Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 613
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
N Engl J Med ; 389(16): 1466-1476, 2023 Oct 19.
Artigo em Inglês | MEDLINE | ID: mdl-37634188

RESUMO

BACKGROUND: Data regarding clinical outcomes after optical coherence tomography (OCT)-guided percutaneous coronary intervention (PCI) as compared with angiography-guided PCI are limited. METHODS: In this prospective, randomized, single-blind trial, we randomly assigned patients with medication-treated diabetes or complex coronary-artery lesions to undergo OCT-guided PCI or angiography-guided PCI. A final blinded OCT procedure was performed in patients in the angiography group. The two primary efficacy end points were the minimum stent area after PCI as assessed with OCT and target-vessel failure at 2 years, defined as a composite of death from cardiac causes, target-vessel myocardial infarction, or ischemia-driven target-vessel revascularization. Safety was also assessed. RESULTS: The trial was conducted at 80 sites in 18 countries. A total of 2487 patients underwent randomization: 1233 patients were assigned to undergo OCT-guided PCI, and 1254 to undergo angiography-guided PCI. The minimum stent area after PCI was 5.72±2.04 mm2 in the OCT group and 5.36±1.87 mm2 in the angiography group (mean difference, 0.36 mm2; 95% confidence interval [CI], 0.21 to 0.51; P<0.001). Target-vessel failure within 2 years occurred in 88 patients in the OCT group and in 99 patients in the angiography group (Kaplan-Meier estimates, 7.4% and 8.2%, respectively; hazard ratio, 0.90; 95% CI, 0.67 to 1.19; P = 0.45). OCT-related adverse events occurred in 1 patient in the OCT group and in 2 patients in the angiography group. Stent thrombosis within 2 years occurred in 6 patients (0.5%) in the OCT group and in 17 patients (1.4%) in the angiography group. CONCLUSIONS: Among patients undergoing PCI, OCT guidance resulted in a larger minimum stent area than angiography guidance, but there was no apparent between-group difference in the percentage of patients with target-vessel failure at 2 years. (Funded by Abbott; ILUMIEN IV: OPTIMAL PCI ClinicalTrials.gov number, NCT03507777.).


Assuntos
Angiografia Coronária , Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Tomografia de Coerência Óptica , Humanos , Angiografia Coronária/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/etiologia , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Estudos Prospectivos , Método Simples-Cego , Tomografia de Coerência Óptica/métodos , Resultado do Tratamento , Diabetes Mellitus , Implante de Prótese Vascular/métodos , Stents
2.
Artigo em Inglês | MEDLINE | ID: mdl-38922547

RESUMO

PURPOSE: In Ireland, over 3000 patients are diagnosed with breast cancer annually, and 1 in 9 Irish women will be diagnosed with breast cancer in their lifetime. There is evidence that female breast cancer survivors are more likely to die of cardiovascular disease than their age-matched counterparts. Specific services for cancer patients suffering from cancer therapy related cardiovascular toxicity have led to a higher incidence of safe anti-cancer treatment completion. Such services are not widely available in our jurisdiction, and the purpose of this trial is to remedy this situation. METHODS: This protocol describes a prospective, single arm, pilot feasibility study implementing a dedicated Cardio-Oncology assessment and surveillance pathway for patients receiving multimodal breast cancer treatment. It incorporates novel biomarker and radiomic surveillance and monitoring approaches for cancer-therapy related cardiac dysfunction into routine care for breast cancer patients undergoing adjuvant systemic chemotherapy. RESULTS: Declaration of results will via peer reviewed academic journals, and communicated directly to key knowledge users both nationally and internationally. This engagement will be critical to enable to healthcare services and policy sector make informed decisions or valuable changes to clinical practice, expenditure and/or systems development to support specialized Cardio-Oncology clinical pathways. All data is to be made available upon request. CONCLUSION: Dedicated cardio-oncology services have been recommended in recent literature to improve patient outcomes. Our protocol describes a feasibility study into the provision of such services for breast cancer.

3.
Eur Heart J ; 44(41): 4324-4336, 2023 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-37188864

RESUMO

AIMS: The present study sought to determine the rate and prognostic implications of post-procedural physiologically significant residual ischemia according to Murray law-based quantitative flow ratio (µQFR) after left main (LM) bifurcation percutaneous coronary intervention (PCI). METHODS AND RESULTS: Consecutive patients undergoing LM bifurcation stenting at a large tertiary care center between January 2014 and December 2016 with available post-PCI µQFR were included. Physiologically significant residual ischemia was defined by post-PCI µQFR values ≤0.80 in the left anterior descending (LAD) or left circumflex artery (LCX). The primary outcome was 3-year cardiovascular death. The major secondary outcome was 3-year bifurcation-oriented composite endpoint (BOCE). Among 1170 included patients with analyzable post-PCI µQFR, 155 (13.2%) had residual ischemia in either LAD or LCX. Patients with vs. those without residual ischemia had a higher risk of 3-year cardiovascular mortality [5.4% vs. 1.3%; adjusted hazard ratio (HR) 3.20, 95% confidence interval (CI): 1.16-8.80]. The 3-year risk of BOCE was significantly higher in the residual ischemia group (17.8% vs. 5.8%; adjusted HR 2.79, 95% CI: 1.68-4.64), driven by higher incidence of the composite of cardiovascular death and target bifurcation-related myocardial infarction (14.0% vs. 3.3%; adjusted HR 4.06, 95% CI: 2.22-7.42). A significant, inverse association was observed between continuous post-PCI µQFR and the risk of clinical outcomes (per 0.1 µQFR decrease, HR of cardiovascular death 1.27, 95% CI: 1.00-1.62; HR of BOCE 1.29, 95% CI: 1.14-1.47). CONCLUSION: After angiographically successful LM bifurcation PCI, residual ischemia assessed by µQFR was identified in 13.2% of patients and was associated with higher risk of 3-year cardiovascular death, indicating the superior prognostic value of post-PCI physiological assessment.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Infarto do Miocárdio , Intervenção Coronária Percutânea , Humanos , Doença da Artéria Coronariana/complicações , Intervenção Coronária Percutânea/métodos , Resultado do Tratamento , Stents Farmacológicos/efeitos adversos , Angiografia Coronária/métodos
4.
Eur Heart J ; 44(15): 1313-1330, 2023 04 17.
Artigo em Inglês | MEDLINE | ID: mdl-36790101

RESUMO

Since the publication of the 2018 European Society of Cardiology/European Society of Hypertension (ESC/ESH) Guidelines for the Management of Arterial Hypertension, several high-quality studies, including randomised, sham-controlled trials on catheter-based renal denervation (RDN) were published, confirming both the blood pressure (BP)-lowering efficacy and safety of radiofrequency and ultrasound RDN in a broad range of patients with hypertension, including resistant hypertension. A clinical consensus document by the ESC Council on Hypertension and the European Association of Percutaneous Cardiovascular Interventions (EAPCI) on RDN in the management of hypertension was considered necessary to inform clinical practice. This expert group proposes that RDN is an adjunct treatment option in uncontrolled resistant hypertension, confirmed by ambulatory BP measurements, despite best efforts at lifestyle and pharmacological interventions. RDN may also be used in patients who are unable to tolerate antihypertensive medications in the long term. A shared decision-making process is a key feature and preferably includes a patient who is well informed on the benefits and limitations of the procedure. The decision-making process should take (i) the patient's global cardiovascular (CV) risk and/or (ii) the presence of hypertension-mediated organ damage or CV complications into account. Multidisciplinary hypertension teams involving hypertension experts and interventionalists evaluate the indication and facilitate the RDN procedure. Interventionalists require expertise in renal interventions and specific training in RDN procedures. Centres performing these procedures require the skills and resources to deal with potential complications. Future research is needed to address open questions and investigate the impact of BP-lowering with RDN on clinical outcomes and potential clinical indications beyond hypertension.


Assuntos
Hipertensão , Artéria Renal , Humanos , Adulto , Hipertensão/cirurgia , Hipertensão/tratamento farmacológico , Rim/irrigação sanguínea , Pressão Sanguínea , Anti-Hipertensivos/uso terapêutico , Anti-Hipertensivos/farmacologia , Denervação/métodos , Resultado do Tratamento , Simpatectomia/métodos
5.
Eur Heart J ; 44(41): 4340-4356, 2023 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-37208199

RESUMO

Since the publication of the 2015 EAPCI consensus on rotational atherectomy, the number of percutaneous coronary interventions (PCI) performed in patients with severely calcified coronary artery disease has grown substantially. This has been prompted on one side by the clinical demand for the continuous increase in life expectancy, the sustained expansion of the primary PCI networks worldwide, and the routine performance of revascularization procedures in elderly patients; on the other side, the availability of new and dedicated technologies such as orbital atherectomy and intravascular lithotripsy, as well as the optimization of the rotational atherectomy system, has increased operators' confidence in attempting more challenging PCI. This current EAPCI clinical consensus statement prepared in collaboration with the EURO4C-PCR group describes the comprehensive management of patients with heavily calcified coronary stenoses, starting with how to use non-invasive and invasive imaging to assess calcium burden and inform procedural planning. Objective and practical guidance is provided on the selection of the optimal interventional tool and technique based on the specific calcium morphology and anatomic location. Finally, the specific clinical implications of treating these patients are considered, including the prevention and management of complications and the importance of adequate training and education.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Intervenção Coronária Percutânea , Calcificação Vascular , Humanos , Idoso , Intervenção Coronária Percutânea/métodos , Cálcio , Calcificação Vascular/terapia , Doença da Artéria Coronariana/terapia , Estenose Coronária/terapia , Reação em Cadeia da Polimerase , Resultado do Tratamento , Angiografia Coronária
6.
Am Heart J ; 261: 35-44, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36931370

RESUMO

BACKGROUND: Large-scale registries can provide valuable complementary data to randomized controlled trials (RCT) for the postmarketing evaluation of coronary stents, but their scientific relevance remains debated. METHODS: We sought to compare the evidence on the performance of a single coronary stent platform generated by the RCT for its regulatory approval and a well-conducted international registry. Patients treated with the Ultimaster coronary stent in the CENTURY II (CII-UM) trial (n = 551) were compared to patients in the real-world e-ULTIMASTER (e-UM) registry (n = 35,389). All major events were adjudicated by an independent clinical event committee in both studies. Propensity weighted analysis was used to balance baseline and procedural differences between the 2 populations. RESULTS: Coronary artery disease was more complex in e-UM compared to CII-UM, including more acute coronary syndromes, multivessel disease, left main, arterial, or venous grafts, and chronic total occlusions (P < .005 for all). At one-year follow-up and after excluding periprocedural myocardial infarction (MI) there was no statistically significant difference between CII-UM and e-UM regarding all-cause death (hazard ratio [HR] 0.55, 95% confidence interval [CI] 0.26-1.20, P = .14), cardiac death (HR 0.71, 95% CI 0.29-1.72, P = .45), target lesion failure (HR 1.18, 95% CI 0.78-1.78, P = .44), and target vessel MI (HR 0.76, 95% CI 0.24-2.38, P = .63). However, target vessel revascularization rate was significantly higher in CII-UM than in e-UM, HR 1.78, 95% CI 1.23-2.56, P = .002. CONCLUSIONS: A well-conducted large-scale registry can provide valuable complementary evidence to RCTs on the postmarket performance of new coronary stents, across a wider range of uses and various geographic areas.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Infarto do Miocárdio , Intervenção Coronária Percutânea , Humanos , Resultado do Tratamento , Stents Farmacológicos/efeitos adversos , Doença da Artéria Coronariana/cirurgia , Doença da Artéria Coronariana/complicações , Infarto do Miocárdio/etiologia , Stents/efeitos adversos , Sistema de Registros , Intervenção Coronária Percutânea/efeitos adversos , Fatores de Risco , Ensaios Clínicos Controlados Aleatórios como Assunto
7.
Catheter Cardiovasc Interv ; 102(1): 36-45, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37172214

RESUMO

BACKGROUND: The combination of coronary imaging assessment and blood flow perturbation estimation has the potential to improve percutaneous coronary intervention (PCI) guidance. OBJECTIVES: We aimed to evaluate a novel method for fast computation of Murray law-based quantitative flow ratio (µQFR) from coregistered optical coherence tomography (OCT) and angiography (OCT-modulated µQFR, OCT-µQFR) in predicting physiological efficacy of PCI. METHODS: Patients treated by OCT-guided PCI in the OCT-arm of the Fractional Flow Reserve versus Optical Coherence Tomography to Guide RevasculariZAtion of Intermediate Coronary Stenoses trial (FORZA, NCT01824030) were included. Based on angiography and OCT before PCI, simulated residual OCT-µQFR was computed by assuming full stent expansion to the intended-to-treat segment. Plaque composition was automatically characterized using a validated artificial intelligence algorithm. Actual post-PCI OCT-µQFR pullback was computed based on coregistration of angiography and OCT acquired immediately after PCI. Suboptimal functional stenting result was defined as OCT-µQFR ≤ 0.90. RESULTS: Paired simulated residual OCT-µQFR and actual post-PCI OCT-µQFR were obtained in 76 vessels from 74 patients. Simulated residual OCT-µQFR showed good correlation (r = 0.80, p < 0.001), agreement (mean difference = -0.02 ± 0.02, p < 0.001), and diagnostic concordance (79%, 95% confidence interval: 70%-88%) with actual post-PCI OCT-µQFR. Actual post-PCI in-stent OCT-µQFR had a median value of 0.02 and was associated with left anterior descending artery lesion location (ß = 0.38, p < 0.001), higher baseline total plaque burden (ß = 0.25, p = 0.031), and fibrous plaque volume (ß = 0.24, p = 0.026). CONCLUSIONS: This study based on patients enrolled in a prospective OCT-guidance PCI trial shows that simulated residual OCT-µQFR had good correlation, agreement, and diagnostic concordance with actual post-PCI OCT-µQFR. In OCT-guided procedures, OCT-µQFR in-stent pressure drop was low and was significantly predicted by pre-PCI vessel/plaque characteristics.


Assuntos
Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Intervenção Coronária Percutânea , Humanos , Inteligência Artificial , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Vasos Coronários , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Valor Preditivo dos Testes , Estudos Prospectivos , Tomografia de Coerência Óptica/métodos , Resultado do Tratamento
8.
Catheter Cardiovasc Interv ; 101(6): 1036-1044, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-37017418

RESUMO

BACKGROUND: Isolate features of the coronary anatomy have been associated with the pathophysiology of atherosclerotic disease. Computational methods have been described to allow precise quantification of the complex three-dimensional (3D) coronary geometry. The present study tested whether quantitative parameters that describe the spatial 3D coronary geometry is associated with the extension and composition of the underlying coronary artery disease (CAD). METHODS: Patients with CAD scheduled for percutaneous intervention were investigated with coronary computed tomography angiography (CCTA), and invasive coronary angiography, and virtual histology intravascular ultrasound (IVUS-VH). For all target vessels, 3D centerlines were extracted from CCTA images and processed to quantify 23 geometric indexes, grouped into 3 main categories as follows: (i) length-based; (ii) curvature-based, torsion-based, and curvature/torsion-combined; (iii) vessel path-based. The geometric variables were compared with IVUS-VH parameters assessing the extent and composition of coronary atherosclerosis. RESULTS: A total of 36 coronary patients (99 vessels) comprised the study population. From the 23 geometric indexes, 18 parameters were significantly (p < 0.05) associated with at least 1 IVUS-VH parameter at a univariate analysis. All three main geometric categories provided parameters significantly related with atherosclerosis variables. The 3D geometric indexes were associated with the degree of atherosclerotic extension, as well as with plaque composition. Geometric features remained significantly associated with all IVUS-VH parameters even after multivariate adjustment for clinical characteristics. CONCLUSIONS: Quantitative 3D vessel morphology emerges as a relevant factor associated with atherosclerosis in patients with established CAD.


Assuntos
Aterosclerose , Doença da Artéria Coronariana , Placa Aterosclerótica , Humanos , Ultrassonografia de Intervenção/métodos , Resultado do Tratamento , Doença da Artéria Coronariana/patologia , Angiografia Coronária/métodos , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Valor Preditivo dos Testes
9.
Sensors (Basel) ; 23(7)2023 Mar 24.
Artigo em Inglês | MEDLINE | ID: mdl-37050471

RESUMO

Cardiac wireless implantable medical devices (CWIMD) have brought a paradigm shift in monitoring and treating various cardiac conditions, including heart failure, arrhythmias, and hypertension. One of the key elements in CWIMD is the implant antenna which uses radio frequency (RF) technology to wirelessly communicate and transmit data to external devices. However, wireless communication with a deeply implanted antenna using RF can be challenging due to the significant loss of electromagnetic (EM) signal at the air-skin interface, and second, due to the propagation and reflection of EM waves from different tissue boundaries. The air-skin interface loss of the EM wave is pronounced due to the absence of a matching medium. This paper investigates the EM propagation losses in the human body and presents a choice of optimal frequency for the design of the cardiac implant antenna and the dielectric properties of the matching medium. First, the dielectric properties of all tissues present in the human thorax including skin, fat, muscle, cartilage, and heart are analyzed as a function of frequency to study the EM wave absorption at different frequencies. Second, the penetration of EM waves inside the biological tissues is analyzed as a function of frequency. Third, a transmission line (TL) formalism approach is adopted to examine the optimal frequency band for designing a cardiac implant antenna and the matching medium for the air-skin interface. Finally, experimental validation is performed at two ISM frequencies, 433 MHz and 915 MHz, selected from the optimal frequency band (0.4-1.5 GHz) suggested by our analytical investigation. For experimental validation, two off-the-shelf flexible dipole antennas operating at selected ISM frequencies were used. The numerical and experimental findings suggested that for the specific application of a cardiac implant with a penetration depth of 7-17 cm, the most effective frequency range for operation is within 0.4-1.5 GHz. The findings based on the dielectric properties of thorax tissues, the penetration depth of EM waves, and the optimal frequency band have provided valuable information on developing and optimizing CWIMDs for cardiac care applications.


Assuntos
Coração , Próteses e Implantes , Humanos , Estudos de Viabilidade , Arritmias Cardíacas , Ondas de Rádio , Tecnologia sem Fio
10.
Lancet ; 398(10317): 2149-2159, 2021 12 11.
Artigo em Inglês | MEDLINE | ID: mdl-34742368

RESUMO

BACKGROUND: Compared with visual angiographic assessment, pressure wire-based physiological measurement more accurately identifies flow-limiting lesions in patients with coronary artery disease. Nonetheless, angiography remains the most widely used method to guide percutaneous coronary intervention (PCI). In FAVOR III China, we aimed to establish whether clinical outcomes might be improved by lesion selection for PCI using the quantitative flow ratio (QFR), a novel angiography-based approach to estimate the fractional flow reserve. METHODS: FAVOR III China is a multicentre, blinded, randomised, sham-controlled trial done at 26 hospitals in China. Patients aged 18 years or older, with stable or unstable angina pectoris or patients who had a myocardial infarction at least 72 h before screening, who had at least one lesion with a diameter stenosis of 50-90% in a coronary artery with a reference vessel of at least 2·5 mm diameter by visual assessment were eligible. Patients were randomly assigned to a QFR-guided strategy (PCI performed only if QFR ≤0·80) or an angiography-guided strategy (PCI based on standard visual angiographic assessment). Participants and clinical assessors were masked to treatment allocation. The primary endpoint was the 1-year rate of major adverse cardiac events, a composite of death from any cause, myocardial infarction, or ischaemia-driven revascularisation. The primary analysis was done in the intention-to-treat population. The trial was registered with ClinicalTrials.gov (NCT03656848). FINDINGS: Between Dec 25, 2018, and Jan 19, 2020, 3847 patients were enrolled. After exclusion of 22 patients who elected not to undergo PCI or who were withdrawn by their physicians, 3825 participants were included in the intention-to-treat population (1913 in the QFR-guided group and 1912 in the angiography-guided group). The mean age was 62·7 years (SD 10·1), 2699 (70·6%) were men and 1126 (29·4%) were women, 1295 (33·9%) had diabetes, and 2428 (63·5%) presented with an acute coronary syndrome. The 1-year primary endpoint occurred in 110 (Kaplan-Meier estimated rate 5·8%) participants in the QFR-guided group and in 167 (8·8%) participants in the angiography-guided group (difference, -3·0% [95% CI -4·7 to -1·4]; hazard ratio 0·65 [95% CI 0·51 to 0·83]; p=0·0004), driven by fewer myocardial infarctions and ischaemia-driven revascularisations in the QFR-guided group than in the angiography-guided group. INTERPRETATION: In FAVOR III China, among patients undergoing PCI, a QFR-guided strategy of lesion selection improved 1-year clinical outcomes compared with standard angiography guidance. FUNDING: Beijing Municipal Science and Technology Commission, Chinese Academy of Medical Sciences, and the National Clinical Research Centre for Cardiovascular Diseases, Fuwai Hospital.


Assuntos
Angiografia Coronária , Doença da Artéria Coronariana/cirurgia , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Intervenção Coronária Percutânea , China , Vasos Coronários/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
11.
Am Heart J ; 246: 32-43, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34990582

RESUMO

BACKGROUND: Current ESC guidelines recommend the use of intra-coronary pressure guidewires for functional assessment of intermediate-grade coronary stenoses. Angiography-derived quantitative flow ratio (QFR) is a novel method of assessing these stenoses, and guiding percutaneous coronary intervention (PCI). METHODS/DESIGN: The PIONEER IV trial is a prospective, all-comers, multi-center trial, which will randomize 2,540 patients in a 1:1 ratio to PCI guided by angiography-derived physiology or usual care, with unrestricted use in both arms of the Healing-Targeted Supreme sirolimus-eluting stent (HT Supreme). The stent's fast, biologically healthy, and robust endothelial coverage allows for short dual-antiplatelet therapy (DAPT); hence the antiplatelet regimen of choice is 1-month DAPT, followed by ticagrelor monotherapy. In the angiography-derived physiology guided arm, lesions will be functionally assessed using on-line QFR, with stenting indicated in lesions with a QFR ≤0.80. Post-stenting, QFR will be repeated in the stented vessel(s), with post-dilatation or additional stenting recommended if the QFR<0.91 distal to the stent, or if the delta QFR (across the stent) is >0.05. Usual care PCI is performed according to standard clinical practice. The primary endpoint is a non-inferiority comparison of the patient-oriented composite endpoint (POCE) of all-cause death, any stroke, any myocardial infarction, or any clinically, and physiologically driven revascularization with a non-inferiority risk-difference margin of 3.2%, at 1-year post-procedure. Clinical follow-up will be up to 3 years. SUMMARY: The PIONEER IV trial aims to demonstrate non-inferiority of QFR-guided PCI to usual care PCI with respect to POCE at 1-year in patients treated with HT Supreme stents and ticagrelor monotherapy. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov UNIQUE IDENTIFIER: NCT04923191 CLASSIFICATIONS: Interventional Cardiology.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Intervenção Coronária Percutânea , Angiografia Coronária , Doença da Artéria Coronariana/terapia , Humanos , Intervenção Coronária Percutânea/métodos , Estudos Prospectivos , Stents , Ticagrelor/uso terapêutico , Resultado do Tratamento
12.
BMC Cancer ; 22(1): 396, 2022 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-35413811

RESUMO

Cancer-therapy related cardiotoxicity (CTRCT) is a significant and frequent complication of monoclonal antibody directed therapy, especially Trastuzumab, for human epidermal growth factor receptor 2 (HER2) overexpressing breast cancers. Reliable, clinically available molecular predictive markers of CTRCT have not yet been developed. Identifying specific genetic variants and their molecular markers, which make the host susceptible to this complication is key to personalised risk stratification. A systematic review was conducted until April 2021, using the Medline, Embase databases and Google Scholar, to identify studies genetic and RNA-related markers associated with CTRCT in HER2 positive breast cancer patients. So far, researchers have mainly focused on HER2 related polymorphisms, revealing codons 655 and 1170 variants as the most likely SNPs associated with cardiotoxicity, despite some contradictory results. More recently, new potential genetic markers unrelated to the HER2 gene, and linked to known cardiomyopathy genes or to genes regulating cardiomyocytes apoptosis and metabolism, have been detected. Moreover, microRNAs are gaining increasing recognition as additional potential molecular markers in the cardio-oncology field, supported by encouraging preliminary data about their relationship with cardiotoxicity in breast cancers. In this review, we sought to synthesize evidence for genetic variants and RNA-related molecular markers associated with cardiotoxicity in HER2-positive breast cancer.


Assuntos
Neoplasias da Mama , Cardiotoxicidade , Neoplasias da Mama/complicações , Neoplasias da Mama/tratamento farmacológico , Neoplasias da Mama/genética , Cardiotoxicidade/genética , Feminino , Humanos , RNA , Receptor ErbB-2/genética , Receptor ErbB-2/metabolismo , Trastuzumab/efeitos adversos
13.
Catheter Cardiovasc Interv ; 99(2): 424-432, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-33565719

RESUMO

OBJECTIVE: Present bench study aimed to evaluate whether technical characteristics of Fantom Encore® bioresorbable scaffold (BRS) allow to perform proximal optimization/side branch dilation/proximal optimization (POT-SB-POT) technique, as an adequate solution for bifurcation percutaneous coronary intervention. METHODS: Two Fantom Encore® BRS platforms (small with 3.0 mm nominal diameter, n = 7; and large with 3.5 mm nominal diameter, n = 7) were evaluated in bench models, which were designed according to Finet-law and fitted to nominal scaffold diameter in the distal main branch (MB) and fitted to indicated maximal expansion capacity in the proximal main branch (MB). Results were evaluated by (a) fluoroscopy, (b) optical coherence tomography (OCT) and (c) micro-computed tomography (µCT). RESULTS: All procedures were performed according to the protocol. Careful review of the fluoroscopic loops by an independent operator did not reveal any strut fracture or major deformation. By OCT the overall rate of perfectly apposed struts in the bifurcation area was 15 ± 6% after SB opening, that increased significantly but remained low with 22 ± 9% after final POT (p = .001). Compared to SB ballooning alone, significant benefit of final POT was found in rate of perfect apposition in the proximal MB (15 ± 12% vs. 26 ± 15%, respectively; p = .017) and at the abostial side of polygon of confluence (7 ± 9% vs. 16 ± 13%, respectively; p = .005). µCT analysis revealed a single strut fracture in one case with the small platform, while four cases showed single or multiple strut fractures with the large platform. CONCLUSION: The mechanical characteristics of the device are not suitable for use of Conventional techniques for bifurcation PCI such as POT-SB-POT. The use of Fantom Encore® BRS for bifurcation PCI with relevant SB should not be encouraged.


Assuntos
Angioplastia Coronária com Balão , Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Vasos Coronários/diagnóstico por imagem , Humanos , Modelos Cardiovasculares , Intervenção Coronária Percutânea/efeitos adversos , Desenho de Prótese , Tomografia de Coerência Óptica , Resultado do Tratamento , Microtomografia por Raio-X
14.
Catheter Cardiovasc Interv ; 99(2): 357-365, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-33502809

RESUMO

BACKGROUND: Current guidelines recommend dual antiplatelet therapy (DAPT) following percutaneous coronary intervention for 6-12 months in patients with acute coronary syndrome (ACS) and 3-6 months in those with chronic coronary syndromes (CCS). Whether DAPT duration has a differential effect on outcomes following treatment of ischemic coronary disease with durable versus biodegradable drug-eluting stent (DES) is poorly defined. METHODS: The TARGET All Comer study was a randomized trial of patients with ischemic coronary artery disease assigned to treatment with either a biodegradable polymer DES (Firehawk) or a durable polymer DES (XIENCE). This pre-specified TARGET AC sub-analysis sought to evaluate the 2-year clinical outcomes before and after DAPT discontinuation. The primary endpoint was target lesion failure (TLF). RESULTS: A total of 1,296 (78.4%) of 1,653 randomized patients were included in this substudy, of which 1,210 (93.4%) remained on DAPT at 6 months, 863 (66.6%) at 12 months, and 409 (31.6%) at 2 years. There was no difference in TLF between patients treated with Firehawk and XIENCE stents from index procedure to DAPT discontinuation (8.0 and 7.7%, p > .99) or after DAPT discontinuation (2.9 vs. 3.8%, p = .16). After DAPT discontinuation, target vessel myocardial infarction (1.3 vs. 3.3%, p = .07), and ischemia-driven target lesion revascularization (0.5 vs. 1.9%, p = .06) favored treatment with Firehawk. CONCLUSIONS: Although TLF was comparable for both Firehawk and XIENCE stent groups before and after DAPT discontinuation, after DAPT discontinuation, there was a trend for less target vessel myocardial infarction and ischemia-driven revascularization with the biodegradable polymer DES.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Intervenção Coronária Percutânea , Implantes Absorvíveis , Doença da Artéria Coronariana/tratamento farmacológico , Doença da Artéria Coronariana/terapia , Everolimo/efeitos adversos , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Inibidores da Agregação Plaquetária/efeitos adversos , Polímeros , Sirolimo/efeitos adversos , Resultado do Tratamento
15.
Catheter Cardiovasc Interv ; 99(3): 746-753, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34468076

RESUMO

OBJECTIVES: To validate QFR using 4-F diagnostic catheters compared to using 6-F guiding catheters, with conventional guidewire-based FFR as the reference standard, using independent core laboratory analysis. BACKGROUND: Quantitative Flow Ratio (QFR) allows Fractional Flow Reserve (FFR) calculation based on the coronary angiogram, using 5- or 6-French (F) catheters. However, the use of 4-F diagnostic catheters to perform coronary angiography is currently routine in some centers. METHODS: We included all consecutive patients with stable coronary artery disease and indicated for physiological assessment. QFR was performed using a 4-F diagnostic catheter, then QFR was performed using a 6-F guiding catheter while conventional FFR was measured using a pressure guidewire. Angiograms were sent to two separate core laboratories. RESULTS: One hundred lesions in 67 consecutive patients with QFR performed using 4-F and 6-F catheters, and with conventional FFR, were included. Pearson's correlation coefficient was for QFR 4-F vs. FFR 0.91 [0.87-0.94], for QFR 6-F vs. FFR 0.90 [0.86-0.94], and for QFR 4-F vs. QFR 6-F 0.93 [0.90-0.95]. Receiver-operator characteristic curves (ROC) comparing the ability to predict an FFR value above or below 0.80 with QFR 4-F and 6-F were generated. The area under the ROC curve (AUC) vs. FFR was 0.972 [0.95-0.99] for QFR 4-F and 0.970 [0.94-0.99] for QFR 6-F. CONCLUSIONS: Our study demonstrated the feasibility of performing QFR analysis from angiograms obtained by 4-F catheters, and showed a good correlation with QFR performed using 6-F catheters as well as with conventional FFR performed using a pressure guidewire.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Catéteres , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/terapia , Vasos Coronários , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Humanos , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Índice de Gravidade de Doença , Resultado do Tratamento
16.
Artigo em Inglês | MEDLINE | ID: mdl-36519717

RESUMO

OBJECTIVES: The objective of the present study was to compare plaque burden (PB) calculated from optical coherence tomography (OCT) using deep learning (DL) with PB derived from co-registered intravascular ultrasound (IVUS). BACKGROUND: A DL algorithm was developed for automated plaque characterization and PB quantification from OCT images. However, the performance of this algorithm for PB quantification has not been validated. METHODS: Five-year follow-up OCT and IVUS images from 15 patients implanted with bioresorbable vascular scaffold (BVS) at baseline were analyzed. Precise co-registration for 72 anatomical slices was achieved utilizing unique BVS radiopaque markers. PB derived from OCT DL and IVUS were compared. OCT cross-sections were divided into four subgroups with different media visibility level. The impact of media visibility on the numerical difference between OCT-derived and IVUS-derived PB was investigated. The stent sizes selected by OCT DL and IVUS were compared. RESULTS: Sixty-four paired OCT and IVUS cross-sections were compared. OCT DL showed good concordance with IVUS for PB assessment (ICC = 0.81, difference = -3.53 ± 6.17%, p < 0.001). The numerical difference between OCT DL-derived PB and IVUS-derived PB was not substantially impacted by missing segments of media visualization (p = 0.21). OCT DL showed a diagnostic accuracy of 92% in identifying PB > 65%. The stent sizes selected by OCT DL were smaller compared to the ones selected by IVUS (difference = 0.30 ± 0.34 mm, p < 0.001). CONCLUSIONS: The DL algorithm provides a feasible and reliable method for automated PB estimation from OCT, irrespective of media visibility. OCT DL showed good diagnostic accuracy in identifying PB > 65%, revealing its potential to complement conventional OCT imaging.

17.
Eur Heart J ; 42(27): 2695-2707, 2021 07 15.
Artigo em Inglês | MEDLINE | ID: mdl-33822922

RESUMO

Percutaneous coronary intervention (PCI) guided by coronary physiology provides symptomatic benefit and improves patient outcomes. Nevertheless, over one-fourth of patients still experience recurrent angina or major adverse cardiac events following the index procedure. Coronary angiography, the current workhorse for evaluating PCI efficacy, has limited ability to identify suboptimal PCI results. Accumulating evidence supports the usefulness of immediate post-procedural functional assessment. This review discusses the incidence and possible mechanisms behind a suboptimal physiology immediately after PCI. Furthermore, we summarize the current evidence base supporting the usefulness of immediate post-PCI functional assessment for evaluating PCI effectiveness, guiding PCI optimization, and predicting clinical outcomes. Multiple observational studies and post hoc analyses of datasets from randomized trials demonstrated that higher post-PCI functional results are associated with better clinical outcomes as well as a reduced rate of residual angina and repeat revascularization. As such, post-PCI functional assessment is anticipated to impact patient management, secondary prevention, and resource utilization. Pre-PCI physiological guidance has been shown to improve clinical outcomes and reduce health care costs. Whether similar benefits can be achieved using post-PCI physiological assessment requires evaluation in randomized clinical outcome trials.


Assuntos
Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Intervenção Coronária Percutânea , Angina Pectoris , Angiografia Coronária , Doença da Artéria Coronariana/cirurgia , Custos de Cuidados de Saúde , Humanos , Resultado do Tratamento
18.
Eur Heart J ; 42(45): 4638-4651, 2021 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-34002203

RESUMO

AIMS: The value of elective coronary revascularisation plus medical therapy over medical therapy alone in managing stable patients with coronary artery disease is debated. We reviewed all trials comparing the two strategies in this population. METHODS AND RESULTS: From inception through November 2020, MEDLINE, EMBASE, Google Scholar, and other databases were searched for randomised trials comparing revascularisation against medical therapy alone in clinically stable coronary artery disease patients. Treatment effects were measured by rate ratios (RRs) with 95% confidence intervals, using random-effects models. Cardiac mortality was the pre-specified primary endpoint. Spontaneous myocardial infarction (MI) and its association with cardiac mortality were secondary endpoints. Further endpoints included all-cause mortality, any MI, and stroke. Longest follow-up data were abstracted. The study is registered with PROSPERO (CRD42021225598). Twenty-five trials involving 19 806 patients (10 023 randomised to revascularisation plus medical therapy and 9783 to medical therapy alone) were included. Compared with medical therapy alone, revascularisation yielded a lower risk of cardiac death [RR 0.79 (0.67-0.93), P < 0.01] and spontaneous MI [RR 0.74 (0.64-0.86), P < 0.01]. By meta-regression, the cardiac death risk reduction after revascularisation, compared with medical therapy alone, was linearly associated with follow-up duration [RR per 4-year follow-up: 0.81 (0.69-0.96), P = 0.008], spontaneous MI absolute difference (P = 0.01) and percentage of multivessel disease at baseline (P = 0.004). Trial sequential and sensitivity analyses confirmed the reliability of the cardiac mortality findings. All-cause mortality [0.94 (0.87-1.01), P = 0.11], any MI (P = 0.14), and stroke risk (P = 0.30) did not differ significantly between strategies. CONCLUSION: In stable coronary artery disease patients, randomisation to elective coronary revascularisation plus medical therapy led to reduced cardiac mortality compared with medical therapy alone. The cardiac survival benefit after revascularisation improved with longer follow-up times and was associated with fewer spontaneous MIs.


Assuntos
Doença da Artéria Coronariana , Infarto do Miocárdio , Causas de Morte , Doença da Artéria Coronariana/terapia , Humanos , Infarto do Miocárdio/terapia , Revascularização Miocárdica , Ensaios Clínicos Controlados Aleatórios como Assunto , Reprodutibilidade dos Testes
19.
Sensors (Basel) ; 22(21)2022 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-36366097

RESUMO

The wireless monitoring of key physiological parameters such as heart rate, respiratory rate, temperature, and pressure can aid in preventive healthcare, early diagnosis, and patient-tailored treatment. In wireless implantable sensors, the distance between the sensor and the reader device is prone to be influenced by the operating frequency, as well as by the medium between the sensor and the reader. This manuscript presents an ex vivo investigation of the wireless linkage between an implantable sensor and an external reader for medical applications. The sensor was designed and fabricated using a cost-effective and accessible fabrication process. The sensor is composed of a circular planar inductor (L) and a circular planar capacitor (C) to form an inductor-capacitor (LC) resonance tank circuit. The reader system comprises a readout coil and data acquisition instrumentation. To investigate the effect of biological medium on wireless linkage, the readout distance between the sensor and the readout coil was examined independently for porcine and ovine tissues. In the bench model, to mimic the bio-environment for the investigation, skin, muscle, and fat tissues were used. The relative magnitude of the reflection coefficient (S11) at the readout coil was used as a metric to benchmark wireless linkage. A readable linkage signal was observed on the readout coil when the sensor was held up to 2.5 cm under layers of skin, muscle, and fat tissue. To increase the remote readout distance of the LC sensor, the effect of the repeater coil was also investigated. The experimental results showed that the magnitude of the reflection coefficient signal was increased 3-3.5 times in the presence of the repeater coil, thereby increasing the signal-to-noise ratio of the detected signal. Therefore, the repeater coil between the sensor and the readout coil allows a larger sensing range for a variety of applications in implanted or sealed fields.


Assuntos
Próteses e Implantes , Tecnologia sem Fio , Animais , Ovinos , Suínos , Vibração
20.
Sensors (Basel) ; 22(21)2022 Oct 24.
Artigo em Inglês | MEDLINE | ID: mdl-36365837

RESUMO

With the recent advancements in the field of wearable technologies, the opportunity to monitor stress continuously using different physiological variables has gained significant interest. The early detection of stress can help improve healthcare and minimizes the negative impact of long-term stress. This paper reports outcomes of a pilot study and associated stress-monitoring dataset, named the "Stress-Predict Dataset", created by collecting physiological signals from healthy subjects using wrist-worn watches with a photoplethysmogram (PPG) sensor. While wearing these watches, 35 healthy volunteers underwent a series of tasks (i.e., Stroop color test, Trier Social Stress Test and Hyperventilation Provocation Test), along with a rest period in-between each task. They also answered questionnaires designed to induce stress levels compatible with daily life. The changes in the blood volume pulse (BVP) and heart rate were recorded by the watch and were labelled as occurring during stress-inducing tasks or a rest period (no stress). Additionally, respiratory rate was estimated using the BVP signal. Statistical models and personalised adaptive reference ranges were used to determine the utility of the proposed stressors and the extracted variables (heart rate and respiratory rate). The analysis showed that the interview session was the most significant stress stimulus, causing a significant variation in heart rate of 27 (77%) participants and respiratory rate of 28 (80%) participants out of 35. The outcomes of this study contribute to the understanding the role of stressors and their association with physiological response and provide a dataset to help develop new wearable solutions for more reliable, valid, and sensitive physio-logical stress monitoring.


Assuntos
Dispositivos Eletrônicos Vestíveis , Humanos , Projetos Piloto , Frequência Cardíaca/fisiologia , Monitorização Fisiológica , Taxa Respiratória , Fotopletismografia
SELEÇÃO DE REFERÊNCIAS