Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Eur Radiol ; 26(9): 3223-33, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26679184

RESUMO

OBJECTIVES: To evaluate the potential of grating-based phase-contrast computed-tomography (gb-PCCT) to classify human carotid and coronary atherosclerotic plaques according to modified American Heart Association (AHA) criteria. METHODS: Experiments were carried out at a laboratory-based set-up consisting of X-ray tube (40 kVp), grating-interferometer and detector. Eighteen human carotid and coronary artery specimens were examined. Histopathology served as the standard of reference. Vessel cross-sections were classified as AHA lesion type I/II, III, IV/V, VI, VII or VIII plaques by two independent reviewers blinded to histopathology. Conservative measurements of diagnostic accuracies for the detection and differentiation of plaque types were evaluated. RESULTS: A total of 127 corresponding gb-PCCT/histopathology sections were analyzed. Based on histopathology, lesion type I/II was present in 12 (9.5 %), III in 18 (14.2 %), IV/V in 38 (29.9 %), VI in 16 (12.6 %), VII in 34 (26.8 %) and VIII in 9 (7.0 %) cross-sections. Sensitivity, specificity and positive and negative predictive value were ≥0.88 for most analyzed plaque types with a good level of agreement (Cohen's kappa = 0.90). Overall, results were better in carotid (kappa = 0.97) than in coronary arteries (kappa = 0.85). Inter-observer agreement was high with kappa = 0.85, p < 0.0001. CONCLUSIONS: These results indicate that gb-PCCT can reliably classify atherosclerotic plaques according to modified AHA criteria with excellent agreement to histopathology. KEY POINTS: • Different atherosclerotic plaque types display distinct morphological features in phase-contrast CT. • Phase-contrast CT can detect and differentiate AHA plaque types. • Calcifications caused streak artefacts and reduced sensitivity in type VI lesions. • Overall agreement was higher in carotid than in coronary arteries.


Assuntos
Artérias Carótidas/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Placa Aterosclerótica/classificação , Placa Aterosclerótica/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , American Heart Association , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Placa Aterosclerótica/patologia , Estudos Prospectivos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Estados Unidos
2.
Invest Radiol ; 53(1): 26-34, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-28846552

RESUMO

OBJECTIVES: Grating-based phase-contrast computed tomography (gb-PCCT) relies on x-ray refraction instead of absorption to generate high-contrast images in biological soft tissue. The aim of this study was to evaluate the potential of gb-PCCT for the depiction of structural changes in heart disease. MATERIALS AND METHODS: Four human heart specimens from patients with hypertensive disease, ischemic disease, dilated heart disease, and cardiac lipomatosis were examined. The gb-PCCT setup consisted of an x-ray tube (40 kV, 70 mA), grating-interferometer, and detector, and allowed simultaneous acquisition of phase- and absorption-contrast data. With histopathology as the standard of reference, myocardium (MC), fibrotic scar (FS), interstitial fibrosis (IF), and fatty tissue (FT) were visually and quantitatively evaluated. Systematic differences in absorption- and phase-contrast Hounsfield units (HUabs and HUp) were assessed. RESULTS: Thirteen corresponding cross-sections were included, and MC, FS, IF, and FT were found in 13 (100%), 4 (30.8%), 7 (53.8%), and 13 (100%) cross-sections, respectively. Mean HUp/HUabs were 52.5/54.1, 86.6/69.7, 62.4/62.3, and -38.6/-258.9 for MC, FS, IF, and FT, respectively. An overlap in HUabs was observed for MC and IF (P = 0.84) but not for HUp (P < 0.01). Contrast-to-noise ratios were significantly higher in phase- than in absorption-contrast for MC/FT (35.4 vs 7.8; P < 0.01) and for MC/FS (12.3 vs 0.2; P < 0.01). CONCLUSIONS: Given its superior soft tissue contrast, gb-PCCT is able to depict structural changes in different cardiomyopathies, which can currently not be obtained by x-ray absorption-based imaging methods. If current technical limitations can be overcome, gb-PCCT may evolve as a powerful tool for the anatomical assessment of cardiomyopathy.


Assuntos
Meios de Contraste , Cardiopatias/diagnóstico por imagem , Coração/diagnóstico por imagem , Intensificação de Imagem Radiográfica/métodos , Tomografia Computadorizada por Raios X/métodos , Estudos de Avaliação como Assunto , Humanos , Reprodutibilidade dos Testes
3.
Eur J Radiol ; 94: 38-45, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28941758

RESUMO

OBJECTIVES: Dark-field imaging based on small angle X-ray scattering has been shown to be highly sensitive for microcalcifications, e.g. in breast tissue. We hypothesized (i) that high signal areas in dark-field imaging of atherosclerotic plaque are associated with microcalcifications and (ii) that dark-field imaging is more sensitive for microcalcifications than attenuation-based imaging. METHODS: Fifteen coronary artery specimens were examined at an experimental set-up consisting of X-ray tube (40kV), grating-interferometer and detector. Tomographic dark-field-, attenuation-, and phase-contrast data were simultaneously acquired. Histopathology served as standard of reference. To explore the potential of dark field imaging in a full-body CT system, simulations were carried out with spherical calcifications of different sizes to simulate small and intermediate microcalcifications. RESULTS: Microcalcifications were present in 10/10 (100%) cross-sections with high dark-field signal and without evidence of calcifications in attenuation- or phase contrast. In positive controls with high signal areas in all three modalities, 10/10 (100%) cross-sections showed macrocalcifications. In negative controls without high signal areas, no calcifications were detected. Simulations showed that the microcalcifications generate substantially higher dark-field than attenuation signal. CONCLUSIONS: Dark-field imaging is highly sensitive for microcalcifications in coronary atherosclerotic plaque and might provide complementary information in the assessment of plaque instability.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Autopsia , Calcinose/diagnóstico por imagem , Calcinose/patologia , Doença da Artéria Coronariana/patologia , Humanos , Estudos Prospectivos , Reprodutibilidade dos Testes
4.
Int J Sports Phys Ther ; 11(2): 164-74, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27104050

RESUMO

BACKGROUND: Chronic ankle instability (CAI) is a condition that often develops after repeated ankle sprains, increasing the suceptability of the ankle to move into excessive inversion when walking on unstable surfaces. Treatment for CAI costs approximately three billion health care dollars annually. Currently, common diagnostic tools used to identify ankle instability are arthroscopy, imaging, manual laxity testing, and self-reported questionnaires. PURPOSE: The purpose of this systematic review was to investigate the effectiveness of ultrasonography in diagnosing CAI, in comparison with other diagnostic tools. METHODS: Search limits: articles published between the years 2000-2015, and articles that were peer reviewed and published in the English language. Databases searched: CINAHL, PubMed, Medline, Medline Plus, Science Direct, OVID, Cochrane, and EBSCO. Titles and abstracts of the 1,420 articles were screened for the inclusion criteria by two independent raters, with discrepancies solved by a third rater. The modified 14-point Quality Assessment of Diagnostic Accuracy Studies (QUADAS) scale was used to assess methodological quality of included articles. RESULTS: Six high quality articles were included in this systematic review, as indicated by high scores on the QUADAS scale, ranging from 10 to 13. Sensitivity of US ranged from: 84.6 % -100%, specificity of US ranged from: 90.9% - 100% and accuracy ranged from: 87% - 90.9%. DISCUSSION: The results of the included studies suggest that US is able to accurately differentiate between the grades of ankle sprains and between a lax ligament, torn ligament, thick ligament, absorbed ligament and a non-union avulsion fracture. These findings indicate that US is a reliable method for diagnosing CAI, and that US is able to classify the degree of instability. CONCLUSION: Researchers found that US is effective, reliable, and accurate in the diagnosis of CAI. CLINICAL IMPLICATIONS: US would allow for earlier diagnosis, which could increase the quality of care as well as decrease the number of outpatient visits. This could lead to improvement in treatment plans, goals and rehabilitation outcomes. LEVEL OF EVIDENCE: 1a.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa