Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 47
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Am J Epidemiol ; 2024 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-38879739

RESUMO

This study examined how race/ethnicity, sex/gender, and sexual orientation intersect under interlocking systems of oppression to socially pattern depression among US adults. With cross-sectional data from the 2015-2020 National Survey on Drug Use and Health (NSDUH; n=234,722), we conducted design-weighted multilevel analysis of individual heterogeneity and discriminatory accuracy (MAIHDA) under an intersectional framework to predict past-year and lifetime major depressive episode (MDE). With 42 intersectional groups constructed from seven race/ethnicity, two sex/gender, and three sexual orientation categories, we estimated age-standardized prevalence and excess/reduced prevalence attributable to two-way or higher interaction effects. Models revealed heterogeneity across groups, with prevalence ranging from 1.9-19.7% (past-year) and 4.5-36.5% (lifetime). Approximately 12.7% (past-year) and 12.5% (lifetime) of total individual variance were attributable to between-group differences, indicating key relevance of intersectional groups in describing the population distribution of depression. Main effects indicated, on average, people who were White, women, gay/lesbian, or bisexual had greater odds of MDE. Main effects explained most between-group variance. Interaction effects (past-year: 10.1%; lifetime: 16.5%) indicated a further source of heterogeneity around averages with groups experiencing excess/reduced prevalence compared to main effects expectations. We extend the MAIHDA framework to calculate nationally representative estimates from complex sample survey data using design-weighted, Bayesian methods.

2.
Ann Bot ; 131(4): 555-568, 2023 04 28.
Artigo em Inglês | MEDLINE | ID: mdl-36794962

RESUMO

BACKGROUND: Relative growth rate (RGR) has a long history of use in biology. In its logged form, RGR = ln[(M + ΔM)/M], where M is size of the organism at the commencement of the study, and ΔM is new growth over time interval Δt. It illustrates the general problem of comparing non-independent (confounded) variables, e.g. (X + Y) vs. X. Thus, RGR depends on what starting M(X) is used even within the same growth phase. Equally, RGR lacks independence from its derived components, net assimilation rate (NAR) and leaf mass ratio (LMR), as RGR = NAR × LMR, so that they cannot legitimately be compared by standard regression or correlation analysis. FINDINGS: The mathematical properties of RGR exemplify the general problem of 'spurious' correlations that compare expressions derived from various combinations of the same component terms X and Y. This is particularly acute when X >> Y, the variance of X or Y is large, or there is little range overlap of X and Y values among datasets being compared. Relationships (direction, curvilinearity) between such confounded variables are essentially predetermined and so should not be reported as if they are a finding of the study. Standardizing by M rather than time does not solve the problem. We propose the inherent growth rate (IGR), lnΔM/lnM, as a simple, robust alternative to RGR that is independent of M within the same growth phase. CONCLUSIONS: Although the preferred alternative is to avoid the practice altogether, we discuss cases where comparing expressions with components in common may still have utility. These may provide insights if (1) the regression slope between pairs yields a new variable of biological interest, (2) the statistical significance of the relationship remains supported using suitable methods, such as our specially devised randomization test, or (3) multiple datasets are compared and found to be statistically different. Distinguishing true biological relationships from spurious ones, which arise from comparing non-independent expressions, is essential when dealing with derived variables associated with plant growth analyses.


Assuntos
Desenvolvimento Vegetal , Folhas de Planta
3.
Pediatr Cardiol ; 42(3): 716-720, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33416921

RESUMO

We sought to assess the effect of a shorter medication treatment course (up to 4-6 months of age) on the recurrence of infantile supraventricular tachycardia (SVT). This was a retrospective review of infants with SVT diagnosed at age 0-12 months at Rady Children's Hospital (2010-2017). Infants with structural congenital heart disease, automatic tachycardias, atrial flutter, or lack of follow-up data were excluded. Seventy-four infants met criteria. Median age at diagnosis was 6 days (IQR 0-21 days); 28.4% presented with fetal tachycardia. Median gestational age was 38.4 weeks (IQR 36-40), 30% were preterm. Median age at medication discontinuation was 6.7 months (IQR 4.6-9.8). Therapy was stopped at younger age in patients managed by pediatric electrophysiologist (vs. general pediatric cardiologist): 4.9 vs. 8.6 months (p = 0.03). Thirty-eight patients (51.4%) were treated for < 6 months; 32.4% for 6-12 months, and 16.2% for > 12 months. SVT recurrence was similar for these groups: 13.2% vs. 16.7%, and 33.3%, respectively, (p = 0.27). Most patients with recurrence required emergency care, though none had significant adverse outcomes. Infants with SVT and structurally normal cardiac anatomy, who remain recurrence free on a single agent, have no increased risk of recurrence with shorter treatment courses of 4-6 months, compared to traditional treatment duration of 6-12 months.


Assuntos
Antiarrítmicos/uso terapêutico , Taquicardia Supraventricular/tratamento farmacológico , Criança , Pré-Escolar , Duração da Terapia , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Recidiva , Estudos Retrospectivos , Taquicardia Supraventricular/diagnóstico
4.
J Neuroeng Rehabil ; 18(1): 50, 2021 03 18.
Artigo em Inglês | MEDLINE | ID: mdl-33736656

RESUMO

BACKGROUND: Current commercial prosthetic hand controllers limit patients' ability to fully engage high Degree-of-Freedom (DoF) prosthetic hands. Available feedforward controllers rely on large training data sets for controller setup and a need for recalibration upon prosthesis donning. Recently, an intuitive, proportional, simultaneous, regression-based 3-DoF controller remained stable for several months without retraining by combining chronically implanted electromyography (ciEMG) electrodes with a K-Nearest-Neighbor (KNN) mapping technique. The training dataset requirements for simultaneous KNN controllers increase exponentially with DoF, limiting the realistic development of KNN controllers in more than three DoF. We hypothesize that a controller combining linear interpolation, the muscle synergy framework, and a sufficient number of ciEMG channels (at least two per DoF), can allow stable, high-DoF control. METHODS: Two trans-radial amputee subjects, S6 and S8, were implanted with percutaneously interfaced bipolar intramuscular electrodes. At the time of the study, S6 and S8 had 6 and 8 bipolar EMG electrodes, respectively. A Virtual Reality (VR) system guided users through single and paired training movements in one 3-DoF and four different 4-DoF cases. A linear model of user activity was built by partitioning EMG feature space into regions bounded by vectors of steady state movement EMG patterns. The controller evaluated online EMG signals by linearly interpolating the movement class labels for surrounding trained EMG movements. This yields a simultaneous, continuous, intuitive, and proportional controller. Controllers were evaluated in 3-DoF and 4-DoF through a target-matching task in which subjects controlled a virtual hand to match 80 targets spanning the available movement space. Match Percentage, Time-To-Target, and Path Efficiency were evaluated over a 10-month period based on subject availability. RESULTS AND CONCLUSIONS: In 3-DoF, S6 and S8 matched most targets and demonstrated stable control after 8 and 10 months, respectively. In 4-DoF, both subjects initially found two of four 4-DoF controllers usable, matching most targets. S8 4-DoF controllers were stable, and showed improving trends over 7-9 months without retraining or at-home practice. S6 4-DoF controllers were unstable after 7 months without retraining. These results indicate that the performance of the controller proposed in this study may remain stable, or even improve, provided initial viability and a sufficient number of EMG channels. Overall, this study demonstrates a controller capable of stable, simultaneous, proportional, intuitive, and continuous control in 3-DoF for up to ten months and in 4-DoF for up to nine months without retraining or at-home use with minimal training times.


Assuntos
Amputados/reabilitação , Membros Artificiais , Eletrodos Implantados , Mãos , Movimento , Treinamento por Simulação/métodos , Realidade Virtual , Braço/inervação , Interfaces Cérebro-Computador , Eletromiografia/métodos , Humanos , Modelos Lineares , Masculino , Músculo Esquelético/inervação , Educação de Pacientes como Assunto/métodos , Modalidades de Fisioterapia/instrumentação , Software
5.
Eur Arch Psychiatry Clin Neurosci ; 269(4): 387-395, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29980921

RESUMO

The corpus callosum has become a key area of interest for researchers in severe mental illness. Disruptions in fractional anisotropy in the callosum have been reported in schizophrenia and major depressive disorder. No change has been reported in oligodendrocyte density and overall size of the callosum in either illness, suggesting that gross morphology is unchanged, but subtler organisational disruption may exist within this structure. Using high-resolution oil immersion microscopy, we examined the cross-sectional area of the nerve fibre and the axonal myelin sheath; and using standard high-resolution light microscopy, we measured the density of myelinated axons. These measurements were made in the splenium of the corpus callosum. Measures were taken in the sagittal plane in the callosal splenium to contrast with the previous similar examination of the callosal genu. Cases of major depressive disorder had significantly decreased mean myelin cross-sectional area (p = 0.014) per axon in the splenium than in controls or schizophrenia groups. There was no significant change in the density of myelinated axons. The results suggest a clear decrease of myelin in the axons of the callosal splenium in MDD, although this type of neuropathological study is unable to clarify whether this is caused by changes during life or has a developmental origin. In contrast with increased myelin in the callosal genu, this result suggests a longitudinal change in callosal myelination in major depressive disorder not present in normal or schizophrenic brains.


Assuntos
Axônios/patologia , Corpo Caloso/patologia , Transtorno Depressivo Maior/patologia , Bainha de Mielina/patologia , Bancos de Tecidos , Adulto , Corpo Caloso/diagnóstico por imagem , Transtorno Depressivo Maior/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
6.
Pediatr Crit Care Med ; 20(11): 1007-1020, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31246743

RESUMO

OBJECTIVES: Genetic disorders are a leading contributor to mortality in the neonatal ICU and PICU in the United States. Although individually rare, there are over 6,200 single-gene diseases, which may preclude a genetic diagnosis prior to ICU admission. Rapid whole genome sequencing is an emerging method of diagnosing genetic conditions in time to affect ICU management of neonates; however, its clinical utility has yet to be adequately demonstrated in critically ill children. This study evaluates next-generation sequencing in pediatric critical care. DESIGN: Retrospective cohort study. SETTING: Single-center PICU in a tertiary children's hospital. PATIENTS: Children 4 months to 18 years admitted to the PICU who were nominated between July 2016 and May 2018. INTERVENTIONS: Rapid whole genome sequencing with targeted phenotype-driven analysis was performed on patients and their parents, when parental samples were available. MEASUREMENTS AND MAIN RESULTS: A molecular diagnosis was made by rapid whole genome sequencing in 17 of 38 children (45%). In four of the 17 patients (24%), the genetic diagnoses led to a change in management while in the PICU, including genome-informed changes in pharmacotherapy and transition to palliative care. Nine of the 17 diagnosed children (53%) had no dysmorphic features or developmental delay. Eighty-two percent of diagnoses affected the clinical management of the patient and/or family after PICU discharge, including avoidance of biopsy, administration of factor replacement, and surveillance for disorder-related sequelae. CONCLUSIONS: This study demonstrates a retrospective evaluation for undiagnosed genetic disease in the PICU and clinical utility of rapid whole genome sequencing in a portion of critically ill children. Further studies are needed to identify PICU patients who will benefit from rapid whole genome sequencing early in PICU admission when the underlying etiology is unclear.


Assuntos
Doenças Genéticas Inatas/diagnóstico , Sequenciamento Completo do Genoma , Adolescente , Criança , Pré-Escolar , Estado Terminal/terapia , Feminino , Humanos , Lactente , Unidades de Terapia Intensiva Pediátrica/estatística & dados numéricos , Masculino , Medicina de Precisão/métodos , Estudos Retrospectivos
7.
J Neuroeng Rehabil ; 16(1): 147, 2019 11 21.
Artigo em Inglês | MEDLINE | ID: mdl-31752886

RESUMO

BACKGROUND: Modern prosthetic hands are typically controlled using skin surface electromyographic signals (EMG) from remaining muscles in the residual limb. However, surface electrode performance is limited by changes in skin impedance over time, day-to-day variations in electrode placement, and relative motion between the electrodes and underlying muscles during movement: these limitations require frequent retraining of controllers. In the presented study, we used chronically implanted intramuscular electrodes to minimize these effects and thus create a more robust prosthetic controller. METHODS: A study participant with a transradial amputation was chronically implanted with 8 intramuscular EMG electrodes. A K Nearest Neighbor (KNN) regression velocity controller was trained to predict intended joint movement direction using EMG data collected during a single training session. The resulting KNN was evaluated over 12 weeks and in multiple arm posture configurations, with the participant controlling a 3 Degree-of-Freedom (DOF) virtual reality (VR) hand to match target VR hand postures. The performance of this EMG-based controller was compared to a position-based controller that used movement measured from the participant's opposite (intact) hand. Surface EMG was also collected for signal quality comparisons. RESULTS: Signals from the implanted intramuscular electrodes exhibited less crosstalk between the various channels and had a higher Signal-to-Noise Ratio than surface electrode signals. The performance of the intramuscular EMG-based KNN controller in the VR control task showed no degradation over time, and was stable over the 6 different arm postures. Both the EMG-based KNN controller and the intact hand-based controller had 100% hand posture matching success rates, but the intact hand-based controller was slightly superior in regards to speed (trial time used) and directness of the VR hand control (path efficiency). CONCLUSIONS: Chronically implanted intramuscular electrodes provide negligible crosstalk, high SNR, and substantial VR control performance, including the ability to use a fixed controller over 12 weeks and under different arm positions. This approach can thus be a highly effective platform for advanced, multi-DOF prosthetic control.


Assuntos
Membros Artificiais , Eletrodos Implantados , Músculo Esquelético/fisiologia , Desenho de Prótese , Interface Usuário-Computador , Adulto , Amputação Cirúrgica , Eletromiografia/métodos , Mãos/fisiologia , Humanos , Masculino , Movimento/fisiologia
8.
Rheumatology (Oxford) ; 57(suppl_5): v9-v17, 2018 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-30137589

RESUMO

Objective: To survey an international sample of providers to determine their current practices for the prevention, screening, and treatment of congenital heart block (CHB) due to maternal Ro/SSA antibodies. Methods: A survey was designed by the organizing committee of the 9th International Conference of Reproduction, Pregnancy and Rheumatic Diseases. It was sent to attendants of the conference and authors of recent publications or abstracts at ACR 2012, 2013 or 2014 on rheumatic diseases and pregnancy. Results: In anti-Ro/SSA positive women, 80% of 49 respondents recommended screening by serial fetal echocardiogram (ECHO), with most starting at week 16 (59%) and stopping at week 28 (25%), although the time to stop varied widely. For women without a prior infant with neonatal lupus, respondents recommend every other week (44%) or weekly (28%) fetal ECHOs. For women with a prior infant with neonatal lupus, 80% recommend weekly fetal ECHOs. To prevent CHB, HCQ was recommended by 67% of respondents and most would start pre-pregnancy (62%). Respondents were asked about medications to treat varying degrees of CHB in a 20-week pregnant, anti-Ro and La positive SLE patient. For first degree, respondents recommended starting dexamethasone (53%) or HCQ (43%). For second degree, respondents recommended starting dexamethasone (88%). For third degree, respondents recommended starting dexamethasone (55%) or IVIg (33%), although 27% would not start treatment. Conclusion: Despite the absence of official guidelines, many physicians with a focus on pregnancy and rheumatic disease have developed similar patterns in the screening, prevention and treatment of CHB.


Assuntos
Ecocardiografia , Bloqueio Cardíaco/congênito , Lúpus Eritematoso Sistêmico/congênito , Padrões de Prática Médica/estatística & dados numéricos , Diagnóstico Pré-Natal , Anticorpos Antinucleares/análise , Ecocardiografia/métodos , Feminino , Bloqueio Cardíaco/diagnóstico por imagem , Bloqueio Cardíaco/prevenção & controle , Humanos , Lúpus Eritematoso Sistêmico/complicações , Lúpus Eritematoso Sistêmico/diagnóstico por imagem , Gravidez , Trimestres da Gravidez/imunologia , Diagnóstico Pré-Natal/métodos , Inquéritos e Questionários
9.
Pharmacol Res ; 121: 114-121, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28465217

RESUMO

Major Depressive Disorder (MDD, ICD-10: F-33) is a prevalent illness in which the pathogenic mechanism remains elusive. Recently an important role has been attributed to neuro-inflammation, and specifically the NLRP3-inflammasome complex, in the pathogenesis of MDD. This suggests a key role for immunomodulation as a key pathway in the treatment of this disorder. This study evaluates the involvement of nine common antidepressants in the NLRP3-inflammasome complex (fluoxetine, paroxetine, mianserin, mirtazapine, venlafaxine, desvenlafaxine, amitriptyline, imipramine and agomelatine), both in in vitro THP-1 cells stimulated by ATP, and in a stress-induced depressive animal or MDD patients. Antidepressant treatment induced inflammasome inhibition was observed by decreased serum levels of IL-1ß and IL-18 and decrease of NLRP3 and IL-1ß (p17) protein expression. This was also observed under stress-induced depressive behaviour and inflammasome activation in C57Bl/6 mice in vivo. Deletion of key autophagy mediator Atg5 in embryonic fibroblasts (MEF cells) showed an autophagy dependent-NLRP3-inflammasome inhibition by antidepressant treatment. These results suggest the NLRP3-inflammasome could be a biomarker for antidepressant treatment response in MDD patients, and therefore the monitoring of NLRP3 expression levels and/or IL-1ß/IL-18 release may have clinical value in drug selection. Existing evidence suggests an anti-inflammatory effect of some antidepressants shown by IL-1ß, IL-6 and TNF-α. Our data have shown that antidepressant-mediated autophagy may have a role in restoration of certain metabolic and immunological pathways in MDD patients.


Assuntos
Antidepressivos/uso terapêutico , Autofagia/efeitos dos fármacos , Transtorno Depressivo Maior/tratamento farmacológico , Inflamassomos/antagonistas & inibidores , Proteína 3 que Contém Domínio de Pirina da Família NLR/antagonistas & inibidores , Adulto , Animais , Antidepressivos/farmacologia , Linhagem Celular , Transtorno Depressivo Maior/sangue , Transtorno Depressivo Maior/imunologia , Feminino , Humanos , Inflamassomos/imunologia , Interleucina-1beta/sangue , Interleucina-1beta/imunologia , Masculino , Camundongos Endogâmicos C57BL , Pessoa de Meia-Idade , Proteína 3 que Contém Domínio de Pirina da Família NLR/imunologia
10.
Anesth Analg ; 123(5): 1143-1148, 2016 11.
Artigo em Inglês | MEDLINE | ID: mdl-27644061

RESUMO

BACKGROUND: Radiofrequency identification (RFID) detection systems are used to detect retained surgical sponges and may cause electromagnetic interference (EMI), altering intended function of cardiac pacing systems. Three pediatric patients requiring temporary pacing for postoperative atrioventricular block experienced transient inhibition of ventricular pacing during the use of RFID detection system. Bench testing was performed to evaluate the mechanism of pacemaker inhibition. METHODS: Impedance of temporary pacing wires was obtained using a pacing system analyzer. Temporary pacemakers (Medtronic 5388, Medtronic 5392, and Biotronik Reocor D) at nominal settings (VVI 120 bpm, output 10 mA) were attached at the ventricular terminal to temporary pacing wires and a resistor for sham impedance in physiologic range. An RFID detection system and wand (RF Assure, model 200) or mat was tested over wires. Induced current and voltages were recorded via an oscilloscope attached to lead terminals. Inhibition of pacing was determined for the following variables: distance from wires, sham impedance, and programmed sensitivity. RESULTS: In bench testing, the RFID system induced a stereotyped EMI signal in temporary pacing wires with peak root-mean-square voltage demonstrating an exponential decay relationship with increasing distance from pacing wires. Induced voltages overlapped with normal sensing range of temporary pacemakers, resulting in pacemaker inhibition at nominal settings (ventricular sensitivity 2.0 mV, distance from wand <23 cm). Increasing height, decreasing device sensitivity, or increasing sham impedance (at fixed sensitivity) attenuated EMI and inhibition for all 3 temporary pacemakers used and with the automated RFID detection mat in place of the wand. Programming pacemakers asynchronously prevented inhibition. CONCLUSIONS: Normal operation of RFID detection systems may cause inhibition of temporary pacing systems consistent with oversensing from EMI. Precaution should be taken, including considering pacing asynchronously to avoid effects of inhibition.


Assuntos
Bandagens , Estimulação Cardíaca Artificial , Procedimentos Cirúrgicos Cardíacos/instrumentação , Corpos Estranhos , Marca-Passo Artificial , Ondas de Rádio , Bandagens/efeitos adversos , Estimulação Cardíaca Artificial/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Pré-Escolar , Feminino , Corpos Estranhos/diagnóstico , Corpos Estranhos/prevenção & controle , Humanos , Marca-Passo Artificial/efeitos adversos , Ondas de Rádio/efeitos adversos , Fatores de Tempo
11.
J Neuroeng Rehabil ; 13(1): 54, 2016 06 10.
Artigo em Inglês | MEDLINE | ID: mdl-27283318

RESUMO

BACKGROUND: An above knee amputation can have a significant impact on gait, with substantial deviations in inter-leg symmetry, step length, hip exertion and upper body involvement even when using a current clinical standard of care prosthesis. These differences can produce gait that is less efficient and less comfortable, resulting in slower and shorter distance walking, particularly with long term use. METHODS: A robotic variable impedance prosthetic knee (VI Knee) was tested with five individuals (N = 5) with unilateral amputation above the knee at fixed speeds both above and below their normal walking speed. Subject gait was measured as they walked along an instrumented walkway via optical motion capture and force plates in the floor. Each subject's gait while using the VI Knee was compared to that while using their standard of care knee (OttoBock C-Leg). RESULTS: Significant differences (p < 0.05) in walking between the standard of care and variable impedance devices were seen in step length and hip range of motion symmetries, hip extension moment, knee power and torso lean angle. While using the VI Knee, several subjects demonstrated statistically significant improvements in gait, particularly in increased hip range of motion symmetry between affected and intact sides, greater prosthesis knee power and in reducing upper body involvement in the walking task by decreasing forward and affected side lean and reducing the pelvis-torso twist coupling. These changes to torso posture during gait also resulted in increased terminal stance hip flexion moment across subjects. Detriments to gait were also observed in that some subjects exhibited decreased step length symmetry while using the VI Knee compared to the C-Leg. CONCLUSIONS: The knee tested represents the potential to improve gait biomechanics and reduce upper body involvement in persons with above knee amputation compared to current standard of care devices. While using the VI Knee, subjects demonstrated statistically significant improvements in several aspects of gait though some were worsened while using the device. It is possible that these negative effects may be mitigated through longer term training and experience with the VI Knee. Given the demonstrated benefits and the potential to reduce or eliminate detriments through training, using a powered device like the VI Knee, particularly over an extended period of time, may help to improve walking performance and comfort.


Assuntos
Marcha/fisiologia , Articulação do Joelho/fisiologia , Prótese do Joelho , Robótica/instrumentação , Adulto , Amputação Cirúrgica , Fenômenos Biomecânicos , Impedância Elétrica , Feminino , Humanos , Masculino , Amplitude de Movimento Articular , Caminhada
12.
N Engl J Med ; 366(18): 1696-704, 2012 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-22443478

RESUMO

BACKGROUND: Transcatheter aortic-valve replacement (TAVR) is the recommended therapy for patients with severe aortic stenosis who are not suitable candidates for surgery. The outcomes beyond 1 year in such patients are not known. METHODS: We randomly assigned patients to transfemoral TAVR or to standard therapy (which often included balloon aortic valvuloplasty). Data on 2-year outcomes were analyzed. RESULTS: A total of 358 patients underwent randomization at 21 centers. The rates of death at 2 years were 43.3% in the TAVR group and 68.0% in the standard-therapy group (P<0.001), and the corresponding rates of cardiac death were 31.0% and 62.4% (P<0.001). The survival advantage associated with TAVR that was seen at 1 year remained significant among patients who survived beyond the first year (hazard ratio, 0.58; 95% confidence interval [CI], 0.36 to 0.92; P=0.02 with the use of the log-rank test). The rate of stroke was higher after TAVR than with standard therapy (13.8% vs. 5.5%, P=0.01), owing, in the first 30 days, to the occurrence of more ischemic events in the TAVR group (6.7% vs. 1.7%, P=0.02) and, beyond 30 days, to the occurrence of more hemorrhagic strokes in the TAVR group (2.2% vs. 0.6%, P=0.16). At 2 years, the rate of rehospitalization was 35.0% in the TAVR group and 72.5% in the standard-therapy group (P<0.001). TAVR, as compared with standard therapy, was also associated with improved functional status (P<0.001). The data suggest that the mortality benefit after TAVR may be limited to patients who do not have extensive coexisting conditions. Echocardiographic analysis showed a sustained increase in aortic-valve area and a decrease in aortic-valve gradient, with no worsening of paravalvular aortic regurgitation. CONCLUSIONS: Among appropriately selected patients with severe aortic stenosis who were not suitable candidates for surgery, TAVR reduced the rates of death and hospitalization, with a decrease in symptoms and an improvement in valve hemodynamics that were sustained at 2 years of follow-up. The presence of extensive coexisting conditions may attenuate the survival benefit of TAVR. (Funded by Edwards Lifesciences; ClinicalTrials.gov number, NCT00530894.).


Assuntos
Estenose da Valva Aórtica/terapia , Valva Aórtica/cirurgia , Cateterismo Cardíaco , Cateterismo , Implante de Prótese de Valva Cardíaca/métodos , Anticoagulantes/efeitos adversos , Anticoagulantes/uso terapêutico , Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/mortalidade , Cateterismo Cardíaco/efeitos adversos , Doenças Cardiovasculares/etiologia , Feminino , Seguimentos , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Hospitalização/estatística & dados numéricos , Humanos , Estimativa de Kaplan-Meier , Masculino , Inibidores da Agregação Plaquetária/efeitos adversos , Inibidores da Agregação Plaquetária/uso terapêutico , Falha de Prótese , Acidente Vascular Cerebral/etiologia , Ultrassonografia
13.
J Neuroeng Rehabil ; 12: 25, 2015 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-25881286

RESUMO

BACKGROUND: High cervical spinal cord injuries result in significant functional impairments and affect both the injured individual as well as their family and care givers. To help restore function to these individuals, multiple user interfaces are available to enable command and control of external devices. However, little work has been performed to assess the 3D performance of these interfaces. METHODS: We investigated the performance of eight human subjects in using three user interfaces (head orientation, EMG from muscles of the head and neck, and a three-axis joystick) to command the endpoint position of a multi-axis robotic arm within a 3D workspace to perform a novel out-to-center 3D Fitts' Law style task. Two of these interfaces (head orientation, EMG from muscles of the head and neck) could realistically be used by individuals with high tetraplegia, while the joystick was evaluated as a standard of high performance. Performance metrics were developed to assess the aspects of command source performance. Data were analyzed using a mixed model design ANOVA. Fixed effects were investigated between sources as well as for interactions between index of difficulty, command source, and the five performance measures used. A 5% threshold for statistical significance was used in the analysis. RESULTS: The performances of the three command interfaces were rather similar, though significant differences between command sources were observed. The apparent similarity is due in large part to the sequential command strategy (i.e., one dimension of movement at a time) typically adopted by the subjects. EMG-based commands were particularly pulsatile in nature. The use of sequential commands had a significant impact on each command source's performance for movements in two or three dimensions. CONCLUSIONS: While the sequential nature of the commands produced by the user did not fit with Fitts' Law, the other performance measures used were able to illustrate the properties of each command source. Though pulsatile, given the overall similarity between head orientation and the EMG interface, (which also could be readily included in a future implanted neuroprosthesis) the use of EMG as a command source for controlling an arm in 3D space is an attractive choice.


Assuntos
Eletromiografia/métodos , Movimentos da Cabeça , Músculos do Pescoço/fisiologia , Adulto , Algoritmos , Fenômenos Biomecânicos , Feminino , Humanos , Masculino , Orientação , Quadriplegia/fisiopatologia , Tempo de Reação , Robótica , Traumatismos da Medula Espinal/fisiopatologia , Interface Usuário-Computador , Adulto Jovem
14.
Biomed Eng Educ ; : 1-14, 2023 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-36686625

RESUMO

The COVID-19 pandemic exacerbated the already increasing challenge of establishing immersive, co-curricular activities for engineering students, particularly for biomedical-related activities. In the current work, we outline a strategy for co-curricular learning that leverages a private-public partnership in which methods for capacity-building have enabled mutually beneficial outcomes for both organizations. A contemporary issue for many non-profits is identifying effective ways to build capacity for consistent service delivery while at the same time embracing the volunteer activities of students; a challenge is that the lifecycle of a university student is often not aligned (much shorter) with the needs of the non-profit. The public-private partnership simultaneously meets the service motivation of students with the needs of the host. This paper includes two case studies that illustrate the implementation of the methods for capacity-building and related outcomes.

15.
medRxiv ; 2023 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-37131598

RESUMO

This study examined how race/ethnicity, sex/gender, and sexual orientation intersect to socially pattern depression among US adults. We used repeated, cross-sectional data from the 2015-2020 National Survey on Drug Use and Health (NSDUH; n=234,772) to conduct design-weighted multilevel analysis of individual heterogeneity and discriminatory accuracy (MAIHDA) for two outcomes: past-year and lifetime major depressive episode (MDE). With 42 intersectional groups constructed from seven race/ethnicity, two sex/gender, and three sexual orientation categories, we estimated group-specific prevalence and excess/reduced prevalence attributable to intersectional effects (i.e., two-way or higher interactions between identity variables). Models revealed heterogeneity between intersectional groups, with prevalence estimates ranging from 3.4-31.4% (past-year) and 6.7-47.4% (lifetime). Model main effects indicated that people who were Multiracial, White, women, gay/lesbian, or bisexual had greater odds of MDE. Additive effects of race/ethnicity, sex/gender, and sexual orientation explained most between-group variance; however, approximately 3% (past-year) and 12% (lifetime) were attributable to intersectional effects, with some groups experiencing excess/reduced prevalence. For both outcomes, sexual orientation main effects (42.9-54.0%) explained a greater proportion of between-group variance relative to race/ethnicity (10.0-17.1%) and sex/gender (7.5-7.9%). Notably, we extend MAIHDA to calculate nationally representative estimates to open future opportunities to quantify intersectionality with complex sample survey data.

16.
Circ Arrhythm Electrophysiol ; 16(4): e011447, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-37039017

RESUMO

BACKGROUND: Transcatheter Leadless Pacemakers (TLP) are a safe and effective option for adults with pacing indications. These devices may be an alternative in pediatric patients and patients with congenital heart disease for whom repeated sternotomies, thoracotomies, or transvenous systems are unfavorable. However, exemption of children from clinical trials has created uncertainty over the indications, efficacy, and safety of TLP in the pediatric population. The objectives of this study are to evaluate clinical indications, procedural characteristics, electrical performance, and outcomes of TLP implantation in children. METHODS: Retrospective data were collected from patients enrolled in the Pediatric and Congenital Electrophysiology Society TLP registry involving 15 centers. Patients ≤21 years of age who underwent Micra (Medtronic Inc, Minneapolis, MN) TLP implantation and had follow-up of ≥1 week were included in the study. RESULTS: The device was successfully implanted in 62 of 63 registry patients (98%) at a mean age of 15±4.1 years and included 20 (32%) patients with congenital heart disease. The mean body weight at TLP implantation was 55±19 kg and included 8 patients ≤8 years of age and ≤30 kg in weight. TLP was implanted by femoral (n=55, 87%) and internal jugular (n=8, 12.6%) venous approaches. During a mean follow-up period of 9.5±5.3 months, there were 10 (16%) complications including one cardiac perforation/pericardial effusion, one nonocclusive femoral venous thrombus, and one retrieval and replacement of TLP due to high thresholds. There were no deaths, TLP infections, or device embolizations. Electrical parameters, including capture thresholds, R wave sensing, and pacing impedances, remained stable. CONCLUSIONS: Initial results from the Pediatric and Congenital Electrophysiology Society TLP registry demonstrated a high level of successful Micra device implants via femoral and internal venous jugular approaches with stable electrical parameters and infrequent major complications. Long-term prospective data are needed to confirm the reproducibility of these initial findings.


Assuntos
Cardiopatias Congênitas , Marca-Passo Artificial , Adulto , Humanos , Criança , Adolescente , Adulto Jovem , Recém-Nascido , Estudos Prospectivos , Estudos Retrospectivos , Reprodutibilidade dos Testes , Resultado do Tratamento , Desenho de Equipamento , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Cardiopatias Congênitas/diagnóstico , Cardiopatias Congênitas/terapia
17.
J Invertebr Pathol ; 109(2): 187-93, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22085836

RESUMO

Nosema ceranae is a microsporidian parasite of the European honey bee, Apis mellifera, that is found worldwide and in multiple Apis spp.; however, little is known about the effects of N. ceranae on A. mellifera. Previous studies using spore counts suggest that there is no longer a seasonal cycle for N. ceranae and that it is found year round with little variation in infection intensity among months. Our goal was to determine whether infection levels differ in bees collected from different areas of the hive and if there may be seasonal differences in N. ceranae infections. A multiplex species-specific real-time PCR assay was used for the detection and quantification of N. ceranae. Colonies were sampled monthly from September 2009-2010 by collecting workers from honey supers, the fringe of the brood nest, and the brood nest. We found that all bees sampled were infected with N. ceranae and that there was no significant difference in infection levels among the different groups of bees sampled (P=0.74). However, significant differences in colony infection levels were found at different times of the year (P<0.01) with the highest levels in April-June and lower levels in the fall and winter. While our study was only performed for one year, it sheds light on the fact that there may be a seasonality to N. ceranae infections. Being able to predict future N. ceranae infections can be used to better advise beekeepers on N. ceranae management.


Assuntos
Criação de Abelhas , Abelhas/microbiologia , Microsporidiose/veterinária , Nosema/isolamento & purificação , Estações do Ano , Animais , Abelhas/fisiologia , Contagem de Colônia Microbiana , DNA Fúngico/análise , Interações Hospedeiro-Parasita , Microsporidiose/epidemiologia , Nosema/genética , Nosema/crescimento & desenvolvimento , Controle Biológico de Vetores , Virginia/epidemiologia
18.
Proc North Cent Sect ; 20222022 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-35603225

RESUMO

Biomedical engineering instructors teach the medical devices design theory and practice following the recommendations derived from the FDA regulations included in 21CFR820 and portraying it as less of a choice but the designer's obligation to uphold laws intended to reduce medical device design risk and protect the general public from defective goods. Although product liability cases are frequently adjudicated in a court of law, many students have only a vague notion of the link between design and product liability issues, and furthermore the important role that standards play in everyday design practice. To give real-life context for the connection between product liability and the benefits of using standards in design, we are aiming to develop moot court case studies that will offer engineering students the opportunity to investigate the viewpoint of various stakeholders and to bring arguments in support of their position. Our work-in-progress is part of a larger effort to reduce the barriers to standards adoption by engineering programs by creating a complete set of educational materials for educators based on specific case studies that foster consideration and use of standards in quality systems (ISO 13485:2016), and cyber-security in medical device design (ISO/IEEE 11073). Materials include lesson plans, content, and homework assignments that will be delivered as videos, tutorials, case study narratives, and Canvas modules. Our preliminary efforts have encouraged continuation of the development of content, though our efforts will benefit from other educator participation - this paper is a "Call to Action" for collaborators.

19.
Vaccine ; 40(27): 3752-3760, 2022 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-35599038

RESUMO

BACKGROUND: With continued challenges to the timeline for polio transmission interruption in Pakistan, including COVID-19, there is a risk of oral polio vaccine campaign fatigue among caregivers of young children. Renewed efforts to minimize oral polio vaccine acceptance erosion may be needed. This study examines the possible role of social norms in protecting against acceptance erosion and the role of vaccinators in promoting these social norms. METHODS: Data were analyzed from a poll conducted by local interview teams between February 23 and April 5, 2016, among 4,070 parents and other caregivers of children under age 5 living in areas at high-risk for polio transmission in Pakistan. The sample was drawn via a stratified multistage cluster design utilizing random route methods at the household level. We calculated the prevalence of subjective and descriptive social norms around vaccine acceptance; vaccine acceptance and commitment to vaccinate in future; and experiences and views of polio vaccinators across the population. We examined the relationship between these social norms and vaccination behaviors as well as the relationship between experiences with and views of vaccinators and social norms using uncontrolled comparisons (t-tests of proportion) and logistic repressions to control for demographics. RESULTS: Both descriptive and subjective positive social norms were associated with vaccine acceptance and future commitment. Positive experiences with and views of vaccinators (trust, perceived technical knowledge, compassion, and overall pleasantness of the interaction) were associated with both descriptive and subjective positive social norms. CONCLUSIONS: These data support the idea that positive social norms could be protective against erosion of oral polio vaccine acceptance and that positive experiences with, and views of, vaccinators could help promote these positive social norms. Creative community engagement efforts may be able to leverage positive experiences with vaccinators to help foster social norms and protect against the risk of acceptance erosion.


Assuntos
COVID-19 , Poliomielite , Cuidadores , Criança , Pré-Escolar , Humanos , Poliomielite/epidemiologia , Poliomielite/prevenção & controle , Vacina Antipólio Oral , Normas Sociais , Vacinação
20.
Brain ; 133(Pt 12): 3795-805, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-20817923

RESUMO

Professor J.A.N. Corsellis, whose life and work is recalled here, gained great insight into the meaning of morphological cerebral aberrations found in neuropsychiatric disease through exact neuropathological investigations of tissue specimens obtained from patients with distinct syndromes. He was a leading authority in the field. We have searched and compiled resources relating to J.A.N. Corsellis' life and work, including personal memories from colleagues and data from scientific publications. J.A.N. Corsellis made seminal contributions to the understanding of neuropsychiatric disease; his works substantially added to the understanding of the dementias, schizophrenia and the psychoses, and morphological sequelae of boxing. In seizure disorders, his name is linked to the first description of focal cortical dysplasia and limbic encephalitis, the pathology of status epilepticus and Ammon's horn sclerosis, and the systematic investigation of epilepsy surgery specimens in general. Both his life and work are closely linked to Runwell Hospital, Wickford, Essex and the Maudsley Hospital. During his professional life he established a large brain bank, now known as the Corsellis Collection. J.A.N. Corsellis had significant impact on neuroscience; many of his observations were groundbreaking and are still valid.


Assuntos
Epilepsia/história , Epilepsia/patologia , Neurociências/história , Transtornos Psicóticos/história , Transtornos Psicóticos/patologia , Córtex Cerebral/patologia , Alemanha , História do Século XX , Humanos , Londres , Livros de Texto como Assunto , Bancos de Tecidos/história , Reino Unido
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa