ΔR(2) * and ΔR(1) may better characterize tumor hypoxia than each alone.


Assuntos
Algoritmos , Interpretação de Imagem Assistida por Computador/métodos , Neoplasias Experimentais/diagnóstico , Neoplasias Experimentais/metabolismo , Oximetria/métodos , Oxigênio/metabolismo , Animais , Biomarcadores/metabolismo , Biomarcadores Tumorais/metabolismo , Linhagem Celular Tumoral , Humanos , Aumento da Imagem/métodos , Camundongos , Camundongos Nus , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa