Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Semin Spine Surg ; : 100961, 2022 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-35574250

RESUMO

Quality improvement has become a foundation of neonatal care. Structured approaches to improvement can standardize practices, improve teamwork, engage families, and improve outcomes. The delivery room presents a unique environment for quality improvement; optimal delivery room care requires advanced preparation, adequately trained providers, and carefully coordinated team dynamics. In this article, we examine quality improvement for neonatal resuscitation. We review the published literature, focusing on reports targeting admission hypothermia, delayed cord clamping, and initial respiratory support. We discuss specific challenges related to delivery room quality improvement, including small numbers, data collection, and lack of benchmarking, and potential strategies to address them including simulation, checklists, and state and national collaboratives. We examine how quality improvement can target equity in delivery room outcomes, and explore the impact of the COVID-19 pandemic on delivery room quality of care.

3.
J Perinatol ; 2024 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-38467745

RESUMO

OBJECTIVES: To assess respiratory care guidelines and explore variations in management of very low birth weight (VLBW) infants within a collaborative care framework. Additionally, to gather clinical leaders' perspectives on guidelines and preferences for ventilation modalities. STUDY DESIGN: Leaders from each NICU participated in a practice survey regarding the prevalence of unit clinical guidelines, and management, at many stages of care. RESULTS: Units have an average of 4.3 (±2.1) guidelines, of 9 topics queried. Guideline prevalence was not associated with practice or outcomes. An FiO2 requirement of 0.3-0.4 and a CPAP of 6-7 cmH2O, are the most common thresholds for surfactant administration, which is most often done after intubation, and followed by weaning from ventilatory support. Volume targeted ventilation is commonly used. Extubation criteria vary widely. CONCLUSIONS: Results identify trends and areas of variation and suggest that the presence of guidelines alone is not predictive of outcome.

4.
J Perinatol ; 44(7): 1001-1008, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38589537

RESUMO

OBJECTIVES: The authors sought to measure and compare practice preference variation in neonatal respiratory care within and between neonatal intensive care units (NICUs) using the Neonatology Survey of Interdisciplinary Groups in Healthcare Tool (NSIGHT). STUDY DESIGN: Eleven NICUs completed the NSIGHT between 2019 and 2021. Net preference was measured by mean response; agreement was ranked by standard distribution of response values. Heat maps showed comparisons between NICUs and disciplines. RESULTS: NICUs and individuals agreed most often on use of pressure support with mandatory ventilation and on use of non-invasive positive pressure ventilation for apnea. High preference variation surrounded decisions for invasive ventilation versus continuous positive airway pressure for extremely low birth weight infants. Preference difference was most frequent between neonatologists and nurses. CONCLUSIONS: Patterns of practice preference variation in neonatal respiratory care are specific to clinical scenario. Measuring preference variation may inform psychology of change and strengthen quality improvement efforts.


Assuntos
Unidades de Terapia Intensiva Neonatal , Melhoria de Qualidade , Humanos , Recém-Nascido , Unidades de Terapia Intensiva Neonatal/normas , Padrões de Prática Médica/estatística & dados numéricos , Neonatologia/normas , Síndrome do Desconforto Respiratório do Recém-Nascido/terapia , Inquéritos e Questionários , Pressão Positiva Contínua nas Vias Aéreas
5.
BMJ Open Qual ; 12(4)2023 12 14.
Artigo em Inglês | MEDLINE | ID: mdl-38101811

RESUMO

BACKGROUND: Understanding behavioural psychology and the human side of change are guiding principles for quality improvement (QI). Tools to measure these to guide improvement efforts are lacking. METHODS: We created a clinical vignette-based survey to measure provider preferences for respiratory care in the neonatal intensive care unit. Fourteen vignettes were included, each vignette offering two reasonable practice choices. Responses were based on a 5-point Likert scale, ranging from neutral to strong preference for either choice. The survey was completed by physicians, nurses, advanced practice providers and respiratory therapists in 2017 and again in 2019. Net preference was measured as the median value of responses, and agreement was measured as the SD of responses. Net preference and agreement were assessed for all responses, by discipline, and by year. RESULTS: Response rates were 51% of all staff in 2017 and 57% in 2019. Vignettes asking about non-invasive respiratory support showed more defined net preferences and higher agreement between years, coinciding with QI efforts and guideline implementation in this area during the interval time. Results on other areas of practice were consistent between years. Discipline comparisons showed nurses and physicians agreed the least often. Six response patterns were identified, ranging from net preference and high agreement to no net preference and low agreement. CONCLUSION: We propose this survey, called the Neonatology Survey of Interdisciplinary Groups in Healthcare Tool, is a novel method for measurement of hospital unit psychology and culture. Demonstrated improvement where QI efforts were focused and consistency in results in other areas support the validity of this tool. Measuring the human side of change may impact QI efforts.


Assuntos
Neonatologia , Médicos , Recém-Nascido , Humanos , Melhoria de Qualidade , Inquéritos e Questionários , Atitude do Pessoal de Saúde
6.
Semin Perinatol ; 46(6): 151629, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35753831

RESUMO

Quality improvement has become a foundation of neonatal care. Structured approaches to improvement can standardize practices, improve teamwork, engage families, and improve outcomes. The delivery room presents a unique environment for quality improvement; optimal delivery room care requires advanced preparation, adequately trained providers, and carefully coordinated team dynamics. In this article, we examine quality improvement for neonatal resuscitation. We review the published literature, focusing on reports targeting admission hypothermia, delayed cord clamping, and initial respiratory support. We discuss specific challenges related to delivery room quality improvement, including small numbers, data collection, and lack of benchmarking, and potential strategies to address them including simulation, checklists, and state and national collaboratives. We examine how quality improvement can target equity in delivery room outcomes, and explore the impact of the COVID-19 pandemic on delivery room quality of care.


Assuntos
COVID-19 , Ressuscitação , COVID-19/epidemiologia , COVID-19/terapia , Salas de Parto , Feminino , Humanos , Recém-Nascido , Pandemias , Gravidez , Melhoria de Qualidade
8.
Neoreviews ; 19(8): e490-e492, 2022 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-35878402
9.
J Immunol ; 177(10): 6999-7006, 2006 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-17082615

RESUMO

Cytokine production is associated with both the normal and pathologic inflammatory response to injury. Previous studies have shown that the immunosuppressants cyclosporin A or FK506, which interact with the peptidyl-propyl isomerases cyclophilin A and FK506-binding protein (FKBP12), respectively, block cytokine expression. A third member of the peptidyl-propyl isomerase family, Pin1 is expressed by immune and other cells. Pin1 has been implicated in cell cycle progression, is overexpressed in human tumors, and may rescue neurons from tau-associated degeneration. However, the role of Pin1 in the immune system remains largely unknown. In this study, we analyze the role of Pin1 in GM-CSF expression by human PBMC and CD4+ lymphocytes. We show that Pin1 isomerase activity is necessary for activation-dependent, GM-CSF mRNA stabilization, accumulation, and protein secretion, but not non-AU-rich elements containing cytokine mRNAs, including TGF-beta and IL-4. Mechanistically, Pin1 mediated the association of the AU-rich element-binding protein, AUF1, with GM-CSF mRNA, which determined the rate of decay by the exosome.


Assuntos
Linfócitos T CD4-Positivos/enzimologia , Fator Estimulador de Colônias de Granulócitos e Macrófagos/genética , Fator Estimulador de Colônias de Granulócitos e Macrófagos/metabolismo , Peptidilprolil Isomerase/fisiologia , Estabilidade de RNA , RNA Mensageiro/metabolismo , Linfócitos T CD4-Positivos/imunologia , Linfócitos T CD4-Positivos/metabolismo , Citocinas/biossíntese , Fator Estimulador de Colônias de Granulócitos e Macrófagos/biossíntese , Humanos , Leucócitos Mononucleares/enzimologia , Leucócitos Mononucleares/imunologia , Leucócitos Mononucleares/metabolismo , Ativação Linfocitária/genética , Peptidilprolil Isomerase de Interação com NIMA , Estabilidade de RNA/imunologia , Regulação para Cima
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa