Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
1.
Anal Chem ; 2024 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-38317503

RESUMO

Lateral flow immunoassay (LFIA) has played a vital role in point-of-care (POC) testing on account of its simplicity, rapidity, and low cost. However, the low sensitivity and difficulty of quantitation limit its further development. Sensitive markers with new detection modes are being developed to dramatically improve LFIA's performance. Herein, a ligand-complex approach was proposed to uniformly coat a thin layer of Au onto Ag triangular nanoplates (Ag TNPs) without etching the Ag cores, which not only retain the unique optical properties from Ag TNPs but also acquire the surface stability and biocompatibility of gold. The localized surface plasmon resonance absorption of these Ag@Au TNPs could be finely adjusted from visible (550 nm) to the second near-infrared region (NIR-II) (1100 nm), and even longer, by simply adjusting the ratio between edge length and thickness. Utilizing the Ag@Au TNPs as new markers for LFIA, a highly sensitive colorimetric and photothermal dual-mode detection of the SARS-CoV-2 nucleocapsid protein was achieved with a very low background. The Ag@Au TNPs showed an exceedingly high photothermal conversion efficiency of 61.4% (ca. 2 times higher than that of Au nanorods), endowing the LFIA method with a low photothermal detection limit (40 pg/mL), which was 25-fold lower than that of the colorimetric results. The generality of the method was further verified by the sensitive and accurate analysis of cardiac troponin I (cTnI). This method is robust, reproducible, and highly specific and has been successfully applied to SARS-COV-2 detection in 35 clinical samples with satisfactory results, demonstrating its potential for POC applications.

2.
Anal Chem ; 96(15): 6065-6071, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38569047

RESUMO

The conventional lateral flow immunoassay (LFIA) method using colloidal gold nanoparticles (Au NPs) as labeling agents faces two inherent limitations, including restricted sensitivity and poor quantitative capability, which impede early viral infection detection. Herein, we designed and synthesized CsPbBr3 perovskite quantum dot-based composite nanoparticles, CsPbBr3@SiO2@Fe3O4 (CSF), which integrated fluorescence detection and magnetic enrichment properties into LFIA technology and achieved rapid, sensitive, and convenient quantitative detection of the SARS-CoV-2 virus N protein. In this study, CsPbBr3 served as a high-quantum-yield fluorescent signaling probe, while SiO2 significantly enhanced the stability and biomodifiability of CsPbBr3. Importantly, the SiO2 shell shows relatively low absorption or scattering toward fluorescence, maintaining a quantum yield of up to 74.4% in CsPbBr3@SiO2. Assembly of Fe3O4 nanoparticles mediated by PEI further enhanced the method's sensitivity and reduced matrix interference through magnetic enrichment. Consequently, the method achieved a fluorescent detection range of 1 × 102 to 5 × 106 pg·mL-1 after magnetic enrichment, with a limit of detection (LOD) of 58.8 pg·mL-1, representing a 13.3-fold improvement compared to nonenriched samples (7.58 × 102 pg·mL-1) and a 2-orders-of-magnitude improvement over commercial colloidal gold kits. Furthermore, the method exhibited 80% positive and 100% negative detection rates in clinical samples. This approach holds promise for on-site diagnosis, home-based quantitative tests, and disease procession evaluation.


Assuntos
Nanopartículas Metálicas , Dióxido de Silício , Ouro , Corantes Fluorescentes , Imunoensaio/métodos , Coloide de Ouro
3.
Anal Bioanal Chem ; 415(4): 545-554, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36414739

RESUMO

Serological antibody tests are useful complements of nuclei acid detection for SARS-CoV-2 diagnosis, which can significantly improve diagnostic accuracy. However, antibody detection in serum or plasma remains challenging to do with high sensitivity. In this study, Ag nanoparticles with ultra-thin Au shells embedded with 4-mercaptobenzoic acid (MBA) (AgMBA@Au) were manufactured and then assembled onto Fe3O4 surface by electrostatic interaction to construct the Fe3O4-AgMBA@Au nanoparticles (NPs) with magnetic-Raman-colorimetric properties. Based on the composite nanoparticles, a colorimetric and Raman dual-mode lateral flow immunoassay (LFIA) for ultrasensitive identification of SARS-CoV-2 nucleocapsid (N) protein antibody was constructed. The magnetic nanoparticles (Fe3O4 NPs) were acted as the core and coated a layer of AgMBA@Au particles on the surface by electrostatic interaction to prepare Fe3O4-AgMBA@Au NPs, which can amplify the SERS signal due to multiple AgMBA@Au particles concentrated on a single magnetic nanoparticle. Moreover, the Fe3O4-AgMBA@Au NPs facilitated pre-purifying sample using magnetic separation, and complex matrix interference would be greatly decreased in the detection. The Fe3O4-AgMBA@Au NPs modified with N protein recognized and bound with N protein antibodies, which were trapped on the T-line, forming color band for observing detection. Under optimal conditions, the N protein antibodies could be qualitatively detected in colorimetric mode with the visual limit of 10-8 mg/mL and quantitatively detected by SERS signals between 10-6 and 10-10 mg /mL with 0.08 pg/mL detection limit. The coefficients variations (CV) of intra-assay was 8.0%, whereas of inter-assay was 11.7%, confirming of good reproducibility. Finally, this approach was able to discriminate between positive, negative, and weakly positive samples when detecting 107 clinical serum samples. The process enables highly sensitive quantitative assays that are valuable for evaluating disease processes and guiding treatment. Colorimetric and Raman dual-mode LFIA detection of SARS-CoV-2 N protein antibody based on Fe3O4-AgMBA@Au nanoparticles.


Assuntos
Anticorpos Antivirais , COVID-19 , Proteínas do Nucleocapsídeo de Coronavírus , Ouro , Nanopartículas Metálicas , SARS-CoV-2 , Prata , Humanos , Colorimetria , COVID-19/diagnóstico , Teste para COVID-19 , Imunoensaio , Reprodutibilidade dos Testes , SARS-CoV-2/imunologia , Análise Espectral Raman , Proteínas do Nucleocapsídeo de Coronavírus/imunologia , Anticorpos Antivirais/análise
4.
Mikrochim Acta ; 190(2): 57, 2023 01 18.
Artigo em Inglês | MEDLINE | ID: mdl-36652031

RESUMO

Au-Fe3O4 multifunctional nanoparticles (NPs) were synthesized and integrated with lateral flow immunoassay (LFIA) for dual-mode detection of Salmonella typhimurium. The Au-Fe3O4 NPs not only combined excellent local surface plasmon resonance characteristics and superparamagnetic properties, but also exhibited good photothermal effect. In the detection, antibody-conjugated Au-Fe3O4 NPs first captured S. typhimurium from complex matrix, which was then loaded on the LFIA strip and trapped by the T-line. By observing the color bands with the naked eyes, qualitative detection was performed free of instrument. By measuring the photothermal signal, quantification was achieved with a portable infrared thermal camera. The introduction of magnetic separation achieved the enrichment and purification of target bacteria, thus enhancing the detection sensitivity and reducing interference. This dual-mode LFIA achieved a visual detection limit of 5 × 105 CFU/mL and a photothermal detection limit of 5 × 104 CFU/mL. Compared with traditional Au-based LFIA, this dual-mode LFIA increased the detection sensitivity by 2 orders of magnitude and could be directly applied to unprocessed milk sample. Besides, this dual-mode LFIA showed good reproducibility and specificity. The intra-assay and inter-assay variation coefficients were 3.0% and 7.9%, and with this dual-mode LFIA, other bacteria hardly produced distinguishable signals. Thus, the Au-Fe3O4 NPs-based LFIA has potential to increase the efficiency of pandemic prevention and control. Au-Fe3O4 nanoparticle proved to be a promising alternative reporter for LFIA, achieving multifunctions: target purification, target enrichment, visual qualitation, and instrumental quantification, which improved the limitations of traditional LFIA.


Assuntos
Nanopartículas Metálicas , Nanopartículas Multifuncionais , Salmonella typhimurium , Colorimetria , Reprodutibilidade dos Testes , Imunoensaio
5.
Anal Chem ; 94(23): 8466-8473, 2022 06 14.
Artigo em Inglês | MEDLINE | ID: mdl-35657150

RESUMO

Immunoglobulin detection is essential for diagnosing progression of SARS-CoV-2 infection, for which SARS-CoV-2 IgG is one of the most important indexes. In this paper, Ag nanoparticles with ultrathin Au shells (∼2 nm) embedded with 4-mercaptobenzoic acid (MBA) (AgMBA@Au) were manufactured via a ligand-assisted epitaxial growth method and integrated into lateral flow immunoassay (LFIA) for colorimetric and SERS dual-mode detection of SARS-CoV-2 IgG. AgMBA@Au possessed not only the surface chemistry advantages of Au but also the superior optical characteristics of Ag. Moreover, the nanogap between the Ag core and the Au shell also greatly enhanced the Raman signal. After being modified with anti-human antibodies, AgMBA@Au recognized and combined with SARS-CoV-2 IgG, which was captured by the SARS-CoV-2 spike protein on the T line. Qualitative analysis was achieved by visually observing the color of the T line, and quantitative analysis was conducted by measuring the SERS signal with a sensitivity four orders of magnitude higher (detection limit: 0.22 pg/mL). The intra-assay and inter-assay variation coefficients were 7.7 and 10.3%, respectively, and other proteins at concentrations of 10 to 20 times higher than those of SARS-CoV-2 IgG could hardly produce distinguishable signals, confirming good reproducibility and specificity. Finally, this method was used to detect 107 clinical serum samples. The results agreed well with those obtained from enzyme-linked immunosorbent assay kits and were significantly better than those of the colloidal gold test strips. Therefore, this dual-mode LFIA has great potential in clinical practical applications and can be used to screen and trace the early immune response of SARS-CoV-2.


Assuntos
COVID-19 , Nanopartículas Metálicas , Anticorpos Antivirais , COVID-19/diagnóstico , Colorimetria , Humanos , Imunoensaio/métodos , Imunoglobulina G , Reprodutibilidade dos Testes , SARS-CoV-2 , Prata , Análise Espectral Raman/métodos , Glicoproteína da Espícula de Coronavírus
6.
Small ; 17(51): e2104596, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34741431

RESUMO

Magnetic relaxation switching (MRS) sensors have shown great potential in food safety monitoring due to their high signal-to-noise ratio and simplicity, but they often suffer from insufficient sensitivity and stability due to the lack of excellent magnetic nanoprobes. Herein, dumbbell-like Au-Fe3 O4 nanoparticles are designed as magnetic nanoprobes for developing an aflatoxin B1-MRS immunosensor. The Fe3 O4 portion in the Au-Fe3 O4 nanoparticles functions as the magnetic probe to provide transverse relaxation signals, while the Au segments serve as a bridge to grow Ag shell and assemble the Au-Fe3 O4 nanoparticles, thus modulating transverse relaxation time of surrounding water molecular. The formation of Ag@Au-Fe3 O4 is triggered by hydrogen peroxide. After degraded by horseradish peroxidase, hydrogen peroxide reduces Ag+ to Ag nanoparticles which assemble dispersed Au-Fe3 O4 to aggregated Ag@Au-Fe3 O4 , thus dramatically improving the sensitivity of traditional MRS sensor. Combined with competitive immunoreaction, this Ag@Au-Fe3 O4 -MRS immunosensor can detect aflatoxin B1 with a high sensitivity (3.81 pg mL-1 ), which improved about 21 folds and 9 folds than those of enzyme-linked immunosorbent assay and high-performance liquid chromatography (HPLC), respectively. The good consistency with HPLC in real samples detection indicates the good accuracy of this immunosensor. This Ag@Au-Fe3 O4 -MRS immunosensor offers an attractive tool for detection of harmful substances.


Assuntos
Técnicas Biossensoriais , Nanopartículas Metálicas , Aflatoxina B1/análise , Ouro , Peróxido de Hidrogênio , Imunoensaio , Fenômenos Magnéticos , Prata
7.
Anal Chem ; 92(14): 9989-9996, 2020 07 21.
Artigo em Inglês | MEDLINE | ID: mdl-32551556

RESUMO

In situ monitoring of products generated by important heterogeneous catalytic reactions is of great significance for chemical industry, particularly when the products or intermediates are not sufficiently stable or occur at trace-level concentrations. It is therefore highly desirable to develop an integrated in situ catalysis and extraction method, which can simultaneously catalyze the reaction and enrich products while maintaining compatibility with analytical instrumentation. Herein, we propose an approach by depositing different types of metal nanocrystals, including gold, platinum, and palladium nanoparticles, onto fibrous silica microspheres coated fibers for integrated in situ catalysis and extraction. As a proof-of-concept, several typical chemical reactions, including the reduction of p-nitrophenol, epoxidation of styrene, oxidation of benzyl alcohol, and dechlorination of p-chlorophenol, were investigated to validate the feasibility of this method. Our results show that these coatings not only function as catalysts to accelerate the selected reactions but also serve as adsorbents to extract the reactants, intermediates, and products for direct gas chromatographic analysis, suggesting the viability of this approach for the in situ evaluation of catalytic processes. By this approach, the yield, selectivity, and kinetics of a reaction can be readily assessed. This approach can also be extended to investigate the catalytic performance of the same metal nanocrystals with different morphology, surface facet, structure, or surface functionalization. This approach will find broad generality for assessing the catalytic efficiency and selectivity of new catalysts or new chemical reactions and dynamic processes in these reactions.

8.
Analyst ; 144(15): 4582-4588, 2019 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-31236555

RESUMO

Plasmonic nanostructures have been broadly used for chemical detections, but their applications are limited by slow detection rates, insufficient visual resolution and sensitivity due to the chemical and structural stability of conventional plasmonic nanomaterials. It is thus essential to develop strategies to enhance the detection kinetics while promoting their excellent plasmonic properties. In this work, a colorimetric assay for HCHO measurement is developed based on the fact that HCHO can react with Tollens' reagent to anisotropically deposit a layer of silver shells onto the bone-shaped gold nanorod (Au NR) cores. Compared to the routine rod-shaped Au NRs, the bone-shaped Au NRs facilitate the deposition of Ag onto the sunken section due to their unique concave structures, giving rise to fast reaction kinetics and detection rate. It is also important to point out that the surface ligand exchange from CTAB to CTAC is helpful to accelerate the deposition of silver onto Au NRs, which significantly shortens the reaction time. The preferential deposition of Ag on the concave Au NRs induces more dramatic morphology changes and therefore promotes the plasmonic shift of the bone-shaped Au NRs and improves the sensing efficiency. Correspondingly, the apparent color of the solution changes from light gray to dark blue, purple, red, orange and finally to yellow as the longitudinal localized surface plasmon resonance (LSPR) band shifts from 710 to 500 nm along with the emergence of a new LSPR band at 400 nm almost covering the full visible region. The colorimetric method developed enables sensitive detection of HCHO with a low detection limit (1 nM), wide linear range (0.1-50 µM), high visual resolution and good specificity against other common indoor gases. It was successfully applied to the detection of gaseous HCHO present in the air collected from a furniture plaza, showing its potential practicality for on-site HCHO analysis.


Assuntos
Poluentes Atmosféricos/análise , Cetrimônio/química , Formaldeído/análise , Ouro/química , Nanotubos/química , Hidróxido de Amônia/química , Anisotropia , Colorimetria/métodos , Limite de Detecção , Nitrato de Prata/química , Ressonância de Plasmônio de Superfície/métodos
9.
Phys Chem Chem Phys ; 20(9): 6330-6336, 2018 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-29435544

RESUMO

A covalently linked tetracene trimer with a "face-to-face" stacked structure was prepared and its molecular structure is characterized by 1H NMR, MALDI-TOF mass spectroscopy, and elemental analysis. The minimized molecular structure reveals that three tetracene subunits within this trimer adopt a partially "face-to-face" stacked configuration. Its absorption spectrum differs significantly from that of the monomeric and dimeric counterparts in solution due to the strong ground state interactions between the neighboring tetracene subunits. Its fluorescence is almost quenched completely. An ultrafast fluorescence decay component is observed in its fluorescence dynamics, indicating the presence of an ultrafast nonradiative decay channel in the trimer. The nonradiative channel is proved to be intramolecular singlet fission (iSF) by femto-second transient absorption studies. Different from the strongly coupled triplet state observed in the corresponding dimer, weakly coupled triplet states can be formed in this trimer. The triplet quantum yield of trimer 4 can reach up to 126% in solution.

10.
Mikrochim Acta ; 185(1): 77, 2017 12 22.
Artigo em Inglês | MEDLINE | ID: mdl-29594414

RESUMO

A one-step sandwich method is described for detecting proteins with magnetic nanospheres (MNs) and fluorescent nanospheres (FNs). Thrombin is selected as a model analyte to validate the method. Two DNA aptamers (Apt 29 and Apt 15 targeting two different exosites of thrombin) are chosen as recognition elements to modify MNs and FNs. The superparamagnetic MN-Apt 29 conjugate is used to separate and concentrate thrombin. The FN-Apt 15 conjugate encapsulates hundreds of fluorescent quantum dots and is used as reporter to provide a stable signal. Magnetic capture and fluorescence identification are performed simultaneously to form a sandwich complex (MN-Apt 29-thrombin-FN-Apt 15) for fluorescence determination (at excitation/emission wavelengths of 380/622 nm). The method is convenient, time saving, and gives a strong signal (compared to the two-step method where capture and identification are performed in two steps). The one-step method presented here is completed within 30 min and has a 3.5 ng·mL-1 (97 pM) detection limit. The method is reproducible, has an intra-assay variability of 1.5%, and an inter-assay variability of 4.9%. Other serum proteins (HSA, CEA, PSA, and AFP) do not interfere. The method was also applied to analyze serum samples. Almost the same fluorescence intensity was measured when analyzing 1% serum samples (compared to buffer samples). Graphical abstract Magnetic nanospheres with excellent superparamagnetic property and fluorescent QD-based nanospheres were prepared and used in a one-step sensitive method for detecting thrombin. The method exhibits good reproducibility, high specificity, and good selectivity.


Assuntos
Aptâmeros de Nucleotídeos/química , Nanosferas/química , Trombina/análise , Fluorescência , Limite de Detecção , Magnetismo , Pontos Quânticos , Reprodutibilidade dos Testes
11.
Anal Chem ; 88(20): 10134-10142, 2016 10 18.
Artigo em Inglês | MEDLINE | ID: mdl-27633565

RESUMO

Number concentration of nanoparticles is a critical and challenging parameter to be identified. Recently, gravimetric strategy is a fundamental method for absolute quantification, which is widely accepted and used by researchers, yet limited by the inaccuracy in measuring related parameters (e.g, density). Hence, we introduced isopycnic gradient centrifugation to determine the nanopartices' density and improved the current gravimetric method for more accuracy. In this work, polymer nanospheres were used as a model to validate this method. Through isopycnic gradient centrifugation, nanospheres finally reached the zone of equal density as them. By measuring the density of the medium solution in this zone, the nanospheres' density was identified. Then, the density was multiplied by the volume of a single nanosphere characterized by transmission electron microscopy (TEM), and the average weight of a single nanosphere was obtained. Using total weight of the nanospheres divided by the unit weight, their number concentration was quantified. Directly using the real density of the nanoparticles achieved more accurate quantification than the current gravimetric method which used the density of the bulk material counterparts for calculation. Besides, compared with the viscosity/light scattering method and the high-sensitivity flow cytometry (HSFCM) method (another two kinds of typical methods respectively based on light measurements and single particle counting), the improved gravimetric method showed better reproducibility and more convenience. Further, we modified the nanospheres with streptavidin (SA) and antibody, and through biorecognition interaction, we determined the amount of the active affinity sites on each biofunctional nanosphere. Moreover, their bioactivity in different storage conditions was monitored, which showed good stability even in PBS at 4 °C over one year. Our work provided a promising method for more accurately determining the absolute number concentration of nanoparticles and the active affinity sites on their surfaces, which would greatly facilitate their downstream applications.

12.
Anal Chem ; 88(12): 6577-84, 2016 06 21.
Artigo em Inglês | MEDLINE | ID: mdl-27253137

RESUMO

Sensitive and quantitative detection of protein biomarkers with a point-of-care (POC) assay is significant for early diagnosis, treatment, and prognosis of diseases. In this paper, a quantitative lateral flow assay with high sensitivity for protein biomarkers was established by utilizing fluorescent nanospheres (FNs) as reporters. Each fluorescent nanosphere (FN) contains 332 ± 8 CdSe/ZnS quantum dots (QDs), leading to its superstrong luminescence, 380-fold higher than that of one QD. Then a detection limit of 27.8 pM C-reaction protein (CRP) could be achieved with an immunofluorescent nanosphere (IFN)-based lateral flow test strip. The assay was 257-fold more sensitive than that with a conventional Au-based lateral flow test strip for CRP detection. Besides, the fluorescence intensity of FNs and bioactivity of IFNs were stable during 6 months of storage. Hence, the assay owns good reproducibility (intra-assay variability of 5.3% and interassay variability of 6.6%). Furthermore, other cancer biomarkers (PSA, CEA, AFP) showed negative results by this method, validating the excellent specificity of the method. Then the assay was successfully applied to quantitatively detect CRP in peripheral blood plasma samples from lung cancer and breast cancer patients, and healthy people, facilitating the diagnosis of lung cancer. It holds a good prospect of POC protein biomarker detection.


Assuntos
Proteína C-Reativa/análise , Imunofluorescência/métodos , Corantes Fluorescentes/química , Imunoconjugados/química , Nanosferas/química , Fitas Reagentes/análise , Animais , Técnicas Biossensoriais/métodos , Compostos de Cádmio/química , Fluorimunoensaio/métodos , Cabras , Humanos , Limite de Detecção , Camundongos , Neoplasias/sangue , Sistemas Automatizados de Assistência Junto ao Leito , Pontos Quânticos/química , Reprodutibilidade dos Testes , Compostos de Selênio/química , Sulfetos/química , Compostos de Zinco/química
13.
Small ; 11(39): 5280-8, 2015 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-26280101

RESUMO

Avian influenza A(H7N9) virus, which emerged in China in the spring of 2013, has infected hundreds of people and resulted in many deaths. Herein, a rapid and quantitative assay is proposed for the one-step detection of H7N9 virions. Immunomagnetic nanospheres (IMNs) and antibody-conjugated quantum dots (Ab-QDs) are simultaneously employed to capture and identify the target virus, leading to a high efficiency, good specificity, and strong anti-interference ability. Moreover, this reliable detection assay, which combines the efficient magnetic enrichment and the unique photophysical properties of QDs, can achieve a high sensitivity for a low detection limit. At the same time, this detection strategy shows great flexibility for employment in a variety of fluorescence detectors, including fluorescence spectrometry, microscope assays, and handheld UV lamp tests. Furthermore, our one-step detection strategy induces very little change in the integrity of the vulnerable virions, which enables additional genotyping testing following the fluorescence detection. The present study, thus, reports a rapid and quantitative approach for the detection of H7N9 virions based on simultaneous magnetic capture and QD labeling, thereby providing a higher probability for detection and therefore faster diagnosis of H7N9-infected patients.


Assuntos
Separação Imunomagnética/métodos , Subtipo H7N9 do Vírus da Influenza A/ultraestrutura , Microscopia de Fluorescência/métodos , Pontos Quânticos , Carga Viral/métodos , Vírion/ultraestrutura , Subtipo H7N9 do Vírus da Influenza A/isolamento & purificação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Coloração e Rotulagem/métodos , Vírion/isolamento & purificação
14.
Biophys J ; 107(1): 165-73, 2014 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-24988351

RESUMO

Bead-based assay is widely used in many bioanalytical applications involving the attachment of proteins and other biomolecules to the surface. For further understanding of the formation of a sphere-biomolecule complex and easily optimizing the use of spheres in targeted biological applications, it is necessary to know the kinetics of the binding reaction at sphere/solution interface. In our presented work, a simple fluorescence analysis method was employed to measure the kinetics for the binding of biotin to sphere surface-bound FITC-SA, based on the fact that the fluorescence intensity of FITC was proportionally enhanced by increasing the binding amount of biotin. By monitoring the time-dependent changes of FITC fluorescence, it was found that the binding rate constant of biotin to sphere surface-immobilized FITC-SA was much smaller than that of biotin to freely diffusing FITC-SA. This can be attributed to the decreased encounter frequency of the reaction pair, restricted motion of the attached biomolecule, and the weakened steric accessibility of the binding site. These factors would become more obvious when increasing the size of the sphere upon which the FITC-SA was immobilized. Additionally, the effect of nanoparticles on the diffusion-controlled bimolecular binding reaction was more evident than that on the chemical recognition-controlled binding reaction.


Assuntos
Biotina/química , Fluoresceína-5-Isotiocianato/química , Microesferas , Estreptavidina/química
15.
Anal Chem ; 86(9): 4618-26, 2014 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-24716801

RESUMO

Early detection and isolation of circulating tumor cells (CTCs) can provide helpful information for diagnosis, and functional readouts of CTCs can give deep insight into tumor biology. In this work, we presented a new strategy for simple isolation and release of CTCs using engineered nanobioprobes. The nanobioprobes were constructed by Ca(2+)-assisted layer-by-layer assembly of alginate onto the surface of fluorescent-magnetic nanospheres, followed by immobilization of biotin-labeled anti-EpCAM. As-prepared anti-EpCAM-functionalized nanobioprobes were characterized with integrated features of anti-EpCAM-directed specific recognition, fluorescent magnetic-driven cell capture, and EDTA-assisted cell release, which can specifically recognize 10(2) SK-BR-3 cells spiked in 1 mL of lysed blood or human whole blood samples with 89% and 86% capture efficiency, respectively. Our proof-of-concept experiments demonstrated that 65% of captured SK-BR-3 cells were released after EDTA treatment, and nearly 70% of released SK-BR-3 cells kept their viability, which may facilitate molecular profiling and functional readouts of CTCs.


Assuntos
Sondas Moleculares , Nanoestruturas , Neoplasias/patologia , Fluorescência , Humanos
16.
Anal Chem ; 85(24): 11929-35, 2013 Dec 17.
Artigo em Inglês | MEDLINE | ID: mdl-24191690

RESUMO

In this study, we report a simple method for simultaneous detection of multiplex DNA sequences, including complementary DNA (cDNA) sequences of HIV and HCV, DNA sequence of HBV, with QDs-encoded fluorescent nanospheres and nano-γ-Fe2O3-coated magnetic nanospheres. Detection was achieved on a fluorescence spectrophotometer without additional auxiliary instruments, and the detection limit was about 100 pM. Here, QDs-encoded fluorescent nanospheres (FNS) with different photoluminescent properties, and magnetic nanospheres (MNS) were separately fabricated by stepwise assembly of hydrophobic QDs or nano-γ-Fe2O3 on the surface of branched poly(ethylene imine) (PEI)-coated nanospheres in precisely controlled amounts, finally followed by silica encapsulation. FNS-labeled probe DNAs and MNS-labeled capture DNAs were used to hybridize with the corresponding targets at the same time. After magnetic separation, the sandwich-structured adducts were measured by fluorescence spectrophotometry. The results indicated that the targets could be detected with high sensitivity. This method is convenient, fast enough, and capable of high anti-interference. Therefore, it is expected to be used for simultaneous detection and separation of multiple targets at high levels of purity and throughput.


Assuntos
DNA/genética , DNA/isolamento & purificação , Nanosferas/química , Fenômenos Ópticos , Espectrometria de Fluorescência/métodos , Sequência de Bases , DNA/sangue , Pontos Quânticos , Fatores de Tempo
17.
Anal Chem ; 85(2): 1223-30, 2013 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-23256523

RESUMO

Sensitive, rapid, and reliable detection of bacteria has always been pursued due to the great threat of the bacteria to human health. In this study, a convenient one-step strategy for detecting Salmonella typhimurium was developed. Immunomagnetic nanospheres (IMNS) and immunofluorescent nanospheres (IFNS) were used to specifically capture and recognize S. typhimurium simultaneously. After magnetic separation, the sandwich immune complexes (IMNS-bacteria-IFNS) were detected under a fluorescence microscope with a detection limit as low as ca. 10 CFU/mL. When they were detected by fluorescence spectrometer, a linear range was exhibited at the concentration from 10(5) to 10(7) CFU/mL with R(2) = 0.9994. Compared with the two-step detection strategy, in which the bacteria were first captured with the IMNS and subsequently identified with the IFNS, this one-step strategy simplified the detection process and improved the sensitivity. Escherichia coli and Shigella flexneri both showed negative results with this method, indicating that this method had excellent selectivity and specificity. Moreover, this method had strong anti-interference ability, and it had been successfully used to detect S. typhimurium in synthetic samples (milk, fetal bovine serum, and urine), showing the potential application in practice.


Assuntos
Fluorescência , Nanopartículas de Magnetita/química , Nanosferas/química , Salmonella typhimurium/isolamento & purificação , Tamanho da Partícula , Salmonella typhimurium/imunologia , Espectrometria de Fluorescência , Propriedades de Superfície
18.
Biosens Bioelectron ; 241: 115688, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-37714062

RESUMO

Traditional lateral flow immunoassays (LFIA) suffer from insufficient sensitivity, difficulty for quantitation, and susceptibility to complex substrates, limiting their practical application. Herein, we developed a polyethylenimine (PEI)-mediated approach for assembling high-density Au nanoshells onto Fe3O4 nanoclusters (MagAushell) as LFIA labels for integrated enrichment and photothermal/colorimetric dual-mode detection of SARS-CoV-2 nucleocapsid protein (N protein). PEI layer served not only as "binders" to Fe3O4 nanoclusters and Au nanoshells, but also "barriers" to ambient environment. Thus, MagAushell not only combined magnetic and photothermal properties, but also showed good stability. With MagAushell, N protein was first separated and enriched from complex samples, and then loaded to the strip for detection. By observation of the color stripes, qualitative detection was performed with naked eye, and by measuring the temperature change under laser irradiation, quantification was attained free of sophisticated instruments. The introduction of Fe3O4 nanoclusters facilitated target purification and enrichment before LFIA, which greatly improved the anti-interference ability and increased the detection sensitivity by 2 orders compared with those without enrichment. Moreover, the high loading density of Au nanoshells on one Fe3O4 nanocluster enhanced the photothermal signal of the nanoprobe significantly, which could further increase the detection sensitivity. The photothermal detection limit reached 43.64 pg/mL which was 1000 times lower than colloidal gold strips. Moreover, this method was successfully applied to real samples, showing great application potential in practice. We envision that this LFIA could serve not only for SARS-CoV-2 detection but also as a general test platform for other biotargets in clinical samples.


Assuntos
Técnicas Biossensoriais , COVID-19 , Nanopartículas Metálicas , Nanoconchas , Humanos , SARS-CoV-2 , Colorimetria , COVID-19/diagnóstico , Proteínas do Nucleocapsídeo , Imunoensaio , Nanopartículas Metálicas/química
19.
Anal Chim Acta ; 1255: 341102, 2023 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-37032051

RESUMO

Although many approaches have been developed for the quick assessment of SARS-CoV-2 infection, few of them are devoted to the detection of the neutralizing antibody, which is essential for assessing the effectiveness of vaccines. Herein, we developed a tri-mode lateral flow immunoassay (LFIA) platform based on gold-silver alloy hollow nanoshells (Au-Ag HNSs) for the sensitive and accurate quantification of neutralizing antibodies. By tuning the shell-to-core ratio, the surface plasmon resonance (SPR) absorption band of the Au-Ag HNSs is located within the near infrared (NIR) region, endowing them with an excellent photothermal effect under the irradiation of optical maser at 808 nm. Further, the Raman reporter molecule 4-mercaptobenzoic acid (MBA) was immobilized on the gold-silver alloy nanoshell to obtain an enhanced SERS signal. Thus, these Au-Ag HNSs could provide colorimetric, photothermal and SERS signals, with which, tri-mode strips for SARS-CoV-2 neutralizing antibody detection were constructed by competitive immunoassay. Since these three kinds of signals could complement one another, a more accurate detection was achieved. The tri-mode LFIA achieved a quantitative detection with detection limit of 20 ng/mL. Moreover, it also successfully detected the serum samples from 98 vaccinated volunteers with 79 positive results, exhibiting great application value in neutralizing antibody detection.


Assuntos
Anticorpos Neutralizantes , COVID-19 , Imunoensaio , Nanoconchas , SARS-CoV-2 , Análise Espectral Raman , Humanos , Ligas , Anticorpos Neutralizantes/imunologia , Anticorpos Neutralizantes/isolamento & purificação , Anticorpos Antivirais/imunologia , Colorimetria/métodos , COVID-19/diagnóstico , COVID-19/imunologia , Ouro , Imunoensaio/instrumentação , Imunoensaio/métodos , Nanopartículas Metálicas , SARS-CoV-2/imunologia , Prata , Análise Espectral Raman/métodos
20.
Talanta ; 256: 124271, 2023 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-36681038

RESUMO

Rapid screening of multiple pathogens will greatly improve the efficiency of pandemic prevention and control. Colorimetric methods exhibit the advantages of convenience, portability, low cost, time efficiency, and free of sophisticated instruments, yet usually have difficulties in simultaneous detection and suffer from monotonous color changes with low visual resolution and sensitivity. Hence, coupled three kinds of plasmonic nanoparticles (NPs) with magnetic separation, we developed an achromatic colorimetric nanosensor with highly enhanced visual resolution for simultaneous detection of SARS-CoV-2, Staphylococcus aureus, and Salmonella typhimurium. The achromatic nanosensor was composed of SARS-CoV-2-targeting red gold NPs, S. aureus-targeting yellow silver NPs and S. typhimurium-targeting blue silver triangle NPs mixed as black color. In the detection, three corresponding magnetic probes were added into the above mixture. In the presence of a target pathogen, it would be recognized and combined with corresponding colored reporters and magnetic probes to form sandwich complexes, which were removed by magnetic separation, and the sensor changed from black to a chromatic color (the color of the reporters remained in supernatant). Consequently, different target pathogen induced different color. For example, SARS-CoV-2, S. aureus, and S. typhimurium respectively produced green, purple, and orange. While coexistence of S. aureus and S. typhimurium produced red, and coexistence of S. aureus and SARS-CoV-2 produced blue, etc. Therefore, by observing the color change or measuring the absorption spectra, multiple pathogen detection was achieved conveniently. Compared with most colorimetric sensors, this achromatic nanosensor involved rich color change, thus significantly enhancing visual resolution and inspection sensitivity. Therefore, this sensor opened a promising avenue for efficient monitoring and early warning of food safety and quality.


Assuntos
COVID-19 , Nanopartículas Metálicas , Nanopartículas , Humanos , Prata , Colorimetria/métodos , Staphylococcus aureus , COVID-19/diagnóstico , SARS-CoV-2 , Ouro , Fenômenos Magnéticos
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa