RESUMO
BACKGROUND: Calmodulinopathies are rare inherited arrhythmia syndromes caused by dominant heterozygous variants in CALM1, CALM2, or CALM3, which each encode the identical CaM (calmodulin) protein. We hypothesized that antisense oligonucleotide (ASO)-mediated depletion of an affected calmodulin gene would ameliorate disease manifestations, whereas the other 2 calmodulin genes would preserve CaM level and function. METHODS: We tested this hypothesis using human induced pluripotent stem cell-derived cardiomyocyte and mouse models of CALM1 pathogenic variants. RESULTS: Human CALM1F142L/+ induced pluripotent stem cell-derived cardiomyocytes exhibited prolonged action potentials, modeling congenital long QT syndrome. CALM1 knockout or CALM1-depleting ASOs did not alter CaM protein level and normalized repolarization duration of CALM1F142L/+ induced pluripotent stem cell-derived cardiomyocytes. Similarly, an ASO targeting murine Calm1 depleted Calm1 transcript without affecting CaM protein level. This ASO alleviated drug-induced bidirectional ventricular tachycardia in Calm1N98S/+ mice without a deleterious effect on cardiac electrical or contractile function. CONCLUSIONS: These results provide proof of concept that ASOs targeting individual calmodulin genes are potentially effective and safe therapies for calmodulinopathies.
Assuntos
Calmodulina , Miócitos Cardíacos , Oligonucleotídeos Antissenso , Animais , Calmodulina/genética , Calmodulina/metabolismo , Oligonucleotídeos Antissenso/uso terapêutico , Oligonucleotídeos Antissenso/farmacologia , Humanos , Miócitos Cardíacos/metabolismo , Camundongos , Células-Tronco Pluripotentes Induzidas/metabolismo , Síndrome do QT Longo/genética , Síndrome do QT Longo/tratamento farmacológico , Síndrome do QT Longo/terapia , Síndrome do QT Longo/fisiopatologia , Modelos Animais de Doenças , Potenciais de Ação/efeitos dos fármacos , Camundongos Knockout , Terapia Genética/métodosRESUMO
Pediatric Hypertrophic Cardiomyopathy (HCM) is associated with sudden cardiac death (SCD) that can be related to physical activity. Without pediatric specific guidelines, recommendations for activity restriction may be varied. Therefore, our aim is to determine the current practice and variability surrounding exercise clearance recommendations (ER) in pediatric HCM referral centers as well as provider and patient characteristics that influence them. We designed a survey that was distributed to the Pediatric Heart Transplant Study (PHTS) providers and members of the Pediatric and Adult Congenital Electrophysiology Society (PACES) querying provider demographics and patient variables from 2 patient vignettes. The study is a multicenter survey of current practice of specialized providers caring for pediatric HCM patients. Survey of PHTS and PACES providers via email to the respective listservs with a response rate of 28% and 91 overall completing the entire survey after self-identifying as providers for pediatric HCM patients at their center. ER varies for pediatric HCM and is associated with provider training background as well as personal and professional history. Of the 91 providers who completed the survey, 42% (N = 38) trained in pediatric electrophysiology (EP), and 40% (N = 36) in pediatric heart failure (HF). Responses varied and only 53% of providers cleared for mild to moderate activity for the patient in Vignette 1, which is more in line with recent published adult guidelines. ER in both vignettes was significantly associated with type of training background. EP providers were more likely to recommend no restriction (27.8% vs 5.9%) than HF providers even when controlling for provider age and time out of training. Syncope with exercise was deemed "Most Important" by 81% of providers when making ER. ER for pediatric HCM are variable and the majority of providers make ER outside of previously published adult guidelines. Furthermore, ER are influenced by provider background and experience. Further study is needed for risks and benefits of physical activity in this population to inform the development of pediatric specific guidelines.
Assuntos
Cardiomiopatia Hipertrófica , Insuficiência Cardíaca , Adulto , Cardiomiopatia Hipertrófica/terapia , Criança , Morte Súbita Cardíaca , Exercício Físico , Humanos , Inquéritos e QuestionáriosRESUMO
BACKGROUND: Hypertrophic cardiomyopathy is the leading cause of sudden cardiac death (SCD) in children and young adults. Our objective was to develop and validate a SCD risk prediction model in pediatric hypertrophic cardiomyopathy to guide SCD prevention strategies. METHODS: In an international multicenter observational cohort study, phenotype-positive patients with isolated hypertrophic cardiomyopathy <18 years of age at diagnosis were eligible. The primary outcome variable was the time from diagnosis to a composite of SCD events at 5-year follow-up: SCD, resuscitated sudden cardiac arrest, and aborted SCD, that is, appropriate shock following primary prevention implantable cardioverter defibrillators. Competing risk models with cause-specific hazard regression were used to identify and quantify clinical and genetic factors associated with SCD. The cause-specific regression model was implemented using boosting, and tuned with 10 repeated 4-fold cross-validations. The final model was fitted using all data with the tuned hyperparameter value that maximizes the c-statistic, and its performance was characterized by using the c-statistic for competing risk models. The final model was validated in an independent external cohort (SHaRe [Sarcomeric Human Cardiomyopathy Registry], n=285). RESULTS: Overall, 572 patients met eligibility criteria with 2855 patient-years of follow-up. The 5-year cumulative proportion of SCD events was 9.1% (14 SCD, 25 resuscitated sudden cardiac arrests, and 14 aborted SCD). Risk predictors included age at diagnosis, documented nonsustained ventricular tachycardia, unexplained syncope, septal diameter z-score, left ventricular posterior wall diameter z score, left atrial diameter z score, peak left ventricular outflow tract gradient, and presence of a pathogenic variant. Unlike in adults, left ventricular outflow tract gradient had an inverse association, and family history of SCD had no association with SCD. Clinical and clinical/genetic models were developed to predict 5-year freedom from SCD. Both models adequately discriminated between patients with and without SCD events with a c-statistic of 0.75 and 0.76, respectively, and demonstrated good agreement between predicted and observed events in the primary and validation cohorts (validation c-statistic 0.71 and 0.72, respectively). CONCLUSION: Our study provides a validated SCD risk prediction model with >70% prediction accuracy and incorporates risk factors that are unique to pediatric hypertrophic cardiomyopathy. An individualized risk prediction model has the potential to improve the application of clinical practice guidelines and shared decision making for implantable cardioverter defibrillator insertion. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT0403679.
Assuntos
Cardiomiopatia Hipertrófica/epidemiologia , Morte Súbita Cardíaca/epidemiologia , Modelos Estatísticos , Adolescente , Fatores Etários , Algoritmos , Cardiomiopatia Hipertrófica/complicações , Criança , Morte Súbita Cardíaca/etiologia , Feminino , Humanos , Masculino , Vigilância em Saúde Pública , Reprodutibilidade dos Testes , Estudos Retrospectivos , Medição de Risco , Fatores de RiscoRESUMO
BACKGROUND: Pediatric and congenital heart disease (CHD) patients have a high rate of transvenous (TV) lead failure. OBJECTIVE: To determine whether TV lead age can aid risk assessment for lead failure to guide the decision of whether a lead should be replaced or reused at the time of a generator change. METHODS: Retrospective cohort study of patients <21 years old undergoing TV device implant from 2000 to 2014 at our institution. Patient, device, and lead variables were collected. Leads were compared in groups based on how many generator changes were completed. RESULTS: A total of 393 leads in 257 patients met inclusion criteria, 60 leads failed (15%). Failed leads were more likely to have not yet undergone generator change (p = .048). CHD (p = .045), Tendril lead type (p = .02) and silicone insulation (p = .02) were associated with failure. In multivariate analysis, younger leads (p = .022), number of generator changes (p = .003), CHD (p = .005) and silicone insulation (p = .004) remained significant while Tendril lead type did not (p = .052). Survival curves show an early decline around 4 years. CONCLUSIONS: Lead failure rate in pediatric and CHD patients is high. Leads that have not yet undergone a generator change were more likely to fail in this cohort. The strategy of serial replacement based on lead age needs further research to justify in this population.
Assuntos
Eletrodos Implantados/efeitos adversos , Análise de Falha de Equipamento , Cardiopatias Congênitas/terapia , Procedimentos Cirúrgicos Cardíacos , Criança , Desfibriladores Implantáveis , Remoção de Dispositivo , Feminino , Humanos , Masculino , Marca-Passo Artificial , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Adulto JovemRESUMO
BACKGROUND: Infants with complete heart block (CHB) require epicardial pacemaker (PM) insertion. Prior studies described epicardial pacing outcomes in infants and children, although they were limited by small or heterogeneous populations. OBJECTIVE: This study aimed to explore patient- and procedure-level associations with device complications in infants with CHB who received a permanent PM. METHODS: This was a multicenter, retrospective cohort study including infants receiving an epicardial PM between 2000 and 2021 for CHB. The primary outcome was time to device-related adverse event: lead failure requiring revision; pocket infection; exit block requiring increased pacing output; or lead-related coronary artery compression. Time-to-event analysis was performed by the Kaplan-Meier method with a multivariable Cox proportional hazards model. RESULTS: There were 174 infants who received an epicardial PM (282 bipolar, 39 unipolar leads) for CHB. Median age and weight at PM were 93.5 days and 4.5 kg, respectively. Pacing indication was postoperative CHB in 63% and congenital CHB in 37%. The median follow-up was 2.1 years. The primary outcome occurred in 26 infants at a median time to event of 0.6 year. Age ≤90 days at PM implantation was the most significant risk factor for a device-related adverse event (hazard ratio, 7.02; P < .001), primarily driven by pocket infections. Lead failure occurred in 3% of leads with a 5- and 10-year freedom from failure of 93% and 83%, respectively. CONCLUSION: Device complications affect 15% of infants receiving a permanent PM for heart block. Age ≤90 days at PM implantation is especially associated with infectious complications. Epicardial lead durability appears similar to previously reported pediatric experiences.
RESUMO
BACKGROUND: Junctional ectopic tachycardia (JET) complicates congenital heart surgery in 2% to 8.3% of cases. JET is associated with postoperative morbidity in single-center studies. We used the Pediatric Cardiac Critical Care Consortium data registry to provide a multicenter epidemiologic description of treated JET. METHODS: This is a retrospective study (February 2019-August 2022) of patients with treated JET. Inclusion criteria were (1) <12 months old at the index operation, and (2) treated for JET <72 hours after surgery. Diagnosis was defined by receiving treatment (pacing, cooling, and medications). A multilevel logistic regression analysis with hospital random effect identified JET risk factors. Impact of JET on outcomes was estimated by margins/attributable risk analysis using previous risk-adjustment models. RESULTS: Among 24,073 patients from 63 centers, 1436 (6.0%) were treated for JET with significant center variability (0% to 17.9%). Median time to onset was 3.4 hours, with 34% present on admission. Median duration was 2 days (interquartile range, 1-4 days). Tetralogy of Fallot, atrioventricular canal, and ventricular septal defect repair represented >50% of JET. Patient characteristics independently associated with JET included neonatal age, Asian race, cardiopulmonary bypass time, open sternum, and early postoperative inotropic agents. JET was associated with increased risk-adjusted durations of mechanical ventilation (incidence rate ratio, 1.6; 95% CI, 1.5-1.7) and intensive care unit length of stay (incidence rate ratio, 1.3; 95% CI, 1.2-1.3), but not mortality. CONCLUSIONS: JET is treated in 6% of patients with substantial center variability. JET contributes to increased use of postoperative resources. High center variability warrants further study to identify potential modifiable factors that could serve as targets for improvement efforts to ameliorate deleterious outcomes.
Assuntos
Procedimentos Cirúrgicos Cardíacos , Cardiopatias Congênitas , Complicações Pós-Operatórias , Taquicardia Ectópica de Junção , Humanos , Taquicardia Ectópica de Junção/epidemiologia , Taquicardia Ectópica de Junção/etiologia , Estudos Retrospectivos , Lactente , Feminino , Masculino , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Complicações Pós-Operatórias/epidemiologia , Cardiopatias Congênitas/cirurgia , Recém-Nascido , Incidência , Fatores de Risco , Estados Unidos/epidemiologiaRESUMO
BACKGROUND: Atrial standstill (AS) is a rare condition characterized by absence of electrical activity within the atria. Studies to date have been limited. OBJECTIVES: The authors sought to describe the clinical characteristics, genetics, and outcomes of patients with AS. METHODS: This was a retrospective multicenter study of patients <18 years at AS diagnosis, defined as absence of atrial activity documented during an electrophysiology study, device placement, or noninvasive rhythm tracings and confirmed by echocardiogram. Patients with acquired disorders were excluded. Clinical details and genetic variants were recorded and analyzed. RESULTS: Twenty patients were diagnosed at a median age of 6.6 years (IQR: 2.9-10.8 years). Arrhythmias included 16 (80%) with atrial/supraventricular arrhythmias and 8 (40%) with ventricular tachycardia, including 4 with cardiac arrests. A type 1 Brugada pattern was documented in 4. Pacemakers were implanted in 18 (90%). Although atrial leads were attempted in 15, only 4 achieved pacing at implantation. During a median follow-up of 6.9 years (IQR: 1.2-13.3 years), 7 (35%) had thromboembolic events. Of these, none had atrial pacing, 6 were not on anticoagulation, and 1 was on aspirin. Genetic testing identified SCN5A variants in 13 patients (65%). Analyses suggest SCN5A loss-of-function may be one mechanism driving AS. Ventricular arrhythmias and cardiac arrest were more commonly seen in patients with biallelic SCN5A variants. CONCLUSIONS: AS may be associated with loss-of-function SCN5A variants. Patients demonstrate atrial and ventricular arrhythmias, and may present challenges during device placement. Patients without the capacity for atrial pacing are at risk for thromboembolic events and warrant anticoagulation.
Assuntos
Fibrilação Atrial , Parada Cardíaca , Humanos , Criança , Pré-Escolar , Átrios do Coração/diagnóstico por imagem , Bloqueio Cardíaco , AnticoagulantesRESUMO
BACKGROUND: Transcatheter Leadless Pacemakers (TLP) are a safe and effective option for adults with pacing indications. These devices may be an alternative in pediatric patients and patients with congenital heart disease for whom repeated sternotomies, thoracotomies, or transvenous systems are unfavorable. However, exemption of children from clinical trials has created uncertainty over the indications, efficacy, and safety of TLP in the pediatric population. The objectives of this study are to evaluate clinical indications, procedural characteristics, electrical performance, and outcomes of TLP implantation in children. METHODS: Retrospective data were collected from patients enrolled in the Pediatric and Congenital Electrophysiology Society TLP registry involving 15 centers. Patients ≤21 years of age who underwent Micra (Medtronic Inc, Minneapolis, MN) TLP implantation and had follow-up of ≥1 week were included in the study. RESULTS: The device was successfully implanted in 62 of 63 registry patients (98%) at a mean age of 15±4.1 years and included 20 (32%) patients with congenital heart disease. The mean body weight at TLP implantation was 55±19 kg and included 8 patients ≤8 years of age and ≤30 kg in weight. TLP was implanted by femoral (n=55, 87%) and internal jugular (n=8, 12.6%) venous approaches. During a mean follow-up period of 9.5±5.3 months, there were 10 (16%) complications including one cardiac perforation/pericardial effusion, one nonocclusive femoral venous thrombus, and one retrieval and replacement of TLP due to high thresholds. There were no deaths, TLP infections, or device embolizations. Electrical parameters, including capture thresholds, R wave sensing, and pacing impedances, remained stable. CONCLUSIONS: Initial results from the Pediatric and Congenital Electrophysiology Society TLP registry demonstrated a high level of successful Micra device implants via femoral and internal venous jugular approaches with stable electrical parameters and infrequent major complications. Long-term prospective data are needed to confirm the reproducibility of these initial findings.
Assuntos
Cardiopatias Congênitas , Marca-Passo Artificial , Adulto , Humanos , Criança , Adolescente , Adulto Jovem , Recém-Nascido , Estudos Prospectivos , Estudos Retrospectivos , Reprodutibilidade dos Testes , Resultado do Tratamento , Desenho de Equipamento , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Cardiopatias Congênitas/diagnóstico , Cardiopatias Congênitas/terapiaRESUMO
The Norwood procedure with a right ventricular to pulmonary artery shunt (RVPAS) decreases early mortality, but requires a ventriculotomy, possibly increasing risk of ventricular arrhythmias (VAs) compared with the modified Blalock-Taussig shunt (MBTS). The effect of shunt and Fontan type on arrhythmias by 6 years of age in the SVRII (Single Ventricle Reconstruction Extension Study) was assessed. SVRII data collected on 324 patients pre-/post-Fontan and annually at 2 to 6 years included antiarrhythmic medications, electrocardiography (ECG) at Fontan, and Holter/ECG at 6 years. ECGs and Holters were reviewed for morphology, intervals, atrioventricular conduction, and arrhythmias. Isolated VA were seen on 6-year Holter in >50% of both cohorts (MBTS 54% vs RVPAS 60%), whereas nonsustained ventricular tachycardia was rare and observed in RVPAS only (2.7%). First-degree atrioventricular block was more common in RVPAS than MBTS (21% vs 8%, pâ¯=â¯0.01), whereas right bundle branch block, QRS duration, and QTc were similar. Antiarrhythmic medication usage was common in both groups, but most agents also supported ventricular function (e.g., digoxin, carvedilol). Of the 7 patients with death or transplant between 2 and 6 years, none had documented VAs, but compared with transplant-free survivors, they had somewhat longer QRS (106 vs 93 ms, pâ¯=â¯0.05). Atrial tachyarrhythmias varied little between MBTS and RVPAS but did vary by Fontan type (lateral tunnel 41% vs extracardiac conduit 29%). VAs did not vary by Fontan type. In conclusion, at 6-year follow-up, benign VAs were common in the SVRII population. However, despite the potential for increased VAs and sudden death in the RVPAS cohort, these data do not support significant differences or increased risk at 6 years. The findings highlight the need for ongoing surveillance for arrhythmias in the SVR population.
Assuntos
Procedimento de Blalock-Taussig , Síndrome do Coração Esquerdo Hipoplásico , Procedimentos de Norwood , Arritmias Cardíacas/epidemiologia , Procedimento de Blalock-Taussig/efeitos adversos , Ensaios Clínicos como Assunto , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/cirurgia , Humanos , Síndrome do Coração Esquerdo Hipoplásico/cirurgia , Procedimentos de Norwood/efeitos adversos , Procedimentos de Norwood/métodos , Artéria Pulmonar , Resultado do TratamentoRESUMO
BACKGROUND: Sotalol is an important antiarrhythmic drug in the pediatric population. Given the risk of proarrhythmia, sotalol is initiated in inpatient settings, with adult studies as recent as 2015 supporting this practice. OBJECTIVE: The purpose of this study was to determine the frequency of adverse events (AEs) during sotalol initiation for the management of atrial, supraventricular, or ventricular arrhythmias in pediatric patients. METHODS: A retrospective cohort analysis of pediatric patients 21 years or younger initiated on oral sotalol for supraventricular tachycardia or ventricular tachycardia (VT) at Boston Children's Hospital from January 1, 2007, through July 1, 2016, was performed. The primary end point was an AE defined as significant bradycardia, new or increased ventricular arrhythmias, conduction block, or corrected QT interval (QTc) prolongation, resulting in dose reduction or cessation. RESULTS: There were 190 patients who met inclusion criteria, with 110 patients (58%) 6 months or younger. A total of 115 patients (60%) had congenital heart disease. Arrhythmias for which sotalol was initiated included atrioventricular reciprocating tachycardia/atrioventricular nodal reciprocating tachycardia (n = 105 [55%]), atrial flutter (n = 31 [16%]), ectopic atrial tachycardia (n = 26 [14%]), VT (n = 21 [11%]), and atrial fibrillation (n = 7 [4%]). The median pre-sotalol QTc was 438 ms (interquartile range 348-530 ms). Five patients (3%) (aged 0.1-18 years) had AEs including bradycardia <40 beats/min (n = 2) and <100 beats/min (n = 1) and QTc prolongation (n = 2). All 5 patients with AEs had repaired congenital heart disease. CONCLUSION: The incidence of AEs in pediatric patients initiating sotalol for atrial tachycardia, supraventricular tachycardia, or VT is low (3%), with no deaths or malignant rhythms reported in this series.